Top Banner
Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration
23

Fault Tolerant Configuration

Jan 13, 2016

Download

Documents

hada

Fault Tolerant Configuration. Host System and FT | JAN 2 0 1 3. Host System Software LiNC-NXG, LiNC-Plus, LiNC-XS, EBI* Fault Tolerant Architecture FTC Controllers Door Modules Dual Door Module (DDM) Single Door Module (SDM) Ethernet Communication Up to 3 Communication Ports - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Fault Tolerant Configuration

Host System and FT | JAN 2 0 1 3

Fault Tolerant Configuration

Page 2: Fault Tolerant Configuration

• Host System Software – LiNC-NXG, LiNC-Plus, LiNC-XS, EBI*

• Fault Tolerant Architecture– FTC Controllers– Door Modules

• Dual Door Module (DDM)

– Single Door Module (SDM)

• Ethernet Communication• Up to 3 Communication Ports

– Ethernet– PoE – XBee PRO DigiMesh

Fault Tolerant System Architecture

Page 3: Fault Tolerant Configuration

• Fault Tolerant Controller (FTC)– Distributed Intelligent Controllers with Hydra

• Door Modules– DDM series (Dual Door Module)

• Any Reader or Biometric Type• Supervised Reader Detect

– SDM (Single Door Module)• Single Door controller (No reader)

– SDM ER series• All inclusive (Multi-Tech Reader and Controller)

Controller Components

Page 4: Fault Tolerant Configuration

Basic Fault Tolerant Archtecture

Ethernet Network

Page 5: Fault Tolerant Configuration

FT Configuration – “CLIQUE”

• A Clique is a “group” of Fault Tolerant Controllers and Door Modules– Maximum 8 – Fault Tolerant Controllers– Maximum 112 – Door Modules (DDM/SDM)

• Up to 224 readers

• A Clique Communicates Information within itself and to the Host

• No limit to the number of Cliques per system

Page 6: Fault Tolerant Configuration

Design Recommendations

• Fault Tolerant Controller Capabilities– Monitor and Control up to 16 DDM or SDM

• Clique Size– Up to 8 FTC– Total 112 door control modules

• Up to 224 readers if all controllers are DDM

Page 7: Fault Tolerant Configuration

Typical Enterprise Network Application

Clique 1

Clique 4 Clique "n"

Clique 2

Clique 3

Page 8: Fault Tolerant Configuration

Basic Door Architecture

Fingerprint Reader with RFID Reader

RFID Readerwith Keypad

DDM

Reader Cable Requirements to the Door:

6 conductor, 22 AWG, Stranded with overall Shield. Fingerprint Reader will require its own power cable(2 conductor, 18 AWG, stranded).

Motion DetectorEthernet

Battery Output

Page 9: Fault Tolerant Configuration

Door Installation Configuration A

Non Secured Side Secured Area

REXButton

Door Strike

Door Status

CardReader

Page 10: Fault Tolerant Configuration

Secured Area

PIR(REX)

Door Strike

Door Status

CardReader

Magnetic Door Lock

Door Installation Configuration B

Non Secured Side

Page 11: Fault Tolerant Configuration

Door Installation Configuration C

Non Secured Side Secured Area

Card Reader

Door Strike

Door Status

CardReader

Page 12: Fault Tolerant Configuration

Typical DDM Cable Connections

To Network Switch

Reader

REX

Door Lock

2 Conductor 18 AWG Stranded

2 Conductor 22 AWG Stranded

CAT 5 or 6 Cable

6 Conductor 22 AWG, Stranded

DDM

Page 13: Fault Tolerant Configuration

Door Connections for ALL PCSC Products

Wiegand Reader Connection

REX

Door Status

Door LockDoor Lock

N.C.N.O.

Common

Door Connections

Page 14: Fault Tolerant Configuration

Single Door Module (SDM)

SDM ERP40

Page 15: Fault Tolerant Configuration

• SDM– Single Door Controller– PoE Communication– Any Wiegand Card Technology or Biometric

Reader– Door Status, REX, Door Lock Output

• SDM “ER” series– Same as Above– Incorporated Reader

• Proximity• Multi-Technology

Single Door Module Configurations

Page 16: Fault Tolerant Configuration

Single Cable Installation—SDM ER Series

Controller • Ethernet or PoE• Door Lock Output• Door Sense Input• Request to Exit (REX)• Power Input

Reader - Incorporated

• Proximity• Multiclass

Page 17: Fault Tolerant Configuration

Single Cable Application—SDM ERP

Door Lock

Door Status

To PoE Switch

SDM

Page 18: Fault Tolerant Configuration

SDM—Controller ONLY

To PoE Switch

SDM

Reader

Lock

Door Status

Page 19: Fault Tolerant Configuration

Multi-Tenant Application

Page 20: Fault Tolerant Configuration

Legacy System Upgrade Requirements

• Latest System Software– LiNC-NXG, LiNC-Plus, LiNC-XS, EBI

• Supported Legacy Controllers– IQ, SIM, ULT series controllers

• Upgrade Controller Communications– LANU– Terminal Servers

Page 21: Fault Tolerant Configuration

Fault Tolerance Architecturewith Legacy Controllers

Page 22: Fault Tolerant Configuration

Application Solutions with Fault Tolerant

• Commercial High Rise • Enterprise Systems• Remote Managed Access• Campus Environment• Industrial• Banking• Government, HSPD compliant Cards• High Reliability• High Security Requirements

Page 23: Fault Tolerant Configuration