Top Banner
AZURA® instruments & components for (U)HPLC, Prep LC, FPLC and osmometry Product Selection Guide 2017/2018 KNAUER Wissenschaftliche Geräte GmbH · Hegauer Weg 38 · 14163 Berlin · www.knauer.net Made in Germany
80

AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

Feb 06, 2018

Download

Documents

nguyenque
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

AZURA® instruments & components for (U)HPLC, Prep LC, FPLC and osmometry

Product Selection Guide 2017/2018

KNAUER Wissenschaftliche Geräte GmbH · Hegauer Weg 38 · 14163 Berlin · www.knauer.net

Made in Germany

Page 2: AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

Welcome to KNAUER - manufacturer of liquid chromatography instruments and solutions! KNAUER ("KNAUER Wissenschaftliche Geräte GmbH") is an owner-managed middle-sized company situated in Berlin, Germany.  Since 1962, we have been developing, manufacturing and distributing laboratory instruments around the world. With more than 120 employees we are the oldest German manufacturer of instruments for HPLC, FPLC, simulated moving bed chromatography (SMB) and osmometry. Our product portfolio ranges from most compact analytical HPLC systems to SMB systems for the extraction of up to 1.000 kg of pure substance per year. Products and services offered include state of the art HPLC/UHPLC systems, FPLC systems, solutions for the purification of value products and fine chemicals, LC columns, and method development.

The source of our success are numerous world’s firsts that have won more than 20 awards for innovation. We strive to grow continuously, to expand our expertises and to discover new market opportunities.

Quality and environmental management The KNAUER quality management system according to DIN EN ISO 9001 makes sure that we continuously produce products in the best quality possible. As a company, we have to prove ourselves every day in a highly competitive market. Therefore, we can only be successful if every employee contributes his share. Your satisfaction with the quality of our products and services is the key to our success. In addition to our quality management system, KNAUER contributes to the conservation of a healthy environment by basing our work on an environmental management system according to DIN EN ISO 14001.  Starting with the development of a new product, our designing engineers are bound to use long-lasting materials which allow low maintenance time intervals and minimal downtime. Furthermore, a high

energy efficiency and material efficiency in the production process and during the use of our products are important to us. Finally, the products should be able to be disposed of in an environmentally compatible way. Every single part and original spare part corresponds to our strict criteria for construction, material and safety. This is guaranteed by our quality assurance system. And if your products need replacement or repair, it will be as good as a new with original spare parts from KNAUER. The quality management system and the working procedures that come with it are being updated on a regular basis. All KNAUER employees know the procedures of the quality management system and its implementation. Continuous improvement is one of our goals and overall basic management principles.

Your remarks and suggestions are a substantial part of our daily work. They help us become even more precise, faster and more customer friendly. Please let us know what your suggestions are and what we can do better.

Please do not hesitate to contact our quality management team at [email protected]!

Science Together

Alexandra Knauer (CEO and owner)

KNAUER among Top 100 innovators. 

Page 3: AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

Table of contents

(U)HPLC pump AZURA® Pump P 6.1L 1 AZURA® Pump P 6.1L with 5 ml pump head 2 AZURA® Pump P 6.1L with 10 ml pump head 2 AZURA® Pump P 6.1L semi-prep 3 AZURA® Pump P 6.1L metal-free 3

Preparative HPLC pump AZURA® Pump P 2.1L 4

Compact HPLC pumps AZURA® Pump P 4.1S 5 AZURA® Pump P 2.1S 6

Assistant AZURA® Assistant ASM 2.1L 7

Autosampler AZURA® Autosampler AS 6.1L 9

Column thermostat AZURA® Column Thermostat CT 2.1 11

Diode array detectors AZURA® Detector DAD 6.1L 12 AZURA® Detector DAD 2.1L & MWD 2.1L 13

UV/VIS detectors AZURA® Detector UVD 2.1L 14 BlueShadow UV/VIS Detector 50D 15 AZURA® Detector UVD 2.1S 16

Refractive index detector AZURA® Detector RID 2.1L 17

Fluorescence detector Fluorescence Detector RF-20/Axs 18

Light scattering detector Light Scattering Detector Sedex LC/85LT/90LT 19

Electrochemical detector Electrochemical Detector DECADE Elite SCC 20

Conductivity detector Conductivity detector CDD-10 Avp 21

Conductivity/pH monitor AZURA® Conductivity Monitor CM 2.1S 22

Fraction collectors Foxy® R1 and Foxy® R2 23 LABOCOL Vario-4000 25

Electrical valves AZURA® Valve Drive V 2.1S Multiposition 26 Electric valves for many injection and/or switching tasks 27

Manual valves Manual injection and multi-position switching valves 28

Page 4: AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�1

Table of contents

Ultra high-pressure valves 2-position and multi-position valve 29

Online degasser AZURA® Degasser DG 2.1S 30

Osmometer K-7400S Semi-Micro Osmometer 31

Software Mobile Control (Chrom) for Windows 10 32 ClarityChrom® 33 PurityChrom® 34 OpenLAB® CDS EZChrom Edition 35 Thermo Scientific™ Dionex™ Chromeleon™ chromatography data system driver 36

PC hardware & IT accessories / power connections PC German 37 PC international 37 PC special edition 37 Network devices 37 IT accessories 37 Power connections 37

Column kits RP column kit 38 NP column kit 38 Mixed column kit 38 GPC column kit 38 SEC column kit 38

Pump accessories Eluent tray and bottles 39 Solvent filters and pump inlet tubing 39 Static mixers 39 Dynamic mixers 39 Pump head inlet fittings 40 Pump head outlet fittings 40 Mass flow controllers 40 Replacement pump head AZURA® Pump P 4.1S & P 2.1S 41 Replacement pump head AZURA® Pump P 6.1L 41 Replacement pump head BlueShadow 40P 41 Replacement pump head AZURA® Pump P 2.1L / Blue Shadow 80P 41 Check valves 41 Maintenance kits 42

Autosampler accessories AZURA® Autosampler AS 6.1L 42

Detector accessories Flow cells 1/16“ 43 Flow cells 1/8“ 43 Flow cells 1/4“ 43 Flow cells 1/16“ fiber optics 43 Flow cells 1/8“ fiber optics 43 Nano flow cell 43 Flow cells >1/8“ fiber optics 44 Fiber optic cables 44 Waste tubing kits 44 Lamps 44

Page 5: AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�2

Table of contents

Valve accessories Valve head 1/16“ stainless steel 45 Valve head 1/8“ stainless steel 45 Valve head 1/16“ PEEK 45 Valve head 1/8“ PEEK 45 Rotor seals 45 Sample loop stainless steel, 1/16“ 46 Sample loop stainless steel, 1/8“ 46 Sample loop PEEK, 1/16“ 46 Sample loop PEEK, 1/8" 46 Injection syringes 47 Luer-Lock glass syringes 47 Loop filling ports 47 AZURA® mounting brackets 47

Services / Qualification Installation Qualification (IQ) - scope of delivery with all AZURA® instruments 48 Installation Qualification (IQ) - software 48 Operation Qualification (OQ) - pumps 48 Operation Qualification (OQ) - autosampler 48 Operation Qualification (OQ) - detectors 48 Operation Qualification (OQ) - flow cells 48 Operation Qualification (OQ) - osmometer 48 Operation Qualification (OQ) - valves 48 Operation Qualification (OQ) - fraction collectors 48 Operation Qualification (OQ) - column thermostat 48 Performance Verification (PV) 48

Accessories – Fittings K-Connect system - Kits consisting of bushings, clamping and sealing rings 49 DYNASEAL system - Kits consisting of bushings, clamping and sealing rings 49 Bushings for capillaries - DYNASEAL 49 Split-grooved clamping rings 49 Sealing rings 49 Biconical sealing rings 49 Bushings for capillaries, 1/16“, stainless steel 50 Bushings for capillaries, 1/8“, stainless steel 50 Ferrules for capillaries 50 Bushings for capillaries, 1/16"/1/8", PEEK & polymer 50 Flat bottom fittings and adapters 50

Accessories – Caps/connectors Caps (blind fittings) 51 Low dead volume unions, polymer/PEEK 51 Low dead volume unions, stainless steel /titanium 51 Unions and reducing unions, stainless steel 51 T-connectors, stainless steel/titanium 52 T-connectors, polymer 52 X-connectors, stainless steel 52 X-connectors, polymer 52 Pressure release valves 52 Backpressure regulators 52

Accessories - Capillaries Capillaries, stainless steel, 1/16" 53 Capillaries, titanium, 1/16" 53 Capillaries, stainless steel, 1/8" 53 AZURA® Analytical K-Connect Start-up Kits, stainless steel, 1/32" capillaries with fitting sleeves for 1/16"connections: Set of precut capillaries, connections, adapters and low dead volume couplings 53

Page 6: AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�3

Table of contents

Accessories - Capillaries Capillaries, AZURA® Analytical K-Connect, stainless steel, 1/32" with fitting sleeve for 1/16"connections 53 AZURA® Capillary start-up kit, stainless steel 53 Accessories - Tubings Tubing start-up kits for FPLC 54 PEEK tubings , 1/16" 54 PEEK tubings , 1/8" 54 Tefzel tubings, 1/16" 54 Tefzel tubings, 1/8" 54 PTFE tubings, various OD 54

Accessories - Inline filters / osmometry Inline filters, stainless steel, for HPLC 55 Inline filters, biocompatible, for FPLC 55 Shut-off valves 55 Adapters 55 Osmometry accessories 55

Accessories - Eluent and column heating heating / purification High flow eluent and column heating devices 56 Purification 56

Accessories - Vials / caps kits Vials and caps kits for analytical HPLC 57 Vials and caps kits including microinserts for analytical HPLC 57 Vials and caps kits for preparative HPLC 57 Pliers for analytical and preparative vials 57 Sample tubes for osmometry 57

Accessories - Tools Wrenches and tightening tools 58 Capillary and tube cutter 58 Capillary grater and bender 58 Tool sets 58

Accessories - Racks / column holder LC racks 59 LC column holder 59 Installation accessories 59

Application & Academy 60 Supported devices

Pumps 61 Detectors 62 Assistant 65 Autosamplers 65 Analog/digital converters 66 Thermostats/column ovens 67 Electrical valve drives 67 Other supported devices 67 Fraction collectors 68 Mobile Control 69 Other software 70

Conversion tables 71 Notes 72 Order request 73

Page 7: AZURA® instruments & components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�1

AZURA® Pump P 6.1L The AZURA® Pump P 6.1L uses technology to overcome the challenges of pumping LC solvents at high pressure and high flow rates. This pump is designed to fulfill the needs for high pressure and low pressure mixing tasks. The pump can deliver flow in the range of 0.001 – 50 ml/min at pressures up to 1000 bar (depending on model). The AZURA® binary pump contains two identical high pressure pumps, a 2 × 2-channel inlet solvent selection valve and the new developed AZURA® mixer, a low-volume mixing device. The AZURA® quaternary pump contains one high pressure pump and an integrated LPG mixing block with a 4 channel inlet solvent selection valve and the new developed AZURA® mixer, a low-volume mixing device. The integrated degasser and AZURA® inline filter are completing the analytical AZURA® HPLC pump and turn this pump into a working horse in the lab. For biocompatible applications or ion chromatography this pump is also available with a complete metal free design. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 61.

Solvent deliveryPulsation compensation active pulsation compensationSolvent selection valve 2 x 2 channels (HPG only)Flow rate accuracy < 1%, measured at 5 - 50% of flow range using ethanol/water 10:90Flow rate precision < 0.1% RSDGradient formation High pressure binary mixingGradient range 0 - 100%HPG: minimum increment 0.1%HPG: gradient accuracy ± 1% (5 - 95%, measured at 5 - 50% of flow range, water/ caffeine tracer)HPG: gradient precision 1% RSD, based on retention time at constant room temperaturePiston seal washing standardSystem protection soft start, Pmin and Pmax are programmableWetted materials stainless steel, graphite fiber reinforced PTFE, FKM, PEEK, sapphire, aluminium oxide (Al2O3)Degasser module (optional)Degasser channels 4 channels, Teflon® AF (LPG module), 2 channels Teflon® AF (HPG modules)Degasser maximum flow rate 10 ml/minDegassing method gas permeation through Teflon® AF amorphous fluoropolymer membraneDegassing efficiency < 0.5 ppm dissolved O2 at 1 ml/minDegassing chamber volume 480 µl volume per channelSolvent applicability universal, with the exception of hydrochloric acid and halogenated hydrocarbons - in particular hexafluoroisopropanol (HFIP)Wetted materials PEEK, Tefzel®, Teflon® AFVacuum chamber polypropylene and stainless steelVacuum pump low hysteresis behaviorCommunicationControl LAN; analog and event controlledDisplay Mobile Control (optional)Analog inputs 0 - 10 VAnalog control input flow rateTechnical parametersAmbient conditions temperature range: 10 - 40 °C; 50 - 104 °F

air humidity: below 90% (non condensing)Leak sensor yesGeneralPower supply voltage range: 100 - 240 V, 50 - 60 HzDimensions 361 x 208.2 x 523 mm (W x H x D)

(U)HPLC pump

General specifications

Page 8: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�2

APH34GA AZURA® Pump P 6.1L (LPG), with 5 ml pump head (stainless steel), degasser and mixer (100 µl)APH35GA AZURA® Pump P 6.1L (HPG), with 5 ml pump head (stainless steel), degasser and mixer (100 µl)

Ordering details:

AZURA® Pump P 6.1L with 5 ml pump head

Pump head 10 ml/min

Pump head materials stainless steel

Maximum delivery pressure 70 Mpa (700 bar, 10150 psi) up to 5 ml/min, 40 MPa (400 bar, 5800 psi)

Flow rate range 0.001 - 10 ml/min

Flow rate increment 0.001 ml/min

AZURA® Pump P 6.1L with 10 ml pump head

Pump head 5 ml/minPump head materials stainless steelMaximum delivery pressure 100 Mpa (1000 bar, 14500 psi) up to 2 ml/min, 70 MPa (700 bar, 10150 psi)Flow rate range 0.001 - 5 ml/minFlow rate increment 0.001 ml/min

Specifications

Specifications

APH30EA AZURA® Pump P 6.1L isocratic, without degasser, with 10 ml pump head (stainless steel)APH30ED AZURA® Pump P 6.1L isocratic, without degasser, with 10 ml NP pump head (stainless steel)APH34EA AZURA® Pump P 6.1L (LPG), with 10 ml pump head (stainless steel), degasser and mixer (100 µl)APH35EA AZURA® Pump P 6.1L (HPG), with 10 ml pump head (stainless steel), degasser and mixer (100 µl)APH35ED AZURA® Pump P 6.1L (HPG), with 10 ml NP pump head (stainless steel), degasser and mixer (100 µl)APH38EA AZURA® Pump P 6.1L (HPG), without degasser, with 10 ml pump headAPH38ED AZURA® Pump P 6.1L (HPG), without degasser, with 10 ml NP pump head and mixer (100 µl)APH39EA AZURA® Pump P 6.1L (LPG), without degasser, with 10 ml pump head (stainless steel) and mixer (100 µl)

Ordering details:

(U)HPLC pump

Page 9: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�3

AZURA® Pump P 6.1L semi-prep

APH30FA AZURA® Pump P 6.1L isocratic, without degasser, with 50 ml pump head (stainless steel)

APH38FA AZURA® Pump P 6.1L (HPG), without degasser, with 50 ml pump head (stainless steel) and mixer (200 µl)

Ordering details:

APH60EB AZURA® Pump P 6.1L, isocratic, without degasser, with 10 ml pump head (ceramic)APH60FB AZURA® Pump P 6.1L, isocratic, without degasser, with 50 ml pump head (ceramic)APH64EB AZURA® Pump P 6.1L (LPG), with 10 ml pump head (ceramic), degasser and mixer (250 µl)APH65EB AZURA® Pump P 6.1L (HPG), with 10 ml pump head (ceramic), degasser and mixer (250 µl)APH68EB AZURA® Pump P 6.1L (HPG), without degasser, with 10 ml pump head (ceramic) and mixer (250 µl)APH68FB AZURA® Pump P 6.1L (HPG), without degasser, with 50 ml pump head (ceramic) and mixer (250 µl)APH69EB AZURA® Pump P 6.1L (LPG), without degasser, with 10 ml pump head (ceramic) and mixer (250 µl)

AZURA® Pump P 6.1L metal-free

Pump head 10 ml/min or 50 ml/min

Pump head materials ceramic

Maximum delivery pressure 10 ml pump head: 40 MPa (400 bar, 5800 psi)

50 ml pump head: 20 MPa (200 bar, 2900 psi)

Flow rate range 0.001 - 10 ml/min or 0.001 - 50 ml/min

Flow rate increment 0.001 ml/min

Specifications

Pump head 50 ml/min

Pump head materials stainless steel

Maximum delivery pressure 30 Mpa (300 bar, 4351 psi) up to 10 ml/min, 20 MPa (200 bar, 2900 psi)

Flow rate range 0.001 - 50 ml/min

Flow rate increment 0.001 ml/min

Specifications

(U)HPLC pump

Ordering details:

Page 10: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�4

SpecificationsSolvent deliveryPump type preparative HPLC pumpDelivery system double piston pump with Al2O3 pistonsPump head 100 ml / 250 ml / 500 ml / 1000 mlPump head materials stainless steel /titaniumMaximum delivery pressure for 100 ml pump head: 40 MPa (400 bar, 5800 psi); for 250 ml pump head: 22,5 MPa (225

bar, 3260 psi) up to 100 ml/min, 20 MPa (200 bar, 2900 psi) up to 250 ml/min; for 500 ml pump head: 10 MPa (100 bar, 1450 psi); for 1000 ml pump head: 7.5 MPa (75 bar, 1080 psi) up to 350 ml/min, 5 MPa (50 bar, 720 psi) up to 1000 ml/min

Flow rate range 0.01 - 100 ml/min / 0.01 - 250 ml/min / 0.01 - 500 ml/min / 0.1 - 1000 ml/minFlow rate increment 0.01 ml/min (0.1 ml/min for 250/500/1000 ml pump head)Flow rate accuracy ± 2%, measured at 5 - 50% of flow range using ethanol/water 10:90Flow rate precision < 0.1% RSDGradient support isocratic, upgradeable to a binary HPG system with additional pump P 2.1L or to a binary

or ternary LPG systemHPG: gradient accuracy ± 2% (5 - 95%,  measured at 5 - 50% of flow range, water/caffeine tracer)HPG: gradient precision 1% RSD, based on retention time at constant room temperatureLPG: gradient accuracy ± 3% (5 - 95%,  measured at 5 - 50% of the flow range, water/caffeine tracer)LPG: gradient precision 2% RSD, based on retention time at constant roomSystem protection soft start, Pmin and Pmax are programmableWetted materials stainless steel, graphite fiber reinforced PTFE, FKM, PEEK, sapphire, aluminum oxide

(Al2O3), stainless steelCommunicationControl LAN; analog and event controlledDisplay Mobile Control (optional)Analog inputs 0 - 10 VAnalog control input flow rateLevel/event outputs 8 event outputs (TTL, OC, relays)Programming 19 programs + 9 links (to programs) + 1 wake up programSpecial features system pump head is detected automatically using radio frequency identification (RFID)Technical parametersAmbient conditions temperature range: 10 – 40 °C; 50 – 104 °F

air humidity: below 90% humidity (non condensing)Leak sensor yesGeneralPower supply voltage range: 100 – 240 V, 50 – 60 HzDimensions 361 x 208.2 x 523 mm (W x H x D)Weight 19 kgOptional accessories ternary low pressure gradient valve block, 10 – 220 ml/min

binary low pressure gradient valve block, 10 – 800 ml/min pump head heating and cooling device

Preparative HPLC pump

AZURA® P 2.1L Preparative HPLC pump

AZURA® preparative HPLC pump P 2.1L covers a wide flow rate range and pressure capabilities. It has been designed for purification of mg and gram samples. The integrated automatic recognition of the pump head with RFID technology allows fast adaptions of the pump for various applications. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 61.

APE20KA P 2.1L Pump P 2.1L with 100 ml pump head (stainless steel) APE20LA P 2.1L Pump P 2.1L with 250 ml pump head (stainless steel) APE20MA P 2.1L Pump P 2.1L with 500 ml pump head (stainless steel) APE20NA P 2.1L Pump P 2.1L with 1000 ml pump head (stainless steel) APE20KB P 2.1L Pump P 2.1L with 100 ml pump head (titanium) APE20LC P 2.1L Pump P 2.1L with 250 ml pump head (titanium) APE20MC P 2.1L Pump P 2.1L with 500 ml pump head (titanium) APE20NB P 2.1L Pump P 2.1L with 1000 ml pump head (titanium) AZZ00AA LPG module for Pump P 2.1L binary up to 800 ml/min AZZ00AB LPG module for Pump P 2.1L ternary up to 220 ml/min AZZ10AB LPG module for Pump P 2.1L ternary, PEEK max. flowrate up to 220 ml/min

Ordering details:

Page 11: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�5

Compact HPLC pumps

AZURA® Pump P 4.1S AZURA® Pump P 4.1S was developed for eluent delivery up to 400 bar and for flow rates up to 50 ml/min in HPLC and other applications where a compact easy-to-integrate pump is required. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 61.

Key features • integrated pressure sensor

• versatile due to wide flow rate range (0.01–50 ml/min)

• powerful and precise drive, with low pulsation

• compact dimensions

• flexible control via Ethernet, RS-232 and analog signals

Specifications

Pump type ultra-compact high pressure pumpDelivery system dual piston pump with one working piston, one auxiliaryPump head 10 / 50 ml/minPump head materials ceramic/SSTMaximum delivery pressure 40MPa 10ml & 15MPa 50ml pump headMaximum flow rate 10 ml pump head:

0.01–10 ml/min (0.1–8.0 ml/min recommended, 0.1-4.0 ml/min continuous operation) 50 ml pump head: 0.01–50 ml/min (1.0–40 ml/min recommended, 0.1-25.0 ml/min continuous operation)

Flow rate increment 0.01 ml/minFlow rate accuracy ± 1%, measured at 5–50% of flow range using ethanol/water 10:90Flow rate precision ≤ 0.5 % RSD, measured at 1/ 5 ml/min using ethanol/water 10:90System protection Pmin and Pmax are programmableWetted materials graphite fiber reinforced PTFE, FKM, PEEK, sapphire, zirconium oxide (ZrO2),

titanium and pump head materialMax. viscosity 100 mPa·s (at reduced max. flow)Liquid temperature range -10–60 °CCommunicationControl LAN, RS-232, analog and event controlledAnalog inputs 0–10 VAnalog control input flow rateTechnical parametersAmbient conditions temperature range: 10–40 °C; 50–104 °F

air humidity: below 90 % humidity (non-condensing)GeneralPower supply 100–240 V power supply inclduded, 24 V DC, 60 WDimensions 113 x 135 x 225 mm (W x H x D)

APG20EA AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min pump head, stainless steelAPG20EB AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min pump head, ceramicAPG20EF AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min pump head, ceramic, with Ti-connectionsAPG20FA AZURA® Pump P 4.1S compact HPLC pump with 50 ml/min pump head, stainless steelAPG20FB AZURA® Pump P 4.1S compact HPLC pump with 50 ml/min pump head, ceramic

Ordering details:

Page 12: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�6

Compact HPLC pumps

AZURA® Pump P 2.1S AZURA® Pump P 2.1S was developed for eluent delivery up to 400 bar and for flow rates up to 50 ml/min in HPLC and other applications where a compact easy-to-integrate pump is required. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 61.

Key features • versatile due to wide flow rate range (0.01–50 ml/min)

• powerful and precise drive, with low pulsation

• compact dimensions

• flexible control via Ethernet, RS-232 and analog signals

Specifications

Pump type ultra-compact high pressure pumpDelivery system dual piston pump with one working piston, one auxiliaryPump head 10 / 50 ml/minPump head materials ceramic/SST/Hastelloy CMaximum delivery pressure 40MPa 10ml & 15MPa 50ml pump headMaximum flow rate 10 ml pump head:

0.01–10 ml/min (0.1–8.0 ml/min recommended, 0.1-4.0 ml/min continuous operation) 50 ml pump head: 0.01–50 ml/min (1.0–40 ml/min recommended, 0.1-25.0 ml/min continuous operation)

Flow rate increment 0.01 ml/minFlow rate accuracy ± 5%, measured at 5 - 50% of flow range using ethanol/water 10:90

± 2% at calibration point (one point calibration), measured at 5 - 50% of flow range using ethanol/water 10:90

Flow rate precision ≤ 0.5 % RSD, measured at 1 / 5 ml/min using ethanol/water 10:90System protection Imin and Imax are programmable, (I ~ pressure, pump without pressure sensor)Wetted materials graphite fiber reinforced PTFE, FKM (FFKM for APG90EC and APG90FC),

PEEK (PCTFE for APG90EC and APG90FC), sapphire, zirconium oxide (ZrO2) and pump head material

Max. viscosity 100 mPa·s (at reduced max. flow)Liquid temperature range -10–60 °CCommunicationControl LAN, RS-232, analog and event controlledAnalog inputs 0–10 VAnalog control input flow rateTechnical parametersAmbient conditions temperature range: 10–40 °C; 50–104 °F

air humidity: below 90 % humidity (non-condensing)GeneralPower supply 100–240 V power supply inclduded, 24 V DC, 60 WDimensions 113 x 135 x 225 mm (W x H x D)

APG90EA AZURA® Pump P 2.1S compact HPLC pump with 10 ml/min pump head, stainless steelAPG90EB AZURA® Pump P 2.1S compact HPLC pump with 10 ml/min pump head, ceramicAPG90EC AZURA® Pump P 2.1S compact HPLC pump with 10 ml/min pump head, Hastelloy CAPG90FA AZURA® Pump P 2.1S compact HPLC pump with 50 ml/min pump head, stainless steelAPG90FB AZURA® Pump P 2.1S compact HPLC pump with 50 ml/min pump head, ceramicAPG90FC AZURA® Pump P 2.1S compact HPLC pump with 50 ml/min pump head, Hastelloy C

Ordering details:

Detailed information on dosing pumps in the Product Selection Guide: http://tinyurl.com/dosingpumps

Page 13: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�7

Specifications

CommunicationInterface LANControl Mobile Control, softwareInputs Error (IN), Start (IN), both TTLOutputs Event 1 - 3 (OC, Relay), Error (OUT), +5 V, +24 VAnalog output integrator output (detector signal)GeneralPower supply 100 - 240 V, 50 - 60 Hz, maximum 100 WDimensions 361 x 158 x 523 mm (W x H x D)Weight about 14 kg (depending on integrated modules)Leak sensor yesTechnical parametersAmbient conditions temperature range: 4 - 40 °C, 39.2 - 104 °F

humidity: below 90 % non-condensingIntegrated modules Please consider technical parameters of integrated modules.

Assistant

AZURA® Assistant ASM 2.1L A flexible combination module The AZURA® Assistant ASM 2.1L is a compact combination module which can be equipped with up to three device modules. Available for selection are valves, pumps, degassers and a UV detector. Depending on the integrated modules, the assistant fulfills many different tasks like sample and buffer selection, sample injection, column switching or fraction collection. An assistant including a pump, valve and detector features a compact chromatographic system. As a part of a larger system the ASM 2.1L is extremely versatile in analytical, preparative and continuous liquid chromatography. The concept of flexible combination of device modules combines highest functionality with minimal space requirements. For detailed information on assistant configuration, service and software features, please visit the assistant site on the KNAUER website: http://www.knauer.net/en/products/assistants.html A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 65.

Configure the AZURA® Assistant ASM 2.1L: Pumps, Valves, Degasser, UV detector

ClarityChrom® OpenLAB® Mobile Controlversion 4 / version 5

Two pumps (independent) yes no no / yes

Fraction valve one one no / yes, but time-based

Injection module no no yes, but part of a method

ClarityChrom® OpenLAB® PurityChrom®

Two pumps (independent) no yes yes

Fraction valve no cascading (Multi valve fraction collector)

one

Injection module* yes, but part of a method yes, fully automatic module with trigger for data acquisition

yes, but part of a method

Single device configuration: The ASM 2.1L is not supported as device. Integrated modules are addressed as separate devices via IP port.

*An injection module is a combination of one pump and one 6 port 2 position valve.

Software functions supported by the ASM 2.1L

Assistant Configuration: The ASM 2.1L is supported as complete device. Modules are addressed via the assistant.

Maximum number of modules for each assistant and configuration notes • 1x degasser

An assistant with only degasser is not allowed. • 1x detector• 2x VICI valve drives AWB02 • 2x pumps

No HPG (high pressure gradient) is supported.

An AZURA® Pump P 4.1S cannot be placed to the right of a detector AZURA® Detector UVD 2.1S.

Page 14: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�8

Assistant

Order flow cells on page 43.

Compact Pump Pressure sensorPump head

Article numberVolume Material

AZURA® Pump P 2.1S No

10 mlstainless steel APG90EAHastelloy C APG90EC

ceramic APG90EB

50 mlstainless steel APG90FAHastelloy C APG90FC

ceramic APG90FB

AZURA® Pump P 4.1SYes

10 mlstainless steel APG20EA

ceramic APG20EB

50 mlstainless steel APG20FA

ceramic APG20FB

Yes 50 bar

10 ml ceramic APG17EB50 ml ceramic APG17FB

Pumps

Ports Position Material Connection Bore size Pressure limit Flow rate Article number*

6 Port

2 Positionstainless steel

1/16" 0,6 mm 300 bar 100 ml/min AWA10AA1/16" 0,3 mm 400 bar 50 ml/min AWA11CA1/16" 0,3 mm 1200 bar 10 ml/min AVC28AC & AWB02*1/8" 1,2 mm 300 bar 500 ml/min AWA10AD

PEEK1/16" 0,6 mm 200 bar 50 ml/min AWA10AC1/8" 1,2 mm 200 bar 500 ml/min AWA10AE

Multipositionstainless steel

1/16" 0,6 mm 300 bar 100 ml/min AWA10BA1/16" 0,3 mm 400 bar 50 ml/min AWA11DA1/16" 0,3 mm 1200 bar 10 ml/min AVR28AC & AWB02*1/8" 1,2 mm 300 bar 500 ml/min AWA10BC

PEEK1/16" 0,6 mm 200 bar 50 ml/min AWA10BB1/8" 1,2 mm 200 bar 500 ml/min AWA10BD

8 Port Multiposition stainless steel 1/16" 0,3 mm 1200 bar 10 ml/min AVR38AC & AWB02*12 Port Multiposition stainless steel 1/8" 1,2 mm 25 bar 500 ml/min AWA20BG16 Port Multiposition stainless steel 1/16" 0,6 mm 50 bar 100 ml/min AWA30BH

Valves

Type Single wavelength Wavelenth range Fiber Optics Connectors Article numberUV variable 190 - 500 nm No ADA00

Type Channels Article numberanalytical 2 AZE02

semi-preparative 2 AZE34

Degassers

* Products with two article numbers consist of valve and valve drive (AWB02) separately.

Detector

Assistant modules Please consider that listed article numbers represent standalone devices.

VWinter
Rechteck
VWinter
Linien
Page 15: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�9

Specifications

Sample injectionMaximum back pressure see device versions Vial/plate dimensions max. plate/vial height: 47 mm (incl. septa or capmat)Injection volume range 0.1 – 10.000 µl programmableSample loop see device versions Sample capacity analytical versions: microtiter plates for max. 768 samples or sample plates for max. 108 vials

preparative versions: 24 vials, 10 ml each (LSV)Dispenser syringe see device versions Headspace pressure built-in compressor, only for vials with septumSwitching time inj. valve < 100 msPiercing precision needle ± 0.6 mmSample tray cooling/heating

4 - 40 °C (4 - 20 °C for versions with sample cooling only: AAA21AA, AAA31AA and AAA41AA)

Vial detection missing vial/well plate detection by sensorNeedle wash programmable: wash between injections and wash between vialsWetted materials Tefzel®, Vespel®, glass, Teflon® (PTFE),

standard versions: stainless steel, PEEK; bio versions: PEEK.

Buffer tubing see device versions Sample loop see device versions Analytical performanceInjection modes full loop, partial loopfill and µl pickup mode; PASA™ (pressure-assisted sample aspiration)Injection precision RSD (Relative Standard Deviation):

full loop injection: <0.3%,partial loop injection at an injection volume >10 µl: <0.5%µl pickup injection at an injection volume >10 µl: <1.0%

Injection volumes full loop: max. 10000 µl , partial loop: max. 5000 µl (50% loop volume)µl pickup: max. 4625 µl (50% loop volume - 1,5x needle volume)0,1 µl increment for all injection modes

Sample carryover < 0.05% with standard wash; typically < 0.01% with extra washInjections per vial max. 9 injectionsInjection cycle time minimum 7 s from the same vial, 14 s from different vials;

< 60 s for ≤ 100 µl sample injection in all injection modes, incl. 300 µl needle washAnalysis time max. 9 h, 59 min, 59 sCommunicationInputs 2 programmable TTL inputs (next injection, freeze, stop)Outputs 1 programmable relay output (inject marker, auxiliary, alarm)Control Ethernet (LAN)Display Mobile Control (optional)GeneralPower supply 90 – 230 V AC ± 10%; 50 – 60 Hz; 200 VADimensions (W x H x D) 300 x 360 x 510 mm

cool/heat versions: 300 x 360 x 575 mmWeight 30 kg

cool/heat versions: 32 kgTechnical parametersAmbient conditions temperature range: 4 – 40 °C; 39.2 – 104 °F

air humidity: below 90% humidity (non-condensing)

AZURA® Autosampler AS 6.1L The AZURA® Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. This autosampler is also suitable for UHPLC with pressure stability up to 700 or 1240 bar (depending on version) and minimized dead volume for high resolution. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 65.

Autosampler

Page 16: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�10

AAA00AA AZURA® Autosampler AS 6.1L analytical HPLC autosampler, 700 barAAA01AA AZURA® Autosampler AS 6.1L analytical HPLC autosampler, 700 bar, with sample cooling/heatingAAA10AA AZURA® Autosampler AS 6.1L analytical HPLC autosampler, 1240 barAAA11AA AZURA® Autosampler AS 6.1L analytical HPLC autosampler, 1240 bar, with sample cooling/heatingAAA20AA AZURA® Autosampler AS 6.1L analytical HPLC autosampler with biocompatible flow pathAAA21AA AZURA® Autosampler AS 6.1L analytical HPLC autosampler with biocompatible flow path and sample coolingAAA22AA AZURA® Autosampler AS 6.1L analytical HPLC autosampler with biocompatible flow path and sample cooling/heatingAAA31AA AZURA® Autosampler AS 6.1L preparative HPLC autosampler with biocompatible flow path and cooling optionAAA40AA AZURA® Autosampler AS 6.1L preparative HPLC autosamplerAAA41AA AZURA® Autosampler AS 6.1L preparative HPLC autosampler with sample cooling

Ordering details:

Autosamplers

Version Basic Basic Cool/HeatOrder number AAA00AA AAA01AAMaximum back pressure 700 bar 700 barSample needle 15 µl 15 µlDispenser syringe 250 µl 250 µlBuffer tubing 500 µl 500 µlSample loop 100 µl, 0.4 mm ID 100 µl, 0.4 mm ID

Device versions

Basic

Version Standard Cool/HeatOrder number AAA10AA AAA11AAMaximum back pressure 1240 bar 1240 barSample needle 15 µl 15 µlDispenser syringe 250 µl 250 µlBuffer tubing 500 µl 500 µlSample loop 10 µl, 0.18 mm ID 10 µl, 0.18 mm ID

Standard

Version Bio Bio Cool Bio Cool/HeatOrder number AAA20AA AAA21AA AAA22AAMaximum back pressure 345 bar 345 bar 345 barSample needle 60 µl 60 µl 60 µlDispenser syringe 250 µl 250 µl 250 µlBuffer tubing 500 µl 500 µl 500 µlSample loop 100 µl, 0.4 mm ID 100 µl, 0.4 mm ID 100 µl, 0.4 mm ID

Bio*

Version Bio Cool Prep Prep Cool PrepOrder number AAA31AA AAA41AA AAA40AAMaximum back pressure 200 bar 200 bar 200 barSample needle 60 µl 60 µl 60 µlDispenser syringe 2500µl 2500µl 2500µlBuffer tubing 2000 µl 2000 µl 2000 µlSample loop 10 ml 10 ml 10 ml

Prep

*biocompatible

Page 17: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�11

Column thermostat

AZURA® Column Thermostat CT 2.1 The AZURA® Column Thermostat CT 2.1 is a price attractive basic column thermostat. It allows temperature control in the range of 5 °C and 85 °C and thus is appropriate for most HPLC applications. For advanced purification and analysis purposes, the thermostat can optionally be equipped with an eluent pre-heating cartridge. This ensures even more constant separation conditions leading to higher selectivity and an improved peak shape.

The instrument operates with a microprocessor controlled Peltier element for precise temperature settings. In combination with its high temperature stability, this allows programming of linear as well as non-linear temperature gradients. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 67.

A05852 AZURA® Column Thermostat CT 2.1 with accessories A05852-3 Cartridge for AZURA® Column Thermostat CT 2.1 Eluent Pre-heating ID 0.1 mm A05852-2 Cartridge for AZURA® Column Thermostat CT 2.1 Eluent Pre-heating ID 0.18 mm A05852-1 Optional keyboard unit for stand-alone functionality of AZURA® Column Thermostat CT 2.1

Ordering details:

SpecificationsThermostattingHeating and cooling system microprocessor controlled Peltier element for heating and cooling, fan supported 2-way

air circulationTemperature range 5 – 85 °CHeating/cooling rate 2 °C/minTemperature accuracy ± 0.2 °CTemperature stability ± 0.1 °CTemperature adjustment 1 °C stepsColumn compartmentColumn dimensions

* total outer dimensions of the column including screw caps

Dimensions, interior 90 x 390 x 47 mm (W x H x D)Safety self-check and auto-calibration at power-on; selectable turn-off temperatureLeak sensor adjustable sensitivity; acoustic signal; turn-off switchOptional accessories Cartridge for eluent pre-heating for capillary with an ID of 0.1 or 0.18 mmCommunicationInterfaces LAN InterfaceControl optional for stand-alone functionality: Keyboard unit or softwareGeneralPower supply 90 – 230 V, 50 – 60 Hz, 100 WDimensions 150 x 470 x 310 mm (W x H x D)Weight 8.4 kg

max. number max. length* max. outer diameter* matching Vertex Pluscolumn

8 160 mm 12 mm 125 mm x 4.6 mm ID4 325 mm 12 mm 300 mm x 4.6 mm ID

1 325 mm 35 mm 300 mm x 16 mm ID

Page 18: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�12

Diode array detectors

Specifications

DetectionDetector type diode array detector Number of diodes 1024Detection channels 8 (Digital), 4 (Analog)Light source high brightness deuterium (D2) lamp and halogen lamp with integrated GLP chipWavelength range 190 - 1000 nmSpectral bandwidth < 3.5 nm at Hα line (FWHM)Wavelength accuracy ± 1 nmWavelength verification internal holmium filter and deuterium linesNoise ± 3.5 µAU at 254 nmDrift 300 µAU/h at 254 nmLinearity > 2.5 AU at 274 nmTime constants 0.0 / 0.01 / 0.02 / 0.005 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 sFlow cell not included (see Accessories / Spare parts)CommunicationMaximum data rate 100 Hz (LAN), 12.5 Hz (analog)Inputs Error (IN), Start (IN), AutozeroOutputs Events 1 - 2, Error (OUT), + 5 V, Valve + 24 V, Valve (OUT)Analog outputs 4 x 0 - 5 V, 16 bitControl LAN; analog and event controlledProgramming wake upTechnical parametersGLP detailed report including lamp recognition, operating hours,

lamp operating hours, number of lamp ignitionsDisplay Mobile Control (optional)Ambient conditions temperature range: 4 - 40 °C, 39.2 - 104 °F

humidity: below 90 % non-condensingGeneralPower supply 100 – 240 V, 50 – 60 Hz, 75 WDimensions 361 x 158 x 523 mm (W x H x D)Weight 13.8 kgLeak sensor yes

AZURA® Detector DAD 6.1L The AZURA® DAD 6.1L is a high-end diode array detector (DAD) which combines outstanding performance with easy handling. A wide range of easily exchangeable flow cells make this device the right choice for fast, standard analytical, semi-preparative and preparative separations with bio-compatible or stainless steel wetted parts. State-of-the-art total reflection flow cells (LightGuide technology) are available for this detector providing maximum light throughput (due to total internal reflection) with minimal peak dispersion (due to small cell volume) to guarantee an optimized signal to noise (S/N) ratio. An optional fiber optics adapter offers the possibility to separate the flow cell spatially from the device and thus provides enhanced security for hazardous, explosive or toxic work processes, as well as protecting the device from leakages at high flow rates. The newly developed optical unit with KNAUER Polka-Dot technology and intelligent temperature management ensure maximum sensitivity combined with minimal baseline drift over the whole spectrum. Furthermore, easy frontal access and improved safety features enable effortless lamp replacement. This eases maintenance and guarantees short downtimes. The DAD 6.1L comes installed with a high brightness deuterium and tungsten halogen lamps, which cover a wavelength range from 190 to 1000 nm. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

ADC11 AZURA® Detector DAD 6.1L Diode array detector DAD 6.1L without flow cell 190 - 1000 nmAMC19XA 10mm, 2µl, 1/16", 50bar LightGuide Flow cell cartridge for AZURA® Detector DAD/MWDAMD59XA 50mm, 6µl, 1/16", 50bar High Sensitivity LightGuide Flow cell cartridge for AZURA® Detector DAD/MWDAMC38 10mm, 10µl, 1/16", 300bar PressureProof Flow cell cartridge for AZURA® Detector DAD/MWDAMB18 3mm, 2µl, 1/16", 300bar PressureProof Flow cell cartridge for AZURA® Detector DAD/MWDAZL01 Deuterium lamp type HBST for AZURA® Detector DAD 6.1L AZL02 Halogen replacement lamp for AZURA® Detector DAD 6.1L AMKX8KIT Fiber optics adapter kit for AZURA® Detector DAD/MWD AMLX8 Test cell for AZURA® Detector DAD/MWD

Ordering details:

Page 19: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�13

AZURA® Detector DAD 2.1L & MWD 2.1L The AZURA® Detector DAD 2.1L is a highly competitive diode array detector which combines high performance with easy handling at an affordable price. A wide range of easily exchangeable cartridge flow cells make this device the right choice for fast, standard analytical, semi-preparative and preparative separations with bio-inert or stainless steel wetted parts. State-of-the-art total reflection flow cells (LightGuide technology) are available for this device providing maximum light throughput (due to total internal reflection) with minimal peak dispersion (due to the small cell volume) to guarantee an optimized S/N ratio. An optional fiber optics adapter offers the possibility to separate the flow cell spatially from the device and thus provides enhanced security for hazardous, explosive or toxic work processes, as well as protecting the device from leakages at high flow rates. The newly developed optical unit and intelligent temperature management ensure for maximum sensitivity combined with minimal baseline drift. Furthermore, easy frontal access and improved safety features enable effortless lamp replacement. This eases maintenance and guarantees short downtimes. The device comes installed with a deuterium lamp which covers a wavelength range from 190 to 700 nm. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Diode array detectors

Specifications

DetectionDetector type DAD 2.1L, diode array detector / MWD 2.1L, multi-wavelength detectorNumber of diodes 256Detection channels 8 (Digital), 4 (Analog)Light source deuterium (D2) lamp with integrated GLP chipWavelength range 190 - 700 nmSpectral bandwidth < 10 nm at Hα line (FWHM)

note: digital bandwidth 1 - 32 nmWavelength accuracy ± 1 nmWavelength verification internal holmium filter and deuterium linesNoise ± 5 µAU at 254 nmDrift 300 µAU/h at 254 nmLinearity > 1.6 AU at 274 nmTime constants 0.0 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 sFlow cell not included (see Accessories / Spare parts)CommunicationMaximum data rate 100 Hz (LAN) 12.5 Hz (Analog)Inputs Error (IN), Start (IN), AutozeroOutputs Events 1 - 2, Error (OUT), + 5 V, Valve + 24 V, Valve (OUT)Analog outputs 4 x 0 - 5 V, 16 bitControl LAN; analog and event controlledProgramming wake upTechnical parametersGLP detailed report including lamp recognition, operating hours,

lamp operating hours, number of lamp ignitionsDisplay Mobile Control (optional)Ambient conditions temperature range: 4 - 40 °C, 39.2 - 104 °F

humidity: below 90 % noncondensingGeneralPower supply 100 – 240 V, 50 – 60 Hz, 75 WDimensions 361 x 158 x 523 mm (W x H x D)Weight 12.8 kgLeak sensor yes

ADC01 AZURA® Detector DAD 2.1L Diode array detector DAD 2.1L without flow cell 190 - 700 nmADB01 AZURA® Detector MWD 2.1L Multiwavelength detector MWD 2.1L, without flow cell 190 - 700 nmAMB18 3mm, 2µl, 1/16", 300bar PressureProof Flow cell cartridge for AZURA® Detector DAD/MWDAMC19XA 10mm, 2µl, 1/16", 50bar LightGuide Flow cell cartridge for AZURA® Detector DAD/MWDAMD59XA 50mm, 6µl, 1/16", 50bar High Sensitivity LightGuide Flow cell cartridge for AZURA® Detector DAD/MWDAMC38 10mm, 10µl, 1/16", 300bar PressureProof Flow cell cartridge for AZURA® Detector DAD/MWDA5193 Deuterium lamp, replacement, for S2550, S2520, 10D 40D, 50D, UVD 2.1S, UVD 2.1L DAD 2.1L, MWD 2.1LAMKX8KIT Fiber optics adapter kit for AZURA® Detector DAD/MWD AMLX8 Test cell for AZURA® Detector DAD/MWD

Ordering details:

Page 20: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�14

UV/VIS detectors

AZURA® Detector UVD 2.1L Variable single wavelength

The AZURA® Detector UVD 2.1L is a competitively priced HPLC spectrophotometer for routine HPLC applications including fast LC methods. Besides offering excellent technical specifications, this robust detector features a highly flexible and compact design. The UVD 2.1L comes with an installed deuterium lamp which covers a wavelength range from 190 to 750 nm. Due to a smart design the flow cell is easily accessible and can be changed very quickly. You can choose between a wide range of flow cells for analytical or preparative LC applications with flow rates from 10 μl/min up to 10 l/min. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Specifications

DetectionDetector type variable single wavelength UV/VIS detectorDetection channels 1Light source deuterium (D2) lamp with integrated GLP chipWavelength range 190 - 750 nmSpectral bandwidth 11 nm at Hα line (FWHM)Wavelength accuracy ± 2.5 nmWavelength precision 0.3 nm (ASTM E1657-93)Noise ± 15 µAU at 254 nm (ASTM E1657-98)Drift 300 µAU/h at 254 nm (ASTM E1657-98)Linearity > 2.0 AU at 270 nm (ASTM E1657-98)Time constants 0.0 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 sFlow cell not included (see Accessories / Spare parts)CommunicationMaximum data rate 50 Hz (LAN)

20 Hz (analog)Inputs Error (IN), Start (IN), Autozero, 1 - 10 V Analog INOutputs Events 1 - 3, + 5 V, 24 V ValveAnalog outputs 1 x 0 - 5 V scalable, 16 bit, offset adjustableControl digital: LAN; RS-232; analog and event controlled

analog: wavelength controlmanual: Mobile Control (optional)

Programming timed: wavelength, events, fraction valve, links, wake up (program, link); 9 programs, 50 program lines

Technical parametersGLP detailed report including lamp recognition, operating hours,

lamp operating hours, number of lamp ignitionsDisplay Mobile Control (optional)Ambient conditions temperature range: 4 - 40 °C, 39.2 - 104 °F

humidity: below 90 % noncondensingGeneralPower supply 100 - 240 V, 50 - 60 Hz, 75 WDimensions 361 x 158 x 523 mm (W x H x D)Weight 5.9 kgLeak sensor yes

ADA01XA AZURA® Detector UVD 2.1L with deuterium lamp without flow cellADA04XA AZURA® Detector UVD 2.1L Fiber Optics Version with deuterium lamp without flow cellA4061XB Flow cell UV, 10 mm 10 µl, 1/16", stainless steel, with heat exchanger one sided inlet and outletA4042 Flow cell UV, 3 mm, 2 µl, 1/16", stainless steel A5193 Deuterium lamp, replacement, for S2550, S2520, 10D 40D, 50D, UVD 2.1S, UVD 2.1L DAD 2.1L, MWD 2.1LA4126 Test cell Holmium Oxid Filter A4146 Test cell, WG 280 filter stray light A4123 Test cell

Ordering details:

Page 21: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�15

Specifications

DetectionDetector type variable multiple wavelength UV/VIS detectorDetection channels 4Light source deuterium (D2)Wavelength range 190 – 750 nmSpectral bandwidth 6 nm at Hα line (FWHM)Wavelength accuracy ± 2.0 nm (verification with integrated holmium oxide filter)Wavelength precision 0.4 nm (ASTM E275-93)Noise ± 7.5 μAU at 254 nm (ASTM E1657-98)Drift 150 μAU/h at 254 nm (ASTM E1657-98)Linearity > 2.2 AU at 270 nm (ASTM E1657-98)Time constants 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 sFlow cell not includedIntegration time automaticCommunicationMaximum data rate 80 Hz (LAN) 1 channel

20 Hz (Analog) 1 channel 10 Hz (RS–232) 1 channel

Inputs Error (IN), Start (IN), Autozero, 0 - 10 V Analog INOutputs Events 1 - 3, + 5 V, 24 V ValueAnalog outputs 2 x 0 - 5 V scalable, 20 bit, offset adjustableControl digital: LAN; RS-232; analog and event controlled

analog: wavelength control manual: touchpad

Programming timed: wavelengths, events, fraction valve, links, wake up (program, link); 9 programs, 50 program lines

Technical parametersGLP detailed report including lamp recognition, operating hours, lamp operating hours,

step motor operating hours, number of lamp ignitionsDisplay touchscreen TFT 2.4"Ambient conditions temperature range: 4 – 40 °C; 39.2 – 104 °F

humidity: below 90% noncondensingGeneralPower supply 100 – 240 V, 50 – 60 Hz, 75 WDimensions 242 x 169 x 399 (W x H x D)Weight 5.3 kg

UV/VIS detectors

BlueShadow UV/VIS Detector 50D Variable multiple wavelength

The BlueShadow 50D offers high sensitivity and baseline stability for HPLC applications including fast LC methods. With its high speed scanning design, up to four different wavelengths can be monitored simultaneously while acquiring spectral data from 190 to 750 nm. Its remarkable values for noise, drift, and linearity are achieved through smart optical bench technology and the use of optimized components.  The detector comes installed with a deuterium lamp which covers a wavelength range from 190 to 750 nm. Due to a smart design the flow cell is easily accessible and can be changed very quickly. A wide range of flow cells is available for practically any LC application, including micro flow cells for flow rates up to 10 μl/min and flow cells for preparative HPLC up to 10 l/min. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

C55190XA.0 UV-Detector BlueShadow 50D, flow cell excluded, accessories includedA4061XB Flow cell UV, 10 mm 10 µl, 1/16", stainless steel, with heat exchanger one sided inlet and outletA4042 Flow Cell UV, 3 mm, 2 µl, 1/16", stainless steel A5193 Deuterium lamp, replacement, for S2550, S2520, 10D 40D, 50D, UVD 2.1S, UVD 2.1L DAD 2.1L, MWD 2.1LA4126 Test cell Holmium Oxid Filter A4146 Test Cell, WG 280 filter stray light A4123 Test cell

Ordering details:

Page 22: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�16

UV/VIS detectors

AZURA® Detector UVD 2.1S Small variable single wavelength

The AZURA® UVD 2.1S is a highly competitive single variable wavelength UV detector for HPLC and purification applications such as Prep LC and FPLC. It offers excellent technical specifications for routine laboratory work. With its small footprint, it is one of the smallest detectors for HPLC on the market. The UVD 2.1S comes in the novel small AZURA® housing. The installed deuterium lamp covers a wavelength range from 190 to 500 nm. Due to a smart design the flow cell is easily accessible and can be changed very quickly. You can choose between a wide range of flow cells for analytical or preparative LC applications with flow rates from 10 μl/min up to 10 l/min. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Specifications

Detection Detector type small variable single wavelength UV detectorDetection channels 1Light source deuterium (D2) lamp with integrated GLP chipWavelength range 190 - 500 nmSpectral bandwidth 13 nm at Hα line (FWHM)Wavelength accuracy ± 3 nmWavelength precision 0.7 nm (ASTM E1657-93)Noise 20 µAU at 254 nm (ASTM E1657-98)Drift 300 µAU/h at 254 nm (ASTM E1657-98)Linearity > 2.0 AU at 270 nm (ASTM E1657-98)Time constants 0.00 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 sFlow cell not included (see Accessories / Spare parts)CommunicationMaximum data rate 50 Hz (LAN, Analog)

10 Hz (RS-232)Inputs Autozero, Start (IN), Error (either IN or OUT), 1 - 10 V Analog INOutputs Error (either OUT or IN)Analog outputs 1 x ± 2.5 V scalable, 20 bitControl digital: LAN; RS-232; analog and event controlled

analog: wavelength controlmanual: front panel or software

Technical parametersGLP lamp operating hoursDisplay LED or Mobile Control (optional)Ambient conditions temperature range: 4 - 40 °C, 39.2 - 104 °F

humidity: below 90% noncondensingGeneralPower supply external: input 100 - 240 V, output 24 V DC, 60 WDimensions 121 x 129 x 187 mm (W x H x D)Weight 1.5 kg

ADA00 AZURA® Detector UVD 2.1S with deuterium lamp without flow cellADA05 AZURA® Detector UVD 2.1S Fiber Optics Version with deuterium lamp without flow cellA4061XB Flow cell UV, 10 mm 10 µl, 1/16", stainless steel, with heat exchanger one sided inlet and outletA4042 Flow Cell UV, 3 mm, 2 µl, 1/16", stainless steel A5193 Deuterium lamp, replacement, for S2550, S2520, 10D 40D, 50D, UVD 2.1S, UVD 2.1L DAD 2.1L, MWD 2.1L

Ordering details:

Page 23: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�17

Refractive index detector

AZURA® Detector RID 2.1L Analytical refractive index detector

The AZURA® RID 2.1L is a sensitive and competitively priced differential refractometer suitable for detecting compounds with little or no UV activity such as alcohols, sugars, lipids or polymers. This instrument is designed for use in analytical HPLC (high performance liquid chromatography) as well as for GPC (gel permeation chromatography) applications. The intelligently designed optical unit with advanced temperature control ensures high sensitivity, fast baseline stabilization, and excellent reproducibility. Furthermore, the long-life LED, highly pressure resistant flow cell, improved safety features and enhanced diagnostics functions guarantee easy handling and minimal maintenance. The wide linear dynamic range and 10 ml/min maximum flow rate make the AZURA® RID 2.1L the perfect choice for most laboratory tasks. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Specifications

DetectionDetector type analytical refractive index detectorLight source long-life LEDRefractive index range 1.00 - 1.75 RIUNoise ± 2.5 nRIUDrift 200 nRIU/hLinearity > 1000 µRIUTemperature control OFF, 30 - 55 °C (1 °C increment)Maximum flow rate 10 ml/min (pure water)Time constants 0.00 / 0.01 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 sAutozero full rangeFlow cell 5 bar back pressure resistence

flow cell includedFlow cell volume 15 μlWetted materials stainless steel / fused silica / PTFE / PEEKCommunicationMaximum data rate 100 Hz (LAN)

20 Hz (Analog)Inputs Error (IN), Start (IN), Autozero, Flush (IN)Outputs Event 1, Start (OUT), Error (OUT), + 5 V, 24 V ValveAnalog outputs 1 x 0 - 2.5 V scalable, 20 bit, offset adjustableControl digital: LAN; analog and event controlled

manual: softwareTechnical parametersGLP detailed report including operating hours, light source operating hoursDisplay Mobile Control (optional)Ambient conditions temperature range: 4 - 40 °C, 39.2 - 104 °F

humidity: below 90 % noncondensingGeneralPower supply 100 - 240 V, 50 - 60 Hz, 60 WDimensions 361 x 158 x 523 mm (W x H x D)Weight 10.8 kgLeak sensor yes (internal and external leak management)

Optional accessories Mobile Control

ADD31 AZURA® Detector RID 2.1L Refractive Index Detector with flow cell

Ordering details:

Page 24: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�18

Fluorescence detector

Fluorescence Detector RF-20A/Axs The fluorescence detector RF-20Axs provides world-class sensitivity, excellent maintainability and diverse validation / support functions. It supports a wide range of applications in the wavelength range of 200 to 750 nm from conventional analysis to high-performance analysis. With a signal-to-noise ratio of 2000 for the water-Raman band, the fluorescence detector is very well suited for trace analysis. Measuring cell tempering ensures the lowest possible noise and drift values. The integrated low-pressure mercury lamp allows easy wavelength accuracy verification. The xenon lamp and flow cell are directly accessible on the device, thus allowing a quick and easy handling and maintenance of the device by the user, thereby minimizing downtime. The lamp life is 2000 hours. When replacing the xenon lamp, no adjustment is required. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Specifications

DetectionDetector type spectrofluorometric detectorDetection channels 2Number of signals 2Light source xenon lamp, low-pressure; mercury lamp for wavelength accuracy check (RF-20 Axs only)Wavelength range 200 to 750 nm RF-20 Axs / 200 to 650 nm RF-20 ASpectral bandwidth 20 nmWavelength accuracy ± 2 nmWavelength precision ± 0.2 nm Indicates the precision performance when the power is turned ON in single

wavelength mode and the wavelength is changed.Sensitivity can be set at three levels: HIGH (x 1), MED (x 32), LOW (x 1024)Wetted materials SUS316L, PTFE (fluorocarbon polymers), quartzFlow cell volume 12 µmTime constants 11 levels can be selected, equivalent to "no filter", 0.05, 0.1, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0, 8.0 and

10.0 secondsAutozero auto zero function, basline shift functionHeated zoneTemperature range room temperature (ambient temperature) -10 °C up to 40 °C (at flow rates less than 2 ml/min,

column oven temperatures less than 85 °C, only for RF-20Axs)CommunicationGain can be set at three levels: x 1, x 4, x 16Technical parametersAmbient conditions operating temperature: 4 to 35 °C, relative humidity: 20 to 85 % (no condensation)GeneralPower supply AC220–240 V, 400 VA, 50/60 HzDimensions 260 x 210 x 420 mm (W x H x D)Weight 18 kg

A59200 Fluorescence detector RF-20 A 200 - 650 nm incl. accessoriesA59201 Fluorescence detector RF-20 Axs 200 - 750 nm incl. accessoriesA59210 Xenon lamp for RF-20A/Axs A59211 Flow cell for Semi micro LC cell capacity 3 µl, supports temperature control (RF-20Axs only)A59212 Inert flow cell for RF-20A/Xs, cell capacity 12 µl, contact materials: PEEK, PTFE A59213 Photomultiplier f. RF-20A/Axs, wavelength 200 nm to 900 nm A59300 CBM-20A Interface CE/IVD PC Interface (request software control option via KNAUER)A1783-3 Shimadzu LC Driver for Chromeleon 7.2 Shimadzu CBM-20A required

Ordering details:

Page 25: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�19

Light scattering detector

Light scattering detector Sedex LC/85LT/90LT Universal ELSD detection for HPLC Evaporative Light Scattering Detection (ELSD) is a universal modern technology with which every analyte that is less volatile than the mobile phase can be detected. Using the unique Low Temperature technology, this detector allows the achievement of very high sensitivity. The technology is gradient compatible and is independent of the absorption characteristics of the eluents. Compounds can be universally measured with this detector (carbohydrates, proteins, peptides, polymers, lipids, steroids, etc.), regardless of their fluorescence, absorption or refractive-index characteristics. Comprehensive SOP protocols for GLP conformity and validation procedures are available. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Specifications

DetectionDetector type high sensitivity photomultiplierLight source selected high effciency blue LED (470 nm), elapsed-time counterSensitivity < 5 ng caffein (LOD) for LC / < 1 ng caffein (LOD) for 85LT / < 0.5 ng stearic acid (LOD) for 90 LTMaximum data rate analog: 40 Hz, analog: 100 Hz 85LT, digital: 30 HzNebulizerGas nitrogen preferredGas flow rate < 3 l/minGas inlet pressure 3.5 bar (51 psi)HPLC flow rate (85 LT) HPLC nebulizer: 200 µl/min–2 ml/min

UHPLC nebulizer: 200 µl/min–1.4 ml/min low flow nebulizer: 35 µl/min–900 µl/min micro nebulizer: 4-40 µl/min

Maintenance easily accessible from the front for cleaningHeated zoneTemperature range ambient to 100 °CCommunicationGain factor 1 to 2048 in 12 steps (2 1 to 2 11)Filter moving average (0–10 seconds)Analog outputs 0–1 VAnalog control input contact closure for ready, auto-zeroControl RS-232Power-down methods shut-off: gas, LED, heating and/or PMT cleaning modeTechnical parametersDisplay liquid crystalGeneralPower supply 230 V/50 Hz, 1.7 A; 115 V/60 Hz, 1.8 ADimensions 250 mm x 480 mm x 550 mm (W x H x D)Weight 18.5 kg

A0754-1 Sensitive Light scattering detector ELSD 85LT for univ. detection 0.2 - 2.5 ml/min, 100 Hz including accessoriesA0754-3 High Sensitive Light scattering detector ELSD 90LT for univ. detection 0.2 - 2.5 ml/min, 100 Hz including accessoriesA0754-5 Preparative Light scattering detector ELSD SEDEX LC for univ. detection 200 µl/min - 2 ml/min

A2618-01 OpenLAB® CDS EZChrom Edition drivers Sedex 80/85/90LT/LC not for fraction collectionA1783-4 Sedex Driver for Chromeleon 7.2; For Sedex 85LT / 90LT / FP / LC / 100LT; Instrument Controler Class 3 necessaryA0754INST Installation ELSD including IQ, OQ and PQ for Germany, Switzerland and Austria

Ordering details:

Page 26: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�20

Electrochemical detector

Electrochemical Detector DECADE Elite SCC Single cell control/dual cell control

This detector enables you to perform all applications using electrochemical detection. The DECADE II includes a highly stable Faraday-shielded oven compartment accommodating column and flow cell. This flow cell has surprised researchers for its unsurpassed S/N ratio and provides best possible combination for extremely sensitive EC analyses. The DECADE II covers the DC, pulse and scan mode. The DC mode covers about 90% of all applications. The pulse mode is important for PAD (Pulsed Amperometric Detection) of for example carbohydrates. The scan mode is used to obtain a voltammogram in method optimization. Important parameters in the DC and pulse mode can be changed on a time base by user-defined commands, which enables maximum control to fully automate the detection. In addition, crucial parameters can be controlled by either relays or TTL. For highest sensitivity, the SenCell is recommended with carbon electrode with a 5 year warranty. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Key features

• highest sensitivity – down to the low fentomol range (on column)

• excellent precision due to thermostatically controlled Faraday’s cage for measuring cell and column

• flexible and efficient due to control of up to 4 cells

• wide selection of working and reference electrodes

• optimized signal to noise ratio via ADF (advanced digital filter)

• can be updated using flash-technology

• well-arranged display, screw connection for sample feed at the front

Specifications

DetectionDetector type electrochemical detector (DC, PAD and scan operating modes)Outputs between ± 1 V and ± 10 V (20 bit D/A converter)Autozero triggered via keypad, TTL or RS-232Control RS-232, data transmission with 1, 2, 5 or 10 HzDimensions 220 x 440 x 440 mm (W x H x D)Weight 14 kg

A07545 Electrochemical detector DECADE Elite SCC without flow cell AZB00XA AZURA® Interface Box IFU 2.1 LAN, A/D converter, 4 channels A07546 Flow cell SenCell 2 mm GC Salt-BridgeA07546-1 Flow cell FlexCell Au HyREF Flow CellA07546-2 SenCell GC HyREF Flow Cell

Ordering details:

Page 27: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�21

Conductivity detector

Conductivity detector CDD-10 Avp The CDD-10AVP is a highly sensitive conductivity detector applicable to ion chromatograph or organic acid analysis. Low noise, low drift and wide dynamic range assure proven performance of the CDD-10AVP detector. A special features is the VP key for validation. Flow cell 0.25 µl included. Further flow cells on request. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

A1252-1 Conductivity detector CDD-10 Avp with flow cell 0.25 µlAZB00 AZURA® Interface Box IFU 2.1 USB

Ordering details:

Specifications

DetectionNoise Level less than 4 nScm-1 (BG: F285 µScm-1)Drift (Time) less than 25 nScm-1 (BG: F285 µScm-1)Drift (Temperature) less than 25 nScm-1 (BG: F285 µScm-1)Ambient Temperature 4 - 35 deg. CResponse time constant: 0.05, 0.1, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0, 8.0, 10.0 sec, 10 stepsZero Adjustment auto zero, baseline shiftPorality positive and negativeMeasurement Range 0.01 - 51,200 µScm-1 FSMeasurement SensitivityGain 0.01, 0.1, 1, 10, 100 µScm-1 FS/mV, 5 stepsRange 1 - 512, SHORTDisplay LCD with Back-litOutputRecorder 10 mV recorder terminalIntegrator 100, 10, 1, 0.1, 0.01 mV/µScm-1Cell 0.25 µL volme, 2.9 MPa max. pressure, SUS316, PEEK, TeflonTemperature Control 25 - 55 deg. C (1 deg. C step), OFFPower Requirements AC100 - AC240 V, 250 VADimensions W 260 mm x D 420 mm x H 140 mm

Page 28: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�22

Conductivity/pH monitor

AZURA® Conductivity Monitor CM 2.1S Conductivity monitor with optional pH measurement

The AZURA® CM 2.1S is a reliable conductivity monitor which is utilized in FPLC to follow salt gradients. Optionally pH values can be measured. Wetted parts are completely biocompatible. The contactless measurements of conductivity reduces the risk of carryover to a minimum. Two flow cells cover a flow rate up to either 10 ml/min or 100 ml/min and are optimized for low dead volume. Please order conductivity flow cells and the pH measuring kit in addition to the CM 2.1S. A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 62.

Key features • contactless conductivity measurement • fast response • high accuracy and reproducibility, low noise • accurate and reliable monitoring through self-test and self-calibration • short capillaries for minimizing band broadening and time delay between detectors • measurement kit is optional and has to be separately ordered • optional upgrade for pH measurement is possible

Specifications

DetectionFlow cell 10 ml or 100 mlDetector type conductivityMeasurement range 1 µS/cm – 999 mS/cmDrift temperature sensor ± 0.3 °C per 10 hpH measurement 2 - 12CommunicationMaximum data rate 5 HzSupported electrodes conductivity: automatic recognition

pH: all pH electrodes with BNC connector (compatible) and available flow cell

Autozero automaticMeasurement accuracy temperature sensor accuracy: ± 1.0 °C;

conductivity accuracy: < 2% full scale or ± 5 µS/cm whichever is greater in the range 1 µS/cm – 300 mS/cm

Analog outputs 2 channels DAC 18 bit conductivity value pH Value (only for the stand-alone device)

Digital outputs LAN; RS-232Technical parametersGLP electronic Serial No.Display LCD, 2 x 8 charactersAmbient conditions operating temperature: 15 to 35 °C, relative humidity: 45 to 85%GeneralPower supply 100 – 240 V, 50 – 60 Hz, max. 20WDimensions 121 x 129 x 187 mm (W x H x D)

ADG30 AZURA® Conductivity Monitor CM 2.1S without flowcell A4156 AZURA® Conductivity Monitor CM 2.1S - flowcell for flow rates up to 10 ml/min 160 bar, ID 0,25 mm A4157 AZURA® Conductivity Monitor CM 2.1S - flowcell flow rates up to 100ml per min 100 bar, ID 0,75 mm A70091 pH measuring kit complete for conductivity monitor up to 80 ml/min A5813 Flow splitter for use of CM 2.1S over 100 ml/min

Ordering details:

ADG30

A70091

Page 29: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�23

Foxy® R1 and Foxy® R2 The Foxy® R1 and Foxy® R2 are automated fraction collectors for robust and reliable collection of fractions and can be used universally in research laboratories, for routine investigations, for analytical tasks, for semi-preparative separations and for bio compatible applications. The two-rack Foxy® R2 fraction collector uses radio frequency identification to automatically detect collection racks for easy setup.

A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 68.

Key features:

• Collect uniform fractions by time or pumped volume.

• Collect peaks of interest separately using any combination of slope, level, and time.

• Stores up to 8 collection methods.

• Choice of available racks

• Cooling option available (special cooling rack, cooling option and thermostat necessary)

• Coldroom-storage possible

• Easy to use symbolic touch screen interface

• Fast tube changes

• Small delay volume between diverter valve and drop former

Fraction collectors

Specifications Fraction collector Foxy® R1/R2

Number of racks Foxy® R1: 1 Foxy® R2: 2

RFID rack recognition Foxy® R1: no Foxy® R2: yes

Capillary connection 1/16“, 1/8“ or 1/4“Fractionation modes drop counting, time intervals, volume intervalsFractionation flow rate Foxy® R1: max. 125 ml/min (1/16“: up to 25 ml/min)

Foxy® R2: max 1000 ml/min (1/8“: up to 125 ml/min)Diverter valve drop former (NC): 110 µl

waste (NO): 130 µlWetted materials valve: PEEK and perfluoroelastomer (FFKM), supplied ferrules: ETFE, supplied valve tubing: PTFE,

supplied drain tubing: vinylFractionation control operator: front panel control via touch screen LCD

integrated systems: direct communication via Ethernet (TCP/IP) and RS-232 serial communicationsMaximum test tube height Foxy® R1: 160 mm, Foxy® R2: 196 mm, Foxy® R2 1/4“: 180 mmCooling option Special cooling racks, cooling option and thermostat necessaryCommunicationControl LAN, RS-232Technical parametersConformity CE, CSADisplay touch screen LCD displaysAmbient conditions 0 – 40 °C, 32 – 104 °FGeneralPower supply 100 – 240 VAC, 50 – 60 Hz, max. 1 ADimensions Foxy® R1: 31.1 x 35,5 x 33 mm (W x D x H)

Foxy® R2: 31.1 x 37,8 x 53,3 mm (W x D x H) Foxy® R2 1/4“: 31.1 x 39,4 x 53,3 mm (W x D x H)

Weight Foxy® R1: 7.1 kg, Foxy® R2: 10.3 kg, Foxy® R2 1/4“: 10.4 kg

A59100 Fraction collector Foxy® R1, for 1/16“ or 1/8“ tubingA59102 Fraction collector Foxy® R2, for 1/8“ tubingA591021 Fraction collector Foxy® R2, for 1/4“ tubing

Ordering details:

Page 30: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�24

Fraction collectors

Racks for Foxy® R1/R2

Article number max volume (ml)

vessel outer diameter (mm)

vessel length (mm)

Rack Foxy® R1 capacity

Foxy® R2 capacity

A59103 5 12 75 12 mm test tubes 144 288A59103 7 12 100 12 mm test tubes 144 288A59104 9 13 100 13 mm test tubes 144 288A59105 11.5 16 100 16 mm test tubes 100 200A59105 15 16 125 16 mm test tubes 100 200A59105 20 16 150 16 mm test tubes 100 200A59106 15 17 120 15 ml Falcon tubes 72 144A59106 27 18 150 18 mm test tubes 72 144A59106 32 18 180 18 mm test tubes n/a 144A59108 60 25 150 25 mm test tubes 36 72A59108 70 25 180 25 mm test tubes n/a 72A59107 1,5 10 40 1.5 ml mirco-centrifuge or Eppendorf tubes 60 120A59111 0.33-2.2 n/a n/a 96-well microplates 2 4 or 6A59110 50 29 123 50 ml Falcon tubes 36 72A59114 480 68 165 bottle 9 18A59109 unlimited n/a n/a funnel 36 36 or 72A59101 unlimited n/a n/a funnel n/a 26A59117 1.5 10 40 1.5 ml mirco-centrifuge or Eppendorf tubes 144 n/aA59118 15 17 120 15 ml Falcon tubes 72 n/aA59119 0.33-2.2 n/a n/a 96-well microplates 2 n/a

Specification:

*For Foxy R1 with cooling option

A59111 Rack for 2 microwell plates 96 well for fraction collector Foxy® R1/R2A59110 Rack for 36 falcons 50 ml for fraction collector Foxy® R1/R2 A59109 Prep. funnelrack for Foxy® R1R2 36 places with vinyl tubing A59101 Prep. funnelrack for Foxy® R2 26 places with vinyl tubing A59108 Rack for 36 vials 25 mm for fraction collector Foxy® R1/R2 A59107 Rack for 60 tubes 1.5 ml for fraction collector Foxy® R1/R2 A59106 Rack for 72 falcons 15 ml for fraction collector Foxy® R1/R2 A59105 Rack for 100 vials 16 mm for fraction collector Foxy® R1/R2 A59104 Rack for 144 vials 12 mm for fraction collector Foxy® R1/R2 A59103 Rack for 144 vials 12 mm for fraction collector Foxy® R1/R2 A59114 Racks for 2 x 9 bottles 480 ml for fraction collector Foxy® R2A59112 Funnel trays for fraction collector Foxy® R1/R2 (10 pieces) A59117* Cooling rack for 144 tubes 1.5 ml for fraction collector Foxy® R1 with coolingA59118* Cooling rack for 72 falcons 15 ml for fraction collector Foxy® R1 with coolingA59119* Cooling rack for microwell plates for fraction collector Foxy® R1 with coolingA59122 Cooling option with cooling hood, cooling plate and accessoriesA70050 Thermostatting unit -40° to 200°C A70055 Thermostatting unit -20° to 40°C

Ordering details:

Page 31: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�25

LABOCOL Vario-4000 The LABOCOL Vario-4000 fraction collectors are characterized by their small dimensions combined with an optimal space utilization. The open system without limitation of the fractions and vessel sizes can be tailored to individual needs. The fraction collectors of the LABOCOL Vario-4000 series offer the corresponding program for each application and are flexible to handle. The versatile application possibilities make the Vario-4000 series ideal for use in research and development as well as in production. The individual Vario-4000 models differ in the base area and the flow rate range.

A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 68.

Key features:

• Collect uniform fractions by time or pumped volume• Choice of available racks• Space for three or five different racks • Waste / fraction valve for 1/16“, 1/8“ or 1/4“ tubing• Flow rates up to 1000 ml/min

Fraction collectors

Specifications LABOCOL Vario 4000 and Vario-4000 Plus

Number of racks Vario-4000: 3 racks Vario-4000 Plus: 5 racks

Capillary connection 1/16“, 1/8“ or 1/4“Fractionation flow rate up to 1000 ml/minWetted materials PPEK and PTFECommunicationControl LAN, RS-232GeneralPower supply 100 – 240 VAC, 50 – 60 Hz, max. 2.5 ADimensions Vario-4000: 30 x 50 x 52 mm (W x D x H), Maximum footprint for racks: 24 x 41 (W xD)

Vario 4000 Plus: 46 x 50 x 52 mm (W x D x H), Maximum footprint for racks: 40 x 41 (W xD)Weight Vario-4000: 8 kg

Vario-4000 Plus: 10 kgAmbient conditions 0 – 40 °C, 32 – 104 °F

A591022 Fraction collector LABOCOL Vario-4000, for 1/16“ or 1/8“ tubingA591024 Fraction collector LABOCOL Vario-4000, for 1/4“ tubingA591023 Fraction collector LABOCOL Vario-4000 Plus, for 1/16“ or 1/8“ tubingA591026 Fraction collector LABOCOL Vario-4000 Plus, for 1/4“ tubingA59130 Standard rack for fraction collector LABOCOL Vario-4000 / Vario-4000 PlusA59131 Micro rack for fraction collector LABOCOL Vario-4000 / Vario-4000 PlusA59132 Prep rack for fraction collector LABOCOL Vario-4000 / Vario-4000 PlusA59133 Semiprep rack for fraction collector LABOCOL Vario-4000 / Vario-4000 PlusA59134 Falcon® rack for fraction collector LABOCOL Vario-4000 / Vario-4000 Plus

Ordering details:

Article number

Max volume

(ml)

Vessel outer diameter

(mm)

Rack Capacity vials per rack

Max vials Vario-4000

Max vialsVario-4000 Plus

A59130 45 18 Standard rack 80 240 (3 racks à 80 vials) 400 (5 racks à 80 vials)A59131 7.5 10.5 Micro rack 125 375 (3 racks à 125 vials) 625 (5 racks à 125 vials)A59132 140 / 240 36 Prep rack 60 240 (3 racks à 60 vials) 300 (5 racks à 60 vials)A59133 80 26 Semiprep rack 39 117 (3 racks à 39 vials) 195 (5 racks à 39 vials)A59134 50 30 Falcon® rack 24 72 (3 racks à 24 vials) 120 (5 racks à 24 vials)

Rack specifications:

Page 32: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�26

Electrical valves

A5854

AWA30BH

SpecificationsControl LAN, RS-232, analog, keypadDimensions 105 x 100 x 185 mm (W x H x D), without valveDisplay LCD or Mobile Control (optional)Power supply external DC24V, 60 WAmbient conditions temperature range: 4 – 40 °C; 39.2 – 104 °F

air humidity below 90% humidity (non-condensing)GeneralDimensions valve diameter 47.5 mmWeight 1.86 kg, without valve

AZURA® Valve Drive V 2.1S Multiposition Multi-position valves are used for fraction collection, eluent selection or column switching. They have one port in a central position and one channel which connects the central port to one of the peripheral ports.

If more than one valve is needed for your application, it might be helpful two combine these as units in one stackable assistant ASM 2.1L.

A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 67.

valve drivevalve valve material connection bore size max. flowrate 6-port 10-port 12-port 16-port

none — — — — AWA10 n/a AWA20 AWA30

multiposition stainless steel / Vespel® 1/16" 0.3 mm 50 ml/min AWA11DA400 bar

n/a n/a n/a

stainless steel / Vespel® or POM-H-TF

1/16" 0.6 mm 100 ml/min AWA10BA 300 bar

n/a n/a AWA30BH 50 bar

PEEK / PPS 1/16" 0.6 mm 50 ml/min AWA10BB 200 bar

n/a n/a n/a

stainless steel / Vespel® or POM-H-TF

1/8" 1.2 mm 500 ml/min AWA10BC 300 bar

n/a AWA20BG 25 bar

n/a

PEEK / PPS 1/8" 1.2 mm 500 ml/min AWA10BD 200 bar

n/a n/a n/a

stainless steel / Valcon E2

1/4" 4.0 mm 1000 ml/min n/a A5850 7 bar

n/a n/a

PEEK / Valcon E2 1/4" 3.9 mm 1000 ml/min A5854 17 bar

n/a n/a n/a

column selection valve for 5 columns, bypass option and reverse flow

PEEK / Valcon E 1/16" 0.4 mm 50 ml/min n/a n/a AWB00FC 50 bar

n/a

AWA11DA AZURA® Valve Drive V 2.1S with 6-port multiposition valve, stainless steel, 1/16“, 400 barAWA10BA AZURA® Valve Drive V 2.1S with 6-port multiposition valve, stainless steel, 1/16", 300 barAWA30BH AZURA® Valve Drive V 2.1S with 16-port multiposition valve, stainless steel, 1/16“, 50 barAWA10BB AZURA® Valve Drive V 2.1S with 6-port multiposition valve, PEEK, 1/16"AWA10BC AZURA® Valve Drive V 2.1S with 6-port multiposition valve, stainless steel, 1/8"AWA20BG AZURA® Valve Drive V 2.1S with 12-port multiposition valve, stainless steel, 1/8“, 25 barAWA10BD AZURA® Valve Drive V 2.1S with 6-port multiposition valve, PEEK, 1/8“, 150 barA5850 VICI/VALCO Selector with 10-port mutliposition valve, stainless steel, 1/4“, 7 barA5854 VICI/VALCO Selector with 6-port multiposition valve, PEEK, 1/4“, 17 barAWB00FC Column Selection Valve VICI for 5 columns, 1 bypass, reverse flow, 12 ports, 1/16“, 50 bar

Variants

Ordering details:

Page 33: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�27

Electrical valves

Order sample loops on page 46.

Electrical valves for injections and/or switching tasks 2-position valves are used mostly for injections, but can be used for complex switching systems as well. All ports are located in periphericpositions. The channels always connect two of these ports.

If more than one valve is needed for your application, it might be helpful to combine these as units in one stackable assistant ASM 2.1L.

A variety of software control options is available: KNAUER offers various options for drivers. Detailed information on page 67.

valve drivevalve head valve head material connection bore size max. flowrate 6-port

none — — — — AWA10

2-position stainless steel / Vespel®

1/16" 0.3 mm 50 ml/min AWA11CA 400 bar

stainless steel / Vespel®

1/16" 0.6 mm 100 ml/min AWA10AA 300 bar

PEEK / PPS 1/16" 0.6 mm 50 ml/min AWA10AC 200 bar

stainless steel / Vespel®

1/8" 1.2 mm 500 ml/min AWA10AD 300 bar

PEEK / PPS 1/8" 1.2 mm 500 ml/min AWA10AE 200 bar

Specifications valve drivesControl LAN, RS-232, analog, keypadDimensions 105 x 100 x 185 mm (W x H x D), without valveDisplay LCD or Mobile Control (optional)Power supply external DC24V, 60 WAmbient conditions temperature range: 4 – 40 °C; 39.2 – 104 °F

air humidity below 90% humidity (non condensing)GeneralDimensions valve diameter 47.5 mmWeight 1.86 kg, without valve

AWA11CA AZURA® Valve Drive V 2.1S with 6-port 2-position valve, stainless steel, 1/16“, 400 barAWA10AA AZURA® Valve Drive V 2.1S with 6-port 2-position valve, stainless steel, 1/16“, 300 barAWA10AC AZURA® Valve Drive V 2.1S with 6-port 2-position valve, PEEK, 1/16“, 150 barAWA10AD AZURA® Valve Drive V 2.1S with 6-port 2-position valve, stainless steel, 1/8“, 300 barAWA10AE AZURA® Valve Drive V 2.1S with 6-port 2-position valve, PEEK, 1/8“, 150 bar

Ordering details:

Variants

Page 34: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�28

Manual valves

Order mounting brackets on page 47.

Order sample loops on page 46.

Manual injection and multi-position switching valve Switching and injection valves by KNAUER have impressive performance data and an outstanding long-term stability. The valve is equipped with a REED contact that is closed (magnetically controlled) during injection. The start signal can be easily started with an integrator or HPLC software. The sample loops are also suitable for partial filling due to the fact that they flow in the reverse direction when injected (filled). In turn, this aids in the minimization of peak broadening.

Specifications Manual ValvesValves 2-positionValve type manualValve head material stainless steel / PEEKRotor seal material Vespel® /PPSCapillary connection 1/16" / 1/8“Ambient conditions temperature range: 4 – 40 °C; 39.2 – 104 °F

air humidity below 90% humidity (non-condensing)GeneralDimensions valve diameter 47.5 mmWeight 0.36 kg

AVI26BC Manual 6-port 2-position valve, stainless steel, 1/16", 400 barA1357 Manual 6-port 2-position valve, stainless steel, 1/16", 300 bar A1358V1 Manual 6-port 2-position valve, PEEK, 1/16", 200 barA1359 Manual 6-port 2-position valve, stainless steel, 1/8", 300 barA1360V1 Manual 6-port 2-position valve, PEEK, 1/8", 200 bar

Ordering details:

valve head valve head material connection pressure bore size max. flowrate article number6 port 2-position stainless steel /

Vespel®1/16" 400 bar 0.3 mm 50 ml/min AVI26BC

stainless steel / Vespel®

1/16" 300 bar 0.6 mm 100 ml/min A1357

PEEK / PPS 1/16" 200 bar 0.6 mm 50 ml/min A1358V1stainless steel /

Vespel®1/8" 300 bar 1.2 mm 500 ml/min A1359

PEEK / PPS 1/8" 200 bar 1.2 mm 500 ml/min A1360V1

Page 35: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�29

Ultra high pressure valves

2-position and multi-position valveKNAUER’s well-known high pressure and ultra-high pressure pumps and detectors based on AZURA® technology are now accompanied by the next generation of high precision injection and switching valves, designed to operate at pressures up to 1200 bar. This new valve series is ideal for users requiring low delay volumes and high durability and high performance.

Specification valvesValves 2 position valve / multiposition valveValve type manual & for valve drive

(VICI valve drive, not compatible to V 2.1S)Valve head material diamond coated stainless steel Maximum pressure stability 1200 barBore Size 0.3 mmRotor seal material Vespel® Capillary connection 1/16"Ambient conditions temperature range: 4 – 40 °C; 39.2 – 104 °F

air humidity below 90% humidity (non-condensing)

Order mounting brackets on page 47.

AVI28AC Manual 6 port 2-position valve, DLC stainless steel, 1/16“, 1200 barAVI38AC Manual 8 port 2-position valve, DLC stainless steel, 1/16“, 1200 barAVC28AC 6 port 2-position valve w/o drive, DLC stainless steel, 1/16“, 1200 barAVC38AC 8 port 2-position valve w/o drive, DLC stainless steel, 1/16“, 1200 barAVR28AC 6 port multiposition valve w/o drive, DLC stainless steel, 1/16“, 1200 barAVR38AC 8 port multiposition valve w/o drive, DLC stainless steel, 1/16“, 1200 barAWB02 VICI valve drive

Ordering details:

Please note that for valves without manual lever, the VICI valve drive has to be ordered separately.

valve valve head material connection pressure bore size article numberManual 6 port 2-position DLC stainless steel /

Vespel®1/16" 1200 bar 0.3 mm AVI28AC

Manual 8 port 2-position AVI38AC6 port 2-position AVC28AC8 port 2-position AVC38AC6 port multiposition AVR28AC8 port multiposition AVR38AC

Order sample loops on page 46.

Page 36: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�30

Online degasser

AZURA® Degasser DG 2.1S Dissolved gases in the solvent can cause bubbles in the flow path of pumps and detectors.  Reliable chromatographic separation therefore requires degassing of the solvent. The small analytical 2-channel degasser AZURA® Degasser DG 2.1S is equipped with two degassing chambers and can thus degas two solvents simultaneously.

Key features

• Degassing of up to two eluents simultaneously

• Degasser nominal performance: 2ml/min per channel

• Small dead volume

• Needs very little bench space

Type degasser channels degasser maximum flow rate degassing chamber volume vacuum pump

AZE02 2 10 ml/min 285 µ per channel 1.37 mm (Hg /ml /min)

A5335 2 10 ml/min 480 µl per chamber 1.37 mm (Hg /ml /min)

A5328 2 50 ml/min 7.7 ml per chamber > 6.2 kPa : 400 cycles/min < 6.2 kPa : 60 cycles/min

Specifications

Degasser ModuleDegasser channels 2

Degasser maximum flow rate 10 ml/minDegassing method gas permeation through a fluoropolymer membrane

Dead volume approx. 285 µl per channelSolvent applicability universal, except hydrochloric acid and halogenated

hydrocarbons especially hexafluoro isopropanol (HFIP), hexane, heptane

Pressure decline 1.37 mm (Hg /ml /min)

Maximum pressure stability 7 barWetted materials Systec AF, PEEK, glass-filled PTFEDisplay 1 LED

GeneralDimensions 121 x 138 x 190 mm (W x H x D)Weight 2.3 kgPower supply 85 - 265 V, 50 - 60 Hz, 20 W

Ambient conditions temperature range: 4 - 40 °C, 39.2 - 104 °F

air humidity: below 90%, non-condensing

AZE02 AZURA® Degasser 2.1S analytical, 2 channels A5335 2-channel online GPC degasser, analytical, stand alone 480 µl dead volume Hexane compatibleA5328 2 channel online degasser, semi-preparative

Ordering details:

Feature overview for standalone devices

Page 37: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�31

Osmometer

K-7400S Semi-Micro Osmometer Freezing Point Osmometer KNAUER is one of the pioneers in the field of osmometry and known for its reliable and user friendly instruments for many decades. Our newest freezing point Osmometer K-7400S allows the easy and fast determination of the osmolality of various aqueous solutions. In addition, the freezing point depression of such samples can be measured.

The proven technology of freezing point determination in combination with the robust and intelligent design of the device allows fast and reproducible measurements. The instrument is equipped with a peltier cooler and an integrated microprocessor controlling the automated measurement.

The freezing point Osmometer is a standalone device that optionally can be equipped with a printer. Furthermore, the device can be controlled via the EuroOsmo 7400 software. The software automatically plots the temperature curve for each measurement and calibration and allows saving of the measured values. In addition, the data can optionally be exported into various file formats for archival storage.

Key features

• High precision measuring head - Made in Germany

• Variable sample volume between 50 and 150 µl

• Software EuroOsmo 7400 for control and data management

• Easy and fast measurement of solutes

• Small, quite and robust - Perfect for your lab

A0006AC K-7400S Semi-Micro OsmometerA0840-2 Measuring head for plastic sample tubesA3705 EuroOsmo 7400, control software for osmometer K-7400SA3711 Plain paper printer, with power supply

Ordering details:

Specifications

Sample volume 50 - 150 µlOsmolality range 0 - 2000 mOsmol/kgResolution 1 mOsmol/kgTest time ~ 2 minPrecision SD ≤ 4 mOsmol/kg [0 - 400 mOsmol/kg]

RSD ≤ 1 % [400 - 2000 mOsmol/kg]Linearity ± 1 % [0 -1500 mOsmol/kg]

± 1.5 % [0 - 2000 mOsmol/kg]Calibration Two-point Calibration (0 mOsmol/kg and one free selectable osmolality)

optional: Three-point Calibration (0 Osmol/kg and two free selectable osmolalities)CommunicationInterfaces RS-232 portControl Keypad (LED display, 2 rows with 24 characters)

optional: EuroOsmo7400 SoftwareGeneralDimensions 160 x 182 x 340 mm (W x H x D)Weight 4.5 kgPower supply 100 - 240 V, 50 - 60 Hz, 70 WAmbient conditions temperature range: 10 - 35 °C

air humidity: 20-80 %, non-condensing

Page 38: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�32

A9607 Mobile Control without data acquisition, including 10“ tablet, power supply and tablet mountA9608 Mobile Control Chrom with data acquisition, including 10“ tablet, power supply and tablet mountA9610 Mobile Control license without data acquisitionA9612 Mobile Control Chrom license with data acquisition A9614 Upgrade license Mobile Control to Mobile Control ChromA9617 Mobile Control Mount flexible tablet mount for 7-10“ tabletsA96181 USB-LAN ADAPTER Network adapter USB 2.0 <-> 10/100 Ethernet for tabletsA64809 WLAN Router, 8-port Gigabit RJ-45A64809INT WLAN Router with international power supply wo plug, 8-port Gigabit RJ-45A64811 Single device WLAN router for Mobile Control 1x RJ45, 10/100 MBit, WLAN, WLAN router for single device

System requirements

Operating system: Windows 10 Communication: WIFI or LAN Display size: minimum 10" Display resolution: 1024 x 768 or 1280 x 800 (optimized) RAM: 1 GB (Mobile Control), 2 GB (Mobile Control Chrom) Processor: 1.5 GHz, Dual-Core Disc space: 200 MB

Mobile Control (Chrom) for Windows 10 The Mobile Control (Chrom) is an intuitive, simple and cost-effective software solution for controlling and monitoring your KNAUER devices and systems. The friendly system overview provides instant insight into device and system status and allows you to adjust key parameters with your fingertips. The smart user management makes the Mobile Control safe; ensuring that device parameters only be changed by authorized operators. The graphical display of GLP data helps you avoid problems and unexpected downtime as well as to plan maintenance controls. With the hand-held Mobile Control option you can check your system remotely, allowing you to oversee multiple systems from the comfort of your office. Alternatively you can install the Mobile Control directly on your PC. Free updates enable you to take advantage of new devices. Your Mobile Control license can be easily upgraded to Mobile Control Chrom with data acquisition and analysis.

Ordering details:

Software

For a free demo version, please visit the KNAUER website: http://www.knauer.net/mobilecontrol

Supported devices on page 69.

Page 39: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�33

Software

ClarityChrom® ClarityChrom® is an easy-to-use Chromatography Data System for workstations. The optional extensions for GC control, PDA and GPC allow to use the software for a wide spectrum of application. Along to all KNAUER devices, devices and systems from more than 45 manufacturers are supported. The ClarityChrom® Prep includes the drivers for several fraction collectors and supports the peak recognition by level and/or slope. The manual fraction control and the option to use the KNAUER electric valves for fractionation gives you more flexibility. Due to the abundance of supported devices ClarityChrom® allows to update installed systems at a later state and even to operate in system hardware of different manufacturer. The software is in many language version available such as German, Russian, Chinese, French, Spanish, etc.

Package ClarityChrom®System architecture 32-bit CDSOperating system Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit;

Windows XP SP3 (32-bit only)Stand-alone workstation version, max. 4 systems controlled by one computer, max. 3

complete systems recommendedClient/server no client/server functionalityMulti-user environment

selectable system of user accounts with independently customizable behavior and appearance for individual users

Network environment easy offline data sharing (at the file level) among all stations in a local networkFields of application analytical and preparative HPLC, GPC/SEC, GC, MSInstrument connection supports RS-232, Ethernet, PCI interface card, A/D-D/A interfaceRecommended PC hardware

Pentium 2 GHz, 2 GB RAM, 4 GB RAM for DAD with high data rate, 20 GB free hard disk space, separate graphics card if one PC should control >1 system

Graphics capabilities multiple chromatogram view and overlay, PDA view

A1670* ClarityChrom® single instrument license for one time baseA1674* ClarityChrom® offline license for data evaluationA1671* ClarityChrom® additional instrument license on additional time baseA1676* ClarityChrom® option for PDA data processingA1681* Upgrade for one system from former version to ClarityChrom® or ClarityChrom® PrepA1685* ClarityChrom® Prep single instrument license for one time baseA1688* ClarityChrom® Prep offline license for data evaluationA1686* ClarityChrom® Prep additional instrument license on additional time baseA1677* System suitability optionA1678* Option for GPC data processingA1679* Option for MS data processingA1690 ClarityChrom® Prep Trial with 30 day Trial license dongle must send back after trial periodA1675* ClarityChrom® university package one offline license

Ordering details:

Specifications

* a sequential number is added to the article number which depends on the software version. At the time of printing,the current sequential number is -11 (e.g. A1670-11) for ClarityChrom® Version 7.2.

Integration 27 integration parameters (peak width, threshold, tangent slope ratio etc.) integration parameters programmable in time, automatic re-integration

Calculation types with/without calibration (int./ext. standard method)Security and GLP installation qualification test of the software; FDA 21 CFR Part 11 conformance, validation with virtual detectorInstrument control method-based instrument control, Instrument status display and direct control mode,Calibration 6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks), LOD, LOQChromatogram operations

overlay view, custom labels and settings, also applying mathematical operations to chromatograms

Automation sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – post run, batch

Presentation of results Integrated customizable table of results, columns with userdefined calculation, summary table, and export in text or database format

Calculations custom: 12 predefined mathematical operators, 15 basic and 4 summary functions, special: Kovats indexes for GC, determination of noise/drift, performance calculations

Data import & export ASCII, AIA, dBasePDA option 3D chromatogram, peak purity analysis, spectrum search in self-made or commercial spectra library (separate license

option)GPC/SEC option molecular weight determination in size exclusion chromatography with various calibration methods (separate license

option)System suitability test automates the calculation of system suitability parameters for system validation (separate license option)Supported devices on page 61.

Page 40: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�34

Software

PurityChrom® PurityChrom® is a chromatography software especially designed for purification and FPLC applications. PurityChrom® provides a very user friendly and clearly structured interface. The system visualization provides a graphical representation and easy handling of the complex flow processes. Furthermore, each device which is displayed in the fluidic scheme can be controlled manually. This provides the opportunity to change and adapt your conditions spontaneously during the run.

You have the option to create methods based on volume, column volume or time. The software allows you an exclusive monitoring of threshold values. This enables numerous programming possibilities, like peak fractionation, pressure monitoring and air bubble detection. The data analysis is intuitive and allows you to integrate peaks manually. Solvent visualization calculates the consumption of solvent for the current run and prevents your column from running dry. For fractionation, you can use a fractionation valve as well as a fraction collector.

Offline licenses are available for free on the KNAUER website: http://tinyurl.com/puritychrom

Package PurityChrom® Basic License: 8 devices (one modul counts except detectors) 3 data channels autosampler not supported Full license: no limitation in device number 8 data channels autosampler supported DAD license: 3D option

Operating system Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10Stand-alone for one system and one computerFields of application FPLC and Prep LCSupported instruments all KNAUER AZURA® devices, the Foxy® R1/R2 Fraction Collector

(see Release Notes) and many other devices, detailed information on requestInstrument connection supports RS-232, Ethernet, A/D-D/A interfaceRecommended PC hardware

CPU/Memory: Pentium III or higher with at least 1 MHz, 32 or 64 Bit at least 512 MB RAM (Windows XP) and 2 GB (Windows Vista and higher) graphics: Screen with minimal resolution 1024 x 768 connectors and Slots: USB for license dongle, COM, USB or LAN according to connected instruments

Integration real-time analysis of peaks, automatic or manual integration and baseline correctionSecurity and GLP FDA 21 CFR Part 11 conformanceAutomation sequencesPresentation of results individual report configurationCalculations column performance calculations according to DABData import and export comma Separated Value, AIA/ANDI, ChromStar SliceSpecial features method creation based on volume or column volume, hold function, functionalised

visualisation, direct control during a run, display of solvent supply, waste management

FRC option included

A2650 PurityChrom® Basic LicenseA2652 PurityChrom® Upgrade to full version inclusive autosampler optionA2654 PurityChrom® DAD License, for full version

Ordering details:

Specifications PurityChrom®

Supported devices on page 61.

PCs on page 37.

Page 41: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�35

Software

OpenLAB® CDS EZChrom Edition OpenLAB® CDS EZChrom Edition is the next generation of chromatography data systems and the successor of ChromGate® CDS. OpenLAB® CDS EZChrom Edition provides chromatography data acquisition, processing and control of GC and LC chromatographs and is used in chromatography operations ranging from single user/single instrument to multi-user/multi-instrument laboratories. It provides support of devices from KNAUER and many other manufacturers. The Shared Services module is the base of the OpenLAB® CDS architecture. The OpenLAB® Shared Services Control Panel allows for all administrative activities, as system and interface configuration, administration of users and built-in administrative reports, in a uniform interface. The OpenLAB® CDS EZChrom Edition offers advanced functionality with an interface known from the ChromGate® CDS. If you already work with ChromGate® or EZChrom Elite™, you will find the OpenLAB® CDS EZChrom Edition as a simple upgrade regarding usability and workflow. The basic workstation license can only be installed on one PC and allows for control and data acquisition from one system. The license includes System Suitability, Fraction Collector Control and one year Software Maintenance Agreement (SMA). OpenLAB® and EZChrom Elite™ are registered trademarks of Agilent Technologies, Inc.

Package OpenLAB® CDS EZChrom EditionSystem architecture 32-bit CDSOperating system workstation or client (A.04.06): Windows 7 Professional / Enterprise 32-bit and 64-bit, Windows 8.1

Enterprise or Professional 32-bit and 64-bit; Shared Services Server: Windows Server 2008 R2Stand-alone on a workstation max. 3 systems controlled by computer recommendedClient/server client/server functionality allows for using license keys from any computer in the network, full control

of a control-PC (server) from any other computer (Client) in the network (Distributed System)Multi-user environment allows to create users in the system with individual access management or to apply users from the

Windows domain or local PCNetwork environment runs on Windows networks based on TCP/IPFields of application analytical HPLC, preparative HPLC, GPC/SEC, GCInstrument connection supports RS-232, Ethernet, A/D-D/A interfaceRecommended PC hardware

workstation or client: Pentium 3 GHz, 4 GB RAM, 160 GB free hard disk space, separate graphics card ifone PC should control more than one system; Shared Services Server: Pentium 3 GHz, 4/6 GB RAM(32/64 bit), 160 GB free hard disk space

Graphics capabilities multiple chromatogram view and overlay, PDA view, arrange all open windowsIntegration real-time analysis of peaks, automatic or manual integration and baseline correctionCalculation types with/without calibration (int./ext. standard method)Security and GLP installation qualification test (IQ) of the software; FDA 21 CFR Part 11 conformance, validation of

integrationInstrument control method-based instrument control, Instrument status display and Direct-Control mode, Direct Control

can also be enabled for a runCalibration several types of calibration curves, unlimited number of levels, several reference and ISTD peaks

possible, groups, unlimited number of standards (peaks), LOD, LOQChromatogram operations overlay view, mathematical operations and smoothingAutomation sequences, Run Queue allows submitting of single runs and/or sequences, automatic launch of

selected commands, user programs or applications if the data acqusition is finished, post run, batchPresentation of results different report templates available, method custom report and advanced reports for individual

reports, new Intelligent Reporter allows for creating complex reports in a drag-and-drop editor with pre-configured tables, graphics and matrices, results can be shown in chromatogram

Calculations mathematical operations and smoothing, column performance calculations USP, DAB…Data import and export ASCII, ANDI (AIA) standard, OLE, ODBCSpecial features Direct Control during a run, pretreatment, stacked injectionFRC option always included, for preparative HPLC, adds tools for detector controlled fraction collection, solvent

and peak recyclingFRC features fractionation can be controlled by time (volume), level, slope including AND/OR combination of these

criteria, spectra comparison, local maximum and local minimum, slices, full manual control of fractionation during a run

PDA option 3D chromatogram, peak purity analysis, spectrum search in self-made or commercial spectra library (separate license option)

GPC/SEC option molecular weight determination in size exclusion chromatography with various calibration methods (separate license option)

System suitability test always included, automates the calculation of system suitability parameters for system validation

Specifications

Page 42: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�36

OpenLAB® CDS EZChrom Edition

Software

A2600-1 OpenLAB® CDS EZChrom Edition workstation for one system with SMA and 4x System Suitability

A2610-1 OpenLAB® CDS EZChrom Edition 3D option for UV detectors MW-1, 2550 and 2600 A2611-1 OpenLAB® CDS EZChrom Edition 3D UV Option for DAD DAD6.1L, DAD2.1L, PDA-1, S2850 A2618-01 OpenLAB® CDS EZChrom Edition drivers Sedex 80/85/90LT/LC not for fraction collection A2612-1 OpenLAB® CDS EZChrom Edition SEC/GPC option A2607-1 OpenLAB® CDS EZChrom Edition Workstation, Upgrade from ChromGate® 3.3.2 Standalone

with existing optionsA2601-1 OpenLAB® CDS EZChrom Edition Workstation license Right-to-copy, one additional system

with SMA and 4x SystemA2602-1 OpenLAB® CDS EZChrom Edition Instrument Control License A2614-1 OpenLAB® CDS EZChrom Edition for distributed systems - please ask for desired

configuration

Ordering details:

A1780* Thermo Scientific™ Dionex™ Chromeleon™ Bundle Workstation Open. Complete Software Package incl. License Dongle

A1782* Thermo Scientific™ Dionex™ Chromeleon™ Instrument Controller Option – Instrument Class 3. Max 2 LC per workstation

A1783* Thermo Scientific™ Dionex™ Chromeleon™ Driver CDA1784* Thermo Scientific™ Dionex™ Chromeleon™ Instrument Controller Option - 3D Data

Acquisition

Ordering details:

Thermo Scientific™ Dionex™ Chromeleon™ chromatography data system driver Thermo Scientific™ Dionex™ Chromeleon™ is one of the most wide-spread chromatography data systems. Its intuitive handling benefits laboratory workflow and the highly developed algorithms simplify data processing. It offers a broad range of third-party drivers and can be easily used with existing HPLC systems. KNAUER offers drivers for a lot of its devices.

Disclaimer: KNAUER Wissenschaftliche Geräte GmbH is solely responsible for development, testing and support of Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System driver software for KNAUER instruments and therefore solely liable for damages associated with the use of this driver software.

Computer requirementsOperating system Windows 8.1 Professional, 64-bit;Windows 7 SP1 Professional,

Enterprise, 64-bit, (32-bit version is not recommended); Windows Vista SP2 Business, Ultimate, 32-bit (Vista is not recommended)

CPU (recommended) 3 GHz Intel Core i7 or betterMemory RAM (recommended)

8 GB

Free Hard Disk Space 120 GB available, for system with PDA detectorsOptical Drive DVDDisplay (recommended) 1280 x 1024, 32-bit colorUSB Ports 1 port for USB license keyEthernet Port 1 port for router (for system connection)

Supported devices on page 61.

PCs on page 37.

Supported devices on page 61.

PCs on page 37.

* a sequential number is added to the article number which depends on the software version. At the time of printing,the current sequential number is -2 (e.g. A1783-2) for Thermo Scientific™ Dionex™ Chromeleon™ Version 7.2.

Page 43: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�37

PC hardware & IT accessories / power connections

CDS WorkstationA13110 Chromatography Workstation for PurityChrom® and ClarityChrom® with 24" monitor,

Windows 10, Intel® Core™ i5, 8 GB RAM, 256 SSD, two network cards, german editionA13111 Chromatography Workstation for OpenLAB® and Chromeleon™ with 24" monitor,

Windows 7, Intel® Core™ i7, 8 GB RAM, 256 SSD, two network cards, german editionA13112 Laptop for PurityChrom® and ClarityChrom®, Windows 10, Intel® Core™ i3, 8 GB RAM, 256

SSD, german editionA13113 Laptop for OpenLAB® and Chromeleon™,

Windows 7, Intel® Core™ i5, 8 GB RAM, 500 GB HDD, german editionA13114 Microsoft Surface Pro 4 for PurityChrom®, Windows 10, Core m3, 4GB RAM, 128 GB SSD,

german edition with keyboard, Surface Pen and docking station A13120 Chromatography Workstation for PurityChrom® and ClarityChrom® with 24" monitor,

Windows 10, Intel® Core™ i5, 8 GB RAM, 256 SSD, two network cards, international editionA13121 Chromatography Workstation for OpenLAB® and Chromeleon™ with 24" monitor, Windows

7, Intel® Core™ i7, 8 GB RAM, 256 SSD, two network cards, international edition

Power cablesM1642 Power cable for Europe, 2 m, with rubber connector type C13, 230 VM1597 Power cable for Switzerland, 2 m, with rubber connector type C13, 230 VM1278 Power cable for UK, 2.5 m, with rubber connector type C13, 230 VM1651 Power cable for USA, 2 m, with rubber connector type C13, 115 V M2651 Power cable, 1.5 m, with rubber connector for UPS APC Smart connectorAZS80SA Distribution Box 24 V for 6 devices like Air sensor, external pressure sensor, IFU 2.1 LAN

PC hardware & IT accessories

Configuration on requestA13130 PC, special edition on request

Network devicesA64809 WLAN Router, 8-port Gigabit RJ-45A64809INT WLAN Router with international power supply wo plug, 8-port Gigabit RJ-45A3119 8-port LAN GB Switch NetGear GS108GE 8x RJ-45, GBit, Auto-MDIX A3119INT 8-port LAN GB Switch NetGear GS108GE 8x RJ-45, Gigabit, Auto-MDIX power plug UK/US/

AUSA3126 5-port Fast Ethernet Switch NetGear FS105 5x RJ-45, 100 MBit A3126INT 5-port Fast Ethernet Switch NetGear FS105 5x RJ-45, 100 MBit power plug UK/US/AUS

IT accessoriesA3114 VSCOM USB 4 COM 4 x RS-232 DE9 on USBAZB00XA AZURA® Interface Box IFU 2.1 LAN, A/D converter, 4 channelsM0447V1 UK plug for WLAN router / SwitchM0447V2 US plug for WLAN router / SwitchM0447V3 AUS plug for WLAN router / SwitchA5255 Patch cable CAT5e RJ45/RJ45 3mA0895 RS232 f/f cable 9-pol nullmodemA0884 RS232 m/f cable 9-polA3121 APC Smart UPS 1500 VA, uninterruptible power supply

Page 44: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�38

Detailed information available via KNAUER website: http://tinyurl.com/columnkits

Column kits

BRP_KIT01 RP analytical Column Kit 5 µm, Eurospher II, 3 columns (C18, C18A, C8) 150 x 4 mm with integrated precolumn

BRP_KIT02 RP analytical Column Kit 3 µm, Eurospher II, 3 columns (C18, C18A, C8) 100 x 3 mm with integrated precolumn

BRP_KIT03 RP UHPLC Column Kit 2 µm, Eurospher II, 3 columns (C18, C18A, C8) 50 x 2 mm

BRP_KIT08 RP analytical Column Kit 3 µm, Eurospher II, 3 columns (C18H, C8, C18A) 150 x 4 mm ID

BRP_KIT09 RP analytical Column Kit 3 µm, Eurospher II, 3 columns (C18, C18P, C18A) 150 x 3 mm ID

BRP_KIT12 RP UHPLC Column Kit 2 µm, Eurospher II, 3 columns (C18, C8, C18A) 100 x 2 mm ID

BRP_KIT15 RP analytical column Kit 5 µm, Eurospher II, 3 columns (C8, C18, C18A) 250 x 4 mm ID with integrated precolumn

RP column kit

BMIX_KIT01 Mixed analytical Column Kit 5 µm, Eurospher II (C18, C8, NH2), 150 x 4 mm ID

BMIX_KIT02 Mixed analytical Column Kit 5 µm, Eurospher II (C18H, Phenyl, Si), 150 x 4.6 mm ID

BNP_KIT01 NP analytical Column Kit 5 µm, Eurospher II (Si, NH2, Diol) 150 x 4 mm with integrated precolumn

BNP_KIT02 NP analytical Column Kit 3 µm, Eurospher II (Si, NH2, Diol) 100 x 3 mm with integrated precolumn

BSEC_KIT01 SEC column kit aqueous, low MW: 0.1 - 100 kDa, PSS SUPREMA (3 x 1,000 A, 5 µm) 300 x 8 mm with precolumn 50 x 8 mm

BSEC_KIT02 SEC column kit aqueous, medium MW: 0.1 - 1,000 kDa, PSS SUPREMA (30 A, 2 x 1,000 A, 5 µm) 300 x 8 mm with precolumn 50 x 8 mm

BSEC_KIT03 SEC column kit aqueous, high MW: 0.1 - 3,000 kDa, PSS SUPREMA (100 A, 2 x 3,000 A, 10 µm) 300 x 8 mm with precolumn 50 x 8 mm

BSEC_KIT04 SEC column kit aqueous, ultrahigh MW: 0.1 - 30,000 kDa, PSS SUPREMA (3 x Ultrahigh, 10 µm) 300 x 8 mm with precolumn 50 x 8 mm

SEC column kit

BGPC_KIT01 GPC column kit in THF, low MW: 0.1 - 60 kDa, PSS SDV (3 x 1,000 A, 3 µm) 300 x 8 mm with precolumn 50 x 8 mm

BGPC_KIT02 GPC column kit in THF, medium MW: 0.1 - 1,000 kDa, PSS SDV (1,000 A, 100,000 A, 5 µm) 300 x 8 mm with precolumn 50 x 8 mm

BGPC_KIT03 GPC column kit in THF, high MW: 0.1 - 3,000 kDa, PSS SDV (1,000 A, 100,000 A, 1,000,000 A, 5 µm) 300 x 8 mm with precolumn 50 x 8 mm

BGPC_KIT04 GPC column kit in THF, ultrahigh MW: 0.1 - 30,000 kDa, PSS SDV (1,000 A, 100,000 A, 10,000,000 A, 10 µm) 300 x 8 mm with precolumn 50 x 8 mm

GPC column kit

NP column kit

Mixed column kit

Page 45: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�39

Pump accessories

A0285

A5830

AZZ00MB AZURA® HPLC mixer up to 100 MPa, 50 µl mixing volumeAZZ00MC AZURA® HPLC mixer up to 100 MPa, 100 µl mixing volumeAZZ00MD AZURA® HPLC mixer up to 100 MPa, 200 µl mixing volumeAZZ10ME AZURA® HPLC mixer up to 40 MPa, 250 µl mixing volume

(biocompatible)A5830 HyperShear Static Mixer, (1.5mL), high flow series, SSTA9853-8 Mounting bracket AZURA® L for Hypershear mixing chambers

Static mixers

AZC00 AZURA® Eluent tray E 2.1L for AZURA® devices with a capacity of 6 x 1 l bottles or 4 x 2.5 l bottles or 2 x 5 l bottles, (delivery without bottles)

A5325 Eluent supply bottle, 1 L bottle (borosilicate glass) with special round bottom for minimal eluent remainder, includes screw-type cap

A2056 250 ml Bottle for Piston Back FlushingA5324 Set of eluent supply bottles 4 x 1 L bottles (borosilicate glass) with special round

bottom for minimal eluent remainder, includes screw-type capA5324-1 Set of eluent supply bottles, 2 x 1 L bottles (borosilicate glass) with special round

bottom for minimal eluent remainder, includes screw-type capA5324-2 Set of eluent supply bottles, 4 x 1 L bottles (borosilicate glass) for Eluents and 1 x 250

ml bottle piston backflushingA70037 Set of eluent supply bottles, 3 x 2.5 L brown glass bottles (borosilicate glass) with

special round bottom for minimal eluent remainder, for preparative HPLC/FPLC, includes screw-type cap

A3374A3373A3373 Mobile Phase Filter, stainless steel, 2 µm, 1/8" pipe OD, suitable for all analytical HPLC

systems A3374 Mobile Phase Filter, stainless steel, 20 µm, 1/8" pipe OD, suitable for all analytical and

semi preparative HPLC systems, max. flow rate 100 ml/min A3364 Mobile Phase Filter, Biocompatible PE, 20 µm, 1/8“ pipe OD, suitable for all FPLC

systems, max. flow rate 500 ml/minA9650 AZURA® Tubing Kit with cap and inset, solvent filter inlet and fittings, 1 setA96507 AZURA® Tubing Kit bio with cap and inset, solvent filter inlet and fittings, 1setA9661 Filter Cartridge for pump P 6.1L, Titanium frit, 2 µm pore size. 50 ml/min maximum

flow, High capacity filter, 60 µl volume, 3 pcs.A96601 Filter Cartridge for pump P 6.1L, Stainless steel frit, 2 µm pore size. 10 ml/min

maximum flow, Volume optimized filter, 20 µl volume, 3 pcs

Solvent filters and pump inlet tubing

A3364

Eluent tray and bottles

A0285 Dynamic mixing chamber, stainless steel, analytical, 1/16“, up to 420 bar (42 MPa), 1740 µl mixing volume

A0581 Dynamic mixing chamber, stainless steel, preparative, 1/8“, up to 250 bar (25 MPa), 5.9 ml mixing volume

A0275 Dynamic mixing chamber, titanium, analytical, 1/16“, up to 420 bar (42 MPa), 1740 µl mixing volume

A70581 Dynamic mixing chamber, titanium, preparative, 1/8“, up to 250 bar (25 MPa), 5.9 ml mixing volume

A2515 Mixing chamber extension unit, 1 intermediate section, titanium, 4.8 ml, 3 screws 6 x 60 mm

Dynamic mixers

AZZ00MB & AZZ00MC

AZZ10ME

AZC00

A2056A70037 A5324 A5324-1 A5324-2

A96507

A9650

Page 46: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�40

Pump accessories

A9861 Pump head inlet for Pump AZURA® P 2.1L, 80P 3/8" (NPT), stainless steel

A9868 Pump head inlet AZURA® for Pump P 2.1L, Set, 1/2"-20 UNF, PEEK with CTFE (Kel-F) adapter, including tubing 1/4“ PTFE

A98611 Bushing inlet for AZURA® Pump P2.1L BlueShadow 80P adapter to 3/8" tube stubA98612 Bushing inlet for AZURA® Pump P2.1L BlueShadow 80P LPG binary to 3/8" tube stubA98613 Bushing inlet for AZURA® Pump P2.1L BlueShadow 80P LPG ternary to 3/8" tube

stubA58267 Male Connector, stainless steel, 1/4"Tube OD x 1/4" Male NPTA58268 Male Connector, stainless steel, 4 mm Tube OD x 1/4" Male NPTA58269 Male Connector, stainless steel, 1/8" Tube OD x 1/4" Male NPTA58202 Inlet-bushing kit 1/8" capillary, 10 ml pump heads (P 2.1S, P 4.1S, S1050, P 6.1L, 40P)A58203 Inlet-bushing kit 1/16" capillary, 10 ml pump heads

(P 2.1S, P 4.1S, S1050, P 6.1L, 40P)A58204 Inlet-bushing kit 1/8" capillary, 10 (ceramic) and 50 ml (all) pump heads (P 2.1S,

P 4.1S, S1050, P 6.1L, 40P)A58205 Inlet-bushing kit 1/16" capillary, 10 (ceramic) and 50 ml (all) pump heads (P 2.1S,

P 4.1S, S1050, P 6.1L, 40P)A58207 Tubing kit for pump head inlet AZURA® for 1/4''-PTFE tubing, for pump P 2.1L, 80P,

S1800, including solvent filter

A5822 Outlet-bushing kit 1/8“ pipe socket for pumps S1800, 80P and P 2.1LA7200 Adapter 1/8“external thread on 1/16“ internal thread, 2 pieces

Pump head inlet fittings

Pump head outlet fittings

A9861

A5390 Mini CORI-Flow (M13) Mass flow controller incl. mounting block, capacity: 0.2 - 50 ml/min

A5391 Mini CORI-Flow (M14) Mass flow controller incl. mounting block, capacity: 2 - 800 ml/min

A5393 Mini CORI-Flow (M13) Mass flow controller incl. mounting block, capacity: 0.2 - 50 ml/min, Profibus

A5394 Mini CORI-Flow (M12) Mass flow controller incl. mounting block, capacity: 0,03 - 3,3 ml/min

A5395 Mini CORI-Flow (M13) Mass flow controller incl. mounting block, capacity: 0.2 - 50 ml/min, Hastelloy

A5396 HI-TEC Bright display for Mini CORI-Flow mass flow controller (display, setpoint and counter)*analog and bus versions on request

Mass flow controllers*

A5390

Page 47: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�41

Pump accessories

A54123-1

AHB40 Pump head 10 ml, stainless steel AHB32 Pump head 10 ml, ceramic AHB32DA Pump head 10 ml, ceramic with Ti-bushingsAHB43 Pump head 10 ml, Hastelloy-C, for corrosive chemicalsAHC20 Pump head 50 ml, stainless steel AHC22 Pump head 50 ml, ceramic AHC23 Pump head 50 ml, Hastelloy-C, for corrosive chemicals

Replacement pump head AZURA® Pump P 4.1S & P 2.1S

AHB40CA

AHB40 Pump head 10 ml, stainless steel AHB32 Pump head 10 ml, ceramic AHC20 Pump head 50 ml, stainless steel AHC22 Pump head 50 ml, ceramicAHB40CA Pump head 10 ml, stainless steel, for high temperature dosing applicationsAHC20CA Pump head 50 ml, stainless steel, for high temperature dosing applications

Replacement pump head BlueShadow 40P

AHA60 Pump head 5 ml, stainless steel (1000 bar)AHB40 Pump head 10 ml, stainless steel AHB40BA Pump head 10 ml, stainless steel, for normal phase applications AHB40CA Pump head 10 ml, stainless steel, for high temperature dosing applicationsAHB32 Pump head 10 ml, ceramic AHB32DA Pump head 10 ml, ceramic with Ti-bushingsAHC20 Pump head 50 ml, stainless steel AHC20BA Pump head 50 ml, stainless steel, for normal phase applications AHC22 Pump head 50 ml, ceramic AHC23 Pump head 50 ml, Hastelloy-C, for corrosive chemicalsAHB43 Pump head 10 ml, Hastelloy-C, for corrosive chemicals

Replacement pump head AZURA® Pump P 6.1L

A4029-1 Pump head 100 ml, stainless steel A4029V1 Pump head 100 ml, titanium A4021-1 Pump head 250 ml, stainless steel A4021V1 Pump head 250 ml, titanium A4038-1 Pump head 500 ml, stainless steel A4022-1 Pump head 1000 ml, stainless steel A4022V1 Pump head 1000 ml, titanium

Replacement pump head AZURA® Pump P 2.1L / BlueShadow 80P

A06841 Check valve unit for 10 ml (AZURA® Pump P 4.1S/ P 2.1S, BlueShadow 40P)A06842 Check valve unit for 50 ml (AZURA® Pump P 4.1S/ P 2.1S, BlueShadow 40P)A068412 Check valve unit for (KEL-F) 10 ml pump head (AZURA® Pump P 4.1S/ P 2.1S,

BlueShadow 40P)A068422 Check valve unit for (KEL-F) 50 ml pump head (AZURA® Pump P 4.1S/ P 2.1S,

BlueShadow 40P)A068411 Check valve unit (spring-loaded) for 10 ml and 50 ml pump head (AZURA® Pump P 4.1S/

P 2.1S, BlueShadow 40P)A1122 Check valve unit for 100 ml and 250 ml pump head (AZURA® Pump P 2.1L, BlueShadow

80P)A1080 Check valve unit for 500 ml and 1000 ml pump head (AZURA® Pump P 2.1L, BlueShadow

80P)

Check valves

Page 48: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�42

Pump accessories / Autosampler accessories

A0638 Crimp neck vial set N11, clear, 1.5 ml, crimp caps aluminum, septa rubber/TEF colorless, 1,000 pcs. each

A0664 Accessory kit for autosampler with vials, caps, septum and pliers for opening and closing

A1585 Vial kit for preparative auto sampler with 10 ml vials and PE caps (1000 pcs.) A500501 Vial plate for 84x1.5ml and 3x10ml vials for 3950 autosampler A500502 Prep vial plate for 12x 10ml for 3950 Autosampler A50050 Vial plates for 1.5 ml vials for 3950 Autosampler 2 pcs. A50077 Sample loop 100 µl, Stainless Steel for AZURA® Autosampler 3950 A50078 Sample loop 10 µl, Stainless Steel for AZURA® Autosampler 3950 A50079 Kit for large injection samples for AZURA® Autosampler 3950, incl. injection syringe

1000 µl, sample loop 500 µlA64700 Sample needle kit for AZURA® Autosampler 3950 and AS 6.1L for SPARK valve 1/16’’M0355 Plunger replacement tip 250 ul M2644 Rotor seal (100MPa) for UHPLC valve 18KPSI M2868 Preventive Maintenance Kit A50052-1/A50053/A50053-1/AAA20AA/AAA21AA

Alias 3950 and AS6.1L- BIOM2869 Preventive Maintenance Kit A50060/A500601/A50070/A500701/AAA10AA/AAA11AA

Alias 3950 and AS 6.1L- 100MPaM3053 Alias 3950 and AS 6.1L rotor seal (70 MPa) M3054 Preventive Maintenance Kit A50080/A50081 /AAA00AA/AAA01AA

Alias 3950 and AS6.1L - 70MPa

Autosampler AS 6.1L

Autosampler accessories

A96423 Maintenance kit for AZURA® Pump P 4.1S & P 2.1S, AZURA® Pump P 6.1L, BlueShadow 40P, 10 ml pump head, including 1 set of gaskets, 2 piston rods, 2 sapphire backing rings, 2 O-rings

A96424 Maintenance kit for AZURA® Pump P 4.1S & P 2.1S, AZURA® Pump P 6.1L, BlueShadow 40P, 50 ml pump head, including 1 set of gaskets, 2 piston rods, 2 sapphire backing rings, 2 O-rings

A96425 Maintenance kit 100 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including 2 sets of gaskets, 2 piston rods, 2 springs

A96426 Maintenance kit 250 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including 2 sets of gaskets, 2 piston rods, 2 springs

A96427 Maintenance kit 500 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including 2 sets of gaskets, 2 piston rods, 2 springs

A96428 Maintenance kit 1000 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including 2 sets of gaskets, 2 piston rods, 2 springs

A58211 Rebuild-Kit for Pump AZURA® Pump P 2.1L and BlueShadow 80P (100ml/250 ml), Venting screw KEL-F, Check valve unit KEL-F, O-ring

A5821-1 Rebuild-Kit for AZURA® Pump P 4.1S & P 2.1S, 10 ml/min pump head., Venting screw KEL-F, Check valve unit KEL-F, O-ring (FFKM)

A5821-2 Rebuild-Kit for AZURA® Pump P 4.1S & P 2.1S, 50 ml/min pump head., Venting screw KEL-F, Check valve unit KEL-F, O-ring (FFKM)

Maintenance kits

Page 49: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�43

A4068-2

Detector accessories

A4042 Flow Cell UV, 3 mm, 2 µl, 1/16", stainless steel A4045 Flow Cell UV, 3 mm, 2 µl, 1/16", PEEK A4061V2 Flow cell UV, 10 mm 10 µl, 1/16", stainless steel, with heat exchanger optimized for

S2550A4061XB Flow cell UV, 10 mm 10 µl, 1/16", stainless steel, with heat exchanger one sided inlet

and outletAMB18 3mm, 2µl, 1/16", 300bar PressureProof Flow cell cartridge for AZURA® Detector

DAD/MWDAMC19XA 10mm, 2µl, 1/16", 50bar LightGuide Flow cell cartridge for AZURA® DAD/MWDAMC38 10mm, 10µl, 1/16", 300bar PressureProof Flow cell cartridge for AZURA® DAD/MWDAMD59XA 50mm, 6µl, 1/16", 50bar High Sensitivity LightGuide Flow cell cartridge for AZURA®

DAD/MWDA64150 UHPLC flow cell UV, 10 mm, 2.4 µl, 1/16" fiber optics for PDA-1 A64151 UHPLC flow cell UV, 50 mm, 10 µl, 1/16" LWL for PDA-1 A4069 Flow cell UV, 0.5 mm 1/16", stainless steel A4095 Flow cell UV, 0,5 mm 1/16", PEEK

Flow cells 1/16“

A4066 Flow Cell UV, 2 mm, 1/8", stainless steel, changeable to 0.5/1.25 mm A4067 Flow Cell UV, 2 mm, 1/8", PEEK, changeable to 0.5/1.25 mm

Flow cells 1/8“

A4068 Flow Cell UV, 2 mm, 1/4", stainless steel, changeable to 0.5/1.25 mm, without fittings

A4068-2 Flow Cell UV, 2 mm, straight connections, 1/4", stainless steel, changeable to 0.5/1.25 mm, without fittings

Flow cells 1/4“

A4061V2

AMC19XA

A4044

A4078

A4044 Flow cell UV, 3 mm, 2 µl, 1/16", stainless steel, double optic fiber connector A4044HT Flow cell UV, 3mm 2µl 1/16" SS High Temperature up to 85°C double optic fiber

connector -special version-AMKX8KIT Fiber optics adapter kit for AZURA® DAD/MWD A4047 Flow Cell UV, 3 mm, 2 µl, 1/16", PEEK double optic fiber connector A4074 Flow cell UV, 10 mm, 10 µl, 1/16", stainless steel, double optic fiber connector with

heat exchangerA4089 Flow cell UV, 0.5 mm 1/16", stainless steel double optic fiber connector A4096 Flow cell UV, 0.5 mm 1/16", PEEK double optic fiber connector

Flow cells 1/16“ fiber optics

A4078 Flow Cell UV, 2 mm, 1/8", stainless steel, changeable to 0.5/1.25 mm double optic fiber connector

A4079 Flow Cell UV, 2 mm, 1/8", PEEK, changeable to 0.5/1.25 mm double optic fiber connector

Flow cells 1/8“ fiber optics

A4104

A4104 Nano flow cell, 3 mm double optic fiber connector, fused silica, 375 µm OD capillary connection

Nano flow cell

Page 50: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�44

Detector accessories

A9843

A4152

A4081 Flow Cell UV, 2 mm, 1/4", stainless steel, changeable to 0.5/1.25 mm, double optic fiber connector

A4153 Special FlowCell, TriClamp1/4" 2mm, stainless steel 0.5/1.25/2 mm, fiber optical connector

A4152 Special FlowCell, TriClamp3/8" 2mm, stainless steel 0.5/1.25/2 mmm, fiber optical connector

A4152-1 Special FlowCell, TriClamp3/8" 2mm, stainless steel 0.5/1.25/2 mmm, fiber optical connector

A4154 Special FlowCell, TriClamp1/2" 2mm, stainless steel 0.5/1.25/2 mm, fiber optical connector

A4155 Special FlowCell, TriClamp3/4" 2mm, stainless steel 0.5/1.25/2 mmm, fiber optical connector

Flow cells >1/8“ fiber optics

A0740 Fiber optic cables (2 pc), 750 mm, 2x SMA 905 600/660, polymicro A0743 Fiber optic cables (2 pc), customer made sizes, polymicro SMA 905 600/660 A0740HT Fiber Optical Connectors (2pc) 750 mm, up to 85 °C Polymicro, FSMA 600/660 H+S

Fiber optic cables

A9842 Waste tubing kit LightGuide flow cells 1/16" A9843 Waste tubing kit UV flow cells 1/16" A9844 Waste tubing kit UV flow cells 1/8"

Waste tubing kits

A4071 Deuterium lamp, replacement, 35 W, original spare part A4447V1 Deuterium lamp, 35 W, for PDA K-2800, S-2800, S-2850 AZL01 Deuterium lamp type HBST for AZURA® DAD 6.1L A64210 HBST deuterium lamp kit for MW-1 and PDA-1 E²PROM Connector A5193 Deuterium lamp, replacement, for S2550, S2520, 10D 40D, 50D, UVD 2.1S, UVD

2.1L DAD 2.1L, MWD 2.1LA5194 Deuterium lamp type HBST for S2550 (-XA) and 50D (-XA) AZL02 Halogen replacement lamp for AZURA® DAD 6.1L A4073 Halogen lamp with base A4073XA Halogen lamp with base A64200 Halogen lamp kit for MW-1 E²PROM Connector SND A64201 Halogen lamp kit for PDA-1 E²PROM Connector SND A4072 Tungsten-halogen lamp adjusted A4072XA Tungsten-halogen lamp adjustedA4448 Tungsten-halogen lamp 7.5 W, with connector for TIDAS II adjusted, for PDA 2800

and PDA 2850A5195 Tungsten halogen lamp, replacement 2550 and 50D for 2-lamp version, original

spare partA5197 Tungsten halogen lamp, replacement 2550 for D2 lamp housing, original spare

partA07541 LED for Sedex 80 and 85A4142 Mercury vapor lamp with lamp bord, for WellChrom Fixed Wavelength Detector

K-200 A0753 Xenon lamp RF 10 AXL, 150 W A59210 Xenon lamp for RF-20A/Axs

Lamps

Page 51: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�45

Valve accessories

AVC28AC 2-position valve, 6-port, DLC stainless steel, Vespel®, 1/16", 1200 bar, 0.3 mm bore size

AVC38AC 2-position valve, 8-port, DLC stainless steel, Vespel®, /16", 1200 bar, 0.3 mm bore size

AVC26BC 2-position valve, 6-port, stainless steel, Vespel®, 1/16", 400 bar, 0.3 mm bore size,A1369 2-position valve, 6-port, stainless steel, Vespel®, 1/16", 300 bar, 0.6 mm bore sizeAVR28AC Multiposition valve, 6-port, DLC stainless steel, Vespel®, 1/16", 1200 bar, 0.3 mm

bore sizeAVR38AC Multiposition valve, 6-port, DLC stainless steel, Vespel®, 1/16", 1200 bar, 0.3 mm

bore sizeAVR26BC Multiposition valve, 6-port, stainless steel, Vespel®, 1/16", 400 bar, 0.3 mm bore sizeA1373 Multiposition valve, 6-port, stainless steel, Vespel®, 1/16", 300 bar, 0.6 mm bore sizeA1379 Multiposition valve, 16-port, stainless steel, POM-H-TF, 1/16", 50 bar, 0.6 mm bore

size

Valve head 1/16“ stainless steel

A1371 2-position valve, 6-port, stainless steel, Vespel®, 1/8", 300 bar, 1.2 mm bore sizeA1375 Multiposition valve, 6-port, stainless steel, Vespel®, 1/8", 300 bar, 1.2 mm bore sizeA1378 Multiposition valve, 12-port, stainless steel, POM-H-TF, 1/8", 25 bar, 1.2 mm bore size

Valve head 1/8“ stainless steel

A1370V1 2-position valve, 6-port, PEEK, PPS, 1/16", 150 bar, 0.6 mm bore sizeA1374V1 Mutliposition valve, 6-port, PEEK, PPS, 1/16", 150 bar, 0.6 mm bore size

Valve head 1/16“ PEEK

A1372 2-position valve, 6-port, PEEK, PPS, 1/8", 150 bar, 1.2 mm bore sizeA1376V1 Multiposition valve, 6-port, PEEK, PPS, 1/8", 150 bar, 1.2 mm bore size

Valve head 1/8“ PEEK

A1588 1 channel 1/16", POM-H-TF (50 bar)A1587 1 channel 1/8", POM-H-TF (25 bar)

A0880.3 1 channel, 1/16" and 1/8" PPS (200 bar)A0880 1 channel, 1/16" and 1/8" Vespel® (300 bar)

A0880.2 1 channel, 1/16" Vespel® (1200 bar)

A0880.1 1 channel, 1/16" Vespel® (400 bar)

A15801 3 channel 1/16", PPS (200 bar)

A15802 3 channel 1/8", PPS (200 bar)

A0611.2 3 channel, 1/16" Vespel® (1200 bar)

A0611 3 channel, 1/16" Vespel® (300 bar)

A0611.1 3 channel, 1/16" Vespel® (400 bar)

A0611.4 3 channel, 1/8" Vespel® (300 bar)

A0611.3 4 channel, 1/16" Vespel® (1200 bar)

A0880.4 8 Port 1 channel, 1/16" Vespel® (1200 bar)

Rotor seals

Page 52: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�46

Valve accessories

A0423

A1058

A0568

A0564

A1159-2

A05641 Sample Loop VICI,1 µL, stainless steel, 0.1 mm IDA05642 Sample loop,1 µl, stainless steel, 0.1 mm IDA05643 Sample loop, 2 µl, stainless steel, 0.1 mm IDA05644 Sample loop, 5µl, stainless steel, 0.25 mm IDA05645 Sample loop, 10 µl, stainless steel, 0.25 mm IDA05646 Sample loop, 20 µl, stainless steel, 0.25 mm ID A05647 Sample loop, 50 µl, stainless steel, 0.45 mm IDA05648 Sample loop, 100 µl, stainless steel, 0.45 mm IDA0565 Sample loop, 200 µl, stainless steel, 1 mm IDA0566 Sample loop, 500 µl, stainless steel, 1 mm ID A0567 Sample loop, 1000 µl, stainless steel, 1 mm ID A0568 Sample loop, 2000 µl, stainless steel, 1 mm ID A1054-2 KNAUER VariLoop S, variable injection volume and multiple injections,

movable piston protects against dilution, 10 ml, stainless steelA1055-1 KNAUER VariLoop L, variable injection volume and multiple injections,

movable piston protects against dilution, 40 ml, stainless steel

Sample loop stainless steel, 1/16“, incl. fittings

A1043 Sample loop, 1 ml, stainless steel, 2.2 mm IDA1044 Sample loop, 2 ml, stainless steel, 1.6 mm IDA0586 Sample loop, 5ml, stainless steel, 2.2 mm IDA0843 Sample loop, 10ml, stainless steel, 2.2 mm IDA1159-2 KNAUER VariLoop S, variable injection volume and multiple injections,

movable piston protects against dilution, 10 ml, stainless steelA1160-1 KNAUER VariLoop L, variable injection volume and multiple injections,

movable piston protects against dilution, 40 ml, stainless steel

Sample loop stainless steel, 1/8“, incl. fittings

A1058 Sample loop, 10 µl, PEEK, 345 bar, 0.25 mm IDA1060 Sample loop, 50 µl, PEEK, 240 bar, 0.7 mm IDA0508 Sample loop, 100 µl, PEEK , 240 bar, 0.7 mm IDA1061 Sample loop, 200 µl, PEEK, 240 bar, 0.7 mm IDA1057 Sample loop, 500 µl, PEEK, 240 bar, 0.7 mm ID A0423 Sample loop 1 ml, PEEK, 240 bar, 0.7 mm IDA0785 Sample loop 2ml, PEEK, 240 bar , 0.7 mm ID

Sample loop PEEK, 1/16“, incl. fittings

A78980 Bioline Sample Loop 5ml, PEEK, 50 bar, 1/8“ and 1/16“, 1.6 mm IDA78985 Bioline Sample Loop 10ml, PEEK, 50 bar, 1/8“ and 1/16“, 1.6 mm IDA1929 Superloop, 50 ml, variable injection volumes and multiple injections, movable piston

protects against dilution, 1/16“, Glass, 40 barA1928 Superloop, 150 ml, variable injection volumes and multiple injections, movable

piston protects against dilution, 1/16“, Glass, 20 bar

Sample loop PEEK, 1/8“, incl. fittings

Page 53: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�47

Valve accessories

A0723

A0653

A0723 Injection syringe 10 µl A0724 Injection syringe 25 µl A0725 Injection syringe 50 µlA0726 Injection syringe 100 µlA0727 Injection syringe 250 µlA0728 Injection syringe 500 µlA0729 Injection syringe 1000 µlA0730 Injection syringe 2500 µl

Injection syringes for 1/16“ injection port

A0573 Luer-Lock glass syringe, 10 ml A0653 Luer-Lock glass syringe, 20 ml

Luer-Lock glass syringes for 1/8“ injection port

A0555 Loop filling port A0328 Injection Port, stainless steel, 1/16“A03281 Injection Port, PEEK, 1/16“A0505 Injection Port, stainless steel, 1/8“A05051 Injection Port, PEEK, 1/8“

Loop filling ports

A9853-3 Mounting bracket AZURA® L for axial comp. column ID20 A9853-6 Mounting bracket AZURA® L for prep sample loop A9853-5 Mounting bracket AZURA® L for Knauer flow cells A9853 Mounting bracket AZURA® L for Knauer manual injection valves A9853-1 Mounting bracket AZURA® L for Vici manual injection valves A9853-2 Mounting bracket AZURA® L for Vici valve drives A9853-8 Mounting bracket AZURA® L for Hypershear mixing chamber A9854-1 Mounting bracket AZURA® L Bio for manual KNAUER injection valve, pH-flowcell and

2 prepacked columnsA9854-2 Mounting bracket AZURA® S for manual KNAUER injection valve

AZURA® mounting brackets

A0328

A0555

A9853

A9854-1

Page 54: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�48

Services / Qualification

VIQ_Inst IQ document for all instruments

Installation Qualification (IQ) - scope of delivery with all AZURA® instruments

VOQ_Pumps OQ Pumps AZURA®, Smartline, BlueShadow, Platinblue

VOQ_AS OQ Autosampler

VOQ_DAD OQ AZURA® DAD 6.1L, DAD 2.1L, MWD 2.1LVOQ_RF20 OQ RF20A/RF20AxsVOQ_RID OQ AZURA® RID 2.1L, Smartline S2300 VOQUVD21SA OQ AZURA® UVD 2.1SVOQUVD21LA OQ AZURA® UVD 2.1LVOQCM21SA OQ AZURA® CM 2.1S

VOQ_Flow OQ Flow Cells

VOQ_K7400 OQ K-7400VOQ_K7400S OQ K-7400S

VOQ_Valves OQ Valves

VOQ_FRC OQ for fraction collectors

VOQCT21A OQ AZURA® CT 2.1

VPV_001 AZURA® system with UV detectionVPV_002 AZURA® system with RID detection

Operation Qualification (OQ) - pumps

Operation Qualification (OQ) - autosampler

Operation Qualification (OQ) - detectors

Operation Qualification (OQ) - flow cells

Operation Qualification (OQ) - osmometer

Operation Qualification (OQ) - valves

Operation Qualification (OQ) - fraction collectors

Operation Qualification (OQ) - column thermostat

Performance Verification (PV)

Built in software

Installation Qualification (IQ) - software

VIQ_Inst

VOQ_Pumps

VOQ_FRC

VOQ_Valves

Page 55: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�49

Accessories – Fittings

!

!A0108 DYNASEAL connection system, 1/16", 4 short bushings, 4 clamping rings

and 8 sealing ringsA0181 DYNASEAL connection system, 1/16", 3 long bushings, 3 clamping rings

and 4 sealing ringsA1020 DYNASEAL connection system, 1/16", 10 short bushings, 10 biconical sealing rings A1069 DYNASEAL connection system, 1/16", 5 long bushings, 5 biconical sealing rings A0736 DYNASEAL connection system, 1/8", M8x1, 4 long bushings, 4 clamping rings

and 8 sealing ringsA0644 DYNASEAL connection system, 1/8", M8x1, 4 short bushings, 4 clamping rings

and 8 sealing rings

DYNASEAL system

A1021 Bushings for 1/16" capillaries, Dynaseal system, stainless steel, fingertight, short, 10 pcs.

A1064 Bushings for 1/16" capillaries, Dynaseal system, stainless steel, fingertight, long, 5 pcs.

A1067 Bushings for 1/8" capillaries, Dynaseal system, stainless steel, fingertight, short, 4 pcs.

A0735 Bushings for 1/8" capillaries, Dynaseal system, stainless steel, fingertight, long, 4 pcs.

Bushings for capillaries - DYNASEAL

A0484 4 Split-grooved clamping rings for capillaries with 1/16" OD A1239 4 Split-grooved clamping rings for capillaries with 1/8" OD A0482 100 Split-grooved clamping rings for capillaries with 1/16" OD

Split-grooved clamping rings

A0139 30 Sealing rings for capillaries with 1/16" OD, polymer A0140 100 Sealing rings for capillaries with 1/16" OD, polymer A1062 10 Sealing rings for capillaries with 1/16" OD, PEEK A0232 10 Sealing rings for capillaries with 1/8" OD, polymer A1063 10 Sealing rings for capillaries with 1/8" OD, PEEK

Sealing rings

A1070 10 Biconical sealing rings with 1/16", PEEK A1022 10 Biconical sealing rings with 1/16", polymer A0738 10 biconical sealing rings 1/8" PETP

Biconical sealing rings

K-Connect system

A9646 K-Connect Fingertight Fitting, PEEK, long, Set of 2, incl. ferrule, UNF 10/32 Thread for 1/16 inch K-Connect and PEEK Capillaries.

A9645 K-Connect Fingertight Fitting, Stainless Steel, long, Set of 2, incl. ferrules, UNF 10/32 Thread for 1/16 inch K-Connect Capillaries.

A9647 K-Connect Standard Fitting, Stainless Steel, Set of 2, incl. ferrule, UNF 10/32 Thread for 1/16 inch K-Connect Capillaries

A9647-1 K-Connect Standard Fitting, Stainless Steel, Set of 10, incl. ferrule, UNF 10/32 Thread for 1/16 inch K-Connect Capillaries.

Kits consisting of bushings, clamping and sealing rings

Kits consisting of bushings, clamping and sealing rings

A9646

A9645

A9647/A9647-1

A0108

A0181

A1020

A1069

A1021 A0735

A1064

A0482

A0484

A0139

A0140

A1022

Page 56: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�50

A5829 A58291

Accessories – Fittings

A58294A58292

A0733A0141

A25012A25011

A0830

A0112/A0113

A0110/A0111

A0112 10 Bushings for capillaries with 1/16" OD, stainless steel, wrench caliber 1/4", UNF 10-32, short

A0113 25 Bushings for capillaries with 1/16" OD, stainless steel, wrench caliber 1/4", UNF 10-32, short

A0115 3 Bushings for capillaries with 1/16" OD, stainless steel, wrench caliber 1/4", UNF 10-32, long

A0116 10 Bushings for capillaries with 1/16" OD, stainless steel, wrench caliber 1/4", UNF 10-32, long

Bushings for capillaries 1/16“, stainless steel

A0830 10 Bushings for capillaries with 1/8" OD, M8x1, wrench caliber 10, stainless steel

Bushings for capillaries 1/8“, stainless steel

A0110 30 Ferrules for capillaries with 1/16" OD, stainless steel A0111 100 Ferrules for capillaries with 1/16" OD, stainless steel A0874 10 Ferrules for capillaries with 1/8" OD, stainless steel A01101 10 Ferrules, Hastelloy, for capillaries with 1/16" ODA01102 10 Ferrules, Titanium, for capillaries with 1/16" OD

Ferrules for capillaries

A0141 Bushings for 1/16" capillaries, polymer, knurled, UNF 10-32, short, 10 pcs.A0142 Bushings for 1/16" capillaries, polymer, knurled, UNF 10-32, short, 30 pcs.A0144 Bushings for 1/16" capillaries, polymer, knurled, UNF 10-32, long, 10 pcs.A0145 Bushings for 1/16" capillaries, polymer, with integrated sealing cone, knurled,

UNF 10-32, short, 10 pcs.A0584 Bushings for 1/16" capillaries, PEEK, UNF 10-32, 10 pcs.A0733 Bushings for 1/8" capillaries, polymer, with integrated sealing cone, M8x1, knurled,

short,10 pcs.A25011 Bushing for 1/16" capillaries, PEEK, short Hex, with integrated sealing cone, 5 pcs.A25021 Bushing for 1/16" capillaries, PEEK, long Hex, with integrated sealing cone, 5 pcs.

Bushings for capillaries PEEK & polymer

A5829 Bushings flat bottom for 1/8" capillaries, PEEK, Super flangeless, 1/4-28, 10 pcs.A58291 Bushings flat bottom for 1/16" capillaries, PEEK, Super flangeless, 1/4-28, 10 pcs.A58292 Ferrules for 1/16" capillaries and flat bottom bushings, PEEK, with lock ring (stainless

steel), for Super flangeless bushings, 10 pcs.A58293 Ferrules for 1/8" capillaries and flat bottom bushings, PEEK, with lock ring (stainless

steel), for Super flangeless bushings, 10 pcs.A58294 Ferrules for 1/8" capillaries and flat bottom bushings, ETFE, with lock ring (stainless

steel), for Super flangeless bushings, 10 pcs.A1982 Adapter PEEK 1/16" external 10/32 thread on 1/8" flat bottom internal thread

A05841 Adapter PEEK 1/8" external thread on 1/16" flat bottom internal thread

Flat bottom fittings and adapters

A05841

A1982

A0115/A0116

Page 57: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�51

Accessories - Caps/connectors

A0117

A0146A0146 Blind fittings, 1/16", polymer, knurled, UNF 10-32, short, 10 pcs.A0147 Blind fittings, 1/16", polymer, knurled, UNF 10-32, short, 30 pcs.A0582 Blind fittings, 1/16", PEEK, knurled, UNF 10-32, short, 10 pcs.A0734 Blind fittings, 1/8", polymer, knurled, M8x1, short, 10 pcs.

Caps (blind fittings)

A0148 Low dead volume coupling to connect 2 capillaries with 1/16'' OD (material: PEEK/PETP, thread: UNF10-32), including 2 bushings and sealing rings, 1 pc.

A0149 Low dead volume coupling to connect 2 capillaries with 1/16'' OD (material: PEEK/PETP, thread: UNF10-32), including 2 bushings and sealing rings, 5 pcs.

A0233 Low dead volume coupling to connect 2 capillaries with 1/16'' OD (material: PEEK, thread: 10-32 UNF), including 2 one-piece PEEK fittings

A1407 Low dead volume coupling to connect 2 capillaries with 1/16'' and 1/8"OD (material: PEEK, thread: 10-32 UNF, M8x1), including 2 one piece fittings (1x 1/16", 1x 1/8")

A14071 Low dead volume coupling to connect 2 capillaries with 1/8"OD (material: PEEK, thread: M8x1), including 2 one piece fittings 1/8"

Low dead volume couplings, polymer/PEEK

A0117V1 Low dead volume coupling to connect 2 capillaries with 1/16'' OD (material: titanium, thread: 10-32 UNF), including 2 bushings and ferrules

A0117 Low dead volume coupling to connect 2 capillaries with 1/16'' OD (material: stainless steel, thread: 10-32 UNF), including 2 bushings and ferrules

A0118 Low dead volume coupling to connect 2 capillaries with 1/16'' OD (material: stainless steel, thread: 10-32 UNF), including bushings and ferrules, 5 sets

A0119 Low dead volume coupling to connect 2 capillaries with 1/16'' OD (material: stainless steel, thread: 10-32 UNF), including bushings and ferrules, 25 sets

A2512 Low dead volume coupling to connect 2 capillaries with 1/8" OD (material: stainless steel, thread: M8x1), including 2 bushings and ferrules

A2513 Low dead volume coupling to connect a capillary with 1/16" OD to a capillary with 1/8'' OD (material: stainless steel, thread: M8x1, 10-32 UNF)

A0485 Low dead volume coupling Dynaseal to connect a capillary with 1/16" OD to a capillary with 1/8'' OD (material: stainless steel, thread: M8x1, 10-32 UNF), including Dynaseal bushings and ferrules (1x 1/16", 1x 1/8")

A0480 Low dead volume coupling Dynaseal to connect 2 capillaries with 1/8" OD (material: stainless steel, thread: M8x1), including 2 Dynaseal bushings and ferrules

Low dead volume couplings, stainless steel/titanium

A0734

A0148

A0233

A2513

A58263 Union to connect 2 capillaries with 1/4" ODA58264 Reducer to connect a capillary with 3/8" OD to a capillary with 1/4'' ODA58265 Reducer to connect a capillary with 8 mm OD to a capillary with 1/4'' ODA58266 Reducer to connect a capillary with 1/8'' OD to a capillary with 1/4'' ODA58270 Reducer to connect a capillary with 1/16'' OD to a 1/8'' OD pipe A58271 Reducer to connect a capillary with 1/8'' OD to a 1/4'' pipe union A58271

A58270

A58264

A58265

A58266

A58263Unions and Reducing unions, stainless steel

Page 58: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�52

Accessories - Caps/connectors

A2511

A0150

A2511 T-connector to connect 3 capillaries with 1/8'' OD (material: stainless steel, thread: M8x1), including 3 bushings and ferrules

A0120 T-connector to connect 3 capillaries with 1/16'' OD (material: stainless steel, thread: 10-32 UNF), including 3 bushings and ferrules

A58260 T-connector to connect 3 capillaries with 1/8'' OD (material: stainless steel)A58261 T-connector to connect 3 capillaries with 1/4'' OD (material: stainless steel)A58262 T-connector to connect 3 capillaries with 1/4'' OD (material: titanium)

T-connectors, stainless steel /titanium

A0150 T-connector to connect 3 capillaries with 1/16'' OD (material: PETP/POM, thread: 10-32 UNF), inclusive 2 bushings and sealing rings

A2511-1 T-connector to connect 3 capillaries with 1/8'' OD (material: PEEK, thread: M8x1),including 2 one piece PEEK fittings 1/8"

T-connectors, polymer

A5800 Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (up to 50 bar), 1/8", stainless steel

A5800V1 Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (up to 50 bar), 1/8", titanium

A5801 Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (up to 25 bar), 1/8", stainless steel

A5802 Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (without spring), 1/4", stainless steel

A5805 Pressure release valve stainless steel, up to 3 bar, 1/16" connectorsM1070 Spring for pressure release valve, Series "R3A" 25 - 50 barM1080 Spring for relief valve Series "R3A" 3.4-24 bar M1258 Pressure relief valve tee for 1/16" OD Tubing, incl. fittings for 1/16"

Pressure release valves

A0121 X-connector to connect 4 capillaries with 1/16'' OD (material: stainless steel, thread: 10-32 UNF), including 4 bushings and ferrules

A1096 X-connector to connect 4 capillaries with 1/8'' OD (material: stainless steel, thread: M8x1), including 4 bushings and ferrules

A58272 X-connector to connect 4 tubings with 1/4'' OD (material: stainless steel, Swagelok) for 1000 ml/ min Systems

X-connectors, stainless steel

X-connectors, polymer

A0151 X-connector to connect 4 capillaries with 1/16'' OD (material: polymer, thread: 10-32 UNF), including 4 bushings and sealing rings

A0151

A1096

A58260

A58261

A58262

M1070

A70087 Back-Pressure Regulator for 1/16“ OD tubing, 10-32 threads, PEEK, Range 1-20 bar (15-300 psi)

A70088 Back-Pressure Regulator for 1/16“ OD tubing, 10-32 threads, PEEK, Range 20-103 bar (300-1500 psi)

A70084 Back-Pressure Regulator for 1/16“ OD tubing, 10-32 threads, stainless steel, Range 90-300 bar (1300-4200 psi)

A70082 Spare membranes for Back-Pressure Regulators A70084, A70087, A70088A5804 Back-Pressure Regulator for higher flowrates up to 220 ml/min, for 1/8" and 1/16"

OD tubing, 134 µl volume, PEEK, provides a constant back-pressure of 1.4 bar (20 psi), contains fittings for 1/8" and 1/16"

Backpressure regulators

A580*

A70087

A5804

M1080

Page 59: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�53

Accessories - Capillaries

1/32“ 1/16“

Amount ID LengthA0130 1 Capillary 0.10 mm 300 cm A0131 1 Capillary 0.25 mm 300 cm A0132 1 Capillary 0.50 mm 300 cm A0133 1 Capillary 0.70 mm 300 cm A0134 1 Capillary 1.00 mm 300 cm A0123 10 Capillaries 0.10 mm 10 cm A0124 10 Capillaries 0.10 mm 20 cmA0125 10 Capillaries 0.10 mm 30 cmA0126 10 Capillaries 0.25 mm 10 cmA0127 10 Capillaries 0.25 mm 20 cmA0128 10 Capillaries 0.25 mm 30 cm

Capillaries, stainless steel, 1/16"

Color code ID Length

AZF41 red 0.10 mm 150 mmAZF42 red 0.10 mm 300 mmAZF43 red 0.10 mm 400 mmAZF44 red 0.10 mm 700 mmAZF45 red 0.10 mm 900 mmAZF51 yellow 0.18 mm 150 mmAZF52 yellow 0.18 mm 300 mmAZF53 yellow 0.18 mm 400 mmAZF54 yellow 0.18 mm 700 mmAZF55 yellow 0.18 mm 900 mmAZF61 black 0.45 mm 150 mmAZF62 black 0.45 mm 300 mmAZF63 black 0.45 mm 400 mmAZF64 black 0.45 mm 700 mmAZF65 black 0.45 mm 900 mm

AZURA® Analytical K-Connect start-up kits, stainless steel, 1/32" capillaries with fitting sleeves for 1/16"connections. Sets include: 2 capillaries 150 mm, 2 capillaries 400 mm, 2 capillaries 700 mm, 1 Connector UNF 10/32 - UNF 10/32 stainless steel, 1 Connector UNF 10/32 - UNF 10/32 PEEK, 10 Wrench-tight fittings stainless steel, 2 Finger-tight fittings stainless steel, 2 Finger-tight fittings PEEK, 5 adapters for AZURA L-devices capillary guidance

A9849 AZURA® start-up kit 1/16" stainless steel, capillary kit A9849-1 AZURA® start-up kit 1/16", stainless steel, semi-prep, capillary kit A9850 AZURA® start-up kit 1/8" stainless steel, capillary kit AZF70 AZURA® start-up kit 1/16" stainless steel, capillary kit, 0.25 mm ID precut capillaries

AZURA® Capillary start-up kit, stainless steel

Capillaries, stainless steel, 1/8"Amount ID Length

A0639 1 Capillary 1.60 mm 150 cmA0640 1 Capillary 2.20 mm 150 cm

Capillaries, titanium, 1/16"

Color code IDAZF40 red 0.10 mmAZF50 yellow 0.18 mmAZF60 black 0.45 mm

Capillaries, AZURA® Analytical K-Connect, stainless steel, 1/32" with fitting sleeve for 1/16"connections

Amount ID LengthA0506 1 Capillary 0.70 mm 50 cm

Page 60: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�54

Accessories - Tubings

A70500 AZURA® FPLC Start-up kit, PEEK, 1/16" for 10 ml/min FPLC systemsA70500A AZURA® FPLC Start-up kit, transparent FEP, 1/16" for FPLC systems up to 10 ml/min

and 20 barA70600 AZURA® FPLC Start-up kit, PEEK/Tefzel, 1/16" for 50 ml/min FPLC systemsA70300 AZURA® FPLC Start-up kit, FEP/PEEK, 1/8" for 100 ml/min - 500 ml/min FPLC systemsA70300A AZURA® FPLC Start-up kit, PEEK, 1/8" for 100 ml/min - 500 ml/min FPLC systems, up to

100 bar.A70300B AZURA® FPLC Start-up kit, PEEK/Tefzel, 1/16" for FPLC systems up to 100 ml/minA70400 AZURA® FPLC Start-up kit, 1/4" for 1000 ml/min FPLC systems

Tubing start-up kits for FPLC

Color code ID max. pressureA2522 red striped 0.13 mm 420 barA2523 yellow striped 0.18 mm 400 barA2524 blue striped 0.25 mm 385 barA2525 orange striped 0.50 mm 350 barA2526 green striped 0.70 mm 240 barA2527 grey striped 1.0 mm 165 barA2528 black striped 1.4 mm 50 bar

PEEK tubing, 1/16", variable length, price per meter

ID Length max. pressureA0182 0.25 - 0.3 mm 300 cm 185 barA0183 0.7 mm 300 cm 115 barA01831 0.7 mm 1000 cm 115 barA04781 1.0 mm 300 cm 85 bar

Tefzel tubing, 1/16" OD

PTFE tubing, various OD

PEEK tubing, 1/8" OD, variable length, price per meter

Color code ID max. pressureA2540 natural 1.59 mm 220 barA2541 natural 0.75 mm 345 bar

A2542 natural 2.00 mm 165 bar

ETFE tubing, 1/8" OD

ID Length max. pressureA0478 1.6 mm 300 cm 70 bar

OD ID Length max. pressureA0152 1/16" (1.6 mm) 0.45 mm 300 cm 150 barA04782 1/16" (1.6 mm) 0.9 mm 300 cm n/aA0153 2 mm 1.5 mm 300 cm < 10 barA0732 1/8" (3.2 mm) 1.5 mm 300 cm 35 barA0873 3 mm 2.0 mm 300 cm n/aA0154 4 mm 3.0 mm 300 cm 20 barA1099 9 mm 7 mm 300 cm n/a

Page 61: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�55

Accessories - Inline filters / osmometry

A3381 Inline Filter (prep.) 5-10 µm, stainless steel, max. flow rate 1000 ml/min (for 1/8" tubing)

A33811 Replacement frit for A3381 5-10 µm, stainless steel, max. flow rate 1000 ml/min A00161 Inline Filter, PEEK body, Stainless steel frit, 1/16", to protect your column, with 2 µm

pore size, 3 pcs., easily connected directly to any columnB2 UHPLC/HPLC precolumn filter, universal, 0.5 µm titanium frit, set of 5, stainless steel

body, up to 1034 bar

Inline filters, stainless steel, for HPLC

A3378

A5811

A3378-1

A3378 Inline Filter, PEEK/Titanium, 1/16", biocompatible, to protect your column, with 2 µm pore size titanium frit

A3379 Inline Filter, PEEK/Titanium, 1/16", biocompatible, to protect your column, with 10 µm pore size titanium frit

A3378-1 Replacement Frits 2 µm for Inline Filter, PEEK/Titanium, biocompatible, for A3378A3379-1 Replacement Frits 10 µm for Inline Filter, PEEK/Titanium, biocompatible, for A3379A00162 Inline Filter, PEEK body, Titanium frit, 1/16", to protect your column, with 0.5 µm

pore size, 3 pcs.,easily connected directly to any columnA00163 Inline Filter, PEEK body, Titanium frit, 1/16", to protect your column, with 2 µm pore

size, 3 pcs., easily connected directly to any column

A5811 Shut-off valve, PEEK, 1/16", including connectors (1/4-28 flat bottom)A5812 Shut-off valve, PEEK, 1/8", including connectors (1/4-28 flat bottom)

A1980A1980 Luer Adapter to 10-32, ETFE, female Luer to male 10/32 threads for injection, simply screw the adapter in the port of your injection valve

Adapters

Inline filters, biocompatible, for FPLC

Shut-off valves

A00161/2/3

B2

A00161

A01240 Pack of 12 ampules NaCl calibrating solution, 300 mOsmol/kgA01241 Pack of 10 ampules NaCl calibrating solution, 400 mOsmol/kgA01250 Pack of 12 ampules NaCl calibrating solution, 850 mOsmol/kgA01248 Pack of 12 ampules NaCl calibrating solution, 2000 mOsmol/kgA02330 Cleaning tissue, lint-free, for thermistor cleaningA0840-2 Measuring head for plastic sample tubes

Osmometry accessories

A01241

Page 62: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�56

Accessories - Eluent and column heating / purification

A70053V1

A70092

A570XX

AZG10

A70085A70089

A70053V1 Eluent heating element 1/16" Capillary, 1mm ID integrated PT100 Temp.Sensor Temp. protect switch

A70054V4 Interface for temperature control and evaluation for A70053V1 2-channel temp. control for clean room

A70054V3 Interface for temperature control and evaluation for A70053V1 1-channel temp. control for clean room

A70058 Software for temperature control and logging A57024 Temperature controller for heating sleeve 2300 W (10 A) 230 VAC A57026 Heating sleeve for HPLC column 150 x 20 mm HM D=25..57*L=193 mm 100 °C,

230V, 200W, Pt100A57027 Heating sleeve for HPLC column 250 x 20 mm HM D=25..57*L=293 mm 100 °C,

230V, 200W, Pt100A57028 Heating sleeve for HPLC column 150 x 30 mm HM D=38..70*L=203 mm 100 °C,

230V, 400W, Pt100A57029 Heating sleeve for HPLC column 250 x 30 mm HM D=38..70*L=303 mm 100 °C,

230V, 500W, Pt100A57030 Heating sleeve for HPLC column 150 x 50 mm HM D=60..100*L=211 mm 100 °C,

230V, 500W, Pt100A57031 Heating sleeve for HPLC column 250 x 50 mm HM D=60..100*L=311 mm 100 °C,

230V, 800W, Pt100A57032 Heating sleeve for HPLC costum made up to 350 x 50 mm

High flow eluent and column heating devices

AZG10 Pressure Control for delta P measurement up to 250 ml/min with interface boxAZG10-1 External pressure sensor up to 250 ml/minAZG10-2 External pressure sensor up to 1000 ml/minA70092 Air sensor (1/16") for AZURA® Bio LC with one airsensor and wiring for up to 4

airsensorsA70092-1 Additional Air sensor for AZURA® Bio LC for 1/16" tubing A70093 Air sensor (1/8") AZURA® Bio LC with one airsensor and wiring for up to 4 airsensorsA70093-1 Additional Air sensor for AZURA® Bio LC for 1/8" tubing A70083 Air sensor (1/4“) for AZURA® Bio LC with one airsensor and wiring for up to 4

airsensorsA7083-1 Additional Air sensor for AZURA® Bio LC for 1/4" tubing AZS80SA Distribution Box 24 V for 6 devices like Air sensor, Pressure Control, IFU 2.1 LAN

A70085 AZURA® Organizer Holder for AZURA® Click for attaching falcons, columns (5 mm - 26 mm OD),

A70085-1 Clamp for AZURA® Organizer 16 mm A70085-2 Clamp for AZURA® Organizer 16 mm A70085-3 Clamp for AZURA® Organizer 25 mm A70089 AZURA® Click rail for AZURA® L devices for attaching IFU 2.1 LAN, airsensor,

pressure control

A5813 Flow splitter for use of CM 2.1S over 100 ml/min

Purification

AZG10-2

Page 63: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�57

Accessories - Vials / caps kits

A0637 Vials: Screw neck vials N8 (ø 11 mm), 1.5 ml, clear glass, flat bottom, small opening Caps: Screw Caps N8 PP, black with center hole Septa: PTFE white, thickness 0.25 mm 1000 pcs. each

A0637-1 Vials: Screw neck vials N8 (ø 11 mm), 1.5 ml, clear glass, flat bottom, small opening Caps: Ready assembled screw closures, septa are assembled, caps are ready-to-use, Screw Caps N8 PP, black with center hole Septa red rubber/FEP colorless 1000 pcs. each

A0637-2 Vials: Screw neck vials N8, (ø 11 mm), 1.5 ml, amber glass, with label field Caps: Screw Caps N8 PP, black, center hole, Septa: PTFE white, thickness 0.25 mm 1000 pcs. each

A0638 Vials: Crimp neck vials N11 (ø 11 mm), 1.5 ml, clear glass, wide opening, flat bottom, Caps: Crimp caps aluminium, center hole, ready assembled with septa rubber/TEF 1000 pcs. each

A0664 Vial kit for analytical autosamplers: Vials: Crimp neck vials N11 (ø 11 mm), 1.5 ml, clear glass, wide opening, flat bottom, Caps: Crimp caps aluminium, center hole, ready assembled with septa rubber/TEF 1000 pcs. each including pliers for opening and closing

Vials and caps kits for analytical HPLC

A0638-1 Vials: Screw neck vials N9 (ø 11 mm), 1.5 ml, amber glass, flat bottom Inlays: 0.3 ml glass micro inserts Caps: Screw caps blue with septum silicone white/PTFE red 100 pcs each

A0638-2 Vials: Screw neck vials N9 (ø 11 mm), 0.2 ml, amber glass, flat bottom, incl. integrated microinserts Caps: Screw caps blue Septa: Silicone white/PTFE red 100 pcs each

Vials and caps kits including microinserts for analytical HPLC

A1585 Vials: Crimp neck vials N20 (ø 22 mm), 10 ml, clear glass Caps: Cap PE transparent, N20 for flat crimp neck, center hole, Septa: Natural rubber red-orange/TEF, 1000 pcs. each

A15851 Vials: Crimp neck vials N20 (ø 22 mm), 10 ml, clear glass Caps: Cap PE transparent, N20 for flat crimp neck, center hole, Septa: Natural rubber red-orange/TEF, 100 pcs. each

Vials and caps kits for preparative HPLC

A0864 Closing pliers for crimpcaps, for ø 11 mm vialsA0865 Opening pliers for crimpcaps, for ø 11 mm vialsA1660 Closing pliers for crimpcaps, for ø 20 mm vialsA1661 Opening pliers for crimpcaps, for ø 20 mm vials

Pliers for analytical and preparative vials

A0637

A0637-1

A0637-2

A0638

A0664

A0638-1

A1585 A15851

A0864

A02721 Plastic sample tubes for Semi-Micro Osmometer K-7400S, 100 pcs.A0272 Plastic sample tubes for Semi-Micro Osmometer K-7400S, 500 pcs.A0720 Plastic sample tubes for Semi-Micro Osmometer K-7400S, 1000 pcs.

Sample tubes for osmometry

A02721 A0272 A0720

Page 64: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�58

Accessories - Tools

A0851

A1033

A0569 Tube cutter, suitable for all tubes A0851 Capillary cutter for PEEK capillaries and tubings with OD up to 4 mm A0809 Metal capillary cutting pliers for 1/16" capillariesA9865 Metal capillary cutter for 1/8" capillaries

Wrenches and tightening tools

Tool sets

A1033 Tool Kit AZURA® for systems with PEEK or pre-cut capillary kits A1033-1 Tool Kit AZURA® for 1/16" systems (stainless steel) A1033-2 Tool Kit AZURA® for 1/8" systems (stainless steel)

X0219 Torque wrench basic tool, 1-25 Nm, without plug-in head X0220 Open-jaw plug-in head 1-17 mm (for 100 - 1000 ml pump head in-/outlet and LPG-

block)X0221 Open-jaw plug-in head 1-10 mm (for Smartline I pump heads)X0222 Open-jaw plug-in head 1-13 mm (for 10 - 50 ml Smartline II/AZURA® pump heads

in-/outlet)X0003 Double open-end wrench, 1/4" and 5/16"X0030 Double open-end wrench, 8/10 mmA0138 Double open-end wrenches, 2 pc., 1/4"and 5/16"A25030 Tightening tools for PEEK fittings, blue, 1/16“ fittings 1/4“ hex head nut

(10-32 threads)A25031 Tightening tools for PEEK fittings, green, 1/32“ fittings 3/16 hex head nut

(6-40 threads)

Capillary and tube cutter

A0569

A9865

A9864

A9870

A0137

Capillary grater and bender

A0137 Capillary grater for degrating of 1/16" stainless steel capillaries, can also be used to remove column filters

A9864 Capillary grater for degrating of 1/8" stainless steel capillariesA9870 Tube bender for 1/8" and 3/16" tubings with an bend radius of 90°

X0219

X0030

A25030 A25031

A0809

Page 65: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�59

Accessories - Racks / column holder

A0070AA70190

A4363

A70010A1319

A70010 Benchtop rack: AZURA® L low 480 x 420 x 190 mm A70011 Benchtop rack: AZURA® L high 480 x 420 x 430 mm A70015 Benchtop rack: special manufacture with customized dimensionsA9860 Product Riser AZURA®: Set of 4 feet that lift the device to a height of 28 mm for easy handling of the

waste tube of the drainage system

LC racks

A9847 Column holder: Magnetic clip, for all columns with 1/4" OD, for all KNAUER columns with 3, 4 and 4.6 mm ID, compatible with all AZURA® devices

A3983 Prism column holder for horizontal storage of HPLC columns on the lab bench, the most price attractive alternative to store your HPLC columns

A1319 Glass column holder, Stand, plate and 2 clamps, can hold one glass column in the dimensions of 10-40 mm ID

A70190 Multi Column Base Bio 60 x 40 x 130cm (w x d x h) for up to 3 MPLC columns with conn. for coolingdevice

A0070A Multi Column Base serves as a holder for up to 3 columns with inner diameter up to 50 mm, especially made for preparative column solutions

LC column holder/Multi column base

A1071 HPLC Standard accessory kit A9862 Installation Box Kit, Box for small parts, KNAUER file folder and support sticker

A9860 A9847 A3983

A2820

Installation Accessories

A0714A 4-finger clamps, long shaft finger with silicone coating ø12mm clamp width 35-100 one pieceA4363 4-finger clamps, short shaft finger with silicone coating ø12mm clamp width 35-100 one pieceA4368 Clamp for Multi Column Base, short shaft, to fix an HPLC column or other accessories to the Multi

Column BaseA2820 Clamp for Multi Column Base, long shaft, to fix an HPLC column or other accessories to the Multi

Column BaseA2820A Bosshead squared for Multi Column Base, used in combination with clamps with a long shaft

Accessories for LC column holder

A2820A

A1071

A9862

Page 66: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�60

Applications & Academy

AL0200 HPLC Application Development, at KNAUER in BerlinAL0100 HPLC Method Transfer & Optimization, at KNAUER in BerlinAL0700 Rent an Expert - Application Support, at customers siteAL0510 HPLC Troubleshooting Workshop, at KNAUER in BerlinAL0520 HPLC Basics Workshop, at KNAUER in BerlinAL0500 Academy Individual Workshop, at KNAUER in Berlin

Ordering details:

Academy HPLC trainings and specialized courses for beginners and experienced users.

With profound application knowledge of analytical and preparative HPLC and FPLC, our team is at your service around the world. Our experts are pleased to receive your inquiries and requests, and will offer attractive customized solutions. Visit our website for more information: http://www.knauer.net/service

Rent an expert Rent an expert for assistance in your lab.

Method transfer & optimization Transfer your methods to one of our HPLC systems or make your analyses faster, more efficient and cost effective.

Application development Proof of concept and support in selecting a HPLC / FPLC method for your separation task.

Science projects KNAUER is involved in different research projects. Contact us for requests.

Investigation KNAUER participates in different research projects.

Page 67: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�61

Supported devices

The following data has been retrieved on 07/17/2017. For up-to-date information, please visit the KNAUER website: http://tinyurl.com/supporteddevices The tables list the software package and driver version (in case multiple versions exist); the version number listed is the first version that supports the respective device. Limitations are marked with superscript, e.g. 1). “n/a” means, that a device is not supported, “-“ that no information is available. If a device is supported by different communication ports, the desired port must be selected in the device directly. For some time, ChromGate® was also available as “PLATINblue Edition” for the PLATINblue devices, while the standard version is named as “regular”. From driver version 2825 all drivers are available in the regular version; the PLATINblue Edition was discontinued. OpenLAB® CDS EZChrom Edition version number lists Shared Service version and EZChrom version. KNAUER OEM devices are not supported by the KNAUER drivers.

Device support in KNAUER CDS / KNAUER device support in 3rd party software

OpenLAB® CDS EZChrom Edition / ClarityChrom® / Chromeleon™ / ChromGate® / PurityChrom®

Pumps OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version and Driver version

ChromGate® CDS version and Driver Version

PurityChrom

AZURA® Pump P 6.1L OLEE A.01.05/ A.04.05 Driver 1022

CC 5.0.2 Driver 4095 1)

Cm 7.2 Regular Class 3

driver 1)n/a Version: 5.07.039 1)

AZURA® Pump P 2.1L OLEE A.01.05/ A.04.05 Driver 1017

CC 3.0.7 Driver 3078 1)

Cm 7.2 Regular Class 3

driver 1)Cm 6.8 Generic driver 2)

CG 3.3.2 Driver 2825 3)

Version: 5.07.039 1)

AZURA® Pump P

2.1S/P 4.1S 6)OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3078 Cm 6.8 Generic driver 2)

CG 3.3.2 Driver 1787 Version: 5.07.039

PLATINblue Pump P-1

OLEE A.01.05 / A.04.05 Driver 1017

CC 5.0.3 Driver 4102 Cm 6.8 SR10 Regular Class 3 driver

CG 3.3.2 PLATINblue Edition 1751; Regular 2825

n/a

Smartline Pump 1050 4)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.6.5 Driver 1100 Cm 6.8 SR10 Regular Class 3 driver

CG 3.3.2 Driver 1751 Version: 5.07.039

Smartline Pump 1000 n/a CC 2.4.4 Cm 6.8 Generic driver 2)

CG 3.1 n/a

Smartline Pump 100 5), 6)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.6 Cm 6.8 Generic driver 2)

CG 3.3.1 Driver 1640 Version: 5.07.039

Preparative Pump 1800 (also WellChrom K-1800)

n/a CC 2.6 n/a CG 3.1 n/a

WellChrom Pump K-1001

n/a CC 2.6 n/a CG 2.55 7) n/a

WellChrom Pump K-1000

n/a CC 2.6 n/a CG 2.55 (not suppor-ted in version 3.1) 8)

n/a

WellChrom Pump K-501 9)

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom Pump K-120

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom Pump K-1001

n/a CC 2.6 n/a CG 2.55 7) n/a

BlueShadow Pumps 10P/20P 6)

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3078 Cm 6.8 Generic driver 2)

CG 3.3.2 Driver 1787 Version: 5.07.039

BlueShadow Pump 40P 10)

OLEE A.01.05 / A.04.05 Driver 1022

CC 5.0.2 Driver 4095 n/a n/a Version: 5.07.039

BlueShadow Pump 80P 10)

OLEE A.01.05 / A.04.05 Driver 1022

CC 5.0.2 Driver 4095 Cm 6.8 Generic driver 2)

n/a Version: 5.07.039

Page 68: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�62

Pumps OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version and Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

Kontron Pumps 320/322/325

n/a CC 3.0.5 11) - CG 3.1.7 Driver 446 12)

n/a

Kontron Pumps 420/422/425

n/a CC 3.0.5 11) - CG 3.1.7 Driver 446 12)

Version: 5.07.039

Kontron Pumps 520/522/525

n/a CC 3.0.5 11) - CG 3.1.7 Driver 446 12)

n/a

1) constant Pressure Mode / Isobar Mode is not supported

2) generic drivers do not support all of the devices features (e.g. no Isobar Mode); only control via RS-232; should also work with Chromeleon™ 7.x

3) support of RS-232 port from driver version 2844 4) for control via RS-232 only baud rate of 115200 is supported

5) can be controlled as pump K-120 only via RS-232 without pressure sensor in former software versions6) to set a static IP address a 3rd party tool is required

7) from ChromGate® version 3.1 only with firmware version 5.xx or higher;pumps with firmware up to version 4.XX must be configured as K-1000

8) from ChromGate® version 3.1 no pressure information; also K-1001 with firmware up to version 4.XX, no pressure trace

Detectors (for all PDA or scanning UV detectors the 3D license option is required to acquire and review the scan (3D) data)

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version and Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

AZURA® Detector UVD 2.1L 1)

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3078 Cm 7.2 Regular Class 3 driver; Cm 6.8 Generic driver 5)

CG 3.3.2 Driver 2825 n/a

AZURA® Detector MWD 2.1L

OLEE A.01.05 / A.04.05 driver 2068

CC 5.0.5 Driver 5011 Cm 7.2 Regular Class 3 driver

n/a Version: 5.07.067 15)

AZURA® Detector UVD 2.1S 2)

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3055 n/a CG 3.3.2 Driver 1787 Version: 5.07.039

AZURA® Detector DAD 6.1L

OLEE A.01.05 / A.04.05 driver 2047

CC 5.0.5 Driver 4110 Cm 7.2 Regular Class 3 driver

n/a Version: 5.07.102 16)

AZURA® Detector DAD 2.1L

OLEE A.01.05 / A.04.05 driver 2068

CC 5.0.5 Driver 5011 Cm 7.2 Regular Class 3 driver

n/a Version: 5.07.102 16)

AZURA® Detector RID 2.1L

OLEE A.01.05 / A.04.05 Driver 2092

CC 6.0.1 Driver 5037 (compatible with CC/CCP 5.x versions)

Cm 7.2 Regular Class 3 driver

n/a Version: 5.08.024 17)

AZURA® Conductivity Monitor CM 2.1S 2)

OLEE A.01.05 / A.04.05 driver 1022

CC 5.0.2 Driver 4095 n/a Generic Driver June 2013 5)

Version: 5.07.039 18)

PLATINblue Detector MW-1 3)

OLEE A.01.05 / A.04.05 Driver 1017

CC6.1.0; Driver 5015 Cm 6.8 SR10 Regular Class 3 driver

CG 3.3.2 PLATINblue Edition 1751; Regular 2825

n/a

PLATINblue DAD PDA-1

OLEE A.01.05 / A.04.05 Driver 1017

CC 5.0.2 Driver 4095 4)

Cm 6.8 SR10 Regular Class 3 driver

CG 3.3.2; PLATINblue Edition 1751; Regular 2825

n/a

Smartline UV Detector 2500 6)

n/a CC 2.4.4 Cm 6.8 Generic driver 5)

CG 3.1 Version: 5.07.039

Smartline UV Detector 2520 3), 7)

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.5 Driver 3033 n/a CG 3.3.2 Driver 1751 n/a

Supported devices

Page 69: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�63

Detectors (for all PDA or scanning UV detectors the 3D license option is required to acquire and review the scan (3D) data)

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version and Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

Smartline UV Detector 2550 3), 7)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.6.5 Driver 1079 Cm 6.8 SR10 Regular Class 3 driver

CG 3.3.1 Driver 1640 n/a

Smartline UV Detector 2600

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.4.4 Cm 6.8 Generic driver 5)

CG 3.1 Version: 5.07.039

Smartline UV Detector 200

n/a CC 2.6 n/a CG 3.1.7 Driver 1466 n/a

Smartline PDA Detector 2800

n/a CC 2.4.4 n/a CG 3.1.7 Driver 446 n/a

Smartline PDA Detector 2850

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.6.5 Driver 1100 n/a CG 3.3.2 Driver 1751 n/a

Smartline RI Detector 2300

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.4.4 n/a CG 3.1 n/a

Smartline RI Detector 2400

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.4.4 n/a CG 3.1 n/a

Smartline Conductivity Monitor S2900

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3055 n/a Generic Driver September 2010

n/a

WellChrom UV Detector K-2000 8)

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom UV Detector K-2001

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom UV Detector K-2500 8)

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom UV Detector K-2501 6)

n/a CC 2.6 n/a CG 2.8

WellChrom UV Detector K-2600

OLEE A.01.05 / A.04.05 Driver 2026

CC 2.6 Cm 6.8 Generic driver 5)

CG 2.55 n/a

WellChrom PDA Detector K- 2700 9)

n/a PCI / LAN n/a CG 2.55, LAN from 3.1

n/a

WellChrom PDA Detector K- 2800 9)

n/a PCI / LAN n/a CG 2.8, LAN from 3.1 n/a

WellChrom RI Detector 2300

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom RI Detector 2301

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom RI Detector 2400

n/a CC 2.6 n/a CG 2.8 n/a

WellChrom RI Detector 2401

n/a CC 2.6 n/a CG 2.8 n/a

Shimadzu fluorescence detector RF-10Axl 10)

n/a CC 2.6 n/a CG 3.1 Version: 5.08.024

Shimadzu fluorescence detector RF-20A/Axs with CBM-20

Shimadzu Control with official Shimadzu driver via CBM 20; requires special license, driver not developed byKNAUER

CC 7.2.0, only LC-10 functionality, driver developed by Data Apex

Cm 7.2 with official Shimadzu driver via CBM 20; requires special license, driver not developed by KNAUER

n/a n/a

Virtual Detector OLEE A.01.05 / A.04.05 Driver 1017

CC 2.6.5 Driver 1079 n/a CG 3.1.6 n/a

BlueShadow Detector 10D 3)

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3055 n/a CG 3.3.2 Driver 1787

Version: 5.07.039

BlueShadow Detector 40D 3), 7

OLEE A.01.05 / A.04.05 driver 1022

CC 5.0.2 Driver 4095 n/a n/a n/a

Supported devices

Page 70: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�64

Detectors (for all PDA or scanning UV detectors the 3D license option is required to acquire and review the scan (3D) data)

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

Antec Leyden LC-EC Detector Decade

n/a supported by Data Apex; CC 5.0.2

Cm 6.8 (driver not developed by KNAUER)

n/a Version: 5.07.039

Alltech Conductivity Detector 650

n/a n/a n/a CG 3.1.7 Driver 446 n/a

Kontron UV Detector 332/335 8), 12)

n/a supported by DataApex; CC 5.0.2

- CG 3.1.7 Driver 446 n/a

Kontron UV Detector 430/430A/432/435 8), 12)

n/a supported by DataApex; CC 5.0.2

- CG 3.1.7 Driver 446 n/a

Kontron UV Detector 530/532/535 8), 12)

n/a supported by DataApex; CC 5.0.2

- CG 3.1.7 Driver 446 n/a

Kontron DAD 540(/545) 12)

n/a supported by DataApex; CC 5.0.2

- CG 3.1.7 Driver 1466 n/a

Sedere Sedex ELSD 80/85LT

supported, driver was developed by MayLab Analytical 13)

supported by DataApex; CC 3.0.5

n/a (Cm 6.8) supported, driver was developed by MayLab Analytical 14)

Version: 5.07.039

Sedere Sedex ELSD 90LT

supported, driver was developed by MayLab Analytical 13)

supported by DataApex; CC 5.0.2

n/a (Cm 6.8) supported, driver was developed by MayLab Analytical 14)

Version: 5.07.039

Sedere Sedex LC supported, driver was developed by MayLab Analytical 13)

supported by DataApex; CC 5.0.2

n/a (Cm 6.8) n/a Version: 5.07.039

ERC RefractoMax 520 series

n/a supported by DataApex; CC 6.1.0, RS-232

Supported in Cm 7.2 (driver not developed by KNAUER)

n/a n/a

Antec Decade II n/a supported by DataApex; CC 5.x, RS-232

n/a n/a n/a

Antec Decade Elite n/a supported by DataApex;CC 5.X, USB, LAN

n/a n/a n/a

Grace/Alltech ELSD 3300

- supported by DataApex; CC 5.x, LAN

- Separate, license-free driver upon request or from Grace webpage, driver was developed from Grace/Alltech

-

1) only LAN is supported

2) to set a static IP address a separate tool is required

3) via RS-232 the maximum data rate is limited to 10 Hz 4) in ClarityChrom® 5.0.2, runs with data rates >10 Hz may not be stored with 3D data; recommended maximum data rate is 10 Hz, fixed in later versions

5) generic drivers do not support all of the devices features; only control via RS-232, data acquisition requires A/D

converter; should also work with Chromeleon™ 7.x 6) a trigger on Start input also starts the internal wave length program

7) for control via RS-232 only baud rate 115200 is supported 8) device only supports data acquisition via RS-232, no wavelength control

9) LAN only via separate LAN adapter A4442; default communication adapter is PCI interface card for RS-422, PCI interface card requires a PCI slot on the computer; driver for PCI interface card only works with Windows NT/2000, Windows XP or Windows 7

32-bit. 10) RS-232 only, maximum data rate 0.5 Hz, A/D converter for higher data rates required; special RS-232 cable required (KNAUER part number G0743)

Supported devices

Page 71: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�65

11) RS-232 only, special firmware version 0.90 required, feature set of RF-10 AXL only (1 channel only, no flow cell

temperature control, no scan), maximum data rate 5 Hz, A/D converter for higher data rates required; special RS-232 cable required (KNAUER part number G0743)

12) special RS-232 cable is required

13) driver must be installed separately and is protected with a separate USB dongle, detector cannot be used for fractionation;

KNAUER driver part number A2618-01 14) driver must be installed separately and is protected with a separate USB dongle, detector cannot be used for fractionation; KNAUER driver part number A1513-07

15) 4 channels, up to 50 Hz data rate 16) 8 channels, up to 10 Hz; PurityChrom® offers only limited 3D functionality, refer to the PurityChrom® manual

17) up to 2 Hz, not in a system with CM 2.1S

18) not in a system with RID 2.1L

Assistant (up to three devices in one housing)

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

ASM 2.1L 1), 2) OLEE A.01.05 / A.04.05 Driver 1017 3)

CC 3.0.7; Driver 3078 4) 5)

n/a CG 3.3.2; Driver 2825 Version: 5.07.039 6)

1) configuration depends on order; please refer the allowed configuration and restrictions in our FAQ

2) only one LAN port for all devices

3) only one valve as fraction collector, no cascading if controlled as ASM; devices can also be controlled as separate

devices via IP port; if a valve configured as KNAUER MultiValve FC valve can be controlled as separate device via IP port, only then cascading is possible

4) ASM is only supported as complete Assistant; included modules cannot be controlled as separate devices (IP port separation is not supported)

5) only one valve as fraction collector, no cascading

6) ASM is not supported as device; the included modules can be controlled as separate devices via IP port;

only one valve as fraction collector

Autosamplers (one autosampler in a system)

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

AZURA® Autosampler AS 6.1L

OLEE A.01.05 / A.04.05 Driver 2109

CC 7.2.0.5043 Cm 7.2 Regular Class 3 driver

n/a Version: 5.08.024

Smartline Autosampler 3950 1)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.4.4 / LAN from CC 2.6.5 Driver 1083 6)

Cm 7.2 Regular Class 3 driver; Cm 6.8 SR10 Regular Class 3 driver 6)

CG 3.1.7 Driver 1466 / LAN from CG 3.3.1 Driver 1640

Version: 5.07.067 6)

PLATINblue Autosampler AS-1

OLEE A.01.05 / A.04.05 Driver 1017

CC 6.1.0, Driver 5015

Cm 6.8 SR10 Regular Class 3 driver

CG 3.3.2 PLATINblue Edition 1751; Regular 2825

n/a

Autosampler KNAUER Optimas

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3055 3)

n/a n/a n/a

Smartline Autosampler 3800 (also WellChrom K-3800, Spark Marathon)

n/a CC 2.4.4 3) Cm 6.8; Generic driver 4)

CG 3.3.2 Driver 1787 Version: 5.07.039

Smartline Autosampler 3900 (also Spark Midas)

n/a CC2.4.4 3) Cm 6.8; Generic driver 4)

CG 2.8 Version: 5.07.039

Spark Triathlon n/a CC 2.4.4 3) Cm 6.8; Generic driver 4)

CG 2.55 Version: 5.07.039

Supported devices

Page 72: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�66

Autosamplers (one autosampler in a system)

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

Kontron Autosampler 360

n/a CC 5.0.2 3) - CG 3.1.7 Driver 1466 5)

n/a

Kontron Autosampler 46x

n/a - - CG 3.1.7 Driver 1466 5)

n/a

Kontron Autosampler 56x

n/a CC 5.0.2 3) - CG 3.1.7 Driver 1466 5)

n/a

1) some device features have been added from time to time; therefore, not all of the current features are supported in the software from beginning (as LAN connection, TCP/IP support, 84+3 vial tray, 108 vial tray, thermostating up to 40 0C, 0.1 µl increments for injection volume and smallest injection volume); the features require a device with the appropriate firmware and hardware version

2) LAN default configuration is LAN via DHCP, static IP address requires access to built-in LAN module 3) driver was developed by Data Apex 4) upon request - driver was not developed by KNAUER

5) special RS-232 cable is required

6) no Stacked Injection supported

Analog/Digital Converters

OpenLAB® CDS EZChrom Edition CDS version and Driver Version 1)

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

KNAUER Interface Box IFU 2.1 LAN 2)

OLEE A.01.05 / A.04.05 Driver 2092

CC 6.0.1 Driver 5043 (compatible with CC/CCP 5.x versions)

n/a n/a Version: 5.08.024

KNAUER Interface Box IFU 2.1 3), 4), 5)

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3078, in former version as IF2 5)

n/a CG 3.3.2 Driver 2825, in former version as IF2 5)

Version: 5.07.039 6)

KNAUER Interface Box IF2 4)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.4.4 / 2.6 7), 8) n/a CG 3.1 9) Version: 5.07.039

Smartline Manager 5000 4)

n/a CC 2.4.4/2.6 7), 8) n/a CG 3.1 9) n/a

Smartline Manager 5050 4)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.6.5 Driver 1100 5)

n/a CG 3.3.2 Driver 1751 5)

n/a

KNAUER HPLC Box Model 96 10)

n/a CC 2.6 11) n/a CG 2.55 12), 13) n/a

Kontron Interface Card 14)

n/a - - CG 3.1.7 Driver 1466 n/a

1) A/D converter in OpenLAB® must be configured separately; menu is available via Start – Programs – Agilent Technologies – OpenLAB® CDS EZChrom Edition, right click on Agilent SS420X Interface Configuration and select Run as Administrator

2) to set a static IP address a 3rd party tool is required

3) built-in USB-to-serial converter requires separate installation of a driver in Windows operating system, can be found on the HPLC software CD or KNAUER webpage (Download section for IFU 2.1, Article Number AZB00); check Windows Device Manager for the COM port number of the converter, this number must be selected in the software configuration

4) as the required serial number in the configuration, enter the last 5 digits of the serial number on the label; if the first digit is a 0 (zero), only enter the last four digits

5) in previous software versions IFU 2.1 can be controlled as IF2 or Manager 5000 if IFU 2.1 is not listed in the module list 6) analog input only

7) in ClarityChrom® version 2.4.4 only data acquisition via analog input is supported (max. 10 Hz), analog out supported from ClarityChrom® version 2.6

8) 50 Hz option for channel 1 supported from version ClarityChrom® version 2.6 9) 50 Hz option for channel 1 supported from version ChromGate® version 3.1.4

10) as the required serial number in the configuration, enter the last 5 digits of the serial number on the label, if the serial number is higher than 40000, please enter only the last four digits

Supported devices

Page 73: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�67

11) supported as “Basic Edition”, ClarityChrom® will switch the box into the required mode 12) supported as “Integration Box” only for data acquisition via analog input; box must be switched into the correct mode with special software

13) 100 Hz option for channel 1 supported from version ChromGate® version 3.1

14) requires an ISA slot on the computer

Thermostats/Column ovens

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

Column Thermostat CT 2.1

OLEE A.01.05 / A.04.05 Driver 1027

CC 5.0.3 driver 4102 Cm 7.2 Regular Class 3 driver

n/a n/a

PLATINblue Column Thermostat T-1

OLEE A.01.05 / A.04.05 Driver 1017

CC 5.0.2 Driver 4095

Cm 6.8 SR10 Regular Class 3 driver

CG 3.3.2 PLATINblue Edition 1751; Regular 2825

n/a

Smartline Column Oven / Column Thermostat JetStream / PLATINblue T-1 Basic 1), 2)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.4.4 Cm 6.8 SR10 Regular Class 3 driver

CG 3.1 Coming soon

Smartline Column Oven 4050 3)

n/a CC 2.4.4 n/a CG 3.1.7 Driver 1466 n/a

1) firmware version b1.17 or higher required

2) if connected, control panel must show “Choose Function” before the instrument will be opened

3) device does not support static IP address, only LAN via DHCP from firmware version 1.11

Electrical valve drives

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

AZURA® Valve V 2.1S 1)

OLEE A.01.05 / A.04.05 Driver 1017

CC 3.0.7 Driver 3078 1)

n/a 2), 3) n/a 1) Version: 5.07.039

WellChrom electric valve drives K-6, K-12, K-16

n/a 4) CC 2.4.4 CM 6.8 Generic driver 3)

CG 2.8 Version: 5.07.039

Smartline valve drives S6, S12, S16 1)

OLEE A.01.05 / A.04.05 Driver 1017

CC 2.4.4 CM 6.8 Generic driver 3)

CG 3.1 1) Version: 5.07.039

VICI Valco drives OLEE A.01.05 / A.04.05 Driver 1017

CC 5.0.2 5) Implemented (not by KNAUER)

Generic Driver 3) -

1) can be controlled as KNAUER switching valve if not listed in the module list of previous software versions (maybe limited on RS-232) 2) generic driver for KNAUER switching valves will also work with AZURA® V 2.1S (RS-232 only)

3) generic drivers do not support all of the devices features (e.g. RS-232 only) 4) can be controlled as KNAUER switching valve

5) driver was developed by Data Apex

Other supported instruments

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

Airsensor 1) n/a n/a n/a n/a Version: 5.07.039Pressure control (pressure difference) 2)

n/a n/a n/a n/a Version: 5.07.039

Supported devices

Page 74: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�68

1) communication via game port adapter 2) requires KNAUER IFU 2.1/ IFU 2.1 LAN

Fraction collectors (one fraction collector in a system, no combination of a fraction valve and a fraction collector possible)

OpenLAB® CDS EZChrom Edition CDS version and Driver Version

ClarityChrom® CDS version and Driver Version

Chromeleon™ CDS version Driver version

ChromGate® CDS version and Driver Version

PurityChrom®

KNAUER MultiValve Fraction Collector (all KNAUER electric valve drives; 2, 6, 12 and 16 ports)

OLEE A.01.05 / A.04.05 Driver 1017 1)

CCP 2.6 2) n/a CG 3.1.6 Driver 423 1)

Version: 5.07.039 3)

ASM 2.1L valve OLEE A.01.05 / A.04.05 Driver 1017, 13)

CC 3.0.7; Driver 3078, 14)

n/a CG 3.3.2; Driver 2825 15)

Version: 5.07.039 16)

Smartline Fraction Collector 3050 4)

n/a CCP 2.6 n/a CG 3.3.1 Driver 1640 n/a

Büchi Fraction Collector C-684 5)

n/a n/a n/a CG 3.1.6 Driver 423 n/a

Büchi Fraction Collector C-660

OLEE A.01.05 / A.04.05 Driver 1017

CCP 2.6 n/a CG 3.1.6 Driver 423 n/a

ISCO Fraction Collector Foxy Jr.

n/a CCP 2.6 Implemented (not by KNAUER)

CG 3.1.6 Driver 423 Version: 5.07.039

ISCO Fraction Collector Foxy R1 6)

OLEE A.01.05 / A.04.05 Driver 1017 7)

CCP 2.6.5 Driver 1094 (RS-232 only) 8)

Implemented (not by KNAUER)

CG3.3.2 Driver 1751 7)

Version: 5.07.039

ISCO Fraction Collector Foxy R2 6)

OLEE A.01.05 / A.04.05 Driver 1017 7)

CCP 2.6.5 Driver 1094 (RS-232 only) 8)

n/a CG3.3.2 Driver 1751 7)

Version: 5.07.039

ISCO Fraction Collector Foxy 200 9)

n/a CCP 2.6 – CCP 2.6.5 Driver 1100, 9)

Implemented (not by KNAUER)

CG 3.1.7 Driver 1466 – CG3.3.2 Driver 1751, 9)

n/a

Labocol Vario 2000 Fraction Collector

OLEE A.01.05 / A.04.05 Driver 1017

n/a n/a CG 3.1.6 Driver 423 n/a

Labocol Vario 4000 Fraction Collector

OLEE A.01.05 / A.04.05 Driver 1017

n/a n/a CG 3.3.1 Driver 1640 n/a

VICI Valco MultiValve Fraction Collector

OLEE A.01.05 / A.04.05 Driver 1017 1)

n/a from KNAUER, valve is supported in ASM 2.1L as FC 10) 11)

n/a CG 3.3.1 Driver 1640 1)

Version: 5.07.039 3)

Virtual Fraction Collector

OLEE A.01.05 / A.04.05 Driver 1017

CCP 2.6 n/a CG 3.1.6 Driver 423 n/a

Injection Module (combined module with pump and injection valve for injection of large injection volumes, allows for stacked injection) 12)

OLEE A.01.05 / A.04.05 Driver 1017

n/a n/a CG 3.3.1 Driver 1640 n/a

1) up to 32 valves in a cascade 2) up to 12 valves in a cascade

3) only one valve can be used as fraction collector, no cascading is supported 4) switch between RS-232 and LAN with a switch on the devices rear panel

5) requires special relay module for serial communication 6) touch panel is not blocked in remote, do not touch it while the device is under software control

7) LAN control from firmware version 1.01.03, LAN control support in firmware versions 1.01.09 and 1.01.11 faulty

Supported devices

Page 75: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�69

8) only RS-232, communication via LAN is not supported 9) support is discontinued due to several incompatible firmware versions; not all devices may work with the driver

10) not all available valve types can be built-in into ASM 2.1L 11) driver from DataApex available; does not support KNAUER fractionation features

12) several pumps were added to the module when released; however, a pump is only supported in the injection module if the mentioned pump is also available as a separate pump; in ASM2.1L pump and valve must be controlled separately, refer

software manual for detailed information 13) only one valve as fraction collector, no cascading if controlled as ASM; if configured as KNAUER MultiValve FC valve can be controlled as separate device via IP port, only then cascading is possible

14) only one valve as fraction collector in ASM, no cascading

15) only one valve as fraction collector, no cascading if controlled as ASM; if configured as KNAUER MultiValve FC valve can be

controlled as separate device via IP port, only then cascading is possible 16) only one valve as fraction collector, no cascading

Mobile Control

Mobile Control (KNAUER): Version 4.0.0 also with data acquisition support, supports AZURA® devices:

- Pump P 2.1S/P 4.1S – Firmware V01.37

- Pump P 6.1L – Firmware V01.03

- Pump P 2.1L – Firmware V01.08

- Detector UVD2.1S – Firmware V01.10

- Detector UVD 2.1L – Firmware V02.05

- Detector MWD 2.1L – Firmware V01.02

- Detector DAD 2.1L – Firmware V01.02

- Detector DAD 6.1L – Firmware V01.23

- Detector RID 2.1L – Firmware V01.10

- Valve V 2.1S – Firmware V4.14

- Assistant ASM 2.1L – Firmware V01.12

- Column thermostat CT 2.1 – Firmware V01.06

- Autosampler AS 3950 – Firmware V01.16

Mobile Control version 4.0.0 requires OpenLAB® EE from driver version 2092 and ClarityChrom®/Prep 5.0.5/6.1.0 from driver version 5037.

Mobile Control (KNAUER): Version 3.0.1 also with data acquisition support, supports AZURA® devices:

- Pump 6.1L (from firmware version 1.03)

- Pump 2.1L (from firmware version 1.08)

- Pump P 2.1S/P 4.1S (from firmware version 1.32)

- UVD 2.1L (from firmware version 2.04)

- DAD 2.1L (from firmware version 1.1)

- DAD 6.1L (from firmware version 1.21)

- MWD 2.1L (from firmware version 1.1)

- UVD 2.1S (from firmware version 1.08)

- ASM 2.1L (from firmware version 1.11)

- Valve V 2.1S (from firmware version 4.14)

- CT 2.1 (from firmware version 1.06)

Supported devices

Page 76: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�70

Mobile Control (KNAUER): Version 2.2.0 supports AZURA® devices:

- Pump 6.1L (from firmware version 1.02)

- Pump 2.1L (from firmware version 1.07)

- Pump P 2.1S/P 4.1S (from firmware version 1.32)

- UVD 2.1L (from firmware version 2.04)

- DAD 2.1L (from firmware version 1.1)

- DAD 6.1L (from firmware version 1.21)

- MWD 2.1L (from firmware version 1.1)

- UVD 2.1S (from firmware version 1.08)

- ASM 2.1L (from firmware version 1.10)

- Valve V 2.1S (from firmware version 4.14)

- CT 2.1 (from firmware version 1.06)

Monitor Mode supported in OpenLAB® EE from driver version 2047 and ClarityChrom/Prep 5.0.5/6.1.0 from driver version 5015.

Other software

LabView (National Instruments): Driver for AZURA® Pumps P 2.1S / P 4.1S, Smartline 100, BlueShadow Pumps 10P / 20P

HyStar TM

(Bruker): Compass HyStar TM

3.2 Plug-in: Drivers for PLATINblue system (Pump P-1, DAD PDA-1, UV Detector MW-1, Column Thermostat T-1, Autosampler AS-1, Manager M-1 (LPG valves only, interface module is not supported)

Compass HyStar TM

4 Plug-in: Driver for AZURA® DAD 6.1L

Xcalibur TM

(Thermo): Version 2.0.7 and 2.1: Driver for PLATINblue Pump P-1, UV Detector MW-1, DAD PDA-1, Autosampler AS-1, Column Thermostats T-1 and T-1 Basic and Smartline Pump S 1050, UV Detector S 2550, Autosampler S 3950 and Column Thermostat JetStream

Supported devices

Page 77: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�71

Conversion tables

inches  mm1/32" 0,81/16" 1,6

1/8" 3,21/4" 6,43/8" 9,51/2" 12,7

1" 25,4

mm inches0,10 .004"0,12 .005"0,15 .006"0,25 .010"0,40 .016"0,50 .020"0,75 .030"1,00 .040"1,50 060"2,00 .080"4,60 .180"6,00 .236"6,40 .253"7,00 .276"

10,00 .400"

Tubing ID µl/cm µl/in.004" 0,08 0,21.005" 0.13 0.32.010" 0.51 1.29.015" 1.14 2.90.020" 2.03 5.15.025" 3.17 8.04.030" 4.56 11.58.040" 8.11 20.59.060" 18.24 46.33.070" 24.83 63.06.085" 36.61 92.99

Tubing volume/Length conversion chart

MPa bar psi5 50 725

10 100 1.45020 200 2.90130 300 4.35140 400 5.80250 500 7.25260 600 8.70270 700 10.15380 800 11.60390 900 13.054

100 1.000 14.504110 1.100 15.954120 1.200 17.405130 1.300 18.855140 1.400 20.306150 1.500 21.756160 1.600 23.206170 1.700 24.657180 1.800 26.107190 1.900 27.558200 2.000 29.008

Pressure conversion chart

°C °F °C °F °C °F-40 -40 65 149 170 338-35 -31 70 158 175 347-30 -22 75 167 180 356-25 -13 80 176 185 365-20 -4 85 185 190 374-15 5 90 194 195 383-10 14 95 203 200 392

-5 23 100 212 205 4010 32 105 221 210 4105 41 110 230 215 419

10 15 115 239 220 42815 59 120 248 225 43720 68 125 257 230 44625 77 130 266 235 45530 86 135 275 240 46435 95 140 284 245 47340 104 145 293 250 48245 113 150 302 255 49150 122 155 311 260 50055 131 160 320 265 50960 140 165 329 270 518

Temperature conversion chart

Dimensions

Page 78: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�72

Notes

Page 79: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

�73

Order request

Company:

Name:

Date:

Part No.: Description Qty. Price

Page 80: AZURA® instruments &amp; components for (U)HPLC, Prep LC, · PDF fileDiode array detectors ... Electrochemical detector ... Vials and caps kits for analytical HPLC 57 Vials and caps

KNAUER Wissenschaftliche Geräte GmbHHegauer Weg 3814163 Berlin, Germany

+49 30 809727-0+49 30 8015010 (Fax)[email protected]

Distributed by:

© K

NA

UER

201

8 V

7854

-2U

S/2.

0/05

.17/

KN

Ver

sio

n 1.

1

Technical data or prices are subject to change without

notice. Prices may vary by country and do not include

taxes, customs duties or delivery.

All trademarks are the property of their respective

owners. Our general terms and conditions apply:

www.knauer.net/terms

We separate moleculesand unite people.As experts in liquid chromatography, we continue the path of our founder Dr. Knauer: Together with scientists in the lab we develop innovative and individual solutions. We are curious and creative. This makes us the ideal partner for those wanting more than a standard solution.

KNAUER is an established partner in science. We support research and technological advancement today and in the future.

Please check out the KNAUER website for

further detailed information: www.knauer.net

Information on chemical compatibilities are stated

in the user manuals: www.knauer.net/knowledge