  • was born in 1987 with the purposeto manufacture ventilation systems. Theengagement of the founders has allowed to gobeyond creating a line of components that havebecome very soonthe main activity.From 2001 a newpar tnersh ip hasbrought energies,enthusiasm and deepknowledge of thesector, practically awave of modernity. From the 2010 the companyis operating into an indoor area of 5.000 sqmeters and it is more and more establishedin the national and international market.

    is today a specialized productivereality in the industrial ventilation and it hasdeveloped a range of fans for all the ventilationapplications, with particular experience in thesectors of conditioning, sound-proofing, drying,refrigeration in industrial, commercial,zootechnical, naval, rail road applications etc.The quality of our equipments, together with theprofessionality of our staff, concurs to executespecial constructions on specific demand.

    Idee, capacit e mezzi per fare bene...... I ventilatoriIdeas, and ability means to make fans... well

    Dal passato al presenteFrom the past to the present

    nata nel 1987 con lo scopo di

    realizzare impianti di aspirazione. Limpegno dei

    fondatori ha permesso di andare oltre creando

    una linea di componenti che sono diventati ben

    presto la parte preponderante dellattivit. Dal

    2001 il nuovo assetto societario ha portato energie,

    entusiasmo e profonda conoscenza del settore,

    in pratica una ventata di modernit, a tal puntoche dal 2010 lazienda opera in un area chesupera i 5.000 mq coperti ed diventata unapresenza affermata nei mercati nazionali einternazionali.

    L oggi una realt produttiva

    specializzata nella ventilazione industriale ed ha

    sviluppato una gamma di ventilatori per tutte le

    applicazioni aerauliche, con particolare esperienza

    n e i s e t t o r i d e l c o n d i z i o n a m e n t o ,

    dellinsonorizzazione, dellessicazione, della

    refrigerazione in applicazioni di tipo industriale,

    commerciale, zootecnico, navale, ferroviario ecc.

    La qualit delle nostre attrezzature, unita alla

    professionalit del nostro personale, consente di

    eseguire costruzioni speciali su specifica richiesta.

  • Eseguiamo in prima persona le fasi del ciclo

    produttivo: progettazione, costruzione, assem-

    blaggio e collaudo dei componenti principali

    dei nostri ventilatori, soprattutto delle giranti,

    di cui curiamo in particolare la bilanciatura, e

    dei convogliatori: tagliando, forando, defor-

    mando, piegando e saldando le lamiere con

    macchinari efficienti e personale specializzato.

    We carry out in person all the phases of the

    productive cycle: design, manufacturing, as-

    sembly and test of the main components of

    our fans, in particular we take care of the

    balancing of the impellers and about conveyors

    by cutting, drilling, bending and welding the

    metal sheets with our efficient machinery and

    specialized staff.

    Come lavoriamoHow we work

    I nostri ventilatori sono conformi alla direttiva 2006/42/CEe possono essere marchiati:Our fans conforms to directive 2006/42/EC and shall bemarked:

    I nostri venti latori possono essere marchiati :Our fans shall be marked:

    I nostri ventilatori per estrazione fumi di incendio sono statitestati con esito positivo e omologati dallente autorizzato:Our smoke exhaust fans have been positively tested andapproved by the authorised body.

    Ai nostri prodotti ATEX possiamo apporre il marchio:Our ATEX products are marked:

  • Il nostro programma di produzione comprende:-ventilatori elicoidali da parete a pannello con motoria velocit regolabile e limitati ingombri oppure contradizionali motori elettrici unificati;-ventilatori elicoidali ad anello ed intubati, con girantea profilo alare ad alto rendimento, di diametro da 250a 1400 mm ed oltre;-destratificatori per ambienti industriali completi diregolatori manuali ed automatici;-ventilatori per alte temperature per estrazione fumidincendio omologati per funzionamento a 600C/120-400C/120-200C/120 ecc.., secondo la normaeuropea EN 12101-3- ventilatori antideflagranti per utilizzo in aree pericolosesecondo la normativa europea ATEX 94/9/CE (II 2Go II 3G).-torrini capaci di estrarre od immettere elevate portatedaria con ridotta rumorosit;- una serie di componenti quali giranti e convogliatori,realizzati con i materiali pi adatti alle diverse situazioni(alluminio, tecnopolimero, acciaio inox, lamieraverniciata, ecc.).- una gamma di ventilatori in linea, centrifughi,cassonati, recuperatori di calore, di regolatori divelocit e di accessori in continuo incremento edevoluzione.

    Our program includes:- plate mounted axial fans with speed adjustablecompact motors or with traditional UNEL-MEC/IECelectric motors;- ring and ducted axial fans, with high efficiency airfoilimpeller, diameter from 250 up to 1400 mm and over;- scatters for industrial environments including manualand automatic regulators;- high temperature fans for smoke extraction certifiedfor working at 600C/120-400C/120-200C/120 etc.according to EN 12101-3;- explosion proof fans for installation in hazardousareas according to the European ATEX directive94/9/CE (II 2G or II 3G);- roof fans to extract or intake large volumes of airwith low noise level;- a series of components as impellers and conveyors,manufactured with materials suitable for the differentsituations (aluminum, techno-polymer, stainless steel,painted steel, etc.).- a range of centrifugal fans, cabinet fans speedregulators and accessories in continuos development...

    Ventilatori s ... ma quali? Fans yes... But which ones?

  • Programma di selezione/Selection program

  • Dall'idea alla Pratica - From the Idea to the PracticeGrazie alla flessibilit produttiva, alla costante ricercae innovazione tecnologica, la gamma di ventilatoriElektrovent soddisfa le richieste di un mercato incontinua evoluzione.In quest'ottica il nostro Ufficio Tecnico Commerciale in grado di affiancare la nostra clientela nella sceltadel prodotto o sistema di ventilazione pi idoneoproponendo soluzioni personalizzate e tecnicamenteaffidabili.Per fornire questo servizio ci avvaliamodell'esperienza maturata nel settore, del costantesupporto dell'Ufficio Tecnico e del riscontro derivantedall'utilizzo di Software CFD (Computational FluidDynamics).Un software CFD in grado di simulare e determinaretutte le variabili fluido-dinamiche di un'impianto diventilazione o di un ventilatore nelle condizioni dilavoro impostate.L'analisi parte da un modello matematico 3D nelquale vengono inseriti i parametri caratteristici delsistema (aeraulici, termici, transitori) e i materialiche caratterizzano il progetto.

    L'analisi tramite software CFD richiesta soprattuttonel campo della ventilazione dei parcheggi interrati,in quanto questa applicazione si basa sulladistribuzione lungo tutta la superficie del parcheggiodi una serie di acceleratori assiali o centrifughi (serieJP-DUCT e JP-CENTRY) i quali hanno un duplicecompito: creare un flusso d'aria a livello del terrenoche prelevi l'aria dall'esterno e la indirizzi verso iventilatori stessi, mentre a livello del soffitto il flussod'aria viene spinto di acceleratore in acceleratoreverso i punti d'espulsione, eliminando l'installazionedelle canalizzazioni.

    Thanks to the productive flexibility, constant researchand technological innovation, the Elektrovent line offans fulfills all requirements of a market in continuousevolution.From this perspective our Technical CommercialOffice is able to assist our customers on selecting themost suitable product or system, proposing customizedand technically reliable solutions.The quality of our service is guaranteed by theexperience matured in the sector, the constant supportof the Technical Office and the acknowledgmentresulting from the use of the CFD software(Computational Fluid Dynamics). CFD is able tosimulate and determine all the fluid-dynamic variablesof a ventilation system or a fan in the conditions ofwork set.Analysis proceeds from a 3D mathematical modelwhere the specific parameters of the system (air,temperature, transitions) and materials featuring theproject are entered.

    CFD analysis is mainly required in the undergroundcar parks ventilation based on a distribution of a seriesof axial or centrifugal impulse fans (JP-DUCT or JP-CENTRY) having the double duty to create an airflowin the ground level to intake the air from outside andconvey it to the fans; while on the ceiling, the airflowis threw fan by fan and lead to the discharge points,avoiding the installation of ducting.

  • In utilizziamo questo tipo di analisi, non

    solo per agevolare la fase di progettazione, ma anche

    per verificare le differenti soluzioni proposte. I parametri

    che possono essere valutati sono molteplici, ad

    esempio: velocit dell'aria, pressione statica,

    tempera tura , d iss ipaz ione te rmica ,ecc . .

    svolge un'incessante attivit di sviluppo

    del prodotto utilizzando il software CFD anche per la

    progettazione delle nostre giranti (siano esse assiali

    o centrifughe).

    In we use this type of analysis not onlyto facilitate the design stage, but also to check thedifferent solutions offered. Parameters to beconsidered are for example: air speed, static pressure,temperature, thermal dissipation, etc.

    plays an incessant activity ofdevelopment of the product using the CFD softwarealso for the design of our impellers (both axial orcentrifugal).

  • 42

    1 3Alcune regole e formule relative ai ventilatori

    Altre formule:

    Hst = Ht HdHst= Pressione staticaHt= Pressione totaleHd= Pressione dinamica

    Q (m3/h)Hd (mmH2o) = S (m2) x 3600

    16,08

    N (kW) = Q (m3/h) x Ht (mmH2o)102 x 3600 x

    = rendimento

    m3/h = Nm3/h x (273+t x 760)273 Pb

    Pb = Pressione barometricaNm3/h = Normal metri cubi

    n (giri motore)= 120 x frequenza (Hz)numero poli motore

    Variazione del numero di giri per lo stessoventilatore ed a densit costante:

    Variazione dei diametri di giranti (simili) avelocit costante:

    Variazione della densit a numero di giricostanti:

    Q2 = Q1 x n2n1

    H2 = H1 x n2 2 n1

    N2 = N1 x n2 3 n1

    ( )( )( )

    H2 = H1 x y2 y1

    N2 = N1 x y2 y1

    ( )( )

    )

    2

    Portata (Q)Volume daria da espellere o da introdurrein un locale in un periodo di tempo dato.Viene espressa di solito in m3/h o in m3/s.Per calcolare la portata possono venireutilizzati diversi metodi:

    1 In base al volume del locale ed al numerodei ricambi allora necessari a secondadelluso cui viene adibito il locale:

    AMBITO INDUSTRIALE RICAMBI / hAmbienti nocivi 30 - 60Deposito merci 3 6Fonderie 20 30Lavanderie industriali 15 30Sala macchine 20 30Stabilimenti (in genere) 8 10Stabilimenti con forni 30 60Officine meccaniche 5 10Cabine di verniciatura 30 60Officine di saldatura 15 30Tintorie 20 30

    AMBITO COMMERCIALE RICAMBI / hAule scolastiche 2 4Banche 3 4Bar-caff 10 12Biblioteche 3 5Cinema-teatro 10 15Cucine industriali 15 30Mense 5 10Studi di registrazione 10 12Autorimesse 6 8Palestre 6 12Ospedali 4 6Toilette pubbliche 8 15Lavanderie 15 30Uffici 4 8Panetterie 20 30Ristorante 5 10Sale da ballo 6 8Sale conferenze 8 12Parrucchieri 10 15Sale riunioni 4 8

    Questi valori sono indicativi e non debbono maisostituire quelli regolamentari e possono esseremodificati in funzione di particolari esigenze.

    2 A seconda della quantit di personepresenti abitualmente nel locale e delle loroattivit:

    20 -40 m3/h per persona in caso di attivitnormale.108 m3/h per persona nei casi in cui siapermesso fumare.45 m3/h per persona in caso di lavoro fisicoleggero.60 m3/h per persona in officine ed altri locali.

    3 In funzione delle velocit dellariaoccorrenti per la cattura di particelle o dellavelocit di trasporto delle stesse neicondotti.

    VELOCITA DI CAPTAZIONE m/sCappa cucina:- applicazione domestica da 0,20 a 0,3- applicazione commerciale da 0,20 a 0,5Vasche da evaporazione: da 0,25 a 0,5Sgrassaggio: da 0,25 a 0,5Saldatura, decapaggio da 0,50 a 2Galvanizzazione da 0,50 a 1Cabina di verniciatura da 0,40 a 1Smerigliatura, rettifica da 2,50 a 10

    VELOCITA DI TRASPORTO m/sPolvere: 10Farina: 15Segatura: 15Polvere metallica fine: 15Trucioli di legno: 18Trucioli metallici: da 20 a 25

    Per calcolare la portata bisogna moltiplicarequesta velocit (v) per la sezione (S) dipassaggio dellaria:Q (m3/h) = v (m/s) x S (m2) x 3600

    4 - In funzione alla quantit di calore ineccesso da asportare:

    In generale per il raffrescamento di ambientiil volume daria da estrarre dato dalla formulaseguente:Q (m3/h) = Numero kcal/h (*) 0,3 x (Ta Te)

    In cui 1000 watt = 1 kW = 860 kcal

    Ta= Temperatura ambiente (C)Te=Temperatura ar ia esterna (C)(*)= quantit di calore da asportare(vedi tabella 1)

    Tabella 1 Rendimento macchine elettricheRendimento Dispersione di caloreMotori elettrici 70-95% Dal 5 al 30%Trasformatori 90-95% Dal 5 al 10%Raddrizzatori 80-97% Dal 3 al 20%Alternatori 87-98% Dal 2 al 23%

    Leggi dei ventilatoriLe curve caratteristiche dei ventilatoririspondono a certe leggi, denominate leggidei ventilatori, che permettono di determinarele variazioni della portata (Q), della pressione(H) e della potenza assorbita (N) dalla ventola,in presenza di variazioni delle condizioni difunzionamento numero di giri (n) o densitdellaria convogliata (y) o delle dimensioni.(Diametro della ventola D).

    Q2 = Q1 x D2D1

    H2 = H1 x D2 2 D1

    N2 = N1 x D2 5 D1

    ( )( )( )

    3

  • 3Some information, rules and formulas related to the fans

    4

    2

    1Q2 = Q1 x n2

    n1

    H2 = H1 x n2 2 n1

    N2 = N1 x n2 3 n1

    ( )( )( )

    Q2 = Q1 x D2D1

    H2 = H1 x D2 2 D1

    N2 = N1 x D2 5 D1

    ( )( )

    ( )

    H2 = H1 x y2 y1

    N2 = N1 x y2 y1

    ( )( )

    )

    2

    3

    Airflow (Q)Volume of air to be exhausted or introducedin a place in a period of given time. It isusually expressed in m3/h or m3/s.In Italy to calculate the airflow there aresome different ways:

    1) According to the volume of the place andthe number of the required air exchangesper hour in relation with the use in the room:

    INDUSTRIAL ENVIRONMENT EXCHANGES / hHarmful environments 30 - 60Stock House 3 6Foundry 20 30Industrial laundry 15 30Machines room 20 30Workshop (in general) 8 10Workshop with ovens 30 60Mechanization workshop 5 10Painting workshop 30 60Welding workshop 15 30Dry-cleaners 20 30

    COMMERCIAL ENVIRONMENT EXCHANGES / hClassroom 2 4Bank 3 4Caf 10 12Library 3 5Cine-theatre 10 15Industrial Kitchen 15 30Cafeterias 5 10Recording Studio 10 12Garage 6 8Gym 6 12Hospital 4-6Public toilet 8 15Laundry 15 30Offices 4 8Bakery 20 30Restaurant 5 10Ballroom 6 8Conference rooms 8 12Hairdresser 10 15Meeting rooms 4 8

    These values are indicative and they neverhave to replace the normative figures and theycan be modify according to specialrequirements.

    2) According to the quantity of peoplehabitually present in the place and theiractivities:

    20 -40 m3/h per person in case of normalactivity.108 m3/h per person in case that smoke isallowed.45 m3/h per person in case of light physicalactivity.60 m3/h per person in workshops and otherrooms.

    3) According to the air velocities requiredfor the capture of particles or the velocityof transport of the same in the ducts.

    VELOCITY OF CAPTATION m/sKitchen hoods:- domestic application 0,2 to 0,3- commercial application 0,2 to 0,5Evaporation vats: 0,25 to 0,5Degreasing: 0,25 to 0,5Welding, pickling 0,50 to 2Galvanization 0,50 to 1Painting boot 0,40 to 1Grinding , rectification 2,50 to 10

    VELOCITY OF TRANSPORT m/sDust: 10Flour: 15Sawdust: 15Thin metallic dust: 15Wooden shavings: 18Metallic shavings: 20 to 25

    To calculate the airflow multiply this speed (v)for the air crossing section (S):Q (m3/h) = v (m/s) x S (m2) x 3600

    4) In function of the quantity of exceedingheat to be removed:

    In general for the refreshing of environmentsthe airflow to be exhaust is given by the followingformula:Q (m3/h) = Number kcal/h (*) 0,3 (Ta Te)

    Where 1000 watt = 1 kW = 860 kcal

    Ta = Ambient temperature (C)Te = External temperature (C)(*) = Quantity of heat to be removed (see table1)

    Table 1 Efficiency electrical machinesEfficiency Heat dispersionElectric Motors 70-95% 5 to 30%Transformers 90-95% 5 to 10%Rectifiers 80-97% 3 to 20%Alternators 87-98% 2 to 23%

    Fan lawsThe characteristic curves of fans respond tocertain laws, denominated fan laws, thatallow to determine the variation of airflow(Q), pressure (H) and the absorbed powerby the impeller (N), in presence of thevariation of the working conditions, RPM (n)or density of the handled air (y) or dimensions(Diameter of the impeller D).

    Variation of RPM for the same fan atconstant density:

    Variation of fan diameters (similar) atconstant speed:

    Variation of density at constant RPM:

    Other formulas:

    Hst = Ht Hd Hst= Static pressure Ht= Total pressure Hd= Dynamic pressure

    Q (m3/h) Hd (mmH2o) = S (m2) x 3600

    16,08

    N (kW) = Q (m3/h) x Ht (mmH2o)102 x 3600 x

    = efficency

    m3/h = Nm3/h x (273+t x 760)273 Pb

    Pb = Barometric pressure Nm3/h = Normal cubic meters

    n (RPM)= 120 x frequency (Hz) number of poles motor

  • Simbolo dellunit nome dellunit Pa kp/m2 atm TorrSymbol of the unit unit of measure =N/m3 bar mbar =mm H2o mm Hg1 Pa = N/m2 Pascal 1 0.00001 0.01 0,10197 - 0.00751 bar Bar 100000 1 1000 10197.2 0.98692 750.0621 m bar Millibar 100 0.001 1 10.197 0.000987 0.750kgf/m2=mm H2O millimetro colonna dacqua 9.80665 - 0.09807 1 - 0.07356

    millimeter of water gage1 atm 1 atmosfera fisica 101325 1.01325 1013.25 10332.3 1 760

    phisic athmosphere1 Torr = mmHg millimetro colonna di mercurio 133.322 0.00133 1.3332 13.5951 0.00132 1

    millimeter mercury gage

    Fattore K di correzione per la determinazione del peso specifico in condizioni diverse da quelle di riferimento (15C, 760mm Hg = Livello del mare)K correcting factor to define the air density in conditions differing from those of reference (15C, 760mm Hg = Sea level).

    Al variare della temperatura e dellaltitudine variano:- il peso specifico dellaria- la pressione fornita dal ventilatore- la potenza assorbita dalla girante

    Moltiplicare il fattore K trovato con il presente graficoper definire le effettive condizioni di funzionamento.

    According to the variation of the temperature andaltitude vary:- specific weight of the air- pressure of the fan- impeller absorbed power

    Multiply the K factor found in the present graph todefine the real working conditions.

    Unit Portata - Airflow unitsSimbolo dellunit nome dellunit ft3/s ft3/sSymbol of the unit unit of measure m3/s m3/min m3/h l/s cu.ft/s cu.ft/min

    1 m3/s metro cubo/sec. 1 60 3600 1000 35.31 2118.81 m3/min metro cubo/min. 0.01667 1 60 16.667 0.5885 35.311 m3/h metro cubo/ora 2.778x10-4 0.01667 1 0.2778 9.808x10-3 0.58851 l/s = 1 dm3/s litro/sec. 0.001 0.05999 3.6 1 3.531x10-4 2.11881 cu.ft/s (cfs) piede cubo/sec. 2.832x10-2 1.6992 102 28.3179 1 601 cu.ft/min (cfm) piede cubo/min 4.179x10-4 2.832x10-2 1.70 0.47197 1.667x10-2 1

    Unit delle pressioni- pressure units

    Altre formule e unit di misuraOther formulas and units of measure

    Altidudine Press. barometriacaAltitude Barometric press

    mt. mm Hg0 760

    500 7161000 6741500 6352000 5972500 5613000 5263500 4944000 4634500 433

    600

    550

    500

    450

    400

    350

    300

    250

    200

    150

    100

    50

    15

    0

    -500.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3

    Fattore K di correzione - correcting factor k

    760 mm Hg

    710

    660

    610

    560

    510

    460

    410

    tem

    pe

    ratu

    re i

    n

    C

  • DUCT-Mpag. 40

    DUCT-Spag. 49

    DUCT-SOpag. 53

    DUCT-BDpag. 55

    SILENT BOXpag. 99

    Ventilatori elicoidalia pannello Plate mounted axial fans

    Ventilatori assialiad anello Ring axial fans

    Ventilatori assialiintubatiDucted axial fans

    Torrini assiali Axial roof fans

    DestratificatoreelicoidaleAxial scatter

    Torrini centrifughiCentrifugal roof fans

    Ventilatori centrifughiin lineaIn line centrifugal fans

    PLATE-Spag. 18

    Ventilatori cassonatiCabinet fans

    PLATE-Mpag. 22

    RING-drpag. 28

    RING-srpag. 28

    DUCT-BFCpag. 57

    ROOF-AMpag. 66

    ROOF-AVEpag. 71

    DIFFUSERpag. 74

    ROOF-CMpag. 78

    ROOF-CMVpag. 81

    ROOF-CERpag. 86

    KAMINpag. 88

    DIAMpag. 92

    RECTApag. 95

    DC-BOXpag. 104

    BDs-BOXpag. 107

    BD-BOXpag. 109

    Indi

    ce/In

    dex

  • Ventilatori per fumidincendioSmoke exhaust fans

    RegolatoriSpeed regulator

    VentilatoriAntideflagrantiFlame-proof fans

    Ventilatore inmateriale plasticoFan in plastic material

    Recuperatore di caloreHeat recovery unit

    Ventilatori centrifughipale rovesceCentrifugal backwardcurved blade fans

    Ventilatori centrifughipale avantiCentrifugal forwardcurved blade fans

    PLASTICpag. 114

    ECOMpag. 118

    FORWARDpag. 126

    SIROCCOpag. 129

    SI-BACK Apag. 134

    SI-BACK Bpag. 146

    SI-BACK Cpag. 158

    PLATE-Matex

    pag. 168

    RINGatex

    pag. 170

    DUCT-Matex

    pag. 173

    ROOF-AMatex

    pag. 176

    ROOF-CMatex

    pag. 178

    FORWARDatex

    pag. 181

    SIROCCOatex

    pag. 184

    SI-BACKatex

    pag. 185

    DUCT -M htpag. 188

    JP - DUCTpag. 193

    JP - CENTRYpag. 197

    ROOF-HPpag. 205

    SREpag. 218

    SRSpag. 219

    QEApag. 221

    FRCpag. 222

    Indice/Index

    BOX-HTpag. 211

    ROOF-CMV-HTpag. 201