Cold Sequence 200 & 320 amp Specifications • 200 amp – 4, 5 or 7 terminal. • 320 amp continuous – 4, 5 or 7 terminal 600 volt, 10K AIC. • Ringless heavy duty lever bypass meter socket as required by utility. • UL Listed system includes meter socket, disconnect and neutral – installed into one enclosure. • Suitable for use as service equipment only. • Circuit breaker connected ahead of meter for added safety while servicing equipment. • Circuit breaker type rated: 200 amp @ 600V @ 22K, 480V @ 35K, 240V @ 65K AIC. • Disconnects have lockable/sealable safety covers for ON / OFF operation. • Overhead/underground units have upper and lower covers with lock and sealing provisions for utility security. • Overhead/underground units have large hub opening for 3” or 4” hub. Order hubs separately. • Underground units have side-by-side covers with lock and sealing provisions for utility security. • Type 3R enclosure constructed with heavily galvanized G90 steel with light gray polyester powder coat finish. • Convenient concentric knockouts and ample mounting embosses for ease of installation. • Wire terminations accept copper or aluminum conductors. See ordering information for line and load wire sizes. Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. OH/UG SERVICE U5767-X-200-CB 200 AMP UG SERVICE U5797-O-400-CB 320 AMP
3

Cold Sequence · Cold Sequence 200 & 320 amp Specifications • 200 amp – 4, 5 or 7 terminal. • 320 amp continuous – 4, 5 or 7 terminal 600 volt, 10K AIC. • Ringless heavy

Mar 15, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Cold Sequence · Cold Sequence 200 & 320 amp Specifications • 200 amp – 4, 5 or 7 terminal. • 320 amp continuous – 4, 5 or 7 terminal 600 volt, 10K AIC. • Ringless heavy

Cold Sequence 200 & 320 amp

Specifications• 200 amp – 4, 5 or 7 terminal.

• 320 amp continuous – 4, 5 or 7 terminal 600 volt, 10K AIC.

• Ringless heavy duty lever bypass meter socket as required by utility.

• UL Listed system includes meter socket, disconnect and neutral – installed into one enclosure.

• Suitable for use as service equipment only.

• Circuit breaker connected ahead of meter for added safety while servicing equipment.

• Circuit breaker type rated: 200 amp @ 600V @ 22K, 480V @ 35K, 240V @ 65K AIC.

• Disconnects have lockable/sealable safety covers for ON / OFF operation.

• Overhead/underground units have upper and lower covers with lock and sealing provisions for utility security.

• Overhead/underground units have large hub opening for 3” or 4” hub. Order hubs separately.

• Underground units have side-by-side covers with lock and sealing provisions for utility security.

• Type 3R enclosure constructed with heavily galvanized G90 steel with light gray polyester powder coat finish.

• Convenient concentric knockouts and ample mounting embosses for ease of installation.

• Wire terminations accept copper or aluminum conductors. See ordering information for line and load wire sizes.

Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary

by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician

and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

OH/UG SERVICEU5767-X-200-CB200 AMP

UG SERVICEU5797-O-400-CB320 AMP

Page 2: Cold Sequence · Cold Sequence 200 & 320 amp Specifications • 200 amp – 4, 5 or 7 terminal. • 320 amp continuous – 4, 5 or 7 terminal 600 volt, 10K AIC. • Ringless heavy

COLDSEQUENCE 3/17Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

Catalog Number Amp Term System Service Line Load Disconnect AIC Drawing Wt (lbs.)

U5764-X-200-CB 200 4 1Ø3W OH/UG* 1/0-350 kcmil #6-350 200a CB *** Fig A 47

U5764-X-200-5T-CB 200 5 1Ø3W OH/UG* 1/0-350 kcmil #6-350 200a CB *** Fig A 47

U5765-X-200-CB 200 5 3Ø3W OH/UG* 1/0-350 kcmil #6-350 200a CB *** Fig A 52

U5767-X-200-CB 200 7 3Ø4W OH/UG* 1/0-350 kcmil #6-350 200a CB *** Fig A 53

U5784-O-200-CB 200 4 1Ø3W UG 1/0-350 kcmil #6-350 200a CB *** Fig B 64

U5784-O-200-5T-CB 200 5 1Ø3W UG 1/0-350 kcmil #6-350 200a CB *** Fig B 64

U5785-O-200-CB 200 5 3Ø3W UG 1/0-350 kcmil #6-350 200a CB *** Fig B 70

U5787-O-200-CB 200 7 3Ø4W UG 1/0-350 kcmil #6-350 200a CB *** Fig B 71

Catalog Number Amp Term System Service Line Load Disconnect AIC Drawing Wt (lbs.)

U5764-X-200-TF 200 4 1Ø3W OH/UG* 1/0-350 kcmil #6-350 200a TF 200K Fig A 43

U5764-X-200-5T-TF 200 5 1Ø3W OH/UG* 1/0-350 kcmil #6-350 200a TF 200K Fig A 43

U5765-X-200-TF 200 5 3Ø3W OH/UG* 1/0-350 kcmil #6-350 200a TF 200K Fig A 47

U5767-X-200-TF 200 7 3Ø4W OH/UG* 1/0-350 kcmil #6-350 200a TF 200K Fig A 48

U5784-O-200-TF 200 4 1Ø3W UG 1/0-350 kcmil #6-350 200a TF 200K Fig B 61

U5784-O-200-5T-TF 200 5 1Ø3W UG 1/0-350 kcmil #6-350 200a TF 200K Fig B 61

U5785-O-200-TF 200 5 3Ø3W UG 1/0-350 kcmil #6-350 200a TF 200K Fig B 65

U5787-O-200-TF 200 7 3Ø4W UG 1/0-350 kcmil #6-350 200a TF 200K Fig B 66

Catalog Number Amp Term System Service Line Load Disconnect AIC Drawing Wt (lbs.)

U5794-X-400-CB 320 4 1Ø3W OH (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig C 79

U5794-X-400-5T-CB 320 5 1Ø3W OH (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig C 79

U5795-X-400-CB 320 5 3Ø3W OH (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig C 83

U5796-X-400-CB 320 7 3Ø4W OH (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig C 86

U5797-O-400-CB 320 4 1Ø3W UG (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig D 101

U5797-O-400-5T-CB 320 5 1Ø3W UG (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig D 101

U5798-O-400-CB 320 5 3Ø3W UG (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig D 108

U5799-O-400-CB 320 7 3Ø4W UG (2) 3/0-500 kcmil (2) 3/0-500 kcmil 400a CB 10K Fig D 110

200 Amp Circuit Breaker Disconnect Ahead Of Meter Socket

200 Amp T-Fuse Pullout Disconnect Ahead Of Meter Socket

400 Amp (320 Amp Continuous) Circuit Breaker Disconnect Ahead Of Meter Socket

Cold Sequence 200 & 320 amp

Barrel lock provision on meter panel available. Add -BL suffix to end of catalog number.* UL Listed for overhead and underground use. Consult utility for underground use acceptance.** Outline drawings and knockout information are located on back page.*** Circuit breaker type rated: 600V @ 22K, 480V @ 35K, 240V @ 65K AIC.

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary

by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician

and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.

Page 3: Cold Sequence · Cold Sequence 200 & 320 amp Specifications • 200 amp – 4, 5 or 7 terminal. • 320 amp continuous – 4, 5 or 7 terminal 600 volt, 10K AIC. • Ringless heavy

COLDSEQUENCE 3/17Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com

1.13

1.13

56.00

35.50

00.100.1

13.00 O.D.6.50

C (4)

A (5)

6.01 I.D.

3.75

2.74

.69

1.942.77

2.25 2.44

4.50 4.50

B (1)BB (1)

D (2)

1.13

2.78

13.00 O.D.

1.00 1.006.50

1.13

43.00

33.00

C (6)A (5)

4.06 4.06

2.00 2.03.76

2.19

B (1)BB (1)

2.06

4.84 I.D.

2.78

1.13

11.13

28.00

1.13

1.00

6.41

19.59

26.00 O.D.

1.00

A (4)2.06

4.84 I.D.

BB (2)

2.88

2.44

2.25 2.44

.69

2.19

6.59 6.59

2.25

4.50 4.50 4.50 4.50

1.94B (2)

BB (2)C (6)D (4)

NOT

KO CONFIGURATIONSAU L MTG. EMBOSSB0 .25” 0.5” CONC.C1 .25” 1.5” 2” 2.5” 3” CONC.D1 .25” 1.5” 2” 2.5” CONC.BB 0 .25” SOLID

KO CONFIGURATIONSAU L MTG. EMBOSSB0 .25” 0.5” CONC.C1 .25” 1.5” 2” 2.5” 3” CONC.BB 0 .25” SOLID

KO CONFIGURATIONSAU L MTG. EMBOSSB0 .25” 0.5” CONC.C1 .25” 1.5” 2” 2.5” 3” CONC.BB 0 .25” SOLID

1.13

36.00

1.13

00.100.1

26.00 O.D.

15.50

6.4119.59

A (4)

6.00 I.D.

2.74

.687 2.444.50

2.254.50

4.50

2.25 2.444.50

1.942.77

C (6)

B (2)

BB (2)

D (4)

3.750

KO CONFIGURATIONSAU L MTG. EMBOSSB0 .25” 0.5” CONC.C1 .25” 1.5” 2” 2.5” 3” CONC.D1 .25” 1.5” 2” 2.5” CONC.BB 0 .25” SOLID

FIG. A – 200 AMP OH/UG (U5764)F IG. B – 200 AMP UG (U5784)

FIG. C – 320 AMP OH (U5794)F IG. D – 320 AMP UG (U5797)

Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary

by utility, and may require local electrical inspector approval. All installations must be installed by a licensed electrician

and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in

specifications and features shown without notice or obligation.