1 Examining the Effect of Coarse Recycled Concrete Aggregate on Moisture Damage Resistance of HMA Mixtures Hanaa Khaleel Alwan Al-Bayati 1 Ph.D. Centre for Pavement and Transportation Technology (CPATT), Department of Civil and Environmental Engineering, Faculty of Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, Canada N2L 3G1, Phone: +1-519-888- 4567× 30187 , Fax: +1-519-888-4300, E-mail: halwan@uwaterloo.ca Susan L. Tighe Ph.D., P. Eng., President 2017-2018, Canadian Society for Civil Engineering, Ph.D., P. Eng., Professor, Norman W. McLeod Professor of Sustainable Pavement Engineering, Department of Civil and Environmental Engineering, Faculty of Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, Canada N2L 3G1, Phone: +1-519-888-4567× 33152, Fax: +1-519-888-4300, E-mail: sltighe@uwaterloo.ca Principal Author: Hanaa Khaleel Alwan Al-Bayati Paper prepared for presentation at the GREEN TECHNOLOGY IN GEOTECHNICAL AND MATERIALS ENGINEERING of the 2019 Conference of the Transportation Association of Canada Halifax, NS
15
Embed
Examining the Effect of Coarse Recycled Concrete Aggregate ...
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Moisture Damage Resistance of HMA Mixtures
Hanaa Khaleel Alwan Al-Bayati1
Ph.D. Centre for Pavement and Transportation Technology (CPATT),
Department of
Civil and Environmental Engineering, Faculty of Engineering,
University of Waterloo,
200 University Avenue West, Waterloo, Ontario, Canada N2L 3G1,
Phone: +1-519-888-
4567× 30187 , Fax: +1-519-888-4300, E-mail:
halwan@uwaterloo.ca
Susan L. Tighe
Ph.D., P. Eng., President 2017-2018,
Canadian Society for Civil Engineering,
Ph.D., P. Eng., Professor, Norman W. McLeod Professor of
Sustainable Pavement
Engineering, Department of Civil and Environmental Engineering,
Faculty of
Engineering, University of Waterloo, 200 University Avenue West,
Waterloo, Ontario,
Canada N2L 3G1, Phone: +1-519-888-4567× 33152, Fax:
+1-519-888-4300, E-mail:
sltighe@uwaterloo.ca
Paper prepared for presentation at
the GREEN TECHNOLOGY IN GEOTECHNICAL AND MATERIALS
ENGINEERING
of the 2019 Conference of the
Transportation Association of Canada
Moisture damage in asphalt mixtures has become a widely discussed
topic due to its high influence on asphalt mixture behavior.
Moisture damage is a phenomenon that relates to the loss of
stiffness and strength of asphalt mixtures because of exposure to
moisture under the influence of mechanical loading of traffic,
which results in what is known as stripping. Moisture damage that
leads to the deterioration in the integrity of asphalt pavement
plays a key role in the occurrence of other distress types
including fatigue cracking, rutting, etc. Therefore, this study
aims to evaluate the influence of the addition of coarse recycled
concrete aggregate (CRCA) on the tensile strength and moisture
sensitivity of Ontario Superpave mixtures. Mix designs of asphalt
mixtures were performed for two types of CRCA at various
proportions (0%, 15%, 30%, and 60%). The impact of CRCA types on
the tensile strength and moisture sensitivity of asphalt mixtures
were evaluated. The obtained results also are statistically
analyzed. The findings showed that the tensile strength of hot mix
asphalt (HMA) mixtures that included different CRCA types with
various proportions have higher values than the control mix.
Additionally, the laboratory outcomes revealed that all TSR values
for mixtures that included different CRCA types with various
percentages are higher than the minimum required value of MTO
specifications. This indicated a highly successful performance for
these mixtures that included CRCA. The results of the ANOVA
analysis showed that there is a statistically insignificant effect
of CRCA type, and proportion on the TSR. However, the type of CRCA
has a higher effect on the results of TSR compared to the CRCA
percentage.
Key words: Asphalt mixtures, Coarse recycled concrete aggregate
(CRCA), Moisture damage, Tensile strength.
1. Introduction
Asphalt concrete represents one of the main materials required for
constructing road pavement (Liu et al., 2017). Generally, it
consists of approximately 95% aggregate and 5% asphalt material. In
asphalt pavement, the aggregate particles represent a structural
framework (skeleton) for the mixture, whereas, the asphalt binder
works like a sticky substance. The physical properties of both
coarse and fine aggregates have a considerable influence on the
asphalt pavement performance (Arabani & Azarhoosh, 2012). It
was estimated that one kilometre of road approximately 150 mm thick
and 10 m wide needs roughly 3750 tonnes of hot mix asphalt (HMA)
mixture, whereas another study showed that a kilometre of pavement
construction required 12,500 tonnes of natural aggregate (Zoorob
and Suparma, 2000; Ektas and Karacasu, 2012).
In terms of natural resources, natural aggregates are quickly
becoming exhausted worldwide due to an overwhelming demand for raw
materials. Simultaneously, tremendous amounts of construction and
demolition (C&D) waste are generated from various human
activities including but not limited to construction, renovation
and the
3
demolition of aged buildings and civil engineering structures.
Recently, the amount of C&D waste generated annually has been
estimated at 1,183 million tonnes worldwide (Purushothaman et al.,
2014). To solve various problems including lowering the consumption
of virgin materials, decreasing waste materials in landfills
(Hossain et al. 2016; Jin et al., 2017) and reducing environmental
problems, the utilization of recyclable waste materials, especially
recycled concrete, as a sustainable solution has become highly
required and an urgent priority in the asphalt industry.
Numerous studies have been conducted to investigate the use of RCA
in HMA mixtures (Shen & Du, 2004; Paranavithana &
Mohajerani, 2006; Wong et al., 2007; Du & Shen, 2007; Pérez et
al., 2009; Wu et al., 2013; Pasandín & Pérez, 2014; Radevi et
al., 2017). Pérez et al., (2009) evaluated the resistance of
asphalt mixtures that included RCA with natural aggregate with
respect to fatigue cracking and dynamic stiffness. The findings of
the study revealed that the mixture that included RCA had a higher
dynamic modulus than mixtures without RCA even if a large amount of
bitumen is used. Zhu et al. (2012) concluded that the addition of
CRCA without treatment causes poor moisture resistance and
low-temperature flexibility. The addition of treated CRCA, using a
pre-coating method with liquid silicone resin, works to improve
these properties. The addition of treated CRCA improves strength,
absorption, and adhesion with asphalt while it has a negative
effect on the permanent deformation at elevated temperatures.
However, mixture properties at elevated temperatures are still
acceptable.
Moisture damage in asphalt mixtures has become a widely discussed
topic due to its high influence on asphalt mixture behavior.
Moisture damage plays an important role in many different types of
distress including rutting, fatigue cracking, raveling, and
potholes (Moraes et al., 2011; D’Angelo and Anderson, 2003).
Therefore, the reduction of moisture damage impact is becoming one
of the significant challenges for researchers, agencies and
departments of transportation. In asphalt pavements, moisture
damage can be defined as deterioration of mechanical properties
such as stiffness, durability and strength due to the presence of
water. Based on the literature review, it is noted that some
studies indicated that asphalt mixtures which include RCA have
higher moisture susceptibility than natural aggregate asphalt
mixtures (Pasandín and Pérez, 2013). However, some other
investigations revealed that the addition of RCA as a coarse or
fine aggregate can improve the moisture susceptibility of asphalt
mixtures (Du and Shen, 2007, Cho et al., 2011, Chen et al., 2011).
Therefore, the main objective of this research is to evaluate the
possible application of different types and various proportions of
coarse recycled concrete aggregate (CRCA) in typical Ontario HMA
mixtures in terms of tensile strength and moisture damage.
2. Materials and Methods
2.1 Materials
Natural aggregate and one filler type that is commonly utilized for
preparing asphalt mixtures; namely, dust plant, were obtained from
the Miller Group and one type of asphalt
4
binder, namely, PG 64-28 was used. In this research, two different
RCA types were utilized, RCA#1 was provided from a ready-mix
concrete plant through the crushing process of concrete that has
unsatisfactory properties, performance, and age. Hence, RCA#1 can
be categorized as fresh concrete that has not been used in civil
engineering works. The second type, RCA#2, is classified as a
granular A according to the Ontario provincial standard
specifications (OPSS.MUNI 1010). RCA#2 was produced by Steed and
Evans Limited in St. Jacobs, Ontario. In this study, CRCA is
defined as the sieve fraction retained between 4.75 and 19 mm. The
optical images of natural aggregate, RCA#1 & RCA#2 are shown in
Figure 1-a, b, and c, respectively.
1-a. natural aggregate 1-b. RCA#1 1-c. RCA#2
Figure 1: Optical images of natural aggregate & RCA types
2.2 Methods
2.2.1 Preparation of Natural Aggregate & CRCA
RCA was washed thoroughly so that all noticeable impurities such as
wood chips and others were removed. Then, all-natural aggregate
& RCA were dried in an oven at 105 ± 5 °C for 24 hr before the
sieve analysis procedure. RCA was sieved with a 4.75 mm sieve to
ensure that only the coarse aggregate was retained. The aggregate
gradation of both of natural aggregate and RCA is provided in
Figure 2.
5
2.2.2 Superpave Mix Design
The Superpave mix design was carried out based on AASHTO R 30-02
(2010). The design is equivalent to a single-axle load ranging
between 10 and 30 million. Superpave mixture design procedure was
performed according to the nominal maximum aggregate size (NMAS),
19 mm. As a partial substitute for coarse natural aggregate, four
different proportions of CRCA (0%, 15%, 30%, and 60%) were added
for the included CRCA mixtures. The gradation with different types
and percentages of CRCA, targeted the mix design of Miller group,
and ministry transportation Ontario (MTO) specifications are
numerically tabulated in Table 1. Table 2 shows the volumetric
properties of different HMA mixtures that were prepared in this
study. All experimental tests were conducted in the Centre for
Pavement and Transportation Technology (CPATT) in the University of
Waterloo.
6
Table 1. Gradations with various CRCA proportions, targeted mix
design, and MTO specifications
Sieve Size, mm
Passing (%) for Different CRCA Percentages The Target of Mix
Design
MTO Limitation
0.0% CRCA
15% CRCA#1
30% CRCA#1
60% CRCA#1
30% CRCA#2
60% CRCA#2
25 100 100 100.0 100.0 100 100.0 100 100 19 95.2 95.2 95.3 95.2
96.6 97.3 96.8 100 - 90 16 89.0 88.7 88.5 87.4 86.6 82.9 90.6 90 -
23
12.5 81.8 81.1 80.5 78.2 73.9 64.1 83 9.5 73.2 72.3 71.8 69.0 67.8
59.1 73.3 6.7 63.3 63.0 63.1 61.0 61.5 55.1 63.3 4.75 57.1 56.7
55.9 53.8 56.0 51.7 55.9 2.36 42.8 42.8 41.3 41.2 41.8 40.9 43.5 49
- 23 1.18 30.7 30.7 30.5 30.5 31.2 30.5 32.5 0.6 22.9 23.0 23.6
23.6 24.3 23.6 25.1 0.3 10.2 10.3 10.3 10.3 10.3 10.3 11.8 0.15 5.4
5.5 5.6 5.5 5.5 5.5 5.5
0.075 2.1 2.2 2.2 2.1 2.1 2.1 3.8 8 - 2
Table 2. Volumetric characteristics of mixtures with different
types and percentages of
CRCA
MTO Specification
OAC AC (%) 4.83 4.90 5.31 5.71 5.12 5.20 - VMA (%) 14.50 13.60
13.66 16.18 14.00 13.27 13 min. VFA (%) 72.50 70.80 70.70 74.80
71.40 70.03 65-75 Vv (%) 4.00 4.00 4.00 4.04 4.00 4.00 4.0 Gmb
2.400 2.395 2.373 2.351 2.384 2.367 -
2.2.3 Indirect Tensile Strength Test (Modified Lottman Test- AASHTO
T283)
The adoption of this method was by AASHTO in 1985. It was a highly
accepted method from many states and transportation departments
therefore it was applied in the Superpave mix design procedures to
evaluate moisture susceptibility of asphalt mixtures. The ITS was
determined for mixtures that included both types of CRCA with
various proportions in accordance with AASHTO T-283 method. By
using a Superpave gyratory compactor with a height of 95 ± 5 mm,
the samples with air voids of 7% ± 0.5 were compacted. The
compacted samples were divided into two main groups in which three
specimens for each group; namely, unconditioned (control) strengths
and conditioned strengths. While the test temperature and loading
rate were 25 °C and 50 mm/min,
7
respectively, for the unconditioned samples, the other specimens
were applied for moisture-conditioning. The conditioning firstly
includes achieving a saturation between 70% and 80% for the
samples. At a minimum period of 16 hrs, the samples then were
placed in a freezer at a temperature of -18 ± 3 °C. After that, the
specimens were placed in a hot water bath at 60 ±1 °C for 24 ±1 hr.
After the hot water bath, the samples were kept in a water bath at
a temperature of 25 ±0.5 °C for 2 hrs ±10 mins before the specimens
were prepared for testing. Thus, the TSR ratio was determined by
dividing conditioned strength by unconditioned strength. According
to the standard OPSS 1151 (2007), the TSR value should be more than
80%. The ITS and TSR are calculated using the following equations
(Solaimanian et. al., 2003; Zollinger, 2005):
= 2000∗
∗ ∗ ……………………………………… (1)
Where: ITS = indirect tensile strength, kPa; P = maximum load, N; t
= sample thickness before test, mm; D = sample diameter, mm.
=
………………………………… (2)
Where: TSR = tensile strength ratio; ITScon. = tensile strength of
conditioned; ITSuncon. = tensile strength of unconditioned. 3.
Results and Discussion
3.1 Physical and Mechanical Properties of Natural Aggregate and
CRCA
Table 3 presented the outcomes of the physical and mechanical
properties of natural aggregate and CRCA for both different CRCA
types. From the perspective of physical properties, namely, bulk
relative density (BRD) and water absorption, a considerable
difference is registered between natural aggregate and both
CRCA#1& 2. In addition, a relative variation is observed in the
physical properties between CRCA#1 and CRCA#2. These findings
confirm the outcomes of previous investigations which demonstrated
that the absorption capacity of RCA is significantly higher than
natural aggregate (Wu et al., 2013; Pasandín & Pérez, 2014).
Adhered mortar, which has a higher porosity than natural aggregate,
results in the RCA being more susceptible to absorbing more water
compared to natural aggregate (Al-Bayati et al., 2016). Hence, the
presence of adhered mortar leads to increased water absorption,
lowered density, and weaker bond strength (Wong et al., 2007). In
terms of mechanical properties, abrasion loss and adhered mortar
loss various observations can be indicated. Compared to CRCA#1, the
outcomes indicate that the abrasion loss of CRCA#2 is significantly
lower and closer to the natural aggregate value, indicating a
strong type of CRCA. Such a strong type of CRCA has a lower
quantity of
8
attached mortar; therefore, the findings of the adhered mortar loss
are consistent with the abrasion loss results.
Table 3: Physical and mechanical properties of natural aggregate
and CRCA
Aggregate Type Bulk Relative Density (BRD)
ASTM (C 127)
Fractured Particles, % ASTM (D5821)
Natural aggregate 2.658 0.80 - 15.89 95.50 CRCA#1 2.295 5.91 3.02
23.57 89.90 CRCA#2 2.421 3.74 1.08 16.03 95.72
3.2 Influence of CRCA on the Tensile Strength
ITS is usually used to measure the tensile strength of asphalt
mixtures, which could be further used for evaluating different
relevant behaviours such as road surface cracking, permanent
deformation, and stripping (Lee et al., 2012).
To evaluate the effect of CRCA types on tensile strength, Figure 3
demonstrates the average of the laboratory outcomes of conditioned
and unconditioned ITS samples of the mixtures that included CRCA#1
and CRCA#2 with various proportions. For all cases, it is important
to mention that the worst tensile strength is recorded for the
control mixture (0% CRCA) among various tensile strength values,
indicating a successful behaviour for the addition of various CRCA
types with different proportions. It is observed that the mixtures
that included CRCA#1 & 2 had the same behavior trend in terms
of tensile strength. Generally, an increase in the CRCA percentages
leads to a decrease in the ITS values. Additionally, the mixtures
that included CRCA#2 up to 60% exhibited better tensile strength in
both ITS conditioned and unconditioned state, indicating a higher
tensile strength than the mixtures that included the same
proportion of CRCA#1. It is interesting to note that the maximum
ITS values recorded for 30% CRCA#2 for unconditioned and
conditioned samples are 941.5 kPa and 856.5 kPa with an increase of
85.6% and 86.7%, respectively. This is followed by the ITS values
of 60% CRCA#2 addition for both unconditioned and conditioned
samples with an increase of 71.5% and 56.8%, respectively. This
could be explained by the existence of a high proportion of adhered
mortar attached to the CRCA#1 surface, which is more brittle under
the impact of the compaction of wheel loads, resulting in a poor
adhesion between the CRCA particles and asphalt binder. Hence, it
can be stated that the type of CRCA has a considerable effect on
the tensile strength of the mixture. In conclusion, the HMA
mixtures that include CRCA with different types can tolerate higher
strains before their failure, which means they are more likely to
resist cracking compared to asphalt mixtures that include natural
aggregate with a low tensile strain at failure.
9
Figure 3: ITS for mixtures including different CRCA types with
various proportions
3.3 Effect of CRCA Addition on the Moisture Damage
Moisture sensitivity, also known as moisture damage, refers to a
type of degradation that mainly influences the mechanical
characteristics of an asphalt mixture because of the presence of
water (Pasandín & Pérez, 2013). To obtain an asphalt mixture
that can successfully resist moisture and water damage, the minimum
required TSR value should be 80 % (Pérez et al., 2012). 3.3.1
Influence of CRCA Proportion
Figure 4 shows the behaviour of TSR values of mixtures including
different proportions of CRCA#1. The laboratory results
demonstrated that all TSR values are higher than 80%, representing
the minimum required value of MTO specification for HMA mixtures,
resulting in a highly successful behaviour for different CRCA#1
proportion. The values of TSR increases when the CRCA addition is
increased even with a high CRCA proportion of 60%. Surprisingly,
among various TSR values, the worst TSR value is recorded for the
mixture of control mix (0% CRCA). This could be attributed to a
good adhesion of CRCA with asphalt binder due to the roughness of
adhered mortar surface and the angularity of CRCA particles that
can exist as a result of the impact of the crushing process. It is
noteworthy that the values of TSR for mixtures that included
various proportions of CRCA#1 are strongly correlated due to
obtaining a considerable regression. A polynomial equation reflects
well the behaviour of the relation between the TSR values and
proportions of CRCA#1 addition. Due to the importance of the
moisture sensitivity test for
10
cold weather countries, these outcomes are very promising and
important for RCA applications.
Figure 4: TSR values for mixtures including various proportions of
CRCA#1.
3.3.1 Effect of CRCA Types
Figure 5 displays the laboratory outcomes of TSR values of asphalt
mixtures that included different CRCA types with various
proportions to explore the effect of CRCA type on the moisture
sensitivity of mixtures. For both types of CRCA, it is interesting
to note that the TSR values are higher than 80% for all
proportions. These results strongly indicate a successful
utilization of CRCA in asphalt mixtures. Additionally, it is
important to note that the mixtures that included CRCA#1 or CRCA#2
have different behaviour trends in terms of TSR. With CRCA#1
addition, the TSR gradually increased to reach a value of 95.3% for
the mixture that included 60% CRCA#1, whereas TSR followed an
opposite behaviour when CRCA#2 addition reached a similar
proportion. Furthermore, the mixtures that included CRCA#1 up to
60% exhibited a better moisture resistance and registered a higher
tensile strength ratio than the mixtures that included the same
proportion of CRCA#2. Therefore, it can be stated that the outcomes
of moisture sensitivity seem to be completely opposite compared to
the ITS test regarding the influence of the type of RCA. In
conclusion, the results indicate that the moisture sensitivities of
mixtures that included CRCA are highly affected by the type of
CRCA.
11
Figure 5: TSR values for mixtures including different CRCA types
with various
proportions.
3.4 Statistical Analysis of the Obtained Results
Table 4 summarizes statistical aspects of ITS including standard
deviation and coefficient of variation. The statistical results
generally revealed that the coefficients of variation of the
unconditioned ITS at the temperature of 25 °C are higher values
than the coefficients of variation of the conditioned ITS. This
indicates there is a possibility to use conditioned ITS as a
parameter to rank the tensile strength of HMA mixtures. However,
there is some opposite expectation to the behaviour of mixtures
that included 60% CRCA#2. Heterogeneity of CRCA and its inferior
properties such as surface texture, porosity, and density could
possibly have an effect on the ITS value for different asphalt
mixtures.
A one-way ANOVA analysis was performed to examine the influence of
CRCA proportion (0%, 15%, 30%, and 60%) on the TSR value of asphalt
mixtures. The results indicated that the CRCA percentage has an
insignificant impact on TSR with a p-value of (0.971) and Factual
(0.076434) < Fcritical (4.066). This indicates that the
variation in the CRCA content will not affect the moisture
sensitivity of HMA mixtures. To obtain a better understanding, a
two-way ANOVA analysis was carried out for different mixtures to
investigate the influence of various parameters on TSR values. The
mentioned parameters include: different CRCA proportions (30%, and
60%); various CRCA types. Surprisingly, the findings indicated that
the effects of these variables act independently due to an
insignificant interaction between the CRCA type and CRCA’s
12
percentage with a p-value of (0.2843). However, the type of CRCA
has a higher effect on the results of TSR than the CRCA percentage
in terms of studying the impact of CRCA type and its proportion.
The findings of two-way ANOVA analysis of TSR values are presented
in Table 5.
Table 4: Statistical Analysis of the Results of ITS
Mixture Std. dev. for
ITS (%)
Control mix (0% CRCA) 58.11 11.46 24.55 5.35 15% CRCA#1 87.09 9.58
31.52 3.80 30% CRCA#1 32.84 3.85 24.30 3.11 60% CRCA#1 69.31 9.67
64.26 9.40 30% CRCA#2 110.12 11.70 63.93 7.46 60% CRCA#2 16.13 1.85
15.66 2.18
Table 5: Results of Two-Way ANOVA Analysis: P-Value and Sum of
Squares of TSR
Source of Variation TSR, %
F- critical 5.3177
4. Conclusions Based on the obtained laboratory results, the
following conclusions can be drawn: The mixtures that included
CRCA#1 or CRCA#2 have the same behavior trend in terms
of ITS for both conditioned and unconditioned states. Generally,
when CRCA increases, the ITS decreases. However, the mixtures that
included CRCA#2 up to 60% exhibited a better tensile strength for
both ITS conditioned and unconditioned states, registering a higher
tensile strength than the mixtures that included the same
proportion of CRCA#1
13
It is interesting to note that the maximum ITS values recorded for
30% CRCA#1 and CRCA#2 for both unconditioned and conditioned
samples, registered increases of 68%, 70%, 85.6%, and 86.7%,
respectively. This is followed by the ITS values of the mixtures
that included 60% CRCA1# and CRCA#2 for both unconditioned and
conditioned samples with increases of 41.4%, 49.0% 71.5% and 56.8%,
respectively.
The findings indicated that all TSR values for mixtures that
included CRCA with different types and proportions are higher than
the minimum required value of MTO specifications. However, it is
important to note that the mixtures that included CRCA#1 or CRCA#2
have different behaviour trends in terms of TSR.
From the perspective of the type of CRCA, the mixtures that
included CRCA#1 or
CRCA#2 exhibited different behaviour trends in terms of TSR.
Additionally, the
mixtures that included CRCA#1 up to 60% exhibited a better moisture
resistance and
registered a higher tensile strength ratio than the mixtures that
included the same
proportion of CRCA#2.
From the perspective of TSR, the results of the ANOVA analysis
revealed that there is no significant effect of CRCA type and
proportion, on the TSR values. However, the type of CRCA has a
higher effect on the results of TSR compared to the CRCA
percentage.
Acknowledgements The authors would like to gratefully acknowledge
the funding provided by Ministry of Higher Education and Scientific
Research/Iraq through Iraqi Scholarship/Doctoral Program. The
authors are also would like to thank Miller Group in Toronto,
Ontario for supplying natural aggregate. References:
Al-Bayati, H. K. A., Das, P. K., Tighe, S. L., and Baaj, H. 2016.
“Evaluation of various treatment methods for enhancing the physical
and morphological properties of coarse recycled concrete
aggregate.” Construction and Building Materials. 112:
284-298.
Arabani, M., and Azarhoosh, A. R. 2012. “The effect of recycled
concrete aggregate and steel slag on the dynamic properties of
asphalt mixtures”. Construction and Building Materials. 35: 1-7.
Chen, M., Lin, J., and Wu, S. 2011. “Potential of recycled fine
aggregates powder as filler in asphalt mixture”. Construction and
Building Materials. 25 (10). 3909-3914.
Cho, Y. H., Yun, T., Kim, I. T., & Choi, N. R. 2011. “The
application of recycled concrete aggregate (RCA) for hot mix
asphalt (HMA) base layer aggregate”. KSCE Journal of Civil
Engineering, 15(3), 473-478.
14
D’Angelo, J. O. H. N., & Anderson, R. M. 2003. “Material
production, mix design, and pavement design effects on moisture
damage”. In Moisture Sensitivity of Asphalt Pavements: A National
Seminar (pp. 187-201).
Du, J. C., and Shen, D. H. 2007. “Evaluation of Construction
Material Recycling for Hot Mix Asphalt”. Journal of Environmental
Engineering & Management. 17 (4): 243-248.
Ektas, S., and Karacasu, M. 2012. “Use of Recycled Concrete in Hot
Mix Asphalt and an ANN model for Prediction of Resilient Modulus”.
Ekoloji. 21 (83): 53-60.
Hossain, M.U., Poon, C.S., Lo, I.M., Cheng, J.C. 2016. “Comparative
environmental evaluation of aggregate production from recycled
waste materials and virgin sources by LCA”. Resour. Conserv.
Recycl. 109, 67–77.
Jin, Ruoyu, Li, Bo, Zhou, Tongyu, Wanatowski, Dariusz, Piroozfar,
Poorang. 2017. “An empirical study of perceptions towards
construction and demolition waste recycling and reuse in China”.
Resour. Conserv. Recycl. 126 (2017), 86–98.
Lee, C. H., Du, J. C., and Shen, D. H. 2012. “Evaluation of
pre-coated recycled concrete aggregate for hot mix asphalt”.
Construction and Building Materials. 28 (1). 66-71.
Liu, J., Zhao, S., Li, P., Saboundjian, S. 2017. “Variability of
composition, volumetric, and mechanic properties of hot mix asphalt
for quality assurance”. J. Mater. Civ. Eng. 29 (3). D4015004.
Moraes, R., Velasquez, R., & Bahia, H. 2011. “Measuring the
effect of moisture on asphalt-aggregate bond with the bitumen bond
strength test”. Transportation Research Record: Journal of the
Transportation Research Board, (2209), 70-81.
Paranavithana, S., and Mohajerani, A. 2006. “Effects of recycled
concrete aggregates on properties of asphalt concrete”. Resources,
Conservation and Recycling. 48 (1): 1-12.
Pasandín, A. R., & Pérez, I. 2013. “Laboratory evaluation of
hot-mix asphalt containing construction and demolition waste”.
Construction and Building Materials, 43, 497-505.
Pasandín, A. R., and Pérez, I. 2014. “Mechanical properties of
hot-mix asphalt made with recycled concrete aggregates coated with
bitumen emulsion”. Construction and Building Materials. 55:
350-358.
Pérez, I., Pasandín, A. R., & Medina, L. 2012. “Hot mix asphalt
using C&D waste as coarse aggregates”. Materials & Design,
36, 840-846.
Pérez, I., Toledano, M., and Gallego, J. 2009. “Construction and
demolition debris in hot mix asphalt”. In Road Pavement Material
Characterization and Rehabilitation: Selected Papers from the 2009
GeoHunan International Conference: 141-146.
15
Purushothaman, R., Amirthavalli, R. R., & Karan, L. 2014.
“Influence of treatment methods on the strength and performance
characteristics of recycled aggregate concrete”. Journal of
Materials in Civil Engineering. 27(5): 04014168.
Radevi, A., urekovi, A., Zaki, D., and Mladenovi, G. 2017. “Effects
of recycled concrete aggregate on stiffness and rutting resistance
of asphalt concrete”. Construction and Building Materials. 136.
386-393. Shen, D. H., and Du, J. C. 2004. “Evaluation of building
materials recycling on HMA permanent deformation”. Construction and
building materials. 18 (6): 391-397.
Solaimanian, M., Harvey, J., Tahmoressi, M., & Tandon, V. 2003.
“Test methods to predict moisture sensitivity of hot-mix asphalt
pavements”. In Moisture Sensitivity of Asphalt Pavements-A National
Seminar California Department of Transportation; Federal Highway
Administration; National Asphalt Pavement Association; California
Asphalt Pavement Alliance; and Transportation Research Board.
77-110.
Wong, Y. D., Sun, D. D., and Lai, D. 2007. “Value-added utilisation
of recycled concrete in hot-mix asphalt. Waste Management”. 27 (2):
294-301.
Wu, S., Zhong, J., Zhu, J., and Wang, D. 2013. “Influence of
demolition waste used as recycled aggregate on performance of
asphalt mixture”. Road Materials and Pavement Design. 14 (3):
679-688.
Zhu, J., Wu, S., Zhong, J., & Wang, D. 2012. “Investigation of
asphalt mixture containing demolition waste obtained from
earthquake-damaged buildings”. Construction and Building Materials,
29, 466-475. Zollinger, C. J. 2005. “Application of surface energy
measurements to evaluate moisture susceptibility of asphalt and
aggregates” (Doctoral dissertation, Texas A&M
University).