At FCI, we believe that customer satisfaction comes first, so we
offer you...
A Complete Line.We have the broadest selection of the highest
quality connectors, installation tools and accessories of anyone in
the industry.
A Dedicated Sales Force.FCI BURNDY Products employs 135 sales
and market specialists to solve your most complicated connector
problems.
On Time Delivery.FCI ships 99% of all stock orders within 24
hours.
Technical Assistance.Field experienced tech specialists are only
a phone call away.
For More Information Call
1-800-346-4175
Thank you for your interest in FCI BURNDY Products. All of our
1300 plus employees in North America are committed to YOU, our
VALUED CUSTOMER. For over 80 years, the BURNDY brand of connectors
and installation tooling has been synonymous with excellence,
service and value. We are excited to bring you some new BURNDY
products such as the BURNDYWeld line of EXOTHERMIC GROUNDING which
is shown in our Grounding section and our new line of 4PT TOOLS
which can be found in the Tooling section. Our black UNITAP
multiple tap connectors are shown at the end of the Mechanical
Section and the CLEAR H-TAP COVERS are in the Compression section.
I appreciate your continued support and look forward to exceeding
your expectations. Tom Robinson Vice President of Sales
MASTER INDEXA MECHANICAL bolts or allen head devices.......
....... Connectors secured by nuts, ............ B SMALL
COMPRESSION crimps ............. ................... Connectors
secured by indent or circumferential C MEDIUM AND LARGE COMPRESSION
...... .......... Connectors secured by indent or circumferential
crimps ........ D GROUNDING Grounding System and Mechanical
Grounding .... Irreversable Compression ......... .... E OVERHEAD
both Mechanical and Compression used on pole applications
.................. Power distribution connectors F WEJTAP systems
.......... Power actuated connection ... ............. G SUBSTATION
for tube cable and bus applications ... Power distribution
connectors ... ... H ALUMINUM WELDMENTS Extra High Voltage devices
............................................... .............. I
NETWORK UNDERGROUND ... ........................... Power
distribution connectors for underground applications J URD
UNDERGROUND applications ........ Power distribution connectors for
underground ...................... K CABLE TIES UNIRAP cable ties
......................... ........................... L HARDWARE of
various metals ............ .................. Nuts, Bolts and
Washers ........... M ACCESSORIES Terminal Blocks
................................................. Oxide Inhibitors
Markers and N TOOLING Hydraulic and Pneumatic ........ ...
Hand-Held, Mechanical ............ O REFERENCES General Information
................................................ Dies, Connectors
Charts and
MASTER INDEX........................... A ................
......................... ............... B
.....................................................................................
C ............. .................... D ................... .......
.... ....... E .......... ................. ....
.....................................................................................
F
.....................................................................................
G
.....................................................................................
H .......
...................................................................
I
.....................................................................................
J
.....................................................................................
K ................................
............................................... L
............................................. M
............................... ......... ......................
......................... N
.....................................................................................
O ...............................................
BURNDYMechanicalTABLE OF CONTENTSTypes KS, KS-3 & SC. . .
A-4 Type KSU . . . . . . . . . . . . A-5 Type KSA . . . . . . . . .
. . . A-6 Types KVS, KVSU . . . . . A-7 Types KVSW, KVS-A . . . A-8
Type QPX . . . . . . . . . . . . A-9 Type QPX-Y . . . . . . . . .
A-10 Type KPA . . . . . . . . . . . A-11 Type KPA-UP . . . . . . .
. A-12 Type KLU . . . . . . . . . . . A-13 Types KA, EA . . . . . .
. . A-14 Types BGBL, CL50-1 . . A-15 Types QA, QQA . . . . . . A-16
Types Q2A, Q3A. . . . . . A-17 Types QB, Q2B . . . . . . A-18 Types
QDA & QR . . . . . A-19 Types VT, E-C-G . . . . . . A-20 Types
K4A-U, KK4A, K11A-U, K21A, K22A . A-28 Type KAU-KIT . . . . . . .
A-29 Type AMS. . . . . . . . . . . A-30 Type AGSKIT . . . . . . . .
A-31 Type UGSKIT . . . . . . . . A-31 Type BISR-DB . . . . . . .
A-53 Type UGSKIT8 . . . . . . . A-32 Type 1PL . . . . . . . . . . .
A-54 Type UGS350ULDB . . . A-32 Type QGFL. . . . . . . . . . A-33
Type FCB . . . . . . . . . . . A-34 Types KPU-AC, UCU-AC . . . . .
. . . . . . A-35Complies with NFPA 78-86 Ordinary Structures.
Complies with NFPA 78-86 Heavy Duty Stacks (order: LD for Lead
Plating for Heavy Duty Stacks applications).
Types VA, VVA . . . . . . . A-21 Type HFB-P1 . . . . . . . .
A-22 Type HFB-N . . . . . . . . . A-23 Types KA-U, KKA-U . . . A-24
Type K2A-U . . . . . . . . . A-25 Types K3A-U, KK3A-U . . . . . . .
. . . . . . . A-26, A-27
Type BIPC . . . . . . . . . . A-36 SPEC-BLOK . . . . A-37, A-38
SPEC-BLOK PLATFORMS . . . . . . . A-39 Types 1300A, 1350A, 1500A .
. . A-41, A-42, A-43 Types BDA, BDB, BDC . . . . . . . . . A-44,
A-45, A-46, A-47, A-48 Types BIT, BISR . . . . . . A-49 Type BIBS .
. . . . . . . . . A-50 Type BIBD . . . . . . . . . . A-51 Types
BIBS-MT, BIBD-MT . . . . . . . . . . A-52
A-1
BURNDYMechanicalLIGHTNING PROTECTION INFO.Basic rules for
selection are: 1 Must be like material to the conductor (Flexitap
out due to steel bolts!). A-2 2. Two bolts to ground rod minimum. 3
Cable to cable connections can be anything one bolt, two bolt,
compression, etc. 4 Cable to steel structure must have 8 square
inch contact with steel. 5. Heavy duty stacks mechanical only. 6.
On all connectors with heavy duty stack rating, we must offer 1/16"
thick lead plating as an option. Reason is closest 25 ft. to stack
opening must use lead coated product. Complies with NFPA 78-86
Ordinary Structures. Complies with NFPA 78-86 Heavy Duty Stacks
(order: LD for Lead Plating for Heavy Duty Stack applications)
SPECIAL FEATURESOther features are also available for products
listed in price book such as undrilled or special drilling, 45 or
90 pad angles, belling for extra flexible cable, smooth or special
threaded studs, special labeling or packaging, extra long braid,
and nuclear certification. REFER TO FACTORY.
ALL OTHERS REFER TO FACTORY 1-800-346-4175
BURNDYMechanicalREVOLUTIONARY BURNDY DESIGN MEETS STRICT UL 486B
STANDARDS. . . and puts the bite on aluminum connections
forever!For use on all combinations Aluminum to aluminum Aluminum
to copper Copper to copper PatentedAvailable in sizes from #10
through 500 kcmil.
A-3
Unique bite and grip TRITAP SERVIT contact delivers safe,
long-term reliabilityeven without scratch brushing . . . without
oxide inhibiting compounds.
Spacer provides built-in separation to retard galvanic
corrosion.
Triangular edges bite into cable to break through surface oxides
...provide low contact resistance. ...produces gas tight seal.
Tin-plated contact surface inhibits oxide formation.
Special heat-treated hard, aluminum alloy.
Anti-galling, high efficiency threaded components result in high
contact force. Easily installed using standard, everyday
wrenches.
When used in NEC applications of insulated cables only.
BURNDYMechanicalTYPES KS & KS-3SERVITA-4
For Copper, CopperweldCompact, high strength, high copper alloy
SERVIT split-bolt has free-running threads and easy to grip wrench
flats. Highly resistant to season cracking and corrosion, the
SERVIT provides maximum pressure and assures a secure connection on
all combinations of run and tap conductors. Type KS-3 accommodates
3 maximum size conductors.
CONDUCTOR COPPER CATALOG NUMBERKS90 **KS15 **KS17 * KS17-3
**KS20 * KS20-3 **KS22 * KS22-3 **KS23 **KS25 **KS26 **KS27 **KS29
**KS31 **KS34 KS39 KS44
COPPERWELD MIN. TAP WITH MAX. RUN16 STR. 14 STR. 14 STR. 16 STR.
14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 8 SOL. 8
STR. 1/0 STR. 2/0 STR. 4/0 STR. 4/0 STR.
RECOMMENDED TIGHTENING TORQUE in-lb80
CROSS FLATS.50 .50 .63 .69 .75 .82 .94 1.05 1.36 1.36 1.70 1.82
2.31 2.56
L.85 .85 1.14 1.20 1.50 1.54 1.77 1.94 1.86 2.07 2.51 2.79 3.29
3.73
W.38 .38 .45 .51 .60 .62 .73 .82 1.17 1.17 1.41 1.48 1.94
2.19
RANGE FOR EQUAL RUN AND TAP12 STR. - 10 STR. 10 STR. - 8 STR. 8
STR. - 6 SOL. 8 STR. - 6 SOL. 8 STR. - 4 SOL. 8 STR. - 4 SOL. 6
STR. - 2 SOL. 6 STR. - 2 SOL. 6 STR. - 2 STR. 4 STR. - 1/0 STR. 2
STR. - 2/0 STR. 1 STR. - 3/0 STR. 1 STR. - 250 1/0 STR. - 350 2/0
STR. - 500 4/0 STR. - 750 300 - 1000
SOL.#10 #8 #6 #6 #4 #4 #2 #2 #1 2/0 3/0 4/0
MAXIMUM RUN AND TAP STR. TYPE A TYPE D 3 #12 3 #12 3 #10 3 #10 3
#8 3 #8 3 #7 3 #5 7 #7 7 #5 19 #8 19 #6 19 #5 8A 8A 6A 6A 4A 4A 3A
2A 9-1/2D 9-1/2D 8D 8D 6D 6D 5D 4D
165
275 385 500 650 825 1000 1100
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations.
See note page A-2 * Not UL or CSA Listed ** UL Rated for direct
burial.
TYPE SCSERVIT COVER HUG-A-BUGUsed indoors or outdoors, this
compact, onepiece plastic SERVIT cover saves time and material,
eliminates costly taping of splitbolts. Positive latch snaps easily
and quickly over connector, ideal for tight quarters.
Selfpositioning plastic fingers wrap around wires fully insulating
joint. UL Listed for 600 volt indoor application with type KS.
Three Covers accommodate a range of 6 SERVIT sizes through 2/0
Str.
CATALOG NUMBERSC4 SC2 SERVIT and cover combination can be
ordered as follows: CKS4 KS20 with cover CKS2/0 KS26 with cover For
other combinations, please contact factory. SC2/0
FOR USE WITHKS17, KS17-3, KS20 KSU17, KSU20 KS22, KS20-3, KS23,
KS22-3, KSA6, KSA4, KSU22, KSU23 KS25, KS26, KSA2, KSA 1/0 KSU25,
KSU26
BURNDYMechanicalTYPE KSUUNIVERSAL SERVIT For All Combinations of
Copper, Alum., ACSR, AAAC, 5005, and SteelTin-plated, high strength
copper alloy SERVIT with spacer. Spacer separates dissimilar
conductors and provides long contact length that prevents high
pressure point contacts between run and tap conductors. Use of
PENETROX joint compound recommended with Aluminum and ACSR.486A
Copper Only
A-5
CONDUCTOR MAXIMUM CONDUCTOR STEEL RECOMMENDED SOL. 3 STR. NOM
TIGHTENING BWG BWG DIA. TORQUE in-lb.8 6 4 8 6 4 5/32 7/32 1/4 5/16
3/8 7/16 1/2 1/2 5/8 165 275 275 385 385 500 650 650 825
RUN CATALOG CROSS NUMBER FIG. FLATKSU17 KSU20 KSU22 KSU23 KSU25
KSU26 KSU27 KSU29 KSU31 KSU34 2 2 2 2 2 2 1 1 1 1 .62 .69 .74 .81
.93 1.04 1.38 1.38 1.69 2.00
TAP ACSR AAAC 5005 COPPER & ALUMINUM ACSR AAAC 5005
L.92 1.05 1.25 1.48 1.77 1.93 2.34 2.50 2.88
W
COPPER & ALUMINUM
.42 12 SOL. - 6 SOL. 8 (6-1) 12 SOL. - 6 SOL. 8 (6-1) .48 10
SOL. - 4 SOL. 6 (6-1) 10 SOL. - 4 SOL. 6 (6-1) .57 10 SOL. - 2 SOL.
6 (6-1) - 4 (7-1) 10 SOL. - 2 SOL. 6 (6-1) - 4 (7-1) .59 8 STR. - 2
STR. 3 (6-1) - 2 (6-1) 8 SOL. - 2 STR. 6 (6-1) - 2 (6-1) .70 2 STR.
- 1/0 STR. 3 (6-1) - 1 (6-1) 10 STR. - 1/0 STR. 6 (6-1) - 1 (6-1)
.79 1/0 STR. - 2/0 STR. 1 (6-1) - 1/0 (6-1) 8 STR. - 2/0 STR. 6
(6-1) - 1/0 (6-1) 1.12 1 STR. - 3/0 STR. 1 (6-1) - 2/0 (6-1) 8 SOL.
- 3/0 STR. 8 (6-1) - 2/0 (6-1) 1.14 1 STR. - 250 2/0 (6-1) - 4/0
(6-1) 8 STR. - 250 6 (6-1) - 4/0 (6-1) 1.36 4/0 STR. - 350 3/0
(6-1) - 4/0 (6-1) 4 STR. - 350 4 (6-1) - 4/0 (6-1) 336 (30-7) - 477
3.12 1.47 400 - 500 2 STR. - 500 2 (6-1) - 477 (18-1) (18-1)
Accommodates compressed conductors within conductor ranges. See
note page A-2
BURNDYMechanicalTYPE KSATRITAP SERVITA-6
For All Combinations of Aluminum to Aluminum, Aluminum to Copper
and Copper to Copper, Aluminum Alloy Tin Plated PATENTED TRIANGULAR
PENETRATION TECHNOLOGY CONTACT Features and Benefits No scratch
brushing required. No oxide inhibitor required. Orients the
conductor. Provides maximum pressure and assures a secure
connection of run and tap conductors. Facilitates piercing the
aluminum conductor surface oxides. UL 486B listed, 90C rated.
Provides a low contact resistance. Provides equal coefficient of
expansion Inhibits the reformation of oxides by producing a
gas-tight seal. Provides improved retention of minimum to maximum
conductor combinations.
CATALOG CROSS NUMBER FLATS LKSA6 KSA4 KSA2 KSA 1/0 KSA 2/0 KSA
4/0 *KSA 350 *KSA 500 .75 .81 .94 1.00 1.12 1.49 1.69 2.00
W
ALUM. TO ALUM., ALUM. TO COPPER, COPPER TO COPPER CONDUCTORS
MAX. RUN TO MAX. TAP MIN. RUN TO MIN. TAP MAX. RUN TO MIN. TAP#6
STR. (.184) #4 STR. (.232) #2 STR. (.292) #1/0 STR. (.373) #2/0
STR. (.418) #6 STR. (.184) #4 STR. (.232) #2 STR. (.292) #1/0 STR.
(.373) #2/0 STR. (.418) #4/0 STR. (.528) #10 SOL. (.102) #10 SOL.
(.102) #8 SOL. (.129) #10 SOL. (.102) #6 SOL. (.169) #8 STR. (.146)
#2 STR. COMPACT #8 SOL. (.129) (.268) #2 STR. COMPACT #8 STR.
(.146) (.268) #2 STR. COMPACT #6 STR. (.184) (.268) #1/0 STR.
COMPACT #4 STR. (.232) (.336) 400 KCMIL #2 STR. COMPACT COMPACT
(.659) (.268) #6 STR. (.184) #4 STR. (.232) #2 STR. (.292) #1/0
STR. (.373) #2/0 STR. (.418) #4/0 STR. (.528) #350 KCMIL (.681)
#500 KCMIL (.813) #10 SOL. (.102) #10 SOL. (.102) #8 SOL. (.146) #8
SOL. (.129) #8 STR. (.146) #6 STR. (.184) #4 STR. (.232) #2 STR.
COMPACT (.268)
RECOMMENDED TIGHTENING TORQUE in-lb165 165 275 385 385 500 650
825
1.28 .56 1.38 .62 1.58 .69 1.92 .75 1.92 .88
2.54 1.13 #4/0 STR. (.528)
3.24 1.50 350 KCMIL (.681) 350 KCMIL (.681) 3.62 1.73 500 KCMIL
(.813) 500 KCMIL (.813)
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations. * Not CSA listed. ** No scratch brushing or
oxide inhibiting compounds required for insulated 90 C max. rated
conductor for N.E.C. applications.
BURNDYMechanicalTYPE KVSOKLIP Mechanical Connector For Copper
& CopperweldCompact, two-piece, high strength, high copper
alloy BURNDY OKLIP recommended for heavy duty connections. Neoprene
rings hold DURIUM bolts in place during installation. Installed
with ordinary wrench. A-7
CONDUCTOR COPPER CATALOG NUMBERKVS26 KVS28 KVS31 KVS34 KVS40
KVS44
RUN2 STR. - 2/0 STR. 1/0 STR. - 4/0 STR. 250 - 350 400 - 500 400
- 800 500 - 1000
TAP6 SOL. - 2/0 STR. 10 STR. - 4/0 STR. 10 STR. - 350 10 STR. -
500 3/0 STR - 800 3/0 STR. - 1000See note page A-2
SOL.3/0 4/0
COPPERWELD MAX. RUN AND TAP STR.7 #8 7 #6 19 #8 19 #6 19 #5
TYPE V V3/0 V250 V350
RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500 500
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations.
TYPE KVSUUNIVERSAL OKLIP Mechanical Connector For All
Combinations of Copper, Aluminum, ACSR, AAAC & 5005Compact,
high strength, tin plated copper alloy two-piece connector with
spacer and tinplated silicon bronze DURIUM hardware. Recommended
for heavy duty connections. Spacer separates dissimilar conductors
and provides long contact length. Neoprene ring prevents loss of
shorter bolt during installation. Longer peened bolt permits swivel
action for easier installation. Use of PENETROX joint compound
recommended with aluminum and ACSR.
CONDUCTOR RUN ACSR, AAAC, & 5005 RUN TAP COPPER COPPER ACSR,
SOL., SOL., AAAC, COPPERWELD STEEL COPPERWELD STEEL COPPER &
ALUM. & 5005 SOL., NOM. DIA. SOL., NOM. DIA. H6 STR. - 2/0 STR.
6 STR. - 4/0 STR. 6 - 350 4 - 500 4/0 - 800 4/0 - 1000 6 - 2/0 6 -
4/0 6 - 300 5 - 397.5 3/0 - 715.5 4/0 - 900 1 - 3/0 2/0 - 4/0 5/16
- 7/16 3/8 - 1/2 9/16 - 5/8 3/4 - 3/4 3/4 - 1 7/8 - 1-1/8 #6 - 3/0
#6 - 4/0 #6 - 4/0 #4 - 4/0
TAP
CATALOG NUMBER COPPER & ALUM.KVSU26 KVSU28 KVSU31 KVSU34
KVSU40 KVSU44
J
L
W
RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500
2 STR. - 2/0 STR. 3 - 2/0 1/0 STR. - 4/0 STR. 1/0 - 4/0 250 -
350 4/0 - 300 400 - 500 336.4 - 397.5 400 - 800 4/0 - 800 500 -
1000 4/0 - 1000
3/16 - 7/16 2 5/16 1 1-1/2 5/32 - 1/2 2-3/8 3/8 1-1/8 1-3/4 3/16
- 5/8 2-5/8 1/2 1-3/8 2-1/8 7/32 - 3/4 3 1/2 1-1/2 2-1/4 1/2 - 1
3-1/2 1/2 1-5/8 2-1/2 1/2 - 1-1/8 4 3/8 2 3
Accomodations compressed conductors within diameter range. See
note page A-2
BURNDYMechanicalTYPE KVSWOKLIPA-8
Mechanical Connector For Copper and Copperweld.Similiar to OKLIP
Type KVS except for a high copper alloy spacer that separates run
and tap conductors. Provides high contact pressure, confines
conductor strands, and assures vibration-proof connection. Longer
peened bolt, permits swivel action for easier installation. Silicon
bronze DURIUM hardware.
CATALOG NUMBERKVSW26 KVSW28 KVSW31 KVSW34 KVSW40 KVSW44See note
page A-2
CONDUCTOR RUN2 STR. - 2/0 STR. 1/0 STR. - 4/0 STR. 250 - 350 400
- 500 400 - 800 500 - 1000
TAP6 SOL. - 2/0 STR. 6 SOL. - 4/0 STR. 4 SOL. - 350 4 STR. - 500
4/0 - 800 250 - 1000
RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500 500
TYPE KVS-AALUMINUM OKLIP Mechanical Connector For All
Combinations of Copper, Aluminum, ACSR, AAAC and 5005Three-piece,
high-conductivity, non-copper bearing aluminum alloy connector with
thick spacer and aluminum hardware. Hardware in KVS26A and KVS28A
is stainless steel. Recommended for heavy duty dissimilar metal
applications. Spacer separates conductors and provides long contact
length. Belled entrances prevent chafing, permit easier assembly of
conductors. Longer peened bolt permits swivel action for easier
installation. Neoprene ring prevents loss of shorter bolt. PENETROX
joint compound recommended with aluminum and ACSR.
CONDUCTOR RUN CATALOG NUMBERKVS26A KVS28A KVS31A KVS34A KVS40A
KVS44A
TAP ACSR, AAAC, & 50054 - 2/0 1/0 - 4/0 4/0 - 336.4 336.4 -
397.5 336.4 - 715.5 397.5 - 900
COPPER, & ALUM.2 STR. - 2/0 STR. 1/0 STR. - 4/0 STR. 250 -
350 400 - 500 400 - 800 500 - 1000
COPPER, & ALUM.10 STR. - 2/0 STR. 10 STR. - 4/0 STR. 6 STR.
- 350 4 STR. - 500 3/0 STR. - 800 3/0 STR. - 1000
ACSR, AAAC & 50056 - 2/0 6 - 4/0 6 - 336.4 5 - 397.5 3/0 -
715.5 3/0 - 900
RECOMMENDED TIGHTENING TORQUE in-lb180 240 300 300 300 480
Accommodates compressed conductors within diameter range. See
note page A-2
THESE CONNECTORS CAN ACCOMMODATE ACSR CONDUCTORS OVER ARMOR ROD
WITHIN THE DIAMETER RANGE INDICATED. APPLICATION OVER ARMOR ROD
CONDUCTOR RANGE BY DIAMETER CATALOG MAX. RUN & NUMBER MIN.
RUN DIA. MIN. TAP DIA. TAP DIA.KVS26A KVS28A KVS31A KVS34A KVS40A
KVS44A .281 .360 .565 .728 .728 .806 .116 .116 .184 .216 .470 .470
.447 .564 .681 .814 1.036 1.162
H2-1/4 3 3-1/16 3-9/16 4-1/16 4-7/8
J5/16 3/8 1/2 1/2 1/2 5/8
L1-1/4 1-5/8 1-15/16 2-5/16 2-7/16 2-1/2
W1-5/8 2-1/16 2-7/16 2-5/8 2-7/8 3-1/8
BURNDYMechanicalTYPE QPXVERSITAP Parallel Clamp For Copper,
Copperweld, CopperweldCopperThe VERSITAP Type QPX is recommended
for Tee, Cross, Parallel, Butt and Tap connections. Range-taking,
only 10 connectors required to accommodate conductor sizes from #6
Str. to 1000 kcmil. Edges are rounded for easy taping. Made of high
strength, high-conductivity copper alloy and silicon bronze DURIUM
hardware. * For various configurations, see page A-10. A-9
Fig. 1
Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb 150 250 375
CATALOG NUMBERQPX2C2C QPX282C QPX2828 QPX342C QPX3428 QPX3434
QPX442C QPX4428 QPX4434 QPX4444
COPPER CONDUCTOR RUN TAP6 STR. - 2 STR. 1 STR. - 4/0 STR. 250 -
500 6 STR. - 2 STR. 6 STR. - 2 STR. 1 STR. - 4/0 STR. 6 STR. - 2
STR. 1 STR. - 4/0 STR. 250 - 500 6 STR. - 2 STR. 1 STR. - 4/0 STR.
250 - 500 500 - 1000
FIG. NO.
H1-1/2 2-1/16
J5/16 3/8 5/16 3/8 5/16 3/8
L1-5/16 1-13/16 1-3/8 1-3/4 2-1/16 1-3/8 1-13/16 2-1/16
2-5/8
W1-3/8 1-9/16 1-13/16 1-7/8 2-1/16 2-3/16 2-1/4 2-7/16
2-9/16
1
2-3/8 2-3/4 3 2-11/16 2-7/8 3-1/16 3-7/16
2 1 2
500 - 1000
500
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations. See note page A-2.
CONDUCTOR RUN CATALOG NUMBERQPX2C2C QPX282C QPX2828 QPX342C
QPX3428 QPX3434 QPX442C QPX4428 QPX4434 QPX4444
TAP COPPERWELD COPPER8A - 4A 3A - 3/0 V 3A - 3/0 V 4/0 EK
COPPERWELD5 SOL. - 3 #7 7 #9 - 7 #5 7 #9 - 7 #5 19 #9 - 19
#6
COPPERWELD5 SOL. - 3 #7 5 SOL. - 3 #7 7 #9 - 7 #5 5 SOL. - 3 #7
7 #9 - 7 #5 19 #9 - 19 #6 5 SOL. - 3 #7 7 #9 - 7 #5 19 #9 - 19 #6
19 #6
COPPERWELD COPPER8A - 4A 8A - 4A 3A - 3/0 V 8A - 4A 3A - 3/0 V
4/0 EK 8A - 4A 3A - 3/0 V 4/0 EK
19 #6
BURNDYMechanicalTYPE QPX-YUNIVERSAL VERSITAPA-10
Universal Parallel Clamp For Copper and AluminumHigh copper
alloy cast connector, tin-plated for use with copper or aluminum
cable. Makes parallel, tap, tee, cross or end-to-end connections.
Edges rounded for easy taping. PENETROX joint compound
recommended.
Fig. 1CONDUCTOR ALUMINUM OR COPPER RUN TAP6 STR. - 2 STR. 1/0
STR. - 4/0 STR. 1/0 STR. - 4/0 STR. 250 - 500 750 - 1000 6 STR. - 2
STR. 6 STR. - 2 STR. 1/0 STR. - 4/0 STR. 6 STR. - 2 STR. 1/0 STR. -
4/0 STR. 200 - 500 750 - 1000
Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb 150 250 375 500
CATALOG NUMBERQPX2C2C-Y QPX282C-Y QPX2828-Y QPX342C-Y QPX3428-Y
QPX3434-Y QPX4444-Y
FIG. NO.1 1 2 2
H1-5/8 1-7/8 2 2-1/4 2-1/2 2-7/8 3-7/8
J5/16 3/8 5/16 3/8 1/2
L1-1/2 2 1-1/2 2 2-1/2 3-1/2
W1-5/8 1-7/8 2-1/8 2-1/8 2-1/2 2-5/8 3-1/2
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7 4, 7-5 7-6 for smaller
conductor combinations. See note page A-2.
APPLICATION VARIATIONSPARALLEL TAP CROSS
TEE SPLICE
BURNDYMechanicalTYPE KPASCRULUG For Copper CableHigh copper
alloy tin-plated terminal for joining a wide range of cable to
equipment pads or terminal blocks. Especially good in light
industrial applications. The tongue and body are a one-piece
design. The pressure bar equalizes pressure over the conductor and
prevents the screw from cutting into the cable. A-11
Fig. 1STUD HOLE SIZE.10 1/4 5/16 3/8 1/2
Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb12 45 180 250 375
CATALOG NUMBERKPA8C KPA4C KPA25 KPA28 KPA34
WIRE RANGE8 STR. - 14 SOL. 14 SOL. - 4 STR. 4 STR. - 1/0 STR.
1/0 STR. - 4/0 STR. 4/0 STR. - 500 kcmil
FIG. NO.1 1 2 2 2
C.38 .50 .75 .97 1.38
D.47 .59 .81 1.12 1.38
H.72 .94 1.25 1.66 2.44
K.21 .27 .33 .40 .54
L.95 1.20 1.70 2.29 3.14
N.22 .30 .41 .53 .75
T.06 .06 .10 .13 .20
NOTE: For unplated version add UNPL suffix.
BURNDYMechanicalTYPE KPA-UPSCRULUGA-12
FOR COPPER CABLEHigh copper alloy terminal for joining a wide
range of cable to equipment pads or terminal blocks. Plain copper
finish.
Features and Benefits One piece design. Superior torque and pull
out performance. Convenient range taking design. Reduces catalog
numbers. One catalog number accommodates several conductor sizes.
High conductivity copper alloy. Long lasting, reliable contact.
Compact design. Easy to use. Slot Robertson screw, hex head, hex
socket bolt. No special installation tools required. Eliminates
over-torquing/potential conductor damage.
Fig. 1CATALOG WIRE NUMBER RANGEKPA8CUP KPA4CUP 14 SOL. 6 STR. 14
SOL. 4 STR.
Fig. 2
Fig. 3RECOMMENDED TIGHTENING TORQUE in-lb35 45
FIG. NO.1
C0.38 0.50
D0.51 0.71
H0.81 1.00
K0.20 0.28
STUD HOLE SIZE#10 1/4
L1.01 1.28
N0.24 0.33
T0.07 0.07
HARDWARE1/4 Dia. Slot Robertson 5/16 Dia. Slot Robertson
NOTE: For tin plating drop -UP suffix and add -TP suffix
(example: KPA4CTP). For use in grounding applications with a green
screw - contact factory. Listed for grounding per UL467.
BURNDYMechanicalTYPE KLUSCRULUG FOR COPPER CABLE OFFSET TONGUE
NON-PLATEDHigh copper alloy terminal with offset tongue for joining
a wide range of cable to equipment pads or bar. Easy to install
with screwdriver or wrench. Connector is reusable. Plain copper
finish. A-13
Features and Benefits Convenient range-taking design. Reduces
catalog numbers. One conductor accommodates several conductor
sizes. High conductivity copper alloy. Long lasting reliable
contact. Compact design. Easy to use. Reduces labor time. Slot
Robertson screw, hex head/hex socket bolt. No special installation
tools required. Eliminates over-torquing/potential conductor
damage.
Fig. 1CATALOG NUMBER CONDUCTOR
Fig. 2
Fig. 3STUD STRIP HOLE QUANTITY/ LENGTH SIZE PACKAGE (IN.) #6 #10
1/4 1/4 3/8 5/16 3/8 3/8 100 100 100 25 12 12 6 3 7/16 5/8 3/4
15/16 1 1-5/16 1-5/8 1-5/32
RECOMMENDED FIG. B C K L N T TIGHTENING NO. (MM/IN) (MM/IN)
(MM/IN) (MM/IN) (MM/IN) (MM/IN) TORQUE IN LBS. 3 6.4 .26 8.4 .33
11.8 .46 16.9 .63 18.0 .71 19.6 .77 25.2 1.0 29.6 1.16 8.0 .31 10.0
.39 12.0 .47 16.9 .63 19.0 .75 26.2 .99 26.2 .99 38.0 1.60 3.6 .14
6.0 .20 6.7 .26 6.5 .26 10.0 .39 8.5 .33 10.0 .39 10.0 .39 26.0
1.02 31.6 1.24 39.6 1.56 50.5 1.99 66.0 2.20 65.0 2.56 72.0 2.83
104.0 4.09 6.3 .21 5.6 .22 6.4 .25 10.8 .43 11.0 .43 13.0 .51 13.1
.52 23.0 .91 1.9 .07 1.8 .07 2.1 .08 2.7 .11 4.0 .16 3.1 .12 3.1
.12 4.5 .18 20 45 50 50 124 204 325 375
HARDWARE No. 8 - 32 Slotted Round Machine Screw 1/4 UNF Slotted
Set Screw 5/16 UNF Slotted Set Screw 3/8 UNF Slotted Set Screw 3/8
UNF Socket Set Screw 7/16 UNF Socket Set Screw 5/8 UNF Slotted Set
Screw 5/8 UNF Slotted Set Screw
KLU25 14 Sol. 1.63 (0.64) Dia. to KLU25TP 10 Sol. 2.60 (1.02)
Dia. CU KLU35 14 Sol. 1.63 (.0641) Dia. to KLU35TP 6 Str. 4.67
(.184) Dia. CU KLU70 8 Sol. 3.28 (.129) Dia. to KLU70TP 2 Str. 7.42
(.292) Dia. CU KLU125 2 Str. 7.42 (.292) Dia. to KLU125TP 1/0 Str.
9.44 (.372) Dia. CU KLU175 4 Str. 5.89 (.232) Dia. to KLU175TP 3/0
Str. 11.94 (.470) Dia. CU KLU225 2 Str. 7.42 (.292) Dia. to
KLU225TP 4/0 Str. 13.4 (.528) Dia. CU KLU300 1/0 Str. 9.44 (.372)
Dia. to KLU300TP 350 MCM 17.30 (.681) Dia. CU KLU400 1/0 Str. 9.44
(.372) Dia. to KLU400TP 500 MCM 207 (.813) Dia CU
2
1
2
NOTES: Suffix -TP on catalog number denotes tin plate (example:
KLU400TP). 2 Material: Copper alloy.
BURNDYMechanicalTYPE KAKA-LUGA-14
For Copper CableCompact, economical, high copper alloy terminal
for joining a wide range of cable to equipment pads or terminal
blocks.
Fig. 1CATALOG NUMBERKA8C KA4C KA25 KA25-2TC 38 KA28 KA34
Fig. 2STUD HOLE SIZE#10 1/4 3/8 3/8 3/8 1/2
Fig. 3RECOMMENDED TIGHTENING TORQUE in-lb25 45 200 200 275
375
CONDUCTOR14 SOL. - 8 STR. 14 SOL. - 4 STR. 4 STR. - 1/0 STR. 4
STR. - 1/0 STR. 1 STR. - 4/0 STR. 4/0 STR. - 500
FIG. NO.1 2 3 2
C3/8 9/16 3/4 3/4 15/16 1-3/8
H5/8 3/4 15/16 15/16 1-1/4 2-3/32
J#12 5/16 1/2 1/2 5/8 13/16
K7/32 9/32 27/64 27/64 27/64 9/16
L13/16 1-1/8 1-11/16 2-13/16 1-15/16 2-9/16
N3/16 1/4 3/8 3/8 7/16 9/16
T3/32 7/64 1/8 1/8 3/16 9/32
Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor sizes.
TYPE EAVERSILUG For Copper CableCompact, high copper alloy
terminal for joining a wide range of cable to equipment pads or
bar. Clamping element adjustable to several angles. One-wrench
installation.
CATALOG NUMBEREA2C EA25 EA28 EA28-2N EA34 EA34-2N
CONDUCTOR8 SOL. - 2 STR. 2 STR. - 1/0 STR. 1/0 STR. - 4/0 STR.
250 - 500
NO. OF HOLES IN PAD1 1 1 2 NEMA 1 2 NEMA
C13/16 7/8 1-1/16 1-3/8
D1-1/16 1-1/8 1-3/8 3-5/8 1-5/8 3-5/8
E 1-3/4 1-3/4
H1-3/8 1-7/16 1-3/4 2-1/4
K7/16
STUD HOLE SIZE3/8 3/8 3/8 1/2 1/2 1/2
L2-1/2 2-11/16 3-3/16 5-1/8 4 5-5/8
N13/32 7/16 17/32 5/8 13/16 5/8
T1/4 5/16 3/8
RECOMMENDED TIGHTENING TORQUE in-lb150 180 250 375
9/16
* N indicates NEMA standard stud holes. Listed torque values are
for maximum conductor sizes accommodated. Consult UL486 Tables 7-4,
7-5, 7-6 for smaller conductor sizes.
BURNDYMechanicalTYPE BGBLLAY-IN QIKLUG *UL LISTED 90 C, 600 VThe
Lay-In QIKLUG, Type BGBL is manufactured from high strength 6061-T6
aluminum, and is ideally suited for grounding and bonding
applications accommodating both copper and aluminum conductor sizes
#14 AWG to 250 kcmil. A-15
Fig. 1
Features and Benefits * UL 486B listed, AL9CU rated. For copper
and aluminum conductor combinations up to 90 C, 600 Volt
applications. UL Recognized for grounding and bonding. Ensures
reliability. Electro-tin plated. Provides low contact resistance.
Lay-in feature. Eases installation.
Fig. 2
DIMENSIONS CATALOG NUMBER*BGBL-4 BGBL-1/0 BGBL-250
FIG NO.1 1 2
CONDUCTOR RANGE4 - 14 AWG 1/0 - 14 AWG 250 kcmil - 6
C.39 [10] .63 [16] .88 [22]
D.62 [16] .80 [20] 1.18 [30]
E.48 [12] .83 [21] 1.00 [30]
H REF.79 [20] 1.16 [29] 1.72 [44]
J1/4 - 28 3/8 - 24 7/16 - 18
K DIA..22 [6] .28 [7] .28 [7]
L1.10 [28] 1.63 [41] 2.18 [55]
N.20 [5] .44 [11] .45 [11]
T.13 [3] .19 [5] .25 [6]
HEX SIZESLOT SLOT 7/32
NOTE: PEN-A PENETROX inhibitor is recommended for all aluminum
terminations.
TYPE CL50-1COPPER LAY-IN QIKLUG FOR COPPERThe Lay-In QIKLUG is
manufactured from high strength pure electrolytic copper to ensure
maximum strength and conductivity. UL467 Listed for direct burial
in earth or concrete. The open-faced design allows for fast lay-in
of the conductor without the need for cutting or breaking.
CATALOG NUMBERCL50-1
WIRE RANGE COPPER#14 - #4 CU
STUD HOLE#10
BURNDYMechanicalTYPES QA, QQAQIKLUGA-16
For Copper CableType QA heavy duty, compact, high copper alloy
terminal for joining a wide range of cable to equipment pads or
bar. Fast one-wrench installation. Type QQA heavy duty, high copper
alloy terminal for joining cable to equipment pads or bar. Twin
clamping elements secure joint vibration and flexing. One-wrench
installation.
Type QA
Type QQA
CATALOG NUMBER* CONDUCTOR TYPE QA TYPE QQA COMMERCIAL NAVYQA8C-B
QA8C-2B QA4C-B QA4C-2B QA1C-B QA1C-2B QA26-B QA26-2B QA28-B QA28-2B
QA28-2N* QA31-B QA31-2B QA31-2N* QA34-B QA34-2B QA34-4B QA34-2N*
QA40-B QA40-2N* QQA8C QQA8C-2 QQA4C QQA4C-2 QQA1C QQA1C-2 QQA26
QQA26-2 QQA28 QQA28-2N* QQA31 250 - 350 QQA31-2N* QQA34 400 - 500
QQA34-2N* QQA40-2N* QQA40-4N 600 - 800 650 - 800 400 - 500 250 -
350 14 SOL. - 8 STR. 8 STR. - 4 STR. 4 STR. - 1 STR. 4 - 14 23 - 40
50 - 75
NO. OF HOLES IN PAD1 2 1 2 1 2 1 2 1 2 2 NEMA 1 2 2 NEMA 1 2 4 2
NEMA 1 2 NEMA 4 NEMA 1 2 NEMA 4 NEMA 1 2 NEMA
C9/16
D
E&F
H
K
STUD HOLE SIZE#10 1/4 5/16 3/8
L
LL
N9/32 5/16 5/16 11/32
T5/32 3/16
RECOMMENDED TIGHTENING TORQUE in-lb75 110 150
5/8
1/0 STR - 2/0 STR. 100 - 125 3/0 STR. - 4/0 STR. 150 - 200
13/16 1
1-3/16 1-3/8 1-7/8 1-3/8 1-5/8 3 1-7/8
9/16 11/16 1-1/4 5/8 7/32 5/8 3/4 1-3/16 5/8 9/32 3/4 1 1-9/16
7/8 11/32 1 1-3/16 1-15/16 1 13/32 1-1/16 2 1 1-5/16 3-1/8 1-3/4
9/16 1-3/8 17/32 1-31/32 1 1-11/16 7/16 3 1-3/4 9/16 1-5/8 17/32 2
13/32 1 2 1-15/16 7/16 3-3/32 1-3/4 9/16 1-7/8 11/16 2-7/16 3 1-3/4
9/16 1-3/4 1-3/4 2-3/4 3-1/8 11/16 9/16 13/16 9/16
1/2 3/8 1/2 3/8 1/2 5/8 1/2 5/8 1/2 3/4 1/2
QA44-B QA44-2N* QQA44-2N QA44-4N* QQA44-4N* QA46-B QA46-2N*
850 - 1000 1100 - 1500
1000 1300
2 3 3 3-1/16 2-1/8 2-1/8 3
1-3/8 2-5/16 2 3 1-7/16 2-3/8 2 2-15/16 1-3/4 2-13/16 2-9/16
3-5/8 2 3-3/16 3 4-3/16 2-1/4 3-9/16 3-9/16 4-5/16 5-5/8 2-11/36
4-1/8 3-3/8 4-7/16 5-7/8 3-3/16 4-7/8 3-9/16 3-1/2 4-11/16 6-9/32
3-11/16 4-14/16 7-3/32 3-15/16 5 4-3/8 5-1/4 7-1/8
7/32 7/16 17/32 7/16 5/8 11/16 7/16 5/8 13/16 7/16 7/16 5/8
27/32 5/8 1 5/8 1-1/16 5/8 1/2 9/16 600 1/4 180 250
5/16
325
5/16
375
3/8 500
* N indicates NEMA standard stud holes. All 4N items See note
page A-2
BURNDYMechanicalTYPE Q2AQIKLUG For Copper CableCompact, high
copper alloy terminal for joining two cables to equipment pads or
bars. Each element accommodates a wide range of cable. One-wrench
installation. A-17
CATALOG NUMBER*Q2A1C-2 Q2A26-2N Q2A28-2N Q2A28-4N Q2A31-2N
Q2A31-4N Q2A34-2N Q2A34-4N Q2A40-2N Q2A40-4N Q2A44-4N Q2A46-4N
CONDUCTOR4 STR. - 1 STR. 1/0 STR. - 2/0 STR. 3/0 STR. - 4/0 STR.
250 - 350 400 - 500 600 - 800 850 - 1000 1100 - 1500
NO. OF HOLES IN PAD2 2 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 2 NEMA 4
NEMA 2 NEMA 4 NEMA 4 NEMA
C1-1/2 1-5/8 1-7/8 3 2-3/8 3 2-1/2 3 3 3-1/4 3-1/2
D1-7/8
E&F1 3/4
H1-1/16 1-3/16 1-3/8
K7/16
STUD HOLE SIZE3/8
L2-7/8 4-3/16 4-3/8 4-1/2
N7/16
T7/32 7/32 1/4 5/16
W1-13/16 1-15/16 1-15/16 2-1/8 2-1/8 3 3 3-3/4 3-3/4 4-11/32
4-11/32 5
RECOMMENDED TIGHTENING TORQUE in-lb 150 180 250 325 375 500
600
3-1/8 1-3/4
1-11/16 2 2-7/16 9/16 1/2
4-11/16 5 5-1/4 5-1/2
5/8
3/8 7/16 1/2 11/16
3-1/4
2-3/4 3-1/8
* N indicates NEMA standard stud holes. All 4N items See note
page A-2
TYPE Q3AQIKLUG For Copper CableCompact, high copper alloy
terminal for joining three cables to equipment pads or bar. Each
element accommodates a wide range of cable. One-wrench
installation.
CATALOG NUMBER*Q3A28-2N Q3A28-4N Q3A31-2N Q3A31-4N Q3A34-2N
Q3A34-4N Q3A40-4N Q3A44-4N Q3A46-4N
CONDUCTOR3/0 STR. - 4/0 STR. 250 - 350 400 - 500 600 - 800 850 -
1000 1100 - 1500
NO. OF HOLES IN PAD2 NEMA 4 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 4
NEMA 4 NEMA
C1-7/8 3 2-3/8 3 2-1/2 3 3-1/4 3-1/2
D
E&F
H1-3/8
K
STUD HOLE SIZE
L4-5/16 4-3/8 4-7/16
N
T1/4 5/16
W3-3/16 4-1/16 4-9/16 5-13/16 6-5/8 7-7/8
RECOMMENDED TIGHTENING TORQUE in-lb250 325 375 500 600
3-1/8 1-3/4
1-11/16 1-15/16 2-7/16 2-3/4 3-1/8 9/16 1/2
4-3/4 5 5-1/4 5-1/2
5/8
3/8 7/16 1/2 11/16
3-1/4
* N indicates NEMA standard stud holes.
BURNDYMechanicalTYPE QBQIKLUGA-18
For Copper CableCompact, high copper alloy side entrance
terminal for joining a range of cable at right angles to terminal
blocks. One-wrench installation.
CATALOG NUMBER*QB8C QB4C QB1C QB26 QB28 QB31-2N
CONDUCTOR14 SOL. - 8 STR. 8 STR. - 4 STR. 4 STR. - 1 STR. 1/0
STR. - 2/0 STR. 3/0 STR. - 4/0 STR. 250 - 350
NO. OF HOLES IN PAD1 1 1 1 1 2 NEMA
C9/16 11/16 13/16 1 13/16
D9/16 27/32 13/16 1 1-1/16 3-1/4
E 1-3/4
H7/8 13/16 1 1-1/32 1-5/16 1-11/16
K7/32 9/32 13/32 9/16
STUD HOLE SIZE#10 1/4 3/8 1/2
L1-1/8 1-3/8 1-1/2 1-13/16 2-1/16 4-1/2
N9/32 11/32 7/16 17/32 5/8
T5/32 1/4 7/32 1/4 5/16
RECOMMENDED TIGHTENING TORQUE in-lb 75 110 150 180 250 325
N indicates NEMA standard stud holes.
TYPE Q2BQIKLUG For Copper CableCompact, high copper alloy
terminal for joining two cables at right angles to a single
terminal block. Each element accommodates a range of cable.
One-wrench installation.
CATALOG NUMBER*Q2B28-2N Q2B31-2N Q2B40-4N
CONDUCTOR3/0 STR. - 4/0 STR. 250 - 350 600 - 800
NO. OF HOLES IN PAD2 NEMA 2 NEMA 4 NEMA
C1-7/8 2-3/8 3
D3-1/8 3-3/16 3-1/16
E&F1-3/4 1-11/16 1-3/8
H1-3/8 1-3/8 2-5/16
K9/16
STUD HOLE SIZE3/8 1/2 1
L5-3/16 5-7/8 6-11/16
N5/8
T1/4 5/16 7/16
RECOMMENDED TIGHTENING TORQUE in-lb250 325 500
N indicates NEMA standard stud holes. All 4N items See note page
A-2
BURNDYMechanicalTYPE QDAQIKLUG For Copper CableCompact, high
copper alloy terminal for joining a wide range of cable to
equipment studs. Provides low contact resistance when gripped
between two contact nuts. Onewrench installation. A-19
CATALOG NUMBERQDA8C QDA4C QDA1C QDA26 QDA28 QDA31 QDA34
QDA40
CONDUCTOR COMMERCIAL NAVY14 SOL. - 8 STR. 8 STR. - 4 STR. 4 STR.
- 1 STR. 1/0 STR. - 2/0 STR. 3/0 STR. - 4/0 STR. 250 - 350 400 -
500 600 - 800 3 - 14 23 - 40 50 - 75 100 - 125 150 - 200 250 - 350
400 - 500 650 - 800
C1 1-1/4 1-1/2 1-7/8 2-1/8
H11/16 3/4 1 1-3/16 1-5/16 1-11/16 2 2-5/16
K7/16 9/16 11/16 13/16 1-1/16
STUD HOLE SIZE3/8 1/2 5/8 3/4 1
L1-7/8 2-3/16 2-1/2 2-5/8 3 3-5/8 4-3/16
T3/16 7/32 9/32 5/16 3/8
RECOMMENDED TIGHTENING TORQUE in-lb75 110 150 180 250 325 375
500
TYPE QR QIKLINKSPLICE OR REDUCER For Copper Cable to CableHigh
copper alloy splicer/reducer for joining a range of cable end to
end. Neat, compact easy to tape installation. One-wrench
installation.
CATALOG NUMBERQR4C QR1C QR26 QR28 QR31 QR34 QR40See note page
A-2.
CONDUCTOR EITHER SIZE8 STR. - 4 STR. 4 STR. - 1 STR. 1/0 STR. -
2/0 STR. 3/0 STR. - 4/0 STR. 250 - 350 400 - 500 600 - 800
H3/4 1-1/16 1-3/16 1-3/8 1-11/16 1-15/16 2-7/16
L1-11/16 1-15/16 2-1/8 2-3/8 2-5/8 3-1/16 3-5/8
W5/8 11/16 13/16 1 1-1/4 1-7/16 1-7/8
RECOMMENDED TIGHTENING TORQUE in-lb110 150 180 250 325 375
500
BURNDYMechanicalTYPE VTVARITAP T-CONNECTORA-20
For Copper Cable to CableHigh copper alloy T-connector for cable
run, cable tap. V-bolt clamping elements accommodate large range of
cable and are particularly suited for extra flexible cable.
One-wrench installation.
CATALOG NUMBERVT2C2C VT2525 VT2825 VT2828 VT3025 VT3030 VT3425
VT3428 VT3430 VT3434 VT4040 VT4425 VT4428 VT4834 VT4844 VT4848
CONDUCTOR RUN8 SOL. - 2 STR. 6 SOL. - 1/0 STR. 1/0 STR. - 4/0
STR. 1/0 STR. - 300
TAP8 SOL. - 2 STR. 6 SOL. - 1/0 STR. 6 SOL. - 1/0 STR. 1/0 STR.
- 4/0 STR. 6 SOL. - 1/0 STR. 1/0 STR. - 300 6 SOL. - 1/0 STR. 1/0
STR. - 4/0 STR. 1/0 STR. - 300 300 - 500 500 - 800 6 SOL. - 1/0
STR. 1/0 STR. - 4/0 STR. 300 - 500 750 - 1000 1500 - 2000
H1-5/16 1-5/8 1-7/8
L2-5/16 2-5/8 3-1/8 3-1/16 3-3/8 3-5/16 3-11/16 3-1/2 3-5/8
3-3/4 4-1/2 4-5/16 4-1/8 5-1/4 5-3/4 6-1/4
W1-5/16 1-7/16 1-1/4 1-11/16 1-3/8 1-15/16 1-1/2 1-11/16 1-15/16
2-1/4 2-5/8 2 2 5 5 5
RECOMMENDED TIGHTENING TORQUE in-lb RUN TAP275 385 250 250 325
325 375 375 375 375 500 500 500 600 600 600 275 385 385 250 385 325
385 250 325 375 500 385 250 375 500 600
300 - 500 500 - 800 750 - 1000 1500 - 2000
2-5/16 2-9/16 2-7/8 4-1/4
See note page A-2
TYPE E-C-GTRANSFORMER TAP ADAPTER For CopperMulti-tap,
range-taking cast copper alloy connector designed to take 2, 3 or 4
conductors from a single secondary transformer outlet.
CATALOG NO. OF CONDUCTOR A NUMBER CONDUCTORS SIZE DIA.E2C34G1
E3C34G1 E4C34G1 2 3 4 1/0 SOL. - 500 .78
D
H
J
L
W3-1/2 5-1/4 6-7/8
RECOMMENDED TIGHTENING TORQUE in-lb480
3-3/4 2-7/8
1/2-13 6-1/4
BURNDYMechanicalTYPE VA, VVAVARILUG For Copper CableHigh copper
alloy terminal for joining a wide range of cable to equipment pads
or bar. Particularly suitable for use on extra flexible cable.
One-wrench installation. Type VVA, twin elements secure joint
against vibration and flexing. Particularly recommended for use on
extra flexible cables. One-wrench installation. A-21
Type VA
Type VVA
CATALOG NUMBER* TYPE VA TYPE VVAVA2C VA25 VA28 VA28-2N VA30
VA30-2N VA34 VA34-2N VA34-4N VA40 VA40-2N VA40-4N VVA2 VVA25 VVA28
VVA28-2N VVA30 VVA30-2N VVA34 VVA34-2N VVA34-4N VVA40 VVA40-2N
VVA40-4N
CONDUCTOR8 SOL. - 2 STR. 6 SOL. - 1/0 STR. 1/0 STR. - 4/0 STR.
1/0 STR. - 300 300 - 500
NO. OF HOLES IN PAD1 1 2 NEMA 1 2 NEMA 1 2 NEMA 4 NEMA 1 2 NEMA
4 NEMA
C13/16 7/8
D
E&F 1-3/4 1-3/4 1-3/4 1-3/4 1-3/4 1-3/4
H1-1/2 1-7/8 2-1/4 2-3/16 3-11/32
K7/16 7/16 9/16 7/16 9/16 11/16 9/16 9/16
STUD HOLE SIZE3/8 1/2 3/8 1/2 5/8 1/2
L
LL
N
T
RECOMMENDED TIGHTENING TORQUE in-lb275 385 250 325 375
500 - 800
1-1/4 1-5/16 1-1/2 1-1/16 3-1/2 1-5/8 1-1/8 3-9/16 2 1-3/8 3-5/8
3 3-5/8 2-5/16 1-5/8 3-5/8 3 2-5/8
2-7/8
2-3/4 4-1/16 2-7/8 4-5/16 2-7/8 4-1/8 4-15/16 6-3/6 3-1/4 4-5/8
5-3/16 6-9/16 3-13/16 5-5/16 5-3/8 6-7/8 5-3/8 6-7/8 4-1/2 6-3/8
5-13/16 7-11/16 5-13/16 7-11/16
13/32 1/4 7/16 17/32 5/8 5/16 5/8 5/8 13/16 5/8 5/8 3/8 15/16
5/8 5/8
500
N indicates NEMA standard stud holes. All 4N items See note page
A-2
BURNDYMechanicalTYPE HFB-P1A-22
BAR CLAMP ASSEMBLY COMPONENTS For Copper BarTo build your own
high strength clamp assembly for multiple flat bar using type
HFB-P1 bar clamps and clamping hardware, the following tables have
been provided. The clamp assembly eliminates the need for drilling
the flat bar and is used in indoor and outdoor applications.
BAR CLAMP BAR CATALOG RUN TAP NUMBER A AAHFB22P1 HFB33P1 HFB42P1
HFB44P1 HFB63P1 HFB66P1 HFB88P1 2.00 3.00 4.00 4.00 6.00 6.00 8.00
2.00 3.00 2.00 4.00 3.00 6.00 8.00
ONE CLAMP HALF J BOLT DIA. L3/8 3/8 3/8 1/2 1/2 5/8 3/4 4.38
4.38 5.75 5.75 7.75 8.12 10.50
W4.38 4.38 5.75 5.75 4.75 8.12 10.50
Z* * * * * * *
RECOMMENDED TIGHTENING TORQUE in-lb240 240 240 480 480 660
1990
*Z=Space between the bar clamp contact surfaces
COPPER BUS BAR WIDTH (INCHES) RUN-A TAP-AA2 3 4 4 6 6 8 2 3 2 4
3 6 8
BAR CLAMP ASSEMBLY COMPONENTS SILICON BRONZE CLAMPING HARDWARE
BAR CLAMP QTY. CAT. NO.2 2 2 2 2 2 2 HFB22P1 HFB33P1 HFB42P1
HFB44P1 HFB63P1 HFB66P1 HFB88P1
BOLTS QTY.4 4 4 4 4 4 4
NUTS CAT. NO.38 X (*) HEB 38 X (*) HEB 38 X (*) HEB 50 X (*) HEB
50 X (*) HEB 62 X (*) HEB 75 X (*) HEB
QTY.4 4 4 4 4 4 4
CAT. NO.38CHEN 38CHEN 38CHEN 50CHEN 50CHEN 62CHEN 75CHEN
SPLIT LOCK WASHERS QTY. CAT. NO.4 4 4 4 4 4 4 38SW 38SW 38SW
50SW 50SW 62SW 75SW
Ordered separately from BURNDY. * See table below when ordering
assembly clamping bolts to specify correct bolt length in Cat.
#.
CLAMP NUMBERHFB22P1 HFB33P1 HFB42P1 HFB44P1 HFB63P1 HFB66P1
HFB88P1
J BOLT DIA.3/8 (-16) 3/8 (-16) 3/8 (-16) 1/2 (-13) 1/2 (-13) 5/8
(-11) 3/4 (-10)
WHEN Z = 1.253.00 3.00 3.00 3.25 3.25 3.50 3.75
WHEN Z = 1.503.25 3.25 3.25 3.50 3.50 4.00 4.00
BOLT LENGTH WHEN WHEN Z = 1.75 Z = 2.003.50 3.50 3.50 3.75 3.75
4.00 4.50 4.00 4.00 4.00 4.00 4.00 4.50 4.50
WHEN Z = 2.254.00 4.00 4.00 4.50 4.50 4.50 5.00
WHEN Z = 2.504.50 4.50 4.50 4.50 4.50 5.00 5.00
WHEN Z = 2.754.50 4.50 4.50 5.00 5.00 5.00 5.50
WHEN Z = 3.005.00 5.00 5.00 5.00 5.00 5.50 5.50
NOTE: When ordering assembly bolts specify correct bolt length
in catalog number as indicated in table.
BURNDYMechanicalTYPE HFB-NBAR CLAMP TAP PAD ADAPTER For Copper
BarHigh conductivity copper, tap pad adapter provides a NEMA
drilled contact pad when assembled to the HFB-P1 clamps. Tap
connections can be made from copper bus bar(s) without drilling, by
bolting standard mechanical or compression terminal pads directly
to the pre-drilled tap pad A-23
Fig. 1 Fig. 2CATALOG NUMBERHFB33-4N HFB44-4N HFB66-6N
FIG. NO.1 1 2
A-C3.00 4.00 6.00
E&F1.75 1.75 1.75
L7.00 9.12 11.31
N.62 1.12 1.12
USE WITH H CLAMP CATALOG NUMBER HFB33P1 HFB44P1 HFB66P1
H Clamp (two required per assembly) and hardware (asshown) not
included with bar clamp tap pad, order separately.
BURNDYMechanicalTYPES KA-U, KKA-UUNIVERSAL TERMINALA-24
(One Conductor) For Aluminum and Copper ConductorsThese
dual-rated one-conductor lugs are constructed from high strength
aluminum alloy and electro tin-plated to provide low contact
resistance.
Fig. 1
Fig. 2
AL9CU
Fig. 3
Fig. 4
CATALOG NUMBER*KA6U KA2U KA25U KA26U KA29U KA30U KA31U KA34U
KA36U KA40U KA44U KKA31U-2N KA36U-2N KA40U-2N KA44U-2N
FIG. NO.1 1 1 2 2 2 2 2 2 2 2 3 4 4 4
WIRE RANGE ALUMINUM OR COPPER14 STR. - 6 STR. 14 STR. - 2 STR.
14 STR. - 1/0 STR. 6 STR. - 2/0 STR. 6 STR. - 250 6 STR. - 300 6
STR. - 350 4 STR. - 500 2 STR. - 600 300 - 800 500 - 1000 6 STR. -
350 2 STR. - 600 300 - 800 500 - 1000
STUD HOLE SIZE1/4
D.63 .63 .81 .81 .94 .94 1.03 1.50 1.72 1.69 1.69 3.16 3.22 3.03
3.03
L1.06 1.16 1.50 1.47 2.00 2.00 2.25 2.81 3.19 3.38 3.38 5.50
4.69 4.75 4.75
DIMENSIONS ** N W E.25 .31 .44 .47 .50 .50 .88 .88 .78 .88 .88
.63 .63 .63 .63 .50 .50 .63 .63 1.00 1.00 1.13 1.51 1.50 1.75 1.75
1.25 1.50 1.75 1.75 1.75 1.75 1.75 1.75
T.09 .10 .19 .19 .25 .25 .25 .31 .44 .50 .50 .38 .44 .50 .50
** H.50 .55 .80 .80 1.13 1.12 1.25 1.58 1.56 1.94 1.94 1.50 1.57
1.94 1.94
RECOMMENDED TIGHTENING TORQUE in-lb45 50 50 120 275 275 375 500
500 500 600 375 500 500 600
5/16 3/8 1/2
1/2
* "N" indicates NEMA standard stud holes. Listed torque values
are for maximum conductor sizes accommodated. Consult UL486 Tables
7-4, 7-5, 7-6 for smaller conductor sizes. ** Maximum
dimension.
BURNDYMechanicalTYPE K2A-UUNIVERSAL TERMINAL (Two Conductor) For
Aluminum and Copper ConductorsThese dual-rated two-conductor lugs
are constructed from high strength aluminum alloy and electro
tin-plated to provide low contact resistance. A-25
Fig. 1
Fig. 2
Fig. 3
CATALOG NUMBER*K2A25U K2A26U K2A29U K2A31U K2A36U K2A40U K2A44U
K2A31U-2N K2A36U-2N K2A40U-2N K2A44U-2N
FIG. NO.1 2 2 2 2 2 2 3 3 3 3
WIRE RANGE ALUMINUM OR COPPERTwo: 14 STR. - 1/0 STR. Two: 14
STR. - 2/0 STR. Two: 6 STR. - 250 Two: 4 STR. - 350 Two: 2 STR. -
600 Two: 300 - 800 Two: 500 - 1000 Two: 6 STR. - 350 Two: 2 STR. -
600 Two: 300 - 800 Two: 500 - 1000
STUD HOLE SIZE1/4 3/8 1/2 5/8
D.81 .81 1.50 1.69 1.75 1.66 1.66 3.00 3.22 3.03 3.03
L1.47 1.47 2.56 2.88 3.20 3.38 3.50 4.50 4.69 4.75 4.75
DIMENSIONS ** N W E.44 .44 .50 .88 .63 .88 .88 .63 .63 .63 .63
1.13 1.25 1.66 1.94 2.41 3.19 3.52 2.31 2.41 3.19 3.19 1.75 1.75
1.75 1.75
T.19 .19 .25 .25 .44 .50 .50 .31 .44 .50 .50
** H.79 .79 1.20 1.25 1.58 1.94 1.94 1.38 1.56 1.94 1.94
RECOMMENDED TIGHTENING TORQUE in-lb50 50 275 275 375 375 375 275
375 375 375
1/2
* "N" indicates NEMA standard stud holes. Listed torque values
are for maximum conductor sizes accommodated. Consult UL486 Tables
7-4, 7-5, 7-6 for smaller conductor sizes. ** Maximum
dimension.
BURNDYMechanicalTYPES K3A-U, KK3A-UUNIVERSAL TERMINALA-26
(Three Conductor) For Aluminum and Copper ConductorsDual-rated
three-conductor lugs are constructed from high strength aluminum
alloy and electro tin-plated to provide low contact resistance.
Fig. 1
Fig. 2
AL9CU
Fig. 3
CATALOG NUMBER*K3A2U-2* K3A25U-2* K3A26U-2N K3A27U-2N K3A29U-2N
K3A31U-2N K3A36U-2N KK3A36U-2N KK3A40U-2N KK3A44U-2N
FIG. NO.1 1 3 3 3 3 3 2 2 2
WIRE RANGE ALUMINUM OR COPPERThree: 14 STR. - 2 STR. Three: 14
STR. - 1/0 STR. Three: 14 STR. - 2/0 STR. Three: 6 STR. - 3/0 STR.
Three: 6 STR. - 250 Three: 6 STR. - 350 Three: 2 STR. - 600 Three:
2 STR. - 600 Three: 300 - 800 Three: 500 - 1000
K11/32 7/16
STUD HOLE SIZE5/16 3/8
D1.63 2.09 3.06 3.00 3.00 3.00 3.22 3.00 3.03 3.34
L2.19 2.91 3.75 3.88 4.00 4.31 4.69 5.63 5.69 6.19
DIMENSIONS N W E.34 .34 .63 .63 .63 .63 .63 .56 .63 .63 1.59
1.94 1.95 2.81 2.81 3.00 3.63 4.22 4.81 4.75 .88 1.00
T.19 .25 .19 .31 .31 .31 .44 .44 .50 .56
H.62 .88 1.79 1.12 1.19 1.38 1.56 1.69 1.94 1.88
RECOMMENDED TIGHTENING TORQUE in-lb50
275
9/16
1/2
1.75
375
* Slotted screw. ** N indicates NEMA standard stud holes. Listed
torque values are for maximum conductor sizes accommodated. Consult
UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N
items See note page A-2
BURNDYMechanicalTYPES K3A-U, KK3A-U(Continued)A-27
AL9CU
Fig. 1
Fig. 2
Fig. 3
Fig. 4
CATALOG NUMBER**K3A2U-4* K3A25U-4* K3A27U-4N K3A29U-4N K3A31U-4N
K3A36U-4N K3A40U-4N KK3A36U-4N KK3A40U-4N KK3A44U-4N
FIG. NO.3 3 3 3 3 3 3 4 4 4
WIRE RANGE ALUMINUM OR COPPERThree: 14 STR. - 2 STR. Three: 14
STR. - 1/0 STR. Three: 6 STR. - 3/0 STR. Three: 6 STR. - 250 Three:
6 STR. - 350 Three: 2 STR. - 600 Three: 300 - 800 Three: 2 STR. -
600 Three: 350 - 800 Three: 500 - 1000
K11/32 7/16
STUD HOLE SIZE5/16 3/8
D1.63 2.09 3.00 3.00 3.00 3.22 3.03 3.00 3.34 3.34
L2.19 2.91 3.88 4.00 4.31 4.69 4.75 5.63 6.19 6.19
DIMENSIONS N W E.34 .34 1.59 1.94 2.81 2.81 3.00 3.63 4.81 4.22
5.34 4.75 .88 1.00
T.19 .25 .31 .31 .31 .44 .50 .44 .56 .56
H.62 .88 1.12 1.19 1.38 1.56 1.94 1.69 1.88 1.88
RECOMMENDED TIGHTENING TORQUE in-lb50 275
9/16
1/2
.63
1.75
375 275 375
* Slotted screw ** N indicates NEMA standard stud holes. Listed
torque values are for maximum conductor sizes accommodated. Consult
UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N
items See note page A-2
BURNDYMechanicalTYPES K4A-U, KK4A-UUNIVERSAL TERMINALA-28
(Four Conductor) For Aluminum and Copper ConductorsThese
dual-rated four conductor lugs are constructed from high strength
aluminum alloy and electro tin-plated to provide low contact
resistance.
Fig. 1
Fig. 2
AL9CU
CATALOG NUMBER*K4A29U-4N K4A31U-4N KK4A36U-4N KK4A40U-4N
FIG. NO.1 1 2 2
WIRE RANGE ALUMINUM OR COPPERFour: 6 STR. - 250 Four: 6 STR. -
350 Four: 2 STR. - 600 Four: 300 - 800
STUD HOLE SIZE1/2
D3 3 3.34 3
L4 4.31 5.63 6.19
DIMENSIONS N W E.63 3.69 5.04 5 6 1.75
T.31 .31 .44 .56
H1.19 1.38 1.69 1.88
RECOMMENDED TIGHTENING TORQUE in-lb275 375
* N indicates NEMA standard stud holes. All 4N items See note
page A-2
TYPES K11A-U, K21A-U, K22A-UUNIVERSAL TERMINAL For Aluminum and
Copper ConductorsDual-rated panelboard lugs are constructed from
high strength extruded aluminum alloy and electro tin-plated to
provide low contact resistance.
Fig. 2 Fig. 1
Fig. 3
Fig. 4
Fig. 5
AL9CU
CATALOG NUMBER*K11A30U* K11A34U-2 K11A36U-2 K21A36U-2 K22A36U-2
K11A39U-2 K22A39U-2
FIG. NO.1 2 3 4 5 3 5
WIRE RANGE ALUMINUM OR COPPERTwo: 6 STR. - 300 Two: 4/0 STR. -
500 Two: 2 STR. - 600 Three: 2 STR. - 600 Four: 2 STR. - 600 Two:
1/0 STR. - 750 Four: 1/0 STR. - 750
STUD HOLE SIZE5/16 1/4
D.94
L3.00 2.91
DIMENSIONS N W E.47 .25 1.00 1.44 1.50 2.50 2.50 1.69 3.06
.69
T.31 .63
H2.00 2.38
RECOMMENDED TIGHTENING TORQUE in-lb275
3/8
2.31
4.91
.38
1.38
.75
3.00
375
* Not CSA Listed. Listed torque values are for maximum conductor
sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor sizes.
BURNDYMechanicalTYPE KAU-KITTRANSFORMER LUG KITA-29 These
dual-rated lugs are constructed from high strength aluminum alloy
and electro tinplated to provide low contact resistance. Lugs and
mounting hardware packaged together in these kits.
Features and Benefits UL listed AL9CU dual rated set screw
terminals and CSA certified. Ensure the transformer feeders and
taps are terminated properly. Plated steel cap screws and hex nuts
with captive conical washers or individual Belleville washers.
Terminal to bus connections are made using proper hardware
resulting in true torque to pressure performance. Compensates for
dissimilar metal expansion and contraction.
Hardware packed in plastic bag. No lost hardware prior to
installation. Larger 800 kcmil lugs in KIT3 and KIT4. Accommodates
common 750 kcmil tap conductors in larger transformers.
TERMINALS CATALOG TRANSFORMER CATALOG NUMBER KVA RATING QTY.
NUMBERKAU-KIT1 KAU-KIT2 KAU-KIT3 KAU-KIT4 15 - 37.5 15 - 45 50 - 75
75 - 112.5 100 - 167 150 - 300 400 - 500 1 3 1 3 1 3 3 8 4 12 6 7
15 KA2U KA29U KA29U K2A31U K2A40U K2A40U
WIRE RANGE ALUMINUM OR COPPER#14 - 2 #6 - 250 #6 - 250 #6 - 350
300 - 800 300 - 800
QTY.8 8 8 5 6 7 4
BOLT SIZE1/4-20 3/4 HH
HARDWARE QTY. NUT8 16 11 11 1/4 1/4 20 HN 20 HN
QTY. 22 11 22 11
WASHERCaptive to Nut Captive to Nut 1/2 FW 1/2 Belleville 1/2 FW
1/2 Belleville
1/4-20 3/4 HH 1/4-20 2 HH 1/2-13 3 HH 1/2-13 2-1/2 HH 1/2-13 2
1/2-13 2-1/2
1/2-13 HN 1/2-13 HN
BURNDYMechanicalTYPE AMSA-30
DUAL RATED SPLICER/REDUCER For Copper and Aluminum CableAll
splicer/reducers are dual rated for use with aluminum and copper
conductors and are constructed from high strength, tin plated
aluminum. PENTROX oxide inhibiting joint compounds are recommended
for all aluminum applications.
Features and Benefits All connectors are tin-plated. Provide low
contact resistance and prevents galvanic corrosion. Connectors
feature rounded bottoms. Facilitates taping. Solid center barrier.
Prevents contact of dissimilar metals. Large screw diameters.
Ensures greater surface contact with wires for maximum pullout
force. Large cable ranges. Each splice is also an effective
reducing connector.
CATALOG NUMBERAMS-2* AMS-0* AMS-4/0 AMS-250 AMS-350 AMS-500
AMS-750 AMS-1000
WIRE RANGE MAX. MIN.2 1/0 4/0 250 350 500 750 1000 14 8 6 6 6
3/0 250 500
L1-19/32 1-29/32 2-5/16 4-3/32 4-11/32 4-25/32 6-1/16
8-11/16
W9/16 3/4 1 1 1 1-1/4 1-7/16 1-21/32
H19/16 3/4 1-3/32 1-3/32 1-3/32 1-3/8 1-5/8 1-7/8
H2 MAX..79 .86 1.28 1.29 1.30 1.48 1.98 2.34
NO. OF SCREWS2 2 2 4 4 4 4 6
SCREW DIA.3/8 7/16 9/16 5/8 11/16 13/16 15/16 1-1/8
HEX SIZES S 5/16 5/16 5/16 3/8 1/2 9/16
* Slotted Screws. H2 measured with maximum conductors, reference
only. Complies with NFPA 78-86.
BURNDYMechanicalTYPE AGSKITABOVE GRADE SPLICE KITS For all
Aluminum or Copper/Aluminum CombinationsType AGS Above Grade Splice
Kit consists of a standard AMS splice/reducer and a heavy wall
heat-shrink sleeve. The AMS Splice is dual rated for use with
aluminum and copper conductors and are constructed from high
strength, tin plated aluminum that provides low contact resistance
and reduces the effects of galvanic corrosion. Connector is
installed with common installation tools. The heavy wall heat
shrink sleeve is lined with adhesive material, providing a positive
seal against moisture egress. Heat shrink sleeve is installed with
standard propane torch, or electric heat gun. A-31
Fig. 1
Fig. 2
Catalog Number AGSKIT2 AGSKIT250
Figure Number 1 2
Wire Range Maximum Minimum 2 8 250 1
TYPE UGSKITWATERTIGHT/UNDERGROUND SPLICE KITS For all Aluminum
or Copper/Aluminum CombinationsType UGS Watertight Underground
Splice Kit consists of a standard AMS splice/reducer and two heavy
wall heat-shrink sleeves. The AMS Splice is dual rated for use with
aluminum and copper conductors and are constructed from high
strength, tin plated aluminum that provides low contact resistance
and reduces the effects of galvanic corrosion. Connector installed
with common installation tools. Both heavy wall heat shrink sleeves
are lined with adhesive material, providing a watertight splice
that can withstand abrasions that may occur during direct burial
applications. Heat shrink sleeve installed with standard propane
torch, or electric heat gun.
Fig. 1
Fig. 2
Catalog Number UGSKIT2* UGSKIT250*
Figure Number 1 2
Wire Range Maximum Minimum 2 8 250 1
*UL486D Listed for Direct Burial
BURNDYMechanicalTYPE UGSKIT8A-32
UF DIRECT BURIAL SPLICE KITType UGS UF Splice Kit consists of a
UF splice connector and a heavy wall heat-shrink sleeve. The UF
splice connector can accommodate up to four UF conductors and is
installed with common installation tools. The heavy wall heat
shrink sleeve is lined with an adhesive material, providing a
watertight splice that can withstand abrasions that may occur
during direct burial applications. Heat shrink sleeve installed
with standard propane torch, or electric heat gun.
Catalog Number UGSKIT8**UL486D Listed for Direct Burial
Wire Range Copper 8 AWG 14 AWG
TYPE UGS350ULDBIN-LINE SPLICE/REDUCER For Direct Burial
Features and Benefits EPDM rubber covered 6061-T6 aluminum
connector. Dual rated AL9CU for copper or aluminum conductor. UL
Listed and CSA Certified for Direct Burial. Broad range taking
capability. Low installation cost.
CATALOG NUMBERUGS350ULDB
WIRE RANGE12 AWG - 350 kcmil
LENGTH In. [mm]8.50 [216]
HEIGHT In. [mm]2.81 [71.4]
HEX SIZE5/16
TORQUE (In. Lbs.)350
Dimensions in brackets [ ] are in millimeters.
BURNDYMechanicalTYPE QGFLBARTAP For Copper Cable To FlatHigh
copper alloy BARTAP for joining a range of cable to bar or pad.
One-wrench installation. A-33
CATALOG NUMBERQGFL1CB1 QGFL1CB1T6 QGFL26B1 QGFL26B1T6 QGFL26B2*
QGFL26B2T6* QGFL29B1* QGFL29B1T6* QGFL31B1* QGFL31B1T6* QGFL34B1
QGFL34B1T6 QGFL39B1 QGFL39B1T6 QGFL44B1 QGFL44B1T6 QGFL46B1
QGFL46B1T6 QGFL48B1 QGFL48B1T6
COPPER CONDUCTOR10 SOL. - 1 STR.
B1-1/8 1-1/4 1-1/2
H1-7/8 2-3/8 2-1/8 2-5/8 2-1/2 2-1/8 2-5/8 3-1/8 2-7/8 3-1/4
3-1/8 3-5/8 3-1/4 3-5/8 3-3/8 4-1/8 4 4-1/2 5-1/4 5-1/4
J3/8
T (MAX.)1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4
1/4 3/4 1/4 3/4 1/4 3/4
W1
8 SOL. - 2/0 STR.
1-1/8
6 STR. - 250 1-5/8 2 SOL. - 350 1-3/4 1/0 SOL. - 500 2 350 - 750
750 - 1000 1000 - 1500 1500 - 2000 2-1/4
1-3/8 1-5/8
1/2
1-3/4
2-1/8 2-1/2 3
* Can be installed side by side or in-line on NEMA drilled
bar.
BURNDYMechanicalTYPE FCBA-34
TRANSFORMER TAP ADAPTER For Copper and AluminumSilver brazed
101% conductivity copper transformer tap adapter designed to
accommodate from 1 to 6 NEMA drilled copper or aluminum terminal
taps from a single secondary transformer outlet. Tin-plated. Order
mounting hardware & tap terminals separately.
Fig. 1
FIG. NO.1 2 1 2 1 2 4
CATALOG NUMBERFCB63-4N FCB63-6N FCB64-4N FCB64-6N FCB65-4N
FCB65-6N FCB63-2NP300 FCB64-44NP50
A DIA..50 .50 .75 .75 1.00 1.00 .50 .75
H REF.5.25 5.25 5.75 5.75 7.00 7.00 5.00 9.00
L3.75 5.50 4.00 5.75 4.25 6.00 3.50 5.00
P2.25 2.25 2.75 2.75 4.00 4.00 3.00 5.00
NOTE: All pads are NEMA drilled.
Fig. 2
BURNDYMechanicalTYPE KPU-ACPOLYTAP Insulated Gutter Tap for All
Copper and Aluminum CombinationsWide range-taking tin-plated
aluminum parallel clamp and insulating cover assembly for
industrial and multiple story structure applications. Only six
connectors cover the entire 14 Sol.-750 kcmil range. Covers having
flexible fingers that conform to conductor, fully insulating the
connection. UL486B listed for 600 volts maximum 90 C service. Cover
and connector are packaged together. No taping required. 600 Volt
Max. 90 C A-35
CATALOG NUMBERKPU29A26AC KPU29A29AC KPU34A26AC KPU34A34AC
KPU39A26AC KPU39A39AC
CONDUCTOR COPPER OR ALUMINUM RUN TAP1/0 STR. - 250 1/0 STR. -
250 4/0 STR. - 500 4/0 STR. - 500 500 - 750 500 - 750 14 SOL. - 2/0
STR. 6 STR. - 250 14 SOL. - 2/0 STR. 6 STR. - 500 14 SOL. - 2/0
STR. 1/0 STR. - 750
W4 4-11/32 4-13/16
H2-11/16 1-7/8 3-1/4
L3-1/8 3-1/2
RECOMMENDED TIGHTENING TORQUE in-lb375 450 600
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
combinations. See note page A-2.
TYPE UCU-ACRISER TAPParallel-groove riser tap and insulation
cover for copper and aluminum. Wide range-taking assembly for
apartment house and light industrial applications. Cover and
connector are packaged together. Covers having insulating fingers
that conform to conductors, fully insulating the connection. UL486B
Listed for 600 volts max. 90 C service.
600 VOLT MAX. 90 C MAX.
CATALOG NUMBERUCU28AC
CONDUCTOR RUN TAP2 STR. - 4/0 STR. 10 SOL. - 2 STR.
W2-1/4
H1-13/16
L2-5/8
RECOMMENDED TIGHTENING TORQUE in-lb120
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
combinations.
BURNDYMechanicalTYPE BIPCINSUL-TAPA-36
UL Listed 90 C, *600 VoltThe INSUL-TAP, TYPE BIPC, Burndy
Insulation Piercing Connector is ideally suited for splicing and
tapping aluminum and copper conductor wire sizes: #10 AWG to 500
kcmil. The BIPC's unique insulation piercing design allows for use
on hot-line applications, eliminating the need for taping.
Features and Benefits Insulation piercing capability. Eliminates
the need for conductor insulation stripping. UL486B listed, AL9CU
rated. For copper and aluminum conductor combinations up to 90 *600
Volt applications. Insulation piercing design. For use on hot-line
applications. Eliminates the need for taping. Easy snap-out tabs.
Eases installation, protects connection from dirt and debris.
Simple bolt-on connection. Eases installation.
Fig. 1
Fig. 2MAX. VOLTAGE RATING600V 300V 300V 300V 300V 600V
CATALOG NUMBERBIPC1/0-2 BIPC4/0-6 BIPC4/0-1/0 BIPC350-4/0
BIPC350-350 BIPC500-4/0
CONDUCTOR RANGE RUN TAP1/0 - 8 AWG [50 - 6 mm2] 4/0 - 1/0 AWG
[95 - 50 mm2] 4/0 - 1/0 AWG [95 - 50 mm2] 350 - 4/0 AWG [185 - 95
mm2] 350 - 4/0 AWG [185 - 95 mm2] 500 - 350 kcmil [240 - 185 mm2] 2
- 8 AWG [35 - 6 mm2] 1/0 - 6 AWG [50 - 16 mm2] 4/0 - 1/0 AWG [95 -
50 mm2] 4/0 - 10 AWG [95 - 6 mm2] 350 - 4/0 AWG [185 - 95 mm2] 4/0
- 4 AWG [95 - 25 mm2]
BOLT SIZE5/16-18 5/16-18 5/16-18 3/8-16 3/8-16 3/8-16
SOCKET FIG. SIZE NO.1/2 1/2 1/2 9/16 9/16 9/16 1 2 2 1 2 1
DIMENSIONS H L W2.00 [51] 2.50 [64] 2.50 [64] 3.00 [76] 3.00
[76] 3.25 [83] 1.53 [39] 2.12 [54] 2.12 [2.12] 1.59 [40] 2.62 [67]
1.59 [40] 2.56 [65] 2.00 [51] 2.06 [52] 2.50 [64] 2.75 [70] 2.62
[67]
RECOMMENDED TORQUE (N,m)180 in. lbs. [20.3 N.m] 250 in. lbs.
[28.3 N.m] 250 in. lbs. [28.3 N.m] 375 in. lbs. [42.4 N.m] 300 in.
lbs. [33.9 N.m] 400 in. lbs. [45.2 N.m]
BURNDYMechanicalSPEC-BLOK POWER DISTRIBUTION CONNECTORSUnique,
modular, made-to-order, powerdistribution assemblies accommodate
any number of supply and load conductors in any number of poles.
Capacity matches the conductors accommodated and SPEC-BLOK assures
uniform loading. Burndy will design, quote, assemble and ship
SPEC-BLOK especially constructed to suit your particular
requirements within 48 hours upon request. Adjacent poles are
separated by easy-tohandle, wrap-around insulating covers which
eliminate taping and reduce heat build-up by allowing air to flow
freely around connectors. SPEC-BLOK is UL Listed for copper or
aluminum conductors for 600 volts. (AL9CU) Assemblies are mounted
on platforms suitable for easy installation in wireway or junction
box.
A-37
Features and Benefits Accommodate unlimited conductors. Fits
wide range of applications. Eliminates need for non-UL-listed
improvisation. Connector elements tin-plated. Provides high
reliability, low-resistance connections. User friendly,
space-saving design. Easy to install. Saves labor. 94-VO rated
insulation folds into place insulating the components. Saves time
and material. Allows easy installation. Connector caps removable
for easy cable lay-in. Saves labor. Makes installation easier.
Allows installation or straight-through conductors. Eases retrofit.
Belleville washers built-in on pressure screw assemblies, except in
assemblies installed with a 5/32" Allen wrench. Provides
high-integrity connections. Conductors can be cut or fed straight
through. Straight through installation ideal for riser
applications.
Contact Burndy or Technical Services, 1-800-451-4956 or Burndy
Customer Service, 1-800-346-4175
BURNDYMechanicalSPEC-BLOKA-38
Features and Benefits The SPEC-BLOK system includes 12 connector
elements A wide variety of conductor sizes can be accommodated Each
element can be bolted together in parallel Provides an efficient
flow of current from one element to another AL9CU rated for Copper
or Aluminum conductors Dual-rated system, with UL486Bs highest
temperature rating 2 Wire (series), 4 (parallel), and Multi-Tap
versions available Nearly any conductor combination can be
terminated Tin-plated Aluminum Alloy Construction High-strength,
corrosion-resistant connector elements All SPEC-BLOKs are custom
made for nearly any Power Distribution system requirement Time
savings pre-assembled in our factory for immediate installation! D
T
E
W
SPEC-BLOK CONNECTORS
C
S
B
R
A
Q
U
P
CATALOG DESIGNATION (MAXIMUM CONDUCTOR)
NUMBER OF CONDUCTORS ACCOMMODATED
4 Conductor A
2 Conductor Q
4 Conductor
2 Conductor
DIMENSIONS ALLEN WRENCH Second SIZE Conductor Length Without
Insulator (if Height On First Width required) Max 4 2 Conductors
May Be Conductors Conductor Conductor MUST Be 1/0-2/0 #12-2/02-9/16
1-1/2 2-1./8 7/8 5/32"
AL or CU WIRE RANGE UNDER EACH CAP
(2/0) B (250) C (350) D (500) E (750) W 600-750 3/0-7504-7/8
2-1/4 7-1/4 2-5/8
R
3/0-250
#6-2503-1/8 1-11/16 4-1/4 1-3/8 1/4" 3-5/16 1-13/16 4-5/8
1-1/2
S
1 to 4 (0, 1 or 2 per cap)
1 or 2 per cap
250-350
#6-350
T
400-500
#6-5004-1/16 2 5-5/8 1-3/4 3/8"
Catalog Designation Number of Conductors (Maximum Conductor)
Accommodated P (1/0) 1 to 8 (0, 1 or 2 under each screw) U (1/0
& 500) 2 to 9 (0, 1 or 2 under each screw plus one large
conductor)** This range may be expanded to include #8 provided two
conductors are being installed in that particular element.
Large Groove __
Small Grooves** 6-1/0
Height On Maximum Conductors 3 1/2
Width 2
Length Without Insulator
Allen Wrench Size
1 3/4 3/0-500 6-1/0 4 1/8 2
5/32"
BURNDYMechanicalSPEC-BLOKMOUNTING PLATFORMSA-39 SPEC-BLOK
Mounting Platforms are rigid steel construction with a black
finish. They can be supplied for junction box mounting or wireway
construction allowing trough conductors to pass underneath the
assemblies.
(CPB-)CATALOG NUMBERCPB6 CPB8 CPB10 CPB12 CPB16-5/8
CPB21-1/4
(CPT-)L (Nominal)6 8 10 12 16-5/8 21-1/4
L (Overall)7-3/4 9-3/4 11-3/4 13-3/4 18-3/8 23
W (Overall)2-1/2 2-1/2 2-1/2 3-1/2 3-1/2 3-1/2
CATALOG NUMBERCPT6 CPT8 CPT10 CPT12 CPT16
L5-7/8 7-7/8 9-7/8 11-7/8 15-7/8
W2-1/2 3-1/2 3-1/2 3-1/2 3-1/2
H2-1/4 3 3-1/2 4 4
SPEC-BLOK catalog numbers describe exactly how the distribution
block is assembled:5DR-NDST-GQP-12 (assembly pictured) 5 DR Total
number of poles in the completed assembly One 'D' unit and one 'R'
unit, bolted in parallel, forming each phase pole (3 phase
poles)
N
Denotes the beginning of the neutral pole (where required) DST
One 'D' unit, one 'S' unit, and on 'T' unit, bolted in parallel,
forming the neutral pole G QP Denotes the beginning of the ground
pole description (where required) One 'Q' unit and on 'P' unit,
bolted in parallel, forming the ground pole. Size (inches) of the
wireway or trough that is needed to enclose the assembly. If a
junction box enclosure is used, no number is used to denote the
size of the enclosure.
12
SPEC-BLOK IS A SYSTEM THAT CAN SOLVE MOST POWER DISTRIBUTION
APPLICATIONS!
BURNDYMechanicalQUESTIONNAIREA-40
FOR SPEC-BLOK OR ELECTRO-RAIL APPLICATIONSWhat is the total
capacity of the system?_____________amps How many poles in the
system (3-wire, 4-wire, single phase, etc.)?_____________poles Are
neutral conductors (when required) different sizes (AWG/KCMil) than
the phase conductors? _________the same size __________different
size Yes No Are any conductors continuous? Yes No
If yes, which ones?____________________________________
___________________________________________________ What kind of
enclosure is connection assembly being mounted into and what are
inside space dimensions? Trough size
_________________________________________ Box, panel, cabinet,
other size___________________________ When is a quotation required?
Date:______________________ When is the material required?
Date:_____________________ CONDUCTOR TYPE (Cu/Al) Is there a
preference for a particular Burndy distributor? Yes No If yes, give
name, location & telephone Number:
Name:______________________________________________
Is a ground connection required?
What are the quantities, sizes (AWG/kcmil) and material (Al/Cu)
of the incoming line conductors and outgoing load conductors?
QUANTITY LINE PER PHASE LOAD
SIZE
Address:____________________________________________ LINE PER
NEUTRAL LOAD LINE PER GROUND LOAD
__________________________________________________ Phone
#:____________________________________________
BURNDYMechanical3 WIRE BUS ASSEMBLY FOR TROUGH(INSULATING COVERS
AND MOUNTING BASE INCLUDED)Bus Assemblies consist of tin plated
aluminum bus mounted to an insulating platform. Each phase is
separated with 94VO 600 volt wrap-around adhesive insulations. The
entire assembly is mounted on a trough type base.
A-41
CATALOG NUMBER1300A-8-3-10 1300A-12-3-10 1300A18-3-10
1300A-24-3-10 1300A-30-3-10 1350A-8-3-12 1350A-12-3-12
1350A-18-3-12 1350A-24-3-12 1350A-30-3-12 1500A-12-3-10
1500A-18-3-10 1500A-24-3-10 1500A-30-3-10 1500A-12-3-12
1500A-18-3-12 1500A-24-3-12 1500A-30-3-12
AMP RATING PER BUS1300 1300 1300 1300 1300 1350 1350 1350 1350
1350 1500 1500 1500 1500 1500 1500 1500 1500
DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 8 12 18 24 30 12
18 24 30 12 18 24 30 12 16 22 28 34 12 16 22 28 34 16 22 28 34 16
22 28 34
WIDTH10 10 10 10 10 12 12 12 12 12 10 10 10 10 12 12 12 12
HEIGHT4.75 4.75 4.75 4.75 4.75 5.25 5.25 5.25 5.25 5.25 4.75
4.75 4.75 4.75 5.25 5.25 5.25 5.25
WEIGHT8 lbs. 11 lbs. 15 lbs. 22 lbs. 26 lbs. 9 lbs. 12 lbs. 16
lbs. 23 lbs. 27 lbs. 15 lbs. 18 lbs. 27 lbs. 30 lbs. 16 lbs. 19
lbs. 28 lbs. 31 lbs.
PCS. PER CTN.1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
BURNDYMechanical4 WIRE BUS ASSEMBLY FOR TROUGH(INSULATING COVERS
AND MOUNTING BASE INCLUDED)
A-42
CATALOG NUMBER1350A-8-4-12 1350A-12-4-10 1350A-18-4-12
1350A-24-4-12 1350A-30-4-12 1500A-12-4-12 1500A-18-4-12
1500A-24-4-12 1500A-30-4-12
AMP RATING PER BUS1350 1350 1350 1350 1350 1500 1500 1500
1500
DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 12 18 24 30 12 16
22 28 34 16 22 28 34
WIDTH12 12 12 12 12 12 12 12 12
HEIGHT5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25
WEIGHT10 lbs. 13 lbs. 17 lbs. 26 lbs. 30 lbs. 18 lbs. 21 lbs. 30
lbs. 34 lbs.
PCS. PER CTN.1 1 1 1 1 1 1 1 1
BURNDYMechanicalWIRE BUS ASSEMBLY FOR JUNCTION BOXES(INSULATING
COVERS AND MOUNTING BASE INCLUDED)
A-43
3 WIRE BUS ASSEMBLY FOR JUNCTION BOXES (INSULATING COVERS AND
MOUNTING BASE INCLUDED)CATALOG NUMBER1350A-8-3-B 1350A-12-3-B
1350A-18-3-B 1350A-24-3-B 1350A-30-3-B 1500A-12-3-B 1500A-18-3-B
1500A-24-3-B 1500A-30-3-B
AMP RATING PER BUS1350 1350 1350 1350 1350 1500 1500 1500
1500
DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 12 18 24 30 12 16
22 28 34 16 22 28 34
WIDTH12 12 12 12 12 12 12 12 12
HEIGHT2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75
WEIGHT9 lbs. 12 lbs. 16 lbs. 23 lbs. 27 lbs. 15 lbs. 18 lbs. 27
lbs. 30 lbs.
PCS. PER CTN.1 1 1 1 1 1 1 1 1
4 WIRE BUS ASSEMBLY FOR JUNCTION BOXES (INSULATING COVERS AND
MOUNTING BASE INCLUDED)CATALOG NUMBER1350A-8-4-B 1350A-12-4-B
1350A-18-4-B 1350A-24-4-B 1350A-30-4-B 1500A-12-4-B 1500A-18-4-B
1500A-24-4-B 1500A-30-4-B
AMP RATING PER BUS1350 1350 1350 1350 1350 1500 1500 1500
1500
DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 12 18 24 30 12 16
22 28 34 16 22 28 34
WIDTH16 16 16 16 16 16 16 16 16
HEIGHT2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75
WEIGHT10 lbs. 13 lbs. 17 lbs. 26 lbs. 30 lbs. 18 lbs. 21 lbs. 30
lbs. 34 lbs.
PCS. PER CTN.1 1 1 1 1 1 1 1 1
BURNDYMechanicalVERSI-POLEA-44
POWER DISTRIBUTION BLOCKSVERSI-POLE Power Distribution Blocks
are designed to provide modular solutions to power distribution
applications. Each connector element is made from a high
conductivity aluminum alloy which is insulated with a high strength
polymer housing. One, two, and three pole versions available. "Add"
a pole (snap-together) blocks are also available for wire sizes up
to 500 kcmil. For use with Cu or Al. 600 V, AL9CU rated.
Features and Benefits "Add" a pole feature available. Provides
capability to create as many poles as required. Up to 30 tap
conductors accommodated. Ideal for current distribution to multiple
locations. Single or dual run connections. Allows user to minimize
the number of connectors needed to do the job. Suitable for use
with aluminum or copper conductors. Provides maximum versatility.
600 V, AL9CU rated.* Meets or exceeds industry standard
requirements. Dead-front covers available Provides user protection
one cover per pole.* BDB-430-500-1 not UL recognized or CSA
certified
VERSI-POLE SNAPTOGETHER BLOCKSCATALOG NUMBERBDA-112-350
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CU350 kcmil - 6
TAP WIRE RANGE AL9CU4 - 14
AMPERE RATING PER POLE350
NUMBER OF POLESADDER
BDA-16-350
350 kcmil - 6
2/0 - 14
350
ADDER
BDA-16-500
500 kcmil - 4
2/0 - 4
430
ADDER
BDA-26-350
350 kcmil - 6
2/0 - 14
700
ADDER
BDA-212-500
500 kcmil - 4
4 - 14
860
ADDER
BDA-26-500
500 kcmil - 4
2/0 - 14
860
ADDER
BDA-24-500
500 kcmil - 4
4/0 - 6
860
ADDER
BDA-11-500
500 kcmil - 4
500 kcmil - 4
430
ADDER
BDA-22-350
350 kcmil - 6
350 kcmil - 6
700
ADDER
BDA-22-500NOTES: 1. Order Optional BDB COVER1 per pole if
desired. 2. Snap-together blocks can also be assembled to 1, 2, 3
pole blocks to create multi-pole distribution blocks.
500 kcmil - 4
500 kcmil - 4
860
ADDER
BURNDYMechanicalVERSI-POLEVERSI-POLE 1, 2, 3 POLE DISTRIBUTION
BLOCKSA-45
CATALOG NUMBERBDB-16-2/0-1 BDB-16-2/0-2 BDB-16-2/0-3
BDB-26-2/0-1 BDB-26-2/0-2 BDB-26-2/0-3 BDB-112-350-1 BDB-112-350-2
BDB-112-350-3 BDB-16-350-1 BDB-16-350-2 BDB-16-350-3 BDB-14-500-1
BDB-14-500-2 BDB-14-500-3 BDB-16-500-1 BDB-16-500-2 BDB-16-500-3
BDB-162-500-1 BDB-162-500-2 BDB-162-500-3 BDB-26-350-1 BDB-26-350-2
BDB-26-350-3 BDB-212-500-1 BDB-212-500-2 BDB-212-500-3 BDB-26-500-1
BDB-26-500-2 BDB-26-500-3 BDB-24-500-1 BDB-24-500-2
BDB-24-500-3
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CU2/0 - 12
TAP WIRE RANGE AL9CU4 - 14
AMPERE RATING PER POLE195
OPTIONAL NUMBER OF COVER ORDER POLES 1 PER POLE1 2 3 1 2 3 1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 BDBCOVER2
2/0 - 14
2 - 14
390
BDBCOVER2
350 kcmil - 6
4 - 14
350
BDBCOVER1
350 kcmil - 6
2/0 - 14
350
BDBCOVER1
500 kcmil - 4
2/0 - 14
430
BDBCOVER2
500 kcmil - 4
2/0 - 14
430
BDBCOVER1
500 kcmil - 4
2 - 14
430
BDBCOVER2
350 kcmil - 6
2/0 - 14
700
BDBCOVER1
500 kcmil - 4
4 - 14
860
BDBCOVER1
500 kcmil - 4
2/0 - 14
860
BDBCOVER1
500 kcmil - 4
4/0 - 6
860
BDBCOVER1
BURNDYMechanicalVERSI-POLEA-46
VERSI-POLE 1, 2, 3 SPLICE/REDUCER BLOCKSCATALOG
NUMBERBDB-11-2/0-1 BDB-11-2/0-2 BDB-11-2/0-3 BDB-11-350-1
BDB-11-350-2 BDB-11-350-3 BDB-11-500-1 BDB-11-500-2 BDB-11-500-3
BDB-22-2/0-1 BDB-22-2/0-2 BDB-22-2/0-3 BDB-22-350-1 BDB-22-350-2
BDB-22-350-3 BDB-22-500-1 BDB-22-500-2 BDB-22-500-3
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CU2/0 - 14
TAP WIRE RANGE AL9CU2/0 - 14
AMPERE RATING PER POLE195
OPTIONAL NUMBER OF COVER ORDER POLES 1 PER POLE1 2 3 1 2 3 1 2 3
1 2 3 1 2 3 1 2 3 BDBCOVER2
350 kcmil - 6
350 kcmil - 6
350
BDBCOVER2
500 kcmil - 6
500 kcmil - 6
430
BDBCOVER1
2/0 - 14
2/0 - 14
390
BDBCOVER2
350 kcmil - 6
350 kcmil - 6
700
BDBCOVER1
500 kcmil - 4
500 kcmil - 4
860
BDBCOVER1
SNAP TOGETHER SPLICER/REDUCER BLOCKSCATALOG
NUMBERBDC-14-2/0-1
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CU2/0 - 14
TAP WIRE RANGE AL9CU4 - 14
AMPERE RATING PER POLE195
OPTIONAL NUMBER OF COVER ORDER POLES 1 PER POLE1 BDBCOVER3
BDA-14-2/0-1
2/0 - 14
4 - 14
195
ADDER
BDBCOVER3
BDC-11-2/0-1
2/0 - 14
2/0 - 14
195
1
BDBCOVER3
BDA-11-2/0-1
2/0 - 14
2/0 - 14
195
ADDER
BDBCOVER3
BURNDYMechanicalVERSI-POLE(Continued) VERSI-POLE 1, 2, 3
SPLICE/REDUCER BLOCKSThese tables and illustrations refer to
VERSIPOLE Power Distribution Blocks listed on pages A-48 through
A-50. A-47
THE FIGURE TO THE LOWER RIGHT IS APPLICABLE TO THE
FOLLOWING:Catalog Number BDA-11-500 BDA-112-350 BDA-16-350
BDA-16-500 BDA-212-500 BDA-22-350 BDA-22-500 BDA-24-500 BDA-26-350
BDA-26-500 BDB-11-500-1 BDB-11-500-2 BDB-11-500-3 BDB-112-350-1
BDB-112-350-2 BDB-112-350-3 BDB-16-350-1 BDB-16-350-2 BDB-16-350-3
BDB-16-500-1 BDB-16-500-2 Number of Poles 1 (adder) 1 (adder) 1
(adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder)
1 (adder) 1 2 3 1 2 3 1 2 3 1 2 Catalog Number BDB-16-500-3
BDB-212-500-1 BDB-212-500-2 BDB-212-500-3 BDB-22-350-1 BDB-22-350-2
BDB-22-350-3 BDB-22-500-1 BDB-22-500-2 BDB-22-500-3 BDB-24-500-1
BDB-24-500-2 BDB-24-500-3 BDB-26-350-1 BDB-26-350-2 BDB-26-350-3
BDB-26-500-1 BDB-26-500-2 BDB-26-500-3 BDB-430-500-1 Number of
Poles 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1
NO. OF POLESAdder 1 2 3 N
DIMENSIONS A INCHES2.50 2.81 5.31 7.81 (2.50 X N) + .31
Example for 10 poles: A = (2.50 X 10) + .31 = 25
BURNDYMechanicalVERSI-POLE(Continued)A-48
VERSI-POLE 1, 2, 3 SPLICE/REDUCER BLOCKSThese tables and
illustrations refer to VERSIPOLE Power Distribution Blocks listed
on pages A-48 through A-50. THE FIGURE TO THE RIGHT IS APPLICABLE
TO THE FOLLOWING:Catalog Number BDB-11-2/0-1 BDB-11-2/0-2
BDB-11-2/0-3 BDB-11-350-1 BDB-11-350-2 BDB-11-350-3 BDB-14-500-1
BDB-14-500-2 BDB-14-500-3 BDB-16-2/0-1 BDB-16-2/0-2 BDB-16-2/0-3
BDB-162-500-1 BDB-162-500-2 BDB-162-500-3 BDB-22-2/0-1 BDB-22-2/0-2
BDB-22-2/0-3 BDB-26-2/0-1 BDB-26-2/0-2 BDB-26-2/0-3 Number of Poles
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
NO. OF POLESAdder 1 2 3 N
DIMENSIONS A INCHES1.64 1.94 3.57 5.20 (1.64 X N) + .30
Example for 10 poles: A = (1.64 X 10) + .30 = 16.20
APPLICABLE VERSI-POLETM ITEMS Catalog Number BDA-14-2/0-1
BDC-14-2/0-1 BDA-11-2/0-1 BDC-11-2/0-1 Number of Poles 1 (adder) 1
1 (adder) 1
NO. OF POLESAdder 1 2 3 N
DIMENSIONS A INCHES.81 1.08 1.89 2.70 (.81 X N) + .27
Example for 10 poles: A = (.81 X 10) + .27 = 8.37
BURNDYMechanicalBURNDY UNITAPCLEAR INSULATED MULTIPLE TAP
CONNECTORSTap connections and in-line splice/reductions are made
quickly and easily with the UNITAP line of connectors. UL486B
Listed. Dual-rated AL9CU for any stranded copper or stranded
aluminum applications. 600 Volt, 90 C. A-49
Features and Benefits Clear Plastisol covered AL6061-T6 aluminum
body. Saves time, lowers installation costs, eliminates taping.
Clear Plastisol. Allows visual confirmation that conductor is
properly inserted. Oxide inhibitor pre-installed. Inhibits moisture
and contaminants from entering the contact area. Range-taking.
Reduces number of connectors carried in inventory.
2 PORT 1 or 2 Sided EntryCatalog NumberBIT4 BITO4 BIT2/0 BITO2/0
BIT250 BITO250 BIT350 BITO350 BIT600 BITO600 BIT750* BITO750** Not
UL Listed
# of Ports2 2 2 2 2 2 2 2 2 2 2 2
Wire Range (AWG/kcmil)#14 - #4 #14 - #4 #14 - 2/0 #14 - 2/0 #10
- 250 #10 - 250 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #2 - 750 #2 -
750
L1.16 1.16 1.52 1.52 2.03 2.03 2.22 2.22 2.72 2.72 2.87 2.87
W1.16 1.50 1.40 1.56 2.07 2.64 2.32 3.00 2.38 3.00 2.70 3.38
H1.25 1.25 1.38 1.38 2.13 2.13 2.50 2.50 2.75 2.75 3.00 3.00
Hex Key1/8 1/8 3/16 3/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8
Fig. No.1 2 1 2 1 2 1 2 1 2 1 2
Fig. 1
Fig. 2
IN-LINE SPLICER/REDUCERCatalog NumberBISR2 BISR1/0 BISR250
BISR350 BISR500
Wire Range (AWG/kcmil)#14 - 2 #14 - 1/0 #10 - 250 #10 - 350 #6 -
500
L2.38 2.91 4.01 4.63 5.00
W0.75 0.91 1.19 1.34 1.62
H1.22 1.38 2.10 2.35 2.62
Hex Key5/32 3/16 5/16 5/16 3/8
BURNDYMechanicalBURNDY UNITAPA-50
MULTI-PORT Single-Sided EntryCatalog NumberBIBS4-3 BIBS4-4
BIBS4-5 BIBS4-6 BIBS4-8 BIBS2/0-3 BIBS2/0-4 BIBS2/0-5 BIBS2/0-6
BIBS2/0-8 BIBS2/0-10 BIBS2/0-12 BIBS2/0-14 BIBS250-3 BIBS250-4
BIBS250-5 BIBS250-6 BIBS250-8 BIBS250-10 BIBS250-12 BIBS250-14
BIBS350-3
# of Wire Range Ports (AWG/kcmil)3 4 5 6 8 3 4 5 6 8 10 12 14 3
4 5 6 8 10 12 14 3 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #14 -
2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14
- 2/0 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250
#10 - 250 #10 - 250 #10 - 350
L1.59 2.03 2.47 2.91 3.78 2.19 2.86 3.53 4.20 5.55 6.89 8.24
9.58 2.97 3.91 4.84 5.78 7.66 9.53 11.41 13.29 3.13
W1.25 1.25 1.25 1.25 1.25 1.31 1.31 1.31 1.31 1.31 1.31 1.31
1.31 2.07 2.07 2.07 2..07 2.07 2.07 2.07 2.07 2.32
H1.25 1.25 1.25 1.25 1.25 1.38 1.38 1.38 1.38 1.38 1.38 1.38
1.38 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.50
Hex Key1/8 1/8 1/8 1/8 1/8 3/16 3/16 3/16 3/16 3/16 3/16 3/16
3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16
Catalog NumberBIBS350-4 BIBS350-5 BIBS350-6 BIBS350-8 BIBS350-10
BIBS350-12 BIBS350-14 BIBS600-3 BIBS600-4 BIBS600-5 BIBS600-6
BIBS600-8 BIBS600-10 BIBS600-12 BIBS600-14 BIBS750-3* BIBS750-4*
BIBS750-6* BIBS750-8* BIBS750-10* BIBS750-12* BIBS750-14** Not UL
Listed
# of Wire Range Ports (AWG/kcmil)4 5 6 8 10 12 14 3 4 5 6 8 10
12 14 3 4 6 8 10 12 14 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10
- 350 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 -
600 #4 - 600 #4 - 600 #4 - 600 #2 - 750 #2 - 750 #2 - 750 #2 - 750
#2 - 750 #2 - 750 #2 - 750
L4.04 4.95 5.86 7.68 9.50 11.32 13.14 4.00 5.28 6.56 7.84 10.41
12.97 15.53 18.09 4.25 5.63 8.37 11.13 13.87 16.63 19.37
W2.32 2.32 2.32 2.32 2.32 2.32 2.32 2.38 2.38 2.38 2.38 2.38
2.38 2.38 2.38 2.70 2.70 2.70 2.70 2.70 2.70 2.70
H2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75 2.75
2.75 2.75 2.75 3.00 3.00 3.00 3.00 3.00 3.00 3.00
Hex Key5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8 3/8
3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
BURNDYMechanicalBURNDY UNITAPA-51
MULTI-PORT Double-Sided EntryCatalog NumberBIBD4-2 BIBD4-3
BIBD4-4 BIBD4-5 BIBD4-6 BIBD4-8 BIBD2/0-2 BIBD2/0-3 BIBD2/0-4
BIBD2/0-5 BIBD2/0-6 BIBD2/0-8 BIBD2/0-10 BIBD2/0-12 BIBD2/0-14
BIBD250-2 BIBD250-3 BIBD250-4 BIBD250-5 BIBD250-6 BIBD250-8
BIBD250-10 BIBD250-12 BIBD250-14 BIBD350-2
# of Wire Range Ports (AWG/kcmil)2 3 4 5 6 8 2 3 4 5 6 8 10 12
14 2 3 4 5 6 8 10 12 14 2 #14 - #4 #14 - #4 #14 - #4 #14 - #4 #14 -
#4 #14 - #4 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 -
2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #10 - 250 #10 - 250 #10 - 250 #10
- 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 -
350
L1.16 1.59 2.03 2.47 2.91 3.78 1.52 2.19 2.86 3.53 4.20 5.55
6.89 8.24 9.58 2.03 2.97 3.91 4.84 5.78 7.66 9.53 11.41 13.29
2.22
W1.50 1.50 1.50 1.50 1.50 1.50 1.56 1.56 1.56 1.56 1.56 1.56
1.56 1.56 1.56 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64
3.00
H1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
1.25 1.25 1.25 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13
2.50
Hex Key1/8 1/8 1/8 1/8 1/8 1/8 3/16 3/16 3/16 3/16 3/16 3/16
3/16 3/16 3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16
5/16
Catalog NumberBIBD350-3 BIBD350-4 BIBD350-5 BIBD350-6 BIBD350-8
BIBD350-10 BIBD350-12 BIBD350-14 BIBD600-2 BIBD600-3 BIBD600-4
BIBD600-5 BIBD600-6 BIBD600-8 BIBD600-10 BIBD600-12 BIBD600-14
BIBD750-2* BIBD750-3* BIBD750-4* BIBD750-6* BIBD750-8* BIBD750-10*
BIBD750-12* BIBD750-14*
# of Wire Range Ports (AWG/kcmil)3 4 5 6 8 10 12 14 2 3 4 5 6 8
10 12 14 2 3 4 6 8 10 12 14 #10 - 350 #10 - 350 #10 - 350 #10 - 350
#10 - 350 #10 - 350 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #4 - 600
#4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #2 - 750 #2 -
750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750
L3.13 4.04 4.95 5.86 7.68 9.50 11.32 13.14 2.56 3.77 4.97 6.17
7.37 9.78 12.97 15.53 18.09 2.87 4.25 5.63 8.37 11.13 13.87 16.63
19.37
W3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00
3.00 3.00 3.00 3.00 3.00 3.38 3.38 3.38 3.38 3.38 3.38 3.38
3.38
H2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75
2.75 2.75 2.75 2.75 2.75 3.00 3.00 3.00 3.00 3.00 3.00 3.00
3.00
Hex Key5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8
3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
NOTE: Only 1 conductor per port allowed. * Not UL Listed
BURNDYMechanicalBURNDY UNITAPA-52
CLEAR INSULATED MULTIPLE TAP CONNECTORS MOUNTING VERSION TYPE
BIBS-MT, BIBD-MTThe BIBS-MT and BIBD-MT series UNITAP offer the
same multi-port capabilities as the standard UNITAP connectors
except these -MT types are provided with two isolated mounting
holes at both ends of the connector for direct mounting to a
trough, gutter or wireway. They will accommodate up to standard 1/4
hardware.
Fig. 1
Fig. 2
MULTI-PORT Single-Sided EntryCatalog Number BIBS2/04MT
BIBS2/06MT BIBS2/08MT BIBS2/010MT BIBS2/012MT BIBS2504MT BIBS2506MT
BIBS2508MT BIBS25010MT BIBS25012MT BIBS3504MT BIBS3506MT BIBS3508MT
BIBS35010MT BIBS35012MT BIBS6004MT BIBS6006MT BIBS6008MT
BIBS60010MT BIBS60012MT # of Fig # Ports 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 Wire
Range (AWG/Kcmil) #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #10-250
#10-250 #10-250 #10-250 #10-250 #10-350 #10-350 #10-350 #10-350
#10-350 #4-600 #4-600 #4-600 #4-600 #4-600 L 3.95 5.29 6.64 7.98
9.33 5.53 7.40 9.28 11.16 13.03 5.61 7.43 9.25 11.07 12.89 7.59
10.16 12.72 15.28 17.84 W 1.31 1.31 1.31 1.31 1.31 2.07 2.07 2.07
2.07 2.07 2.32 2.32 2.32 2.32 2.32 2.38 2.38 2.38 2.38 2.38 H 1.38
1.38 1.38 1.38 1.38 2.13 2.13 2.13 2.13 2.13 2.50 2.50 2.50 2.50
2.50 2.75 2.75 2.75 2.75 2.75 Hex Key 3/16 3/16 3/16 3/16 3/16 5/16
5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8
3/8
MULTI-PORT Double-Sided EntryCatalog Number BIBD2/04MT
BIBD2/06MT BIBD2/08MT BIBD2/010MT BIBD2/012MT BIBD2504MT BIBD2506MT
BIBD2508MT BIBD25010MT BIBD25012MT BIBD3504MT BIBD3506MT BIBD3508MT
BIBD35010MT BIBD35012MT BIBD6004MT BIBD6006MT BIBD6008MT
BIBD60010MT BIBD60012MT # of Fig # Ports 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 Wire
Range (AWG/Kcmil) #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #10-250
#10-250 #10-250 #10-250 #10-250 #10-350 #10-350 #10-350 #10-350
#10-350 #4-600 #4-600 #4-600 #4-600 #4-600 L 3.95 5.29 6.64 7.98
9.33 5.53 7.40 9.28 11.16 13.03 5.61 7.43 9.25 11.07 12.89 7.59
10.16 12.72 15.28 17.84 W 1.56 1.56 1.56 1.56 1.56 2.64 2.64 2.64
2.64 2.64 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 H 1.38
1.38 1.38 1.38 1.38 2.13 2.13 2.13 2.13 2.13 2.50 2.50 2.50 2.50
2.50 2.75 2.75 2.75 2.75 2.75 Hex Key 3/16 3/16 3/16 3/16 3/16 5/16
5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8
3/8
BURNDYMechanicalBURNDY UNITAP THE MOLEFor Direct Burial 600V,
90CDesigned specifically for direct burial applications, the MOLE
inline splice/reducer is made with a specialized plastisol material
that forms a rugged weathertight connection. A-53
Features and Benefits UL486D Listed for direct burial. AL9CU
Dual-rated for copper and aluminum applications. 600V 90C.
Plastisol covered AL6061-T6 aluminum body saves time by eliminating
the need for heat shrink. Oxide inhibitor pre-installed preventing
moisture and contaminants from entering contact area. Range-taking
capability reduces the number of connectors carried in
inventory.
Catalog NumberBISR4-DB BISR1-DB BISR3/0-DB BISR250-DB
Number of Ports2 2 2 2
Wire Range (AWG/kcmil)#6 - 4 AWG #2 - 1 AWG 1/0 - 3/0 AWG 4/0 -
250 kcmil
Dimensions (Inches) L W H4.30 6.30 6.25 6.70 0.80 0.93 0.99 1.18
1.28 1.59 1.84 2.03
Hex Key (Torque) (In.-lbs.)1/8 (50) 5/32 (130) 3/16 (220) 5/16
(360)
Wire Strip Length7/8 1-3/32 1-3/32 1-5/16
BISR-DB = BURNDY Inline Splice/Reducer Direct Burial
BURNDYMechanicalUV RATED BLACK UNITAPA-54
For Direct Burial 600V, 90C
Features and Benefits UV Rated Plastisol covered AL6061-T6
aluminum body saves time by eliminating the need for taping. Oxide
inhibitor pre-installed inhibits moisture and contaminants from
entering the contact area. Range-taking capability reduces the
number of connectors carried in inventory. UL486B Listed, AL9CU,
600V 90C
Catalog Number1PL42 1PLO42 1PL2/02 1PLO2/02 1PL2502 1PLO2502
1PL3502 1PL6002 1