CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLE NUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE 40AST 00041 3/8 1/2 50 500 1.410 .850 .405 1.000 .485-.612 400AST 40347 3/8 1/2 50 500 1.280 .850 .400 1.000 .485-.612 Refer to chart on page E-26 for a list of cable types. Concrete tight when taped. Flexible metal conduit, CSA listed with anti-short bushing (UL not applicable). SNAP-TITE ® and SNAP 2 IT ® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6. PATENTED. ADDITIONAL PATENTS PENDING. CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLE NUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE 38AST* 00070 3/8 1/2 50 500 1.410 .850 .405 1.000 .405-.612 38A* 00038 3/8 1/2 50 500 1.410 .850 .405 1.000 .405-.612 380ST 00381 3/8 1/2 50 500 1.280 .850 .400 1.000 .405-.612 380AST* 00382 3/8 1/2 50 500 1.280 .850 .400 1.000 .405-.612 *Provided with insulated throat. E-1 Flex • AC • MC 380AST E18304 LR49636 E18304 LR49636 SNAP 2 IT Connectors are EASY to Install... And EASY to Remove... RED TINTING means ‘OPEN TANG’ Design! It gives you more room inside the fitting for easy insertion of wires. The redesigned front end makes it easier than ever to snap the fitting into box! COMPARE... SNAP 2 IT ® Connectors Zinc die-cast. For MC/HCF steel and aluminum cable • AC/HCF steel and aluminum cable • Flexible metal conduit steel and aluminum (regular and reduced wall) • MC cable continuous corrugated aluminum. FOR EASIER MC/AC INSTALLATIONS... 38AST 38A D C B A 38AST Using a screwdriver, lift the ring and twist off. With Insulated Throat and Red Tinted Inside Clip 38AST 40AST Just snap onto cable and snap into box! NO TOOLS! • Safe and fast installations • Saves about 17 seconds per fitting! • Competitively priced 38AST 40AST See 3810AST to 7510AST on Page E-2 Arlington Industries, Inc. www.aifittings.com • E-mail: [email protected]800/233-4717 • FAX 570/562-0646 This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
27
Embed
Arlington Industries, Inc. - Barr-Thorp · Arlington Industries, Inc. • E-mail: [email protected] 800/233-4717 • FAX 570/562-0646 CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
40AST 00041 3/8 1/2 50 500 1.410 .850 .405 1.000 .485-.612400AST 40347 3/8 1/2 50 500 1.280 .850 .400 1.000 .485-.612Refer to chart on page E-26 for a list of cable types.Concrete tight when taped.Flexible metal conduit, CSA listed with anti-short bushing (UL not applicable).SNAP-TITE® and SNAP2IT® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED. ADDITIONAL PATENTS PENDING.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
SNAP2IT Connectors are EASY to Install... And EASY to Remove...
RED TINTING means‘OPEN TANG’ Design! It gives you more room inside the fitting for easy insertion of wires. The redesigned front end makes it easier than ever to snap the fitting into box!
COMPARE...
SNAP2IT®
ConnectorsZinc die-cast. For MC/HCF steel
and aluminum cable • AC/HCF
steel and aluminum cable •
Flexible metal conduit steel and
aluminum (regular and reduced
wall) • MC cable continuous
corrugated aluminum.
FOR
EASIER MC
/AC
INSTALLATI
ONS...
38AST38A
DC
B
A38AST
Using ascrewdriver,lift the ringand twistoff.
With Insulated Throat and Red Tinted Inside Clip
38AST
40ASTJust snaponto cableand snapinto box!
NO TOOLS!• Safe and fast installations• Saves about 17 secondsper fitting!• Competitively priced 38AST 40AST
†Provided with red tinted inside clip so you can differentiate a3810AST from a 4010AST.Refer to chart on page E-26 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges.Concrete tight when taped.SNAP-TITE® and SNAP2IT® products have been testedand listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENT PENDING.
E18304 LR49636
A
C
D
B
Easy cable insertion – Tight, secure hold!
SNAP2IT®
Connectors withInsulated ThroatZinc die-cast. For MC/HCF steel
and aluminum cable • AC/HCF
steel and aluminum cable •
Flexible metal conduit steel and
aluminum (regular and reduced
wall) • MC cable continuous
corrugated aluminum • MCI-A
steel and aluminum cable.
New!
3810AST
4010AST
Features and Benefits• Installs as fast and costs the same as our other SNAP2IT fittings, but cable insertion is even easier!• Simply snap the cable into the fitting and snap it into the box... no tools needed! The screw only holds the clip in place.• Widest cable ranges – accommodates cable from 14/2 to 10/4.• Super-secure – the angled, two-prong clip locks down on MC cable so there’s no chanceof pullout.• Cable is removable. Simply loosen the screw on top.
Back ViewNote angled,two-prongclip
Top ViewClip holdscable firmlyin place
FOR THE
WIDEST TO
TAL
CABLE RAN
GES
�
�
5010AST
7510AST
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
*Provided with insulated throat.†Provided with insulated throat and red tinted inside clips. See comparison on page E-1.Refer to chart on page E-26 for a list of cable types.Concrete tight when taped.SNAP-TITE® and SNAP2IT® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED. ADDITIONAL PATENTS PENDING.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
†Provided with red tinted inside clips so you candifferentiate a 383810AST from a 404010AST.Refer to chart on page E-26 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges.Concrete tight when taped.SNAP-TITE® and SNAP2IT® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENT PENDING.
E18304 LR49636
A
C
D
B
SNAP2IT® DuplexConnectors withInsulated ThroatZinc die-cast. For MC/HCF steel
and aluminum cable • AC/HCF
steel and aluminum cable •
Flexible metal conduit steel and
aluminum (regular and reduced
wall) • MC cable continuous
corrugated aluminum • MCI-A
cable.
New!
Secure hold – Easy cable insertion!
FOR THE
WIDEST TO
TAL
CABLE RAN
GES
Simply snap the cable into the fitting andsnap it into the box...no tools needed! The screw only holds the clip in place.
FOR EASIER
MC/AC
INSTALLATI
ONS...
See38381
0AST & 40
4010AST
(Above)
NewDES
IGN!
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
3890AST 03890 3/8 1/2 25 250 3.081 1.222 2.480 1.688 .405-.6124090AST† 04090 3/8 1/2 25 250 3.081 1.222 2.480 1.688 .485-.6125090AST† 05090 1/2 1/2 25 250 3.460 1.222 2.455 1.878 .860-.920†Provided with red tinted inside clip. See comparison on page E-1.Refer to chart on page E-26 for a list of cable types.Concrete tight when taped.SNAP-TITE® and SNAP2IT® products have been testedand listed by UL in accordance with UL’s ground faultrequirements. For additional information see page 6.PATENTED. ADDITIONAL PATENTS PENDING.
Zero to 90™
SNAP2IT®
Connectors withInsulated ThroatZinc die-cast. For MC/HCF steel
and aluminum cable • AC/HCF
steel and aluminum cable •
Flexible metal conduit steel and
aluminum (regular and reduced
wall) • MC cable continuous
corrugated aluminum.
E18304 LR49636
AC
D
B
TM
Adjusts for ALL ANGLES... from 0° to 90°!
Installation Instructions...
Snap cable into fittinguntil it stops. Rotate cableclockwise to lock in place.
Loosen nut to adjust angle of fitting. Wires bendautomatically — withoutcrimping or damage to wire.
Tighten nut. Snapassembly into the KO.
1 2 3
Saves over a minute oninstallation per connectorwhen compared with atraditional locknut fitting!
�
�
“Take All”ConnectorsSingle screw saddle type.
For NM • Flex • AC • MC
steel and aluminum jacketed
cables. Zinc die-cast.
L15A
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLE END STOPNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE DIAMETER
*Provided with insulated throat.†Listed for flexible cord.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-25 for a list of cable types.Concrete tight when taped.PATENTED. ADDITIONAL PATENTS PENDING
E60812 LR49636
L15A L17 - L19L160 L16
L16
A
B
C
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
*Provided with insulated throat.†Listed for flexible cord.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-25 for a list of cable types.Concrete tight when taped.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED. ADDITIONAL PATENTS PENDING.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE
845ST 80092 3/8 1/2 100 1000 .942 .510 .905 .445-.630Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.Not suitable for aluminum jacketed cables or aluminum flexible metal conduit.SNAP-TITE® products have been tested and listed by UL in accordance withUL’s ground faultrequirements. For additional information see page 6.PATENTED.
E60812 LR49636
Set-Screw SNAP-TITE®
ConnectorsWith spring steel clip. For steel
only • Flex • AC • MC cable.
Zinc die-cast.
B
C
A
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE
845 00845 3/8 1/2 100 1000 .812 .905 .380 .445-.630845R 08459 3/8 1/2 100 1000 .812 .905 .380 .445-.630Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.Not suitable for aluminum jacketed cables oraluminum flexible metal conduit.
Set-ScrewConnectorsFor steel only • Flex • AC • MC
cable. Zinc die-cast.
E60812 LR49636
845 845R
B
A
C�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 PKG PKG A B C D CAPACITY
SMC4 42305 25 25 5.120 1.670 2.380 1.750 4
SMC8 42307 25 25 7.500 1.670 2.380 1.750 8
SMC4F 42315 25 25 7.500 .750 1.640 1.060 4
PATENT PENDING.
E161207 LR49636
Need photo of
SMC4F in use
Features and Benefits• Saves money...use SMC steel hangers in place of cable tray• Each cable is held in place independently, so there’s no bundling of cables or derating of conduit• Accepts a wide range of cables... .375 - .625• Mounts on concrete block walls or ceilings and screw mounts onmetal or wood studs• SMC4F also mounts on drop wire• Attach with beam clamp, threaded rod, or with screws• Meets NEC 2008 paragraphs 300.4(E), 320.30 , 320.30(A), 330.30, 330.30(C), and 300.4(E), 348.30(A,B). • Listed to position, support, and secure 14/2 to 10/4 cables – as required by NEC 2008 330-30.
InstallationInstructions...
Bend tab over cable,locking it securely in place.
1 2
Mounts in Many Ways!
SMC8 supports andFIRMLY SECURES up toeight cables to complywith NEC 2008.
SMC4F
Available in three styles tosecure 14/2-10/4 cables:SMC8 holds up to 8 cablesSMC4 holds up to 4 cablesSMC4F mounts flat — holds up to 4 cables on one side
A
C
D
B
SMC8
A
C
D
B
SMC4
A
C
D
B
�
�
CableDecking
For a video installationdemonstration visit our website @aifittings.com
Insert screwdriverthrough slot.
Code Compliant Arlington’s steel MC cablehangers meet the NEWREQUIREMENTS of NEC300.4(e)Installing MC or AC metaljacketed cables undercorrugated metal roof decking.The outer surface of cable mustbe 1-1/2” from the underside ofthe decking. Our SMC hangersexceed this.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
*Listed for MC only. UL# E123751.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-24 for a list of cable types.Refer to E-9 for new MC cable connectors with our largest cable ranges.Concrete tight when taped.
E123751 LR49636
840 8400 8401 8402-8410
A
B
C
840
8400
8401
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLE END STOPNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE DIAMETER
840ST 80070 3/8 1/2 100 1000 .510 .985 .912 .225-.612 .400 x .5808400ST 80074 3/8 1/2 100 1000 .510 .985 .912 .225-.612 .375Refer to chart on page E-24 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges.Concrete tight when taped.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED.
SNAP-TITE®
ConnectorsWith spring steel clip.
Zinc die-cast. For NM • SE •
MC • Flex • AC steel and
aluminum jacketed cables •
MCI-A cable.
840ST
8400ST
E18304 LR49636
A
C
B
840ST 8400ST
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT/STD DIM DIM DIMNUMBER MFG #01 8997 SIZE SIZE PKG A B C
8412 08412 1 1 20 1.756 .541 2.1448413 08413 1-1/4 1-1/4 20 2.156 .683 2.5688414 08414 1-1/2 1-1/2 10 2.466 .790 3.0868415 00583 2 2 10 2.899 .792 3.6968416 08416 2-1/2 2-1/2 5 3.218 .906 4.2508417 08417 3 3 5 3.281 .972 5.000Refer to chart on page E-25 for a list of cable types.Concrete tight when taped.PATENTS PENDING.
A
B
C
Features and Benefits• Low cost – saves time and money!• Fast and Easy to install. There’s no need to remove the strap...just loosen the screws and insert the bushing that works best with the cables you’re installing.• Our zinc die-cast fittings cost much less than steel or malleable iron fittings• Reduces inventory – comes with additional end stop bushings!• Built-in end stop in fitting
31 2No need to remove strap – simplyloosen the screws and insert end stopbushing, if necessary. Slip connectoronto MC cable. Retighten screws onstrap.
If you are using an end stop bushing,determine which one to use by sizingit to the cable bundle (not the metaljacket). Incorrect size shown above.The metal jacket should never gothrough the end stop.
Insert the appropriate end stopbushing, making sure that the half-moon shape is positioned at the top of the connector.
New!
Installation Instructions
Each fitting has an endstop, but comes with
additional end stopbushings toaccommodateseveralcablesizes!
Catalog Cable Wire Bundle Conductor SizeNumber # of Conductors*
Min. Max. Min. Max. Fitting A B C (AWG/KCMIL)8412 .780 1.120 .660 1.000 1.018 .625 .750 .870 6/3, 6/4, 4-3, 4-4,
For a video installation demonstration visit our website @ aifittings.com
* Examples of 3- and 4-conductor cables. Cable dimensions vary dramatically between manufacturers. It is recommended that cable O.D. (outer diameter) be measured to ensure proper cable-to-fitting installation.
A
B
C
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
*L420 not listed for flexible metal conduit.Refer to chart on page E-23 for a list of cable types.Refer to E-9 for new MC cable connectors withour largest cable ranges.Concrete tight when taped.
L42
L421
L427
Sizes 3/8" - 2" aremanufactured as shownabove.
L420 L42
E60812 LR49636
Sizes 2-1/2" - 4" aremanufactured as shownabove.
A
C
B
B
C
A
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
846ST‡ 80050 3/8 1/2 25 250 1.635 .510 .888 1.654 .150-.612846AST* 80052 3/8 1/2 25 250 1.728 .603 .888 1.654 .150-.612*Provided with insulated throat.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
846SS 80054 3/8 1/2 25 250 1.562 .437 .888 2.200 .210-.612Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.
E60812 LR49636
C
A
B
D
Duplex ConnectorZinc die-cast. Single screw for
Flex • AC • MC • NM cable •
MCI-A cable.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
846 00846 3/8 1/2 25 250 1.542 .437 .888 1.672 .150-.612Refer to chart on page E-24 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges. Concrete tight when taped.
E60812 LR49636
Duplex SNAP-TITE®
ConnectorsSingle screw for Flex • AC •
MC • NM cable. Zinc die-cast.
E60812 LR49636
A
C
B
Duplex ConnectorTwin screw with steel strap.
Zinc die-cast. For Flex • NM •
AC • MC steel and aluminum
jacketed cables.
�
�
�
�
�
�
D
B
C
AD
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
84690ST 58230 3/8 1/2 10 100 1.087 1.707 1.965 .458 .512-.612Refer to chart on page E-24 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges.Concrete tight when taped.SNAP-TITE® products have been testedand listed by UL in accordance withUL’s ground fault requirements. For additional information see page 6.PATENTED.
E20643 LR49636
90° DuplexConnectorZinc die-cast. Twin screw for
Flex • NM • AC • MC steel and
aluminum jacketed cables •
MCI-A cable.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C D RANGE
84690 00090 3/8 1/2 10 100 1.087 1.707 1.965 .379 .512-.612Refer to chart on page E-24 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges.Concrete tight when taped.
E60812 LR49636
A
B
D
C
A
B
D
C
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLE END STOPNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE DIAMETER
L48 34800 1/2 1/2 25 250 1.470 .450 1.260 .625-.915 .620L49 34900 3/4 3/4 20 200 1.540 .450 1.500 .820-.910 .815Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.
Set-ScrewConnectorsFor Flex • AC • MC cable.
Zinc die-cast. Not for use with
aluminum jacketed cables.
E60812 LR49636
AB
C
�
�
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE
SG3838 17383 3/8 1/2 25 100 .452 1.526 .780 (2) .445-.612SG3838A* 36205 3/8 1/2 25 100 .512 1.586 .780 (2) .445-.612*Provided with insulated throat.Refer to chart on page E-24 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges.Concrete tight when taped.With independent securing of the cables,you can use two different size cables.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLE END STOPNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE DIAMETER
*Provided with insulated throat.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-25 for alist of cable types.Concrete tight when taped.For cables smaller than .405" see L16 and L16ST on page E-5.
SADDLEGRIP®
ConnectorsFor aluminum and steel Flex •
AC • MC cable. Zinc die-cast.
SG380 SG38
E60812 LR49636
DuplexSADDLEGRIP®
ConnectorsZinc die-cast. For aluminum
and steel Flex • AC • MC
cable • MCI-A cable.
E60812 LR49636
C
B
A
A
B
C
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
*Provided with insulated throat.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-25 for a list of cable types.Concrete tight when taped.For cables smaller than .405" see L16 and L16ST on page E-5.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additional information see page 6.PATENTED.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE
SG3838ST 80152 3/8 1/2 25 100 .455 1.560 .780 (2) .445-.612SG3838AST* 36210 3/8 1/2 25 100 .605 1.610 .780 (2) .445-.612*Provided with insulated throat.Refer to chart on page E-24 for a list of cable types.Refer to chart on page E-27 for MCI-A cable ranges.Concrete tight when taped.With independent securing of the cables, you can use two different size cables.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground faultrequirements. For additional information see page 6.PATENTED.
SADDLEGRIP®
SNAP-TITE®
ConnectorsFor aluminum and steel Flex •
AC • MC cable. Zinc die-cast.
MCI-A cable.
SG38AST
SG380AST
E60812 LR49636
SG380AST SG38AST
E60812 LR49636
DuplexSADDLEGRIP®
SNAP-TITE®
ConnectorsZinc die-cast. For aluminum
and steel Flex • AC • MC
cable • MCI-A cable.
A
B
C
A
B
C
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLE END STOPNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE DIAMETER
4501ST 06002 3/8 1/2 50 500 .382 1.132 1.588 .445-.612 .6204502ST 06004 1/2 1/2 25 250 .382 1.150 1.775 .620-.895 .635Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additionalinformation see page 6.PATENTED.
45° SNAP-TITE®
ConnectorsWith spring steel clip.
For aluminum and steel Flex •
AC • MC cable. Zinc die-cast.
E60812 LR49636
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLE END STOPNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE DIAMETER
4501 04501 3/8 1/2 50 500 .382 1.132 1.588 .445-.612 .6204502 04502 1/2 1/2 25 250 .382 1.150 1.775 .620-.895 .635Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.
45° ConnectorsFor aluminum and steel Flex •
AC • MC cable. Zinc die-cast.
E60812 LR49636
C
B
A
A
C
B
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE
850ST 80154 3/8 1/2 50 500 1.540 .430 1.800 .440-.750850AST* 80156 3/8 1/2 50 500 1.600 .490 1.775 .440-.750851ST‡ 80158 1/2 1/2 25 250 1.600 .430 2.140 .642-1.075851AST*‡ 80160 1/2 1/2 25 250 1.651 .490 2.145 .648-1.081*Provided with insulated throat.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-23 for a list of cable types.Concrete tight when taped.SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground fault requirements. For additionalinformation see page 6.PATENTED.
90° SNAP-TITE®
ConnectorsWith spring steel clip.
For aluminum and steel Flex •
AC • MC cable. Zinc die-cast.
MCI-A cable.
E18304 LR49636
CABLE
RANGE
C
A
B
�
�
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE
85‡ 00893 3/8 1/2 50 500 1.370 .340 1.800 .370-.51085A* 12510 3/8 1/2 50 500 1.432 .400 1.800 .370-.510*Provided with insulated throat.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.PATENT PENDING.
90° ConnectorsFor aluminum and steel
Flex • AC • MC cable.
Zinc die-cast. MCI-A cable.
E18304 LR49636
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C RANGE
85ST‡ 00894 3/8 1/2 50 500 1.540 .430 1.800 .370-.51085AST* 12511 3/8 1/2 50 500 1.600 .490 1.800 .370-.510*Provided with insulated throat.‡Also for MCI-A cable. Refer to page E-27 for cable ranges.Refer to chart on page E-24 for a list of cable types.Concrete tight when taped.SNAP-TITE® products have been tested and listed by UL in accordancewith UL’s ground fault requirements. For additional information see page 6.PATENT PENDING.
90° SNAP-TITE®
ConnectorsWith spring steel clip.
For aluminum and steel Flex •
AC • MC cable. Zinc die-cast.
MCI-A cable.
E18304 LR49636CABLE
RANGE
C
A
B
CABLE
RANGE
A
CB
Screw-On Snap-InConnectorsSpring steel clip with non-
metallic body. Screws onto
3/8" Flex.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIMNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B
Screw-InConnectors withInsulated ThroatFor flexible metal conduit.
Zinc die-cast.
C
A
B
Screw-InSNAP-TITE®
ConnectorsWith spring steel clip.
For flexible metal conduit.
Zinc die-cast.
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIMNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C
GF38ST 80162 3/8 1/2 50 500 1.470 .475 1.055GF50ST 80166 1/2 1/2 50 250 1.468 .720 1.055GF75ST 80170 3/4 3/4 25 250 1.694 .940 1.350SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground faultrequirements. For additional information see page 6.PATENTED.
E60812 LR49636C
A
B
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIM DIMNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B C
GF38AST 80164 3/8 1/2 50 500 1.456 .480 1.045GF50AST 80168 1/2 1/2 50 250 1.456 .727 1.045SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground faultrequirements. For additional information see page 6.PATENTED.
Screw-In SNAP-TITE®
Connectors withInsulated ThroatWith spring steel clip.
For flexible metal conduit.
Zinc die-cast.
E60812 LR49636
BC
A
�
�
�
�
�
�
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIMNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B
GF850 85000 1/2 1/2 25 100 1.975 1.820
90° ConnectorsFor flexible metal conduit.
Screw in type with sliding
cover. Zinc die-cast.
E60812 LR49636
CATALOG UPC/DCI/NAED TRADE KO UNIT STD DIM DIMNUMBER MFG #01 8997 SIZE SIZE PKG PKG A B
GF850ST 84850 1/2 1/2 25 100 1.969 1.969SNAP-TITE® products have been tested and listed by UL in accordance with UL’s ground faultrequirements. For additional information see page 6.PATENTED.
90° SNAP-TITE®
ConnectorsWith spring steel clip.
For flexible metal conduit.
Screw-in type with sliding
cover. Zinc die-cast.SLIDING COVER
E60812 LR49636
A
B
A
B
Stackable AC/MC/Flex Cable StrapHolds AC • MC • Flex cable
securely centered on wood or
metal studs...14/2, 14/3,
14/4, 12/2, 12/3, 12/4,
10/2, 10/3.
CATALOG UPC/DCI/NAED UNIT STD DIM DIM DIM CABLENUMBER MFG #01 8997 PKG PKG A B C RANGE
NM310 54010 100 1000 1.345 1.224 .750 .420-.600
PATENTED.
E161207 LR49636
A
B
C
CABLE RANGE
The easy to use ‘Stackable’ Cable Strap holds upto 5 runs of cable!• Meets 2008 NEC Codes 320.30, 330.30, and 348.30• Meets requirements of proposed UL standard 2239 for support of conduit and cable• Includes screw for attaching to wood or metal studs• Listed for use in environmental air handling spaces per 2008 NEC code requirement 300-22(c).
Screw to the stud,then add as many as
you need!
Listed for support, not justpositioning!
�
�
�
�
�
�
SLIDINGCOVER
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com