FIRE ALARM SYSTEMVER.15.1

Page 2: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

AWEX brAnd

since the company was set up in 2002, its clearly defined mission have been modern top quality products and clients’ satisfaction. We offer a full range of emergency lighting devices meeting European norms and standards. Within the 14 years of our presence on the market, we have become the market leaders in the field - due to dedication, knowledge, financial means, cooperation with the best specialists, including some research centres, as well as due to investments into innovative undertakings. AWEX combines the most recent technologies, an experienced team of designers and engineers, top quality, the infallibility of equipment, a wide range of products, unique design, unlimited production capacity and flawless reputation confirmed by testimonials. Our best reward is our clients’ satisfaction and trust. We also enjoy a good reputation of independent experts. Awex has been awarded the „2006 Export Leader” prize for the achieved sales level as well as the „Gazele Biznesu („Business Gazelles”, awarded by Puls Biznesu magazine)” prize for being one of the most dynamically developing companies on the Polish market”.

PrOFESSIOnAL STAFF

We employ the best specialists in various fields. They continuously develop their skills through specialist trainings. The designing department ensures flexibility in terms of adapting to individual needs, and a team of highly qualified engineers guarantees permanent technical progress of the equipment offered. The application of modern means of information flow allows updating the offer and achieving products‘ functionality. The effective project management process makes it possible to build permanent and reliable relations with contractors.

InVESTMEnTS

We use the most recent world‘s technologies that guarantee quality, manufacturing accuracy, optimalisation of technological process and work ergonomics.We invest time and financial resources to make each step of constructing our products meet our clients‘ expectations.

rESEArCH

Our research and development department ensures that the offer is continuously updated in terms of the most recent developments in the field. That allows us to provide clients with modern, multifunctional and technologically advanced products.

WE CArE AbOUT THE EnVIrOnMEnT

We offer environmentally friendly products and our technological process meets high EU standards.

QUALITY WArrAnTY

In order to implement our company mission we have introduced the EN ISO 9001:2008 quality management system. Additionally, our TÜV NORD certificate guarantees top quality design, production process, assembling and servicing of the products

TABLE OF CONTENTS

Fire AlArm Control Unit 4

eSP remote Control PAnel 7

mUltiSenSor tS DeteCtor 8

mUltiSenSor tSC DeteCtor 10

roP21- mAnUAll CAll Point 12

WZ-4 StAtUS inDiCAtor 12

ASD-1 ACoUStiC/oPtiCAl inDiCAtor 13

ASD-2 ACoUStiC/oPtiCAl inDiCAtor 13

mio22 moDUle 14

GnC bASe 14

Page 3: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

Fire Alarm System Fire Alarm System

4 5

Fire Alarm Control Unit Fire Alarm Control Unit

FIrE ALArM COnTrOL UnIT

The control unit has been made up of modules, which make it easy to expand and service it. The basic version is equipped with power supply, control system, display and loop module. Expanding the control and adjusting it to your own needs can be done by installing and programming corresponding expansion cards

The control units are produced and sold in a couple of casings. The casing may or may not be equipped with a log printer (installed on the front door).

Maximum 4 expansion cards (e.g. a line module) can be connected to the fire alarm control unit. The unit consists of a control panel made up of LED indicators, some buttons, as well as 7-inch high resolution display. In the event of a system failure the basic system automatically switches to the backup system (redundancy) which carries on with all the functions as per EN 54-2 norm.

The display is available in several language versions.

The event log memory has the ability to store minimum 50,000 events. The memory and configuration can be stored on SD card. All saved events can viewed on a control panel and printed out by means of an inbuilt printer or viewed by means of the service tools and then printed from a PC. If more sensors need to be monitored, the system can be expanded by adding more interacting control units

411

209

753

Page 4: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

Fire Alarm System Fire Alarm System

6 7

Fire Alarm Control Unit ESP remote control panel

ROUTERSYSTEM ZARZĄDZANIA

BUDYNKIEM BMS

INTERNET PC

Fire alarm control units can be interconnected by means of the so called networking. The ESP remote control panel can also be connected to communication line in order to control each unit as well as to configure individual systems

The ESP panel allows to operate the control unit from a remote destination, by multiplying its interface and sending messages about: failures, blocking, testing and technical alarms. Due to the the use of a remote control panel, the central unit can be installed at a most topologically convenient location, whereas the panel can be installed close to the staff that manages the fire alarm system.

• multiplied interface• 7-inch touch screen• several access levels• available in several languages• access blocked by means of a key

The panel allows to confirm the indication of a fire alarm to the central unit and then delete the alarm indication. The panel controls its own systems and indicates their failures once they occur. It is possible to test the performance of alarm indicating elements of the terminal. The access to control elements and certain functions is variable and has been divided into access levels.

Networking the control units allow for designing the large, decentralized fire alarm systems used in any type and any size of buildings.

Optionally, the control units can be monitored via TCP/IP protocole. Remote access to the system can be obtained by means of a PC via dedicated software

RJ-45 and IP technologies make it possible to integrate the system with Building Management Systems (BMS), Security Management Systems (SMS) and visualization systems

265

185

54

Page 5: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

Fire Alarm System Fire Alarm System

8 9

MULTISENSOR TS DETECTOR MULTISENSOR TS DETECTOR

The TS detector is normally equipped with two detectors: the detector of temperature and smoke. The application of two sensors allows for swift and reliable detection of all types of fires. Depending on individual needs and installation site, one of the sensors may be switched off by means of a control panel (choosing an appropriate operation mode).

The algorithms have been applied in such a way so as to largely reduce the so called false alarms. The detector additionally monitors the level of dirt and informs the control unit once cleaning of the detector is required. The fact that the detectors are contaminated was also taken into account in a detection algorithm, thus increasing the certainty of fire detection.

The detector has been equipped with esthetic and low profile casing which guarantees quick and handy mounting. The detector base ensures loop continuity in spite of the absence of a detector. This allows to take all electrical measurements of the loop and maintain loop continuity while the detector is removed during service works.

Each detector has been equipped with a short circuit two-sided insulator which ensures continuous work of the loop in spite of short circuit on the loop. It also allows easy tracing of the failure

Size, including the base

•fire alarm switched on as a result of smokedetectionortemperatureincrease•sensitivitylevelandclassoftemperaturecompliantwithEN54norm•detectingthelevelofcontamination•adjustableresponsethreshold•compensatestheimpactofsurroundingconditions•smokeanalysissupportedbytemperatureanalysis•alarmnotifiedbyaLEDdiode•individualdetectorscanbedisconnected•integratedshort-circuitinsulator•contaminationlevelreadingoption•low-profilecasing•operatinginaddressablesystems

110

110

51

Smode

TSmode

Tmode

Detectoroperationmodes

Page 6: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

Fire Alarm System Fire Alarm System

10 11

MULTISENSOR TSC DETECTOR MULTISENSOR TSC DETECTOR

Our TSC detector is normally equipped with three sensors detecting temperature, smoke and carbon monoxide. The application of three sensors allows for quick and reliable detection of all types of fires as well detecting the risk of carbon monoxide poisoning. Depending on the need and location of a detector, one of three sensors can be disconnected by means of a control panel button.

The application of carbon monoxide detector is especially useful in rooms and zones where temporary smoke or sudden temperature increase may occur. The examples of such zones are underground garages or production areas. An additional carbon monoxide detector makes it possible to eliminate false alarms, improve the safety of people present in such rooms and decrease the risk of asphyxiation. The detector monitors the level of contamination and sends a cleaning request to the control unit. The contamination level is also taken into account in detection algorithm.

The detector comes in an esthetic, low-profile casing which allows for quick and handy installation. The base ensures loop continuity even in the event of detector’ s absence, which makes it possible to take all electrical measurements of the loop and allows to maintain loop continuity once the detector is dismantled during maintenance operations.Each detector has been equipped with a two-sided short-circuit insulator that secures continuous operation even in the event of short circuit. It also enables easy failure location.

•fire alarm switched on as a result of smokedetection, temperature increase or carbonmonoxidedetection•sensitivity level and class of temperature incompliancewithEN54norm•detectingthelevelofcontamination•adjustableresponsethreshold•compensatestheimpactofsurroundingconditions•smokeanalysissupportedbytheanalysisofcarbonmonoxideamountintheair•firealarmnotifiedbyaLEDdiode•individualdetectorscanbedisconnected•integratedshort-circuitinsulator•contaminationlevelreadingoption•low-profilecasing•operationinaddressablesystems

Size, including the base

110

110

51

SCmode

TSC

Detectoroperationmodes

TCmode

Page 7: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

Fire Alarm System Fire Alarm System

12 13

ROP21 - manuall call point ASD-1 acoustic/optical indicator

This ROP-21 manual call point is used to transfer information about fire alarm to a control unit by a person who noticed fire and who manually activated the call point. The manual call point can only be in operation with detector lines and loops controlled by the control unit line module.

The module is equipped with a ratchet mechanism allowing for reconverting the armed state without the necessity to replace any elements. The element is equipped with a two-sided short-circuit insulator

•integratedtwo-sidedshort-circuitinsulatorarmedstatereconversion•operationinaddressablesystems•notificationdiode

The indicator is used for acoustic and optical fire alarm indication in fire indication systems. It is intended for indoor rooms.

The indicator consists of two parts, the first of which is the appropriate indicator in an inflammable casing. It contains leads for connecting the supply voltage as well as pins which allow to choose the type ofsound. Y ou can choose between four acoustic signals. The other part, that is the base, is an element which allows to mount the indicator to a ceiling or a wall. The base is universal and it is applied in both indicators and multi-sensor detectors.

The indicator is used for acoustic and optical fire alarm indication. It is intended for indoor rooms and complies with EN 54-3 norm.

The indicator consists of two parts, the first of which is the appropriate indicator insidean inflammable casing. The casing is available in white or red color. The device can be directly connected to detection line module by means of a fire alarm control unit. The number of elements connected to the detection line module is determined by the indicator’s volume adjustment. The volume level and the type of sound signal are set directly in the fire alarm central unit. The other part, that is the base, is an element which allows to mount the indicator to a ceiling or a wall. The base is universal and it is applied in both indicators and multi-sensor detectors.

WZ-4 status indicator serves for repetition of optical fire alarm indication status of either one or more detectors. It can be installed in a base of one detector or a group of detectors. The indicator can be used either when the detector is not visible or when access to a room monitored by detectors is restricted e.g. suspended ceiling, conduits, maintenance rooms, hotel rooms, etc.

•compactsize•4notificationdiodes

WZ-4 status indicator ASD-2 acoustic/optical indicator

Indicator’s size including the base

Indicator’s size including the base

87

46

110

51

110

51

44

22

Page 8: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

Fire Alarm System Fire Alarm System

14 15

MIO22 module

The module has been designed to operate based on a detection loop and it functions as a controlling-steering element. The MIO22 loop module is equipped with 2 inputs and 2 potential-free outputs. The potential-free inputs can be either monitored or non-monitored (monitoring of the short circuit/opening of the wiring).

It is intended to activate fire alarm devices (e.g. indicators, smoke dampers, fireproof doors, etc.) via relay contacts of the fire alarm devices. The inputs serve, among others, to signal and monitor e.g. door limit switches, extinguishing systems, sprinklers. etc.

•2inputs/2outputs•addressable•easyinstallation•inputmonitoredforshortcircuitsorpowercuts•programaddressing•innershort-circuitinsulator•input/outputrecorddisplayedbymeansofdiods

The base serves to connect and install TS and TSC detectors as well as ASD-1 and ADS-2 indicators.

The base is equipped with a mechanism closing the detection circuit, due to which the line can be checked once a detector is not installed.

GNC base11

0

18

80

60120

Page 9: FIRE ALARM SYSTEM - Deutsche Messe AGdonar.messe.de/exhibitor/interschutz/2015/C267235/brochure-fire-system... · Fire Alarm System Fire Alarm System 6 7 Fire Alarm Control Unit ESP

DistributorAWEX SP. Z O. O. SPÓŁKA KOMAndYTOWAMasłomiąca, ul. Długa 3932-091 Michałowice, Poland tel.: (+48) 12 681 55 00, fax: (+48) 12 681 55 26e-mail: [email protected]