Dwelling Details Report30/11/2011 Page 1 of 14
Property Details
House Type Of BER Rating Existing Dwelling Has a rating been previously submitted? False
ballinagappa rd Year of Construction 1978 BER Number
clane Date of Assessment 22/10/2011 Your Ref. MY AIT Project
Date of Plans 11/01/2007 MPRN No. 01234567899
Co. Kildare Planning Reference Is MPRN shared with another dwelling? False
Building Regulations None Shared BER Number
Practical assessmnet.
Phone
Co. Galway
110
8/3/2019 Dwelling Report
2/21
Dwelling Details Report30/11/2011 Page 1 of 14
AIT Devlelopers
Development Name AIT Developments
8/3/2019 Dwelling Report
3/21
Dwelling Details Report30/11/2011 Page 1 of 14
Dimension Details
Area [m] Height [m] Volume [m]
Ground Floor 214.20 2.50 535.50
First Floor 0.00 0.00 0.00
Second Floor 0.00 0.00 0.00
Third and other floors 0.00 0.00 0.00
0.00Room in roof 0.00 0.00
Total Floor Area 214.20 535.50
Living Area [m] 38.70 Living area percentage 18.07
No of Storeys 1
8/3/2019 Dwelling Report
4/21
Dwelling Details Report30/11/2011 Page 1 of 14
Ventilation Details
Air Change Rate [ac/h]
Chimneys 80
Open Flues 0
Fans & Vents 50
Gas Fires 0
No
Infiltration rate due to structure [ac/h]
Intermediate infiltration rate
Number of sides sheltered
Adjusted infiltration rate
Ventilation method
0.00
0.00
8/3/2019 Dwelling Report
5/21
Dwelling Details Report30/11/2011 Page 1 of 14
0.00
0.00
8/3/2019 Dwelling Report
6/21
Dwelling Details Report30/11/2011 Page 1 of 14
Building Elements
Windows
3.1
8/3/2019 Dwelling Report
7/21
Dwelling Details Report30/11/2011 Page 1 of 14
Heat Loss Details
Total glazed area [m] 56.23 Glazing ratio 0.11
Total glazed heat loss [W/K] 160.30 0.00
Total effective collection area [m] 20.91
Total element area [m] 639.31
Total plane heat loss [W/K] 588.00
Thermal bridging factor [W/mk] 0.15
Fabric heat loss [W/K] 684.00
Total heat loss [W/K] 815.00 3.80
8/3/2019 Dwelling Report
8/21
Dwelling Details Report30/11/2011 Page 1 of 14
Water heating
Is supplementary electric water heating used in summer? No
Is there a combi boiler?
Is there a solar water heating system?
Standard number of occupants
Daily hot water use [Litres/d] Solar hot water input, Qs [kWh/h]
Hot water energy reqs. at taps [kWh/y]
Distribution Losses [kWh/y]
Water storage volume [Litres]
Keep Hot facility
Combi-boiler loss [kWh/y] 0.00
Storage Loss 488.00
Primary Circuit loss type Boiler with uninsulated primary pipework and with cylinder thermostat
Primary circuit loss [kWh/y] 610
8/3/2019 Dwelling Report
9/21
Dwelling Details Report30/11/2011 Page 1 of 14
Output from main water heater [kWh/y] 4802.27
Annual Heat gains from water heating system [kWh/y] 2057.00
8/3/2019 Dwelling Report
10/21
Dwelling Details Report30/11/2011 Page 1 of 14
Solar Water heating
Solar panel manufacturer
Solar panel model
Aperture area of solar collector [m] 0.00 Dedicated storage volume [Litres] 0.00
Zero loss collector efficiency0.00 Solar storage combined? No
Collector heat loss coefficient, 0.00 Total Volume of Cylinder [Litres]
Collector performance ratio [W/mK] 0.00 Effective solar volume 0.00
Annual Solar Radiation [kWh/m] Daily hot water usage 168.92
Overshading factor 0.00 Volume Ratio 0.00
Solar energy available [kWh/y] 0.00 Solar storage volume factor 0.00
Solar to load ratio 0.00 Solar hot water input [kWh/h] 0.00
Utilisation factor 0.00
Is there a cylinder stat? No
Adjusted utilisation factor 0.00
Collector performance factor 0.87
Is solar water heating pump solar powered? No
Electricity consumption of SWH pump [kWh/y] 75.00
8/3/2019 Dwelling Report
11/21
Dwelling Details Report30/11/2011 Page 1 of 14
8/3/2019 Dwelling Report
12/21
Dwelling Details Report30/11/2011 Page 1 of 14
Lighting and Internal Gains
Basic energy consumption for lighting [kWh/my] 9.30 [kWh/y] 1992.06
Percent low energy fixed lighting outlets [%] 25
Annual energy used for lighting [kWh/my] 1673.00
Internal gains from lighting during heating season[kWh/hs]
1280.00
Lighting 219.00
Appliance and cooking 396.96
Water heating 235.00
Occupants 271.00
Mechanical ventilation 0.00
Heat loss to the cold water network -63.00
Net internal gains 1059.00
8/3/2019 Dwelling Report
13/21
Dwelling Details Report30/11/2011 Page 1 of 14
Net Space Heat Demand
Required temperature during heated hours 21
18
Living area percentage 18.07
Required mean internal temperature [C] 18.54
Thermal mass category of dwelling Medium-high
Utilisation factor Intermittent heating
Internal heat capacity of dwelling [per m] 0.32 0.15
Internal heat capacity [MJ/K] 69.00 32.13
Length of one unheated period [h] 8
Unheated periods per week 14
Heat use during heating season [kWh/y] 30063
Heat use for full year [kWh/y] 32225.00
8/3/2019 Dwelling Report
14/21
Dwelling Details Report30/11/2011 Page 1 of 14
Space heat demand details
0.180.99679416 Mean External 6.00Adj Internal
8/3/2019 Dwelling Report
15/21
Dwelling Details Report30/11/2011 Page 1 of 14
Boiler controlled by Electricity consumption Heat gain [W]
Central heating pumps 10
0
10
Gains from fans and pumps associated with spaceheating system
8/3/2019 Dwelling Report
16/21
Dwelling Details Report30/11/2011 Page 1 of 14
U-Value of ground floor [W/mK] 0.00
8/3/2019 Dwelling Report
17/21
Dwelling Details Report30/11/2011 Page 1 of 14
Efficiency of main water heating system [%]
Manufacturer name Turkington Engineering
Model name Eurocal Outdoor - 70/90
Efficiency adjustment factor
Adjusted efficiency of main water heating system [%]
Energy required for main water heater [kWh/y]
Energy required for secondary water heater [kWh/y]
Primary energy
conversion factor
CO2 emission
factor
8/3/2019 Dwelling Report
18/21
Dwelling Details Report30/11/2011 Page 1 of 14
DeliveredEnergy[kWh/y]
Primary energyconversion factor
CO2 emissionContribution [kWh/y]Comment Type
0.00Renewable Thermal
0.00
0.00Renewable Thermal
0.00
Renewable Thermal 0.00
0.00
Do renewable resources meet the main space heating need?
8/3/2019 Dwelling Report
19/21
Dwelling Details Report30/11/2011 Page 1 of 14
Summer internal gains
Dwelling Volume [m] 535.50
Effective air change rate for summer period [ac/h] 2
Ventilation heat loss coefficient [W/K] 353.00
Fabric heat loss coefficient [W/K] 684.00
Heat loss coefficient under summer conditions [W/K] 1037.00
Total Solar Gains for Summer Period 0.00
Internal gains [W] 1059.00
Total gains in summer [W] 1059.00
Temperature increment due to gains [C] 1.00
Summer mean external temperature [C] 15.00
8/3/2019 Dwelling Report
20/21
Dwelling Details Report30/11/2011 Page 1 of 14
0.32Heat capacity parameter
0.00Temperature increment related to thermal mass [C]
16.00
8/3/2019 Dwelling Report
21/21
Dwelling Details Report30/11/2011 Page 1 of 14
Results
Primary energy [kWh/y] CO2 emissions [kg/y]
48739.00 12052.00
0.00 0.00
6488.00 1604.00
0.00 0.00
807.00 192.00
4518.00 1076.00
0.00 0.00
0.00 0.00
60553.00 14924.00
282.69 69.68
Energy Rating D2