DUAL CompactAir cooler – dual discharge, compact

DHFR-404A, R-134a, …50 Hz2 – 15 KW

TECHNICAL DATA

Page 2: DUAL Compact - Leeds | Bristol | TF Solutions€¦ · DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW DHF L2 HFC 1.95 – 9.62 kW: Tray Fin Casing

32 Subject to technical changes. Subject to technical changes.

Blow-through

1 – 4

IP 44: 350 mm

Staggered tube arrange-ment

Fin spacing: 4 mm

Air-flow direction

Fans

Heat exchanger

Suitable applications

Refrigerant/capacity

Available defrosting types

Circulating air Electric Hot gas Brine Water

Coil

Technical details

Available material

Room temperatures above 0 °C Picking areas Corridors Sales rooms

Refrigerant t0 Air inlet Fin spacing4 mm

DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW

DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW

DHF L2 HFC 1.95 – 9.62 kW

Tray Fin Casing Tube

AlMg

Aluminium

Copper

Aluminium, epoxy resin-coated

Standard version

DUAL Compact

DHFAir cooler – dual discharge, compact

2 – 15 kW

Advantages – Flat design – Even air distribution – Low draught air level – Short delivery times with units in stock

Easy mounting – Ceiling mounting brackets with slotted hole for easy installation

– Fans wired to terminal box – Empty tube for defrost sensor – Easily removable side cover – Only one condensation water drain per unit – Schrader valve at outlet

Inspection and cleaning – Hinged tray and heating sheet, drain pipe does not have to be dismantled

HACCP hygiene certificate – All materials used are food-safe – All components are easy to clean – Visual inspection of the entire unit possible – Support bracket flush with upper surface of casing

Heat exchanger – Staggered tube pattern – Internally-ribbed special copper pipes for HFC – Surface-corrugated aluminium fins for high heat exchange

Casing – Corrosion-resistant aluminium alloy AlMg – Powder coating in RAL 9003

High quality tray design – Corrosion-resistant aluminium alloy AlMg – Powder coating in RAL 9003 – Separate drip tray – Thermally decoupled tray (condensation free) – Collection tray for condensation with only one drain

Fans – Tried-and-tested quality fans – 3 fan types for different sound levels – Internal motor protection with thermocontacts – Factory-wired to terminal box – 230 V, 1~, 50 Hz or 60 Hz

Options / Accessories – Epoxy resin-coated fins – Electric defrost heater for coil, wired on connection socket

– Factory-fitted thermostatic expansion valve

Available option

Page 3: DUAL Compact - Leeds | Bristol | TF Solutions€¦ · DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW DHF L2 HFC 1.95 – 9.62 kW: Tray Fin Casing

54

� Aluminium fins � Fin spacing: 4 mm � Tubes staggered in air-flow direction � Special copper tubes: Ø 12 mm � Schrader valve at outlet

The capacity specifications apply to R-404A.The cooling capacity ratings refer to an air inlet temperature differential derived from the difference between the air inlet temperature at the cooler tL1 and the evaporating tempera-ture to, dT1 = tL1 – to.

These conditions are marked with dT1 and comply with the requirements of EN 328 and the Eurovent certification.

Our Güntner Product Calculator design software provides you with a thermodynamic design with capacity specifications compliant with Eurovent. This program provides a safe and easy way of configuring a suitable switch cabinet containing the appropriate control and regulation components.

� Aluminium-magnesium alloy, powder-coated in RAL 9003 (signal white)

� Stainless steel brackets for ceiling mounting flush with upper surface of casing

� Electric defrosting for coils and trays, factory-fitted � Electric defrosting for coils and trays, in set for on-site installation

� Epoxy resin-coated fins

� Aluminium-magnesium alloy, powder-coated in RAL 9003, thermally decoupled, polyamide condensation water drain, G thread with flat sealing compliant with DIN ISO 228-1

� Inner and outer trays hinged and removable for easy cleaning

Quality standard for hygiene certified by TÜV SÜD: The units are easy to clean and are particularly suitable for foodstuff processing applications since they are also approved for all materials used in contact with food.

The operation of units below a cold room temperature of -25 °C requires a special design.

Please contact our Sales team for further information.

� Low-noise axial fans with two preset speed settings, wired as standard

� IP 54 in acc. with DIN 40050 � Temperature range: -30 °C to +40 °C � Protection guard in acc. with EN 294 � Internal motor protection � Thermal class 130 (B) � AC fan, 230 V, 1~, 50 Hz

The second stage of the ErP Directive requiring mandatory minimum efficiency levels for fans came into effect on 1 January 2015. The products affected include products with built-in fans whose optimum input power is higher than 125 W. Conformity with the ErP Directive is explicitly indicated for units designed with the Güntner Product Calculator (GPC).

Capacity

Note

ErP Directive

Cooler coil

Casing

Options

Drip tray

Fans

Subject to technical changes. Subject to technical changes.

DHF | Designs

HACCP

Page 4: DUAL Compact - Leeds | Bristol | TF Solutions€¦ · DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW DHF L2 HFC 1.95 – 9.62 kW: Tray Fin Casing

76

DHF 035A/14-L2 1.9 11.5 1080 750 4 VT037U 0.05 0.20 B

DHF 035A/14-L1 2.2 11.5 1460 900 6 VT037U 0.06 0.27 C

DHF 035A/14-N 2.8 11.5 2290 1380 8 VT038 0.16 0.72 D

DHF 035B/14-L2 2.3 17.3 990 750 4 VT037U 0.05 0.20 B

DHF 035B/14-L1 2.9 17.3 1375 900 6 VT037U 0.06 0.27 B

DHF 035B/14-N 3.8 17.3 2140 1380 8 VT038 0.16 0.72 D

DHF 035A/24-L2 3.8 23.1 2160 750 5 VT037U 0.10 0.20 B

DHF 035A/24-L1 4.5 23.1 2920 900 7 VT037U 0.12 0.27 C

DHF 035A/24-N 5.6 23.1 4580 1380 11 VT038 0.32 0.72 D

DHF 035B/24-L2 4.7 34.6 1980 750 5 VT037U 0.10 0.20 B

DHF 035B/24-L1 5.8 34.6 2750 900 7 VT037U 0.12 0.27 B

DHF 035B/24-N 7.6 34.6 4280 1380 11 VT038 0.32 0.72 D

DHF 035A/34-L2 5.7 34.6 3240 750 5 VT037U 0.14 0.20 B

DHF 035A/34-L1 6.7 34.6 4380 900 7 VT037U 0.19 0.27 C

DHF 035A/34-N 8.6 34.6 6870 1380 11 VT038 0.48 0.72 D

DHF 035B/34-L2 7.0 52.0 2970 750 5 VT037U 0.14 0.20 B

DHF 035B/34-L1 8.67 52.0 4125 900 7 VT037U 0.19 0.27 B

DHF 035B/34-N 11.4 52.0 6420 1380 11 VT038 0.48 0.72 D

DHF 035A/44-L2 7.6 46.2 4320 750 5 VT037U 0.19 0.20 B

DHF 035A/44-L1 8.9 46.2 5840 900 7 VT037U 0.25 0.27 C

DHF 035A/44-N 11.2 46.2 9160 1380 12 VT038 0.64 0.72 D

DHF 035B/44-L2 9.3 69.3 3960 750 5 VT037U 0.19 0.20 B

DHF 035B/44-L1 11.6 69.3 5500 900 7 VT037U 0.25 0.27 B

DHF 035B/44-N 15.2 69.3 8560 1380 12 VT038 0.64 0.72 D

35.6 57 2.8 230V-4x0.35kW dhf1 916 908 270 660 31 16 18

42.6 64 2.8 230V-4x0.35kW dhf1 916 908 270 660 31 16 18

52.6 74 2.8 230V-4x0.35kW dhf1 916 908 270 660 31 16 18

35.6 57 4.1 230V-4x0.35kW dhf1 916 908 270 660 35 16 18

42.6 64 4.1 230V-4x0.35kW dhf1 916 908 270 660 35 16 18 52.6 74 4.1 230V-4x0.35kW dhf1 916 908 270 660 35 16 18

38.4 60 5.3 230V-4x0.65kW dhf2 1516 908 270 1260 56 16 28

45.4 67 5.3 230V-4x0.65kW dhf2 1516 908 270 1260 56 16 28 55.4 77 5.3 230V-4x0.65kW dhf2 1516 908 270 1260 56 16 28

38.4 60 7.6 230V-4x0.65kW dhf2 1516 908 270 1260 67 16 28

45.4 67 7.6 230V-4x0.65kW dhf2 1516 908 270 1260 67 16 28

55.4 77 7.6 230V-4x0.65kW dhf2 1516 908 270 1260 67 16 28

39.9 62 7.3 230V-4x0.65kW dhf3 2116 908 270 1860 81 16 28

46.9 69 7.3 230V-4x0.65kW dhf3 2116 908 270 1860 81 16 28

56.9 79 7.3 230V-4x0.65kW dhf3 2116 908 270 1860 81 16 28

39.9 62 10.8 230V-4x0.65kW dhf3 2116 908 270 1860 91 16 28

46.9 69 10.8 230V-4x0.65kW dhf3 2116 908 270 1860 91 16 28

56.9 79 10.8 230V-4x0.65kW dhf3 2116 908 270 1860 91 16 28

40.9 63 9.6 230V-4x0.8kW dhf5 2716 908 270 1230 106 16 28

47.9 70 9.6 230V-4x0.8kW dhf5 2716 908 270 1230 106 16 28

57.9 80 9.6 230V-4x0.8kW dhf5 2716 908 270 1230 106 16 28

40.9 63 14.0 230V-4x0.8kW dhf5 2716 908 270 1230 130 16 28

47.9 70 14.0 230V-4x0.8kW dhf5 2716 908 270 1230 130 16 28

57.9 80 14.0 230V-4x0.8kW dhf5 2716 908 270 1230 130 16 28

50 HzNumber of fans

Nominal capacity R-404A

Surface Air volume flow

Fan speed Air throw*

Fan type Power consump-tion

Current Energy efficiency class

Fin spacing Defrost SC2 Pel total

DT1 = 8 K to = -8 °C

4 mm electric kW m2 m3/h rpm m kW A

DHF for HFC | Capacity tables

4 mmE

electric

Subject to technical changes. Subject to technical changes.

AC 50 4EC 60 7

HzE

EAmm mmHFCCO2

Fluid

ACSound pressure

Sound power level

Tube volume

mounted el. defrost/Coil and drip tray

Sketch unittype

Dimensions Net weight Connections refrigerant

In stock

El. voltage / Power consumption

L B H E Inlet Outlet

dB(A) 3 m dB(A) l mm mm mm mm kg mm Ø mm Ø

* measurable up to 0.5 m/s

Page 5: DUAL Compact - Leeds | Bristol | TF Solutions€¦ · DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW DHF L2 HFC 1.95 – 9.62 kW: Tray Fin Casing

98

DHF 2 N E4035 A/

DHF | Sketches

Subject to technical changes.

Refrigerant

Fin material

fR SC 2 fR SC 3

fM factor

R-507

Aluminium

R-134a

Aluminium-coated

0.97

0.91

0.97

1

0.85

0.97

Correction factors (fR)for other refrigerantsacc. to Eurovent

Correction factors (fM)for other fin materials acc. to Eurovent

Effective refrigerating capacity Q0 = nominal refrigerating capacity Q0N × correction factor fR

SC2 = standard condition dT1 = 8 K, to = -8 °CSC3 = Standard condition dT1 = 7 K, to = -25 °C

Effective refrigerating capacity Q0 = nominal refrigerating capacity Q0N × correction factor fM

Correction factors acc. to Eurovent

Nomenclature

Model range

Fan with ∅ 350 mm

Coil dimensions

Number of fans Fin pattern : 4 mm

Standard design = N Low noise level design = L

Defrosting:A = Air defrost

E = Electric defrost

Subject to technical changes.

3 mounting brackets (E/2) for: DHF 035 A/44 and DHF 035 B/44

Page 6: DUAL Compact - Leeds | Bristol | TF Solutions€¦ · DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW DHF L2 HFC 1.95 – 9.62 kW: Tray Fin Casing

1110

Page 7: DUAL Compact - Leeds | Bristol | TF Solutions€¦ · DHF N HFC -8 °C 0 °C 2.86 – 15.32 kW DHF L1 HFC -8 °C 0 °C 2.29 – 11.89 kW DHF L2 HFC 1.95 – 9.62 kW: Tray Fin Casing

Güntner GmbH & Co. KGHans-Güntner-Str. 2 – 682256 FürstenfeldbruckGERMANY

www.guentner.de

Members of Güntner Group

Subje

ct to

tech

nical

chan

ges.

KAT1

07.2

/19.

04.2

016