Top Banner
FOAMGLAS ® PERINSUL ® is an innovative product developed by PITTSBURGH CORNING to eliminate thermal bridges at joints within wall constructions. FOAMGLAS ® PERINSUL ® blocks, manufactured from FOAMGLAS ® , are designed to form an effective insulated joint between vertical wall insulation and horizontal floor or roof insulation. Possessing all the thermal properties for which FOAMGLAS ® is well proven, together with the exceptionally high compressive strength of FOAMGLAS ® , cold bridging is eliminated and structural integrity maintained. USE OF FOAMGLAS ® FOAMGLAS ® cellular glass insulation is guaranteed to maintain all its physical values for the lifetime of the building. It does not deteriorate with age and its thermal properties remain constant. FOAMGLAS ® is totally non-combustible and cannot contribute to a fire nor give off toxic fumes or smoke; it is also totally free from HCFC, HFA and pentane. Perimeter Insulation to Eliminate Thermal Bridges – New Build APPLICATIONS FOAMGLAS ® PERINSUL ® has an compressive strength at break point 2.5N/mm 2 and, when a safety factor is used, it typically has a load bearing capacity of 1 N/mm 2 without compression or deformation. It can therefore be installed at the base of structural walls in the following situations: – inner walls (block or brick) – outer walls (block or brick) – parapets – access points – support areas for roof trusses. PREPARATION AND INSTALLATION In order to provide its full load capacity FOAMGLAS ® PERINSUL ® is incorporated into the structure, laid into a soft mortar on a flat and level support with vertical joints tightly-butted. To achieve maximum adhesion, the blocks are moved to-and-fro in the mortar so that it is squeezed out on all sides. PERINSUL ® must be kept horizontal. The first layer of bricks or blocks on top of the FOAMGLAS ® PERINSUL ® must also distribute the load uniformly over their full surface. (Hollow or indented blocks should not be used for this layer unless they are inverted to present a flat face and the cavities are infilled with concrete). Should cutting be required, first remove a narrow strip of the facings with a sharp knife and then use a toughened saw for the PERINSUL ® . NB: FOAMGLAS ® PERINSUL ® blocks should not be tapped or struck with any tool. BUILDING REGULATIONS, Part L & J All FOAMGLAS ® systems meet the requirements of Building Regulations, with regard to air tightness of the building, the avoidance of cold bridging and sustainable construction. FOAMGLAS ® systems will continue to fully perform for the lifetime of the building. W5 WALLS Perinsul ® www.foamglas.co.uk FOAMGLAS ® PERINSUL ®
4

Foamglas - Insulating Blocks

Nov 27, 2014

Download

Documents

fromfrom
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Foamglas - Insulating Blocks

FOAMGLAS® PERINSUL® is an innovativeproduct developed by PITTSBURGH CORNINGto eliminate thermal bridges at joints withinwall constructions. FOAMGLAS® PERINSUL®

blocks, manufactured from FOAMGLAS®,are designed to form an effective insulatedjoint between vertical wall insulation andhorizontal floor or roof insulation. Possessingall the thermal properties for whichFOAMGLAS® is well proven, together withthe exceptionally high compressive strengthof FOAMGLAS®, cold bridging is eliminatedand structural integrity maintained.

USE OF FOAMGLAS®

FOAMGLAS® cellular glass insulation is guaranteedto maintain all its physical values for the lifetimeof the building. It does not deteriorate with ageand its thermal properties remain constant.FOAMGLAS® is totally non-combustible andcannot contribute to a fire nor give off toxic fumesor smoke; it is also totally free from HCFC, HFAand pentane.

Perimeter Insulation to EliminateThermal Bridges – New Build

APPLICATIONSFOAMGLAS® PERINSUL® has an compressivestrength at break point 2.5N/mm2 and, whena safety factor is used, it typically has a load bearingcapacity of 1 N/mm2 without compression ordeformation.It can therefore be installed at the base ofstructural walls in the following situations:– inner walls (block or brick)– outer walls (block or brick)– parapets– access points– support areas for roof trusses.

PREPARATION AND INSTALLATIONIn order to provide its full load capacityFOAMGLAS® PERINSUL® is incorporated into thestructure, laid into a soft mortar on a flat and levelsupport with vertical joints tightly-butted. Toachieve maximum adhesion, the blocks are movedto-and-fro in the mortar so that it is squeezed outon all sides. PERINSUL® must be kept horizontal.The first layer of bricks or blocks on top of theFOAMGLAS® PERINSUL® must also distribute theload uniformly over their full surface. (Hollow orindented blocks should not be used for this layerunless they are inverted to present a flat face andthe cavities are infilled with concrete). Shouldcutting be required, first remove a narrow strip ofthe facings with a sharp knife and then use atoughened saw for the PERINSUL®.NB: FOAMGLAS® PERINSUL® blocks shouldnot be tapped or struck with any tool.

BUILDING REGULATIONS,Part L & J

All FOAMGLAS® systems meet the requirements ofBuilding Regulations, with regard to air tightness of thebuilding, the avoidance of cold bridging and sustainableconstruction. FOAMGLAS® systems will continue to fullyperform for the lifetime of the building.

W5 WALLS

Perin

sul®

www.foamglas.co.uk

FOAMGLAS® PERINSUL®

Page 2: Foamglas - Insulating Blocks

-0,055-0,038-0,026

-0,067-0,043-0,028

0,8340,8470,855

0,8350,8470,854

a / bΨe

[W/m•K]Ψi,o Ψi,u[W/m•K]

fo / fu[–]

100 / 60

120 / 80

140 / 100

DIMENSIONS AND THERMAL

PERFORMANCEFOAMGLAS® PERINSUL® blocks are 450mm long,available in various thicknesses and widths asshown opposite.Blocks are bitumen coated on all faces.FOAMGLAS® PERINSUL® has a thermal conductivityof 0.055 W/mK at 10ºC.In a single leaf wall, a FOAMGLAS® PERINSUL® block110mm wide will exceed the requirements inPart L & J of UK Building Regulations and providea U-value of approximately 0.39 W/m2K.

PHYSICAL PROPERTIESCompressive Strength(average at breakpoint) : 2.5N/mm2

Load Bearing Capacity(safety factor applied): 1 N/mm2

Density: 220kg/m3(± 10%)Coefficient of thermalexpansion: 9 x 10-6/KThermal Conductivity(± 5%) at 10ºC: 0.055FireNon-combustible, no toxic fumesDimensional stabilityPerfectResistance to water-vapour transmissionµ = ∞28 dB for 100mm thicknessA safety factor is used in conjunction with thephysical properties of FOAMGLAS®; a factorof 2.5 or 3.1 is frequently used, a structuralengineer will provide your design requirements.

Ecologically FOAMGLAS® cellular glassmeets the most stringent demands foran environmentally sound material.In manufacturing, 66% post-consumerwaste glass is utilised, combined with amanufacturing process which minimisesenergy. The result is an insulation materialwhich provides high performancethroughout the lifetime of the building,through to its eventual disposal as aninert material or its re-use. FOAMGLAS®

is totally free from HCFC, HFA andpentane, exceeds the requirements ofthe Building Regulations and hasAgrément Certification.

FOAMGLAS® PERINSUL®

JUNCTION BASEMENT/GROUND FLOOR

JUNCTION OF EXTERNAL WALL/ GROUND

FLOOR BASEMENT

Optimised thermal bridge free construction. ThePERINSUL® block insulates between the wall andground floor slab.

Optimised thermal bridge free construction. ThePERINSUL® block is fitted under the external wall tostop the cold bridge.

0,020

0,062

0,092

0,0340,097

0,0320,121

0,0310,138

0,9310,882

0,9220,899

0,9290,909

a / cΨe

[W/m•K]Ψi

[W/m•K]f[–]

b = 175100 / 60120 / 80140 / 100

b = 240100 / 60120 / 80140 / 100

0,1180,1130,110

0,1270,1240,122

Ψ-VALUESThe calculation is based on the buildingelements; this gives a design value of theΨ-value (heat loss coefficient for thermalbridge (W/mK) with reference to the length ofthe element).Using FOAMGLAS®, Ψ-values can be achievedof zero or even negative values. Thecalculation follows the European regulationsfor thermal energy saving, taking intoconsideration the heat loss by thermal bridgesin an optimal way.

*215 block width is achieved by using 100mm+115 block close butted.Standard sizes available from stock to meet the requirements of both brickand block wall constructions

Widthmm

Thicknessmm

Lengthmm

100 65 450

115 65 450

140 65 450

100 100 450

115 100 450

140 100 450

FOAMGLAS® FOR WALLS

Page 3: Foamglas - Insulating Blocks

TYPICAL INSTALLATION DETAILS

This thermal image shows the major cold bridge and high thermal loss at thejunction between the floor slab and wall construction.

Fire tests carried out in Germany achieved Class F60, giving 60 minutes fireresistance in a wall construction. This was achieved without additional structuralelements being applied to the wall.

THERMAL IMAGING 60 MINUTE FIRE RESISTANCE

UNDER RING BEAM

UNDER EAVESUNDER PARAPETUPSTANDS

Double plywood coveringfixed by straps

GROUND FLOOR

Page 4: Foamglas - Insulating Blocks

Pittsburgh Corning (UK) Limited assumes no responsibility for errorsin, or misinterpretation of the information contained in this leaflet orin its use. Pittsburgh Corning (UK) Limited also retains the right toamend technical specifications without prior notice.

Pittsburgh Corning (UK) Limited63 Milford Road, ReadingBerkshire RG1 8LGTel: 0118 950 0655 Fax: 0118 950 9019email: [email protected]

FOAMGLAS® and PC are registered trademarks in the USA and othercountries. We reserve the rights of reproduction or translation, inwhole or part, in all countries including the CIS.

W5.10.08

For optimum speed of installation on the jobsite it is recommended that FOAMGLAS®

PERINSUL® blocks are placed adjacent to thearea of work.

1

3

5

2

4

6

1

A bed of mortar for the first course ofinsulation blocks is applied.

2

The height position of the PERINSUL® block isadjusted.

3

PERINSUL® blocks are laid with closely buttedend joints without mortar. Soft mortar isused above and below the block, using thesame technique as for bricks.

4

Fully waterproof, PERINSUL® forms a capillarybreak reducing the risk of moistureprogressing up the wall.

5

Building blocks or bricks are installed on topof the row of PERINSUL® as the wallconstruction progresses.

6

FOAMGLAS® FOR WALLS