SERVICE TIPS Dometic AMES/AES/ROYALE/ELlTE REFRIGERATORS Models SILHOUETTE AMES/AES S1521 S1531 S1621 S1631 S1821 S1831 DOMETIC DOMETIC AMES/AES ROYALE RM2607 RM3662 RM2611 RM3663 RM2807 RM3862 RM2811 RM3863 RM3607 RM3807 DOMETIC ELITE RM4872 RM4873 Refrigerator Start-Up Information The new Dometic Refrigerator has been designed to provide more cooling power than ever before - surpassing all agency requirements and customer expectations. When starting this refrigerator for the very first time, the cooling cycle may require up to four hours of running time before the cooling unit is fully operational. OS1662 3/97 1997 The Dometic Corporation
38

AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

May 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

SERVICE TIPS

DometicAMES/AES/ROYALE/ELlTE

REFRIGERATORS

ModelsSILHOUETTEAMES/AESS1521S1531S1621S1631S1821S1831

DOMETIC DOMETICAMES/AES ROYALERM2607 RM3662RM2611 RM3663RM2807 RM3862RM2811 RM3863RM3607RM3807

DOMETICELITERM4872RM4873

Refrigerator Start-Up InformationThe new Dometic Refrigerator has been designed toprovide more cooling power than ever before -surpassing all agency requirements and customerexpectations. When starting this refrigerator for thevery first time, the cooling cycle may require up tofour hours of running time before the cooling unit isfully operational.

OS1662 3/971997 The Dometic Corporation

Page 2: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THES1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807,RM2811, RM3607, RM3807, RM3662, RM3663, RM3862, RM3863, RM4872and RM4873 REFRIGERATORS.

SYMPTOM CAUSE

1. No operation - no panel lights

2. No operation - has panel lights

3. No AC operation - operates on other mode(s)

4. No DC operation - operates on other mode(s)

5. No gas operation - operates on other mode(s)

6. Insufficient cooling on all mode(s).

OperationDC VoltsFuseWiringUpper Circuit BoardLower Circuit Board

OperationDC VoltsThermistorFusesUpper Circuit boardWiringLower Circuit Board

OperationAC VoltsFuseHeating ElementUpper Circuit BoardWiringLower Circuit Board

OperationDC VoltsFuseHeating ElementUpper Circuit BoardWiringLower Circuit Board

OperationLP GasManual Gas ValveIgniterHigh Voltage CableElectrodeSolenoidUpper Circuit BoardWiringLower Circuit Board

VentilationLevelingAmbient TemperatureAir LeaksThermistorCooling UnitThermistor Adjuster

Page 3: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

SYMPTOM CAUSE

7. Insufficient cooling on AC - cools properly on other mode(s)

8. Insufficient cooling on DC - cools properly on other mode(s)

9. Insufficient cooling on gas - cools properly on other mode(s)

10. Freezes

11. Changes preset mode

12. Check light on

13. Interior light on when door is closed

14. Rapid formation of frost

15. Water on frame

AC VoltsHeating ElementLower Circuit Board

DC VoltsHeating ElementWiringLower Circuit Board

LP gasOrificeFlue BaffleFlue TubeFlue Cap (if equipped)BurnerLower Circuit Board

ThermistorThermistor AdjusterLower Circuit BoardUpper Circuit Board

OperationDC VoltsWiringUpper Circuit BoardLower Circuit Board

DC VoltsWiringLP GasManual Gas ValveSolenoidOrificeBurnerLower Circuit BoardThermocouple

WiringDoor SwitchDoor Position

Food StorageInterior Liner to FrameHigh HumidityAir Leaks

Interior Liner to FrameHigh HumidityAir LeaksClimate Control Heater

Page 4: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

ICE MAKER SECTION

SYMPTOM

16. Ice Maker fails to start.

17. Ice Maker won’t make ice.

18. Keeps making ice and won’t shut off.

19. Not making enough ice.

20. Too much water is coming out.

21. Ejector blade frozen into ice cubes.

22. Unit is hooked-up no water comes in.

23. Ice maker is running but won’t make cubes.

24. Ice maker will not make ice.

CAUSE

OperationArm in Up PositionAC VoltageWater ValveIce Maker Cycle

Blades Frozen in IceAC VoltageWater ValveIce Maker Cycle

Shut-off arm

OperationMold ThermostatCube SizeIce Maker Cycle

Water Fill AdjustmentWater Valve

Water Fill AdjustmentWater Valve

WaterWater Valve

WaterShut-Off ArmMold ThermostatHold Switch

Ice EjectorMold HeaterTiming Motor

Page 5: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

AMES REFRIGERATOR OPERATION

2-WAY DISPLAY PANEL

3-WAY DISPLAY PANEL

MODELS INCLUDE: S1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807, RM2811

AUTO MODE

When operating in the AUTO mode, the AUTO mode indicator lamp (D) will illuminate. The controlsystem will automatically select between AC and GAS operation with AC having priority over GAS.Either the AC indicator lamp (B) or the GAS indicator lamp (C) will illuminate depending on the energysource selected by the control system. If the control system is operating with AC energy and it thenbecomes unavailable, the system will automatically switch to GAS. As soon as AC becomes availableagain, the control will switch back to AC regardless of the status of GAS operation.

GAS MODE

When operating in the GAS mode, the AUTO mode indicator lamp (D) will not be illuminated. This modeprovides LP gas operation only. The control system will activate the ignition system and will attempt tolight the burner for a period of approximately 45 seconds. If unsuccessful, the CHECK indicator lamp (E)will illuminate and the GAS mode indicator lamp (C) will turn off.

To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position.The control system will attempt a new 45 second ignition sequence. If the refrigerator has not been usedfor a long time or the LP tanks have just been refilled, air may be trapped in the supply lines. To purgethe air from the lines may require resetting the main power ON/OFF button (1) three or four times. Ifrepeated attempts fail to start the LP gas operation, check to make sure that the LP gassupply tanks are not empty and all manual shutoff valves in the lines are open.

If the control is switched to AC or DC operation while the CHECK indicator lamp is on, it will functionproperly, but the CHECK indicator lamp will not go off until the main power ON/OFF button is pressed tothe OFF then ON position.

Page 6: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

DC MODE (3-Way Models Only)

When operating in the DC mode, the DC mode indicator lamp (A) will be illuminated. All other modelamps will be off. The DC mode overrides all other operating modes. If one of the other operating modesis desired, the DC selector button (2) must be in the UP (OFF) position.

SPECIAL FEATURES OF OPERATION

This control system contains a feature where it will continue to operate the cooling system in the eventof a failure of a major operating component. Two different modes of operation can occur in this category.

If the display module becomes nonfunctional, the control system will revert to full automatic operationselecting the best energy source available with AC, DC (3-way only) and GAS priority. The temperatureof the refrigerator will be maintained at the MID position within normal temperature tolerances. Thepower module will continually attempt to reestablish operation of the display module.

The second Special Feature of operation will execute when a failure of the temperature sensing device orassociated electronic circuitry occurs. If this should occur, the control system will operate on the energysource selected via the control panel. The cooling unit will run continuously on the selected energysource. The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installedand the system is reset.

NOTE: The operational range of these refrigerators is 46o to 35o 3°F.

AES REFRIGERATOR OPERATIONModels Include: RM3607 and RM3607

AES MODE

3-WAY AES DISPLAY PANEL

The AES mode of operation takes priority over all other operating modes. If more than one mode selectorbutton (2), (3) or (4) is in the down position, the priority is from left to right.

When operating in the AES mode, the AES mode indicator lamp (A) will illuminate. In this mode thecontrol system will automatically select the energy source with AC having top priority, DC second priorityand GAS third priority. If the control system has selected a particular energy source such as AC, and thenit becomes unavailable, it will automatically seek out the next available energy source.

AC/GAS MODEWhen operating in the AC/GAS mode the AC/GAS mode indicator lamp (B) will illuminate. In this mode ofoperation the control system will automatically select between the AC and GAS energy sources with AChaving first priority.

Page 7: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

GAS MODEWhen operating in the GAS mode, the mode indicator lamp (E) will illuminate.

The GAS mode provides LP gas operation only. The control system will activate the ignition system andwill attempt to light the burner for a period of approximately 45 seconds. If unsuccessful, the CHECKindicator lamp (G) will illuminate and the gas mode indicator lamp (C) will turn off.

To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position.The control system will attempt a new 45 seconds ignitionsequence.

If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may betrapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFFbutton (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make surethat the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open.

If the control is switched to the AES or AC/GAS mode of operation while the CHECK indicator lamp is on,it will function properly on AC or DC, but if the CHECK indicator lamp is on, it will not go off until the mainpower ON/OFF button is pressed to the OFF then ON position.

BATTERY PROTECTION SYSTEMThe control system is equipped with a battery protection system. If AC power is not available, the controlwill switch to the DC energy source. If the input voltage at the terminal block connections is below 12.8volts, the control system will bypass the DC energy source and attempt GAS operation, If the GASenergy source is available, CHECK lamp is on, the control system will return to the DC energy source.The control will operate in the DC mode for a maximum of 10 minutes.

If the input voltage has not returned above 12.8 volts within this time, the control will terminate DCoperation and turn off the DC lamp (F) and start gas operation if GAS energy source is available andcheck light is not on.

The input battery voltage must rise above 12.8 volts for 25 minutes before DC operation can resume.

As soon as the input voltage rises above the required 12.8 volts, the DC mode lamp (F) will illuminate;however, the control system will remain in the 25 minute delay mode and operate on gas. This delay isto allow sufficient time for the vehicle charging system to recharge the battery. If 120 volt AC becomesavailable during the 25 minute delay, the control will automatically switch energy source.

SPECIAL FEATURES OF OPERATION

This control system contains a feature where it will continue to operate the cooling system in the eventof a failure of a major operating component. Two different modes of operation can occur in this category.

If the display module becomes nonfunctional, the control system will revert to full automatic operationselecting the best energy source available with AC, DC and GAS priority. The temperature of therefrigerator will be maintained at the MID position within normal temperature tolerances. The powermodule will continually attempt to reestablish operation of the display module.

The second Special Feature of operation will execute when a failure of the temperature sensing deviceor associated electronic circuitry occurs. If this should occur, the control system will operate on theenergy source selected via the control panel. The cooling unit will run continuously on the selectedenergy source and could freeze. The refrigerator will continue to operate in this mode indefinitely or untila new sensor is installed and the system is reset.

NOTE: The operational range of these refrigerators is 46°F to 35°F 3”.

Page 8: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

2-WAY DISPLAY PANEL 3-WAY DISPLAY PANEL

D

B C EB C E F

ROYALE REFRIGERATOR OPERATIONMODELS INCLUDE: RM3662, RM3663, RM3662 and RM3863

AUTO MODE (P-WAY MODEL)Press the AUTO mode selector button (2) to the DOWN position. If 120 volts AC is available, the AC modeindicator lamp (B) will illuminate indicating AC operation. If 120 volts AC is not available, the GAS modeindicator lamp (C) will illuminate and the control system will automatically switch to GAS operation.If the CHECK indicator lamp (E) illuminates and the GAS mode indicator lamp (C) is OFF, the controls havefailed to ignite the burner in the GAS mode. GAS operation may be reset by pressing the main power ON/OFF button (1) to the OFF then ON position. (See GAS MODE.)Press the TEMPERATURE SELECTOR button (3) until the lamp at the desired position is illuminated.

GAS MODE (2-WAY MODEL)Move the AUTO mode selector button (2) to the UP position. The GAS mode indicator lamp (C) willilluminate. After 45 seconds the burner should be ignited and operating normally.On the initial refrigerator start-up, it may take longer than 45 seconds to allow air to be purged from thegas line. If the gas does not ignite within 45 seconds, the CHECK indicator lamp (E) will illuminate and theGAS mode indicator lamp (C)will go off. To reset when the CHECK indicator lamp (E) is illuminated, pressthe main power ON/OFF button (1) to the OFF and then ON position.NOTE: DO NOT continue to reset GAS operation if the CHECK indicator lamp continues to beilluminated after several tries.Press the TEMPERATURE SELECTOR button (3) until the lamp (F) at the desired position is illuminated.

AUTO MODE (3-WAY MODEL)Press the DC mode selector button (2) to the UP (OFF) position.

Move the AUTO mode selector button (3) to the DOWN position. If 120 volts AC is available, the ACmode indicator lamp (B) will illuminate indicating AC operation. If 120 volts AC is not available, the GASmode indicator lamp (C) will illuminate and the control system will automatically switch to GAS operation.If the CHECK indicator lamp (E) illuminates and the GAS mode indicator lamp (C) is off, the controls havefailed to ignite the burner in the GAS mode. GAS operation may be reset by pressing the main power ON/OFF button (1) to the OFF then ON position. (See GAS MODE).

Press the TEMPERATURE SELECTOR button (4) until the lamp (F) at the desired position is illuminated.

GAS MODE (3-WAY MODEL)Press the DC mode button (2) to the UP (OFF) position.Move the AUTO mode selector button (3) to the UP position. The GAS mode indicator lamp (C) willilluminate. After 45 seconds the burner should be ignited and operating normally.

On the initial refrigerator start-up, it may take longer than 45 seconds to allow air to be purged from thegas line. If the gas does not ignite within 45 seconds, the CHECK indicator lamp (E) will illuminate and theGAS mode indicator lamp (C) will go off. To reset when the CHECK indicator lamp (E) is illuminated, pressthe main power ON/OFF button (1) to the OFF and then ON position.

Page 9: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

NOTE: DO NOT continue to reset GAS operation if the CHECK indicator lamp continues to beilluminated after several tries.Press the TEMPERATURE SELECTOR button (4) until the lamp (F) at the desired position is illuminated.

DC MODE (3-WAY MODEL ONLY)Press the DC mode indicator button (2) to the DOWN position. (Lamp [A] will light).Press the TEMPERATURE SELECTOR button (4) until the lamp (F) at the desired position is illuminated.The refrigerator will continue to operate in the DC mode until switch (2) is moved to the UP position.

Turn off the refrigerator or move the DC selector button (2) to the UP/OFF position. The DC modeoverrides all the other operating modes. Discharging of the battery will occur if the vehicle engineis not running.

TEMPERATURE SELECTORThe temperature selector on the refrigerator controls both the gas and electric operation, therebyeliminating the necessity of resetting each time a different energy source is employed.

After the initial start-up, the temperature selector should be moved from “COLDEST” to the desiredtemperature setting, which is usually about mid-setting.

TO SHUT OFF THE REFRIGERATORThe refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFF button(1) to the UP (OFF) position. This shuts off all DC power to the refrigerator, including the interior light.

ELITE REFRIGERATOR OPERATION (2-WAY)MODELS INCLUDE: RM4872

2-WAY DISPLAY PANELB

CHECK COLD 1 2 3 4 5 COLDES

IA C D’ E

AUTO MODEPress the Auto mode selector button (2) to the DOWN position. Lamp (B) will illuminate. If 120 volts isavailable, the AC mode indicator lamp (A) will illuminate indicating AC operation. If 120 Volts AC is notavailable, the GAS indicator lamp (C) will illuminate, indicating the control has automatically switched tothe GAS mode.

If the CHECK indicator lamp (D) illuminates and the GAS mode indicator lamp (C) is off, the controls havefailed to ignite the burner in the GAS mode. GAS operation may be reset by pressing the main powerON/OFF button (1) to the OFF then ON position. (See Step 2 under GAS MODE). Press theTEMPERATURE SELECTOR button (3) until the lamp at the desired position is illuminated.

Page 10: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

GAS MODEMove the mode selector button (2) to the UP position. The GAS mode indicator lamp (C) will illuminate.After 45 seconds the burner should be ignited and operating normally.

On the initial refrigerator start-up, it may take longer than 45 seconds to allow air to be purged from thegas line. If the gas does not ignite within 45 seconds, the CHECK indicator lamp (D) will illuminate andthe GAS mode indicator lamp (C) will go off.NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminatedafter several tries.

Press the TEMPERATURE SELECTOR button (3) until the lamp at the desired position is illuminated.

TEMPERATURE SELECTORThe temperature selector on the refrigerator controls both the gas and electric operation, therebyeliminating the necessity of resetting each time a different energy source is employed.

After the initial start-up, the temperature selector should be moved from “COLDEST” to the desiredtemperature setting, usually about mid-setting.

TO SHUT OFF THE REFRIGERATORThe refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFFbutton to the UP (OFF) position. This shuts off all DC power to the refrigerator, including the interior light.

DESCRIPTION OF OPERATING MODESAUTO MODE

When operating in the AUTO mode, the AUTO mode indicator lamp (B) will illuminate. The control systemwill automatically select between AC and GAS operation with AC having priority over GAS. Either theAC indicator lamp (A) or the GAS indicator lamp (C) will illuminate depending on the energy sourceselected by the control system. If the control system is operating with AC energy and it then becomesunavailable, the system will automatically switch to GAS. As soon as AC becomes available again, thecontrol will switch back to AC regardless of the status of GAS operation.

GAS MODEWhen operating in the GAS mode, the AUTO mode indicator lamp (B) will be off and the GAS modeindicator lamp (C) will be illuminated. This mode provides LP gas operation only. The control system willactivate the ignition system and will attempt to light the burner for a period of approximately 45 seconds.If unsuccessful, the CHECK indicator lamp (D) will illuminate and the GAS mode indicator lamp (C) willturn off.

To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position. Thecontrol system will attempt a new 45 second ignition sequence.

If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may betrapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFFbutton (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make surethat the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open.

SPECIAL FEATURES OF OPERATIONThis control system contains a feature where it will continue to operate the cooling system in the event ofa failure of a major operating component. Two different modes of operation can occur in this category.

If for some reason the display module becomes nonfunctional, the control system will revert to fullyautomatic operation - selecting the best energy source available with AC and GAS priority. Thetemperature of the refrigerator will be maintained at the MID position within normal temperature tolerances.The power module will continually attempt to reestablish operation of the display module.

Page 11: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

The second standby mode of operation will execute when a failure of the temperature sensing device orassociated electronic circuitry occurs. If this should occur, the control system will operate on the energysource selected via the control panel. The cooling unit will run continuously on the selected energy source.The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installed and thesystem is reset.

ELITE REFRIGERATOR OPERATION (39WAY)MODELS INCLUDE: RM4873

A 6 C D E

3-WAY PANELDISPLAY

AES/AUTO MODEThe AES/AUTO mode of operation takes priority over all other operating modes. If more than one modeselector button (2), (3) or (4) is in the down position, the priority is from left to right.

When operating in this mode, the AES/AUTO mode indicator lamp (A) will illuminate. In this mode thecontrol system will automatically select the energy source with AC having top priority, DC second priorityand GAS third priority. If the control system has selected a particular energy source such as AC, and thenit becomes unavailable, it will automatically seek out the next available energy source.

Press the AES/AUTO mode selector button (2) to the DOWN position. Indicator lamp (A) should illuminate.Indicator lamp (D), (E) or (F) should also illuminate indicating which energy source the control hasselected.

Press the TEMPERATURE SELECTOR button (5) until the lamp at the desired position is illuminated.

AC/GAS MODEPress the AC/GAS mode selector button (3) to the DOWN (ON) position. Mode indicator lamp (B) shouldilluminate.

In this mode of operation the control system will automatically select between the AC and GAS energysources with AC having first priority.

The AES/AUTO mode selector button (2) must be in the UP (OFF) position.

Indicator lamp (D) or (E) should also illuminate indicating which energy source the control has selected.If the CHECK indicator lamp (G) illuminates, see GAS MODE for further instructions.

Press the TEMPERATURE SELECTOR button (5) until the lamp at the desired position is illuminated.

10

Page 12: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

GAS MODEWhen operating in the GAS mode, the AES/AUTO (2) and AC/GAS (3) mode selector buttons must be inthe UP (OFF) position.

The GAS mode provides LP gas operation only.

Press the GAS mode indicator button (4) to the DOWN (ON) position.

Indicator lamps (C) and (E) should illuminate indicating GAS operation. After45 seconds the burner shouldbe ignited and operating normally.

On the initial refrigerator start-up, it may take longer than 45 seconds to allow air to be purged from thegas line. If the gas does not ignite within 45 seconds the CHECK indicator lamp (G) will illuminate and theGAS indictor lamp (C) and (E) will go off.

To reset when the CHECK indicator lamp (G) is illuminated, press the main power ON/OFF button (1) tothe OFF then ON position.

NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminatedafter several tries. If repeated attempts fail to start the LP gas operation, check to make sure that the LPgas supply tanks are not empty and all manual shutoff valves in the lines are open.

Press the TEMPERATURE SELECTOR button (5) until the lamp (H) at the desired position is illuminated.

If the control is switched to the AES/AUTO or AC/GAS mode of operation while the CHECK indicator lampis on, AC or DC will function properly, but the CHECK indicator lamp will not go off until the main powerON/OFF button is pressed to the OFF then ON position.

TEMPERATURE SELECTORThe temperature selector on the refrigerator controls both the gas and electric operation, therebyeliminating the necessity of resetting each time a different energy source is employed.

After the initial start-up, the temperature selector should be moved from “COLDEST” to the desiredtemperature setting, usually about mid-setting.

TO SHUT OFF THE REFRIGERATORThe refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFF buttonto the UP (OFF) position. This shuts off all DC power to the refrigerator.

DESCRIPTION OF OPERATING MODES

AES/AUTO MODEThe AES/AUTO mode of operation takes priority over all other operating modes. If more than one modeselector button (2), (3) or (4) is in the down position the priority is from left to right.

When operating in the AES/AUTO mode, the AES/AUTO mode indicator lamp (A) will illuminate. In thismode the control system will automatically select the energy source with AC having top priority, DC secondpriority and GAS third priority. If the control system has selected a particular energy source such as AC,and then it becomes unavailable, it will automatically seek out the next available energy source.

AC/GAS MODEWhen operating in the AC/GAS mode, the AC/GAS mode indicator lamp (B) will illuminate.

In this mode of operation the control system will automatically select between the AC and GAS energysources with AC having first priority.

11

Page 13: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

GAS MODEWhen operating in the GAS mode, the GAS mode indicator lamp (C) will illuminate.

The GAS mode provides LP gas operation only. The control system will activate the ignition system andwill attempt to light the burner for a period of approximately 45 seconds. If unsuccessful, the CHECKindicator lamp (G) will illuminate and the GAS mode indicator lamp (C) will turn off.

To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position. Thecontrol system will attempt a new 45 second ignition sequence.

If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may betrapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFFbutton (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make surethat the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open.

If the control is switched to AES/AUTO or AC/GAS mode of operation while the CHECK indicator lamp ison, it will function properly, but the CHECK indicator lamp will not go off until the main power ON/OFF buttonis pressed to the OFF then ON position.

BATTERY PROTECTION SYSTEMThe control system is equipped with a battery protection system. If AC power is not available the controlwill switch to the DC energy source. If the input voltage at the terminal block connections is below 12.8volts the control system will bypass the DC energy source and attempt GAS operation. If the GAS energysource is available, CHECK lamp is on, the control system will return to the DC energy source. The controlwill operate in the DC mode for a maximum of 10 minutes.

If the input voltage has not returned above 12.8volts within this time, the control will terminate DC operationand turn off the DC lamp (F) and start gas operation if GAS energy source is available.The input battery voltage must rise above 12.8 volts for 25 minutes before DC operation can resume.

As soon as the input voltage rises above the required 12.8 volts, the DC mode lamp (F) will illuminate.However the control system will remain in the 25 minute DC delay mode and operate on gas. This delayis to allow sufficient time for the vehicle charging system to recharge the battery. If 120 volt AC becomesavailable during the 25 minute delay, the control will automatically switch to the AC energy source.

STANDBY MODE OF OPERATIONThis control system contains a feature where it will continue to operate the cooling system in the event ofa failure of a major operating component. Two different modes of operation can occur in this category.If for some reason the display module becomes nonfunctional, the control system will revert to fullyautomatic operation - selecting the best energy source available with AC and GAS priority. Thetemperature of the refrigeratorwill be maintained at the MID position within normal temperature tolerances.The power module will continually attempt to reestablish operation of the display module.

The second standby mode of operation will execute when a failure of the temperature sensing device orassociated electronic circuitry occurs. If this should occur, the control system will operate on the energysource selected via the control panel. The cooling unit will run continuously on the selected energy source.The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installed and thesystem is reset.

AC VOLTAGE REQUIREMENTSProper Operating Range is 100 to 132 Volts.

If voltage drops below 100 volts, cooling efficiency will decrease with voltage decrease. The refrigeratorwill not switch to another mode of operation until all AC power is lost.

12

Page 14: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

AC COMPONENTSHEATING ELEMENT

Remove the heater leads from the lower circuit board and measure for proper resistance .

You should obtain the following readings 10%:

MODEL WATTS VOLTS OHMS

S1521 185 120 78

S1531 195 120 78

S1621 325 120 44

S1631 325 120 44

S1821 325 120 44

S1831 325 120 44

RM2607 295 120 48

RM2611 295 120 48

RM2807 325 120 44

RM2811 325 120 44

RM3607 295 120 48

RM3807 325 120 44

RM3662 325 120 44

RM3663 325 120 44

RM3862 325 120 44

RM3863 325 120 44

RM4872 325 120 44

RM4873 325 120 44

DC VOLTAGE REQUIREMENTSThe operational range of the unit is a minimum of 9.6V DC to a maximum of 22V DC, the unit willautomatically shut down until voltage has decreased to 18V DC. The refrigerator requires at least 9.6VDC for proper operation; however the panel lights will continue to illuminate until voltage has dropped to4V DC or below.

Do not use the body or chassis of the RV as a substitute for either of the two conductors. Proper polarityis crucial for refrigerator operation.

13

Page 15: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

DC COMPONENTS -HEATING ELEMENT

Check the heating element with ohms resistance.

You should obtain the following readings 10%:

MODEL WATTS

S1531 215

S1621 215

S1631 215

RM2607 215

RM2611 215

RM2807 215

RM2811 215

RM3607 215

RM3807 215

RM3663 215

RM3863 215

RM4873 215

A continuity reading will indicate an open or complete circuit.

THERMISTORDisconnect the thermistor harness from theP2, 2-pin terminal on the lower circuit board.Place a thermistor in a glass of ice water.Wait 2 to 3 minutes. You should get a readingof approximately 7,000 to 10,000 ohms.

VOLTS OHMS

12 .67

12 .67

12 .67

12 .67

12 .67

12 .67

12 .67

12 .67

12 .67

12 .67

12 .67

12 .67

14

Page 16: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

THERMISTOR ADJUSTERDo an ohms resistance check across the terminals. Proper ohms reading is approximately 23,200 ohms 10%.

THERMISTORADJUSTER

TO THER-MISTORNOTE: Dometic refrigerators do not come equipped with athermistor adjuster. This is an add-on component.

SOLENOID VALVECheck the solenoid with a properly calibrated ohm meter. Remove the connector from the solenoid andmeasure the resistance across the terminals. The proper reading would be 49 ohms with tolerancerange of ten percent.

Next, hook up a manometer at the test port. Then check for DC volts at gas valve terminals while theunit is in trial-for-ianition. If DC volts are present and pressure is low, replace the valve. If DC volts arenot present at the valve while the unit is in trial-for ianition, verify that the wire at Plug 3, Terminal 2 onlower circuit board has DC volts (9 or more).

AMES/AES

REFRIGERATORS

ROYALE AND ELITEREFRIGERATORS

15

Page 17: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

IGNITERVerify proper voltage at the positive (+) and ground (-)terminals of the igniter. Remove high voltage cable froigniter. The igniter should produce a sparking sound duringtrial-for-ianition. The igniter installed on the refrigerators asoriginal equipment is part number 2931132019 (RV GasModel 679). This igniter is rated 50 MA. This igniter mayalso be used on any other model.

DO NOT install the Channel Mark 6, Model 12E Igniter(shown below) as a service replacement part.

r

MARK 6, MODEL 12E

12VDC 25mACHANNEL PRODUCTS

CHESTERLAND OH 44026

Installation of the Channel Products, Inc., Gasliter Mark 6, Model 12E will VOID the Warranty onrefrigerator.

the

HIGH VOLTAGE CABLE

Disconnect high voltage cable from electrode. If sparking starts during trial-for ianition, the cable isgood.

ELECTRODE

Do a visual check for cracks or breaks on the ceramic insulator. If either of the above is found, replacethe electrode. The spark gap must be set at three sixteenths (3/16”) of an inch and tip of electrodeabove the slots in the burner.

16

Page 18: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

UPPER CIRCUIT BOARD

NOTE: The PAL tester will allow for proper testing of the integrity of the upper and lower circuit boards.PAL is available from your Dometic parts distributor.

With main ON/OFF switch on display panel in OFF position:

Check for DC voltage at Plug 1, Terminal 4 (orange or white wire) and terminal 5 (red wire) negative (-)DC on the lower circuit board. If no voltage, then check fuse condition.

UPPER CIRCUIT BOARD

RED 3

ORANGE OR WHITE 4

Check for DC voltage between J4 and J10 terminals on the lower circuit board.

Next, check for DC voltage at the upper circuit board between terminal 4 (orange or white wire) andterminal 3 (red) which is negative (-) DC. If no voltage, and your previous check proved voltage at thelower circuit board between these wires, replace the cable assembly.

With main ON/OFF switch on display panel in O N position:

Check for DC volts between terminal 3, red wire (-) negative and terminal 5 (green wire) and termi-nal 1 (black wire). If there is no voltage, the ON/OFF switch on upper circuit board is defective.

Do the same voltage test at the lower circuit board. (-) negative plug 1, terminal 5 (red wire), plug 1,terminal 1 (green wire) and plug 1, terminal 3 (black wire). If there is no voltage and you had voltageon previous test, the cable assembly is defective.

DIAGNOSTIC MODE

Access to the diagnostic sequence unit: With the Power Switch in the OFF position, hold the Tem-perature Selector Switch in the DOWN position. While keeping the Temperature Selector Switch in theDOWN position, move the main power ON/OFF Switch to the ON (DOWN) position. Hold the Tempera-ture Selector Switch DOWN for three (3) seconds.

The Temperature Indicator Lamps are used to indicate which part of the control system is being tested.When position #1 is illuminated, the control is in an idle position with all output loads off.

All of the checks listed below are done on the lower circuit board.

The manual test sequence is as follows:

Position #l : Idle Position, all loads off.

Position #2: Activate AC Heater. Check for AC volts at terminals J7 and J8.

Position #3: Activate Gas Solenoid. Check for DC volts at Gas Solenoid white wire (-) and yellow wire(+).

Position #4: Activate DC heater. Check for DC volts between J1 (+) and J10 (-).

Position #5: Activate spark ignition system. Check for DC volts to (+) terminal of igniter and ground.

17

Page 19: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

If you experience a problem on any of the above checks, verify the fuses on the lower circuit board aregood.

If all checks prove to be good, and the refrigerator does not operate on electric mode, replace the lowercircuit board. It has been damaged by AC volts in excess of 180 volts.

AES DISPLAY PANELPOWER SWITCH

CHECK

TEMPERATURE SELECTOR SWITCH

LOWER CIRCUIT BOARD

A. DC VOLT: ALL TESTS ARE TO BE DONE WITH THE REFRIGERATOR IN THE COOLING MODE.

Measure volts between terminal J4 and the ground strip. Voltage should be the same as at the positive(+) and negative (-) on the terminal block.

1

B. AC MODE: Check that incoming AC voltage is present at terminals J5 and J6 on the circuit board. Checkfor voltage at the heating element connection terminals J7 and J8 on the circuit board. If no voltage ispresent, check the 5-amp AC and 3-amp DC fuses. If fuses are good, replace the circuit board.

C. DC MODE: Check for voltage between terminal J4 on the circuit board and the ground strip. If voltage is12.8 volts DC or above, check for DC volts between the heating element (J1) connection and the groundstrip. Check the fuses and the DC heating element.

18

Page 20: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

D. GAS MODE: Verify that the following components are good: upper circuit board, thermistor and 3-ampfuse.

Check for voltage during trial-for-ianition at Plug 3, Terminals 1 (white wire) and 2 (yellow wire) tothe solenoid. If no voltage is present, change the circuit board.

Next, check for voltage to the igniter. If no voltage is present, check the wires. If good, then changethe circuit board.

NOTE: When millivolts to the lower circuit board are 10 3, the power to Plug 3, Terminal 4 (bluewire) will be shut off. If flame extinguishes during the cooling mode, the circuit board will not supplyvoltage to Plug 3, Terminal 4 (blue wire) again until the millivolts have decreased to

To check the flame sense circuit of the lower circuit board, operate the refrigerator on GAS mode,then measure the millivolts between J3 terminal and the other wire connection from the thermocouple.The millivolt meter should read between 25 to 35 millivolts with the gas flame burning. Next, turn themanual shutoff valve to OFF and watch the millivolt reading as it drops. Note the millivolt readingwhen Plug 3, Terminal 4 (blue wire) receives power. It should be 3 millivolts or 7 to 13.

DOOR SWITCH (Only on Models Equipped with Interior Lights)

When the switch arm is depressed, there should not be continuity. When the switch arm is NOT de-pressed, there should be continuity.

FUSESThe 3 amp DC fuse is designed to protect the circuit board from internal shorts. The 5 amp AC fuse isdesigned to protect the integrity of the AC heater circuit from shorts. On 3-way models only, the 35 ampDC fuse is designed to protect the DC heater circuit integrity.

CLIMATE CONTROL HEATERDisconnect the wires and do a continuity check. In the OFF position, there should be no continuity. Inthe ON position, there should be a continuity reading.

To check the heater itself, do an ohms resistance reading. The proper ohms reading is 24 ohms 10%.

19

Page 21: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

LP GAS REQUIREMENTSThe LP gas pressure to the refrigerator should be 11 inches water column with half of all BTU’s of theRV turned on. With all other appliances off, the pressure to the refrigerator should not exceed 12 incheswater column. To check the gas pressure when the refrigerator is operating, there is a pressure test porton the solenoid.

LP GAS COMPONENTSMANUAL GAS SHUTOFF VALVETo check the shutoff valve, remove andinspect for any obstructions.

PowerModule.Cover

Test

\

Shutoff ValveFlexible Cord

Gas Connection Orifice

ROYALE & ELITE SILHOUETTE

AMES & AES

PRESSURE TEST PORTTHERMOCOUPLE

\

MANUALGAS

(Shown in“ON” posi-

tion)

AMES & AES

SOLENOID VALVE

MANUAL GAS SHUTOFF (Shown in “ON” position) PRESSURE TEST PORT ORIFICE

20

Page 22: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

ROYALE AND ELITEMODELS MANUAL SHUTOFF VALVE

Use a quarter dollar or a slotted screwdriverto change position

SOLENOID VALVE

THERMOCOUPLE

PRESSURE TEST-PORT

ORIFICEThe orifice is cleaned by using an alcohol based solvent and allowing to air dry.If there is a lack of cooling on gas operation, verify the orifice is the proper size per the chart below:

S1521 #43S1531 #43S1621 #58S1631 #58S1821 #58S1831 #58

RM2607 #53RM2611 #53RM2807 #58RM2811 #58RM3607 #53RM3807 #58

RM3662 #58RM3663 #58RM3862 #58RM3863 #58RM4872 #58RM4873 #58

THERMOCOUPLE

The thermocouple should produce 25 to 35 millivolts when connected to the lower circuit board. Anyreading below 18 millivolts could cause erratic gas operation.

BURNER

The slots in the burner should be directly below the flue tube. The burner should be cleaned periodically,at least once a year. Soak the burner in an alcohol based solvent and allow to air dry.

FLUE BAFFLE

It should be cleaned periodically, at least once a year.

The proper position of the baffle above the burnershould be as follows:

S1521 2-1/4" RM2607 1-5/8"S1531 2-1/4" RM2611 1-5/8"S1621 1-5/8" RM2807 1-3/4"S1631 1-5/8" RM2811 1-3/4"S1821 1-5/8" RM3607 1-5/8"S1831 1-5/8" RM3807 1-3/4"RM3662RM3663RM3862RM3863RM4872RM4873

-7/8"-7/8"-7/8"-7/8"-7/8"-7/8"

21

Page 23: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

FLUE CAP (AMES/AES MODELS ONLY)The flue cap is located at the top of the flue tube and is attached with a screw.

FLUE TUBEFLUE

The flue tube must be cleaned periodically, at least once a year

Clean by using a flue brush, Dometic Part No. 0151404001.

TUBE

WIRING

EXTERNAL WIRING

1.120 Volts AC ConnectionThe refrigerator is equipped with a three-prong (grounded) plug for protection against shock hazardsand should be plugged directly into a properly grounded three-prong receptacle. Do not cut or removethe grounding prong from this plug.

2.12 Volt DC ConnectionThe refrigerator must be connected to the battery circuit with two wires of adequate capacity to avoidvoltage drop.

The wire gauge should be chosen in accordance with the Table shown below.

Do not use the body or chassis of the vehicle as a substitute for either of the two conductors. No otherelectrical equipment or lighting should be connected to the refrigerator circuit.

MAXIMUM CONDUCTOR WIRE LENGTH IN FEET

AWG S 1 5 2 1 S1621 S1621 RM2607 RM2607 RM3662 RM3662 RM4672

S1531 S1631 S1631 RM2611 RM2811 RM3607 RM3607 RM3663 RM3663 RM4673

6 - 27 27 27 27 27 27 27 27 27

10 19 17 17 17 17 17 17 17 17 17

12 I 12 I - - ,_ ,_ ,_- ,_ - - ,_ ,_

22

Page 24: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

INTERNAL WIRINGVerify the refrigerator is wired per the wiring diagram for the exact model you are working on. See thefollowing typical wiring diagrams.

AMES & AESTYPICAL 3-WAY WIRING

DIAGRAM

O_ Circuit Board Power Circuit Board Display Thermistor Gas Valve Reigniter Thermocouple Electrode Retainer for Burner Terminal Block Terminal Strip Absorption Unit Fuse 3A Fuse 5A Heater 120V AC Fuse 35A Heater 12V DC

Heating Cable Switch Terminal BlockTerminal Block

AMES & AESTYPICAL 2-WAY WIRING DIAGRAM

III

Circuit Board PowerCircuit Board DisplayThermistorGas ValveReigniterThermocoupleElectrodeRetainer for BurnerTerminal BlockTerminal StripAbsorption UnitFuse 3AFuse 5AHeater 120V ACSwitchLightHeating CableSwitchTerminal BlockTerminal Block

Page 25: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

ROYALE & ELITETYPICAL 2-WAY

WIRING DIAGRAM

2 9 3 2 6 7 5 0 0

@--BURNER

BOARD DISPLAY BOARD P O WE R

3A 5A

120V AC CABLE

J

EARTH

I 0 VALVE

LIGHT N A L BLOCK

POINT

@---YELLOW

24

Page 26: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

ROYALE & ELITETYPICAL 3-WAY

WIRING DIAGRAM

293267600 HOUSING

@-CIRCUIT BOARD DISPLAY EAR TH

@CIRCUIT BOARD POWER

3A 5A

VALVE

35A LIGHT

BLOCK 12v DC PO I NT

LEVELINGThe absorption design utilizes no mechanical pumps or compressors to circulate the refrigerant within thesystem, so proper leveling must be maintained to provide the correct refrigerant flow. Without properleveling, refrigerant within the cooling unit will collect and stagnate at certain areas. Both Dometic and Servelbrand refrigerators have a type of cooling unit that utilizes an enclosed pump tube surrounded by a solution.The vehicle needs to be leveled so it is comfortable to live in. When the vehicle is moving, leveling is notcritical as the rolling and pitching movement of the vehicle will pass to either side of level, keeping therefrigerant from accumulating in the piping.

25

Page 27: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

VENTILATIONThe coach vent system must be able to provide a way to direct the hot air, produced by the action of thecooling unit, out away from the installation of the refrigerator. In a proper installation, there should be aslittle open space as possible surrounding the sides and top of the refrigerator to achieve proper air flow.

0" CLEARANCEFROM SIDE AND

CLEARANCEFROM

COMBUSTIBLEMATERIALS

PATH OFAIR FLOW

NOTE: Refrigerator should be installed in accordance with appropriate installation instructionsreceived with the refrigerator.

AIR LEAKSCheck the gasket on the doors to be sure of a positive air seal.If a gasket is not sealing properly, first warm the gasket material with a hair drier. Close the door andthe magnetic strip should pull the gasket to themetal frame. Also check that the cooling unitis installed properly.

AMES/AES MODELS:The refrigerator is secured in the enclosurewith six screws and they must be installed inthe following order:

First Two Screws:Installed on the front base.

Second Two Screws:Installed in the top frame.

Third Two Screws:Installed in the rear base.

26

Page 28: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

ROYALE AND ELITE MODELS:CONDENSATE WATER DRAIN HOSE: A 3/4" hole must be drilled through the flooring in the openingof the base plate on the rear of refrigerator.

The refrigerator is secured in the enclosure with six screws. They must be installed in the following order:First: Two screws are installed in front decoration strip and through the front base.A. The front strip is to be installed after the refrigerator is set into the alcove.B. Install the lower front strip by sliding it under the bottom hinge plate as shown.

C. When the front strip is in place, install one screw through the hinge and into the floor. The secondscrew is installed with a washer on the opposite side.

Second: Install the two screws in the top frame.A. The top decoration panel must be removed from the refrigerator Open refriaerator door and gently

push the tabs out of the hole in the hinge with a flat blade screwdriver.B. Carefully tilt the top decoration panel and lift up to remove from top frame.C. Install the second two screws in the top frame as shown.

27

Page 29: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

D. Replace the top decoration panel.

Third: Two screws installed as shown in rear base.

DOOR POSITIONThe door position can be checked by observing any misalignment of the door in relation to the frame.

To adjust either door, loosen the hinge bracket screws, reposition the door then tighten the hinge bracketscrews. To adjust up or down, add or remove washers from the lower hinge pin.

AMBIENT TEMPERATUREAs the ambient temperature increases, the air temperature in the area of the cooling unit increases. Thedouble-door refrigerators should maintain approximately 43 degrees food storage temperature at 110degrees ambient temperature.

Page 30: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

COOLING UNITThe chemicals involved in the cooling process include hydrogen, ammonia, water, and a rust inhibiting agent.There are no repairs recommended on the cooling unit.

TO DIAGNOSE ALL COOLING UNITSModels RM3662, RM3663, RM3862, RM3863, RM4872, RM4873After four hours of operation, feel the back plate of the freezer section. It should be cold to the touch. If coldto the touch, the unit is working.

If after four hours of operation the unit back plate is not cold to the touch, turn the refrigeratorto OFF; wait 1 -1/2hours and restart the refrigerator. After four hours of operation the back plate of the freezer section shouldbe cold to the touch. If it is not cold to the touch after the second four hours of operation, the cooling unit maybe defective.

Verify the AC heating element is good. Then place approximately one gallon of water inside the refrigeratorand place a thermometer in one of the containers of water. Next, supply 115 volts direct to the AC heatingelement and operate for at least 12 hours. Check the temperature on the thermometer. It should be 45 degreesor lower, depending on test conditions.

FOOD STORAGEIt is essential that the shelves are not covered with paper or large storage containers. Always remember toallow for proper air circulation.

Odorous or highly flavored foods should always be stored in covered dishes, plastic bags, or wrapped in foilor waxed paper to prevent food odors. Vegetables, lettuce, etc., should be covered. NEVER PUT HOT FOODINTO THE REFRIGERATOR.

HIGH HUMIDITYThe condensation may actually run off the frame. As the humidity is reduced, the “sweating” will decrease.

INTERIOR LINER SEAL TO FRAMECondensation could form on the frame and could promote rapid formation of frost. Apply a small bead ofsilicone all the way around the perimeter where the frame meets the interior liner.

Slide the refrigerator out approximately 2-4 inches. Apply a foil-backed adhesive tape to the joint betweenouter frame and foil-backed refrigerator insulation.

NOTE: TO FORM A PROPER SEAL, IT IS IMPORTANT NOT TO LEAVE ANY GAPS.

PLASTIC LINER

doors removed)

29

Page 31: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

ICE MAKER OPERATION

The refrigerator must be allowed to precool properly before starting the ice maker. The refrigerator has tobe connected to 120 volts AC before the ice maker can operate. The water line manual shutoff valve mustbe open. To start making ice, move the ice level bail arm to DOWN position.

ICE LEVEL BAIL ARM

DOWN POSITION

When the ice maker thermostat senses the preset temperature for ejection of the ice cubes, the fingers willstart to rotate - dumping any ice cubes and filling the mold with water.

When the storage container is full of ice, the ice level bail arm can not return to the DOWN position. Thiswill stop further production of ice until the container is emptied and the bail arm is returned to the downposition.

The absorption system will keep the compartment at the proper temperature for storage of ice. Icemaking is accelerated if the thermostat is set to the coldest position. It is a good idea to do this a fewhours before you anticipate a need for ice.

NOTE: IF THE ICE MAKER WAS CLEANED AND DRAINED, NO ICE CUBES WILL BE DUMPEDINTO THE STORAGE CONTAINER DURING THE FIRST CYCLE.

The first few cycles may have small cubes due to air trapped in the water lines. The first container of icetubes should be dumped if the water system has been winterized or not used for several weeks.

ICE MAKER COMPONENTS

MOLD HEATERThe mold heater uses 165 watts to thaw the ice free from the mold.It is wired in series with the thermostat which also acts as a safetydevice. You should obtain a reading of approximately 80 ohms. Ifthe heater is found to be defective, the manufacturer recommendsreplacement of the entire ice making unit for proper operation.

ICE EJECTOR

(Staked in Place)

The ice ejector blades sweep the ice from the mold cavities during the ejection cycle.

The drive end of the ejector is “D” shaped for positive coupling. The bearings atboth ends are lubricated with silicone grease If the ejector blades are frozen intothe ice, defrost the ice maker and manually cycle the ice making unit,making sure the ejector stops at the right location.

“D” SHAPED

30

Page 32: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

MOLD THERMOSTATThis is a single-pole, single-throw, bimetal switch. It starts an ejection cycle by closing at 18°F 5”. Thereset temperature is The thermostat is in series with the mold heater and acts as a safetyagainst overheating in case of a mechanical failure.

THERMOSTAT

SHUTOFF ARMThe shutoff arm is cam driven. It operates a switch to control the quantity of ice produced. During theejection cycle the arm is raised and lowered during each of the two revolutions of the timing cam. Thearm has a manual shutoff built into the linkage; by raising the arm as high as possible, it will lock in thatposition until forced down.

MOLD SWITCHESThese three switches are single-pole, double-throw style. They are identical and interchangeable.

The holdina switch assures completion of a revolution once a cycle has started.The water valve switch opens the water valve during the fill stage of the cycle. NOTE: This is theonly adjustable component of the ice maker. If you use a double-throw switch, DO NOT use the N.O.terminal.The shutoff switch stops the ice maker’s operationwhen the storage bin is full.

FRONT VIEWMOTOR

TIMING CAM I I\\

WATERVALVESWITCH

HOLDING SWITCH

31

Page 33: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

TIMING MOTOR

This is a low-wattage, stall-type motor which is geared to the timing cam and ice ejector. It is a one RPMmotor.

Disconnect power to the appliance and test for continuity between the two leads.

WATER VALVE

This valve is solenoid operated. When it is open, it releases water from the source to the mold. Theamount of water is proportional to the length of time the water valve switch is held closed by its timingcam.

Check for continuity between the two terminals. If you have continuity, the solenoid is good. It takes 10-15 watts to energize the solenoid coil. The mold heater and coil are in series. When the mold heater isactivated, this causes the voltage to drop to about 105 VAC at the coil.

The valve has a flow washer inside which acts as a pressure regulator. A strainer is installed to preventdirt, rust, etc. from entering the valve.

WATER VALVE

VALVE BODY

STRAINER

ICE MAKER ASSEMBLY

Check each wire for continuity to make sure the wiring is good before replacing the ice maker unit,

OPERATION

While the operation of the ice maker is fairly simple, an understanding of its cycle is necessary for theservice technician to diagnose specific problems.

The following series of electrical schematics (on the following pages) will show a typical cycle, and the

positions of various components during the cycle: the mold and its contents, the ejector, the shutoff armand the storage bin.

32

Page 34: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

NOTE THE RELATIVE POSITIONOF THESE COMPONENTS IN THEFOLLOWING SCHEMATICS

EJECTOR

NON ENERGIZED ENERGIZED

THERMOSTAT HEATER

This is a freeze Cycle. The mold istilled with water. The thermostat isopen. All components are de-energized.

115VOLTS60 CYCLE

THERMOSTATMOLD

_

This is the start of an ejection cycle.The thermostat switches to its closedposition after being sufficiently cooledby the ice in the mold. The moldheater and motor are now energized.The ejector blades begin to turn.

THERMOSTAT

After a few degrees of motor rotation,the timing cam switches the holdingswitch to its normally open position;this assures completion of the cycle.The mold heater remains energizedthrough the thermostat circuit duringthe first half of the cycle the shut-offarm is raised and lowered by thetiming cam and operates the shut-offswitch.

115VOLTS60 CYCLE

MOLD HEATER

HOLDING

When the ejector blades reach the ICEice in the mold, the motor will stall. Itwill remain in this position until the icehas thawed loose. During this timethe mold heater remains energized.

33

Page 35: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

L

SHUT-OFF SWITCH THERMOSTAT

WATERSOLENOID SWITCH

Near the completion of the firstrevolution, the timimg cam closes thewater valve switch. However, sincethe thermostat is still closed the moldheater circuit is energized. currentwill not pass through the water valvesolenoid and its switch. (Electricalcurrent follows the path of leastresistance.)

At the end of the first revolution thetiming cam opens the holding switch.However, since the thermostat is stillclosed a second revolution begins.

SHUT-OFF SWITCH THERMOSTATMOLD HEATER

HOLDING SWITCH

Once again after a few degrees ofrotation the timing cam closes theholding switch providing a circuit toths motor that will assure completionof this revolution. The mold heaterremains energized. The shut-off armwill raise and lower again operatingits switch. The ice that was ejectedduring the first revolution is dumpedinto the storage bin.

SHUT-OFF SWITCH THERMOSTATMOLD HEATER

WATERSOLENOID SWITCH

HOLDING SWITCH

Some time during the secondrevolution the mold heater resets thethermostat. At this time, the moldheater is de-energized if the storagebin is full, the shut-off arm will remainin a raised position.

34

Page 36: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

SHlJT-OFF SWITCH THERMOSTATMOLD HEATER

HOLDING SWITCH

Near the completion of the secondrevolution the timing cam againcloses the water valve switch. Thistime a circuit is completed throughthe water valve solenoid its switchand the mold heater. The water valvesolenoid received about 105 volts.The remaining 10 volts to the moldheater are not noticeable. When thewater valve solenoid is energized, thevalve opens and water refills themold.

SHUT-OFF MOLD HEATER

The ejection cycle ends the momentthat the holding switch is switched bythe timing cam. The water valveswitch is also opened. If the storagebin is full, as shown here, additionalcycles will not start until sufficient iceis used to lower the shut-off arm,thus operating its switch.

ICE MAKER - OTHER

WATER FILL ADJUSTMENT

The size of the ice cubes depends on the amount of water which enters the mold. The cubes should beapproximately 1/2" wide, 3/4" high and 2-1/2" long.

If the water overflows in the mold, first check to see if the ice maker unit is level in the appliance. Nextensure that the appliance is installed level in the RV.

If there is still water overflow, adjustment of the water fill screw is necessary. Locate the screw on theice maker assembly. Turn the screw as necessary toward the "+" or "-" side. One full turn of the screwwill make an 18cc change in the amount of water. DO NOT turn the screw more than one full turn at atime.

If the water level is too high, it can also cause the ejector blades to become frozen in the ice. Follow theprocedures above to correct the problem.

WATER FILL ADJUSTING SCREW

1 FULL TURN = 18 cc’s CHANGE

35

Page 37: AMES/AES/ROYALE/ELlTE REFRIGERATORSrvrefrigeratorrepair.com/wp-content/uploads/2016/07/Dometic-Service-AMES.pdfAES MODE 3-WAY AES DISPLAY PANEL The AES mode of operation takes priority

WIRING

Refer to the wiring diagram supplied with the unit you are working on, and make sure all wiring connec-tions are correct and tight.

THIS IS AN ENERGIZED CIRCUIT. ELECTRICAL SHOCK CAN OCCUR.

BEFORE CHECKING THESE COMPONENTS BE SURE THERE IS NO POWER TO THE APPLIANCE.

AMES & AESICE MAKER TYPICAL WIRING DIAGRAM

MOUNTING PLATE MOLD SUPPORT

BLUE

ROYALE/ELITE ICE MAKER TYPICAL WIRING DIAGRAM

WIRING DIAGRAM

WATER SUPPLYThe water pressure in the water supply line must be between 15 Ibs. PSI and 125 Ibs. PSI.

Lower water pressure, water turned off, or obstructions or air in the water line can cause low or no iceproduction.

36