Top Banner
At FCI, we believe that customer satisfaction comes first, so we offer you... A Complete Line. We have the broadest selection of the highest quality connectors, installation tools and accessories of anyone in the industry. A Dedicated Sales Force. FCI BURNDY Products employs 135 sales and market specialists to solve your most complicated connector problems. On Time Delivery. FCI ships 99% of all stock orders within 24 hours. Technical Assistance. Field experienced tech specialists are only a phone call away. For More Information Call 1-800-346-4175 “Thank you for your interest in FCI BURNDY ® Products. All of our 1300 plus employees in North America are committed to YOU, our VALUED CUSTOMER. For over 80 years, the BURNDY ® brand of connectors and installation tooling has been synonymous with excellence, service and value.We are excited to bring you some new BURNDY ® products such as the BURNDYWeld™ line of EXOTHERMIC GROUNDING which is shown in our Grounding section and our new line of 4PT TOOLS which can be found in the Tooling sec- tion. Our black UNITAP™ multiple tap connectors are shown at the end of the Mechanical Section and the CLEAR H-TAP COVERS are in the Compression section. I appreciate your continued support and look forward to exceeding your expectations.” Tom Robinson Vice President of Sales
724

FCI BURNDY

Oct 30, 2014

Download

Documents

carameloo2012
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript

At FCI, we believe that customer satisfaction comes first, so we offer you...

A Complete Line.We have the broadest selection of the highest quality connectors, installation tools and accessories of anyone in the industry.

A Dedicated Sales Force.FCI BURNDY Products employs 135 sales and market specialists to solve your most complicated connector problems.

On Time Delivery.FCI ships 99% of all stock orders within 24 hours.

Technical Assistance.Field experienced tech specialists are only a phone call away.

For More Information Call

1-800-346-4175

Thank you for your interest in FCI BURNDY Products. All of our 1300 plus employees in North America are committed to YOU, our VALUED CUSTOMER. For over 80 years, the BURNDY brand of connectors and installation tooling has been synonymous with excellence, service and value. We are excited to bring you some new BURNDY products such as the BURNDYWeld line of EXOTHERMIC GROUNDING which is shown in our Grounding section and our new line of 4PT TOOLS which can be found in the Tooling section. Our black UNITAP multiple tap connectors are shown at the end of the Mechanical Section and the CLEAR H-TAP COVERS are in the Compression section. I appreciate your continued support and look forward to exceeding your expectations. Tom Robinson Vice President of Sales

MASTER INDEXA MECHANICAL bolts or allen head devices....... ....... Connectors secured by nuts, ............ B SMALL COMPRESSION crimps ............. ................... Connectors secured by indent or circumferential C MEDIUM AND LARGE COMPRESSION ...... .......... Connectors secured by indent or circumferential crimps ........ D GROUNDING Grounding System and Mechanical Grounding .... Irreversable Compression ......... .... E OVERHEAD both Mechanical and Compression used on pole applications .................. Power distribution connectors F WEJTAP systems .......... Power actuated connection ... ............. G SUBSTATION for tube cable and bus applications ... Power distribution connectors ... ... H ALUMINUM WELDMENTS Extra High Voltage devices ............................................... .............. I NETWORK UNDERGROUND ... ........................... Power distribution connectors for underground applications J URD UNDERGROUND applications ........ Power distribution connectors for underground ...................... K CABLE TIES UNIRAP cable ties ......................... ........................... L HARDWARE of various metals ............ .................. Nuts, Bolts and Washers ........... M ACCESSORIES Terminal Blocks ................................................. Oxide Inhibitors Markers and N TOOLING Hydraulic and Pneumatic ........ ... Hand-Held, Mechanical ............ O REFERENCES General Information ................................................ Dies, Connectors Charts and

MASTER INDEX........................... A ................ ......................... ............... B ..................................................................................... C ............. .................... D ................... ....... .... ....... E .......... ................. .... ..................................................................................... F ..................................................................................... G ..................................................................................... H ....... ................................................................... I ..................................................................................... J ..................................................................................... K ................................ ............................................... L ............................................. M ............................... ......... ...................... ......................... N ..................................................................................... O ...............................................

BURNDYMechanicalTABLE OF CONTENTSTypes KS, KS-3 & SC. . . A-4 Type KSU . . . . . . . . . . . . A-5 Type KSA . . . . . . . . . . . . A-6 Types KVS, KVSU . . . . . A-7 Types KVSW, KVS-A . . . A-8 Type QPX . . . . . . . . . . . . A-9 Type QPX-Y . . . . . . . . . A-10 Type KPA . . . . . . . . . . . A-11 Type KPA-UP . . . . . . . . A-12 Type KLU . . . . . . . . . . . A-13 Types KA, EA . . . . . . . . A-14 Types BGBL, CL50-1 . . A-15 Types QA, QQA . . . . . . A-16 Types Q2A, Q3A. . . . . . A-17 Types QB, Q2B . . . . . . A-18 Types QDA & QR . . . . . A-19 Types VT, E-C-G . . . . . . A-20 Types K4A-U, KK4A, K11A-U, K21A, K22A . A-28 Type KAU-KIT . . . . . . . A-29 Type AMS. . . . . . . . . . . A-30 Type AGSKIT . . . . . . . . A-31 Type UGSKIT . . . . . . . . A-31 Type BISR-DB . . . . . . . A-53 Type UGSKIT8 . . . . . . . A-32 Type 1PL . . . . . . . . . . . A-54 Type UGS350ULDB . . . A-32 Type QGFL. . . . . . . . . . A-33 Type FCB . . . . . . . . . . . A-34 Types KPU-AC, UCU-AC . . . . . . . . . . . A-35Complies with NFPA 78-86 Ordinary Structures. Complies with NFPA 78-86 Heavy Duty Stacks (order: LD for Lead Plating for Heavy Duty Stacks applications).

Types VA, VVA . . . . . . . A-21 Type HFB-P1 . . . . . . . . A-22 Type HFB-N . . . . . . . . . A-23 Types KA-U, KKA-U . . . A-24 Type K2A-U . . . . . . . . . A-25 Types K3A-U, KK3A-U . . . . . . . . . . . . . . A-26, A-27

Type BIPC . . . . . . . . . . A-36 SPEC-BLOK . . . . A-37, A-38 SPEC-BLOK PLATFORMS . . . . . . . A-39 Types 1300A, 1350A, 1500A . . . A-41, A-42, A-43 Types BDA, BDB, BDC . . . . . . . . . A-44, A-45, A-46, A-47, A-48 Types BIT, BISR . . . . . . A-49 Type BIBS . . . . . . . . . . A-50 Type BIBD . . . . . . . . . . A-51 Types BIBS-MT, BIBD-MT . . . . . . . . . . A-52

A-1

BURNDYMechanicalLIGHTNING PROTECTION INFO.Basic rules for selection are: 1 Must be like material to the conductor (Flexitap out due to steel bolts!). A-2 2. Two bolts to ground rod minimum. 3 Cable to cable connections can be anything one bolt, two bolt, compression, etc. 4 Cable to steel structure must have 8 square inch contact with steel. 5. Heavy duty stacks mechanical only. 6. On all connectors with heavy duty stack rating, we must offer 1/16" thick lead plating as an option. Reason is closest 25 ft. to stack opening must use lead coated product. Complies with NFPA 78-86 Ordinary Structures. Complies with NFPA 78-86 Heavy Duty Stacks (order: LD for Lead Plating for Heavy Duty Stack applications)

SPECIAL FEATURESOther features are also available for products listed in price book such as undrilled or special drilling, 45 or 90 pad angles, belling for extra flexible cable, smooth or special threaded studs, special labeling or packaging, extra long braid, and nuclear certification. REFER TO FACTORY.

ALL OTHERS REFER TO FACTORY 1-800-346-4175

BURNDYMechanicalREVOLUTIONARY BURNDY DESIGN MEETS STRICT UL 486B STANDARDS. . . and puts the bite on aluminum connections forever!For use on all combinations Aluminum to aluminum Aluminum to copper Copper to copper PatentedAvailable in sizes from #10 through 500 kcmil.

A-3

Unique bite and grip TRITAP SERVIT contact delivers safe, long-term reliabilityeven without scratch brushing . . . without oxide inhibiting compounds.

Spacer provides built-in separation to retard galvanic corrosion.

Triangular edges bite into cable to break through surface oxides ...provide low contact resistance. ...produces gas tight seal.

Tin-plated contact surface inhibits oxide formation.

Special heat-treated hard, aluminum alloy.

Anti-galling, high efficiency threaded components result in high contact force. Easily installed using standard, everyday wrenches.

When used in NEC applications of insulated cables only.

BURNDYMechanicalTYPES KS & KS-3SERVITA-4

For Copper, CopperweldCompact, high strength, high copper alloy SERVIT split-bolt has free-running threads and easy to grip wrench flats. Highly resistant to season cracking and corrosion, the SERVIT provides maximum pressure and assures a secure connection on all combinations of run and tap conductors. Type KS-3 accommodates 3 maximum size conductors.

CONDUCTOR COPPER CATALOG NUMBERKS90 **KS15 **KS17 * KS17-3 **KS20 * KS20-3 **KS22 * KS22-3 **KS23 **KS25 **KS26 **KS27 **KS29 **KS31 **KS34 KS39 KS44

COPPERWELD MIN. TAP WITH MAX. RUN16 STR. 14 STR. 14 STR. 16 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 14 STR. 8 SOL. 8 STR. 1/0 STR. 2/0 STR. 4/0 STR. 4/0 STR.

RECOMMENDED TIGHTENING TORQUE in-lb80

CROSS FLATS.50 .50 .63 .69 .75 .82 .94 1.05 1.36 1.36 1.70 1.82 2.31 2.56

L.85 .85 1.14 1.20 1.50 1.54 1.77 1.94 1.86 2.07 2.51 2.79 3.29 3.73

W.38 .38 .45 .51 .60 .62 .73 .82 1.17 1.17 1.41 1.48 1.94 2.19

RANGE FOR EQUAL RUN AND TAP12 STR. - 10 STR. 10 STR. - 8 STR. 8 STR. - 6 SOL. 8 STR. - 6 SOL. 8 STR. - 4 SOL. 8 STR. - 4 SOL. 6 STR. - 2 SOL. 6 STR. - 2 SOL. 6 STR. - 2 STR. 4 STR. - 1/0 STR. 2 STR. - 2/0 STR. 1 STR. - 3/0 STR. 1 STR. - 250 1/0 STR. - 350 2/0 STR. - 500 4/0 STR. - 750 300 - 1000

SOL.#10 #8 #6 #6 #4 #4 #2 #2 #1 2/0 3/0 4/0

MAXIMUM RUN AND TAP STR. TYPE A TYPE D 3 #12 3 #12 3 #10 3 #10 3 #8 3 #8 3 #7 3 #5 7 #7 7 #5 19 #8 19 #6 19 #5 8A 8A 6A 6A 4A 4A 3A 2A 9-1/2D 9-1/2D 8D 8D 6D 6D 5D 4D

165

275 385 500 650 825 1000 1100

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations.

See note page A-2 * Not UL or CSA Listed ** UL Rated for direct burial.

TYPE SCSERVIT COVER HUG-A-BUGUsed indoors or outdoors, this compact, onepiece plastic SERVIT cover saves time and material, eliminates costly taping of splitbolts. Positive latch snaps easily and quickly over connector, ideal for tight quarters. Selfpositioning plastic fingers wrap around wires fully insulating joint. UL Listed for 600 volt indoor application with type KS. Three Covers accommodate a range of 6 SERVIT sizes through 2/0 Str.

CATALOG NUMBERSC4 SC2 SERVIT and cover combination can be ordered as follows: CKS4 KS20 with cover CKS2/0 KS26 with cover For other combinations, please contact factory. SC2/0

FOR USE WITHKS17, KS17-3, KS20 KSU17, KSU20 KS22, KS20-3, KS23, KS22-3, KSA6, KSA4, KSU22, KSU23 KS25, KS26, KSA2, KSA 1/0 KSU25, KSU26

BURNDYMechanicalTYPE KSUUNIVERSAL SERVIT For All Combinations of Copper, Alum., ACSR, AAAC, 5005, and SteelTin-plated, high strength copper alloy SERVIT with spacer. Spacer separates dissimilar conductors and provides long contact length that prevents high pressure point contacts between run and tap conductors. Use of PENETROX joint compound recommended with Aluminum and ACSR.486A Copper Only

A-5

CONDUCTOR MAXIMUM CONDUCTOR STEEL RECOMMENDED SOL. 3 STR. NOM TIGHTENING BWG BWG DIA. TORQUE in-lb.8 6 4 8 6 4 5/32 7/32 1/4 5/16 3/8 7/16 1/2 1/2 5/8 165 275 275 385 385 500 650 650 825

RUN CATALOG CROSS NUMBER FIG. FLATKSU17 KSU20 KSU22 KSU23 KSU25 KSU26 KSU27 KSU29 KSU31 KSU34 2 2 2 2 2 2 1 1 1 1 .62 .69 .74 .81 .93 1.04 1.38 1.38 1.69 2.00

TAP ACSR AAAC 5005 COPPER & ALUMINUM ACSR AAAC 5005

L.92 1.05 1.25 1.48 1.77 1.93 2.34 2.50 2.88

W

COPPER & ALUMINUM

.42 12 SOL. - 6 SOL. 8 (6-1) 12 SOL. - 6 SOL. 8 (6-1) .48 10 SOL. - 4 SOL. 6 (6-1) 10 SOL. - 4 SOL. 6 (6-1) .57 10 SOL. - 2 SOL. 6 (6-1) - 4 (7-1) 10 SOL. - 2 SOL. 6 (6-1) - 4 (7-1) .59 8 STR. - 2 STR. 3 (6-1) - 2 (6-1) 8 SOL. - 2 STR. 6 (6-1) - 2 (6-1) .70 2 STR. - 1/0 STR. 3 (6-1) - 1 (6-1) 10 STR. - 1/0 STR. 6 (6-1) - 1 (6-1) .79 1/0 STR. - 2/0 STR. 1 (6-1) - 1/0 (6-1) 8 STR. - 2/0 STR. 6 (6-1) - 1/0 (6-1) 1.12 1 STR. - 3/0 STR. 1 (6-1) - 2/0 (6-1) 8 SOL. - 3/0 STR. 8 (6-1) - 2/0 (6-1) 1.14 1 STR. - 250 2/0 (6-1) - 4/0 (6-1) 8 STR. - 250 6 (6-1) - 4/0 (6-1) 1.36 4/0 STR. - 350 3/0 (6-1) - 4/0 (6-1) 4 STR. - 350 4 (6-1) - 4/0 (6-1) 336 (30-7) - 477 3.12 1.47 400 - 500 2 STR. - 500 2 (6-1) - 477 (18-1) (18-1)

Accommodates compressed conductors within conductor ranges. See note page A-2

BURNDYMechanicalTYPE KSATRITAP SERVITA-6

For All Combinations of Aluminum to Aluminum, Aluminum to Copper and Copper to Copper, Aluminum Alloy Tin Plated PATENTED TRIANGULAR PENETRATION TECHNOLOGY CONTACT Features and Benefits No scratch brushing required. No oxide inhibitor required. Orients the conductor. Provides maximum pressure and assures a secure connection of run and tap conductors. Facilitates piercing the aluminum conductor surface oxides. UL 486B listed, 90C rated. Provides a low contact resistance. Provides equal coefficient of expansion Inhibits the reformation of oxides by producing a gas-tight seal. Provides improved retention of minimum to maximum conductor combinations.

CATALOG CROSS NUMBER FLATS LKSA6 KSA4 KSA2 KSA 1/0 KSA 2/0 KSA 4/0 *KSA 350 *KSA 500 .75 .81 .94 1.00 1.12 1.49 1.69 2.00

W

ALUM. TO ALUM., ALUM. TO COPPER, COPPER TO COPPER CONDUCTORS MAX. RUN TO MAX. TAP MIN. RUN TO MIN. TAP MAX. RUN TO MIN. TAP#6 STR. (.184) #4 STR. (.232) #2 STR. (.292) #1/0 STR. (.373) #2/0 STR. (.418) #6 STR. (.184) #4 STR. (.232) #2 STR. (.292) #1/0 STR. (.373) #2/0 STR. (.418) #4/0 STR. (.528) #10 SOL. (.102) #10 SOL. (.102) #8 SOL. (.129) #10 SOL. (.102) #6 SOL. (.169) #8 STR. (.146) #2 STR. COMPACT #8 SOL. (.129) (.268) #2 STR. COMPACT #8 STR. (.146) (.268) #2 STR. COMPACT #6 STR. (.184) (.268) #1/0 STR. COMPACT #4 STR. (.232) (.336) 400 KCMIL #2 STR. COMPACT COMPACT (.659) (.268) #6 STR. (.184) #4 STR. (.232) #2 STR. (.292) #1/0 STR. (.373) #2/0 STR. (.418) #4/0 STR. (.528) #350 KCMIL (.681) #500 KCMIL (.813) #10 SOL. (.102) #10 SOL. (.102) #8 SOL. (.146) #8 SOL. (.129) #8 STR. (.146) #6 STR. (.184) #4 STR. (.232) #2 STR. COMPACT (.268)

RECOMMENDED TIGHTENING TORQUE in-lb165 165 275 385 385 500 650 825

1.28 .56 1.38 .62 1.58 .69 1.92 .75 1.92 .88

2.54 1.13 #4/0 STR. (.528)

3.24 1.50 350 KCMIL (.681) 350 KCMIL (.681) 3.62 1.73 500 KCMIL (.813) 500 KCMIL (.813)

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations. * Not CSA listed. ** No scratch brushing or oxide inhibiting compounds required for insulated 90 C max. rated conductor for N.E.C. applications.

BURNDYMechanicalTYPE KVSOKLIP Mechanical Connector For Copper & CopperweldCompact, two-piece, high strength, high copper alloy BURNDY OKLIP recommended for heavy duty connections. Neoprene rings hold DURIUM bolts in place during installation. Installed with ordinary wrench. A-7

CONDUCTOR COPPER CATALOG NUMBERKVS26 KVS28 KVS31 KVS34 KVS40 KVS44

RUN2 STR. - 2/0 STR. 1/0 STR. - 4/0 STR. 250 - 350 400 - 500 400 - 800 500 - 1000

TAP6 SOL. - 2/0 STR. 10 STR. - 4/0 STR. 10 STR. - 350 10 STR. - 500 3/0 STR - 800 3/0 STR. - 1000See note page A-2

SOL.3/0 4/0

COPPERWELD MAX. RUN AND TAP STR.7 #8 7 #6 19 #8 19 #6 19 #5

TYPE V V3/0 V250 V350

RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500 500

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations.

TYPE KVSUUNIVERSAL OKLIP Mechanical Connector For All Combinations of Copper, Aluminum, ACSR, AAAC & 5005Compact, high strength, tin plated copper alloy two-piece connector with spacer and tinplated silicon bronze DURIUM hardware. Recommended for heavy duty connections. Spacer separates dissimilar conductors and provides long contact length. Neoprene ring prevents loss of shorter bolt during installation. Longer peened bolt permits swivel action for easier installation. Use of PENETROX joint compound recommended with aluminum and ACSR.

CONDUCTOR RUN ACSR, AAAC, & 5005 RUN TAP COPPER COPPER ACSR, SOL., SOL., AAAC, COPPERWELD STEEL COPPERWELD STEEL COPPER & ALUM. & 5005 SOL., NOM. DIA. SOL., NOM. DIA. H6 STR. - 2/0 STR. 6 STR. - 4/0 STR. 6 - 350 4 - 500 4/0 - 800 4/0 - 1000 6 - 2/0 6 - 4/0 6 - 300 5 - 397.5 3/0 - 715.5 4/0 - 900 1 - 3/0 2/0 - 4/0 5/16 - 7/16 3/8 - 1/2 9/16 - 5/8 3/4 - 3/4 3/4 - 1 7/8 - 1-1/8 #6 - 3/0 #6 - 4/0 #6 - 4/0 #4 - 4/0

TAP

CATALOG NUMBER COPPER & ALUM.KVSU26 KVSU28 KVSU31 KVSU34 KVSU40 KVSU44

J

L

W

RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500

2 STR. - 2/0 STR. 3 - 2/0 1/0 STR. - 4/0 STR. 1/0 - 4/0 250 - 350 4/0 - 300 400 - 500 336.4 - 397.5 400 - 800 4/0 - 800 500 - 1000 4/0 - 1000

3/16 - 7/16 2 5/16 1 1-1/2 5/32 - 1/2 2-3/8 3/8 1-1/8 1-3/4 3/16 - 5/8 2-5/8 1/2 1-3/8 2-1/8 7/32 - 3/4 3 1/2 1-1/2 2-1/4 1/2 - 1 3-1/2 1/2 1-5/8 2-1/2 1/2 - 1-1/8 4 3/8 2 3

Accomodations compressed conductors within diameter range. See note page A-2

BURNDYMechanicalTYPE KVSWOKLIPA-8

Mechanical Connector For Copper and Copperweld.Similiar to OKLIP Type KVS except for a high copper alloy spacer that separates run and tap conductors. Provides high contact pressure, confines conductor strands, and assures vibration-proof connection. Longer peened bolt, permits swivel action for easier installation. Silicon bronze DURIUM hardware.

CATALOG NUMBERKVSW26 KVSW28 KVSW31 KVSW34 KVSW40 KVSW44See note page A-2

CONDUCTOR RUN2 STR. - 2/0 STR. 1/0 STR. - 4/0 STR. 250 - 350 400 - 500 400 - 800 500 - 1000

TAP6 SOL. - 2/0 STR. 6 SOL. - 4/0 STR. 4 SOL. - 350 4 STR. - 500 4/0 - 800 250 - 1000

RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500 500

TYPE KVS-AALUMINUM OKLIP Mechanical Connector For All Combinations of Copper, Aluminum, ACSR, AAAC and 5005Three-piece, high-conductivity, non-copper bearing aluminum alloy connector with thick spacer and aluminum hardware. Hardware in KVS26A and KVS28A is stainless steel. Recommended for heavy duty dissimilar metal applications. Spacer separates conductors and provides long contact length. Belled entrances prevent chafing, permit easier assembly of conductors. Longer peened bolt permits swivel action for easier installation. Neoprene ring prevents loss of shorter bolt. PENETROX joint compound recommended with aluminum and ACSR.

CONDUCTOR RUN CATALOG NUMBERKVS26A KVS28A KVS31A KVS34A KVS40A KVS44A

TAP ACSR, AAAC, & 50054 - 2/0 1/0 - 4/0 4/0 - 336.4 336.4 - 397.5 336.4 - 715.5 397.5 - 900

COPPER, & ALUM.2 STR. - 2/0 STR. 1/0 STR. - 4/0 STR. 250 - 350 400 - 500 400 - 800 500 - 1000

COPPER, & ALUM.10 STR. - 2/0 STR. 10 STR. - 4/0 STR. 6 STR. - 350 4 STR. - 500 3/0 STR. - 800 3/0 STR. - 1000

ACSR, AAAC & 50056 - 2/0 6 - 4/0 6 - 336.4 5 - 397.5 3/0 - 715.5 3/0 - 900

RECOMMENDED TIGHTENING TORQUE in-lb180 240 300 300 300 480

Accommodates compressed conductors within diameter range. See note page A-2

THESE CONNECTORS CAN ACCOMMODATE ACSR CONDUCTORS OVER ARMOR ROD WITHIN THE DIAMETER RANGE INDICATED. APPLICATION OVER ARMOR ROD

CONDUCTOR RANGE BY DIAMETER CATALOG MAX. RUN & NUMBER MIN. RUN DIA. MIN. TAP DIA. TAP DIA.KVS26A KVS28A KVS31A KVS34A KVS40A KVS44A .281 .360 .565 .728 .728 .806 .116 .116 .184 .216 .470 .470 .447 .564 .681 .814 1.036 1.162

H2-1/4 3 3-1/16 3-9/16 4-1/16 4-7/8

J5/16 3/8 1/2 1/2 1/2 5/8

L1-1/4 1-5/8 1-15/16 2-5/16 2-7/16 2-1/2

W1-5/8 2-1/16 2-7/16 2-5/8 2-7/8 3-1/8

BURNDYMechanicalTYPE QPXVERSITAP Parallel Clamp For Copper, Copperweld, CopperweldCopperThe VERSITAP Type QPX is recommended for Tee, Cross, Parallel, Butt and Tap connections. Range-taking, only 10 connectors required to accommodate conductor sizes from #6 Str. to 1000 kcmil. Edges are rounded for easy taping. Made of high strength, high-conductivity copper alloy and silicon bronze DURIUM hardware. * For various configurations, see page A-10. A-9

Fig. 1

Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb 150 250 375

CATALOG NUMBERQPX2C2C QPX282C QPX2828 QPX342C QPX3428 QPX3434 QPX442C QPX4428 QPX4434 QPX4444

COPPER CONDUCTOR RUN TAP6 STR. - 2 STR. 1 STR. - 4/0 STR. 250 - 500 6 STR. - 2 STR. 6 STR. - 2 STR. 1 STR. - 4/0 STR. 6 STR. - 2 STR. 1 STR. - 4/0 STR. 250 - 500 6 STR. - 2 STR. 1 STR. - 4/0 STR. 250 - 500 500 - 1000

FIG. NO.

H1-1/2 2-1/16

J5/16 3/8 5/16 3/8 5/16 3/8

L1-5/16 1-13/16 1-3/8 1-3/4 2-1/16 1-3/8 1-13/16 2-1/16 2-5/8

W1-3/8 1-9/16 1-13/16 1-7/8 2-1/16 2-3/16 2-1/4 2-7/16 2-9/16

1

2-3/8 2-3/4 3 2-11/16 2-7/8 3-1/16 3-7/16

2 1 2

500 - 1000

500

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor combinations. See note page A-2.

CONDUCTOR RUN CATALOG NUMBERQPX2C2C QPX282C QPX2828 QPX342C QPX3428 QPX3434 QPX442C QPX4428 QPX4434 QPX4444

TAP COPPERWELD COPPER8A - 4A 3A - 3/0 V 3A - 3/0 V 4/0 EK

COPPERWELD5 SOL. - 3 #7 7 #9 - 7 #5 7 #9 - 7 #5 19 #9 - 19 #6

COPPERWELD5 SOL. - 3 #7 5 SOL. - 3 #7 7 #9 - 7 #5 5 SOL. - 3 #7 7 #9 - 7 #5 19 #9 - 19 #6 5 SOL. - 3 #7 7 #9 - 7 #5 19 #9 - 19 #6 19 #6

COPPERWELD COPPER8A - 4A 8A - 4A 3A - 3/0 V 8A - 4A 3A - 3/0 V 4/0 EK 8A - 4A 3A - 3/0 V 4/0 EK

19 #6

BURNDYMechanicalTYPE QPX-YUNIVERSAL VERSITAPA-10

Universal Parallel Clamp For Copper and AluminumHigh copper alloy cast connector, tin-plated for use with copper or aluminum cable. Makes parallel, tap, tee, cross or end-to-end connections. Edges rounded for easy taping. PENETROX joint compound recommended.

Fig. 1CONDUCTOR ALUMINUM OR COPPER RUN TAP6 STR. - 2 STR. 1/0 STR. - 4/0 STR. 1/0 STR. - 4/0 STR. 250 - 500 750 - 1000 6 STR. - 2 STR. 6 STR. - 2 STR. 1/0 STR. - 4/0 STR. 6 STR. - 2 STR. 1/0 STR. - 4/0 STR. 200 - 500 750 - 1000

Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb 150 250 375 500

CATALOG NUMBERQPX2C2C-Y QPX282C-Y QPX2828-Y QPX342C-Y QPX3428-Y QPX3434-Y QPX4444-Y

FIG. NO.1 1 2 2

H1-5/8 1-7/8 2 2-1/4 2-1/2 2-7/8 3-7/8

J5/16 3/8 5/16 3/8 1/2

L1-1/2 2 1-1/2 2 2-1/2 3-1/2

W1-5/8 1-7/8 2-1/8 2-1/8 2-1/2 2-5/8 3-1/2

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7 4, 7-5 7-6 for smaller conductor combinations. See note page A-2.

APPLICATION VARIATIONSPARALLEL TAP CROSS

TEE SPLICE

BURNDYMechanicalTYPE KPASCRULUG For Copper CableHigh copper alloy tin-plated terminal for joining a wide range of cable to equipment pads or terminal blocks. Especially good in light industrial applications. The tongue and body are a one-piece design. The pressure bar equalizes pressure over the conductor and prevents the screw from cutting into the cable. A-11

Fig. 1STUD HOLE SIZE.10 1/4 5/16 3/8 1/2

Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb12 45 180 250 375

CATALOG NUMBERKPA8C KPA4C KPA25 KPA28 KPA34

WIRE RANGE8 STR. - 14 SOL. 14 SOL. - 4 STR. 4 STR. - 1/0 STR. 1/0 STR. - 4/0 STR. 4/0 STR. - 500 kcmil

FIG. NO.1 1 2 2 2

C.38 .50 .75 .97 1.38

D.47 .59 .81 1.12 1.38

H.72 .94 1.25 1.66 2.44

K.21 .27 .33 .40 .54

L.95 1.20 1.70 2.29 3.14

N.22 .30 .41 .53 .75

T.06 .06 .10 .13 .20

NOTE: For unplated version add UNPL suffix.

BURNDYMechanicalTYPE KPA-UPSCRULUGA-12

FOR COPPER CABLEHigh copper alloy terminal for joining a wide range of cable to equipment pads or terminal blocks. Plain copper finish.

Features and Benefits One piece design. Superior torque and pull out performance. Convenient range taking design. Reduces catalog numbers. One catalog number accommodates several conductor sizes. High conductivity copper alloy. Long lasting, reliable contact. Compact design. Easy to use. Slot Robertson screw, hex head, hex socket bolt. No special installation tools required. Eliminates over-torquing/potential conductor damage.

Fig. 1CATALOG WIRE NUMBER RANGEKPA8CUP KPA4CUP 14 SOL. 6 STR. 14 SOL. 4 STR.

Fig. 2

Fig. 3RECOMMENDED TIGHTENING TORQUE in-lb35 45

FIG. NO.1

C0.38 0.50

D0.51 0.71

H0.81 1.00

K0.20 0.28

STUD HOLE SIZE#10 1/4

L1.01 1.28

N0.24 0.33

T0.07 0.07

HARDWARE1/4 Dia. Slot Robertson 5/16 Dia. Slot Robertson

NOTE: For tin plating drop -UP suffix and add -TP suffix (example: KPA4CTP). For use in grounding applications with a green screw - contact factory. Listed for grounding per UL467.

BURNDYMechanicalTYPE KLUSCRULUG FOR COPPER CABLE OFFSET TONGUE NON-PLATEDHigh copper alloy terminal with offset tongue for joining a wide range of cable to equipment pads or bar. Easy to install with screwdriver or wrench. Connector is reusable. Plain copper finish. A-13

Features and Benefits Convenient range-taking design. Reduces catalog numbers. One conductor accommodates several conductor sizes. High conductivity copper alloy. Long lasting reliable contact. Compact design. Easy to use. Reduces labor time. Slot Robertson screw, hex head/hex socket bolt. No special installation tools required. Eliminates over-torquing/potential conductor damage.

Fig. 1CATALOG NUMBER CONDUCTOR

Fig. 2

Fig. 3STUD STRIP HOLE QUANTITY/ LENGTH SIZE PACKAGE (IN.) #6 #10 1/4 1/4 3/8 5/16 3/8 3/8 100 100 100 25 12 12 6 3 7/16 5/8 3/4 15/16 1 1-5/16 1-5/8 1-5/32

RECOMMENDED FIG. B C K L N T TIGHTENING NO. (MM/IN) (MM/IN) (MM/IN) (MM/IN) (MM/IN) (MM/IN) TORQUE IN LBS. 3 6.4 .26 8.4 .33 11.8 .46 16.9 .63 18.0 .71 19.6 .77 25.2 1.0 29.6 1.16 8.0 .31 10.0 .39 12.0 .47 16.9 .63 19.0 .75 26.2 .99 26.2 .99 38.0 1.60 3.6 .14 6.0 .20 6.7 .26 6.5 .26 10.0 .39 8.5 .33 10.0 .39 10.0 .39 26.0 1.02 31.6 1.24 39.6 1.56 50.5 1.99 66.0 2.20 65.0 2.56 72.0 2.83 104.0 4.09 6.3 .21 5.6 .22 6.4 .25 10.8 .43 11.0 .43 13.0 .51 13.1 .52 23.0 .91 1.9 .07 1.8 .07 2.1 .08 2.7 .11 4.0 .16 3.1 .12 3.1 .12 4.5 .18 20 45 50 50 124 204 325 375

HARDWARE No. 8 - 32 Slotted Round Machine Screw 1/4 UNF Slotted Set Screw 5/16 UNF Slotted Set Screw 3/8 UNF Slotted Set Screw 3/8 UNF Socket Set Screw 7/16 UNF Socket Set Screw 5/8 UNF Slotted Set Screw 5/8 UNF Slotted Set Screw

KLU25 14 Sol. 1.63 (0.64) Dia. to KLU25TP 10 Sol. 2.60 (1.02) Dia. CU KLU35 14 Sol. 1.63 (.0641) Dia. to KLU35TP 6 Str. 4.67 (.184) Dia. CU KLU70 8 Sol. 3.28 (.129) Dia. to KLU70TP 2 Str. 7.42 (.292) Dia. CU KLU125 2 Str. 7.42 (.292) Dia. to KLU125TP 1/0 Str. 9.44 (.372) Dia. CU KLU175 4 Str. 5.89 (.232) Dia. to KLU175TP 3/0 Str. 11.94 (.470) Dia. CU KLU225 2 Str. 7.42 (.292) Dia. to KLU225TP 4/0 Str. 13.4 (.528) Dia. CU KLU300 1/0 Str. 9.44 (.372) Dia. to KLU300TP 350 MCM 17.30 (.681) Dia. CU KLU400 1/0 Str. 9.44 (.372) Dia. to KLU400TP 500 MCM 207 (.813) Dia CU

2

1

2

NOTES: Suffix -TP on catalog number denotes tin plate (example: KLU400TP). 2 Material: Copper alloy.

BURNDYMechanicalTYPE KAKA-LUGA-14

For Copper CableCompact, economical, high copper alloy terminal for joining a wide range of cable to equipment pads or terminal blocks.

Fig. 1CATALOG NUMBERKA8C KA4C KA25 KA25-2TC 38 KA28 KA34

Fig. 2STUD HOLE SIZE#10 1/4 3/8 3/8 3/8 1/2

Fig. 3RECOMMENDED TIGHTENING TORQUE in-lb25 45 200 200 275 375

CONDUCTOR14 SOL. - 8 STR. 14 SOL. - 4 STR. 4 STR. - 1/0 STR. 4 STR. - 1/0 STR. 1 STR. - 4/0 STR. 4/0 STR. - 500

FIG. NO.1 2 3 2

C3/8 9/16 3/4 3/4 15/16 1-3/8

H5/8 3/4 15/16 15/16 1-1/4 2-3/32

J#12 5/16 1/2 1/2 5/8 13/16

K7/32 9/32 27/64 27/64 27/64 9/16

L13/16 1-1/8 1-11/16 2-13/16 1-15/16 2-9/16

N3/16 1/4 3/8 3/8 7/16 9/16

T3/32 7/64 1/8 1/8 3/16 9/32

Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes.

TYPE EAVERSILUG For Copper CableCompact, high copper alloy terminal for joining a wide range of cable to equipment pads or bar. Clamping element adjustable to several angles. One-wrench installation.

CATALOG NUMBEREA2C EA25 EA28 EA28-2N EA34 EA34-2N

CONDUCTOR8 SOL. - 2 STR. 2 STR. - 1/0 STR. 1/0 STR. - 4/0 STR. 250 - 500

NO. OF HOLES IN PAD1 1 1 2 NEMA 1 2 NEMA

C13/16 7/8 1-1/16 1-3/8

D1-1/16 1-1/8 1-3/8 3-5/8 1-5/8 3-5/8

E 1-3/4 1-3/4

H1-3/8 1-7/16 1-3/4 2-1/4

K7/16

STUD HOLE SIZE3/8 3/8 3/8 1/2 1/2 1/2

L2-1/2 2-11/16 3-3/16 5-1/8 4 5-5/8

N13/32 7/16 17/32 5/8 13/16 5/8

T1/4 5/16 3/8

RECOMMENDED TIGHTENING TORQUE in-lb150 180 250 375

9/16

* N indicates NEMA standard stud holes. Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes.

BURNDYMechanicalTYPE BGBLLAY-IN QIKLUG *UL LISTED 90 C, 600 VThe Lay-In QIKLUG, Type BGBL is manufactured from high strength 6061-T6 aluminum, and is ideally suited for grounding and bonding applications accommodating both copper and aluminum conductor sizes #14 AWG to 250 kcmil. A-15

Fig. 1

Features and Benefits * UL 486B listed, AL9CU rated. For copper and aluminum conductor combinations up to 90 C, 600 Volt applications. UL Recognized for grounding and bonding. Ensures reliability. Electro-tin plated. Provides low contact resistance. Lay-in feature. Eases installation.

Fig. 2

DIMENSIONS CATALOG NUMBER*BGBL-4 BGBL-1/0 BGBL-250

FIG NO.1 1 2

CONDUCTOR RANGE4 - 14 AWG 1/0 - 14 AWG 250 kcmil - 6

C.39 [10] .63 [16] .88 [22]

D.62 [16] .80 [20] 1.18 [30]

E.48 [12] .83 [21] 1.00 [30]

H REF.79 [20] 1.16 [29] 1.72 [44]

J1/4 - 28 3/8 - 24 7/16 - 18

K DIA..22 [6] .28 [7] .28 [7]

L1.10 [28] 1.63 [41] 2.18 [55]

N.20 [5] .44 [11] .45 [11]

T.13 [3] .19 [5] .25 [6]

HEX SIZESLOT SLOT 7/32

NOTE: PEN-A PENETROX inhibitor is recommended for all aluminum terminations.

TYPE CL50-1COPPER LAY-IN QIKLUG FOR COPPERThe Lay-In QIKLUG is manufactured from high strength pure electrolytic copper to ensure maximum strength and conductivity. UL467 Listed for direct burial in earth or concrete. The open-faced design allows for fast lay-in of the conductor without the need for cutting or breaking.

CATALOG NUMBERCL50-1

WIRE RANGE COPPER#14 - #4 CU

STUD HOLE#10

BURNDYMechanicalTYPES QA, QQAQIKLUGA-16

For Copper CableType QA heavy duty, compact, high copper alloy terminal for joining a wide range of cable to equipment pads or bar. Fast one-wrench installation. Type QQA heavy duty, high copper alloy terminal for joining cable to equipment pads or bar. Twin clamping elements secure joint vibration and flexing. One-wrench installation.

Type QA

Type QQA

CATALOG NUMBER* CONDUCTOR TYPE QA TYPE QQA COMMERCIAL NAVYQA8C-B QA8C-2B QA4C-B QA4C-2B QA1C-B QA1C-2B QA26-B QA26-2B QA28-B QA28-2B QA28-2N* QA31-B QA31-2B QA31-2N* QA34-B QA34-2B QA34-4B QA34-2N* QA40-B QA40-2N* QQA8C QQA8C-2 QQA4C QQA4C-2 QQA1C QQA1C-2 QQA26 QQA26-2 QQA28 QQA28-2N* QQA31 250 - 350 QQA31-2N* QQA34 400 - 500 QQA34-2N* QQA40-2N* QQA40-4N 600 - 800 650 - 800 400 - 500 250 - 350 14 SOL. - 8 STR. 8 STR. - 4 STR. 4 STR. - 1 STR. 4 - 14 23 - 40 50 - 75

NO. OF HOLES IN PAD1 2 1 2 1 2 1 2 1 2 2 NEMA 1 2 2 NEMA 1 2 4 2 NEMA 1 2 NEMA 4 NEMA 1 2 NEMA 4 NEMA 1 2 NEMA

C9/16

D

E&F

H

K

STUD HOLE SIZE#10 1/4 5/16 3/8

L

LL

N9/32 5/16 5/16 11/32

T5/32 3/16

RECOMMENDED TIGHTENING TORQUE in-lb75 110 150

5/8

1/0 STR - 2/0 STR. 100 - 125 3/0 STR. - 4/0 STR. 150 - 200

13/16 1

1-3/16 1-3/8 1-7/8 1-3/8 1-5/8 3 1-7/8

9/16 11/16 1-1/4 5/8 7/32 5/8 3/4 1-3/16 5/8 9/32 3/4 1 1-9/16 7/8 11/32 1 1-3/16 1-15/16 1 13/32 1-1/16 2 1 1-5/16 3-1/8 1-3/4 9/16 1-3/8 17/32 1-31/32 1 1-11/16 7/16 3 1-3/4 9/16 1-5/8 17/32 2 13/32 1 2 1-15/16 7/16 3-3/32 1-3/4 9/16 1-7/8 11/16 2-7/16 3 1-3/4 9/16 1-3/4 1-3/4 2-3/4 3-1/8 11/16 9/16 13/16 9/16

1/2 3/8 1/2 3/8 1/2 5/8 1/2 5/8 1/2 3/4 1/2

QA44-B QA44-2N* QQA44-2N QA44-4N* QQA44-4N* QA46-B QA46-2N*

850 - 1000 1100 - 1500

1000 1300

2 3 3 3-1/16 2-1/8 2-1/8 3

1-3/8 2-5/16 2 3 1-7/16 2-3/8 2 2-15/16 1-3/4 2-13/16 2-9/16 3-5/8 2 3-3/16 3 4-3/16 2-1/4 3-9/16 3-9/16 4-5/16 5-5/8 2-11/36 4-1/8 3-3/8 4-7/16 5-7/8 3-3/16 4-7/8 3-9/16 3-1/2 4-11/16 6-9/32 3-11/16 4-14/16 7-3/32 3-15/16 5 4-3/8 5-1/4 7-1/8

7/32 7/16 17/32 7/16 5/8 11/16 7/16 5/8 13/16 7/16 7/16 5/8 27/32 5/8 1 5/8 1-1/16 5/8 1/2 9/16 600 1/4 180 250

5/16

325

5/16

375

3/8 500

* N indicates NEMA standard stud holes. All 4N items See note page A-2

BURNDYMechanicalTYPE Q2AQIKLUG For Copper CableCompact, high copper alloy terminal for joining two cables to equipment pads or bars. Each element accommodates a wide range of cable. One-wrench installation. A-17

CATALOG NUMBER*Q2A1C-2 Q2A26-2N Q2A28-2N Q2A28-4N Q2A31-2N Q2A31-4N Q2A34-2N Q2A34-4N Q2A40-2N Q2A40-4N Q2A44-4N Q2A46-4N

CONDUCTOR4 STR. - 1 STR. 1/0 STR. - 2/0 STR. 3/0 STR. - 4/0 STR. 250 - 350 400 - 500 600 - 800 850 - 1000 1100 - 1500

NO. OF HOLES IN PAD2 2 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 4 NEMA

C1-1/2 1-5/8 1-7/8 3 2-3/8 3 2-1/2 3 3 3-1/4 3-1/2

D1-7/8

E&F1 3/4

H1-1/16 1-3/16 1-3/8

K7/16

STUD HOLE SIZE3/8

L2-7/8 4-3/16 4-3/8 4-1/2

N7/16

T7/32 7/32 1/4 5/16

W1-13/16 1-15/16 1-15/16 2-1/8 2-1/8 3 3 3-3/4 3-3/4 4-11/32 4-11/32 5

RECOMMENDED TIGHTENING TORQUE in-lb 150 180 250 325 375 500 600

3-1/8 1-3/4

1-11/16 2 2-7/16 9/16 1/2

4-11/16 5 5-1/4 5-1/2

5/8

3/8 7/16 1/2 11/16

3-1/4

2-3/4 3-1/8

* N indicates NEMA standard stud holes. All 4N items See note page A-2

TYPE Q3AQIKLUG For Copper CableCompact, high copper alloy terminal for joining three cables to equipment pads or bar. Each element accommodates a wide range of cable. One-wrench installation.

CATALOG NUMBER*Q3A28-2N Q3A28-4N Q3A31-2N Q3A31-4N Q3A34-2N Q3A34-4N Q3A40-4N Q3A44-4N Q3A46-4N

CONDUCTOR3/0 STR. - 4/0 STR. 250 - 350 400 - 500 600 - 800 850 - 1000 1100 - 1500

NO. OF HOLES IN PAD2 NEMA 4 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 4 NEMA 4 NEMA

C1-7/8 3 2-3/8 3 2-1/2 3 3-1/4 3-1/2

D

E&F

H1-3/8

K

STUD HOLE SIZE

L4-5/16 4-3/8 4-7/16

N

T1/4 5/16

W3-3/16 4-1/16 4-9/16 5-13/16 6-5/8 7-7/8

RECOMMENDED TIGHTENING TORQUE in-lb250 325 375 500 600

3-1/8 1-3/4

1-11/16 1-15/16 2-7/16 2-3/4 3-1/8 9/16 1/2

4-3/4 5 5-1/4 5-1/2

5/8

3/8 7/16 1/2 11/16

3-1/4

* N indicates NEMA standard stud holes.

BURNDYMechanicalTYPE QBQIKLUGA-18

For Copper CableCompact, high copper alloy side entrance terminal for joining a range of cable at right angles to terminal blocks. One-wrench installation.

CATALOG NUMBER*QB8C QB4C QB1C QB26 QB28 QB31-2N

CONDUCTOR14 SOL. - 8 STR. 8 STR. - 4 STR. 4 STR. - 1 STR. 1/0 STR. - 2/0 STR. 3/0 STR. - 4/0 STR. 250 - 350

NO. OF HOLES IN PAD1 1 1 1 1 2 NEMA

C9/16 11/16 13/16 1 13/16

D9/16 27/32 13/16 1 1-1/16 3-1/4

E 1-3/4

H7/8 13/16 1 1-1/32 1-5/16 1-11/16

K7/32 9/32 13/32 9/16

STUD HOLE SIZE#10 1/4 3/8 1/2

L1-1/8 1-3/8 1-1/2 1-13/16 2-1/16 4-1/2

N9/32 11/32 7/16 17/32 5/8

T5/32 1/4 7/32 1/4 5/16

RECOMMENDED TIGHTENING TORQUE in-lb 75 110 150 180 250 325

N indicates NEMA standard stud holes.

TYPE Q2BQIKLUG For Copper CableCompact, high copper alloy terminal for joining two cables at right angles to a single terminal block. Each element accommodates a range of cable. One-wrench installation.

CATALOG NUMBER*Q2B28-2N Q2B31-2N Q2B40-4N

CONDUCTOR3/0 STR. - 4/0 STR. 250 - 350 600 - 800

NO. OF HOLES IN PAD2 NEMA 2 NEMA 4 NEMA

C1-7/8 2-3/8 3

D3-1/8 3-3/16 3-1/16

E&F1-3/4 1-11/16 1-3/8

H1-3/8 1-3/8 2-5/16

K9/16

STUD HOLE SIZE3/8 1/2 1

L5-3/16 5-7/8 6-11/16

N5/8

T1/4 5/16 7/16

RECOMMENDED TIGHTENING TORQUE in-lb250 325 500

N indicates NEMA standard stud holes. All 4N items See note page A-2

BURNDYMechanicalTYPE QDAQIKLUG For Copper CableCompact, high copper alloy terminal for joining a wide range of cable to equipment studs. Provides low contact resistance when gripped between two contact nuts. Onewrench installation. A-19

CATALOG NUMBERQDA8C QDA4C QDA1C QDA26 QDA28 QDA31 QDA34 QDA40

CONDUCTOR COMMERCIAL NAVY14 SOL. - 8 STR. 8 STR. - 4 STR. 4 STR. - 1 STR. 1/0 STR. - 2/0 STR. 3/0 STR. - 4/0 STR. 250 - 350 400 - 500 600 - 800 3 - 14 23 - 40 50 - 75 100 - 125 150 - 200 250 - 350 400 - 500 650 - 800

C1 1-1/4 1-1/2 1-7/8 2-1/8

H11/16 3/4 1 1-3/16 1-5/16 1-11/16 2 2-5/16

K7/16 9/16 11/16 13/16 1-1/16

STUD HOLE SIZE3/8 1/2 5/8 3/4 1

L1-7/8 2-3/16 2-1/2 2-5/8 3 3-5/8 4-3/16

T3/16 7/32 9/32 5/16 3/8

RECOMMENDED TIGHTENING TORQUE in-lb75 110 150 180 250 325 375 500

TYPE QR QIKLINKSPLICE OR REDUCER For Copper Cable to CableHigh copper alloy splicer/reducer for joining a range of cable end to end. Neat, compact easy to tape installation. One-wrench installation.

CATALOG NUMBERQR4C QR1C QR26 QR28 QR31 QR34 QR40See note page A-2.

CONDUCTOR EITHER SIZE8 STR. - 4 STR. 4 STR. - 1 STR. 1/0 STR. - 2/0 STR. 3/0 STR. - 4/0 STR. 250 - 350 400 - 500 600 - 800

H3/4 1-1/16 1-3/16 1-3/8 1-11/16 1-15/16 2-7/16

L1-11/16 1-15/16 2-1/8 2-3/8 2-5/8 3-1/16 3-5/8

W5/8 11/16 13/16 1 1-1/4 1-7/16 1-7/8

RECOMMENDED TIGHTENING TORQUE in-lb110 150 180 250 325 375 500

BURNDYMechanicalTYPE VTVARITAP T-CONNECTORA-20

For Copper Cable to CableHigh copper alloy T-connector for cable run, cable tap. V-bolt clamping elements accommodate large range of cable and are particularly suited for extra flexible cable. One-wrench installation.

CATALOG NUMBERVT2C2C VT2525 VT2825 VT2828 VT3025 VT3030 VT3425 VT3428 VT3430 VT3434 VT4040 VT4425 VT4428 VT4834 VT4844 VT4848

CONDUCTOR RUN8 SOL. - 2 STR. 6 SOL. - 1/0 STR. 1/0 STR. - 4/0 STR. 1/0 STR. - 300

TAP8 SOL. - 2 STR. 6 SOL. - 1/0 STR. 6 SOL. - 1/0 STR. 1/0 STR. - 4/0 STR. 6 SOL. - 1/0 STR. 1/0 STR. - 300 6 SOL. - 1/0 STR. 1/0 STR. - 4/0 STR. 1/0 STR. - 300 300 - 500 500 - 800 6 SOL. - 1/0 STR. 1/0 STR. - 4/0 STR. 300 - 500 750 - 1000 1500 - 2000

H1-5/16 1-5/8 1-7/8

L2-5/16 2-5/8 3-1/8 3-1/16 3-3/8 3-5/16 3-11/16 3-1/2 3-5/8 3-3/4 4-1/2 4-5/16 4-1/8 5-1/4 5-3/4 6-1/4

W1-5/16 1-7/16 1-1/4 1-11/16 1-3/8 1-15/16 1-1/2 1-11/16 1-15/16 2-1/4 2-5/8 2 2 5 5 5

RECOMMENDED TIGHTENING TORQUE in-lb RUN TAP275 385 250 250 325 325 375 375 375 375 500 500 500 600 600 600 275 385 385 250 385 325 385 250 325 375 500 385 250 375 500 600

300 - 500 500 - 800 750 - 1000 1500 - 2000

2-5/16 2-9/16 2-7/8 4-1/4

See note page A-2

TYPE E-C-GTRANSFORMER TAP ADAPTER For CopperMulti-tap, range-taking cast copper alloy connector designed to take 2, 3 or 4 conductors from a single secondary transformer outlet.

CATALOG NO. OF CONDUCTOR A NUMBER CONDUCTORS SIZE DIA.E2C34G1 E3C34G1 E4C34G1 2 3 4 1/0 SOL. - 500 .78

D

H

J

L

W3-1/2 5-1/4 6-7/8

RECOMMENDED TIGHTENING TORQUE in-lb480

3-3/4 2-7/8

1/2-13 6-1/4

BURNDYMechanicalTYPE VA, VVAVARILUG For Copper CableHigh copper alloy terminal for joining a wide range of cable to equipment pads or bar. Particularly suitable for use on extra flexible cable. One-wrench installation. Type VVA, twin elements secure joint against vibration and flexing. Particularly recommended for use on extra flexible cables. One-wrench installation. A-21

Type VA

Type VVA

CATALOG NUMBER* TYPE VA TYPE VVAVA2C VA25 VA28 VA28-2N VA30 VA30-2N VA34 VA34-2N VA34-4N VA40 VA40-2N VA40-4N VVA2 VVA25 VVA28 VVA28-2N VVA30 VVA30-2N VVA34 VVA34-2N VVA34-4N VVA40 VVA40-2N VVA40-4N

CONDUCTOR8 SOL. - 2 STR. 6 SOL. - 1/0 STR. 1/0 STR. - 4/0 STR. 1/0 STR. - 300 300 - 500

NO. OF HOLES IN PAD1 1 2 NEMA 1 2 NEMA 1 2 NEMA 4 NEMA 1 2 NEMA 4 NEMA

C13/16 7/8

D

E&F 1-3/4 1-3/4 1-3/4 1-3/4 1-3/4 1-3/4

H1-1/2 1-7/8 2-1/4 2-3/16 3-11/32

K7/16 7/16 9/16 7/16 9/16 11/16 9/16 9/16

STUD HOLE SIZE3/8 1/2 3/8 1/2 5/8 1/2

L

LL

N

T

RECOMMENDED TIGHTENING TORQUE in-lb275 385 250 325 375

500 - 800

1-1/4 1-5/16 1-1/2 1-1/16 3-1/2 1-5/8 1-1/8 3-9/16 2 1-3/8 3-5/8 3 3-5/8 2-5/16 1-5/8 3-5/8 3 2-5/8

2-7/8

2-3/4 4-1/16 2-7/8 4-5/16 2-7/8 4-1/8 4-15/16 6-3/6 3-1/4 4-5/8 5-3/16 6-9/16 3-13/16 5-5/16 5-3/8 6-7/8 5-3/8 6-7/8 4-1/2 6-3/8 5-13/16 7-11/16 5-13/16 7-11/16

13/32 1/4 7/16 17/32 5/8 5/16 5/8 5/8 13/16 5/8 5/8 3/8 15/16 5/8 5/8

500

N indicates NEMA standard stud holes. All 4N items See note page A-2

BURNDYMechanicalTYPE HFB-P1A-22

BAR CLAMP ASSEMBLY COMPONENTS For Copper BarTo build your own high strength clamp assembly for multiple flat bar using type HFB-P1 bar clamps and clamping hardware, the following tables have been provided. The clamp assembly eliminates the need for drilling the flat bar and is used in indoor and outdoor applications.

BAR CLAMP BAR CATALOG RUN TAP NUMBER A AAHFB22P1 HFB33P1 HFB42P1 HFB44P1 HFB63P1 HFB66P1 HFB88P1 2.00 3.00 4.00 4.00 6.00 6.00 8.00 2.00 3.00 2.00 4.00 3.00 6.00 8.00

ONE CLAMP HALF J BOLT DIA. L3/8 3/8 3/8 1/2 1/2 5/8 3/4 4.38 4.38 5.75 5.75 7.75 8.12 10.50

W4.38 4.38 5.75 5.75 4.75 8.12 10.50

Z* * * * * * *

RECOMMENDED TIGHTENING TORQUE in-lb240 240 240 480 480 660 1990

*Z=Space between the bar clamp contact surfaces

COPPER BUS BAR WIDTH (INCHES) RUN-A TAP-AA2 3 4 4 6 6 8 2 3 2 4 3 6 8

BAR CLAMP ASSEMBLY COMPONENTS SILICON BRONZE CLAMPING HARDWARE BAR CLAMP QTY. CAT. NO.2 2 2 2 2 2 2 HFB22P1 HFB33P1 HFB42P1 HFB44P1 HFB63P1 HFB66P1 HFB88P1

BOLTS QTY.4 4 4 4 4 4 4

NUTS CAT. NO.38 X (*) HEB 38 X (*) HEB 38 X (*) HEB 50 X (*) HEB 50 X (*) HEB 62 X (*) HEB 75 X (*) HEB

QTY.4 4 4 4 4 4 4

CAT. NO.38CHEN 38CHEN 38CHEN 50CHEN 50CHEN 62CHEN 75CHEN

SPLIT LOCK WASHERS QTY. CAT. NO.4 4 4 4 4 4 4 38SW 38SW 38SW 50SW 50SW 62SW 75SW

Ordered separately from BURNDY. * See table below when ordering assembly clamping bolts to specify correct bolt length in Cat. #.

CLAMP NUMBERHFB22P1 HFB33P1 HFB42P1 HFB44P1 HFB63P1 HFB66P1 HFB88P1

J BOLT DIA.3/8 (-16) 3/8 (-16) 3/8 (-16) 1/2 (-13) 1/2 (-13) 5/8 (-11) 3/4 (-10)

WHEN Z = 1.253.00 3.00 3.00 3.25 3.25 3.50 3.75

WHEN Z = 1.503.25 3.25 3.25 3.50 3.50 4.00 4.00

BOLT LENGTH WHEN WHEN Z = 1.75 Z = 2.003.50 3.50 3.50 3.75 3.75 4.00 4.50 4.00 4.00 4.00 4.00 4.00 4.50 4.50

WHEN Z = 2.254.00 4.00 4.00 4.50 4.50 4.50 5.00

WHEN Z = 2.504.50 4.50 4.50 4.50 4.50 5.00 5.00

WHEN Z = 2.754.50 4.50 4.50 5.00 5.00 5.00 5.50

WHEN Z = 3.005.00 5.00 5.00 5.00 5.00 5.50 5.50

NOTE: When ordering assembly bolts specify correct bolt length in catalog number as indicated in table.

BURNDYMechanicalTYPE HFB-NBAR CLAMP TAP PAD ADAPTER For Copper BarHigh conductivity copper, tap pad adapter provides a NEMA drilled contact pad when assembled to the HFB-P1 clamps. Tap connections can be made from copper bus bar(s) without drilling, by bolting standard mechanical or compression terminal pads directly to the pre-drilled tap pad A-23

Fig. 1 Fig. 2CATALOG NUMBERHFB33-4N HFB44-4N HFB66-6N

FIG. NO.1 1 2

A-C3.00 4.00 6.00

E&F1.75 1.75 1.75

L7.00 9.12 11.31

N.62 1.12 1.12

USE WITH H CLAMP CATALOG NUMBER HFB33P1 HFB44P1 HFB66P1

H Clamp (two required per assembly) and hardware (asshown) not included with bar clamp tap pad, order separately.

BURNDYMechanicalTYPES KA-U, KKA-UUNIVERSAL TERMINALA-24

(One Conductor) For Aluminum and Copper ConductorsThese dual-rated one-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance.

Fig. 1

Fig. 2

AL9CU

Fig. 3

Fig. 4

CATALOG NUMBER*KA6U KA2U KA25U KA26U KA29U KA30U KA31U KA34U KA36U KA40U KA44U KKA31U-2N KA36U-2N KA40U-2N KA44U-2N

FIG. NO.1 1 1 2 2 2 2 2 2 2 2 3 4 4 4

WIRE RANGE ALUMINUM OR COPPER14 STR. - 6 STR. 14 STR. - 2 STR. 14 STR. - 1/0 STR. 6 STR. - 2/0 STR. 6 STR. - 250 6 STR. - 300 6 STR. - 350 4 STR. - 500 2 STR. - 600 300 - 800 500 - 1000 6 STR. - 350 2 STR. - 600 300 - 800 500 - 1000

STUD HOLE SIZE1/4

D.63 .63 .81 .81 .94 .94 1.03 1.50 1.72 1.69 1.69 3.16 3.22 3.03 3.03

L1.06 1.16 1.50 1.47 2.00 2.00 2.25 2.81 3.19 3.38 3.38 5.50 4.69 4.75 4.75

DIMENSIONS ** N W E.25 .31 .44 .47 .50 .50 .88 .88 .78 .88 .88 .63 .63 .63 .63 .50 .50 .63 .63 1.00 1.00 1.13 1.51 1.50 1.75 1.75 1.25 1.50 1.75 1.75 1.75 1.75 1.75 1.75

T.09 .10 .19 .19 .25 .25 .25 .31 .44 .50 .50 .38 .44 .50 .50

** H.50 .55 .80 .80 1.13 1.12 1.25 1.58 1.56 1.94 1.94 1.50 1.57 1.94 1.94

RECOMMENDED TIGHTENING TORQUE in-lb45 50 50 120 275 275 375 500 500 500 600 375 500 500 600

5/16 3/8 1/2

1/2

* "N" indicates NEMA standard stud holes. Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. ** Maximum dimension.

BURNDYMechanicalTYPE K2A-UUNIVERSAL TERMINAL (Two Conductor) For Aluminum and Copper ConductorsThese dual-rated two-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance. A-25

Fig. 1

Fig. 2

Fig. 3

CATALOG NUMBER*K2A25U K2A26U K2A29U K2A31U K2A36U K2A40U K2A44U K2A31U-2N K2A36U-2N K2A40U-2N K2A44U-2N

FIG. NO.1 2 2 2 2 2 2 3 3 3 3

WIRE RANGE ALUMINUM OR COPPERTwo: 14 STR. - 1/0 STR. Two: 14 STR. - 2/0 STR. Two: 6 STR. - 250 Two: 4 STR. - 350 Two: 2 STR. - 600 Two: 300 - 800 Two: 500 - 1000 Two: 6 STR. - 350 Two: 2 STR. - 600 Two: 300 - 800 Two: 500 - 1000

STUD HOLE SIZE1/4 3/8 1/2 5/8

D.81 .81 1.50 1.69 1.75 1.66 1.66 3.00 3.22 3.03 3.03

L1.47 1.47 2.56 2.88 3.20 3.38 3.50 4.50 4.69 4.75 4.75

DIMENSIONS ** N W E.44 .44 .50 .88 .63 .88 .88 .63 .63 .63 .63 1.13 1.25 1.66 1.94 2.41 3.19 3.52 2.31 2.41 3.19 3.19 1.75 1.75 1.75 1.75

T.19 .19 .25 .25 .44 .50 .50 .31 .44 .50 .50

** H.79 .79 1.20 1.25 1.58 1.94 1.94 1.38 1.56 1.94 1.94

RECOMMENDED TIGHTENING TORQUE in-lb50 50 275 275 375 375 375 275 375 375 375

1/2

* "N" indicates NEMA standard stud holes. Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. ** Maximum dimension.

BURNDYMechanicalTYPES K3A-U, KK3A-UUNIVERSAL TERMINALA-26

(Three Conductor) For Aluminum and Copper ConductorsDual-rated three-conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance.

Fig. 1

Fig. 2

AL9CU

Fig. 3

CATALOG NUMBER*K3A2U-2* K3A25U-2* K3A26U-2N K3A27U-2N K3A29U-2N K3A31U-2N K3A36U-2N KK3A36U-2N KK3A40U-2N KK3A44U-2N

FIG. NO.1 1 3 3 3 3 3 2 2 2

WIRE RANGE ALUMINUM OR COPPERThree: 14 STR. - 2 STR. Three: 14 STR. - 1/0 STR. Three: 14 STR. - 2/0 STR. Three: 6 STR. - 3/0 STR. Three: 6 STR. - 250 Three: 6 STR. - 350 Three: 2 STR. - 600 Three: 2 STR. - 600 Three: 300 - 800 Three: 500 - 1000

K11/32 7/16

STUD HOLE SIZE5/16 3/8

D1.63 2.09 3.06 3.00 3.00 3.00 3.22 3.00 3.03 3.34

L2.19 2.91 3.75 3.88 4.00 4.31 4.69 5.63 5.69 6.19

DIMENSIONS N W E.34 .34 .63 .63 .63 .63 .63 .56 .63 .63 1.59 1.94 1.95 2.81 2.81 3.00 3.63 4.22 4.81 4.75 .88 1.00

T.19 .25 .19 .31 .31 .31 .44 .44 .50 .56

H.62 .88 1.79 1.12 1.19 1.38 1.56 1.69 1.94 1.88

RECOMMENDED TIGHTENING TORQUE in-lb50

275

9/16

1/2

1.75

375

* Slotted screw. ** N indicates NEMA standard stud holes. Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N items See note page A-2

BURNDYMechanicalTYPES K3A-U, KK3A-U(Continued)A-27

AL9CU

Fig. 1

Fig. 2

Fig. 3

Fig. 4

CATALOG NUMBER**K3A2U-4* K3A25U-4* K3A27U-4N K3A29U-4N K3A31U-4N K3A36U-4N K3A40U-4N KK3A36U-4N KK3A40U-4N KK3A44U-4N

FIG. NO.3 3 3 3 3 3 3 4 4 4

WIRE RANGE ALUMINUM OR COPPERThree: 14 STR. - 2 STR. Three: 14 STR. - 1/0 STR. Three: 6 STR. - 3/0 STR. Three: 6 STR. - 250 Three: 6 STR. - 350 Three: 2 STR. - 600 Three: 300 - 800 Three: 2 STR. - 600 Three: 350 - 800 Three: 500 - 1000

K11/32 7/16

STUD HOLE SIZE5/16 3/8

D1.63 2.09 3.00 3.00 3.00 3.22 3.03 3.00 3.34 3.34

L2.19 2.91 3.88 4.00 4.31 4.69 4.75 5.63 6.19 6.19

DIMENSIONS N W E.34 .34 1.59 1.94 2.81 2.81 3.00 3.63 4.81 4.22 5.34 4.75 .88 1.00

T.19 .25 .31 .31 .31 .44 .50 .44 .56 .56

H.62 .88 1.12 1.19 1.38 1.56 1.94 1.69 1.88 1.88

RECOMMENDED TIGHTENING TORQUE in-lb50 275

9/16

1/2

.63

1.75

375 275 375

* Slotted screw ** N indicates NEMA standard stud holes. Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N items See note page A-2

BURNDYMechanicalTYPES K4A-U, KK4A-UUNIVERSAL TERMINALA-28

(Four Conductor) For Aluminum and Copper ConductorsThese dual-rated four conductor lugs are constructed from high strength aluminum alloy and electro tin-plated to provide low contact resistance.

Fig. 1

Fig. 2

AL9CU

CATALOG NUMBER*K4A29U-4N K4A31U-4N KK4A36U-4N KK4A40U-4N

FIG. NO.1 1 2 2

WIRE RANGE ALUMINUM OR COPPERFour: 6 STR. - 250 Four: 6 STR. - 350 Four: 2 STR. - 600 Four: 300 - 800

STUD HOLE SIZE1/2

D3 3 3.34 3

L4 4.31 5.63 6.19

DIMENSIONS N W E.63 3.69 5.04 5 6 1.75

T.31 .31 .44 .56

H1.19 1.38 1.69 1.88

RECOMMENDED TIGHTENING TORQUE in-lb275 375

* N indicates NEMA standard stud holes. All 4N items See note page A-2

TYPES K11A-U, K21A-U, K22A-UUNIVERSAL TERMINAL For Aluminum and Copper ConductorsDual-rated panelboard lugs are constructed from high strength extruded aluminum alloy and electro tin-plated to provide low contact resistance.

Fig. 2 Fig. 1

Fig. 3

Fig. 4

Fig. 5

AL9CU

CATALOG NUMBER*K11A30U* K11A34U-2 K11A36U-2 K21A36U-2 K22A36U-2 K11A39U-2 K22A39U-2

FIG. NO.1 2 3 4 5 3 5

WIRE RANGE ALUMINUM OR COPPERTwo: 6 STR. - 300 Two: 4/0 STR. - 500 Two: 2 STR. - 600 Three: 2 STR. - 600 Four: 2 STR. - 600 Two: 1/0 STR. - 750 Four: 1/0 STR. - 750

STUD HOLE SIZE5/16 1/4

D.94

L3.00 2.91

DIMENSIONS N W E.47 .25 1.00 1.44 1.50 2.50 2.50 1.69 3.06 .69

T.31 .63

H2.00 2.38

RECOMMENDED TIGHTENING TORQUE in-lb275

3/8

2.31

4.91

.38

1.38

.75

3.00

375

* Not CSA Listed. Listed torque values are for maximum conductor sizes accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes.

BURNDYMechanicalTYPE KAU-KITTRANSFORMER LUG KITA-29 These dual-rated lugs are constructed from high strength aluminum alloy and electro tinplated to provide low contact resistance. Lugs and mounting hardware packaged together in these kits.

Features and Benefits UL listed AL9CU dual rated set screw terminals and CSA certified. Ensure the transformer feeders and taps are terminated properly. Plated steel cap screws and hex nuts with captive conical washers or individual Belleville washers. Terminal to bus connections are made using proper hardware resulting in true torque to pressure performance. Compensates for dissimilar metal expansion and contraction.

Hardware packed in plastic bag. No lost hardware prior to installation. Larger 800 kcmil lugs in KIT3 and KIT4. Accommodates common 750 kcmil tap conductors in larger transformers.

TERMINALS CATALOG TRANSFORMER CATALOG NUMBER KVA RATING QTY. NUMBERKAU-KIT1 KAU-KIT2 KAU-KIT3 KAU-KIT4 15 - 37.5 15 - 45 50 - 75 75 - 112.5 100 - 167 150 - 300 400 - 500 1 3 1 3 1 3 3 8 4 12 6 7 15 KA2U KA29U KA29U K2A31U K2A40U K2A40U

WIRE RANGE ALUMINUM OR COPPER#14 - 2 #6 - 250 #6 - 250 #6 - 350 300 - 800 300 - 800

QTY.8 8 8 5 6 7 4

BOLT SIZE1/4-20 3/4 HH

HARDWARE QTY. NUT8 16 11 11 1/4 1/4 20 HN 20 HN

QTY. 22 11 22 11

WASHERCaptive to Nut Captive to Nut 1/2 FW 1/2 Belleville 1/2 FW 1/2 Belleville

1/4-20 3/4 HH 1/4-20 2 HH 1/2-13 3 HH 1/2-13 2-1/2 HH 1/2-13 2 1/2-13 2-1/2

1/2-13 HN 1/2-13 HN

BURNDYMechanicalTYPE AMSA-30

DUAL RATED SPLICER/REDUCER For Copper and Aluminum CableAll splicer/reducers are dual rated for use with aluminum and copper conductors and are constructed from high strength, tin plated aluminum. PENTROX oxide inhibiting joint compounds are recommended for all aluminum applications.

Features and Benefits All connectors are tin-plated. Provide low contact resistance and prevents galvanic corrosion. Connectors feature rounded bottoms. Facilitates taping. Solid center barrier. Prevents contact of dissimilar metals. Large screw diameters. Ensures greater surface contact with wires for maximum pullout force. Large cable ranges. Each splice is also an effective reducing connector.

CATALOG NUMBERAMS-2* AMS-0* AMS-4/0 AMS-250 AMS-350 AMS-500 AMS-750 AMS-1000

WIRE RANGE MAX. MIN.2 1/0 4/0 250 350 500 750 1000 14 8 6 6 6 3/0 250 500

L1-19/32 1-29/32 2-5/16 4-3/32 4-11/32 4-25/32 6-1/16 8-11/16

W9/16 3/4 1 1 1 1-1/4 1-7/16 1-21/32

H19/16 3/4 1-3/32 1-3/32 1-3/32 1-3/8 1-5/8 1-7/8

H2 MAX..79 .86 1.28 1.29 1.30 1.48 1.98 2.34

NO. OF SCREWS2 2 2 4 4 4 4 6

SCREW DIA.3/8 7/16 9/16 5/8 11/16 13/16 15/16 1-1/8

HEX SIZES S 5/16 5/16 5/16 3/8 1/2 9/16

* Slotted Screws. H2 measured with maximum conductors, reference only. Complies with NFPA 78-86.

BURNDYMechanicalTYPE AGSKITABOVE GRADE SPLICE KITS For all Aluminum or Copper/Aluminum CombinationsType AGS Above Grade Splice Kit consists of a standard AMS splice/reducer and a heavy wall heat-shrink sleeve. The AMS Splice is dual rated for use with aluminum and copper conductors and are constructed from high strength, tin plated aluminum that provides low contact resistance and reduces the effects of galvanic corrosion. Connector is installed with common installation tools. The heavy wall heat shrink sleeve is lined with adhesive material, providing a positive seal against moisture egress. Heat shrink sleeve is installed with standard propane torch, or electric heat gun. A-31

Fig. 1

Fig. 2

Catalog Number AGSKIT2 AGSKIT250

Figure Number 1 2

Wire Range Maximum Minimum 2 8 250 1

TYPE UGSKITWATERTIGHT/UNDERGROUND SPLICE KITS For all Aluminum or Copper/Aluminum CombinationsType UGS Watertight Underground Splice Kit consists of a standard AMS splice/reducer and two heavy wall heat-shrink sleeves. The AMS Splice is dual rated for use with aluminum and copper conductors and are constructed from high strength, tin plated aluminum that provides low contact resistance and reduces the effects of galvanic corrosion. Connector installed with common installation tools. Both heavy wall heat shrink sleeves are lined with adhesive material, providing a watertight splice that can withstand abrasions that may occur during direct burial applications. Heat shrink sleeve installed with standard propane torch, or electric heat gun.

Fig. 1

Fig. 2

Catalog Number UGSKIT2* UGSKIT250*

Figure Number 1 2

Wire Range Maximum Minimum 2 8 250 1

*UL486D Listed for Direct Burial

BURNDYMechanicalTYPE UGSKIT8A-32

UF DIRECT BURIAL SPLICE KITType UGS UF Splice Kit consists of a UF splice connector and a heavy wall heat-shrink sleeve. The UF splice connector can accommodate up to four UF conductors and is installed with common installation tools. The heavy wall heat shrink sleeve is lined with an adhesive material, providing a watertight splice that can withstand abrasions that may occur during direct burial applications. Heat shrink sleeve installed with standard propane torch, or electric heat gun.

Catalog Number UGSKIT8**UL486D Listed for Direct Burial

Wire Range Copper 8 AWG 14 AWG

TYPE UGS350ULDBIN-LINE SPLICE/REDUCER For Direct Burial

Features and Benefits EPDM rubber covered 6061-T6 aluminum connector. Dual rated AL9CU for copper or aluminum conductor. UL Listed and CSA Certified for Direct Burial. Broad range taking capability. Low installation cost.

CATALOG NUMBERUGS350ULDB

WIRE RANGE12 AWG - 350 kcmil

LENGTH In. [mm]8.50 [216]

HEIGHT In. [mm]2.81 [71.4]

HEX SIZE5/16

TORQUE (In. Lbs.)350

Dimensions in brackets [ ] are in millimeters.

BURNDYMechanicalTYPE QGFLBARTAP For Copper Cable To FlatHigh copper alloy BARTAP for joining a range of cable to bar or pad. One-wrench installation. A-33

CATALOG NUMBERQGFL1CB1 QGFL1CB1T6 QGFL26B1 QGFL26B1T6 QGFL26B2* QGFL26B2T6* QGFL29B1* QGFL29B1T6* QGFL31B1* QGFL31B1T6* QGFL34B1 QGFL34B1T6 QGFL39B1 QGFL39B1T6 QGFL44B1 QGFL44B1T6 QGFL46B1 QGFL46B1T6 QGFL48B1 QGFL48B1T6

COPPER CONDUCTOR10 SOL. - 1 STR.

B1-1/8 1-1/4 1-1/2

H1-7/8 2-3/8 2-1/8 2-5/8 2-1/2 2-1/8 2-5/8 3-1/8 2-7/8 3-1/4 3-1/8 3-5/8 3-1/4 3-5/8 3-3/8 4-1/8 4 4-1/2 5-1/4 5-1/4

J3/8

T (MAX.)1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4

W1

8 SOL. - 2/0 STR.

1-1/8

6 STR. - 250 1-5/8 2 SOL. - 350 1-3/4 1/0 SOL. - 500 2 350 - 750 750 - 1000 1000 - 1500 1500 - 2000 2-1/4

1-3/8 1-5/8

1/2

1-3/4

2-1/8 2-1/2 3

* Can be installed side by side or in-line on NEMA drilled bar.

BURNDYMechanicalTYPE FCBA-34

TRANSFORMER TAP ADAPTER For Copper and AluminumSilver brazed 101% conductivity copper transformer tap adapter designed to accommodate from 1 to 6 NEMA drilled copper or aluminum terminal taps from a single secondary transformer outlet. Tin-plated. Order mounting hardware & tap terminals separately.

Fig. 1

FIG. NO.1 2 1 2 1 2 4

CATALOG NUMBERFCB63-4N FCB63-6N FCB64-4N FCB64-6N FCB65-4N FCB65-6N FCB63-2NP300 FCB64-44NP50

A DIA..50 .50 .75 .75 1.00 1.00 .50 .75

H REF.5.25 5.25 5.75 5.75 7.00 7.00 5.00 9.00

L3.75 5.50 4.00 5.75 4.25 6.00 3.50 5.00

P2.25 2.25 2.75 2.75 4.00 4.00 3.00 5.00

NOTE: All pads are NEMA drilled.

Fig. 2

BURNDYMechanicalTYPE KPU-ACPOLYTAP Insulated Gutter Tap for All Copper and Aluminum CombinationsWide range-taking tin-plated aluminum parallel clamp and insulating cover assembly for industrial and multiple story structure applications. Only six connectors cover the entire 14 Sol.-750 kcmil range. Covers having flexible fingers that conform to conductor, fully insulating the connection. UL486B listed for 600 volts maximum 90 C service. Cover and connector are packaged together. No taping required. 600 Volt Max. 90 C A-35

CATALOG NUMBERKPU29A26AC KPU29A29AC KPU34A26AC KPU34A34AC KPU39A26AC KPU39A39AC

CONDUCTOR COPPER OR ALUMINUM RUN TAP1/0 STR. - 250 1/0 STR. - 250 4/0 STR. - 500 4/0 STR. - 500 500 - 750 500 - 750 14 SOL. - 2/0 STR. 6 STR. - 250 14 SOL. - 2/0 STR. 6 STR. - 500 14 SOL. - 2/0 STR. 1/0 STR. - 750

W4 4-11/32 4-13/16

H2-11/16 1-7/8 3-1/4

L3-1/8 3-1/2

RECOMMENDED TIGHTENING TORQUE in-lb375 450 600

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller combinations. See note page A-2.

TYPE UCU-ACRISER TAPParallel-groove riser tap and insulation cover for copper and aluminum. Wide range-taking assembly for apartment house and light industrial applications. Cover and connector are packaged together. Covers having insulating fingers that conform to conductors, fully insulating the connection. UL486B Listed for 600 volts max. 90 C service.

600 VOLT MAX. 90 C MAX.

CATALOG NUMBERUCU28AC

CONDUCTOR RUN TAP2 STR. - 4/0 STR. 10 SOL. - 2 STR.

W2-1/4

H1-13/16

L2-5/8

RECOMMENDED TIGHTENING TORQUE in-lb120

Listed torque values are for maximum conductor combinations accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller combinations.

BURNDYMechanicalTYPE BIPCINSUL-TAPA-36

UL Listed 90 C, *600 VoltThe INSUL-TAP, TYPE BIPC, Burndy Insulation Piercing Connector is ideally suited for splicing and tapping aluminum and copper conductor wire sizes: #10 AWG to 500 kcmil. The BIPC's unique insulation piercing design allows for use on hot-line applications, eliminating the need for taping.

Features and Benefits Insulation piercing capability. Eliminates the need for conductor insulation stripping. UL486B listed, AL9CU rated. For copper and aluminum conductor combinations up to 90 *600 Volt applications. Insulation piercing design. For use on hot-line applications. Eliminates the need for taping. Easy snap-out tabs. Eases installation, protects connection from dirt and debris. Simple bolt-on connection. Eases installation.

Fig. 1

Fig. 2MAX. VOLTAGE RATING600V 300V 300V 300V 300V 600V

CATALOG NUMBERBIPC1/0-2 BIPC4/0-6 BIPC4/0-1/0 BIPC350-4/0 BIPC350-350 BIPC500-4/0

CONDUCTOR RANGE RUN TAP1/0 - 8 AWG [50 - 6 mm2] 4/0 - 1/0 AWG [95 - 50 mm2] 4/0 - 1/0 AWG [95 - 50 mm2] 350 - 4/0 AWG [185 - 95 mm2] 350 - 4/0 AWG [185 - 95 mm2] 500 - 350 kcmil [240 - 185 mm2] 2 - 8 AWG [35 - 6 mm2] 1/0 - 6 AWG [50 - 16 mm2] 4/0 - 1/0 AWG [95 - 50 mm2] 4/0 - 10 AWG [95 - 6 mm2] 350 - 4/0 AWG [185 - 95 mm2] 4/0 - 4 AWG [95 - 25 mm2]

BOLT SIZE5/16-18 5/16-18 5/16-18 3/8-16 3/8-16 3/8-16

SOCKET FIG. SIZE NO.1/2 1/2 1/2 9/16 9/16 9/16 1 2 2 1 2 1

DIMENSIONS H L W2.00 [51] 2.50 [64] 2.50 [64] 3.00 [76] 3.00 [76] 3.25 [83] 1.53 [39] 2.12 [54] 2.12 [2.12] 1.59 [40] 2.62 [67] 1.59 [40] 2.56 [65] 2.00 [51] 2.06 [52] 2.50 [64] 2.75 [70] 2.62 [67]

RECOMMENDED TORQUE (N,m)180 in. lbs. [20.3 N.m] 250 in. lbs. [28.3 N.m] 250 in. lbs. [28.3 N.m] 375 in. lbs. [42.4 N.m] 300 in. lbs. [33.9 N.m] 400 in. lbs. [45.2 N.m]

BURNDYMechanicalSPEC-BLOK POWER DISTRIBUTION CONNECTORSUnique, modular, made-to-order, powerdistribution assemblies accommodate any number of supply and load conductors in any number of poles. Capacity matches the conductors accommodated and SPEC-BLOK assures uniform loading. Burndy will design, quote, assemble and ship SPEC-BLOK especially constructed to suit your particular requirements within 48 hours upon request. Adjacent poles are separated by easy-tohandle, wrap-around insulating covers which eliminate taping and reduce heat build-up by allowing air to flow freely around connectors. SPEC-BLOK is UL Listed for copper or aluminum conductors for 600 volts. (AL9CU) Assemblies are mounted on platforms suitable for easy installation in wireway or junction box.

A-37

Features and Benefits Accommodate unlimited conductors. Fits wide range of applications. Eliminates need for non-UL-listed improvisation. Connector elements tin-plated. Provides high reliability, low-resistance connections. User friendly, space-saving design. Easy to install. Saves labor. 94-VO rated insulation folds into place insulating the components. Saves time and material. Allows easy installation. Connector caps removable for easy cable lay-in. Saves labor. Makes installation easier. Allows installation or straight-through conductors. Eases retrofit. Belleville washers built-in on pressure screw assemblies, except in assemblies installed with a 5/32" Allen wrench. Provides high-integrity connections. Conductors can be cut or fed straight through. Straight through installation ideal for riser applications.

Contact Burndy or Technical Services, 1-800-451-4956 or Burndy Customer Service, 1-800-346-4175

BURNDYMechanicalSPEC-BLOKA-38

Features and Benefits The SPEC-BLOK system includes 12 connector elements A wide variety of conductor sizes can be accommodated Each element can be bolted together in parallel Provides an efficient flow of current from one element to another AL9CU rated for Copper or Aluminum conductors Dual-rated system, with UL486Bs highest temperature rating 2 Wire (series), 4 (parallel), and Multi-Tap versions available Nearly any conductor combination can be terminated Tin-plated Aluminum Alloy Construction High-strength, corrosion-resistant connector elements All SPEC-BLOKs are custom made for nearly any Power Distribution system requirement Time savings pre-assembled in our factory for immediate installation! D T

E

W

SPEC-BLOK CONNECTORS

C

S

B

R

A

Q

U

P

CATALOG DESIGNATION (MAXIMUM CONDUCTOR)

NUMBER OF CONDUCTORS ACCOMMODATED

4 Conductor A

2 Conductor Q

4 Conductor

2 Conductor

DIMENSIONS ALLEN WRENCH Second SIZE Conductor Length Without Insulator (if Height On First Width required) Max 4 2 Conductors May Be Conductors Conductor Conductor MUST Be 1/0-2/0 #12-2/02-9/16 1-1/2 2-1./8 7/8 5/32"

AL or CU WIRE RANGE UNDER EACH CAP

(2/0) B (250) C (350) D (500) E (750) W 600-750 3/0-7504-7/8 2-1/4 7-1/4 2-5/8

R

3/0-250

#6-2503-1/8 1-11/16 4-1/4 1-3/8 1/4" 3-5/16 1-13/16 4-5/8 1-1/2

S

1 to 4 (0, 1 or 2 per cap)

1 or 2 per cap

250-350

#6-350

T

400-500

#6-5004-1/16 2 5-5/8 1-3/4 3/8"

Catalog Designation Number of Conductors (Maximum Conductor) Accommodated P (1/0) 1 to 8 (0, 1 or 2 under each screw) U (1/0 & 500) 2 to 9 (0, 1 or 2 under each screw plus one large conductor)** This range may be expanded to include #8 provided two conductors are being installed in that particular element.

Large Groove __

Small Grooves** 6-1/0

Height On Maximum Conductors 3 1/2

Width 2

Length Without Insulator

Allen Wrench Size

1 3/4 3/0-500 6-1/0 4 1/8 2

5/32"

BURNDYMechanicalSPEC-BLOKMOUNTING PLATFORMSA-39 SPEC-BLOK Mounting Platforms are rigid steel construction with a black finish. They can be supplied for junction box mounting or wireway construction allowing trough conductors to pass underneath the assemblies.

(CPB-)CATALOG NUMBERCPB6 CPB8 CPB10 CPB12 CPB16-5/8 CPB21-1/4

(CPT-)L (Nominal)6 8 10 12 16-5/8 21-1/4

L (Overall)7-3/4 9-3/4 11-3/4 13-3/4 18-3/8 23

W (Overall)2-1/2 2-1/2 2-1/2 3-1/2 3-1/2 3-1/2

CATALOG NUMBERCPT6 CPT8 CPT10 CPT12 CPT16

L5-7/8 7-7/8 9-7/8 11-7/8 15-7/8

W2-1/2 3-1/2 3-1/2 3-1/2 3-1/2

H2-1/4 3 3-1/2 4 4

SPEC-BLOK catalog numbers describe exactly how the distribution block is assembled:5DR-NDST-GQP-12 (assembly pictured) 5 DR Total number of poles in the completed assembly One 'D' unit and one 'R' unit, bolted in parallel, forming each phase pole (3 phase poles)

N

Denotes the beginning of the neutral pole (where required) DST One 'D' unit, one 'S' unit, and on 'T' unit, bolted in parallel, forming the neutral pole G QP Denotes the beginning of the ground pole description (where required) One 'Q' unit and on 'P' unit, bolted in parallel, forming the ground pole. Size (inches) of the wireway or trough that is needed to enclose the assembly. If a junction box enclosure is used, no number is used to denote the size of the enclosure.

12

SPEC-BLOK IS A SYSTEM THAT CAN SOLVE MOST POWER DISTRIBUTION APPLICATIONS!

BURNDYMechanicalQUESTIONNAIREA-40

FOR SPEC-BLOK OR ELECTRO-RAIL APPLICATIONSWhat is the total capacity of the system?_____________amps How many poles in the system (3-wire, 4-wire, single phase, etc.)?_____________poles Are neutral conductors (when required) different sizes (AWG/KCMil) than the phase conductors? _________the same size __________different size Yes No Are any conductors continuous? Yes No

If yes, which ones?____________________________________ ___________________________________________________ What kind of enclosure is connection assembly being mounted into and what are inside space dimensions? Trough size _________________________________________ Box, panel, cabinet, other size___________________________ When is a quotation required? Date:______________________ When is the material required? Date:_____________________ CONDUCTOR TYPE (Cu/Al) Is there a preference for a particular Burndy distributor? Yes No If yes, give name, location & telephone Number: Name:______________________________________________

Is a ground connection required?

What are the quantities, sizes (AWG/kcmil) and material (Al/Cu) of the incoming line conductors and outgoing load conductors?

QUANTITY LINE PER PHASE LOAD

SIZE

Address:____________________________________________ LINE PER NEUTRAL LOAD LINE PER GROUND LOAD __________________________________________________ Phone #:____________________________________________

BURNDYMechanical3 WIRE BUS ASSEMBLY FOR TROUGH(INSULATING COVERS AND MOUNTING BASE INCLUDED)Bus Assemblies consist of tin plated aluminum bus mounted to an insulating platform. Each phase is separated with 94VO 600 volt wrap-around adhesive insulations. The entire assembly is mounted on a trough type base.

A-41

CATALOG NUMBER1300A-8-3-10 1300A-12-3-10 1300A18-3-10 1300A-24-3-10 1300A-30-3-10 1350A-8-3-12 1350A-12-3-12 1350A-18-3-12 1350A-24-3-12 1350A-30-3-12 1500A-12-3-10 1500A-18-3-10 1500A-24-3-10 1500A-30-3-10 1500A-12-3-12 1500A-18-3-12 1500A-24-3-12 1500A-30-3-12

AMP RATING PER BUS1300 1300 1300 1300 1300 1350 1350 1350 1350 1350 1500 1500 1500 1500 1500 1500 1500 1500

DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 8 12 18 24 30 12 18 24 30 12 18 24 30 12 16 22 28 34 12 16 22 28 34 16 22 28 34 16 22 28 34

WIDTH10 10 10 10 10 12 12 12 12 12 10 10 10 10 12 12 12 12

HEIGHT4.75 4.75 4.75 4.75 4.75 5.25 5.25 5.25 5.25 5.25 4.75 4.75 4.75 4.75 5.25 5.25 5.25 5.25

WEIGHT8 lbs. 11 lbs. 15 lbs. 22 lbs. 26 lbs. 9 lbs. 12 lbs. 16 lbs. 23 lbs. 27 lbs. 15 lbs. 18 lbs. 27 lbs. 30 lbs. 16 lbs. 19 lbs. 28 lbs. 31 lbs.

PCS. PER CTN.1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

BURNDYMechanical4 WIRE BUS ASSEMBLY FOR TROUGH(INSULATING COVERS AND MOUNTING BASE INCLUDED)

A-42

CATALOG NUMBER1350A-8-4-12 1350A-12-4-10 1350A-18-4-12 1350A-24-4-12 1350A-30-4-12 1500A-12-4-12 1500A-18-4-12 1500A-24-4-12 1500A-30-4-12

AMP RATING PER BUS1350 1350 1350 1350 1350 1500 1500 1500 1500

DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 12 18 24 30 12 16 22 28 34 16 22 28 34

WIDTH12 12 12 12 12 12 12 12 12

HEIGHT5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25

WEIGHT10 lbs. 13 lbs. 17 lbs. 26 lbs. 30 lbs. 18 lbs. 21 lbs. 30 lbs. 34 lbs.

PCS. PER CTN.1 1 1 1 1 1 1 1 1

BURNDYMechanicalWIRE BUS ASSEMBLY FOR JUNCTION BOXES(INSULATING COVERS AND MOUNTING BASE INCLUDED)

A-43

3 WIRE BUS ASSEMBLY FOR JUNCTION BOXES (INSULATING COVERS AND MOUNTING BASE INCLUDED)CATALOG NUMBER1350A-8-3-B 1350A-12-3-B 1350A-18-3-B 1350A-24-3-B 1350A-30-3-B 1500A-12-3-B 1500A-18-3-B 1500A-24-3-B 1500A-30-3-B

AMP RATING PER BUS1350 1350 1350 1350 1350 1500 1500 1500 1500

DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 12 18 24 30 12 16 22 28 34 16 22 28 34

WIDTH12 12 12 12 12 12 12 12 12

HEIGHT2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75

WEIGHT9 lbs. 12 lbs. 16 lbs. 23 lbs. 27 lbs. 15 lbs. 18 lbs. 27 lbs. 30 lbs.

PCS. PER CTN.1 1 1 1 1 1 1 1 1

4 WIRE BUS ASSEMBLY FOR JUNCTION BOXES (INSULATING COVERS AND MOUNTING BASE INCLUDED)CATALOG NUMBER1350A-8-4-B 1350A-12-4-B 1350A-18-4-B 1350A-24-4-B 1350A-30-4-B 1500A-12-4-B 1500A-18-4-B 1500A-24-4-B 1500A-30-4-B

AMP RATING PER BUS1350 1350 1350 1350 1350 1500 1500 1500 1500

DIMENSIONS LENGTH BUS INSULATION8 12 18 24 30 12 18 24 30 12 16 22 28 34 16 22 28 34

WIDTH16 16 16 16 16 16 16 16 16

HEIGHT2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75

WEIGHT10 lbs. 13 lbs. 17 lbs. 26 lbs. 30 lbs. 18 lbs. 21 lbs. 30 lbs. 34 lbs.

PCS. PER CTN.1 1 1 1 1 1 1 1 1

BURNDYMechanicalVERSI-POLEA-44

POWER DISTRIBUTION BLOCKSVERSI-POLE Power Distribution Blocks are designed to provide modular solutions to power distribution applications. Each connector element is made from a high conductivity aluminum alloy which is insulated with a high strength polymer housing. One, two, and three pole versions available. "Add" a pole (snap-together) blocks are also available for wire sizes up to 500 kcmil. For use with Cu or Al. 600 V, AL9CU rated.

Features and Benefits "Add" a pole feature available. Provides capability to create as many poles as required. Up to 30 tap conductors accommodated. Ideal for current distribution to multiple locations. Single or dual run connections. Allows user to minimize the number of connectors needed to do the job. Suitable for use with aluminum or copper conductors. Provides maximum versatility. 600 V, AL9CU rated.* Meets or exceeds industry standard requirements. Dead-front covers available Provides user protection one cover per pole.* BDB-430-500-1 not UL recognized or CSA certified

VERSI-POLE SNAPTOGETHER BLOCKSCATALOG NUMBERBDA-112-350

CONNECTOR RUN TAP

RUN WIRE RANGE AL9CU350 kcmil - 6

TAP WIRE RANGE AL9CU4 - 14

AMPERE RATING PER POLE350

NUMBER OF POLESADDER

BDA-16-350

350 kcmil - 6

2/0 - 14

350

ADDER

BDA-16-500

500 kcmil - 4

2/0 - 4

430

ADDER

BDA-26-350

350 kcmil - 6

2/0 - 14

700

ADDER

BDA-212-500

500 kcmil - 4

4 - 14

860

ADDER

BDA-26-500

500 kcmil - 4

2/0 - 14

860

ADDER

BDA-24-500

500 kcmil - 4

4/0 - 6

860

ADDER

BDA-11-500

500 kcmil - 4

500 kcmil - 4

430

ADDER

BDA-22-350

350 kcmil - 6

350 kcmil - 6

700

ADDER

BDA-22-500NOTES: 1. Order Optional BDB COVER1 per pole if desired. 2. Snap-together blocks can also be assembled to 1, 2, 3 pole blocks to create multi-pole distribution blocks.

500 kcmil - 4

500 kcmil - 4

860

ADDER

BURNDYMechanicalVERSI-POLEVERSI-POLE 1, 2, 3 POLE DISTRIBUTION BLOCKSA-45

CATALOG NUMBERBDB-16-2/0-1 BDB-16-2/0-2 BDB-16-2/0-3 BDB-26-2/0-1 BDB-26-2/0-2 BDB-26-2/0-3 BDB-112-350-1 BDB-112-350-2 BDB-112-350-3 BDB-16-350-1 BDB-16-350-2 BDB-16-350-3 BDB-14-500-1 BDB-14-500-2 BDB-14-500-3 BDB-16-500-1 BDB-16-500-2 BDB-16-500-3 BDB-162-500-1 BDB-162-500-2 BDB-162-500-3 BDB-26-350-1 BDB-26-350-2 BDB-26-350-3 BDB-212-500-1 BDB-212-500-2 BDB-212-500-3 BDB-26-500-1 BDB-26-500-2 BDB-26-500-3 BDB-24-500-1 BDB-24-500-2 BDB-24-500-3

CONNECTOR RUN TAP

RUN WIRE RANGE AL9CU2/0 - 12

TAP WIRE RANGE AL9CU4 - 14

AMPERE RATING PER POLE195

OPTIONAL NUMBER OF COVER ORDER POLES 1 PER POLE1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 BDBCOVER2

2/0 - 14

2 - 14

390

BDBCOVER2

350 kcmil - 6

4 - 14

350

BDBCOVER1

350 kcmil - 6

2/0 - 14

350

BDBCOVER1

500 kcmil - 4

2/0 - 14

430

BDBCOVER2

500 kcmil - 4

2/0 - 14

430

BDBCOVER1

500 kcmil - 4

2 - 14

430

BDBCOVER2

350 kcmil - 6

2/0 - 14

700

BDBCOVER1

500 kcmil - 4

4 - 14

860

BDBCOVER1

500 kcmil - 4

2/0 - 14

860

BDBCOVER1

500 kcmil - 4

4/0 - 6

860

BDBCOVER1

BURNDYMechanicalVERSI-POLEA-46

VERSI-POLE 1, 2, 3 SPLICE/REDUCER BLOCKSCATALOG NUMBERBDB-11-2/0-1 BDB-11-2/0-2 BDB-11-2/0-3 BDB-11-350-1 BDB-11-350-2 BDB-11-350-3 BDB-11-500-1 BDB-11-500-2 BDB-11-500-3 BDB-22-2/0-1 BDB-22-2/0-2 BDB-22-2/0-3 BDB-22-350-1 BDB-22-350-2 BDB-22-350-3 BDB-22-500-1 BDB-22-500-2 BDB-22-500-3

CONNECTOR RUN TAP

RUN WIRE RANGE AL9CU2/0 - 14

TAP WIRE RANGE AL9CU2/0 - 14

AMPERE RATING PER POLE195

OPTIONAL NUMBER OF COVER ORDER POLES 1 PER POLE1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 BDBCOVER2

350 kcmil - 6

350 kcmil - 6

350

BDBCOVER2

500 kcmil - 6

500 kcmil - 6

430

BDBCOVER1

2/0 - 14

2/0 - 14

390

BDBCOVER2

350 kcmil - 6

350 kcmil - 6

700

BDBCOVER1

500 kcmil - 4

500 kcmil - 4

860

BDBCOVER1

SNAP TOGETHER SPLICER/REDUCER BLOCKSCATALOG NUMBERBDC-14-2/0-1

CONNECTOR RUN TAP

RUN WIRE RANGE AL9CU2/0 - 14

TAP WIRE RANGE AL9CU4 - 14

AMPERE RATING PER POLE195

OPTIONAL NUMBER OF COVER ORDER POLES 1 PER POLE1 BDBCOVER3

BDA-14-2/0-1

2/0 - 14

4 - 14

195

ADDER

BDBCOVER3

BDC-11-2/0-1

2/0 - 14

2/0 - 14

195

1

BDBCOVER3

BDA-11-2/0-1

2/0 - 14

2/0 - 14

195

ADDER

BDBCOVER3

BURNDYMechanicalVERSI-POLE(Continued) VERSI-POLE 1, 2, 3 SPLICE/REDUCER BLOCKSThese tables and illustrations refer to VERSIPOLE Power Distribution Blocks listed on pages A-48 through A-50. A-47

THE FIGURE TO THE LOWER RIGHT IS APPLICABLE TO THE FOLLOWING:Catalog Number BDA-11-500 BDA-112-350 BDA-16-350 BDA-16-500 BDA-212-500 BDA-22-350 BDA-22-500 BDA-24-500 BDA-26-350 BDA-26-500 BDB-11-500-1 BDB-11-500-2 BDB-11-500-3 BDB-112-350-1 BDB-112-350-2 BDB-112-350-3 BDB-16-350-1 BDB-16-350-2 BDB-16-350-3 BDB-16-500-1 BDB-16-500-2 Number of Poles 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 2 3 1 2 3 1 2 3 1 2 Catalog Number BDB-16-500-3 BDB-212-500-1 BDB-212-500-2 BDB-212-500-3 BDB-22-350-1 BDB-22-350-2 BDB-22-350-3 BDB-22-500-1 BDB-22-500-2 BDB-22-500-3 BDB-24-500-1 BDB-24-500-2 BDB-24-500-3 BDB-26-350-1 BDB-26-350-2 BDB-26-350-3 BDB-26-500-1 BDB-26-500-2 BDB-26-500-3 BDB-430-500-1 Number of Poles 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1

NO. OF POLESAdder 1 2 3 N

DIMENSIONS A INCHES2.50 2.81 5.31 7.81 (2.50 X N) + .31

Example for 10 poles: A = (2.50 X 10) + .31 = 25

BURNDYMechanicalVERSI-POLE(Continued)A-48

VERSI-POLE 1, 2, 3 SPLICE/REDUCER BLOCKSThese tables and illustrations refer to VERSIPOLE Power Distribution Blocks listed on pages A-48 through A-50. THE FIGURE TO THE RIGHT IS APPLICABLE TO THE FOLLOWING:Catalog Number BDB-11-2/0-1 BDB-11-2/0-2 BDB-11-2/0-3 BDB-11-350-1 BDB-11-350-2 BDB-11-350-3 BDB-14-500-1 BDB-14-500-2 BDB-14-500-3 BDB-16-2/0-1 BDB-16-2/0-2 BDB-16-2/0-3 BDB-162-500-1 BDB-162-500-2 BDB-162-500-3 BDB-22-2/0-1 BDB-22-2/0-2 BDB-22-2/0-3 BDB-26-2/0-1 BDB-26-2/0-2 BDB-26-2/0-3 Number of Poles 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3

NO. OF POLESAdder 1 2 3 N

DIMENSIONS A INCHES1.64 1.94 3.57 5.20 (1.64 X N) + .30

Example for 10 poles: A = (1.64 X 10) + .30 = 16.20

APPLICABLE VERSI-POLETM ITEMS Catalog Number BDA-14-2/0-1 BDC-14-2/0-1 BDA-11-2/0-1 BDC-11-2/0-1 Number of Poles 1 (adder) 1 1 (adder) 1

NO. OF POLESAdder 1 2 3 N

DIMENSIONS A INCHES.81 1.08 1.89 2.70 (.81 X N) + .27

Example for 10 poles: A = (.81 X 10) + .27 = 8.37

BURNDYMechanicalBURNDY UNITAPCLEAR INSULATED MULTIPLE TAP CONNECTORSTap connections and in-line splice/reductions are made quickly and easily with the UNITAP line of connectors. UL486B Listed. Dual-rated AL9CU for any stranded copper or stranded aluminum applications. 600 Volt, 90 C. A-49

Features and Benefits Clear Plastisol covered AL6061-T6 aluminum body. Saves time, lowers installation costs, eliminates taping. Clear Plastisol. Allows visual confirmation that conductor is properly inserted. Oxide inhibitor pre-installed. Inhibits moisture and contaminants from entering the contact area. Range-taking. Reduces number of connectors carried in inventory.

2 PORT 1 or 2 Sided EntryCatalog NumberBIT4 BITO4 BIT2/0 BITO2/0 BIT250 BITO250 BIT350 BITO350 BIT600 BITO600 BIT750* BITO750** Not UL Listed

# of Ports2 2 2 2 2 2 2 2 2 2 2 2

Wire Range (AWG/kcmil)#14 - #4 #14 - #4 #14 - 2/0 #14 - 2/0 #10 - 250 #10 - 250 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #2 - 750 #2 - 750

L1.16 1.16 1.52 1.52 2.03 2.03 2.22 2.22 2.72 2.72 2.87 2.87

W1.16 1.50 1.40 1.56 2.07 2.64 2.32 3.00 2.38 3.00 2.70 3.38

H1.25 1.25 1.38 1.38 2.13 2.13 2.50 2.50 2.75 2.75 3.00 3.00

Hex Key1/8 1/8 3/16 3/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8

Fig. No.1 2 1 2 1 2 1 2 1 2 1 2

Fig. 1

Fig. 2

IN-LINE SPLICER/REDUCERCatalog NumberBISR2 BISR1/0 BISR250 BISR350 BISR500

Wire Range (AWG/kcmil)#14 - 2 #14 - 1/0 #10 - 250 #10 - 350 #6 - 500

L2.38 2.91 4.01 4.63 5.00

W0.75 0.91 1.19 1.34 1.62

H1.22 1.38 2.10 2.35 2.62

Hex Key5/32 3/16 5/16 5/16 3/8

BURNDYMechanicalBURNDY UNITAPA-50

MULTI-PORT Single-Sided EntryCatalog NumberBIBS4-3 BIBS4-4 BIBS4-5 BIBS4-6 BIBS4-8 BIBS2/0-3 BIBS2/0-4 BIBS2/0-5 BIBS2/0-6 BIBS2/0-8 BIBS2/0-10 BIBS2/0-12 BIBS2/0-14 BIBS250-3 BIBS250-4 BIBS250-5 BIBS250-6 BIBS250-8 BIBS250-10 BIBS250-12 BIBS250-14 BIBS350-3

# of Wire Range Ports (AWG/kcmil)3 4 5 6 8 3 4 5 6 8 10 12 14 3 4 5 6 8 10 12 14 3 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 350

L1.59 2.03 2.47 2.91 3.78 2.19 2.86 3.53 4.20 5.55 6.89 8.24 9.58 2.97 3.91 4.84 5.78 7.66 9.53 11.41 13.29 3.13

W1.25 1.25 1.25 1.25 1.25 1.31 1.31 1.31 1.31 1.31 1.31 1.31 1.31 2.07 2.07 2.07 2..07 2.07 2.07 2.07 2.07 2.32

H1.25 1.25 1.25 1.25 1.25 1.38 1.38 1.38 1.38 1.38 1.38 1.38 1.38 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.50

Hex Key1/8 1/8 1/8 1/8 1/8 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16

Catalog NumberBIBS350-4 BIBS350-5 BIBS350-6 BIBS350-8 BIBS350-10 BIBS350-12 BIBS350-14 BIBS600-3 BIBS600-4 BIBS600-5 BIBS600-6 BIBS600-8 BIBS600-10 BIBS600-12 BIBS600-14 BIBS750-3* BIBS750-4* BIBS750-6* BIBS750-8* BIBS750-10* BIBS750-12* BIBS750-14** Not UL Listed

# of Wire Range Ports (AWG/kcmil)4 5 6 8 10 12 14 3 4 5 6 8 10 12 14 3 4 6 8 10 12 14 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750

L4.04 4.95 5.86 7.68 9.50 11.32 13.14 4.00 5.28 6.56 7.84 10.41 12.97 15.53 18.09 4.25 5.63 8.37 11.13 13.87 16.63 19.37

W2.32 2.32 2.32 2.32 2.32 2.32 2.32 2.38 2.38 2.38 2.38 2.38 2.38 2.38 2.38 2.70 2.70 2.70 2.70 2.70 2.70 2.70

H2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 3.00 3.00 3.00 3.00 3.00 3.00 3.00

Hex Key5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8

BURNDYMechanicalBURNDY UNITAPA-51

MULTI-PORT Double-Sided EntryCatalog NumberBIBD4-2 BIBD4-3 BIBD4-4 BIBD4-5 BIBD4-6 BIBD4-8 BIBD2/0-2 BIBD2/0-3 BIBD2/0-4 BIBD2/0-5 BIBD2/0-6 BIBD2/0-8 BIBD2/0-10 BIBD2/0-12 BIBD2/0-14 BIBD250-2 BIBD250-3 BIBD250-4 BIBD250-5 BIBD250-6 BIBD250-8 BIBD250-10 BIBD250-12 BIBD250-14 BIBD350-2

# of Wire Range Ports (AWG/kcmil)2 3 4 5 6 8 2 3 4 5 6 8 10 12 14 2 3 4 5 6 8 10 12 14 2 #14 - #4 #14 - #4 #14 - #4 #14 - #4 #14 - #4 #14 - #4 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 350

L1.16 1.59 2.03 2.47 2.91 3.78 1.52 2.19 2.86 3.53 4.20 5.55 6.89 8.24 9.58 2.03 2.97 3.91 4.84 5.78 7.66 9.53 11.41 13.29 2.22

W1.50 1.50 1.50 1.50 1.50 1.50 1.56 1.56 1.56 1.56 1.56 1.56 1.56 1.56 1.56 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 3.00

H1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.50

Hex Key1/8 1/8 1/8 1/8 1/8 1/8 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16

Catalog NumberBIBD350-3 BIBD350-4 BIBD350-5 BIBD350-6 BIBD350-8 BIBD350-10 BIBD350-12 BIBD350-14 BIBD600-2 BIBD600-3 BIBD600-4 BIBD600-5 BIBD600-6 BIBD600-8 BIBD600-10 BIBD600-12 BIBD600-14 BIBD750-2* BIBD750-3* BIBD750-4* BIBD750-6* BIBD750-8* BIBD750-10* BIBD750-12* BIBD750-14*

# of Wire Range Ports (AWG/kcmil)3 4 5 6 8 10 12 14 2 3 4 5 6 8 10 12 14 2 3 4 6 8 10 12 14 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750

L3.13 4.04 4.95 5.86 7.68 9.50 11.32 13.14 2.56 3.77 4.97 6.17 7.37 9.78 12.97 15.53 18.09 2.87 4.25 5.63 8.37 11.13 13.87 16.63 19.37

W3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.38 3.38 3.38 3.38 3.38 3.38 3.38 3.38

H2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 2.75 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00

Hex Key5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8

NOTE: Only 1 conductor per port allowed. * Not UL Listed

BURNDYMechanicalBURNDY UNITAPA-52

CLEAR INSULATED MULTIPLE TAP CONNECTORS MOUNTING VERSION TYPE BIBS-MT, BIBD-MTThe BIBS-MT and BIBD-MT series UNITAP offer the same multi-port capabilities as the standard UNITAP connectors except these -MT types are provided with two isolated mounting holes at both ends of the connector for direct mounting to a trough, gutter or wireway. They will accommodate up to standard 1/4 hardware.

Fig. 1

Fig. 2

MULTI-PORT Single-Sided EntryCatalog Number BIBS2/04MT BIBS2/06MT BIBS2/08MT BIBS2/010MT BIBS2/012MT BIBS2504MT BIBS2506MT BIBS2508MT BIBS25010MT BIBS25012MT BIBS3504MT BIBS3506MT BIBS3508MT BIBS35010MT BIBS35012MT BIBS6004MT BIBS6006MT BIBS6008MT BIBS60010MT BIBS60012MT # of Fig # Ports 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 Wire Range (AWG/Kcmil) #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #10-250 #10-250 #10-250 #10-250 #10-250 #10-350 #10-350 #10-350 #10-350 #10-350 #4-600 #4-600 #4-600 #4-600 #4-600 L 3.95 5.29 6.64 7.98 9.33 5.53 7.40 9.28 11.16 13.03 5.61 7.43 9.25 11.07 12.89 7.59 10.16 12.72 15.28 17.84 W 1.31 1.31 1.31 1.31 1.31 2.07 2.07 2.07 2.07 2.07 2.32 2.32 2.32 2.32 2.32 2.38 2.38 2.38 2.38 2.38 H 1.38 1.38 1.38 1.38 1.38 2.13 2.13 2.13 2.13 2.13 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75 2.75 Hex Key 3/16 3/16 3/16 3/16 3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8 3/8

MULTI-PORT Double-Sided EntryCatalog Number BIBD2/04MT BIBD2/06MT BIBD2/08MT BIBD2/010MT BIBD2/012MT BIBD2504MT BIBD2506MT BIBD2508MT BIBD25010MT BIBD25012MT BIBD3504MT BIBD3506MT BIBD3508MT BIBD35010MT BIBD35012MT BIBD6004MT BIBD6006MT BIBD6008MT BIBD60010MT BIBD60012MT # of Fig # Ports 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 4 6 8 10 12 Wire Range (AWG/Kcmil) #14-2/0 #14-2/0 #14-2/0 #14-2/0 #14-2/0 #10-250 #10-250 #10-250 #10-250 #10-250 #10-350 #10-350 #10-350 #10-350 #10-350 #4-600 #4-600 #4-600 #4-600 #4-600 L 3.95 5.29 6.64 7.98 9.33 5.53 7.40 9.28 11.16 13.03 5.61 7.43 9.25 11.07 12.89 7.59 10.16 12.72 15.28 17.84 W 1.56 1.56 1.56 1.56 1.56 2.64 2.64 2.64 2.64 2.64 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 H 1.38 1.38 1.38 1.38 1.38 2.13 2.13 2.13 2.13 2.13 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75 2.75 Hex Key 3/16 3/16 3/16 3/16 3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8 3/8

BURNDYMechanicalBURNDY UNITAP THE MOLEFor Direct Burial 600V, 90CDesigned specifically for direct burial applications, the MOLE inline splice/reducer is made with a specialized plastisol material that forms a rugged weathertight connection. A-53

Features and Benefits UL486D Listed for direct burial. AL9CU Dual-rated for copper and aluminum applications. 600V 90C. Plastisol covered AL6061-T6 aluminum body saves time by eliminating the need for heat shrink. Oxide inhibitor pre-installed preventing moisture and contaminants from entering contact area. Range-taking capability reduces the number of connectors carried in inventory.

Catalog NumberBISR4-DB BISR1-DB BISR3/0-DB BISR250-DB

Number of Ports2 2 2 2

Wire Range (AWG/kcmil)#6 - 4 AWG #2 - 1 AWG 1/0 - 3/0 AWG 4/0 - 250 kcmil

Dimensions (Inches) L W H4.30 6.30 6.25 6.70 0.80 0.93 0.99 1.18 1.28 1.59 1.84 2.03

Hex Key (Torque) (In.-lbs.)1/8 (50) 5/32 (130) 3/16 (220) 5/16 (360)

Wire Strip Length7/8 1-3/32 1-3/32 1-5/16

BISR-DB = BURNDY Inline Splice/Reducer Direct Burial

BURNDYMechanicalUV RATED BLACK UNITAPA-54

For Direct Burial 600V, 90C

Features and Benefits UV Rated Plastisol covered AL6061-T6 aluminum body saves time by eliminating the need for taping. Oxide inhibitor pre-installed inhibits moisture and contaminants from entering the contact area. Range-taking capability reduces the number of connectors carried in inventory. UL486B Listed, AL9CU, 600V 90C

Catalog Number1PL42 1PLO42 1PL2/02 1PLO2/02 1PL2502 1PLO2502 1PL3502 1PL6002 1