    Posted on 09/09/2014 by vcdx133

    (http://vcdx133.files.wordpress.com/2014/06/vcdx133e1403379365573.jpg) This post coverhow to provision a LUN (less than 239GB) for vSphere on an EMC Symmetrix VMAX using theUnisphere for VMAX GUI. The basic architecture of the VMAX is covered here(http://wp.me/p4znjP4b). If you want to build LUNs greater than 238GB, you follow the sameprocedure, but with the additional step of creating a Meta Volume (multiple TDEVs bound to asingle logical volume).

    Summary

    Create the LUN TDEV (Thin Device)Create the Storage Group and bind the TDEV to itCreate the Initiator Group with the ESXi HBA WWPNsCreate the Masking View and bind the Storage Group, Port Group and Initiator Group to itAppendix Set Port Attributes for vSphere

    Prerequisites

    You have administrator access to the EMC Symmetrix VMAX and Unisphere for VMAX GUI.EMC Symmetrix VMAX Enginuity code 5876.268.174 with EMC Unisphere for VMAX version

    1.6.0.8.Symmetrix VMAX is being configured for Virtual Volumes with FASTVP, not RegularVolumes and FASTDP.You know your storage environment, in particular, how to zonethe SAN Fabric and whichVMAX Front End Ports are being used for your ESXi hosts.This procedure breaks the tasks into their most basic steps, you can also use the ProvisionStoragewizard in the Common Tasks section on the right of the GUI. Symmetrix VMAXgurus also use symcli to script via CLI not covered here.

    Create the LUN TDEV (Thin Device)

    1. Open a Web Browser and connect to the Unisphere for VMAX GUI: http://

  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    2/11

    Bind to Pool FC R10 or R6. Then select Run Now.8. Record the serial number (0C08 in this example) of the volume when the Successfully

    created window appears. Press the Close button.

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_1.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_2.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_3.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_4.jpg)

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_4.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_1.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_3.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_2.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    3/11

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_5.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_6.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_71.jpg)

    Create the Storage Group

    1. Press the Storage icon and then the Storage Groups object.2. In the Storage Groups window, press the Create button.

    3. In the Create Storage Group window, enter the Storage Group Name (end with _SG forclarity) and the Storage Group Type Empty Storage Group. Then press the Finish buttonThen press the Close button.

    4. Press the Filter button to search for the new Storage Group, select it and then press theView Details button.

    5. In the Storage Group Details window, select the appropriate FAST Policy and press theVolumes Empty link to assign the TDEV.

    6. In the Volumes window, press the Add button.7. In the Add Volumes to Storage Group window, press the Filter button and then expand

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_6.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_71.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_5.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    4/11

    the Volume Identifier object and enter the TDEV serial number (0C08 in this example) inthe Volume ID field. Then press OK.

    8. Select the filtered TDEV and press OK.9. In the Storage Group Details window, verify that the Related Objects contains Volumes

    1.

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_81.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_91.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_101.jpg)

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_81.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_101.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_91.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    5/11

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_111.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_121.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_131.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_141.jpg)

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_121.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_141.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_111.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_131.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    6/11

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_151.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_161.jpg)

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_161.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_151.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    7/11

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_171.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_181.jpg)

    Create the Initiator Group

    1. Press the Hosts icon and then the Initiator Groups object.2. In the Initiator Groups window, press the Create button.3. In the Host Management Create Host window, select the relevant Symmetrix Serial

    Number, Host Name (end with _IG for clarity), select the Initiator WWPNs of the ESXiHost HBAs and Add them to the Initiatior Group. Then press Finish and then Close

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_171.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_181.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    8/11

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_191.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_201.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_211.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_221.jpg)

    Create the Masking View and link to the SG, PG and IG

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_201.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_211.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_221.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_191.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    9/11

    1. Press the Hosts icon and then the Masking Views object.2. In the Masking Views window, press the Create button.3. In the Create Masking View window, enter the Masking View Name (add _MV for

    clarity), Initiator Group name from the previous step, the selected Port Group that is zoned tothe ESXi Host and the Storage Group name from the previous step. Then press OK and thepress Close.

    4. You LUN (TDEV) is now ready for use. Make sure your SAN fabric has zoned the ESXi Host

    HBAs to the Front End ports of the VMAX as per the Masking View just configured.

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_231.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_241.jpg)

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_241.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_251.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_231.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    10/11

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_251.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_261.jpg)

    Appendix EMC Symmetrix VMAX Set Port Attributes for vSphere

    The Front End Ports of the VMAX require a specific set of Port Attributes to be configured tofunction with vSphere. This should already be configured as part of the Symmetriximplementation, but here it is anyway.

    1. Press the System icon and then the Front End Directors link in the Hardware section.2. Select each of the Front End Director objects that is being used with vSphere FAxxy and

    press the Set Port Attributes button.3. Make sure the following Port Attributes are Ticked: ACLX, Common Serial Number

    SCSI 3 and SPC2 Protocol Version.

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_271.jpg)

    https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_251.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_261.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_271.jpghttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_281.jpg
  • 7/21/2019 EMC Symmetrix VMAX Provisioning a LUN _ Vcdx133

    11/11

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_281.jpg)

    (https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_291.jpg)

    This entry was posted in EMC and tagged 239GB, Boot LUN, Initiator Group, Masking View,Meta Volume, Port Group, Set Port Attributes, Storage Group, Symmetrix, TDEV, UniSphere forVMAX, VMAX, vSphere. Bookmark the permalink.

    One thought on EMC Symmetrix VMAX Provisioning

    a LUN

    1. Pingback: Top vBlog 2015 Voting Open | vcdx133.com

    Blog at WordPress.com. / The Truly Minimal Theme.

    Follow

    Follow vcdx133.com

    Build a website with WordPress.com

    http://vcdx133.com/2015/03/03/top-vblog-2015-voting-open/http://vcdx133.com/tag/set-port-attributes/http://vcdx133.com/tag/storage-group/http://vcdx133.com/tag/vsphere/http://vcdx133.com/tag/masking-view/http://vcdx133.com/tag/unisphere-for-vmax/https://wordpress.com/themes/truly-minimal/https://wordpress.com/?ref=footer_bloghttp://vcdx133.com/category/emc/http://vcdx133.com/tag/boot-lun/http://vcdx133.com/tag/port-group/http://vcdx133.com/tag/239gb/http://vcdx133.com/tag/meta-volume/https://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_291.jpghttp://vcdx133.com/tag/initiator-group/http://vcdx133.com/tag/tdev/http://vcdx133.com/tag/symmetrix/http://vcdx133.com/tag/vmax/https://wordpress.com/?ref=lofhttps://vcdx133.files.wordpress.com/2014/09/unisphere_for_vmax_281.jpghttp://vcdx133.com/2014/09/09/emc-symmetrix-vmax-provisioning-a-lun/http://void%280%29/