Top Banner
Christopher Kelly K1000740 Environmental Practice Report
43
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Enviromental Practice

Christopher KellyK1000740

Environmental Practice Report

Page 2: Enviromental Practice

Storey Road

Gathering Room 1

Hall/AntiroomGathering Room 2

Kitchen

Lift

Plant Room

Bin/Service

Area

Page 3: Enviromental Practice

N

Site Model Sun Path11:00 Morning Light

Page 4: Enviromental Practice

Building Regulations

Part A Structure• Part B Fire Safety

• Part C Site Preparation• Part D Toxic substances

• Part E Resistance to the passage of sound• Part F Ventilation

• Part G Hygiene• Part H Drainage

• Part J Combustion appliances• Part K Protection from falling

• Part L Conservation of fuel and Power• Part M Access• Part N Glazing

• Part P Electrical safety

Code for Sustainable Homes

Page 5: Enviromental Practice

S

Key:

T

Smoke Detector

Socket Outlet

One Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating Pipe

Electrical Wire

MA

B

M

FB

FAN

Power SupplyPS

Rain Water TankT

Page 6: Enviromental Practice

Heating

Page 7: Enviromental Practice

Ground Floor Underfloor Heating, Scale 1:100

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Building Regulations:Part L Conservation, Fuel and Power and Part B, Fire Safety

Hot-water System

Wet underfloor heating systems deliver their heat evenly across rooms improving the buildings thermal mass resulting in less sudden changes in temperature.

Underfloor heating uses lower tempertures warming from the ground upwards. This warms your feet and keeps your head cool. This maximises human comfort. A condensing combination boiler works efficiently

with these low temperatures. Double glassing will be used on the windows to reduce heat loss,

MA B

Page 8: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

First Floor Underfloor Heating, Scale 1:100

Page 9: Enviromental Practice

Water Supply

Page 10: Enviromental Practice

Gathering Room 2

Kitchen

Plant Room

Bin/Service Area

B

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Ground Floor Tap Water SupplyScale: 1:50

The thickness of the pipes will be 22mm at the boiler and reduce to 15mm at the taps.

Page 11: Enviromental Practice

W/C

Storage

W/C

TerraceW/C

Storage

W/C

Lift

First Floor Tap Water SupplyScale 1:50

The toilets and sinks are placed back to back with a false wall for the services to run through. Reducing the need for more piping.

Page 12: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Tap Water Supply SectionScale: 1:50

Page 13: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Tap Cold Water Supply SectionScale: 1:50

Page 14: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Tap Warm Water Supply SectionScale: 1:50

Page 15: Enviromental Practice

Tap Water SupplyScale: 1:200

Page 16: Enviromental Practice

Tap Water SupplyScale: 1:100

Page 17: Enviromental Practice

Rain Water Collection and Re-use

Page 18: Enviromental Practice

Gathering Room 2

Kitchen

Plant Room

Bin/Service Area

TP

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Re-used Rain WaterGround Floor

Scale: 1:50

This system uses collected rain water to flush the toilets, to reduce water usage. This helps meet the code for sustainable

Homes Requirements

The rain water is collected from the roof into a storage tank and pumped when needed into the toilets.

Page 19: Enviromental Practice

W/C

Storage

W/C

T

P

TerraceW/C

Storage

W/C

Lift

Re-used Rain WaterFirst Floor

Scale: 1:50

Page 20: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Re-used Rain WaterSection

Scale: 1:50

Page 21: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Re-used Rain WaterSection

Scale: 1:50

Page 22: Enviromental Practice

Drainage

Page 23: Enviromental Practice

Gathering Room 2

Kitchen

Plant Room

Bin/Service Area

T

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Drainage Ground Floor PlanScale: 1:50

Page 24: Enviromental Practice

W/C

Storage

W/C

TerraceW/C

Storage

W/C

Lift

Drainage First Floor PlanScale: 1:50

A single stack 150 mm diameter drainage system.

Part H - Drainage

The drainage pipes are all directed vertically down into the inspection chamber below ground level..

Page 25: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Drainage SectionScale: 1:50

Page 26: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Drainage SectionScale: 1:50

Page 27: Enviromental Practice

Drainage SectionScale: 200

Page 28: Enviromental Practice

Electricity

Page 29: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

Light, Plug Socket and Light Switch PositionsSection

Scale: 1:100

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

Page 30: Enviromental Practice

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

FAN

Ground FloorPlug Socket Wiring

Scale: 1:100

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

Part P - Electrical Safety

As I am proposing a public building, a disabled lift is mandatory. This requires its own fuze box connected directly to the mains through the meter. There are four

more main circuits which go through a distribution board. These are lighting, ap-pliances, electric cooker and boiler.

All electrical wires will run through sleeves which create better access for mainte-nance and safety.

.

Lights20A

ElectricCooker30A

Boiler3A

Appliances30A

FB

Lights20A

ElectricCooker30A

Boiler3A

Appliances30A

Page 31: Enviromental Practice

Gathering Room 2

Kitchen

Plant Room

Bin/Service Area

FAN

PS M FBGathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Ground FloorPlug Socket Wiring

Scale: 1:50

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

Page 32: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

FAN

FAN

First FloorPlug Socket Wiring

Scale: 1:100

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

Page 33: Enviromental Practice

W/C

Storage

W/C

FAN

FAN

TerraceW/C

Storage

W/C

Lift

First FloorPlug Socket Wiring

Scale: 1:50

Page 34: Enviromental Practice

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

FAN

Ground FloorLighting Wiring

Scale: 1:100

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

Discharge lamps will be used for the lighting.

Page 35: Enviromental Practice

Gathering Room 2

Kitchen

Plant Room

Bin/Service Area

FAN

T

PS M FBGathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Ground FloorLighting Wiring

Scale: 1:50

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

Page 36: Enviromental Practice

TerraceW/C

Storage

W/C

Lift

FAN

FAN

First FloorLighting Wiring

Scale: 1:100

S

Key:

T

Smoke DetectorSocket OutletOne Pole Switch

Condesing Combination Boiler

Manifold

Electricity Meter

Distribution Board

Control Valve

Ventillation Fan

Thermostat

Enclosed Luminaire

Hot Water Pipe

Cold Water Pipe

Waste Pipe

Heating PipeElectrical Wire

MA

B

M

FB

FAN

Page 37: Enviromental Practice

W/C

Storage

W/C

FAN

FAN

TerraceW/C

Storage

W/C

Lift

First FloorLighting Wiring

Scale: 1:50

Page 38: Enviromental Practice

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

F

PS M FB

Ground FloorAppliance Wiring

Scale: 1:100

Page 39: Enviromental Practice

Ventilation

Page 40: Enviromental Practice

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Ground FloorVentilation

Scale: 1:100

Part F - VentilationIt is required in a common space where people gather that 1/50 of the flooring has to have ac-

cess to rapid ventilation (window opening)

Some of the rapid ventilations openings in my proposal are above 1.75m which is above the re-quired height. During direct sunlight the temperature in the main gathering room would increase

as a result of the large windows. By opening the windows to allow circulation of air, the room can cool.

Page 41: Enviromental Practice

Terrace W/C

Storage

W/C

Lift

First FloorVentilation

Scale: 1:100

Page 42: Enviromental Practice

Fire

Page 43: Enviromental Practice

Gathering Room 1

Hall/Antiroom

Gathering Room 2

Kitchen

Lift

Plant Room

Bin/Service Area

Ground Floor Fire Escape RoutesScale: 1:100

There are two exit routes out of the building in case of the event of a fire blocking one of the exits.