Base Station Alarms (7000-7999) DN9813099 Issue 22-0 en 07/03/2008 # Nokia Siemens Networks 1 (1095) BSC3153 Nokia GSM/EDGE BSS, Rel. BSS13, BSC and TCSM, Rel. S13, Product Documentation, v.1
1095
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Alarm

Base Station Alarms (7000-7999)

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1 (1095)

BSC3153Nokia GSM/EDGE BSS, Rel. BSS13, BSC andTCSM, Rel. S13, Product Documentation, v.1

Page 2: Alarm

The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.

The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given “as is” and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. NokiaSiemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA, THAT MAYARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark ofNokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2008. All rights reserved.

2 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 3: Alarm

Summary of changes

Changes between document issues are cumulative. Therefore, the latestdocument issue contains all changes made to previous issues.

Changes made between issues 22-0 and 21-3

New alarms

Alarm 7770 AUTOMATIC UNLOCK OF BCF FAILED has been addedbecause of the feature BSS20847: Automatic commissioning of the FlexiEDGE BTS.

Modified alarms

. 7600 BCF FAULTY

. 7606 TRX FAULTY

. 7727 TRAFFIC CHANNEL NUMBER DECREASED

. 7730 CONFIGURATION OF BCF FAILED

. 7740 BEATING BTS ALARM

. 7769 FAILURE IN UPDATING CELL SPECIFIC PARAMETERS TOPCU

. 7801 MMI CONNECTED TO BASE STATION

Removed alarms

Alarm 7760 FAILURE IN PACKET SYSTEM INFORMATION SENDINGhas been removed because the PBCCH/PCCCH channels are no longersupported. It has been replaced with the alarm 7769 FAILURE INUPDATING CELL SPECIFIC PARAMETERS TO PCU.

Changes made between issues 21-3 and 21-2

Modified alarms

The following alarms have been updated because of the featureBSS21261: Flexi EDGE Dual TRX Manual Power Down:

. 7722 ERROR IN BSS RADIO NETWORK DATABASE UPDATE

. 7723 FAILURE IN SENDING SYSTEM INFORMATION TO BTSSITE

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 3 (1095)

Summary of changes

Page 4: Alarm

. 7724 CONFLICT BETWEEN BSS RADIO NETWORK DATABASEAND CALL CONTROL

. 7760 FAILURE IN PACKET SYSTEM INFORMATION SENDING

Changes made between issues 21-2 and 21-1

Modified alarms

The following alarms have been updated because of the featureBSS21279: Flexi EDGE BTS Feederless Site.

7600 7601 7602 7605

7606 7607 7608 7801

4 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 5: Alarm

1 List of Alarms

7001 TRX/FU: CHECKSUM ERROR IN PRIMARY CU-FULINK

7002 TRX/FU:CHECKSUM ERROR IN REDUNDANT/DIVERSITY CU-FU LINK

7003 TRX/FU: NO DATA FROM FU TO CU

7004 TRX/FU: FORMAT ERROR IN DATA FROM FU TOCU

7005 TRX/FU: CHECKSUM ERROR IN FU-CU LINK

7006 TRX/FU: NO DATA FROM DSPx TO FUCx

7007 TRX/FU: TOO MANY BYTES IN DATA FROM DSPxTO FUCx

7008 TRX/FU: NO DATA FROM CU TO FU IN PRIMARYLINK

7009 TRX/FU: NO DATA FROM CU TO FU INREDUNDANT/DIVERSITY LINK

7010 TRX/FU: BIE-FUCx LINK A FAILURE

7011 TRX/FU: BIE-FUCx LINK B FAILURE

7012 TRX/FU: BIE-FUCx LINK A AND B FAULTY

7013 TRX/FU: BIE-FUCx LINK A DRIVER FAILURE

7014 TRX/FU: BIE-FUCx LINK B DRIVER FAILURE

7016 TRX/FU: GSM TIMESLOT UNATTAINABLE

7017 TRX/FU: FAILURE IN BASE STATION INTERFACE

7020 TRX/FU: MCLx1-FUCx LINK FAILURE

7021 TRX/FU: MCLx2-FUCx LINK FAILURE

7022 TRX/FU: BOTH MCLx-FUCx LINKS FAILURE

7023 TRX/FU: FUCx INTERNAL CLOCK FAILURE

7024 TRX/FU: PARITY ERROR IN INCOMING FN

7030 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU1

7031 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU2

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 5 (1095)

List of Alarms

Page 6: Alarm

7032 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU3

7033 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU4

7034 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU5

7035 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU6

7036 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU7

7037 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU8

7038 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU9

7039 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU10

7040 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU11

7041 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU12

7042 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU13

7043 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU14

7044 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU15

7045 TRX/FU: DATA TRANSFER ERROR BETWEEN FUAND CU16

7050 TRX/FU: DISCREPANCY OF THE FRAMENUMBER BETWEEN FUCx AND DSPx

7051 TRX/FU: CIPHERING CAPABILITIES OF DSPxs INONE TRX DIFFER

7052 TRX/FU: DSPx, ENCRYPTION ALGORITHM A5/1CAN NOT BE EXECUTED

7054 TRX/FU: TRX DOES NOT SUPPORT HALF RATE(TCH/H) CONFIGURATION

7060 TRX/FU: FUCx-DSPx, NO RESPONSE FROMDSPx

7061 TRX/FU: FUCx-DSPx, ILLEGAL SIGN TYPE INSIM-MESSAGE

7062 TRX/FU: FUCx-DSPx, ILLEGAL CHAN COMB INTSC-MESSAGE

6 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 7: Alarm

7063 FUCx-DSPx, ILLEGAL TIME SLOT No. IN TSC-MESSAGE

7064 TRX/FU: FUCx-DSPx, ILLEGAL SUBCHANNEL No.IN SIM-MESSAGE

7065 TRX/FU: FUCx-DSPx, ILLEGAL SUBCHANNEL No.IN HL1-MESSAGE

7066 TRX/FU: FUCx-DSPx, ILLEGAL SUBCHANNEL No.IN CHC-MESSAGE

7067 TRX/FU: FUCx-DSPx, NO FRAME NUMBER FROMDSPx

7068 TRX/FU: DSPx, NO RESULT FROM DSP BOARDTEST

7069 TRX/FU: TRAFFIC SPEED CABABILITIES OF DSPUNIT DIFFER IN TRX

7100 BCF/RFTE: HIGH SIGNAL LEVEL (>-70 DBM) INTHE RFTE OUTPUT

7101 BCF/RFTE: SYNTHESIZER NOT LOCKED OR REFFREQ 1&2 MISSING

7102 BCF/RFTE: SELF TEST FAILURE

7103 BCF/RFTE: MCLx1-RFTE CLOCK FAILURE

7104 BCF/RFTE: MCLx2-RFTE CLOCK FAILURE

7105 BCF/RFTE: MCLx1-RFTE OCTAL BIT CLOCKFAILURE

7106 BCF/RFTE: MCLx2-RFTE OCTAL BIT CLOCKFAILURE

7107 BCF/RFTE: MCLx1-RFTE REFERENCEFREQUENCY FAILURE

7108 BCF/RFTE: MCLx2-RFTE REFERENCEFREQUENCY FAILURE

7109 BCF/RFTE: NO PARAMETERS GIVEN TO UNIT

7110 BCF/RFTE: OMU-RFTE CONNECTION FAILURE

7120 TRX/CU: TXUx - FQHU INTERFACE 1 FAILURE

7121 TRX/CU: TXUx - FQHU INTERFACE 2 FAILURE

7122 TRX/CU: RXUA SELF TEST FAILURE

7123 TRX/CU: DIVERSITY RXUA SELF TEST FAILURE

7124 TRX/CU: HARDWARE FAILURE IN RXUA

7125 TRX/CU: HARDWARE FAILURE IN DIVERSITYRXUA

7126 TRX/CU: RXUA SYNTHESIZER NOT LOCKED

7127 TRX/CU: DIVERSITY RXUA SYNTHESIZER NOTLOCKED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 7 (1095)

List of Alarms

Page 8: Alarm

7128 TRX/CU: TXUx - COMBINER CONNECTIONFAILURE

7129 TRX/CU: TXUx OUTPUT POWER DECREACED

7130 TRX/CU: TXUx LOWER TEMPERATURE ALARM

7131 TRX/CU: TXUx TEMPERATURE TOO HIGH

7132 TRX/CU: TXUx SYNTHESIZER NOT LOCKED,

7133 TRX/CU: MCLx1 - TXUx FRAME CLOCK FAILURE

7134 TRX/CU: MCLx2 - TXUx FRAME CLOCK FAILURE

7135 TRX/CU: MCLx1 - TXUx OCTAL BIT CLOCKFAILURE

7136 TRX/CU: MCLx2 - TXUx OCTAL BIT CLOCKFAILURE

7137 TRX/CU: MCLx1 - TXUx REFERENCEFREQUENCY FAILURE

7138 TRX/CU: MCLx2 - TXUx REFERENCEFREQUENCY FAILURE

7139 TRX/CU: NO PARAMETERS GIVEN TO UNIT

7140 TRX/CU: EXTENDED RANGE CELL NOTSUPPORTED

7141 TRX/CU: INVALID RADIUS EXTENSION OFEXTENDED RANGE CELL

7150 BCF/MCLx: 13 MHZ FREQUENCY FROM OVENOSCILLATOR MISSING

7151 BCF/MCLx: OVEN OSCILLATOR FAILURE

7152 BCF/MCLx: 13 MHZ FREQUENCY FROMREDUNDANT UNIT MISSING

7153 BCF/MCLx: LOSS OF SYNCHRONIZATIONBETWEEN MASTER CLOCK UNITS

7154 BCF/MCLx: FAILURE IN LINK BETWEEN TWOMCLx

7156 BCF/MCLx: FAILURE IN CLOCK OUTPUTDRIVERS

7157 BCF/MCLx: NO PARAMETERS GIVEN TO UNIT

7158 BCF/MCLx: MASTER CLOCK OVEN WARMINGFAILURE

7159 BCF/MCLx: PCM BASED AUTO TUNING OUT OFRANGE

7160 BCF/MCLx: LOSS OF PCM-SYNCHRONIZATION

7161 BCF/MCLx: PCM IS NOT USED TO TUNE MASTERCLOCK

7162 BCF/MCLx: MASTER CLOCK FAST TUNING INPROGRESS

8 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 9: Alarm

7163 BCF/MCLx: DIFFERENCE IN FREQUENCIESBETWEEN PCM AND MCLx

7164 BCF/MCLx: MASTER CLOCK UNIT HARDWAREFAULTY

7170 BCF/FQHU: MCLx1-FQHU PARITY ERROR

7171 BCF/FQHU: MCLx2-FQHU PARITY ERROR

7172 BCF/FQHU: SELF TEST FAILURE

7173 BCF/FQHU: MCLx1-FQHU FRAME CLOCK ISMISSING

7174 BCF/FQHU: MCLx2-FQHU FRAME CLOCK ISMISSING

7175 BCF/FQHU: MCLx1-FQHU OCTAL BIT CLOCK ISMISSING

7176 BCF/FQHU: MCLx2-FQHU OCTAL BIT CLOCK ISMISSING

7177 BCF/FQHU: NO PARAMETERS GIVEN TO UNIT

7190 BTS/RTC: NO PARAMETERS GIVEN TO UNIT

7191 BTS/RTC: ISOLATION FAILURE IN COMBINERINPUTS

7192 BTS/RTC: TUNING IN PROCESS

7193 TRX/RTC: TUNING FAILED

7194 BTS/RTC:TX ANTENNA PERFORMANCEDEGRADED

7195 BTS/RTC:TX ANTENNA FAULTY

7196 TRX/RTC: CARRIER NOT PRESENT

7197 TRX/RTC: FILTER OUT OF CONTROL

7198 BTS/RTC: POWER SUPPLY 1 FAULT

7199 BTS/RTC: POWER SUPPLY 2 FAULT

7200 BCF/EACB: SELF TEST FAILURE

7201 BCF/EACB: NO PARAMETERS GIVEN TO UNIT

7202 BCF/EACB: OMU-EACB CONNECTION FAILURE

7203 BCF/OMU: FAILURE DURING THE INITIALIZATION

7204 BCF/MCLx: MASTER CLOCK UNIT FAULTY

7205 BCF/OMU: PASSWORD WAS CHANGED

7206 BCF/BIE: USER LOGIN

7207 BCF/OMU: HW DATABASE CHANGED

7208 LOCAL BLOCK

7209 BTS/RTC: NO BCCH TRANSMISSION ACTIVATED

7210 BCF/OMU: NO RESPONSE FROM THE UNIT

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 9 (1095)

List of Alarms

Page 10: Alarm

7211 BCF/OMU: REINITIALIZATION OF THE UNITFAILED

7212 BCF/OMU: NO HW DATABASE IN FLASHMEMORY

7214 BCF/OMU: TBUS INITIALIZATION ERROR

7215 BCF/OMU: TBUS SELF TEST ERROR

7216 BCF/OMU: TBUS DRIVER FAULTY

7217 BCF/OMU: TBUS MODEM FAULTY

7218 BCF/OMU: TBUS START OPERATING ERROR

7220 RADIO LOOP OR RX ANTENNA TESTEXECUTION

7221 BTS/ RECEIVER ANTENNA TEST, ANTENNAPERFORMANCE DEGRADED

7222 BTS/ RECEIVER ANTENNA TEST, ANTENNAFAULTY

7223 BCF/OMU: FLASH MEMORY ERROR

7224 TRX SWITCHOVER

7225 BCF/OMU: BACKUP DEVICE FAULTY

7226 BCF/OMU: SW DOWNLOAD FAILURE

7251 BCF/BIE: BLOCKED FROM USE

7252 BCF/BIE: LOOP TO INTERFACE

7253 BCF/BIE: LOOP TO EQUIPMENT

7254 BCF/BIE: TEST MODE

7255 BCF/BIE: LOSS OF INCOMING 2M SIGNAL

7256 BCF/BIE: ALARM INDICATION SIGNAL (AIS) 2MRECEIVED

7257 BCF/BIE: LOSS OF FRAME ALIGNMENT

7258 BCF/BIE: LOSS OF MULTIFRAME ALIGNMENT

7259 BCF/BIE: CRC MULTIFRAME ALIGNMENT LOST

7260 BCF/BIE: BIT ERROR RATE (BER) > 1E-3

7261 BCF/BIE: BIT ERROR RATE (BER) > 1E-4

7262 BCF/BIE: BIT ERROR RATE (BER) > 1E-6

7263 BCF/BIE: FREQUENCY ERROR

7264 BCF/BIE: SYNCHRONIZING FAULT

7265 BCF/BIE: SYNCHRONIZING FAULT IN CLOCKRECOVERY

7266 BCF/BIE: FAULT IN EQUIPMENT

7267 BCF/BIE: MEMORY FAULT

7268 BIE FAULT IN AIS OSCILLATOR

7269 BCF/BIE: MISSING UNIT

10 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 11: Alarm

7270 BCF/BIE: FORCED CONTROL ON

7271 BCF/BIE: INSTALLATION ERROR

7272 BCF/BIE: FORCED INDICATION

7273 BCF/BIE: EQUIPMENT RESET

7274 BCF/BIE: FAULT IN TRANSMITTER

7275 BCF/BIE: RUN DIAGNOSTICS TEST

7276 BCF/BIE: ALARM INDICATION SIGNAL (AIS)RECEIVED ON TIMESLOT 16

7277 BCF/BIE: FAR-END ALARM 1

7278 BCF/BIE: MULTIFRAME ALARM FROM FAR-END

7279 BCF/BIE: FAR END ALARM

7280 BCF/BIE: LOSS OF INCOMING 1.5M SIGNAL

7281 BCF/BIE: AIS 1.5M

7282 BCF/BIE: LOOPED SIGNAL RECEIVED

7283 BCF/BIE: LOSS OF SIGNALLING FRAME

7284 BCF/BIE: EXCESSIVE ERROR RATE

7285 BCF/BIE: FAULT IN INCOMING SIGNAL

7286 BCF/BIE: CONVERTER RESET

7287 BCF/BIE: CONVERTER FAULT

7288 BCF/BIE: YELLOW ALARM

7291 BCF/STM: SELF TEST FAILURE

7292 BCF/STM: INTERNAL I/O-BUS FAILURE

7293 BCF/STM: UNEXPECTED COMMAND FROM OMU

7294 BCF/STM: INTERNAL MEMORY TEST FAILURE

7301 BTS/RXFE: LOW NOISE AMPLIFIER 1 FAILURE

7302 BTS/RXFE: LOW NOISE AMPLIFIER 2 FAILURE

7303 BTS/RXFE: RELAY 1 IS SET TO POSITION 1

7304 BTS/RXFE: RELAY 2 IS SET TO POSITION 1

7305 BTS/RMCx: RMCx FAILURE, ONE AMPLIFIERFAULTY

7306 BTS/RMCx: RMCx FAILURE, BOTH AMPLIFIERSFAULTY

7307 BTS/RMCx: DIVERSITY RMCx FAILURE, ONEAMPLIFIER FAULTY

7308 BTS/RMCx: DIVERSITY RMCx FAILURE, BOTHAMPLIFIERS FAULTY

7309 BTS/TRFE: TOWER FRONT END FAILURE

7310 BCF/CCFU: CABINET COOLING FAN UNITFAILURE

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 11 (1095)

List of Alarms

Page 12: Alarm

7311 BCF/SUPx: STATION UNIT POWER SUPPLYMAINS FAILURE

7312 BCF/SUPx: STATION UNIT POWER SUPPLYOUTPUT FAILURE

7313 BCF/BBUx: BATTERY BACK-UP UNIT MAINSFAILURE

7314 BCF/BBUx: BATTERY BACK-UP UNIT OUTPUTVOLTAGE FAILURE

7315 BCF/BBUx: BATTERY FAILURE

7316 TRX/XUPx: POWER SUPPLY MAINS FAILURE

7317 TRX/XUPx: POWER SUPPLY OUTPUT FAILURE

7318 BTS/ WBCx: TX ANTENNA PERFORMANCEDEGRADED

7319 BTS/WBCx: TX ANTENNA FAULTY

7320 BTS/MHPA: MASTHEAD PREAMPLIFIER FAULTY

7321 BTS/AFLx: ANTENNA FILTER AND LOW NOISEAMPLIFIER FAULTY

7322 BTS/AFLx: DIV.ANTENNA FILTER AND LOWNOISE AMPLIFIER FAULTY

7323 BTS/AMUx: TX ANTENNA PERFORMANCEDEGRADED

7324 BTS/AMUx: TX ANTENNA FAULTY

7325 DOOR IS OPEN IN REMOTE CABINET

7326 HEAT EXCHANGER FAULTY IN REMOTECABINET

7327 HEAT EXCHANGER FAULTY IN LOCAL CABINET

7328 OPTICAL LINK TO REMOTE HEAD FAULTY

7329 OPTICAL LINK FROM REMOTE HEAD FAULTY

7330 OVER TEMPERATURE IN REMOTE HEAD

7331 TEMPERATURE CONTROLLING DEVICE FAULTY

7332 BCF:HEAT EXCHANGER POWER SUPPLYOUTPUT FAILURE

7401 EXTERNAL AL 1

7402 EXTERNAL AL 2

7403 EXTERNAL AL 3

7404 EXTERNAL AL 4

7405 EXTERNAL AL 5

7406 EXTERNAL AL 6

7407 EXTERNAL AL 7

7408 EXTERNAL AL 8

7409 EXTERNAL AL 9

12 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 13: Alarm

7410 EXTERNAL AL 10

7411 EXTERNAL AL 11

7412 EXTERNAL AL 12

7413 EXTERNAL AL 13

7414 EXTERNAL AL 14

7415 EXTERNAL AL 15

7416 EXTERNAL AL 16

7417 EXTERNAL AL 17

7418 EXTERNAL AL 18

7419 EXTERNAL AL 19

7420 EXTERNAL AL 20

7421 EXTERNAL AL 21

7422 EXTERNAL AL 22

7423 EXTERNAL AL 23

7424 EXTERNAL AL 24

7425 EXTERNAL AL 25

7426 EXTERNAL AL 26

7427 EXTERNAL AL 27

7428 EXTERNAL AL 28

7429 EXTERNAL AL 29

7430 EXTERNAL AL 30

7500 BCF/ : CABINET TEMPERATURE ALARM

7501 BCF/ CABINET DOOR OPEN

7502 BCF/ : CABINET TEMPERATURE CONTROLSYSTEM FAILURE

7503 FAULT IN DBUS INTERFACE OF TRX

7504 FAULT IN ABIS INTERFACE OF TRX

7505 FAULT IN TRX CONTROLLER

7506 FAULT IN TRX SERVICE INTERFACE

7507 INTERNAL COMMUNICATION FAILURE IN TRX

7508 RADIO TIMESLOT FAILURE IN TRX

7509 RADIO TIMESLOT FAILURE IN TRX

7510 ABIS TESTLOOP FAILURE IN TRX

7511 RADIO TESTLOOP FAILURE IN TRX

7512 FRAME CLOCK INTERFACE FAILURE

7513 FRAME CLOCK IS MISSING IN TRX

7514 13 MHZ CLOCK IS MISSING IN TRX

7515 FAILURE IN CONNECTION TO FREQUENCYHOPPING

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 13 (1095)

List of Alarms

Page 14: Alarm

7516 DATA TRANSFER FAILURE IN FREQUENCYHOPPING DETECTED BY TRX

7517 FAILURE IN LOCAL TEST DATA IN FREQUENCYHOPPING

7518 FAILURE IN REMOTE TEST DATA INFREQUENCY HOPPING

7519 FAULT IN POWER CONTROL MEMORY

7520 FAULT IN WATCH-DOG OF TRX

7521 TRX TEMPERATURE INCREASED

7522 TRX TEMPERATURE HIGH

7523 TRX TEMPERATURE DANGEROUSLY HIGH

7524 TX FREQUENCY TUNER OUT OF ORDER

7525 TX MAIN FREQUENCY TUNER OUT OF ORDER

7526 RX FREQUENCY TUNER OUT OF ORDER

7527 RX MAIN FREQUENCY TUNER OUT OF ORDER

7528 TEST LOOP TUNING OUT OF ORDER

7529 RECEIVER FAULT

7530 TX OUTPUT POWER LEVEL DECREASED

7531 TX OUTPUT POWER LOST

7532 TRANSMITTER OUT OF CONTROL

7533 TX ANTENNA OR COMBINER CONNECTIONFAULTY

7535 RECEIVING FAULT IN BASEBAND MODULE

7536 FAILURE IN MAIN RECEIVING PATH OFBASEBAND MODULE

7537 FAILURE IN DIVERSITY RECEIVING PATH OFBASEBAND MODULE

7538 SIGNALLING ERROR IN ABIS INTERFACE

7539 SIGNALLING ERROR IN DBUS

7540 AIR INTERFACE DUMB

7541 PART OF AIR TIME SLOTS DUMB

7542 LAPD LINK OFF

7543 FRAME NUMBER DISCREPANCY

7544 CONFIGURATION FAILURE IN ABIS AND DBUSINTERFACE OF TRX

7545 SAVING OPERATION IN TRX SUCCEEDED

7546 SAVING OPERATION IN TRX FAILED

7547 INTERNAL SIGNALLING FAILURE

7548 DATA TRANSFER FAILURE ON TRANSCODERCONNECTION

14 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 15: Alarm

7549 INTERNAL DATA TRANSFER FAILURE

7550 FAILURE IN LOOP TEST OF SITE TEST MONITOR

7551 FAILURE IN RX-ANTENNA SUPERVISION TESTLOOP

7552 FAULT IN TRX NON-VOLATILE MEMORY

7553 MEMORY FAULT IN DBUS INTERFACE OF TRX

7560 E-CELL ADJUSTMENT FAILED

7590 ANTENNA PERFORMANCE DEGRADED

7591 ANTENNA FAULTY

7592 LOW NOISE AMPLIFIERS OUT OF ORDER

7593 FAULT IN LOW NOISE AMPLIFIER

7594 ANTENNA TESTLOOP FAILURE

7600 BCF FAULTY

7601 BCF OPERATION DEGRADED

7602 BCF NOTIFICATION

7603 BTS FAULTY

7604 BTS OPERATION DEGRADED

7605 BTS NOTIFICATION

7606 TRX FAULTY

7607 TRX OPERATION DEGRADED

7608 TRX NOTIFICATION

7609 TRE FAULTY

7612 SITE POWERING FAULTY

7613 SITE POWERING OPERATION DEGRADED

7614 SITE POWERING NOTIFICATION

7615 RTS IS IN TEST USE

7616 OSCILLATOR ADJUSTING TEMPORARILYINTERRUPTED

7617 SEVERAL CALLS DROPPED DUE TO PROBLEMWITH TRANSCODER

7620 INCOMING POWER LOST

7621 INTOLERABLE CONDITIONS ON SITE

7622 CABINET OPEN

7700 BTS OMU INITIALIZATION

7701 BCF INITIALIZATION

7702 BCF INITIALIZATION DUE TO BSS RESET

7704 PCM FAILURE

7705 LAPD FAILURE

7706 BTS O&M LINK FAILURE

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 15 (1095)

List of Alarms

Page 16: Alarm

7708 TRX RESTARTED

7709 UNDEFINED BTS ALARM NUMBER

7710 OBJECT ADMINISTRATIVE STATE CHANGED

7711 WORKING FULL RATE TCH RATIO BELOWTHRESHOLD

7712 WORKING SDCCH CHANNEL RATIO BELOWTHRESHOLD

7713 SOFTWARE BACKGROUND DOWNLOAD TO BCFFAILS

7714 BCF REMOTE MMI CONNECTION IS IN USE

7715 CONTINUOUS RESTARTS OF BCF/TRX

7716 ACTIVE BCF HW DATABASE DIFFERENCE

7717 WORKING HALF RATE TCH RATIO BELOWTHRESHOLD

7718 TRX NOT HOPPING DUE TO FAULT

7719 TRX INITIALISATION

7720 SDCCH ACTIVATION FAILURE

7721 COMMUNICATION FAILURE WITH BCF

7722 ERROR IN BSS RADIO NETWORK DATABASEUPDATE

7723 FAILURE IN SENDING SYSTEM INFORMATIONTO BTS SITE

7724 CONFLICT BETWEEN BSS RADIO NETWORKDATABASE AND CALL CONTROL

7725 TRAFFIC CHANNEL ACTIVATION FAILURE

7726 CELL IN MINIMUM CONFIGURATION

7727 TRAFFIC CHANNEL NUMBER DECREASED

7728 OBJECT OUT OF USE BECAUSE OF ERROR INBTS INTERNAL DIAGNOSTICS

7729 RADIO NETWORK RECOVERY FAILED

7730 CONFIGURATION OF BCF FAILED

7731 BCF SW PACKAGE MAY BE DIFFERENT ASDEFINED AS A DEFAULT IN BSC

7732 TEMPORARY ORIGINATING STM TEST CALLFAILURE

7733 COMMUNICATION FAILURE WITH TRX

7734 BCCH IS NOT AT PREFERRED BCCH TRX

7735 TRX TEST FAILED

7736 ABIS LOOP TEST FAILED

7737 INCONSISTENT DATA IN RADIO RESOURCEMANAGEMENT STATE FILES

16 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 17: Alarm

7738 BTS WITH NO TRANSACTIONS

7739 ORIGINATING STM TEST CALL FAILED

7740 BEATING BTS ALARM

7741 MEAN HOLDING TIME ABOVE DEFINEDTHRESHOLD

7742 BCF MAINTENANCE MODE

7743 MEAN HOLDING TIME BELOW DEFINEDTHRESHOLD

7744 EXCESSIVE TCH INTERFERENCE

7745 CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD

7746 CH CONGESTION IN CELL ABOVE DEFINEDTHRESHOLD

7747 RX SENSITIVITY MEASUREMENT TEST FAILED

7748 BCF BACKGROUND DATA SWAP TIMEREXPIRED

7749 E-RACH MISSING

7751 TEST TIME SLOT RELEASE FAILED

7752 TRX TEST FAILED

7753 TRX LOOP TEST FAILED

7754 ANTENNA LOOP TEST FAILED

7755 PHASE 1 BTS IS TRIED TO BE DEFINED AS DUALBAND BTS

7756 BLOCKED BECAUSE WAITING FOR ABISAUTOCONFIGURATION

7757 ABIS AUTOCONFIGURATION FAILED

7758 ABIS AUTOCONFIGURATION COMPLETED

7759 BTS SYNCHRONIZATION SETTING FAILED

7763 ACCESS CLASS BARRED

7764 DFCA USE PREVENTED DUE ANOTHER BSCUNCONTROLLED INTERFERENCE

7765 DFCA NEIGHBOUR CELL CONFLICT

7767 BCCH MISSING

7768 INCONSISTENT DATA IN DFCA RADIORESOURCE STATE FILES

7769 FAILURE IN UPDATING CELL SPECIFICPARAMETERS TO PCU

7770 AUTOMATIC UNLOCK OF BCF FAILED

7787 SYNCHRONISATION IS MISSING

7789 NO (E)GPRS TRANSACTIONS IN BTS

7801 MMI CONNECTED TO BASE STATION

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 17 (1095)

List of Alarms

Page 18: Alarm

7802 LOCALLY LOADED SW SAVED TO BASE STATION

7803 LOCAL CONFIGURATION SAVED TO BASESTATION

7804 UNIT TEMPERATURE INCREASED

7805 UNIT TEMPERATURE HIGH

7806 UNIT TEMPERATURE DANGEROUSLY HIGH

7807 FAULT IN MMI-INTERFACE OF BASE STATION

7808 FAULT IN Q1-INTERFACE OF BCF

7809 FAULT IN DBUS DETECTED BY BCF

7810 FAULT IN WATCH-DOG OF BCF

7811 FAULT IN EXTERNAL DIGITAL ALARM LINE

7812 FAULT IN BCF NON-VOLATILE MEMORY

7813 MEMORY FAULT IN DBUS INTERFACE OF BCF

7815 FAULT IN BCF NON-VOLATILE MEMORYPROGRAMMING VOLTAGE

7816 NON-VOLATILE MEMORY PROGRAMMINGABORTED IN BCF

7817 MASTER CLOCK OVEN OSCILLATOR WARMINGUP

7818 FAULT IN MASTER CLOCK OVEN OSCILLATOR

7820 2.048 MHZ PCM CLOCK IS MISSING

7821 FRAME CLOCK IS MISSING FROM MASTERCLOCK GENERATOR

7822 TIMESLOT CLOCK IS MISSING FROM MASTERCLOCK GENERATOR

7823 2 MHZ REFERENCE CLOCK IS MISSING FROMMASTER CLOCK GENERATOR

7824 13 MHZ SOURCE CLOCK MISSING FROM DIV.MASTER CLOCK OSCILLATOR

7825 13 MHZ SOURCE CLOCK MISSING FROMMASTER CLOCK OSCILLATOR

7826 13 MHZ CLOCK MISSING FROM MASTER CLOCKGENERATOR

7828 ERROR IN FRAME NUMBER IN MASTER CLOCKGENERATOR

7829 FAULT IN ABIS AND DBUS INTERFACE OF BCF

7830 FREQUENCY HOPPING OUT OF ORDER

7831 ERROR IN BOOT SOFTWARE DOWNLOADING INFREQUENCY HOPPING

7832 TEST FAILED IN INTERNAL MEMORY OFFREQUENCY HOPPING

18 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 19: Alarm

7833 FAILURE IN FREQUENCY HOPPING BUS

7834 FREQUENCY HOPPING PROCESSOR RESET

7835 DATA ERROR IN FREQUENCY HOPPING BUS

7836 TEST FAILED IN EXTERNAL MEMORY OFFREQUENCY HOPPING

7838 13 MHZ SOURCE CLOCK ADJUSTMENTREACHING THE LIMIT VALUE

7839 DIFFERENCE IN FREQUENCIES BETWEEN PCMAND BTS MASTER CLOCK

7840 SW DOWNLOAD TO UNIT FAILED

7841 INITIALIZATION OF THE UNIT FAILED

7842 NO BCCH TRANSMISSION ACTIVATED

7850 EXTERNAL FRAME CLOCK IS MISSING

7851 EXTERNAL FRAME NUMBER IS MISSING

7852 BTS HEATER FAILURE

7853 TEMPERATURE DANGEROUSLY HIGH

7854 TEMPERATURE INCREASED

7860 NO CONNECTION TO TRANSMISSION UNIT

7861 SERVICE TERMINAL CONNECTED TO ABISTRANSMISSION EQUIPMENT

7868 FAULT IN MAIN RX BRANCH OF REDUNDANTTRX SWITCH

7870 CABINET DOOR OPEN

7872 CABINET TEMPERATURE TOO HIGH

7873 CABINET TEMPERATURE TOO LOW

7874 TEMPERATURE CONTROLLING DEVICE FAULTY

7875 EXTERNAL BTS SYNCHRONISATION SOURCE ISMISSING

7876 LMU: EXTERNAL SYNCHRONISATION SIGNALSDISABLED

7878 SERIAL LINK FAULTY IN FREQ. HOPPINGPROCESSOR

7879 SW DOWNLOADING TO FREQ.HOPPINGPROCESSOR FAILED

7880 CONFIGURATION FAILURE IN FREQ. HOPPINGPROCESSOR

7882 SMOKE DETECTED IN CABINET

7890 FAULT IN COOLING FAN

7891 SITE TEST MONITOR OUT OF ORDER

7892 SITE TEST MONITOR CAN NOT FIND BCCHCARRIER

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 19 (1095)

List of Alarms

Page 20: Alarm

7893 FAULT IN DBUS INTERFACE OF SITE TESTMONITOR

7894 FAULT IN INTERNAL BUS OF SITE TESTMONITOR

7895 FAULT IN MEMORY OF SITE TEST MONITOR

7896 FAULT IN DBUS INTERFACE OF SITE TESTMONITOR

7897 FAULT IN NON-VOLATILE MEMORY OF SITETEST MONITOR

7898 SIM-CARD OF SITE TEST MONITOR DOES NOTWORK

7899 MEMORY FAULT IN DBUS INTERFACE OF SITETEST MONITOR

7900 NO CONNECTION TO TRX

7905 SITE TEST MONITOR NOT OPERATING

7906 FAILURE IN RF COUPLING OF SITE TESTMONITOR

7907 +7 V POWER SUPPLY FAULTY IN SITE TESTMONITOR UNIT

7908 +12 V POWER SUPPLY FAULTY IN SITE TESTMONITOR UNIT

7909 -12 V POWER SUPPLY FAULTY IN SITE TESTMONITOR UNIT

7937 UNIT TEMPERATURE DANGEROUSLY HIGH

7939 FORWARD POWER TOO LOW AT TX ANTENNA

7941 TX ANTENNA PERFORMANCE DEGRADED

7942 TX ANTENNA FAULTY

7943 FAULT IN MAIN BRANCH LNA OF ANTENNAFILTER UNIT

7944 MAIN BRANCH LNA OUT OF ORDER IN ANTENNAFILTER UNIT

7945 FAULT IN DIVERSITY BRANCH LNA OF ANTENNAFILTER UNIT

7946 DIVERSITY BRANCH LNA OUT OF ORDER INANTENNA FILTER UNIT

7947 MAIN BRANCH MAST HEAD PREAMPLIFIER OUTOF ORDER

7948 DIVERSITY BRANCH MAST HEADPREAMPLIFIER OUT OF ORDER

7949 DIFFERENCE IN RX LEVELS OF MAIN ANDDIVERSITY ANTENNA / TRX

7950 NO CONNECTION TO REMOTE TUNE COMBINER

20 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 21: Alarm

7952 TUNING FAILED IN CAVITY OF REMOTE TUNECOMBINER

7953 TX ANTENNA PERFORMANCE DEGRADED

7954 TX ANTENNA FAULTY

7955 SYNTHESIZER OUT OF ORDER IN REMOTETUNE COMBINER

7956 CONTROLLER OUT OF ORDER IN REMOTETUNE COMBINER

7957 FAULT IN +5V POWER SUPPLY OF REMOTETUNE COMBINER

7958 FAULT IN +12V POWER SUPPLY OF REMOTETUNE COMBINER

7959 FAULT IN -12V POWER SUPPLY OF REMOTETUNE COMBINER

7960 FAULT IN +26V POWER SUPPLY OF REMOTETUNE COMBINER

7961 TUNING CARRIER NOT PRESENT IN REMOTETUNE COMBINER

7962 PERIODICAL CAVITY TEST FAILED, CAVITY NOTAVAILABLE

7963 CAVITY RESET FAILED, CAVITY NOT AVAILABLE

7964 FAULT IN NON-VOLATILE MEMORY OF REMOTETUNE COMBINER

7965 MEMORY FAULT IN DBUS INTERFACE OFREMOTE TUNE COMBINER

7966 FAULT IN DBUS INTERFACE OF REMOTE TUNECOMBINER

7967 FAULT IN MEMORY OF REMOTE TUNECOMBINER

7968 CONTROLLER FAULTY IN REMOTE TUNECOMBINER

7969 FORWARD POWER TOO LOW AT TX ANTENNA

7970 FAULT IN MAIN BRANCH LNA OF RECEIVERMULTICOUPLER

7971 FAULT IN DIVERSITY BRANCH LNA OFRECEIVER MULTICOUPLER

7972 MAIN BRANCH LNA OUT OF ORDER INRECEIVER MULTICOUPLER

7973 DIVERSITY BRANCH LNA OUT OF ORDER INRECEIVER MULTICOUPLER

7974 BOOSTER TEMPERATURE TOO HIGH

7975 BOOSTER TX CONNECTION FAULTY

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 21 (1095)

List of Alarms

Page 22: Alarm

7976 BOOSTER GAIN LEVEL TOO LOW

7980 NO CONNECTION TO SITE TEST MONITOR UNIT

7981 NO CONNECTION TO RADIO RELAY

7990 MAINS BREAKDOWN WITHOUT BATTERY BACK-UP

7991 POWER SUPPLY FAULT

7995 MAINS BREAKDOWN WITH BATTERY BACK-UP

7996 BACK-UP BATTERY VOLTAGE LOW

7997 BATTERY CHARGER FAILURE

7998 BBUE INVERTER OVERLOAD

7999 BATTERY FAILURE

BTS ALARM PARAMETERS

NUMBER CLASS RECOVERY PRINTING OMC UPD. IDL CDL STATE

------ ----- -------- -------- -------- --- --- ---------

7001 ** ON OFF ON 10 10 UNBLOCKED

7002 ** ON OFF ON 10 10 UNBLOCKED

7003 * ON OFF ON 10 10 UNBLOCKED

7004 * ON OFF ON 10 10 UNBLOCKED

7005 ** ON OFF ON 10 10 UNBLOCKED

7006 ** ON OFF ON 10 10 UNBLOCKED

7007 ** ON OFF ON 10 10 UNBLOCKED

7008 ** ON OFF ON 10 10 UNBLOCKED

7009 ** ON OFF ON 10 10 UNBLOCKED

7010 * ON OFF ON 10 10 UNBLOCKED

7011 * ON OFF ON 10 10 UNBLOCKED

7012 ** ON OFF ON 10 10 UNBLOCKED

7013 ** ON OFF ON 10 10 UNBLOCKED

7014 ** ON OFF ON 10 10 UNBLOCKED

7016 *** ON OFF ON 10 10 UNBLOCKED

7017 *** ON OFF ON 10 10 UNBLOCKED

7020 * ON OFF ON 10 10 UNBLOCKED

7021 * ON OFF ON 10 10 UNBLOCKED

7022 *** ON OFF ON 10 10 UNBLOCKED

7023 * ON OFF ON 10 10 UNBLOCKED

7024 *** ON OFF ON 10 10 UNBLOCKED

7030 * ON OFF ON 10 10 UNBLOCKED

7031 * ON OFF ON 10 10 UNBLOCKED

7032 * ON OFF ON 10 10 UNBLOCKED

7033 * ON OFF ON 10 10 UNBLOCKED

7034 * ON OFF ON 10 10 UNBLOCKED

7035 * ON OFF ON 10 10 UNBLOCKED

7036 * ON OFF ON 10 10 UNBLOCKED

7037 * ON OFF ON 10 10 UNBLOCKED

7038 * ON OFF ON 10 10 UNBLOCKED

7039 * ON OFF ON 10 10 UNBLOCKED

7040 * ON OFF ON 10 10 UNBLOCKED

7041 * ON OFF ON 10 10 UNBLOCKED

7042 * ON OFF ON 10 10 UNBLOCKED

7043 * ON OFF ON 10 10 UNBLOCKED

22 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 23: Alarm

7044 * ON OFF ON 10 10 UNBLOCKED

7045 * ON OFF ON 10 10 UNBLOCKED

7050 ON OFF ON 10 10 UNBLOCKED

7051 ON OFF ON 10 10 UNBLOCKED

7052 ON OFF ON 10 10 UNBLOCKED

7053 ON OFF ON 10 10 UNBLOCKED

7054 ** ON OFF ON 10 10 UNBLOCKED

7060 ** ON OFF ON 10 10 UNBLOCKED

7061 ** ON OFF ON 10 10 UNBLOCKED

7062 ** ON OFF ON 10 10 UNBLOCKED

7063 ** ON OFF ON 10 10 UNBLOCKED

7064 ** ON OFF ON 10 10 UNBLOCKED

7065 ** ON OFF ON 10 10 UNBLOCKED

7066 ** ON OFF ON 10 10 UNBLOCKED

7067 *** ON OFF ON 10 10 UNBLOCKED

7068 ** ON OFF ON 10 10 UNBLOCKED

7069 ** ON OFF ON 10 10 UNBLOCKED

7100 * ON OFF ON 10 10 UNBLOCKED

7101 * ON OFF ON 10 10 UNBLOCKED

7102 * ON OFF ON 10 10 UNBLOCKED

7103 * ON OFF ON 10 10 UNBLOCKED

7104 * ON OFF ON 10 10 UNBLOCKED

7105 * ON OFF ON 10 10 UNBLOCKED

7106 * ON OFF ON 10 10 UNBLOCKED

7107 * ON OFF ON 10 10 UNBLOCKED

7108 * ON OFF ON 10 10 UNBLOCKED

7109 * ON OFF ON 10 10 UNBLOCKED

7110 * ON OFF ON 10 10 UNBLOCKED

7120 * ON OFF ON 10 10 UNBLOCKED

7121 * ON OFF ON 10 10 UNBLOCKED

7122 ** ON OFF ON 10 10 UNBLOCKED

7123 * ON OFF ON 10 10 UNBLOCKED

7124 ** ON OFF ON 10 10 UNBLOCKED

7125 * ON OFF ON 10 10 UNBLOCKED

7126 ** ON OFF ON 10 10 UNBLOCKED

7127 * ON OFF ON 10 10 UNBLOCKED

7128 ** ON OFF ON 10 10 UNBLOCKED

7129 * ON OFF ON 10 10 UNBLOCKED

7130 * ON OFF ON 10 10 UNBLOCKED

7131 ** ON OFF ON 10 10 UNBLOCKED

7132 ** ON OFF ON 10 10 UNBLOCKED

7133 * ON OFF ON 10 10 UNBLOCKED

7134 * ON OFF ON 10 10 UNBLOCKED

7135 * ON OFF ON 10 10 UNBLOCKED

7136 * ON OFF ON 10 10 UNBLOCKED

7137 * ON OFF ON 10 10 UNBLOCKED

7138 * ON OFF ON 10 10 UNBLOCKED

7139 ** ON OFF ON 10 10 UNBLOCKED

7140 ** ON OFF ON 10 10 UNBLOCKED

7141 ** ON OFF ON 10 10 UNBLOCKED

7150 ** ON OFF ON 10 10 UNBLOCKED

7151 ** ON OFF ON 10 10 UNBLOCKED

7152 * ON OFF ON 10 10 UNBLOCKED

7153 * ON OFF ON 10 10 UNBLOCKED

7154 * ON OFF ON 10 10 UNBLOCKED

7156 ** ON OFF ON 10 10 UNBLOCKED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 23 (1095)

List of Alarms

Page 24: Alarm

7157 ** ON OFF ON 10 10 UNBLOCKED

7158 * ON OFF ON 10 10 UNBLOCKED

7159 * ON OFF ON 10 10 UNBLOCKED

7160 * ON OFF ON 10 10 UNBLOCKED

7161 * ON OFF ON 10 10 UNBLOCKED

7162 * ON OFF ON 10 10 UNBLOCKED

7163 ** ON OFF ON 10 10 UNBLOCKED

7164 *** ON OFF ON 10 10 UNBLOCKED

7170 ** ON OFF ON 10 10 UNBLOCKED

7171 ** ON OFF ON 10 10 UNBLOCKED

7172 ** ON OFF ON 10 10 UNBLOCKED

7173 ** ON OFF ON 10 10 UNBLOCKED

7174 *** ON OFF ON 10 10 UNBLOCKED

7175 ** ON OFF ON 10 10 UNBLOCKED

7176 ** ON OFF ON 10 10 UNBLOCKED

7177 ** ON OFF ON 10 10 UNBLOCKED

7190 * ON OFF ON 10 10 UNBLOCKED

7191 * ON OFF ON 10 10 UNBLOCKED

7192 * ON OFF ON 10 10 UNBLOCKED

7193 ** ON OFF ON 10 10 UNBLOCKED

7194 * ON OFF ON 10 10 UNBLOCKED

7195 ** ON OFF ON 10 10 UNBLOCKED

7196 * ON OFF ON 10 10 UNBLOCKED

7197 ** ON OFF ON 10 10 UNBLOCKED

7198 * ON OFF ON 10 10 UNBLOCKED

7199 * ON OFF ON 10 10 UNBLOCKED

7200 * ON OFF ON 10 10 UNBLOCKED

7201 * ON OFF ON 10 10 UNBLOCKED

7202 * ON OFF ON 10 10 UNBLOCKED

7203 *** ON OFF ON 10 10 UNBLOCKED

7204 *** ON OFF ON 10 10 UNBLOCKED

7205 ON OFF ON 10 10 UNBLOCKED

7206 ON OFF ON 10 10 UNBLOCKED

7207 ON OFF ON 10 10 UNBLOCKED

7208 * ON OFF ON 10 10 UNBLOCKED

7209 *** ON OFF ON 10 10 UNBLOCKED

7210 *** ON OFF ON 0 0 UNBLOCKED

7211 *** ON OFF ON 10 10 UNBLOCKED

7212 ON OFF ON 10 10 UNBLOCKED

7214 ON OFF ON 10 10 UNBLOCKED

7215 ON OFF ON 10 10 UNBLOCKED

7216 ON OFF ON 10 10 UNBLOCKED

7217 ON OFF ON 10 10 UNBLOCKED

7218 ON OFF ON 10 10 UNBLOCKED

7220 * ON OFF ON 0 0 UNBLOCKED

7221 * ON OFF ON 10 10 UNBLOCKED

7222 ** ON OFF ON 10 10 UNBLOCKED

7223 * ON OFF ON 10 10 UNBLOCKED

7224 * ON OFF ON 10 10 UNBLOCKED

7225 ** ON OFF ON 10 10 UNBLOCKED

7226 ** ON OFF ON 10 10 UNBLOCKED

7251 * ON OFF ON 10 10 UNBLOCKED

7252 * ON OFF ON 10 10 UNBLOCKED

7253 * ON OFF ON 10 10 UNBLOCKED

7254 * ON OFF ON 10 10 UNBLOCKED

7255 ** ON OFF ON 10 10 UNBLOCKED

24 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 25: Alarm

7256 ** ON OFF ON 10 10 UNBLOCKED

7257 ** ON OFF ON 10 10 UNBLOCKED

7258 ** ON OFF ON 10 10 UNBLOCKED

7259 ** ON OFF ON 10 10 UNBLOCKED

7260 ** ON OFF ON 10 10 UNBLOCKED

7261 ** ON OFF ON 10 10 UNBLOCKED

7262 ** ON OFF ON 10 10 UNBLOCKED

7263 ** ON OFF ON 10 10 UNBLOCKED

7264 ** ON OFF ON 10 10 UNBLOCKED

7265 * ON OFF ON 10 10 UNBLOCKED

7266 ** ON OFF ON 10 10 UNBLOCKED

7267 ** ON OFF ON 10 10 UNBLOCKED

7268 ** ON OFF ON 10 10 UNBLOCKED

7269 ** ON OFF ON 10 10 UNBLOCKED

7270 * ON OFF ON 10 10 UNBLOCKED

7271 ** ON OFF ON 10 10 UNBLOCKED

7272 * ON OFF ON 10 10 UNBLOCKED

7273 ** ON OFF ON 10 10 UNBLOCKED

7274 ** ON OFF ON 10 10 UNBLOCKED

7275 * ON OFF ON 10 10 UNBLOCKED

7276 ** ON OFF ON 10 10 UNBLOCKED

7277 ** ON OFF ON 10 10 UNBLOCKED

7278 ** ON OFF ON 10 10 UNBLOCKED

7279 ** ON OFF ON 10 10 UNBLOCKED

7280 ** ON OFF ON 10 10 UNBLOCKED

7281 ** ON OFF ON 10 10 UNBLOCKED

7282 * ON OFF ON 10 10 UNBLOCKED

7283 * ON OFF ON 10 10 UNBLOCKED

7284 ** ON OFF ON 10 10 UNBLOCKED

7285 ** ON OFF ON 10 10 UNBLOCKED

7286 * ON OFF ON 10 10 UNBLOCKED

7287 ** ON OFF ON 10 10 UNBLOCKED

7288 * ON OFF ON 10 10 UNBLOCKED

7291 * ON OFF ON 10 10 UNBLOCKED

7292 * ON OFF ON 10 10 UNBLOCKED

7293 * ON OFF ON 10 10 UNBLOCKED

7294 * ON OFF ON 10 10 UNBLOCKED

7301 ** ON OFF ON 10 10 UNBLOCKED

7302 ** ON OFF ON 10 10 UNBLOCKED

7303 ** ON OFF ON 10 10 UNBLOCKED

7304 ** ON OFF ON 10 10 UNBLOCKED

7305 * ON OFF ON 10 10 UNBLOCKED

7306 ** ON OFF ON 10 10 UNBLOCKED

7307 * ON OFF ON 10 10 UNBLOCKED

7308 ** ON OFF ON 10 10 UNBLOCKED

7309 * ON OFF ON 10 10 UNBLOCKED

7310 * ON OFF ON 10 10 UNBLOCKED

7311 ** ON OFF ON 10 10 UNBLOCKED

7312 ** ON OFF ON 10 10 UNBLOCKED

7313 * ON OFF ON 10 10 UNBLOCKED

7314 *** ON OFF ON 10 10 UNBLOCKED

7315 *** ON OFF ON 10 10 UNBLOCKED

7316 ** ON OFF ON 10 10 UNBLOCKED

7317 ** ON OFF ON 10 10 UNBLOCKED

7318 * ON OFF ON 10 10 UNBLOCKED

7319 *** ON OFF ON 10 10 UNBLOCKED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 25 (1095)

List of Alarms

Page 26: Alarm

7320 *** ON OFF ON 10 10 UNBLOCKED

7321 ** ON OFF ON 10 10 UNBLOCKED

7322 ** ON OFF ON 10 10 UNBLOCKED

7323 ** ON OFF ON 10 10 UNBLOCKED

7324 *** ON OFF ON 10 10 UNBLOCKED

7325 ON OFF ON 10 10 UNBLOCKED

7326 ** ON OFF ON 10 10 UNBLOCKED

7327 ** ON OFF ON 10 10 UNBLOCKED

7328 *** ON OFF ON 10 10 UNBLOCKED

7329 *** ON OFF ON 10 10 UNBLOCKED

7330 ** ON OFF ON 10 10 UNBLOCKED

7331 ** ON OFF ON 10 10 UNBLOCKED

7332 * ON OFF ON 10 10 UNBLOCKED

7401 ON OFF ON 10 10 UNBLOCKED

7402 ON OFF ON 10 10 UNBLOCKED

7403 ON OFF ON 10 10 UNBLOCKED

7404 ON OFF ON 10 10 UNBLOCKED

7405 ON OFF ON 10 10 UNBLOCKED

7406 ON OFF ON 10 10 UNBLOCKED

7407 ON OFF ON 10 10 UNBLOCKED

7408 ON OFF ON 10 10 UNBLOCKED

7409 ON OFF ON 10 10 UNBLOCKED

7410 ON OFF ON 10 10 UNBLOCKED

7411 ON OFF ON 10 10 UNBLOCKED

7412 ON OFF ON 10 10 UNBLOCKED

7413 ON OFF ON 10 10 UNBLOCKED

7414 ON OFF ON 10 10 UNBLOCKED

7415 ON OFF ON 10 10 UNBLOCKED

7416 ON OFF ON 10 10 UNBLOCKED

7417 ON OFF ON 10 10 UNBLOCKED

7418 ON OFF ON 10 10 UNBLOCKED

7419 ON OFF ON 10 10 UNBLOCKED

7420 ON OFF ON 10 10 UNBLOCKED

7421 ON OFF ON 10 10 UNBLOCKED

7422 ON OFF ON 10 10 UNBLOCKED

7423 ON OFF ON 10 10 UNBLOCKED

7424 ON OFF ON 10 10 UNBLOCKED

7425 ON OFF ON 10 10 UNBLOCKED

7426 ON OFF ON 10 10 UNBLOCKED

7427 ON OFF ON 10 10 UNBLOCKED

7428 ON OFF ON 10 10 UNBLOCKED

7429 ON OFF ON 10 10 UNBLOCKED

7430 ON OFF ON 10 10 UNBLOCKED

7500 * ON OFF ON 10 10 UNBLOCKED

7501 * ON OFF ON 10 10 UNBLOCKED

7502 * ON OFF ON 10 10 UNBLOCKED

7503 ** ON OFF ON 10 10 UNBLOCKED

7504 ** ON OFF ON 10 10 UNBLOCKED

7505 ** ON OFF ON 10 10 UNBLOCKED

7506 ** ON OFF ON 10 10 UNBLOCKED

7507 ** ON OFF ON 10 10 UNBLOCKED

7508 ** ON OFF ON 10 10 UNBLOCKED

7509 ** ON OFF ON 10 10 UNBLOCKED

7510 ** ON OFF ON 10 10 UNBLOCKED

7511 ** ON OFF ON 10 10 UNBLOCKED

7512 ** ON OFF ON 10 10 UNBLOCKED

26 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 27: Alarm

7513 ** ON OFF ON 10 10 UNBLOCKED

7514 ** ON OFF ON 10 10 UNBLOCKED

7515 ** ON OFF ON 10 10 UNBLOCKED

7516 ** ON OFF ON 10 10 UNBLOCKED

7517 ** ON OFF ON 10 10 UNBLOCKED

7518 ** ON OFF ON 10 10 UNBLOCKED

7519 ** ON OFF ON 10 10 UNBLOCKED

7520 ** ON OFF ON 10 10 UNBLOCKED

7521 * ON OFF ON 10 10 UNBLOCKED

7522 ** ON OFF ON 10 10 UNBLOCKED

7523 ** ON OFF ON 10 10 UNBLOCKED

7524 ** ON OFF ON 10 10 UNBLOCKED

7525 ** ON OFF ON 10 10 UNBLOCKED

7526 ** ON OFF ON 10 10 UNBLOCKED

7527 ** ON OFF ON 10 10 UNBLOCKED

7528 ** ON OFF ON 10 10 UNBLOCKED

7529 ** ON OFF ON 10 10 UNBLOCKED

7530 ** ON OFF ON 10 10 UNBLOCKED

7531 ** ON OFF ON 10 10 UNBLOCKED

7532 ** ON OFF ON 10 10 UNBLOCKED

7533 ** ON OFF ON 10 10 UNBLOCKED

7535 ** ON OFF ON 10 10 UNBLOCKED

7536 ** ON OFF ON 10 10 UNBLOCKED

7537 ** ON OFF ON 10 10 UNBLOCKED

7538 ** ON OFF ON 10 10 UNBLOCKED

7539 ** ON OFF ON 10 10 UNBLOCKED

7540 ** ON OFF ON 10 10 UNBLOCKED

7541 ** ON OFF ON 10 10 UNBLOCKED

7542 * ON OFF ON 10 10 UNBLOCKED

7543 * ON OFF ON 10 10 UNBLOCKED

7544 ** ON OFF ON 10 10 UNBLOCKED

7545 ON OFF ON 10 10 UNBLOCKED

7546 ** ON OFF ON 10 10 UNBLOCKED

7547 ** ON OFF ON 10 10 UNBLOCKED

7548 ON OFF ON 10 10 UNBLOCKED

7549 ** ON OFF ON 10 10 UNBLOCKED

7550 ** ON OFF ON 10 10 UNBLOCKED

7551 ** ON OFF ON 10 10 UNBLOCKED

7552 ** ON OFF ON 10 10 UNBLOCKED

7553 ** ON OFF ON 10 10 UNBLOCKED

7560 ** ON OFF ON 10 10 UNBLOCKED

7590 ** ON OFF ON 10 10 UNBLOCKED

7591 ** ON OFF ON 10 10 UNBLOCKED

7592 *** ON OFF ON 10 10 UNBLOCKED

7593 ** ON OFF ON 10 10 UNBLOCKED

7594 ** ON OFF ON 10 10 UNBLOCKED

7600 *** ON OFF ON 10 10 UNBLOCKED

7601 ** ON OFF ON 15 15 UNBLOCKED

7602 * ON OFF ON 10 10 UNBLOCKED

7603 *** ON OFF ON 10 10 UNBLOCKED

7604 ** ON OFF ON 15 60 UNBLOCKED

7605 * ON OFF ON 10 10 UNBLOCKED

7606 ** ON OFF ON 10 10 UNBLOCKED

7607 ** ON OFF ON 15 15 UNBLOCKED

7608 * ON OFF ON 10 10 UNBLOCKED

7609 *** ON OFF ON 10 10 UNBLOCKED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 27 (1095)

List of Alarms

Page 28: Alarm

7612 *** ON OFF ON 10 10 UNBLOCKED

7613 ** ON OFF ON 10 10 UNBLOCKED

7614 * ON OFF ON 10 10 UNBLOCKED

7615 * ON OFF ON 0 0 UNBLOCKED

7616 * ON OFF ON 10 10 UNBLOCKED

7617 ** ON OFF ON 10 10 UNBLOCKED

7620 * ON OFF ON 10 10 UNBLOCKED

7621 * ON OFF ON 10 10 UNBLOCKED

7622 * ON OFF ON 10 10 UNBLOCKED

7700 * ON OFF ON 0 0 UNBLOCKED

7701 * ON OFF ON 0 0 UNBLOCKED

7702 * ON OFF OFF 0 0 UNBLOCKED

7704 ** ON OFF ON 0 0 UNBLOCKED

7705 * ON OFF ON 0 0 UNBLOCKED

7706 ** OFF OFF ON 0 0 UNBLOCKED

7708 ON OFF ON 0 0 UNBLOCKED

7709 * ON OFF ON 10 10 UNBLOCKED

7710 OFF OFF ON 10 10 UNBLOCKED

7711 * OFF OFF ON 10 10 UNBLOCKED

7712 * OFF OFF ON 10 10 UNBLOCKED

7713 * OFF OFF ON 10 10 UNBLOCKED

7714 * ON OFF ON 10 10 UNBLOCKED

7715 * ON OFF ON 10 10 UNBLOCKED

7716 * ON OFF ON 10 10 UNBLOCKED

7717 * OFF OFF ON 10 10 UNBLOCKED

7718 * ON OFF ON 0 0 UNBLOCKED

7719 * ON OFF ON 0 0 UNBLOCKED

7720 OFF OFF ON 10 10 UNBLOCKED

7721 OFF OFF ON 10 10 UNBLOCKED

7722 *** OFF OFF ON 10 10 UNBLOCKED

7723 *** OFF OFF ON 10 10 UNBLOCKED

7724 *** OFF OFF ON 10 10 UNBLOCKED

7725 ** OFF OFF ON 10 10 UNBLOCKED

7726 *** OFF OFF ON 10 10 UNBLOCKED

7727 ** OFF OFF ON 10 10 UNBLOCKED

7728 * ON OFF ON 10 10 UNBLOCKED

7729 *** OFF OFF ON 10 10 UNBLOCKED

7730 ** OFF OFF ON 10 10 UNBLOCKED

7731 ** OFF OFF ON 10 10 UNBLOCKED

7732 OFF OFF ON 10 10 UNBLOCKED

7733 ** OFF OFF ON 10 10 UNBLOCKED

7734 ** OFF OFF ON 0 0 UNBLOCKED

7735 ** ON OFF ON 10 10 UNBLOCKED

7736 ** ON OFF ON 10 10 UNBLOCKED

7737 ** OFF OFF ON 10 10 UNBLOCKED

7738 ** OFF OFF ON 0 0 UNBLOCKED

7739 ** OFF OFF ON 10 10 UNBLOCKED

7740 * OFF OFF ON 0 0 UNBLOCKED

7741 ** OFF OFF ON 10 10 UNBLOCKED

7742 * ON OFF ON 0 0 UNBLOCKED

7743 ** OFF OFF ON 0 0 UNBLOCKED

7744 ** OFF OFF ON 10 10 UNBLOCKED

7745 ** OFF OFF ON 0 0 UNBLOCKED

7746 ** OFF OFF ON 10 10 UNBLOCKED

7747 ** OFF OFF ON 10 10 UNBLOCKED

7748 ** OFF OFF ON 10 10 UNBLOCKED

28 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 29: Alarm

7749 *** OFF OFF ON 10 10 UNBLOCKED

7751 ** OFF OFF ON 10 10 UNBLOCKED

7752 ** OFF OFF ON 10 10 BLOCKED

7753 ** OFF OFF ON 10 10 BLOCKED

7754 ** OFF OFF ON 10 10 BLOCKED

7755 ** OFF OFF ON 0 0 UNBLOCKED

7756 ** ON OFF ON 10 10 UNBLOCKED

7757 ** ON OFF ON 10 10 UNBLOCKED

7758 ON OFF ON 10 10 UNBLOCKED

7759 ** ON OFF ON 0 0 UNBLOCKED

7763 * ON OFF ON 0 0 UNBLOCKED

7764 ON OFF ON 10 10 UNBLOCKED

7765 * ON OFF ON 10 10 UNBLOCKED

7767 *** ON OFF ON 0 0 UNBLOCKED

7768 ** ON OFF ON 10 10 UNBLOCKED

7769 * ON OFF ON 0 0 UNBLOCKED

7770 * OFF OFF ON 0 0 UNBLOCKED

7787 ** ON OFF ON 10 10 UNBLOCKED

7788 OFF OFF ON 10 10 UNBLOCKED

7789 ** OFF OFF ON 10 10 UNBLOCKED

7801 * ON OFF ON 10 0 UNBLOCKED

7802 ON OFF ON 10 10 UNBLOCKED

7803 ON OFF ON 10 10 UNBLOCKED

7804 * ON OFF ON 10 10 UNBLOCKED

7805 * ON OFF ON 10 10 UNBLOCKED

7806 *** ON OFF ON 10 10 UNBLOCKED

7807 ** ON OFF ON 10 10 UNBLOCKED

7808 ** ON OFF ON 10 10 UNBLOCKED

7809 *** ON OFF ON 10 10 UNBLOCKED

7810 ** ON OFF ON 10 10 UNBLOCKED

7811 ** ON OFF ON 10 10 UNBLOCKED

7812 ** ON OFF ON 10 10 UNBLOCKED

7813 *** ON OFF ON 10 10 UNBLOCKED

7815 ON OFF ON 10 10 UNBLOCKED

7816 ON OFF ON 10 10 UNBLOCKED

7817 * ON OFF ON 10 10 UNBLOCKED

7818 *** ON OFF ON 10 10 UNBLOCKED

7820 * ON OFF ON 10 10 UNBLOCKED

7821 *** ON OFF ON 10 10 UNBLOCKED

7822 *** ON OFF ON 10 10 UNBLOCKED

7823 *** ON OFF ON 10 10 UNBLOCKED

7824 ** ON OFF ON 10 10 UNBLOCKED

7825 *** ON OFF ON 10 10 UNBLOCKED

7826 *** ON OFF ON 10 10 UNBLOCKED

7828 ** ON OFF ON 10 10 UNBLOCKED

7829 *** ON OFF ON 10 10 UNBLOCKED

7830 *** ON OFF ON 10 10 UNBLOCKED

7831 *** ON OFF ON 10 10 UNBLOCKED

7832 ** ON OFF ON 10 10 UNBLOCKED

7833 ** ON OFF ON 10 10 UNBLOCKED

7834 *** ON OFF ON 10 10 UNBLOCKED

7835 ** ON OFF ON 10 10 UNBLOCKED

7836 ** ON OFF ON 10 10 UNBLOCKED

7838 ** ON OFF ON 10 10 UNBLOCKED

7839 ** ON OFF ON 10 10 UNBLOCKED

7840 ** ON OFF ON 10 10 UNBLOCKED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 29 (1095)

List of Alarms

Page 30: Alarm

7841 ** ON OFF ON 10 10 UNBLOCKED

7842 *** ON OFF ON 10 10 UNBLOCKED

7850 ** ON OFF ON 10 10 UNBLOCKED

7851 ** ON OFF ON 10 10 UNBLOCKED

7852 ** ON OFF ON 10 10 UNBLOCKED

7853 ** ON OFF ON 10 10 UNBLOCKED

7854 * ON OFF ON 10 10 UNBLOCKED

7860 ** ON OFF ON 10 10 UNBLOCKED

7861 ** ON OFF ON 10 10 UNBLOCKED

7862 ON OFF ON 10 10 UNBLOCKED

7864 ** ON OFF ON 10 10 UNBLOCKED

7866 ** ON OFF ON 10 10 UNBLOCKED

7867 ** ON OFF ON 10 10 UNBLOCKED

7868 ** ON OFF ON 10 10 UNBLOCKED

7869 ** ON OFF ON 10 10 UNBLOCKED

7870 * ON OFF ON 10 10 UNBLOCKED

7871 ** ON OFF ON 10 10 UNBLOCKED

7872 *** ON OFF ON 10 10 UNBLOCKED

7873 *** ON OFF ON 10 10 UNBLOCKED

7874 ** ON OFF ON 10 10 UNBLOCKED

7875 *** ON OFF ON 10 10 UNBLOCKED

7876 ** ON OFF ON 10 10 UNBLOCKED

7878 ** ON OFF ON 10 10 UNBLOCKED

7879 *** ON OFF ON 10 10 UNBLOCKED

7880 *** ON OFF ON 10 10 UNBLOCKED

7882 *** ON OFF ON 10 10 UNBLOCKED

7890 * ON OFF ON 10 10 UNBLOCKED

7891 ** ON OFF ON 10 10 UNBLOCKED

7892 ** ON OFF ON 10 10 UNBLOCKED

7893 ** ON OFF ON 10 10 UNBLOCKED

7894 ** ON OFF ON 10 10 UNBLOCKED

7895 ** ON OFF ON 10 10 UNBLOCKED

7896 ** ON OFF ON 10 10 UNBLOCKED

7897 ** ON OFF ON 10 10 UNBLOCKED

7898 ** ON OFF ON 10 10 UNBLOCKED

7899 ** ON OFF ON 10 10 UNBLOCKED

7900 *** ON OFF ON 10 10 UNBLOCKED

7905 ** ON OFF ON 10 10 UNBLOCKED

7906 ** ON OFF ON 10 10 UNBLOCKED

7907 ** ON OFF ON 10 10 UNBLOCKED

7908 ** ON OFF ON 10 10 UNBLOCKED

7909 ** ON OFF ON 10 10 UNBLOCKED

7937 ** ON OFF ON 10 10 UNBLOCKED

7939 ** ON OFF ON 10 10 UNBLOCKED

7941 ** ON OFF ON 10 10 UNBLOCKED

7942 *** ON OFF ON 10 10 UNBLOCKED

7943 ** ON OFF ON 10 10 UNBLOCKED

7944 ** ON OFF ON 10 10 UNBLOCKED

7945 ** ON OFF ON 10 10 UNBLOCKED

7946 ** ON OFF ON 10 10 UNBLOCKED

7947 ** ON OFF ON 10 10 UNBLOCKED

7948 ** ON OFF ON 10 10 UNBLOCKED

7949 ** ON OFF ON 10 10 UNBLOCKED

7950 *** ON OFF ON 10 10 UNBLOCKED

7952 ** ON OFF ON 10 10 UNBLOCKED

7953 ** ON OFF ON 10 10 UNBLOCKED

30 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 31: Alarm

7954 *** ON OFF ON 10 10 UNBLOCKED

7955 *** ON OFF ON 10 10 UNBLOCKED

7956 *** ON OFF ON 10 10 UNBLOCKED

7957 *** ON OFF ON 10 10 UNBLOCKED

7958 *** ON OFF ON 10 10 UNBLOCKED

7959 *** ON OFF ON 10 10 UNBLOCKED

7960 *** ON OFF ON 10 10 UNBLOCKED

7961 ** ON OFF ON 10 10 UNBLOCKED

7962 * ON OFF ON 10 10 UNBLOCKED

7963 ** ON OFF ON 10 10 UNBLOCKED

7964 ** ON OFF ON 10 10 UNBLOCKED

7965 ** ON OFF ON 10 10 UNBLOCKED

7966 ** ON OFF ON 10 10 UNBLOCKED

7967 ** ON OFF ON 10 10 UNBLOCKED

7968 ** ON OFF ON 10 10 UNBLOCKED

7969 ** ON OFF ON 10 10 UNBLOCKED

7970 ** ON OFF ON 10 10 UNBLOCKED

7971 ** ON OFF ON 10 10 UNBLOCKED

7972 ** ON OFF ON 10 10 UNBLOCKED

7973 ** ON OFF ON 10 10 UNBLOCKED

7974 *** ON OFF ON 10 10 UNBLOCKED

7975 *** ON OFF ON 10 10 UNBLOCKED

7976 *** ON OFF ON 10 10 UNBLOCKED

7980 ** ON OFF ON 10 10 UNBLOCKED

7981 ** ON OFF ON 10 10 UNBLOCKED

7990 *** ON OFF ON 10 10 UNBLOCKED

7991 ** ON OFF ON 10 10 UNBLOCKED

7995 * ON OFF ON 10 10 UNBLOCKED

7996 *** ON OFF ON 10 10 UNBLOCKED

7997 ** ON OFF ON 10 10 UNBLOCKED

7998 *** ON OFF ON 10 10 UNBLOCKED

7999 ** ON OFF ON 10 10 UNBLOCKED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 31 (1095)

List of Alarms

Page 32: Alarm

32 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 33: Alarm

2 7001 TRX/FU: CHECKSUM ERROR INPRIMARY CU-FU LINK

Meaning

The frame unit (FU) has detected a data transfer check sum error in the

data which comes in from the carrier unit (CU). This alarm concerns the

redundant or diversity data link between the CU and the FU, which goes

via the redundant or diversity FQHU or DFHU.

This alarm has two categories: non-fatal (no effect on service) and

fatal (an effect on service). This alarm is fatal in the following cases:

- The number of the data transfer check sum errors in the primary link

exceeds the specified limit and there is a fatal alarm in the

diversity/redundant link.

- The number of the data transfer check sum errors in the primary

link exceeds the specified limit and the diversity/redundant link

is not equipped.

The fatality limits can be found in document Digital BTS FUC

Monitoring Interface, B61 S60005CE (C3_FHI_A_ERR).

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 33 (1095)

7001 TRX/FU: CHECKSUM ERROR IN PRIMARY CU-FU LINK

Page 34: Alarm

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1, and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the TXUA, the primary RXUA, the FUCx

and the DSPxs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

34 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 35: Alarm

3 7002 TRX/FU:CHECKSUM ERROR INREDUNDANT/DIVERSITY CU-FU LINK

Meaning

The frame unit (FU) has detected a data transfer check sum error in the

data which comes in from the carrier unit (CU). This alarm concerns the

redundant or diversity data link between the CU and the FU, which goes

via the redundant or diversity FQHU or DFHU.

This alarm has two categories: non-fatal (no effect on service) and

fatal (an effect on service). This alarm is fatal in the following cases:

- The number of the data transfer check sum errors in the redundant/

diversity link exceeds the specified limit and there is a fatal alarm

in the primary link.

- The number of the data transfer check sum errors in the redundant/

diversity link exceeds the specified limit and the primary link is

not equipped.

The fatality limits can be found in document Digital BTS FUC

Monitoring Interface, B61 S60005CE (C3_FHI_B_ERR).

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 35 (1095)

7002 TRX/FU:CHECKSUM ERROR IN REDUNDANT/DIVERSITYCU-FU LINK

Page 36: Alarm

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1, and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the TXUA, the diversity RXUA, the FUCx and

the DSPxs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

36 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 37: Alarm

4 7003 TRX/FU: NO DATA FROM FU TO CUMeaning

The carrier unit has detected that no data is coming in from the frame

unit (via the FQHU or the DFHU) to the carrier unit. The carrier unit

reports this alarm to the frame unit.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 37 (1095)

7003 TRX/FU: NO DATA FROM FU TO CU

Page 38: Alarm

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and

the FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

38 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 39: Alarm

5 7004 TRX/FU: FORMAT ERROR IN DATAFROM FU TO CU

Meaning

The carrier unit has detected a wrong number of bytes in the data

which is coming in from the frame unit (via the FQHU or the DFHU)

to the carrier unit. The carrier unit reports this alarm to the

frame unit.

This alarm does not affect the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 39 (1095)

7004 TRX/FU: FORMAT ERROR IN DATA FROM FU TO CU

Page 40: Alarm

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

40 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 41: Alarm

6 7005 TRX/FU: CHECKSUM ERROR INFU-CU LINK

Meaning

The carrier unit has detected a data transfer check sum error in the

data which comes in from the frame unit (via the FQHU or the DFHU) to

the carrier unit. The carrier unit reports this alarm to the frame unit.

This alarm has two categories: non-fatal (no effect on service) and

fatal (an effect on service). The fatality depends on the number of

alarms during an SACCH multiframe.

The fatality limits can be found in document Digital BTS FUC

Monitoring Interface, B61 S60005CE (C3_FHI_A_ERR).

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 41 (1095)

7005 TRX/FU: CHECKSUM ERROR IN FU-CU LINK

Page 42: Alarm

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the FQHUs and the

TXUA one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

42 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 43: Alarm

7 7006 TRX/FU: NO DATA FROM DSPx TOFUCx

Meaning

The frame unit controller board (FUCx) has detected that no data is

coming in from the digital signalling processing unit (DSPx) to the

FUCx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 43 (1095)

7006 TRX/FU: NO DATA FROM DSPx TO FUCx

Page 44: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the DSPxs and the FUCx one by one until

the fault situation is over.

Cancelling

This is a transient-type alarm. No cancelling.

44 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 45: Alarm

8 7007 TRX/FU: TOO MANY BYTES INDATA FROM DSPx TO FUCx

Meaning

The frame unit controller board has detected that the digital

signalling processing unit attempts to send too much data to the

carrier unit (via the FQHU or the DFHU).

This alarm does not affect the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 45 (1095)

7007 TRX/FU: TOO MANY BYTES IN DATA FROM DSPx TO FUCx

Page 46: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the DSPxs and the FUCx one by one

until the fault situation is over.

Cancelling

This is a transient-type alarm. No cancelling.

46 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 47: Alarm

9 7008 TRX/FU: NO DATA FROM CU TO FUIN PRIMARY LINK

Meaning

The frame unit has detected that no data is coming in from the carrier

unit (CU) to the frame unit (FU). This alarm concerns the primary data

link between the CU and the FU, which goes via the primary FQHU or DFHU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 47 (1095)

7008 TRX/FU: NO DATA FROM CU TO FU IN PRIMARY LINK

Page 48: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

primary FQHU one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

48 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 49: Alarm

10 7009 TRX/FU: NO DATA FROM CU TO FUIN REDUNDANT/DIVERSITY LINK

Meaning

The frame unit has detected that no data is coming in from the carrier

unit (CU) to the frame unit (FU). This alarm concerns the redundant or

diversity data link between CU and FU, which goes via the redundant or

diversity FQHU or DFHU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 49 (1095)

7009 TRX/FU: NO DATA FROM CU TO FU IN REDUNDANT/DIVERSITY LINK

Page 50: Alarm

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

redundant/diversity FQHU one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

50 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 51: Alarm

11 7010 TRX/FU: BIE-FUCx LINK A FAILUREMeaning

The data clock signal from the BIE 1 (Base Station Interface Equipment)

is missing. If the clock signal is missing, data cannot be transferred

between the FUCx and BIE 1.

The fatality of this alarm depends on whether a redundant BIE is

installed.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 51 (1095)

7010 TRX/FU: BIE-FUCx LINK A FAILURE

Page 52: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

If only one BIE is installed:

1. Check the cable between the FUCx and the BIE.

2. Check that the BIE units function.

3. Change the FUCx.

If the redundant BIE is installed, this alarm with any alarm from the

BIE 1 indicates that a switchover to the redundant BIE has occurred and

the TRX can operate normally. Otherwise this is a fatal alarm requiring

the same measures as described above.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

52 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 53: Alarm

12 7011 TRX/FU: BIE-FUCx LINK B FAILUREMeaning

The data clock signal from the BIE 2 (Base Station Interface Equipment)

is missing. If the clock signal is missing, data cannot be transferred

between the FUCx and BIE 2.

The fatality of this alarm depends on whether a redundant BIE is

installed.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 53 (1095)

7011 TRX/FU: BIE-FUCx LINK B FAILURE

Page 54: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

If only one BIE is installed:

1. Check the cable between the FUCx and the BIE.

2. Check that the BIE units function.

3. Change the FUCx.

If the redundant BIE is installed, this alarm with any alarm from the

BIE 2 indicates that a switchover to the primary BIE has occurred and

the TRX can operate normally. Otherwise this is a fatal alarm requiring

the same measures as described above.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

54 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 55: Alarm

13 7012 TRX/FU: BIE-FUCx LINK A AND BFAULTY

Meaning

The data clock signals from the BIE1 and BIE2 (Base station Interface

Equipment) are missing. If the clock signals are missing, data cannot

be transferred between this frame unit (FU) and BSC.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 55 (1095)

7012 TRX/FU: BIE-FUCx LINK A AND B FAULTY

Page 56: Alarm

3) slot 6) subunit number

See alarm instructions

Instructions

Do the following operations and repair when needed:

- Check the incoming Abis signal in BIE

- Check the cable between the FUCx and BIE,

- Check that the BIE units function,

If these measures have no effect, change the FUCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

56 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 57: Alarm

14 7013 TRX/FU: BIE-FUCx LINK A DRIVERFAILURE

Meaning

An error is detected in the testing of the driver circuits of BIE's

link A. Data can not be transferred between the BIE 1 and the FUCx

if the driver circuits of link A are faulty.

The fatality of this alarm depends on whether a redundant BIE is

installed.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 57 (1095)

7013 TRX/FU: BIE-FUCx LINK A DRIVER FAILURE

Page 58: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

58 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 59: Alarm

15 7014 TRX/FU: BIE-FUCx LINK B DRIVERFAILURE

Meaning

An error is detected in the testing of the driver circuits of the

BIE's link B. Data can not be transferred between the BIE 2 and

the FUCx if the driver circuits of link B are faulty.

The fatality of this alarm depends on whether a redundant BIE is

installed.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 59 (1095)

7014 TRX/FU: BIE-FUCx LINK B DRIVER FAILURE

Page 60: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

60 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 61: Alarm

16 7016 TRX/FU: GSM TIMESLOTUNATTAINABLE

Meaning

The speech and data connection to the specified GSM time slot is faulty

in the base station interface. The frame unit controller (FUC) tries to

recover the fault situation by reinitializing the time-slot-specific

part of the interface. If the reinitialization does not succeed to

clear the fault situation, this alarm is activated.

This alarm affects the provided service. If this GSM time slot is used

for mobile calls, the calls do not succeed when this alarm is active.

BSI

The base station interface (BSI) is the interface connecting the frame

unit controller (FUC) and the base station interface equipment (BIE).

All telecommunications traffic to or from the TRX goes through the

base station interface.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

1. Check the operation of the base station interface equipment (BIE).

2. If the BIE is in order, change the FUCx.

3. If the alarm does not disappear, change one DSPx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 61 (1095)

7016 TRX/FU: GSM TIMESLOT UNATTAINABLE

Page 62: Alarm

4. If this does not help, change the other DSPx.

5. If the alarm is still active, check the transmission line

to or from the base station controller (BSC).

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

62 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 63: Alarm

17 7017 TRX/FU: FAILURE IN BASESTATION INTERFACE

Meaning

Recovery of the FUCx HDLC (8071) link controller has failed. The HDLC

link controller handles both signalling and traffic data between the

BSC and the FU. Due to this alarm, the frame unit controller (FUC) is

reset. The alarm can reoccur after the reset.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 63 (1095)

7017 TRX/FU: FAILURE IN BASE STATION INTERFACE

Page 64: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

64 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 65: Alarm

18 7020 TRX/FU: MCLx1-FUCx LINKFAILURE

Meaning

The incoming clock link from the MCLx 1 is faulty.

The fatality of this alarm depends on whether a redundant MCLx is

installed.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 65 (1095)

7020 TRX/FU: MCLx1-FUCx LINK FAILURE

Page 66: Alarm

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm is given if no clock signals are coming in from the MCLx1.

This may be caused by the following reasons:

- the FUCx is faulty

- there is a fault in the clock cables or in the TRX subrack

Change the FUCx. If it does not help, check the cabling of the clock

signals.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

66 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 67: Alarm

19 7021 TRX/FU: MCLx2-FUCx LINKFAILURE

Meaning

The incoming clock link from the MCLx 2 is faulty.

The fatality of this alarm depends on whether a redundant MCLx is

installed.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 67 (1095)

7021 TRX/FU: MCLx2-FUCx LINK FAILURE

Page 68: Alarm

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm is given if no clock signals are coming in from the MCLx2.

This may be caused by the following reasons:

- the FUCx is faulty;

- there is a fault in the clock cables or in the TRX subrack.

Change the FUCx. If it does not help, check the cabling of the clock

signals.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

68 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 69: Alarm

20 7022 TRX/FU: BOTH MCLx-FUCx LINKSFAILURE

Meaning

The incoming clock links from both MCLxs are faulty.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 69 (1095)

7022 TRX/FU: BOTH MCLx-FUCx LINKS FAILURE

Page 70: Alarm

3) slot 6) subunit number

See alarm instructions

Instructions

The alarm is given if no clock signals are coming in from

the MCLx units.

This may be caused by the following reasons:

- the FUCx is faulty;

- there is a fault in the clock cables or in the TRX subrack.

The alarm causes a reset of the FUCx. If the card is not operative

any longer, change the FUCx. If the alarm does not disappear after

changing the FUCx, check the cabling of the clock signals.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

70 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 71: Alarm

21 7023 TRX/FU: FUCx INTERNAL CLOCKFAILURE

Meaning

The internal GSM timing signals of the FUCx are missing.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 71 (1095)

7023 TRX/FU: FUCx INTERNAL CLOCK FAILURE

Page 72: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

A single alarm does not call for measures. The alarm may occur when the

MCLx connection is being changed. It disappears after a successful

change. If it does not, change the FUCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

72 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 73: Alarm

22 7024 TRX/FU: PARITY ERROR ININCOMING FN

Meaning

There is a parity error in the incoming frame number from the MCLx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 73 (1095)

7024 TRX/FU: PARITY ERROR IN INCOMING FN

Page 74: Alarm

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

74 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 75: Alarm

23 7030 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU1

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has received data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 75 (1095)

7030 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU1

Page 76: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

76 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 77: Alarm

24 7031 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU2

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has received data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 77 (1095)

7031 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU2

Page 78: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

78 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 79: Alarm

25 7032 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU3

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 79 (1095)

7032 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU3

Page 80: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

80 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 81: Alarm

26 7033 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU4

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 81 (1095)

7033 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU4

Page 82: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

82 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 83: Alarm

27 7034 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU5

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 83 (1095)

7034 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU5

Page 84: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

84 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 85: Alarm

28 7035 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU6

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 85 (1095)

7035 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU6

Page 86: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

86 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 87: Alarm

29 7036 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU7

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 87 (1095)

7036 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU7

Page 88: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

88 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 89: Alarm

30 7037 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU8

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 89 (1095)

7037 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU8

Page 90: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

90 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 91: Alarm

31 7038 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU9

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 91 (1095)

7038 TRX/FU: DATA TRANSFER ERROR BETWEEN FU AND CU9

Page 92: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

92 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 93: Alarm

32 7039 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU10

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 93 (1095)

7039 TRX/FU: DATA TRANSFER ERROR BETWEEN FU ANDCU10

Page 94: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

94 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 95: Alarm

33 7040 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU11

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 95 (1095)

7040 TRX/FU: DATA TRANSFER ERROR BETWEEN FU ANDCU11

Page 96: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

96 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 97: Alarm

34 7041 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU12

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 97 (1095)

7041 TRX/FU: DATA TRANSFER ERROR BETWEEN FU ANDCU12

Page 98: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the TXUA, the primary RXUA, the FUCx and the

DSPxs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

98 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 99: Alarm

35 7042 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU13

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 99 (1095)

7042 TRX/FU: DATA TRANSFER ERROR BETWEEN FU ANDCU13

Page 100: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

100 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 101: Alarm

36 7043 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU14

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 101 (1095)

7043 TRX/FU: DATA TRANSFER ERROR BETWEEN FU ANDCU14

Page 102: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and

the FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

102 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 103: Alarm

37 7044 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU15

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 103 (1095)

7044 TRX/FU: DATA TRANSFER ERROR BETWEEN FU ANDCU15

Page 104: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

104 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 105: Alarm

38 7045 TRX/FU: DATA TRANSFER ERRORBETWEEN FU AND CU16

Meaning

The frame unit (FU) has detected a data transfer error between the FU

and the carrier unit (CU). The data from the FU has gone to a wrong CU

or the FU has got data from a wrong CU.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 105 (1095)

7045 TRX/FU: DATA TRANSFER ERROR BETWEEN FU ANDCU16

Page 106: Alarm

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

DFHU

The dummy frequency hopping unit (DFHU) connects the FUs and the

CUs transparently together, that is, the FU1 is connected to the

CU1 and so on.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the FUCx, the DSPxs, the TXUx and the

FQHUs one by one until the fault situation is over.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

106 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 107: Alarm

39 7050 TRX/FU: DISCREPANCY OF THEFRAME NUMBER BETWEEN FUCx ANDDSPx

Meaning

The frame numbers of the FUCx and the DSPxs differ.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 107 (1095)

7050 TRX/FU: DISCREPANCY OF THE FRAME NUMBERBETWEEN FUCx AND DSPx

Page 108: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

The FUCx automatically corrects the frame number. If the alarm recurs

several times, change the FUCx. If the alarm does not disappear, change

both DSPxs.

Cancelling

This is an alarm of transient type, no cancelling.

108 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 109: Alarm

40 7051 TRX/FU: CIPHERING CAPABILITIESOF DSPxs IN ONE TRX DIFFER

Meaning

The ciphering capability of one DSPx differs from that of the

other DSPx in the FU. The DSPxs in the FU are not of the same type.

This alarm can only be issued during the startup.

This information concerns an unsupported feature.

FU

The frame unit includes all control and baseband functions related to

each speech connection. The frame unit consists of three digital

boards: a frame unit controller and two identical digital signal

processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling between

the base station controller and the mobile station. The FUCx relays

all traffic data between the BIE and the DSPxs and between the DSPxs

and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all base band

operations for traffic data e.g. encryption/decryption,

coding/decoding, demodulation and combining of RF signals in the case

of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) RACK (CABINET) NUMBER 4) TYPE OF UNIT

2) SHELF NUMBER 5) UNIT NUMBER

3) SLOT 6) SUBUNIT NUMBER

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 109 (1095)

7051 TRX/FU: CIPHERING CAPABILITIES OF DSPxs IN ONE TRXDIFFER

Page 110: Alarm

Instructions

Change the DSPxs to the same type. If they are of the same type and

the alarm does not disappear, change one DSPx. If this does not help,

change the other DSPx.

Cancelling

This is an alarm of transient type, no cancelling.

110 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 111: Alarm

41 7052 TRX/FU: DSPx, ENCRYPTIONALGORITHM A5/1 CAN NOT BEEXECUTED

Meaning

The DSPx is not able to execute the GSM encryption algorithm A5/1.

Wrong type of the DSPx is included in the FU or there is a failure in

the DSPx. This alarm can only be issued during the startup when there

is BTS software which is able to execute the A5/1.

This information concerns an unsupported feature.

FU

The frame unit includes all control and baseband functions related to

each speech connection. The frame unit consists of three digital

boards: a frame unit controller and two identical digital signal

processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling between

the base station controller and the mobile station. The FUCx relays

all traffic data between the BIE and the DSPxs and between the DSPxs

and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all base band

operations for traffic data e.g. encryption/decryption,

coding/decoding, demodulation and combining of RF signals in the case

of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) RACK (CABINET) NUMBER 4) TYPE OF UNIT

2) SHELF NUMBER 5) UNIT NUMBER

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 111 (1095)

7052 TRX/FU: DSPx, ENCRYPTION ALGORITHM A5/1 CAN NOTBE EXECUTED

Page 112: Alarm

3) SLOT 6) SUBUNIT NUMBER

See alarm instructions.

Instructions

Change the DSPx whose type is DSPC to a type which can execute the

encryption algorithm A5/1. If it is already of such a type, change

one DSPx. If this does not help, change the other DSPx.

Cancelling

This is an alarm of transient type, no cancelling.

112 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 113: Alarm

42 7054 TRX/FU: TRX DOES NOT SUPPORTHALF RATE (TCH/H) CONFIGURATION

Meaning

There has been an attempt to configure the half rate channel (TCH/H)

to the FU which does not support half rate channels.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions related to

each speech connection. The frame unit consists of three digital

boards: a frame unit controller and two identical digital signal

processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling between

the base station controller and the mobile station. The FUCx relays

all traffic data between the BIE and the DSPxs and between the DSPxs

and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all base band

operations for traffic data e.g. encryption/decryption,

coding/decoding, demodulation and combining of RF signals in the case

of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 113 (1095)

7054 TRX/FU: TRX DOES NOT SUPPORT HALF RATE (TCH/H)CONFIGURATION

Page 114: Alarm

Instructions

Change the full rate (TCH/F) configuration back to all TCH timeslots

of the FU.

If the half rate configuration is needed and the BTS SW 8.0 is in use,

the software must be changed to 9.0 or newer.

If the half rate configuration is needed and the BTS SW 9.0 or newer

is in use, check the HW configuration. Both DSPxs of the FU must

support the half rate configuration.

Cancelling

This is an alarm of transient type, no cancelling.

114 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 115: Alarm

43 7060 TRX/FU: FUCx-DSPx, NORESPONSE FROM DSPx

Meaning

No response from the DSPx. There is a connection failure in the

interface between the FUCx and the DSPx. Due to this alarm, the

frame unit controller (FUC) is reset. The alarm can recur after

the reset.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 115 (1095)

7060 TRX/FU: FUCx-DSPx, NO RESPONSE FROM DSPx

Page 116: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

116 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 117: Alarm

44 7061 TRX/FU: FUCx-DSPx, ILLEGALSIGN TYPE IN SIM-MESSAGE

Meaning

There is an illegal signalling type in the signalling message from

the FUCx to the DSPx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 117 (1095)

7061 TRX/FU: FUCx-DSPx, ILLEGAL SIGN TYPE IN SIM-MESSAGE

Page 118: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

118 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 119: Alarm

45 7062 TRX/FU: FUCx-DSPx, ILLEGALCHAN COMB IN TSC-MESSAGE

Meaning

There is an illegal channel combination in the time slot configuration

message from the FUCx to the DSPx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 119 (1095)

7062 TRX/FU: FUCx-DSPx, ILLEGAL CHAN COMB IN TSC-MESSAGE

Page 120: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

120 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 121: Alarm

46 7063 FUCx-DSPx, ILLEGAL TIME SLOTNo. IN TSC-MESSAGE

Meaning

There is an illegal time slot number in the time slot configuration

message from the FUCx to the DSPx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 121 (1095)

7063 FUCx-DSPx, ILLEGAL TIME SLOT No. IN TSC-MESSAGE

Page 122: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

122 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 123: Alarm

47 7064 TRX/FU: FUCx-DSPx, ILLEGALSUBCHANNEL No. IN SIM-MESSAGE

Meaning

There is an illegal subchannel number in the signalling message

from the FUCx to the DSPx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 123 (1095)

7064 TRX/FU: FUCx-DSPx, ILLEGAL SUBCHANNEL No. IN SIM-MESSAGE

Page 124: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

124 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 125: Alarm

48 7065 TRX/FU: FUCx-DSPx, ILLEGALSUBCHANNEL No. IN HL1-MESSAGE

Meaning

There is an illegal subchannel number in the HL1 message from

the FUCx to the DSPx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 125 (1095)

7065 TRX/FU: FUCx-DSPx, ILLEGAL SUBCHANNEL No. IN HL1-MESSAGE

Page 126: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

126 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 127: Alarm

49 7066 TRX/FU: FUCx-DSPx, ILLEGALSUBCHANNEL No. IN CHC-MESSAGE

Meaning

There is an illegal subchannel number in the channel configuration

message from the FUCx to the DSPx.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 127 (1095)

7066 TRX/FU: FUCx-DSPx, ILLEGAL SUBCHANNEL No. IN CHC-MESSAGE

Page 128: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

128 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 129: Alarm

50 7067 TRX/FU: FUCx-DSPx, NO FRAMENUMBER FROM DSPx

Meaning

There is no response from the DSPx to the frame number (FN) poll.

A connection failure has occurred in the interface between the FUCx

and the DSPx. Due to this alarm, the frame unit controller (FUC)

is reset. The alarm can reoccur after the reset.

This alarm affects the provided service.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 129 (1095)

7067 TRX/FU: FUCx-DSPx, NO FRAME NUMBER FROM DSPx

Page 130: Alarm

Instructions

Change the FUCx. If the alarm does not disappear, change one DSPx.

If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

130 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 131: Alarm

51 7068 TRX/FU: DSPx, NO RESULT FROMDSP BOARD TEST

Meaning

The FUCx does not get the DSP board test result from the DSPx. This

alarm can only be issued during the startup.

This alarm affects the provided service.

FU

The frame unit includes all control and baseband functions related to

each speech connection. The frame unit consists of three digital

boards: a frame unit controller and two identical digital signal

processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling between

the base station controller and the mobile station. The FUCx relays

all traffic data between the BIE and the DSPxs and between the DSPxs

and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all base band

operations for traffic data e.g. encryption/decryption,

coding/decoding, demodulation and combining of RF signals in the case

of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 131 (1095)

7068 TRX/FU: DSPx, NO RESULT FROM DSP BOARD TEST

Page 132: Alarm

Instructions

Change one DSPx. If this does not help, change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

132 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 133: Alarm

52 7069 TRX/FU: TRAFFIC SPEEDCABABILITIES OF DSP UNIT DIFFER INTRX

Meaning

The traffic speed capability of one DSPx differs from that of the

other DSPx in the FU. The DSPxs in the FU are not of same type.

This alarm can only be issued during the startup.

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 133 (1095)

7069 TRX/FU: TRAFFIC SPEED CABABILITIES OF DSP UNITDIFFER IN TRX

Page 134: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the DSPxs to the same type. If they are of same type and the

alarm does not disappear, change one DSPx. If this does not help,

change the other DSPx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

134 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 135: Alarm

53 7100 BCF/RFTE: HIGH SIGNAL LEVEL(>-70 DBM) IN THE RFTE OUTPUT

Meaning

The signal detecting line of the RFTE has measured a higher signal

level than -70 dBm in the RFTE output. The time slots which are not

used for the RFTE tests are supervised.

This alarm affects the provided service because normally it indicates

that there is an interfering leaking signal from the RFTE to the BTS

receiver path.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check external disturbances. If there are none, change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 135 (1095)

7100 BCF/RFTE: HIGH SIGNAL LEVEL (>-70 DBM) IN THE RFTEOUTPUT

Page 136: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

136 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 137: Alarm

54 7101 BCF/RFTE: SYNTHESIZER NOTLOCKED OR REF FREQ 1&2 MISSING

Meaning

The RFTE's synthesizers are not locked and the RFTE is not functioning

properly.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 137 (1095)

7101 BCF/RFTE: SYNTHESIZER NOT LOCKED OR REF FREQ1&2 MISSING

Page 138: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

138 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 139: Alarm

55 7102 BCF/RFTE: SELF TEST FAILUREMeaning

The alarm logic monitors the operation of the RFTE. If there is a

selftest (runtime) failure, the alarm is activated.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7102 is not cancelled, change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 139 (1095)

7102 BCF/RFTE: SELF TEST FAILURE

Page 140: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

140 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 141: Alarm

56 7103 BCF/RFTE: MCLx1-RFTE CLOCKFAILURE

Meaning

The frame clock from the MCLU1 is missing.

This alarm does not affect the provided services.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 141 (1095)

7103 BCF/RFTE: MCLx1-RFTE CLOCK FAILURE

Page 142: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

142 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 143: Alarm

57 7104 BCF/RFTE: MCLx2-RFTE CLOCKFAILURE

Meaning

The frame clock from the MCLU2 is missing.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 143 (1095)

7104 BCF/RFTE: MCLx2-RFTE CLOCK FAILURE

Page 144: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

144 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 145: Alarm

58 7105 BCF/RFTE: MCLx1-RFTE OCTALBIT CLOCK FAILURE

Meaning

The octal bit clock from the MCLU1 is missing.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 145 (1095)

7105 BCF/RFTE: MCLx1-RFTE OCTAL BIT CLOCK FAILURE

Page 146: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

146 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 147: Alarm

59 7106 BCF/RFTE: MCLx2-RFTE OCTALBIT CLOCK FAILURE

Meaning

The octal bit clock from the MCLx2 is missing.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 147 (1095)

7106 BCF/RFTE: MCLx2-RFTE OCTAL BIT CLOCK FAILURE

Page 148: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

148 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 149: Alarm

60 7107 BCF/RFTE: MCLx1-RFTEREFERENCE FREQUENCY FAILURE

Meaning

The 2.6 MHz reference frequency from the MCLx1 is missing.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 149 (1095)

7107 BCF/RFTE: MCLx1-RFTE REFERENCE FREQUENCYFAILURE

Page 150: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

150 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 151: Alarm

61 7108 BCF/RFTE: MCLx2-RFTEREFERENCE FREQUENCY FAILURE

Meaning

The 2.6 MHz reference frequency from the MCLx2 is missing.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 151 (1095)

7108 BCF/RFTE: MCLx2-RFTE REFERENCE FREQUENCYFAILURE

Page 152: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

152 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 153: Alarm

62 7109 BCF/RFTE: NO PARAMETERSGIVEN TO UNIT

Meaning

The RFTE has not received initialization parameters from the OMU.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7109 is not cancelled, change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 153 (1095)

7109 BCF/RFTE: NO PARAMETERS GIVEN TO UNIT

Page 154: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

154 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 155: Alarm

63 7110 BCF/RFTE: OMU-RFTECONNECTION FAILURE

Meaning

There is an RFTE failure in the Q1-relay test. The RFTE has

disconnected itself from the Q1 link and does not respond to any

commands given by the OMU unit.

This alarm does not affect the provided service.

RFTE

The radio frequency test equipment (RFTE) is used to test the operation

of the BTS. The possible tests are radio loop and receiver antenna

(RAX) tests. These tests can be started locally at the cell site or

remotely from the OMC/BSC. Because the test loops are made inside the

BTS, the RFTE's main task is to convert the test signal from the transmit

band to the receive band.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RFTE.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 155 (1095)

7110 BCF/RFTE: OMU-RFTE CONNECTION FAILURE

Page 156: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

156 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 157: Alarm

64 7120 TRX/CU: TXUx - FQHU INTERFACE1 FAILURE

Meaning

Errors have occurred when the TXUx has been testing the frequency

hopping interface 1 (FHI1).

This alarm does not affect the provided service if both FQHU units

are installed.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 157 (1095)

7120 TRX/CU: TXUx - FQHU INTERFACE 1 FAILURE

Page 158: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

158 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 159: Alarm

65 7121 TRX/CU: TXUx - FQHU INTERFACE2 FAILURE

Meaning

Errors have occurred when the TXUx has been testing the frequency

hopping interface 2 (FHI2).

This alarm does not affect the provided service if both FQHU

units are equipped.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 159 (1095)

7121 TRX/CU: TXUx - FQHU INTERFACE 2 FAILURE

Page 160: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

160 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 161: Alarm

66 7122 TRX/CU: RXUA SELF TESTFAILURE

Meaning

The alarm logic monitors the operation of the RXUA. The alarm is

activated if there is a selftest (runtime) failure.

The fatality of this alarm depends on whether diversity is used. If

the CU has been equipped with a diversity receiver, then alarm 7122

does not stop the operation of the TRX/CU.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 161 (1095)

7122 TRX/CU: RXUA SELF TEST FAILURE

Page 162: Alarm

Instructions

Check whether alarm 7211 (BCF/OMU: REINITIALIZATION OF THE UNIT

FAILED) is activated by the same TRX. If 7211 is active, then alarm

7122 is not cancelled automatically.

If 7122 is not cancelled, change the RXUA.

Cancelling

This is a start/cancel type alarm. This alarm is not cancelled in all

cases even if the fault condition is over. If alarm 7211 is also

active, then the TRX/BTS lock/unlock command is required.

162 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 163: Alarm

67 7123 TRX/CU: DIVERSITY RXUA SELFTEST FAILURE

Meaning

The alarm logic monitors the operation of the RXUA. The alarm is

activated if there is a selftest (runtime) failure.

This alarm does not affect the provided service. The services are

maintained by the primary unit.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check whether alarm 7211 (BCF/OMU: REINITIALIZATION OF THE UNIT

FAILED) is activated by the same TRX. If alarm 7211 is active,

then alarm 7123 is not cancelled automatically.

If alarm 7123 is not cancelled, change the diversity RXUA.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 163 (1095)

7123 TRX/CU: DIVERSITY RXUA SELF TEST FAILURE

Page 164: Alarm

Cancelling

This is a start/cancel type alarm. It is not cancelled in all

cases even if the fault condition is over. If alarm 7211 is also

active, then the TRX/BTS lock/unlock command is required.

164 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 165: Alarm

68 7124 TRX/CU: HARDWARE FAILURE INRXUA

Meaning

The RF amplifier in the RXUA is faulty.

The fatality of this alarm depends on whether diversity is used.

If the CU is equipped with a diversity RXUA, then alarm 7124 does not

stop the operation of the TRX/CU.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check whether alarm 7211 (BCF/OMU: REINITIALIZATION OF THE UNIT

FAILED) is activated by the same TRX. If alarm 7211 is active, then

alarm 7124 is not cancelled automatically.

If alarm 7124 is not cancelled, change the RXUA.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 165 (1095)

7124 TRX/CU: HARDWARE FAILURE IN RXUA

Page 166: Alarm

Cancelling

This is a start/cancel type alarm. It is not cancelled in all

cases even if the fault condition is over. If alarm 7211 is also

active, then the TRX/BTS lock/unlock command is required.

166 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 167: Alarm

69 7125 TRX/CU: HARDWARE FAILURE INDIVERSITY RXUA

Meaning

The RF amplifier in the RXUA is faulty.

This alarm does not affect the provided service. The service is

maintained by the primary unit.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check whether alarm 7211 (BCF/OMU: REINITIALIZATION OF THE UNIT

FAILED) is activated by the same TRX. If alarm 7211 is active,

then alarm 7125 is not cancelled automatically.

If alarm 7125 is not cancelled, change the diversity RXUA.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 167 (1095)

7125 TRX/CU: HARDWARE FAILURE IN DIVERSITY RXUA

Page 168: Alarm

Cancelling

This is a start/cancel type alarm. It is not cancelled in all

cases even if the fault condition is over. If alarm 7211 is also

active, then the TRX/BTS lock/unlock command is required.

168 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 169: Alarm

70 7126 TRX/CU: RXUA SYNTHESIZER NOTLOCKED

Meaning

The RXUA synthesizer is not locked.

The fatality of this alarm depends on whether diversity is used.

If the CU is equipped with a diversity RXUA, then alarm 7126 does

not stop the operation of the TRX/CU.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check whether alarm 7211 (BCF/OMU: REINITIALIZATION OF THE UNIT

FAILED) is activated by the same TRX. If alarm 7211 is active, then

alarm 7126 is not cancelled automatically.

If alarm 7126 is not cancelled, change the RXUA.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 169 (1095)

7126 TRX/CU: RXUA SYNTHESIZER NOT LOCKED

Page 170: Alarm

Cancelling

This is a start/cancel type alarm. It is not cancelled in all cases

even though the fault condition is over. If alarm 7211 is also active,

then the TRX/BTS lock/unlock command is required.

170 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 171: Alarm

71 7127 TRX/CU: DIVERSITY RXUASYNTHESIZER NOT LOCKED

Meaning

The diversity RXUA synthesizer is not locked.

This alarm does not affect the provided service. The service is

maintained by the primary unit.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check whether alarm 7211 (BCF/OMU: REINITIALIZATION OF THE UNIT

FAILED) is activated by the same TRX. If alarm 7211 is active, then

alarm 7127 is not cancelled automatically.

If alarm 7127 is not cancelled, change the diversity RXUA.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 171 (1095)

7127 TRX/CU: DIVERSITY RXUA SYNTHESIZER NOT LOCKED

Page 172: Alarm

Cancelling

This is a start/cancel type alarm. It is not cancelled in all cases

even though the fault condition is over. If alarm 7211 is also active,

then the TRX/BTS lock/unlock command is required.

172 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 173: Alarm

72 7128 TRX/CU: TXUx - COMBINERCONNECTION FAILURE

Meaning

The voltage standing wave ratio (VSWR) in the TXUx power output to the

combiner exceeds value 3. The alarm occurs, for example, when the cable

between the TXUx and the combiner unit is not connected.

This alarm affects the provided service. Alarm 7128 stops

the operation of the TXUx.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the cable between the TXUx and the combiner. If the alarm is

still on, the transmitter or the combiner is faulty.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 173 (1095)

7128 TRX/CU: TXUx - COMBINER CONNECTION FAILURE

Page 174: Alarm

Cancelling

This is a start/cancel type alarm. This alarm is not cancelled

even if the fault condition is over. Give the BLOCK/UNBLOCK command

at the cell site from the OMU-MMI terminal, or the TRX/BTS lock/unlock

command remotely from the BSC-MML terminal.

174 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 175: Alarm

73 7129 TRX/CU: TXUx OUTPUT POWERDECREACED

Meaning

The TXUx output power has decreased to half of the original

value (-3 dB). There is a hardware failure in the TXUx.

This alarm affects the provided service. Alarm 7129 stops the

operation of the TXUx.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 175 (1095)

7129 TRX/CU: TXUx OUTPUT POWER DECREACED

Page 176: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

176 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 177: Alarm

74 7130 TRX/CU: TXUx LOWERTEMPERATURE ALARM

Meaning

The temperature of the TXUx mechanics has reached the lower alarm

level.

This alarm does not affect the provided service.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the cabinet fans and air condition at the cell site.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 177 (1095)

7130 TRX/CU: TXUx LOWER TEMPERATURE ALARM

Page 178: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

178 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 179: Alarm

75 7131 TRX/CU: TXUx TEMPERATURETOO HIGH

Meaning

The temperature of the TXUx mechanics is too high.

This alarm affects the provided service. Alarm 7131 stops the

operation of the TXUx.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The CU starts functioning normally when the temperature has gone down.

Check the cabinet fans and the air condition at the cell site. If the

temperature of the CU is normal and alarm 7131 is still on, change

the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 179 (1095)

7131 TRX/CU: TXUx TEMPERATURE TOO HIGH

Page 180: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

180 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 181: Alarm

76 7132 TRX/CU: TXUx SYNTHESIZER NOTLOCKED,

Meaning

The TXUx synthesizer is not locked.

This alarm affects the provided service. Alarm 7132 stops the

operation of the TXUx.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7132 is not cancelled, change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 181 (1095)

7132 TRX/CU: TXUx SYNTHESIZER NOT LOCKED,

Page 182: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

182 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 183: Alarm

77 7133 TRX/CU: MCLx1 - TXUx FRAMECLOCK FAILURE

Meaning

The frame clock from the MCLx1 is missing.

The fatality of this alarm depends on whether a redundant MCLx

is installed.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 183 (1095)

7133 TRX/CU: MCLx1 - TXUx FRAME CLOCK FAILURE

Page 184: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

184 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 185: Alarm

78 7134 TRX/CU: MCLx2 - TXUx FRAMECLOCK FAILURE

Meaning

The frame clock from the MCLx2 is missing.

The fatality of this alarm depends on whether a redundant MCLx

is installed.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 185 (1095)

7134 TRX/CU: MCLx2 - TXUx FRAME CLOCK FAILURE

Page 186: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

186 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 187: Alarm

79 7135 TRX/CU: MCLx1 - TXUx OCTAL BITCLOCK FAILURE

Meaning

The octal bit clock from the MCLx1 is missing.

The fatality of this alarm depends on whether a redundant MCLx

is installed.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 187 (1095)

7135 TRX/CU: MCLx1 - TXUx OCTAL BIT CLOCK FAILURE

Page 188: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

188 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 189: Alarm

80 7136 TRX/CU: MCLx2 - TXUx OCTAL BITCLOCK FAILURE

Meaning

The octal bit clock from the MCLx2 is missing.

The fatality of this alarm depends on whether a redundant MCLx

is installed.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 189 (1095)

7136 TRX/CU: MCLx2 - TXUx OCTAL BIT CLOCK FAILURE

Page 190: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

190 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 191: Alarm

81 7137 TRX/CU: MCLx1 - TXUxREFERENCE FREQUENCY FAILURE

Meaning

The reference frequency (2.6 MHz) from MCLx1 is missing.

The fatality of this alarm depends on whether a redundant MCLx

is installed.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 191 (1095)

7137 TRX/CU: MCLx1 - TXUx REFERENCE FREQUENCYFAILURE

Page 192: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

192 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 193: Alarm

82 7138 TRX/CU: MCLx2 - TXUxREFERENCE FREQUENCY FAILURE

Meaning

The reference frequency (2.6 MHz) from the MCLx2 is missing.

The fatality of this alarm depends on whether a redundant MCLx

is installed.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 193 (1095)

7138 TRX/CU: MCLx2 - TXUx REFERENCE FREQUENCYFAILURE

Page 194: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

194 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 195: Alarm

83 7139 TRX/CU: NO PARAMETERS GIVENTO UNIT

Meaning

The CU has not received initialization parameters from the OMU.

This alarm affects the provided service. Alarm 7139 stops the

operation of the TXUx.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7139 is not cancelled, change the TXUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 195 (1095)

7139 TRX/CU: NO PARAMETERS GIVEN TO UNIT

Page 196: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

196 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 197: Alarm

84 7140 TRX/CU: EXTENDED RANGE CELLNOT SUPPORTED

Meaning

The TXUx does not support the Extended Range Cell feature. The alarm

is issued when the TXUx does not recognize the transmitting timing

advancement command. This could be the case when the version of the

TXUx is old.

This alarm affects service. It stops the operation of the TRX.

CU, TXUx and RXUA

Carrier Unit (CU) is located in the radio interface in the BTS.

The main function of the CU is to convert the base band signal to

the radio frequency signal and vice versa. The CU consists of

a transmitter (TXUx) and one or two receivers (RXUAs) depending on

whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check that the HW version of the TXUx unit is correct. If the alarm is

still on, the TXUx is faulty and must be replaced.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 197 (1095)

7140 TRX/CU: EXTENDED RANGE CELL NOT SUPPORTED

Page 198: Alarm

Cancelling

This is a start/cancel type alarm. It is not cancelled only by

changing a new TXUx to the TRX. To cancel the alarm, give the

BLOCK/DEBLOCK command of the OMU MMI on the cell site or the TRX/BTS

lock/unlock command of the BSC MML remotely.

198 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 199: Alarm

85 7141 TRX/CU: INVALID RADIUSEXTENSION OF EXTENDED RANGECELL

Meaning

The radius extension parameter in the Extended Range Cell concept is

not correct. The alarm is issued when this parameter is sent to the

TXUx and it is out of the accepted range.

This alarm affects the service. It stops the operation of the TRX.

CU, TXUx and RXUA

Carrier Unit (CU) is located in the radio interface in the BTS.

The main function of the CU is to convert the base band signal to

the radio frequency signal and vice versa. The CU consists of

a transmitter (TXUx) and one or two receivers (RXUAs) depending on

whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check that the radius extension parameter in the HW database and in

the BSC is correct. If the alarm is still on, the TXUx is faulty and

must be replaced.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 199 (1095)

7141 TRX/CU: INVALID RADIUS EXTENSION OF EXTENDEDRANGE CELL

Page 200: Alarm

Cancelling

This is a start/cancel type alarm. It is not cancelled although

the fault condition is cleared. To cancel the alarm, give the

BLOCK/DEBLOCK command of the OMU MMI on the cell site or the TRX/BTS

lock/unlock command of the BSC MML remotely.

200 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 201: Alarm

86 7150 BCF/MCLx: 13 MHZ FREQUENCYFROM OVEN OSCILLATOR MISSING

Meaning

The master clock unit's oscillator is unable to send the

correct frequency.

The fatality of the alarm depends on whether a redundant master clock

unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and this cell site is unable to transmit

any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the MCLx unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 201 (1095)

7150 BCF/MCLx: 13 MHZ FREQUENCY FROM OVENOSCILLATOR MISSING

Page 202: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

202 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 203: Alarm

87 7151 BCF/MCLx: OVEN OSCILLATORFAILURE

Meaning

The oven oscillator of the master clock unit is alarming.

The temperature control of the oven oscillator may be faulty, or less

than 5 minutes have passed after the power-up and the operating

temperature of the master clock unit's oscillator is not reached.

In these cases, the OMU can not set the unit in any working mode.

The fatality of the alarm depends on whether a redundant master clock

unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and this cell site is unable to transmit

any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 203 (1095)

7151 BCF/MCLx: OVEN OSCILLATOR FAILURE

Page 204: Alarm

Instructions

Change the MCLx unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

204 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 205: Alarm

88 7152 BCF/MCLx: 13 MHZ FREQUENCYFROM REDUNDANT UNIT MISSING

Meaning

The redundant oven oscillator frequency is missing in the master clock

unit. The redundant master clock unit is faulty or the connection between

the master clock units is faulty. If the redundant master clock unit is

absent, this alarm is always off.

The fatality of the alarm depends on whether a redundant master clock

unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and this cell site is unable to transmit

any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 205 (1095)

7152 BCF/MCLx: 13 MHZ FREQUENCY FROM REDUNDANT UNITMISSING

Page 206: Alarm

Instructions

Change the MCLx unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

206 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 207: Alarm

89 7153 BCF/MCLx: LOSS OFSYNCHRONIZATION BETWEENMASTER CLOCK UNITS

Meaning

The master clock units are not synchronized.

This alarm does not affect the provided services.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Determine the faulty MCLx unit by replacing one unit with a functioning

one. If the alarm disappears, the replaced MCLx was the faulty one.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 207 (1095)

7153 BCF/MCLx: LOSS OF SYNCHRONIZATION BETWEENMASTER CLOCK UNITS

Page 208: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

208 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 209: Alarm

90 7154 BCF/MCLx: FAILURE IN LINKBETWEEN TWO MCLx

Meaning

One master clock unit is faulty, or the common status link

between the master clock units is faulty.

This alarm does not affect the provided service. This alarm means

that the communication and the synchronization between the master

clock units is faulty and the clock signals from the master clock

units are asynchronous.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Determine the faulty MCLx unit by replacing one unit with a functioning

one. If the alarm disappears, the replaced MCLx was the faulty one.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 209 (1095)

7154 BCF/MCLx: FAILURE IN LINK BETWEEN TWO MCLx

Page 210: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

210 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 211: Alarm

91 7156 BCF/MCLx: FAILURE IN CLOCKOUTPUT DRIVERS

Meaning

The line drivers of the master clock unit are unable to drive

clock lines.

The fatality of the alarm depends on whether a redundant master clock

unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and this cell site is unable to transmit

any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the MCLx unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 211 (1095)

7156 BCF/MCLx: FAILURE IN CLOCK OUTPUT DRIVERS

Page 212: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

212 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 213: Alarm

92 7157 BCF/MCLx: NO PARAMETERSGIVEN TO UNIT

Meaning

The master clock unit has not received initialization parameters

from the OMU.

The fatality of the alarm depends on whether a redundant the master

clock unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and this cell site is unable to transmit

any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm 7157 is not cancelled, change the MCLx unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 213 (1095)

7157 BCF/MCLx: NO PARAMETERS GIVEN TO UNIT

Page 214: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

214 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 215: Alarm

93 7158 BCF/MCLx: MASTER CLOCK OVENWARMING FAILURE

Meaning

The master clock unit's oscillator has not reached the

operating temperature.

The fatality of the alarm depends on whether a redundant master clock

unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and this cell site is unable to transmit

any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the MCLx unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 215 (1095)

7158 BCF/MCLx: MASTER CLOCK OVEN WARMING FAILURE

Page 216: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

216 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 217: Alarm

94 7159 BCF/MCLx: PCM BASED AUTOTUNING OUT OF RANGE

Meaning

The margin between the actual tuning of the frequency and the upper or

the lower limit of the range of tuning is less than 5% in the PCM-based

auto-tuning function of the master clock unit.

This alarm does not affect the provided service.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the MCLx unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 217 (1095)

7159 BCF/MCLx: PCM BASED AUTO TUNING OUT OF RANGE

Page 218: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

218 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 219: Alarm

95 7160 BCF/MCLx: LOSS OF PCM-SYNCHRONIZATION

Meaning

This alarm is used only when the type of the used master clock unit

is MCLP. The reference frequency from the transmission equipment to

the master clock unit is missing.

This alarm does not affect the provided service. The master clock

unit cannot tune the oscillator, but otherwise the master clock unit

is functioning normally. If the MCLP is without reference frequencies,

the accuracy of the generated frequencies is poor.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 219 (1095)

7160 BCF/MCLx: LOSS OF PCM-SYNCHRONIZATION

Page 220: Alarm

Instructions

If the alarm appears without a fault in the base station interface

equipment or without disturbances in the PCM connection, change the

MCLP unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

220 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 221: Alarm

96 7161 BCF/MCLx: PCM IS NOT USED TOTUNE MASTER CLOCK

Meaning

The master clock unit (MCLx) does not use the incoming 2M PCM signal

to tune the oscillator of the MCLx. This alarm is possible only in

the MCLP type of master clock unit.

This alarm affects the provided service.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The MCLP auto-tuning can be activated through the HW database.

The field PCM sync: in the MCLx block of the HW database file controls

the use of the PCM in the tuning of the MCLP.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 221 (1095)

7161 BCF/MCLx: PCM IS NOT USED TO TUNE MASTER CLOCK

Page 222: Alarm

The MCLP auto-tuning can also be activated through the Dev. ctrl menu

in the man machine interface (MMI) program.

Cancelling

This alarm is cancelled by activating the MCLP auto-tuning.

222 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 223: Alarm

97 7162 BCF/MCLx: MASTER CLOCK FASTTUNING IN PROGRESS

Meaning

Fast tuning of the master clock unit (MCLx) is in progress.

This alarm affects the provided service.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions from the user.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 223 (1095)

7162 BCF/MCLx: MASTER CLOCK FAST TUNING IN PROGRESS

Page 224: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

224 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 225: Alarm

98 7163 BCF/MCLx: DIFFERENCE INFREQUENCIES BETWEEN PCM ANDMCLx

Meaning

The frequency of the incoming 2M signal differs from the frequency

generated by the master clock unit (MCLx). This alarm is activated

if the frequencies of the PCM and the MCLP deviate more than 0.05 ppm

for longer than five minutes.

This alarm does not affect the provided service.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 225 (1095)

7163 BCF/MCLx: DIFFERENCE IN FREQUENCIES BETWEENPCM AND MCLx

Page 226: Alarm

Instructions

Check the frequency of the incoming 2M PCM signal. If the frequency is

not in order, check the base station interface equipment (BIE) and the

operation of the transmission from or towards the BSC. If the incoming

2M signal and the BIE devices are in order, change the MCLx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

226 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 227: Alarm

99 7164 BCF/MCLx: MASTER CLOCK UNITHARDWARE FAULTY

Meaning

The master clock hardware is faulty.

The fatality of the alarm depends on whether a redundant master clock

unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and it is unable to transmit any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the MCLx unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 227 (1095)

7164 BCF/MCLx: MASTER CLOCK UNIT HARDWARE FAULTY

Page 228: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

228 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 229: Alarm

1007170 BCF/FQHU: MCLx1-FQHU PARITYERROR

Meaning

The frame number from the MCLx1 is missing, or a parity error

has been detected in the frame number data from the MCLx1 unit.

This alarm affects the provided service if only the MCLx1 is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the alarming FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 229 (1095)

7170 BCF/FQHU: MCLx1-FQHU PARITY ERROR

Page 230: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

230 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 231: Alarm

1017171 BCF/FQHU: MCLx2-FQHU PARITYERROR

Meaning

The frame number from the MCLx2 is missing, or a parity error has been

detected in the frame number data from the MCLx2 unit.

This alarm affects the provided service if only the MCLx2 is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the alarming FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 231 (1095)

7171 BCF/FQHU: MCLx2-FQHU PARITY ERROR

Page 232: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

232 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 233: Alarm

1027172 BCF/FQHU: SELF TEST FAILURE

Meaning

The frequency hopping unit (FQHU) has detected a failure during

the selftests, or it has detected a fatal failure during its operation.

This alarm affects the provided service if only one FQHU is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the alarming FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 233 (1095)

7172 BCF/FQHU: SELF TEST FAILURE

Page 234: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

234 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 235: Alarm

1037173 BCF/FQHU: MCLx1-FQHU FRAMECLOCK IS MISSING

Meaning

The frame clock from the MCLx1 is missing.

This alarm affects the provided service if only the MCLx1 is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the alarming FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 235 (1095)

7173 BCF/FQHU: MCLx1-FQHU FRAME CLOCK IS MISSING

Page 236: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

236 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 237: Alarm

1047174 BCF/FQHU: MCLx2-FQHU FRAMECLOCK IS MISSING

Meaning

The frame clock from the MCLx2 is missing.

This alarm affects the provided service if only the MCLx2 is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the alarming FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 237 (1095)

7174 BCF/FQHU: MCLx2-FQHU FRAME CLOCK IS MISSING

Page 238: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

238 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 239: Alarm

1057175 BCF/FQHU: MCLx1-FQHU OCTALBIT CLOCK IS MISSING

Meaning

The octal bit clock from the MCLx1 is missing.

This alarm affects the provided service if only the MCLx1 is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the alarming FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 239 (1095)

7175 BCF/FQHU: MCLx1-FQHU OCTAL BIT CLOCK IS MISSING

Page 240: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

240 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 241: Alarm

1067176 BCF/FQHU: MCLx2-FQHU OCTALBIT CLOCK IS MISSING

Meaning

The octal bit clock from the MCLx2 is missing.

This alarm affects the provided service if only the MCLx2 is used.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm appears, change the alarming FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 241 (1095)

7176 BCF/FQHU: MCLx2-FQHU OCTAL BIT CLOCK IS MISSING

Page 242: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

242 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 243: Alarm

1077177 BCF/FQHU: NO PARAMETERSGIVEN TO UNIT

Meaning

The FQHU has not received initialization parameters from the OMUx.

This alarm affects the provided service.

FQHU

The frequency hopping unit (FQHU) performs baseband frequency

hopping. The FQHU is located in the fast serial link between

the FU and the CU. The fast serial link carries out data transmission

between the FU and the CU. The FQHU connects the FUs to the CUs

according to the frequency hopping law by switching the serial

links.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7177 is not cancelled, replace the FQHU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 243 (1095)

7177 BCF/FQHU: NO PARAMETERS GIVEN TO UNIT

Page 244: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

244 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 245: Alarm

1087190 BTS/RTC: NO PARAMETERSGIVEN TO UNIT

Meaning

The RTC has not received initialization parameters from the OMU.

This alarm affects the provided service. The BTS sector of the

BCF is not working.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7190 is not cancelled, change the RTC.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 245 (1095)

7190 BTS/RTC: NO PARAMETERS GIVEN TO UNIT

Page 246: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

246 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 247: Alarm

1097191 BTS/RTC: ISOLATION FAILURE INCOMBINER INPUTS

Meaning

The RTC has uncorrect channel numbers as parameters, or the RTC

is faulty.

This alarm affects the provided service. The BTS sector of the

BCF is not working.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check that the separation between the channels is at least

3 (> 600kHz). If the channels have been initialized correctly,

try to re-tune the RTC. If the alarm does not disappear,

change the RTC.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 247 (1095)

7191 BTS/RTC: ISOLATION FAILURE IN COMBINER INPUTS

Page 248: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

248 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 249: Alarm

1107192 BTS/RTC: TUNING IN PROCESS

Meaning

The RTC gives this alarm while still tuning the cavity.

This alarm does not affect the provided service. The BTS sector

of the BCF is not working.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions from the user.

Cancelling

Do not cancel the alarm. The system cancels the alarm when the

tuning is complete.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 249 (1095)

7192 BTS/RTC: TUNING IN PROCESS

Page 250: Alarm

250 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 251: Alarm

1117193 TRX/RTC: TUNING FAILED

Meaning

One of the RTC cavities is not tuned to the correct frequency.

This alarm affects the provided service. This TRX is not

working any more.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the alarm 7193 is not cancelled, change the RTC.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 251 (1095)

7193 TRX/RTC: TUNING FAILED

Page 252: Alarm

252 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 253: Alarm

1127194 BTS/RTC:TX ANTENNAPERFORMANCE DEGRADED

Meaning

The standing wave ratio (SWR) at the output of the RTC

exceeds the level 1 value.

This alarm does not affect the provided service.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

The RTC also supervises the condition of the Tx antenna

by monitoring the reflected power from it.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the cable and the connectors between the RTC and the antenna.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 253 (1095)

7194 BTS/RTC:TX ANTENNA PERFORMANCE DEGRADED

Page 254: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

254 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 255: Alarm

1137195 BTS/RTC:TX ANTENNA FAULTY

Meaning

The standing wave ratio (SWR) at the output of the RTC exceeds 3.

This alarm affects the provided service. The BTS of the BCF

is not working.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

The RTC also supervises the condition of the Tx antenna

by monitoring the power reflected from it.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see instructions on Alarm Structure

Instructions

Check the cable and the connections between the RTC and the

antenna. If the cabling and the antenna are in order,

change the RTC.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 255 (1095)

7195 BTS/RTC:TX ANTENNA FAULTY

Page 256: Alarm

Cancelling

To cancel this alarm, use the BTS reset command from MMI or the

lock/unlock command from the BSC MML terminal.

256 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 257: Alarm

1147196 TRX/RTC: CARRIER NOT PRESENT

Meaning

The RTC does not find any carriers during the initialization.

This alarm affects the provided service. This TRX of the BCF

is not working.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

The RTC also supervises the condition of the Tx antenna

by monitoring the reflected power from it.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions from the user.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 257 (1095)

7196 TRX/RTC: CARRIER NOT PRESENT

Page 258: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

258 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 259: Alarm

1157197 TRX/RTC: FILTER OUT OFCONTROL

Meaning

The control of the cavity of the combiner was lost. The tuning of

this cavity is impossible.

This alarm affects the provided service. This TRX is not working

any more.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7197 is not cancelled, change the RTC.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 259 (1095)

7197 TRX/RTC: FILTER OUT OF CONTROL

Page 260: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

260 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 261: Alarm

1167198 BTS/RTC: POWER SUPPLY 1FAULT

Meaning

One of the two +5V power supplies in the RTC is missing.

This alarm does not affect the provided service.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

The RTC also supervises the condition of the TX antenna

by monitoring the power reflected from it.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

RTCB: Localize the faulty RTC power supply by disconnecting

both power supplies one at a time. Change the faulty power

supply to a functioning one.

Other RTC models: Check the incoming voltage.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 261 (1095)

7198 BTS/RTC: POWER SUPPLY 1 FAULT

Page 262: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

262 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 263: Alarm

1177199 BTS/RTC: POWER SUPPLY 2FAULT

Meaning

One of the two +18V power supplies in the RTC is missing.

This alarm does not affect the provided service.

RTC

The remote tune combiner is used to combine and filter

several transmitter outputs of the BTS into one antenna.

The RTC also supervises the condition of the Tx antenna

by monitoring the reflected power from it.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

RTCB: Localize the faulty RTC power supply by disconnecting both power

supplies one at a time. Change the faulty power supply to a functioning

one.

Other RTC models: Check the incoming voltage.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 263 (1095)

7199 BTS/RTC: POWER SUPPLY 2 FAULT

Page 264: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

264 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 265: Alarm

1187200 BCF/EACB: SELF TEST FAILURE

Meaning

An EACB failure in the selftest of the EACB.

This alarm does not affect the provided service.

EACB

The external alarm and control board is used to connect

internal and external alarms of the ON/OFF type.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the EACB unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 265 (1095)

7200 BCF/EACB: SELF TEST FAILURE

Page 266: Alarm

266 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 267: Alarm

1197201 BCF/EACB: NO PARAMETERSGIVEN TO UNIT

Meaning

The EACB has not received initialization parameters from the OMU.

This alarm does not affect the provided service.

EACB

The external alarm and control board is used to connect

internal and external alarms of the ON/OFF type.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If alarm 7201 is not cancelled, change the EACB unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 267 (1095)

7201 BCF/EACB: NO PARAMETERS GIVEN TO UNIT

Page 268: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

268 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 269: Alarm

1207202 BCF/EACB: OMU-EACBCONNECTION FAILURE

Meaning

A failure in the Q1 relay test of the EACB. The EACB has

disconnected itself from the Q1 link and does not respond

to any O&M commands.

This alarm affects the provided service.

EACB

The external alarm and control board is used to connect

internal and external alarms of the ON/OFF type.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the EACB unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 269 (1095)

7202 BCF/EACB: OMU-EACB CONNECTION FAILURE

Page 270: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

270 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 271: Alarm

1217203 BCF/OMU: FAILURE DURING THEINITIALIZATION

Meaning

The initialization of the BTS unit has failed. The alarm is sent to

the BSC at the end of the initialization of the BTS.

This alarm affects the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The faulty unit can be detected by examining the alarm's diagnostic

info field. If the diagnostic info field points to equipment which

is not installed to the BTS, check the contents of the HW database.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 271 (1095)

7203 BCF/OMU: FAILURE DURING THE INITIALIZATION

Page 272: Alarm

If the diagnostic info points to equipment which is installed to the

BTS and if the alarm does not disappear automatically, change the

faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

272 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 273: Alarm

1227204 BCF/MCLx: MASTER CLOCK UNITFAULTY

Meaning

A faulty master clock unit was detected as a result of the correlation

of the alarms.

The fatality of the alarm depends on whether a redundant master clock

unit (MCLx) is installed. If this alarm is active and the redundant

MCLx unit is not installed, the whole cell site is without

synchronization and timing, and this cell site is unable to transmit

any traffic.

MCLx

The master clock unit (MCLx) controls the synchronization and the

timing of the cell site. The clock signals are essential for the

operation of the cell site, and it is possible to double the master

clock unit in order to ensure the redundant control of the

synchronization.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 273 (1095)

7204 BCF/MCLx: MASTER CLOCK UNIT FAULTY

Page 274: Alarm

Instructions

Change the MCLx unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

274 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 275: Alarm

1237205 BCF/OMU: PASSWORD WASCHANGED

Meaning

The alarm is sent to the BSC every time the local password of the

BTS's OMU-MMI has been changed. If the BTS is equipped with the OMUB,

the local password can be used. When the OMU-MMI is started without

the command line switch, which disables the password checking, the

password is requested from the user. The OMU-MMI is activated only

if the OMU accepts the given password.

This is an informative alarm.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 275 (1095)

7205 BCF/OMU: PASSWORD WAS CHANGED

Page 276: Alarm

Instructions

The alarm requires no actions from the user.

Cancelling

This is a transient-type alarm. No cancelling.

276 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 277: Alarm

1247206 BCF/BIE: USER LOGIN

Meaning

The alarm is sent to the BSC every time the user has successfully

logged into BTS with OMU-MMI.

If the BTS is equipped with the OMUB, the local password can be used.

When the OMU-MMI is started without the command line switch, which

disables the password checking, the password is requested from the user.

The OMU-MMI is activated only if the OMU accepts the given password.

This is an informative alarm.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) sub unit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 277 (1095)

7206 BCF/BIE: USER LOGIN

Page 278: Alarm

Instructions

The alarm requires no actions from the user.

Cancelling

This is an event-type alarm. No cancelling.

278 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 279: Alarm

1257207 BCF/OMU: HW DATABASECHANGED

Meaning

The BTS hardware database stored in the flash memory of the operation

and maintenance unit (OMU) has been changed. This alarm is activated

every time the HW database is stored into the flash memory.

This is an informative alarm.

OMU

The operation and maintenance unit (OMU) is responsible for the operation

and maintenance of the BTS. The main functions of the OMU are:

loading of the BTS file packets from the BSC to the BTS, initializing the

BTS, continuous supervision of the BTS equipment, reporting faults to

BSC and testing and operating functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions from the user.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 279 (1095)

7207 BCF/OMU: HW DATABASE CHANGED

Page 280: Alarm

Cancelling

This is a transient-type alarm. No cancelling.

280 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 281: Alarm

1267208 LOCAL BLOCK

Meaning

The alarm is sent to the BSC when the FU, CU ,TRX or BTS object is

locally blocked by a BTS MMI command. Typically, units are blocked

when faulty units are changed at the site. When the local block

command is given, the following operations take place:

- The BTS sends a cancel message to those blocked unit alarms

which have been reported to the BSC before the block command

was given.

- The BTS sends the alarms of the blocking function to the BSC.

- The BTS does not send alarms of the blocked unit to the BSC

any longer.

This alarm can affect the provided service.

The operation and maintenance unit (OMU or BCFA) is responsible for

the operation and maintenance functions of the BTS. The main functions

of the OMU/BCFA are loading of the BTS file packets from the BSC to

the BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 281 (1095)

7208 LOCAL BLOCK

Page 282: Alarm

Instructions

The alarm requires no actions from the user.

Cancelling

The alarm is cancelled when the locally blocked object is locally

deblocked with a BTS MMI command.

282 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 283: Alarm

1277209 BTS/RTC: NO BCCHTRANSMISSION ACTIVATED

Meaning

The carrier of the broadcast control channel (BCCH) has not been

detected by the combiner. The transmission of the BCCH carrier is

faulty. The alarm situation is detected only by the RTC combiner.

This alarm affects the provided service. If this alarm is active,

the cell to which the alarming object belongs is without BCCH carrier

and cannot transmit traffic.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the units are in order, check that the system parameters have

been received from the BSC.

Check the frame units (FU), the carrier units (CU) and the

remote tune combiner (RTC) of this BTS. Change the faulty

unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 283 (1095)

7209 BTS/RTC: NO BCCH TRANSMISSION ACTIVATED

Page 284: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

284 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 285: Alarm

1287210 BCF/OMU: NO RESPONSE FROMTHE UNIT

Meaning

The OMU does not receive a reply to the polling from the token

bus or Q1 bus equipment.

This alarm can affect the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 285 (1095)

7210 BCF/OMU: NO RESPONSE FROM THE UNIT

Page 286: Alarm

Instructions

The unit which does not respond can be detected by examining

the alarm's diagnostic info field. If the diagnostic info field

points to equipment which is not installed to the BTS, check

the contents of the HW database. If the diagnostic info points

to equipment which is installed to the BTS, change the unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

286 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 287: Alarm

1297211 BCF/OMU: REINITIALIZATION OFTHE UNIT FAILED

Meaning

When this alarm is sent to the BSC, the reinitialization of the

faulty unit is stopped. This minimises the appearing of this

alarm and the initilisations of the faulty unit.

This alarm affects the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The faulty unit can be detected by examining the alarm's diagnostic

info field. If the faulty unit is the CU, then the reinitialisation

can be restarted by the TRX lock/unlock command from the BSC, or by

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 287 (1095)

7211 BCF/OMU: REINITIALIZATION OF THE UNIT FAILED

Page 288: Alarm

a local block/deblock command from the OMU-MMI. If the faulty unit

is the RTE, the EACB or the FQHU re-initialisation can be restarted

by resetting the OMU. If the alarm recurs, change the faulty unit.

Cancelling

This alarm is cancelled when the BCF/BTS/TRX lock/unlock

command is given from the BSC.

288 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 289: Alarm

1307212 BCF/OMU: NO HW DATABASE INFLASH MEMORY

Meaning

There is no BTS hardware database in a flash memory of the

Operation and Maintenance Unit (OMU).

This is an information message.

The OMU is responsible for Operation and Maintenance functions

of the BTS. Main functions of the OMU are loading the BTS file

packets from the BSC to the BTS, initialisation of the BTS,

continuous supervision of BTS equipment, reporting of the

faults to BSC, testing and operating functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 289 (1095)

7212 BCF/OMU: NO HW DATABASE IN FLASH MEMORY

Page 290: Alarm

Cancelling

This is a transient type alarm and no cancelling is needed.

290 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 291: Alarm

1317214 BCF/OMU: TBUS INITIALIZATIONERROR

Meaning

The initialization of the OMU's TB controller has failed. The token

bus controller of the OMU is initialized at the initialization phase

of the OMU, or when run time errors of token bus controllers (alarms

7216, 7217, 7219) occur.

The token bus is used between the OMU and the FUs. The OMU and 12 FUs

can be connected to the bus.

This alarm does not affect the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 291 (1095)

7214 BCF/OMU: TBUS INITIALIZATION ERROR

Page 292: Alarm

Instructions

The OMU reinitializes the token bus controller. If the alarm recurs

and the OMU is unable to initialize the FUCs, change the OMU unit.

Cancelling

This is a transient-type alarm. No cancelling.

292 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 293: Alarm

1327215 BCF/OMU: TBUS SELF TESTERROR

Meaning

The selftest of the OMU's token bus controller has failed in the

initialization phase of the OMU.

The token bus is used between the OMU and the FUs. The OMU and

12 FUs can be connected to the bus.

This alarm does not affect the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 293 (1095)

7215 BCF/OMU: TBUS SELF TEST ERROR

Page 294: Alarm

Instructions

The OMU reinitializes the token bus controller. If the alarm

recurs, change the OMU unit.

Cancelling

This is a transient-type alarm. No cancelling.

294 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 295: Alarm

1337216 BCF/OMU: TBUS DRIVER FAULTY

Meaning

The transmitter of the OMU's token bus controller is faulty.

This is a run time error.

The token bus is used between the OMU and the FUs. The OMU and

12 FUs can be connected to the bus.

This alarm does not affect the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The OMU resets the token bus controller. If the alarm appears

continuously, change the OMU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 295 (1095)

7216 BCF/OMU: TBUS DRIVER FAULTY

Page 296: Alarm

Cancelling

This is a transient-type alarm. No cancelling.

296 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 297: Alarm

1347217 BCF/OMU: TBUS MODEM FAULTY

Meaning

The modem of the OMU's token bus controller is faulty.

The token bus is used between the OMU and the FUs. The OMU and

12 FUs can be connected to the bus.

This alarm does not affect the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The OMU resets the token bus controller. If the alarm appears

continuously, change the OMU.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 297 (1095)

7217 BCF/OMU: TBUS MODEM FAULTY

Page 298: Alarm

Cancelling

This is a transient-type alarm. No cancelling.

298 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 299: Alarm

1357218 BCF/OMU: TBUS STARTOPERATING ERROR

Meaning

The initialization of the OMU's token bus controller has failed.

The token bus is used between the OMU and the FUs. The OMU and

12 FUs can be connected to the bus.

This alarm does not affect the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 299 (1095)

7218 BCF/OMU: TBUS START OPERATING ERROR

Page 300: Alarm

Instructions

The OMU resets the token bus controller. If the alarm appears

continuously, change the OMU.

Cancelling

This is a transient-type alarm. No cancelling.

300 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 301: Alarm

1367220 RADIO LOOP OR RX ANTENNATEST EXECUTION

Meaning

The test of the radio loop or the BTS receiver antenna (RAX) has

been started or stopped by using the BTS MMI interface to the BTS,

or from the OMC/BSC (automatic supervision).

The TRX and the time slot employed are indicated to the BSC. The

time slot cannot be used for call functions during the test.

RAX

The RX antenna test can be executed by using the BTS MMI interface

to the BTS, or from the OMC/BSC. An automatic supervision period

can also be defined from the OMC/BSC.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The execution of the radio loop or receiver antenna (RAX) test

is reported to the BSC, which does not use the associated time slot

for call purposes during the testing.

The alarm requires no actions from the user.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 301 (1095)

7220 RADIO LOOP OR RX ANTENNA TEST EXECUTION

Page 302: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

302 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 303: Alarm

1377221 BTS/ RECEIVER ANTENNA TEST,ANTENNA PERFORMANCE DEGRADED

Meaning

As a result of the RX antenna test (RAX), the standing-wave ratio (SWR)

has reached the comparison level 1.

This alarm indicates that the performance of the receiver antenna

has degraded.

RAX

The RX antenna test can be executed by using the OMU-MMI interface

to the BTS, or from the OMC/BSC. An automatic supervision period

can also be defined from the OMC/BSC.

Supplementary information fields

Instructions

The RX antenna of the BTS or the cabling is faulty. The SWR1 alarm

indicates that the BTS cannot 'hear' mobile stations as well as in

normal conditions. However, the cell provides services at some level.

Cancelling

This is a start/cancel type alarm. It is not cancelled even if

the fault situation is over. To cancel the alarm, you must take

the following steps:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 303 (1095)

7221 BTS/ RECEIVER ANTENNA TEST, ANTENNAPERFORMANCE DEGRADED

Page 304: Alarm

- Give the lock/unlock command for each TRX of the alarming cell

(= the BTS in the OMC/BSC).

304 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 305: Alarm

1387222 BTS/ RECEIVER ANTENNA TEST,ANTENNA FAULTY

Meaning

As a result of the RX antenna test (RAX), the standing-wave ratio (SWR)

has reached comparison level 2.

This alarm affects the provided service.

RAX

The RX antenna test can be executed by using the OMU-MMI interface

to the BTS, or from the OMC/BSC. An automatic supervision period

can also be defined from the OMC/BSC.

Supplementary information fields

Instructions

The RX antenna of the BTS or the cabling is faulty. The functioning of

the BTS is probably impeded, so the fault must be corrected at once.

Cancelling

This is a start/cancel type alarm. It is not cancelled even if

the fault situation is over. To cancel the alarm, you must take

the following steps:

- Give the lock/unlock command for each TRX of the alarming cell

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 305 (1095)

7222 BTS/ RECEIVER ANTENNA TEST, ANTENNA FAULTY

Page 306: Alarm

(=the BTS in the OMC/BSC).

NOTE! Locking the BCCH TRX of the cell cuts ongoing calls.

306 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 307: Alarm

1397223 BCF/OMU: FLASH MEMORYERROR

Meaning

Saving to the OMU's flash memory has failed. The flash memory in the

OMU board is used for non-volatile saving of the BTS's SW file packets,

HW database files and passwords.

This alarm affects the provided service.

OMU

The operation and maintenance unit (OMU) is responsible for the

operation and maintenance functions of the BTS. The main functions

of the OMU are loading of the BTS file packets from the BSC to the

BTS, initialization of the BTS, continuous supervision of the BTS

equipment, reporting faults to the BSC and testing and operating

functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 307 (1095)

7223 BCF/OMU: FLASH MEMORY ERROR

Page 308: Alarm

Instructions

If this alarm appears, it is recommended to erase the flash memory

because the contents of the flash memory may be corrupted. The flash

memory is erased by using the BTS's OMU-MMI. After the erasing, reload

the HW database and the necessary programs. If the error recurs, change

the OMU card.

Cancelling

The alarm disappears after resetting the OMU.

308 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 309: Alarm

1407224 TRX SWITCHOVER

Meaning

The OMU has started the transfer of the TRX functions from the primary

TRX to the spare TRX. The TRX is faulty and incapable of performing

the TRX functions. If the TRX switchover succeeds, the state of the

alarming object is enabled after the switchover. During the switchover

procedure, the state of the alarming object is disabled, but if the

state of the object remains disabled, the switchover has failed.

This alarm affects the provided service.

The TRX consists of the carrier unit (CU) and the frame unit (FU).

FU

The frame unit includes all control and baseband functions

related to each speech connection. The frame unit consists

of three digital boards: a frame unit controller and two

identical digital signal processing units.

FUCx

The frame unit controller board, FUCx, handles the signalling

between the base station controller and the mobile station.

The FUCx relays all traffic data between the BIE and the DSPxs

and between the DSPxs and the carrier unit.

DSPx

The digital signalling processing unit, DSPx, performs all

baseband operations for traffic data, for example, encryption,

decryption, coding, decoding and demodulation and combining of

RF signals in the case of antenna diversity.

CU

The carrier unit (CU) is located in the radio interface in

the BTS. The main function of the CU is to convert the baseband

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 309 (1095)

7224 TRX SWITCHOVER

Page 310: Alarm

signal to the radio frequency signal and vice versa. The CU

consists of a transmitter (TXUx) and one or two receivers (RXUAs)

depending on whether diversity is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

A part of the TRX has become faulty so that the fault

interferes with the functioning of the whole TRX. The cause for

the switchover must be found out, and the faults in the TRX

corrected.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

310 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 311: Alarm

1417225 BCF/OMU: BACKUP DEVICEFAULTY

Meaning

The redundant TRX is faulty and the primary TRX is without a backup.

This alarm does not affect the provided service.

The redundant TRX is the backup device of the primary TRX.

When the primary TRX is damaged, the redundant TRX substitutes

the functions of the primary TRX.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the frame unit (FU), the carrier unit (CU) and the remote tune

combiner (RTC) of this TRX and the BTS. Change the faulty unit. If the

units are in order, check the base station interface equipment (BIE).

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 311 (1095)

7225 BCF/OMU: BACKUP DEVICE FAULTY

Page 312: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

312 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 313: Alarm

1427226 BCF/OMU: SW DOWNLOADFAILURE

Meaning

During the startup phase of software downloading one of the BTS units

has failed. The diagnostic info field of the BTS_ALARM message

indicates which BTS unit's software downloading was not successful.

This alarm does not affect the provided service. The unit of the BTS

is not in the running mode.

STM

The site test and measurement unit (STM) is used to test the

operation of the BTS. The possible tests are radio loop tests,

test calls, receiver sensitivity tests and BCCH carrier signal

strength measurements. These tests can be started locally at

the cell site or remotely from the OMC/BSC.

The STM is one of the BTS units which can cause this alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 313 (1095)

7226 BCF/OMU: SW DOWNLOAD FAILURE

Page 314: Alarm

Instructions

Change the alarming unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

314 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 315: Alarm

1437251 BCF/BIE: BLOCKED FROM USE

Meaning

Two units of the BIE have been configured to use the same time slot

internally. To prevent a collision, the time slot has been blocked

from use by one of these units.

This alarm affects the provided services. The BIE is not working

properly and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 315 (1095)

7251 BCF/BIE: BLOCKED FROM USE

Page 316: Alarm

Instructions

Check the time slot configurations of the SMBS and LK2M units of

the BIE. Two or more of them try to reserve the same time slot from

the internal bus of the BIE. At least one unit (not necessarily

the alarming one) may have the wrong settings. If the settings are

correct, replace the alarming unit. Give the correct settings to the

new unit. If the alarm still appears, replace the other SMBSs and LK2Ms

one by one until the alarm disappears. Remember to give the correct

settings for each new unit after inserting them.

Cancelling

Do not cancel the alarm. The system cancels the alarm

after the multiple reservation of a time slot has been removed.

316 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 317: Alarm

1447252 BCF/BIE: LOOP TO INTERFACE

Meaning

A loopback to the interface is used in the testing line section and

the signal cabling. The incoming 2.048 Mbit/s PCM signal has been looped

back to the interface output, and the incoming signal of the BTS BS

interface is replaced by the AIS signal. The normal operation of the

interface is not possible until the loop has been removed.

This alarm affects the provided services. The interface is not working

normally, and the entire cell site is blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 317 (1095)

7252 BCF/BIE: LOOP TO INTERFACE

Page 318: Alarm

Instructions

The loop has been created and can be removed from the Controls

submenu of the service terminal. The same menu can be found in

the BSS Transmission Equipment Handling (TREHAN) MML session of

the BSC, and also in the PC-based transmission management tools

as the DN2-manager and the Macro-STE.

The loop is released automatically after the time-out set for

the Controls settings takes place, or from the service terminal's

Controls submenu. Until then, the normal operation of the

interface is not possible.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

318 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 319: Alarm

1457253 BCF/BIE: LOOP TO EQUIPMENT

Meaning

A loopback to the equipment is used in testing the equipment, the

line section and the signal cabling. The data from the 2.048 Mbit/s

PCM link has been looped back to the BIE before it arrives to the PCM

link. The outgoing signal of the BTS Abis interface is replaced by the

AIS signal.

This alarm affects the provided services. The interface is not working

normally, and the entire cell site is blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 319 (1095)

7253 BCF/BIE: LOOP TO EQUIPMENT

Page 320: Alarm

Instructions

The loop has been created and can be removed from the Controls

submenu of the service terminal. The same menu can be found in

the BSS Transmission Equipment Handling (TREHAN) MML session of

the BSC, and also in the PC-based transmission management tools

as the DN2-manager and the Macro-STE.

The loop is released automatically after the time-out set for

the Controls settings takes place, or from the service terminal's

Controls submenu. Until then, the normal operation of the

interface is not possible.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the loop is released.

320 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 321: Alarm

1467254 BCF/BIE: TEST MODE

Meaning

A hardware test initiated by the operator is running in the

transmission unit.

This alarm affects the provided services. The unit is not working

properly during the test, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 321 (1095)

7254 BCF/BIE: TEST MODE

Page 322: Alarm

Instructions

A test has been started from the Testing submenu of the terminal.

The same menu can be found in the BSS Transmission Equipment

Handling (TREHAN) MML option of the BSC and also in the PC-based

transmission management tools as the DN2-manager and the Macro-STE.

The alarm is active as long as the test is running. Please wait for

the test to finish. No actions are required.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the test has finished.

322 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 323: Alarm

1477255 BCF/BIE: LOSS OF INCOMING 2MSIGNAL

Meaning

The incoming 2.048 Mbit/s PCM signal to the corresponding interface

is lost.

This alarm affects the provided services. The connection to at least

one site is lost, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 323 (1095)

7255 BCF/BIE: LOSS OF INCOMING 2M SIGNAL

Page 324: Alarm

Instructions

It is possible that someone at the BTS cell site or in the vicinity

may have disconnected or errorneously re-connected the terrestrial

transmission cabling coming to the unit from the BSC or another BTS,

or the alarming unit can be faulty. The alarm can also be caused by

an erroneously installed or faulty unit in the far-end, or by a faulty

repeator along the signal path. Check the alarming unit, the far-end,

the cabling and finally the whole signal path.

There may also be other additional transmission equipment at the

cell site, the radio link equipment, for example. Check the operation

of this equipment and the cabling between them and the BIE.

The internal loopbacks of the BIE and other transmission units can be

used to search the fault location. The loops can be created and removed

from the Controls submenu of the service terminal.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

after the 2.048 Mbit/s PCM-signal has recovered.

324 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 325: Alarm

1487256 BCF/BIE: ALARM INDICATIONSIGNAL (AIS) 2M RECEIVED

Meaning

The incoming 2.048 Mbit/s signal is AIS. The AIS signal is detected

if the data is 1111 1111 in every time slot (TS0 - TS31).

This alarm affects the provided services. The unit in the far end is

not working properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 325 (1095)

7256 BCF/BIE: ALARM INDICATION SIGNAL (AIS) 2M RECEIVED

Page 326: Alarm

Instructions

The AIS signal indicates that something is wrong in the far end

and it must checked. Read the alarms of the far end equipment.

This alarm is caused by one of the following reasons:

- a loop to the equipment has been created in the far end;

- the equipment has been reset in the far end;

- the interface is not in use in the far end;

- some other limited fault in the far end unit.

The internal loopbacks of the BIE and other transmission units can

be used to search the fault location. The loops can be created and

removed from the Controls submenu of the service terminal.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

326 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 327: Alarm

1497257 BCF/BIE: LOSS OF FRAMEALIGNMENT

Meaning

The frame alignment of the incoming PCM signal of the corresponding

T1 interface is lost. There are disturbances in the signal path, or

the timing of the network is faulty. The alarm can also be caused by a

fault in the alarming unit or in the far end unit.

This alarm affects the provided services. The unit is not working properly

and the entire cell site may be blocked.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) sub unit number

See alarm instructions.

Instructions

If the frame alignment does not recover by itself in a few

seconds, the signal path, the timing of the network and the units at

both ends of the signal path have to be checked.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 327 (1095)

7257 BCF/BIE: LOSS OF FRAME ALIGNMENT

Page 328: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

328 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 329: Alarm

1507258 BCF/BIE: LOSS OF MULTIFRAMEALIGNMENT

Meaning

The multiframe alignment is lost. The multiframe (MF) is not used

in the far end, or there are disturbances in the signal path.

This alarm affects the provided services. The unit is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 329 (1095)

7258 BCF/BIE: LOSS OF MULTIFRAME ALIGNMENT

Page 330: Alarm

Instructions

In the BTS, the use of this alarm is improbable, because normally

the multiframe (MF) is not in use. There is even no multiframe

setting in the present FW versions of the BIE.

The unit interface settings and the other alarms have to be

checked by means of the commands of the service terminal at

both ends of the PCM signal path. Check also that the FW

versions of BIE are allowed ones.

The multiframe alignment is considered lost when two received

successive multiframe alignment words have been erroneous, or

when only zeros are received from the time slot during one

multiframe.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

330 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 331: Alarm

1517259 BCF/BIE: CRC MULTIFRAMEALIGNMENT LOST

Meaning

The CRC check is not used in the far end, or there are disturbances

in the signal path.

This alarm affects the provided services. The unit is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 331 (1095)

7259 BCF/BIE: CRC MULTIFRAME ALIGNMENT LOST

Page 332: Alarm

Instructions

Check the CRC settings of the unit interface and the PCM signal

path at both ends.

Supposing that the frame alignment has been achieved, the CRC

alignment has occurred if at least two CRC multiframe alignment

words are detected within 8 ms when the interval between two CRC

multiframe alignment words is 2 ms or its multiple. The CRC alignment

word is seen only in those TS0 time slots that do not contain the

frame alignment word.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

332 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 333: Alarm

1527260 BCF/BIE: BIT ERROR RATE (BER) >1E-3

Meaning

The error ratio of the incoming 2.048 Mbit/s PCM signal is worse

than the set threshold value 1E-3.

This alarm affects the provided services. The unit is probably working

properly, but the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 333 (1095)

7260 BCF/BIE: BIT ERROR RATE (BER) > 1E-3

Page 334: Alarm

Instructions

There may be disturbances in the signal path, or the timing of the

network does not work properly. Check these if the alarm does not

disappear after a few seconds. It should be noted in the case of

occasional alarms that fading may sometimes occur, especially when

radio links are used along the signal path.

The alarm can also be caused by a faulty unit (the far end or the

alarming one) or a faulty repeater in the signal path. Check them, too.

The internal loopbacks of the BIE and other transmission units can

be used to search the fault. The loops can be created and

removed from the Controls submenu of the service terminal.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

334 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 335: Alarm

1537261 BCF/BIE: BIT ERROR RATE (BER) >1E-4

Meaning

The error ratio of the incoming 2.048 Mbit/s PCM signal is worse

than the set threshold value 1E-4.

This alarm affects the provided services. The unit is probably working

properly, but the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 335 (1095)

7261 BCF/BIE: BIT ERROR RATE (BER) > 1E-4

Page 336: Alarm

Instructions

There may be disturbances in the signal path, or the timing of the

network does not work properly. Check these if the alarm does not

disappear after a few seconds. It should be noted in the case of

occasional alarms that fading may sometimes occur, especially when

radio links are used along the signal path.

The alarm can also be caused by a faulty unit (the far-end or the

alarming one) or a faulty repeater in the signal path. Check them, too.

The internal loopbacks of the BIE and other transmission units can

be used to search the fault. The loops can be created and

removed from the Controls submenu of the service terminal.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

336 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 337: Alarm

1547262 BCF/BIE: BIT ERROR RATE (BER) >1E-6

Meaning

The error ratio of the incoming 2.048 Mbit/s PCM signal is worse than

the set threshold value 1E-6.

This alarm does not require immediate action. The unit and the entire

cell site are working properly. The bit error rate (BER) is good enough

for normal operation, and the default setting of this alarm is disabled

among the BIE units.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 337 (1095)

7262 BCF/BIE: BIT ERROR RATE (BER) > 1E-6

Page 338: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

There may be disturbances in the signal path, or the timing of the

network does not work properly. Check these if the alarm does not

disappear after a few seconds. It should be noted in the case of

occasional alarms that fading may sometimes occur, especially when

radio links are used along the signal path.

The alarm can also be caused by a faulty unit (the far-end or the

alarming one) or a faulty repeater in the signal path. Check them, too.

The internal loopbacks of the BIE and other transmission units can

be used to search the fault. The loops can be created and

removed from the Controls submenu of the service terminal.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

338 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 339: Alarm

1557263 BCF/BIE: FREQUENCY ERROR

Meaning

The frequency of the synchronizing signal is not correct.

The synchronization frequency going to other BTSs is also incorrect.

None of the external clock sources on timing priority list are valid

and internal clock is taken into use.

This alarm affects the provided service. The network is not working

properly.

The Base Station Interface Equipment (BIE) is the 2 MBit/s PCM

equipment of the BTS. It carries the traffic (speech/data), signalling

and O&M communication towards the BSC or other BTSs. Usually there is

one BIE per cell site. Option for a separate, redundant BIE is also

available.

BIE types: point-to-point (BIE) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 339 (1095)

7263 BCF/BIE: FREQUENCY ERROR

Page 340: Alarm

Instructions

All of the listed external clock sources are missing in

the unit. There may be other alarms activated at the same

time, e.g. 'loss of incoming signal' which can be the source

of this alarm; first check the other alarms.

If the alarm still exists, check the external clock cabling

and signal quality.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when at least one of the listed clock sources has recovered.

340 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 341: Alarm

1567264 BCF/BIE: SYNCHRONIZING FAULT

Meaning

The clock signal to the synchronizing output interface of the DX2M

or the SMHW unit is disconnected automatically due to a fault in the

selected source-RX signal.

The alarm can be active also when the master clock (the internal clock

of the DX2M or the SMHW unit) has been selected to the synchronizing

output connection of the DX2M or the SMHW unit. This is done when all

the clock sources with a higher priority in the syncronization list

are faulty, and the internal clock of the unit is taken into use.

This alarm affects the provided service. The network is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 341 (1095)

7264 BCF/BIE: SYNCHRONIZING FAULT

Page 342: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the other alarms of the unit first.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when at least one of the listed clock sources has recovered.

342 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 343: Alarm

1577265 BCF/BIE: SYNCHRONIZING FAULTIN CLOCK RECOVERY

Meaning

The external 2.048 MHz synchronization input clock signal, which is

provided with a priority on the synchronization list, is missing or

faulty.

This alarm affects the provided service. The unit is working properly,

but the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 MBit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 343 (1095)

7265 BCF/BIE: SYNCHRONIZING FAULT IN CLOCK RECOVERY

Page 344: Alarm

Instructions

Check the synchronizing cabling of the DX2M or the SMHW unit and

the path of the clock signal.

Check the unit which is source for the external synchronization

clock and the other unit alarms.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

344 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 345: Alarm

1587266 BCF/BIE: FAULT IN EQUIPMENT

Meaning

The unit has detected a fault in itself.

This alarm affects the provided services. The unit is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 345 (1095)

7266 BCF/BIE: FAULT IN EQUIPMENT

Page 346: Alarm

Instructions

Reset the alarming unit by removing it from the subrack and then

inserting it back. Wait a moment and check the alarms. If the alarm

still appears, replace the unit with a new one.

Every time a BIE unit has been replaced, the correct settings must be

given to the new unit. In some cases the installation command of the

BIE equipment is also needed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

346 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 347: Alarm

1597267 BCF/BIE: MEMORY FAULT

Meaning

The unit has detected a fault during the RAM, EPROM or EEPROM test.

This alarm affects the provided services. The unit is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 347 (1095)

7267 BCF/BIE: MEMORY FAULT

Page 348: Alarm

Instructions

Reset the alarming unit by removing it from the subrack and then

inserting it back. If the alarming unit is the DB2M or the DX2M,

give the software reset command to the unit (DB2M: 9,6,99,1 or

DX2M: 9,9,2,6,99,1). Wait a moment and then run the tests: RAM-test,

EPROM-test, EEPROM-test and RUNTEST (Testing submenu of the

service terminal). Please note that these tests can generate an

additional alarm (TEST MODE). All the BIE units do not have all

these tests.

The tests should succeed and the BIE should not be alarming if the

unit is in order. If the alarm still appears, replace the unit with

a new one.

Every time a BIE unit has been replaced, the correct settings must be

given to the new unit. In some cases the installation command of the

BIE equipment is also needed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

348 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 349: Alarm

1607268 BIE FAULT IN AIS OSCILLATOR

Meaning

An error has been detected in the AIS oscillator.

Supplementary information fields

Instructions

The alarm requires no actions from the user.

Cancelling

No cancelling.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 349 (1095)

7268 BIE FAULT IN AIS OSCILLATOR

Page 350: Alarm

350 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 351: Alarm

1617269 BCF/BIE: MISSING UNIT

Meaning

The tributary unit of the BIE (DX2M, SMBS or LK2M) has been

disconnected.

This alarm affects the provided services. The BIE is not working

properly, and the entire cell site may be blocked. If the missing

unit is the DX2M or the LK2M, the operation of the network may be

endangered.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 351 (1095)

7269 BCF/BIE: MISSING UNIT

Page 352: Alarm

Instructions

This alarm can be generated during normal operation, for example,

when changing the settings of the BIE. Make sure that the alarm is

automatically cancelled after the service.

If no operations are being done in the alarming BTS, read the

configuration of the BIE unit from the memory of the master unit

(DB2M or SMHW) and check the actual configuration. If they match

and the BIE is still alarming, replace the alarming unit. If they

do not match, check that the site is equipped correctly.

Every time a BIE unit has been replaced or a new unit installed, the

correct settings must be given to the new unit. In some cases the

installation command of the BIE equipment is also needed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

352 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 353: Alarm

1627270 BCF/BIE: FORCED CONTROL ON

Meaning

A forced control, provided with time supervision, has been activated

by the operator by means of a service manual command.

This alarm affects the provided services. It is possible the unit

is not working properly at the present, and the entire cell site may

be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 353 (1095)

7270 BCF/BIE: FORCED CONTROL ON

Page 354: Alarm

Instructions

Some type of forced control has been created and can be removed from

the Controls submenu of the service terminal. The control may be

forced alarm output, fixed data etc. The same menu can be found

in the BSS Transmission Equipment Handling (TREHAN) MML session of

the BSC, and also in the PC-based transmission management tools as

the DN2-manager and the Macro-STE.

The forced control is released automatically after the timeout set

for the Controls settings takes place. Until then the normal operation

of the unit is not possible.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the forced control is removed.

354 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 355: Alarm

1637271 BCF/BIE: INSTALLATION ERROR

Meaning

The BIE is not properly equipped.

The location of each tributary unit of the BIE (DX2M, SMBS, LK2M) has

been stored in the memory of the master unit (DB2M or SMHW). The master

unit has noticed that the actual configuration does not match with the

configuration in the memory. There should be another type of unit

at some location.

This alarm affects the provided services. The BIE is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 355 (1095)

7271 BCF/BIE: INSTALLATION ERROR

Page 356: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Check that the BIE is equipped correctly (the actual configuration).

If it is, try to reinstall the BIE and check that the configuration

in the memory matches with the actual one. If reinstalling does not

work, replace the master unit (DB2M or SMHW). Then install the BIE

again and check that the actual configuration matches with the memory.

If these actions do not give the desired result, replace the tributary

units one by one, install the BIE and check the installation.

If the BIE was not correctly equipped to begin with, correct the

configuration and reinstall the BIE, if needed.

Every time a BIE unit has been replaced or a new unit installed, the

correct settings must be given to the new unit. In some cases the

installation command of the BIE equipment is also needed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the installation has been corrected.

356 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 357: Alarm

1647272 BCF/BIE: FORCED INDICATION

Meaning

The forced control of the maintenance LED is activated.

This is an informative alarm and does not cause any problems

with the unit.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 357 (1095)

7272 BCF/BIE: FORCED INDICATION

Page 358: Alarm

Instructions

One of the service LEDs is commanded to the forced state by

a service terminal command. The LED can be set to be on, off

or to blink, depending on the unit.

The forced indication is released automatically after the timeout

takes place, or by means of a command of the service terminal from

the Controls submenu.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the indication is released.

358 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 359: Alarm

1657273 BCF/BIE: EQUIPMENT RESET

Meaning

The processor of the unit has been reset, for example, when switching

the power on, during a supply voltage drop or some other similar

malfunction.

This alarm affects the provided service. The unit does not work

properly, and the entire cell site is blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 359 (1095)

7273 BCF/BIE: EQUIPMENT RESET

Page 360: Alarm

Instructions

When this alarm is on, the unit has been reset and the alarm will

disappear after a few seconds. If the alarm does not disappear,

the unit is in the reset state and has to be replaced by a new one.

Note that the DX2M unit is in the reset state longer than other

BIE units also during normal maintenance operations.

Sometimes other fault situations also cause the unit reset, for

example, an installation error. Check the other alarms of the site,

too. The reset alarm may disappear when other faults are cleared.

If the unit or the BTS resets itself repeatedly, check the power

supply.

Every time a BIE unit has been replaced, the correct settings must

be given to the new unit. In some cases the installation command

of the BIE equipment is also needed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

360 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 361: Alarm

1667274 BCF/BIE: FAULT IN TRANSMITTER

Meaning

The 2 Mbit/s signal coming from BIE to the converter in the

corresponding interface is faulty or lost.

This alarm affects the provided services. The connection to at least

one site is lost, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

SCUA

The SCUA card contain two independent E1/T1 convertors. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 361 (1095)

7274 BCF/BIE: FAULT IN TRANSMITTER

Page 362: Alarm

3) slot 6) sub unit number

See alarm instructions.

Instructions

The cable between BIE and the converter is probably faulty. It

is also possible that the impedance strappings in BIE are not correct

or the converter or the BIE interface is faulty.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

362 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 363: Alarm

1677275 BCF/BIE: RUN DIAGNOSTICS TEST

Meaning

The unit has detected a fault in itself. Further information is

obtained by a command of the service terminal.

This alarm affects the provided services. The unit may not work

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 363 (1095)

7275 BCF/BIE: RUN DIAGNOSTICS TEST

Page 364: Alarm

Instructions

Activate the runtest by a service terminal command in the Testing

submenu and check the result. If there are no errors, the response

is No runtest error. The error message may be, for example: TBL error

(= branching table error), Int RAM not OK, Ext RAM not OK,

EPROM not OK, EEPROM not OK, etc.

In the case of a runtest error, reset the alarming unit by removing

it from the subrack and then inserting it back. If the alarming unit

is the DB2M or the DX2M, give the software reset command to the unit

(DB2M: 9,6,99,1 or DX2M: 9,9,2,6,99,1). Wait for a moment and then

run the tests: RAM-test, EPROM-test, EEPROM-test and RUNTEST

(the Testing submenu of the service terminal). Please note that these

tests can generate the additional alarm TEST MODE. All the BIE units

do not have all these tests.

The tests should succeed and the BIE should not alarm if the unit

is in order. If the alarm still appears, replace the unit with a

new one.

Every time a BIE unit has been replaced, the correct settings must

be given to the new unit. In some cases the installation command

of the BIE equipment is also needed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

364 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 365: Alarm

1687276 BCF/BIE: ALARM INDICATIONSIGNAL (AIS) RECEIVED ON TIMESLOT16

Meaning

The incoming 2.048 Mbit/s has the AIS signal in the TS16 of the

PCM circuit. The AIS signal is detected if the incoming data is

1111 1111 in the time slot in question.

This alarm affects the provided services. The unit is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 365 (1095)

7276 BCF/BIE: ALARM INDICATION SIGNAL (AIS) RECEIVED ONTIMESLOT 16

Page 366: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

In the BTS, the use of this alarm is improbable, because the

multiframe (MF) is not normally in use.

The unit interface settings and the other alarms have to be

checked by means of the service terminal at both ends of the

PCM link.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

366 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 367: Alarm

1697277 BCF/BIE: FAR-END ALARM 1

Meaning

A far end alarm has been received from the incoming 2.048 Mbit/s

PCM signal. The unit which detects this alarm is the DB2M or the SMHW,

and the fault is in the main signal path.

This alarm affects the provided services. The unit is working properly

in the far end, but the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 367 (1095)

7277 BCF/BIE: FAR-END ALARM 1

Page 368: Alarm

Instructions

The far end unit has detected a fault, e.g.:

- 2M is missing

- 2M AIS

- loss of frame alignment

- the CRC multiframe alignment is lost

- BER > 10E-3.

Check the alarms of the far end site and act according to them.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

368 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 369: Alarm

1707278 BCF/BIE: MULTIFRAME ALARMFROM FAR-END

Meaning

A multiframe alarm from the far end (F0/TS16/B6 is 1) has been

detected from the incoming 2.048 Mbit/s PCM signal.

This alarm affects the provided services. The unit is not working

properly, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 ot 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 369 (1095)

7278 BCF/BIE: MULTIFRAME ALARM FROM FAR-END

Page 370: Alarm

Instructions

The transmitter of the unit does not work properly. Check the settings

of the unit interface settings at both ends of the PCM signal path,

and check that the FW versions of the BIE are allowed.

Reset the unit by removing it from the subrack and then inserting it

back. If the above operations do not help, change the unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

370 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 371: Alarm

1717279 BCF/BIE: FAR END ALARM

Meaning

A far end alarm has been received from the incoming 2.048 Mbit/s

PCM signal. The unit which detects this alarm is the LK2M and

the fault is in the tributary signal path.

This alarm affects the provided services. The unit is working properly

in the far end but the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 371 (1095)

7279 BCF/BIE: FAR END ALARM

Page 372: Alarm

Instructions

The far end unit has detected a fault, e.g.:

- 2M is missing

- 2M AIS

- loss of frame alignment

- the CRC multiframe alignment is lost

- BER > 10E-3.

Check the alarms of the far end site and act according to them.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

372 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 373: Alarm

1727280 BCF/BIE: LOSS OF INCOMING 1.5MSIGNAL

Meaning

The incoming PCM signal to the corresponding T1 interface

of the SCUA is lost.

This alarm affects the provided services. The connection to at least

one site is lost, and the entire cell site may be blocked.

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Someone at the BTS cell site or in the vicinity may have

disconnected or erroneously re-connected the terrestrial

transmission cabling coming to the unit from the BSC or another BTS,

or the alarming unit can be faulty. The alarm can also be caused by

an erroneously installed or faulty unit in the far end, or by a faulty

repeater along the signal path. Check the alarming unit, the far end,

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 373 (1095)

7280 BCF/BIE: LOSS OF INCOMING 1.5M SIGNAL

Page 374: Alarm

the cabling and finally, the whole signal path.

There may also be other transmission equipment at the cell site,

such as radio link equipment. Check the operation of this

equipment and the cabling between them and the SCUA.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

after the PCM signal has recovered.

374 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 375: Alarm

1737281 BCF/BIE: AIS 1.5M

Meaning

The incoming signal to the corresponding T1 interface of the SCUA is

AIS. The AIS signal is detected if the data is 1111 1111 in every

time slot.

This alarm affects the provided services. The unit in the far end is

not working properly, and the entire cell site may be blocked.

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The AIS signal indicates that something is wrong in the far end

and it must checked. Read the alarms of the far end equipment.

This alarm is caused by one of the following reasons:

- a loop to the equipment has been created in the far end

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 375 (1095)

7281 BCF/BIE: AIS 1.5M

Page 376: Alarm

- the equipment has been reset in the far end

- the interface is not in use in the far end

- some other limited fault in the far end unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

376 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 377: Alarm

1747282 BCF/BIE: LOOPED SIGNALRECEIVED

Meaning

A loop is activated in a converter's T1 interface.

This alarm affects the provided services. The connection to at least

one site is lost, and the entire cell site may be blocked.

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions

Instructions

The loop has been created and can be removed with the converter

configuration tool.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 377 (1095)

7282 BCF/BIE: LOOPED SIGNAL RECEIVED

Page 378: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

378 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 379: Alarm

1757283 BCF/BIE: LOSS OF SIGNALLINGFRAME

Meaning

The multiframe alignment is lost. The multiframe (MF) is not used

in the far end, or there are disturbances in the signal path.

This alarm affects the provided services. The unit is not working

properly, and the entire cell site may be blocked.

SCUA

The SCUA card contains two independent E1/T1 convertors. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

In the BTS, the use of this alarm is improbable, because normally

the multiframe (MF) is not in use. There is no multiframe

setting in the present FW versions of the BIE.

The unit interface settings and the other alarms have to be

checked by means of the commands of the service terminal at

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 379 (1095)

7283 BCF/BIE: LOSS OF SIGNALLING FRAME

Page 380: Alarm

both ends of the PCM signal path. Check also that the FW

versions of BIE are allowed ones.

The multiframe alignment is considered lost when two received

successive multiframe alignment words have been erroneous, or

when only zeros are received from the time slot during one

multiframe.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

380 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 381: Alarm

1767284 BCF/BIE: EXCESSIVE ERRORRATE

Meaning

The error ratio of the incoming signal from the corresponding T1

interface of the SCUA is higher than the threshold value 1E-3.

This alarm affects the provided services. The unit is probably working

properly, but the entire cell site may be blocked.

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

There are disturbances in the signal path, or the timing of the

network does not work properly. Check these if the alarm does not

disappear after a few seconds. It should be noted in the case of

occasional alarms that fading may sometimes occur, especially when

radio links are used along the signal path.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 381 (1095)

7284 BCF/BIE: EXCESSIVE ERROR RATE

Page 382: Alarm

The alarm can also be caused by a faulty unit (the far end or the

alarming one) or a faulty repeater in the signal path. Check them, too.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

382 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 383: Alarm

1777285 BCF/BIE: FAULT IN INCOMINGSIGNAL

Meaning

The 2 Mbit/s signal coming from the converter to the BIE in

corresponding interface is faulty but not lost.

This alarm affects the provided services. The connection to at least

one site is lost, and the entire cell site may be blocked.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 383 (1095)

7285 BCF/BIE: FAULT IN INCOMING SIGNAL

Page 384: Alarm

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The cable between BIE and the converter is probably faulty. It

is also possible that the impedance strappings in BIE are not correct,

or the converter or BIE interface is faulty.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

384 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 385: Alarm

1787286 BCF/BIE: CONVERTER RESET

Meaning

The converter is performing a startup self-test. This may be indicative

of a crach and watchdog reset.

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The converter is performing a startup self-test.

If this alarm occurs more than once the converter is faulty.

Replace the converter.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 385 (1095)

7286 BCF/BIE: CONVERTER RESET

Page 386: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the reset procedure is over.

386 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 387: Alarm

1797287 BCF/BIE: CONVERTER FAULT

Meaning

The converter is faulty, or the connection between the BIE

and the converter is faulty.

BIE

The base station interface equipment (BIE) is the 2 Mbit/s PCM

equipment of the BTS. It carries speech and data traffic, signalling

and O&M communication towards the BSC or other BTSs. Usually there

is one BIE per cell site. The option of a separate, redundant BIE

is also available.

BIE types: point-to-point (BIU2M) multidrop (BIUMD)

1 SMHW board 1 DB2M board

1 or 2 SMBS boards 1 DX2M board

0,1 or 2 LK2M boards 1 or 2 SMBS boards

0,1 or 2 LK2M boards

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 387 (1095)

7287 BCF/BIE: CONVERTER FAULT

Page 388: Alarm

Instructions

The converter is faulty, or there are settings that cause the BIE

to receive faulty bits. Check all settings and cables, and

if found faulty, replace the SCUA.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

388 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 389: Alarm

1807288 BCF/BIE: YELLOW ALARM

Meaning

A far end alarm (yellow alarm) has been received from the

corresponding T1 interface of the SCUA.

This alarm affects the provided services. The unit is working properly

in the far end but the entire cell site may be blocked.

SCUA

The SCUA card contains two independent E1/T1 converters. With the

SCUA it is possible to convert 2 Mbit/s PCM to operate in T1 1.544

Mbps standard.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The far end unit has detected a fault, e.g.:

- 1.5M is missing

- AIS

- loss of frame alignment

- the CRC multiframe alignment is lost

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 389 (1095)

7288 BCF/BIE: YELLOW ALARM

Page 390: Alarm

- BER > 10E-3.

Check the alarms of the far end site and act according to them.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

390 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 391: Alarm

1817291 BCF/STM: SELF TEST FAILURE

Meaning

An error is detected in the start-up test of the STM test equipment.

The tests are always carried out at the start-up of the STM.

This alarm does not affect the provided service. The STM tests are

not working any more.

STM

The site test and measurement unit (STM) is used to test the

operation of the BTS. The possible tests are radio loop tests,

test calls, receiver sensitivity tests and BCCH carrier signal

strength measurements. These tests can be started locally at

the cell site or remotely from the OMC/BSC.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 391 (1095)

7291 BCF/STM: SELF TEST FAILURE

Page 392: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

392 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 393: Alarm

1827292 BCF/STM: INTERNAL I/O-BUSFAILURE

Meaning

The internal serial I/O bus of the STM is faulty.

This alarm does not affect the provided service. The STM tests are

not working any more.

STM

The site test and measurement unit (STM) is used to test the

operation of the BTS. The possible tests are radio loop tests,

test calls, receiver sensitivity tests and BCCH carrier signal

strength measurements. These tests can be started locally at

the cell site or remotely from the OMC/BSC.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 393 (1095)

7292 BCF/STM: INTERNAL I/O-BUS FAILURE

Page 394: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

394 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 395: Alarm

1837293 BCF/STM: UNEXPECTEDCOMMAND FROM OMU

Meaning

The STM test equipment has received an unexpected message from

the OMU. The message is impossible for the STM in its current state.

This alarm does not affect the provided service.

STM

The site test and measurement unit (STM) is used to test the

operation of the BTS. The possible tests are radio loop tests,

test calls, receiver sensitivity tests and BCCH carrier signal

strength measurements. These tests can be started locally at

the cell site or remotely from the OMC/BSC.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Carry out the test with the alarming equipment. If it alarms during

the test, change the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 395 (1095)

7293 BCF/STM: UNEXPECTED COMMAND FROM OMU

Page 396: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

396 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 397: Alarm

1847294 BCF/STM: INTERNAL MEMORYTEST FAILURE

Meaning

An error is detected in the memory test of the STM.

This alarm does not affect the provided service. The STM tests are

not working any more.

STM

The site test and measurement unit (STM) is used to test the

operation of the BTS. The possible tests are radio loop tests,

test calls, receiver sensitivity tests and BCCH carrier signal

strength measurements. These tests can be started locally at

the cell site or remotely from the OMC/BSC.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 397 (1095)

7294 BCF/STM: INTERNAL MEMORY TEST FAILURE

Page 398: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

398 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 399: Alarm

1857301 BTS/RXFE: LOW NOISE AMPLIFIER1 FAILURE

Meaning

The low noise amplifier 1 (LNA 1) of the RXFE is broken. The LNA

amplifies the RF signal coming in from the receiver antenna.

This alarm does not affect the provided service.

RXFE is the receiver front end used in the Omni BTS cabinet.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The LNA1 must be changed. If the alarm does not disappear, the

fault may be in the control card (LNAN/LNCD) of the RXFx, which

must be changed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 399 (1095)

7301 BTS/RXFE: LOW NOISE AMPLIFIER 1 FAILURE

Page 400: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

400 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 401: Alarm

1867302 BTS/RXFE: LOW NOISE AMPLIFIER2 FAILURE

Meaning

The low noise amplifier 2 (LNA2) of the RXFE is broken. The LNA

amplifies the RF signal coming in from the receiver antenna.

This alarm does not affect the provided service.

The RXFE is the receiver front end used in the Omni BTS cabinet.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The LNA2 must be changed. If the alarm does not disappear, the

fault may be in the control card (LNAN/LNCD), which must be changed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 401 (1095)

7302 BTS/RXFE: LOW NOISE AMPLIFIER 2 FAILURE

Page 402: Alarm

402 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 403: Alarm

1877303 BTS/RXFE: RELAY 1 IS SET TOPOSITION 1

Meaning

Information on the position of the receiver front end relays.

According to the fault message, the first relay is set to

position 1.

The faults do not cause the alarm at the initialization phase.

During normal operation, this alarm without alarm RELAY ALARM 2

indicates a fault in the controller of the RXFE.

During normal operation, the appearance or disappearance of this

alarm and the RXFE RELAY ALARM 2 indicates that the used LNA has

been changed, and that there is probably a failure in the previously

selected LNA. Alarm LNA ALARM should appear simultaneously.

The RXFE is the receiver front end unit used in the DE 21

Omni cabinet.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 403 (1095)

7303 BTS/RXFE: RELAY 1 IS SET TO POSITION 1

Page 404: Alarm

Instructions

If alarm 7304 has also appeared, no measures are called for.

Otherwise the control unit (LNAN/LNCD) is faulty and

must be changed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

404 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 405: Alarm

1887304 BTS/RXFE: RELAY 2 IS SET TOPOSITION 1

Meaning

Information on the position of the receiver front end relays.

According to the fault message, the first relay is set to

position 1.

The faults do not cause the alarm at the initialization phase.

During normal operation, this alarm without alarm RELAY ALARM 1

indicates a fault in the controller of the RXFE.

During normal operation, the appearance or disappearance of this alarm

and the RXFE RELAY ALARM 1 indicates that the used LNA has been

changed, and that there is probably a failure in the previously

selected LNA. Alarm LNA ALARM should appear simultaneously.

The RXFE is the receiver front end unit used in the DE 21

Omni cabinet.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 405 (1095)

7304 BTS/RXFE: RELAY 2 IS SET TO POSITION 1

Page 406: Alarm

Instructions

If alarm 7303 has also appeared, no measures are called for.

Otherwise the control unit (LNAN/LNCD) is faulty and

must be changed.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

406 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 407: Alarm

1897305 BTS/RMCx: RMCx FAILURE, ONEAMPLIFIER FAULTY

Meaning

The amplifier of the receiver multicoupler (RMCx) is faulty.

The RMCx includes two amplifiers.

This alarm does not affect the provided service.

The RMCx is used to amplify the RF signal coming in from the

receiver antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RMCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 407 (1095)

7305 BTS/RMCx: RMCx FAILURE, ONE AMPLIFIER FAULTY

Page 408: Alarm

408 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 409: Alarm

1907306 BTS/RMCx: RMCx FAILURE, BOTHAMPLIFIERS FAULTY

Meaning

Both amplifiers of the receiver multicoupler (RMCx) are faulty.

If diversity is not used, the cell cannot provide service any longer.

If it is used, service is maintained by using the RF signal coming in

from the diversity antenna (diversity RMCx is used).

The RMCx is used to amplify the RF signal coming in from the receiver

antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the RMCx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 409 (1095)

7306 BTS/RMCx: RMCx FAILURE, BOTH AMPLIFIERS FAULTY

Page 410: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

410 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 411: Alarm

1917307 BTS/RMCx: DIVERSITY RMCxFAILURE, ONE AMPLIFIER FAULTY

Meaning

The amplifier of the diversity receiver multicoupler (RMCx)

is faulty. The RMCx includes two amplifiers.

This alarm does not affect the provided service.

The diversity RMCx is used to amplify the RF signal coming in

from the diversity receiver antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the diversity RMCx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 411 (1095)

7307 BTS/RMCx: DIVERSITY RMCx FAILURE, ONE AMPLIFIERFAULTY

Page 412: Alarm

412 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 413: Alarm

1927308 BTS/RMCx: DIVERSITY RMCxFAILURE, BOTH AMPLIFIERS FAULTY

Meaning

The amplifiers of the diversity receiver multicoupler (RMCx)

are faulty. The RMCx includes two amplifiers.

This alarm does not affect the provided service. The service is

maintained by using the RF signal coming in from the primary antenna,

which has its own RMCx.

The diversity RMCx is used to amplify the RF signal coming in

from the diversity receiver antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The RMCx is faulty, and it must be changed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 413 (1095)

7308 BTS/RMCx: DIVERSITY RMCx FAILURE, BOTH AMPLIFIERSFAULTY

Page 414: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

414 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 415: Alarm

1937309 BTS/TRFE: TOWER FRONT ENDFAILURE

Meaning

The power to the TRFE is fed via the antenna feeder, and this alarm

indicates problems either in the feeding unit inside the BTS rack

(MPFU or TMCx) or in the tower low noise amplifier (TLNA) unit inside

the TRFE, or in the antenna feeder between the TRFE and the BTS.

TRFE

The tower receiver front end (TRFE) is an optional BTS unit which is

located in the antenna mast.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the MPFU or the TMCx. If the alarm is still active, the problem

is in the TRFE located in the mast or in the antenna feeder between

the BTS cabinet and the TRFE. The TACU indicates the faulty TLNA of

the TRFE and it must be changed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 415 (1095)

7309 BTS/TRFE: TOWER FRONT END FAILURE

Page 416: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

416 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 417: Alarm

1947310 BCF/CCFU: CABINET COOLINGFAN UNIT FAILURE

Meaning

A cabinet cooling fan unit (CCFU) failure.

This alarm does not affect the provided service.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the CCFU fuses. If they are OK, change the CCFU.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 417 (1095)

7310 BCF/CCFU: CABINET COOLING FAN UNIT FAILURE

Page 418: Alarm

418 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 419: Alarm

1957311 BCF/SUPx: STATION UNIT POWERSUPPLY MAINS FAILURE

Meaning

The alarm is given in the case of a power failure, or if the input

voltage is below the minimum level in the station unit power supply

(SUPx). This alarm indicates problems in the cell-site power-feed system

to the BTS cabinet.

This alarm does not affect the provided service.

SUPx

The station unit power supply (SUPx) generates operating voltages

for the units located in the subrack of the BTS's station unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the mains voltage. If it is OK, change the SUPx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 419 (1095)

7311 BCF/SUPx: STATION UNIT POWER SUPPLY MAINSFAILURE

Page 420: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

420 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 421: Alarm

1967312 BCF/SUPx: STATION UNIT POWERSUPPLY OUTPUT FAILURE

Meaning

The alarm is given if the voltage of one or several output powers

of the station unit power supply (SUPx) exceeds the accepted range.

This alarm affects the provided service.

SUPx

The station unit power supply (SUPx) generates operating voltages

for the units located in the subrack of the BTS's station unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the SUPx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 421 (1095)

7312 BCF/SUPx: STATION UNIT POWER SUPPLY OUTPUTFAILURE

Page 422: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

422 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 423: Alarm

1977313 BCF/BBUx: BATTERY BACK-UPUNIT MAINS FAILURE

Meaning

The mains has been disconnected and the battery back-up unit (BBUx)

has been taken into use.

This alarm does not affect the provided service.

BBUx

The purpose of the battery back-up unit (BBUx) is to convert

the 230VAC to the -48VDC for the supply units that use the CD

voltage (XUPB, SUPB), the heat exchanger control board (HECA) and

the LTE. During a mains breakdown, the converter switches its

outputs over to the battery voltage. Disappearing of the mains power

does not cause breaks at the converter DC output.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 423 (1095)

7313 BCF/BBUx: BATTERY BACK-UP UNIT MAINS FAILURE

Page 424: Alarm

Instructions

Check if the MAINS switch of the BBUx is in the 'ON' position. If so,

check if the AC voltage is coming in to the connector of the BBSR frame.

If the AC voltage is coming in properly and the unit is still alarming,

change the BBUx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

424 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 425: Alarm

1987314 BCF/BBUx: BATTERY BACK-UPUNIT OUTPUT VOLTAGE FAILURE

Meaning

The alarm is given if the voltage level of the output power of the

battery back-up unit (BBUx) exceeds the accepted range.

This alarm does not affect the provided service.

BBUx

The purpose of the battery back-up unit (BBUx) is to convert

the 230VAC to the -48VDC for the supply units that use the CD

voltage (XUPB, SUPB), the heat exchanger control board (HECA)

and the LTE. During a mains breakdown, the converter switches

its outputs over to the battery voltage.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check if the MAINS switch of the BBUx is in the 'ON' position. If so,

the problem is inside the BBUx. Change the BBUx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 425 (1095)

7314 BCF/BBUx: BATTERY BACK-UP UNIT OUTPUT VOLTAGEFAILURE

Page 426: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

426 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 427: Alarm

1997315 BCF/BBUx: BATTERY FAILURE

Meaning

The alarm is given if the battery voltage of the battery back-up unit

(BBUx) is low or the batteries are not connected.

This alarm does not affect the provided service.

BBUx

The purpose of the battery back-up unit (BBUx) is to convert

the 230VAC to the -48VDC for the supply units that use the CD

voltage (XUPB, SUPB), the heat exchanger control board (HECA)

and the LTE. During a mains breakdown, the converter switches

its outputs over to the battery voltage.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Either the battery voltage is low or the batteries are not connected.

Check the switches (overload protectors) and the connectors on the

battery shelf. If everything is in order, check the batteries.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 427 (1095)

7315 BCF/BBUx: BATTERY FAILURE

Page 428: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

428 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 429: Alarm

2007316 TRX/XUPx: POWER SUPPLY MAINSFAILURE

Meaning

The alarm is given in the case of a power failure, or if the voltage

is below the minimum level in the transceiver (TRX) power supply unit

(XUPx). This alarm indicates problems in the cell site's power feed

system to the BTS cabinet.

This alarm does not affect the provided service.

XUPx

The XUPx generates operating voltages for the units located in the TRX

subrack and to the common busbar inside the BTS. The busbar voltages are

not provided by the station unit power supply (SUPx) and they feed, for

example, the remote tune combiner (RTC or NRTC).

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the mains voltage. If the voltage is OK, change the XUPx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 429 (1095)

7316 TRX/XUPx: POWER SUPPLY MAINS FAILURE

Page 430: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

430 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 431: Alarm

2017317 TRX/XUPx: POWER SUPPLYOUTPUT FAILURE

Meaning

The alarm is given if the voltage of one or several output powers

of the transceiver (TRX) power supply unit (XUPx) exceeds the accepted

range.

This alarm affects the provided service. The associated TRX is blocked

by the BSC.

XUPx

The XUPx generates operating voltages for the units located in the TRX

subrack and to the common busbar inside the BTS. The busbar voltages are

not provided by the station unit power supply (SUPx) and they feed, for

example, the remote tune combiner (RTC or NRTC).

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the XUPx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 431 (1095)

7317 TRX/XUPx: POWER SUPPLY OUTPUT FAILURE

Page 432: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

432 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 433: Alarm

2027318 BTS/ WBCx: TX ANTENNAPERFORMANCE DEGRADED

Meaning

The standing wave ratio (SWR) at the WBCx output exceeds alarm

level 1.

This alarm does not affect the provided service.

WBCx

The wide band combiner (WBCx) is used to combine and filter the maximum

of two transmitter outputs of the BTS into one antenna. The WBCx also

supervises the condition of the TX antenna by monitoring the reflected

power from it.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the cable and the connections between the WBCx and the

antenna.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 433 (1095)

7318 BTS/ WBCx: TX ANTENNA PERFORMANCE DEGRADED

Page 434: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

434 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 435: Alarm

2037319 BTS/WBCx: TX ANTENNA FAULTY

Meaning

The standing wave ratio (SWR) at the WBCx output is over 3.

This alarm affects the provided service. The BTS sector of the BCF

is not working.

WBCx

The wide band combiner (WBCx) is used to combine and filter the maximum

of two transmitter outputs of the BTS into one antenna. The WBCx also

supervises the condition of the TX antenna by monitoring the reflected

power from it.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the cable and the connections between the WBCx and the

antenna. If the cabling and the antenna are in order, change

the WBCx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 435 (1095)

7319 BTS/WBCx: TX ANTENNA FAULTY

Page 436: Alarm

Cancelling

To cancel the alarm, use the BTS reset command from the MMI or the

lock/unlock command from the BSC MML terminal.

436 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 437: Alarm

2047320 BTS/MHPA: MASTHEADPREAMPLIFIER FAULTY

Meaning

The mast-mounted preamplifier is faulty.

This alarm affects the provided service.

MHPA

The masthead amplifier is a receiver front-end device located in the

antenna mast.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the status of the MHPA and the MHPA power LEDs in the RMCA unit.

If the leds are ON, measure the voltage to the MHPA. If the power voltage

is in order, change the MHPA. Otherwise check the condition of the

RMCx unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 437 (1095)

7320 BTS/MHPA: MASTHEAD PREAMPLIFIER FAULTY

Page 438: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

438 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 439: Alarm

2057321 BTS/AFLx: ANTENNA FILTER ANDLOW NOISE AMPLIFIER FAULTY

Meaning

One or both of the amplifiers is faulty in the normal path of the

antenna filter and low noise amplifier unit (AFLx).

If diversity is not used or if the diversity path of the AFLx is

faulty, the cell cannot provide service any more. If diversity is

used, service is maintained by using the RF signal coming in from

the diversity antenna.

AFLx

The AFLx is used to filter and amplify the RF signal coming in from

the receiver antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the AFLx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 439 (1095)

7321 BTS/AFLx: ANTENNA FILTER AND LOW NOISE AMPLIFIERFAULTY

Page 440: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

440 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 441: Alarm

2067322 BTS/AFLx: DIV.ANTENNA FILTERAND LOW NOISE AMPLIFIER FAULTY

Meaning

One or both of the amplifiers is faulty in the diversity path of the

antenna filter and low noise amplifier unit (AFLx).

If the normal path of the AFLx is faulty, the cell cannot provide

service any more. If the normal path is not faulty, service is maintained

by using the RF signal coming in from the normal antenna.

AFLx

The AFLx is used to filter and amplify the RF signal coming in

from the receiver antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Change the AFLx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 441 (1095)

7322 BTS/AFLx: DIV.ANTENNA FILTER AND LOW NOISEAMPLIFIER FAULTY

Page 442: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

442 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 443: Alarm

2077323 BTS/AMUx: TX ANTENNAPERFORMANCE DEGRADED

Meaning

The voltage standing wave ratio at the antenna monitoring unit exceeds

the minor alarm threshold.

This alarm affects the provided service.

AMUx

The antenna monitoring unit (AMUx) supervises the condition of the TX

antenna by monitoring the reflected power from the connection of

the antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Measure the VSWR towards the antenna at the end of the cable which is

connected to the antenna connection of the AMUB. If the VSWR is greater

than the level which has been set to trigger the level 1 alarm, then

check the cabling and connectors of the antenna and the AMUB. If the

alarm does not disappear, then change the AMUB. Do this immediately, as

a faulty monitoring unit affects the traffic directly.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 443 (1095)

7323 BTS/AMUx: TX ANTENNA PERFORMANCE DEGRADED

Page 444: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

444 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 445: Alarm

2087324 BTS/AMUx: TX ANTENNA FAULTY

Meaning

The voltage standing wave ratio at the antenna monitoring unit exceeds

level 2.

This alarm affects the provided service.

AMUx

The antenna monitoring unit (AMUx) supervises the condition of the TX

antenna by monitoring the reflected power from the connection of

the antenna.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Measure the VSWR towards the antenna at the end of the cable which is

connected to the antenna connection of the AMUB. If the VSWR is greater

than the level which has been set to trigger the level 2 alarm, then

check the cabling and connectors of the antenna and the AMUB. If the

alarm does not disappear, then change the AMUB. Do this immediately, as

a faulty monitoring unit affects the traffic directly.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 445 (1095)

7324 BTS/AMUx: TX ANTENNA FAULTY

Page 446: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

446 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 447: Alarm

2097325 DOOR IS OPEN IN REMOTECABINET

Meaning

The door is open in one of the remote cabinets.

This alarm does not affect the provided service.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the doors of the remote cabinets. If they are closed, check

the door switches. If the switches are in order, check that the cabling

of the external alarm and the control board are in order and that the

optical links are functioning.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 447 (1095)

7325 DOOR IS OPEN IN REMOTE CABINET

Page 448: Alarm

448 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 449: Alarm

2107326 HEAT EXCHANGER FAULTY INREMOTE CABINET

Meaning

There is a fault in the heat exchanger in one of the remote cabinets.

This alarm does not affect the provided service.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the fans of the heat exchangers of the remote cabinet. If the

fans are operating, then check that the cabling to the external alarm

and the control board is in order and that the optical link is

functioning.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 449 (1095)

7326 HEAT EXCHANGER FAULTY IN REMOTE CABINET

Page 450: Alarm

450 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 451: Alarm

2117327 HEAT EXCHANGER FAULTY INLOCAL CABINET

Meaning

There is a fault in the heat exchanger in one of the local cabinets.

This alarm does not affect the provided service.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the fans of the heat exchangers of the local cabinet.

If the fans are operating, there is a fault in the alarm circuit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 451 (1095)

7327 HEAT EXCHANGER FAULTY IN LOCAL CABINET

Page 452: Alarm

452 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 453: Alarm

2127328 OPTICAL LINK TO REMOTE HEADFAULTY

Meaning

There is problem in the optical link to the remote head.

This alarm affects the provided service.

The optical link connects the local and the remote head cabinets.

All signals between the cabinets are carried via this link.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the optical link alarms. If also the RHF_AL alarm is on, there

is a fault in one or both of the optical links to the remote head.

If the RHF_AL alarm is not on, there is a fault in the link towards

the remote head only. Do this immediately, as a faulty optical link

of the remote head affects the traffic directly.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 453 (1095)

7328 OPTICAL LINK TO REMOTE HEAD FAULTY

Page 454: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

454 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 455: Alarm

2137329 OPTICAL LINK FROM REMOTEHEAD FAULTY

Meaning

There is a problem in the optical link to the remote head.

This alarm affects the provided service.

The optical link connects the local and the remote head cabinets.

All signals between the cabinets are carried via this link.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the optical link alarms. If also the RHC_AL alarm is on, there

is a fault in one or both of the optical links to the remote head.

If the RHC_AL alarm is not on, there is a fault in the link towards

the remote head only. Do this immediately, as a faulty optical link

of the remote head affects the traffic directly.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 455 (1095)

7329 OPTICAL LINK FROM REMOTE HEAD FAULTY

Page 456: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

456 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 457: Alarm

2147330 OVER TEMPERATURE IN REMOTEHEAD

Meaning

The temperature in one of the remote head cabinets has exceeded

the 60 C threshold.

This alarm does not affect the provided service.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the ventilation slots and the heat exchanger in the remote head.

If the heat exchanger is functioning, check that the cabling to the

external alarm and control boards is in order and that the optical

links are functioning.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 457 (1095)

7330 OVER TEMPERATURE IN REMOTE HEAD

Page 458: Alarm

458 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 459: Alarm

2157331 TEMPERATURE CONTROLLINGDEVICE FAULTY

Meaning

The air conditioning or TECA unit is faulty or without power supply.

Due to this fault, the cabinet internal temperature can exceed the

operational limits.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the external damages and air paths of the cabinet and air

conditioner. Check the fuse of TECA unit. Check the power supply

and alarm cabling to air conditioner/ TECA unit.

If power supply and the cabling is in order and air paths are clean,

the air conditioner/TECA unit is faulty. Repair/change the air

conditioner/TECA unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 459 (1095)

7331 TEMPERATURE CONTROLLING DEVICE FAULTY

Page 460: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

460 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 461: Alarm

2167332 BCF:HEAT EXCHANGER POWERSUPPLY OUTPUT FAILURE

Meaning

The alarm is given if the output voltage (nominal 48VDC) of

the heat exchanger power supply unit (HEPC) exceeds the

accepted range.

The alarm is activated if:

1. the input power switch on the front panel is in the zero

position (OFF);

2. the input voltage (nominal 230VAC) exceeds the specified range;

3. the load exceeds the specified range (there is, for example,

a short circuit in the load);

4. the alarm line is not connected, or the HEPC unit is faulty.

HEPC

The heat exchanger power supply unit (HEPC) gives the operating voltage

for the heat exchanger located in the mini outdoor basic cabinet

(HEP1: cabinet 11, shelf 5, slot 1) or the mini outdoor extension cabinet

(HEP2: cabinet 21, shelf 8, slot 1). The HEPC is needed only when

AC supply is used.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 461 (1095)

7332 BCF:HEAT EXCHANGER POWER SUPPLY OUTPUTFAILURE

Page 462: Alarm

Instructions

If the HEPC is faulty, change the unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

462 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 463: Alarm

2177401 EXTERNAL AL 1

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 1.

For more information on this alarm in case of Nokia Flexi EDGE BTS,

see "Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE

BTS Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 463 (1095)

7401 EXTERNAL AL 1

Page 464: Alarm

464 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 465: Alarm

2187402 EXTERNAL AL 2

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 2.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 465 (1095)

7402 EXTERNAL AL 2

Page 466: Alarm

466 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 467: Alarm

2197403 EXTERNAL AL 3

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 3.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 467 (1095)

7403 EXTERNAL AL 3

Page 468: Alarm

468 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 469: Alarm

2207404 EXTERNAL AL 4

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 4.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 469 (1095)

7404 EXTERNAL AL 4

Page 470: Alarm

470 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 471: Alarm

2217405 EXTERNAL AL 5

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 5.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 471 (1095)

7405 EXTERNAL AL 5

Page 472: Alarm

472 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 473: Alarm

2227406 EXTERNAL AL 6

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 6.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 473 (1095)

7406 EXTERNAL AL 6

Page 474: Alarm

474 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 475: Alarm

2237407 EXTERNAL AL 7

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 7.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 475 (1095)

7407 EXTERNAL AL 7

Page 476: Alarm

476 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 477: Alarm

2247408 EXTERNAL AL 8

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 8.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 477 (1095)

7408 EXTERNAL AL 8

Page 478: Alarm

478 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 479: Alarm

2257409 EXTERNAL AL 9

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 9.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 479 (1095)

7409 EXTERNAL AL 9

Page 480: Alarm

480 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 481: Alarm

2267410 EXTERNAL AL 10

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 10.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 481 (1095)

7410 EXTERNAL AL 10

Page 482: Alarm

482 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 483: Alarm

2277411 EXTERNAL AL 11

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 11.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 483 (1095)

7411 EXTERNAL AL 11

Page 484: Alarm

484 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 485: Alarm

2287412 EXTERNAL AL 12

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 12.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 485 (1095)

7412 EXTERNAL AL 12

Page 486: Alarm

486 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 487: Alarm

2297413 EXTERNAL AL 13

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 13.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 487 (1095)

7413 EXTERNAL AL 13

Page 488: Alarm

488 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 489: Alarm

2307414 EXTERNAL AL 14

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 14.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 489 (1095)

7414 EXTERNAL AL 14

Page 490: Alarm

490 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 491: Alarm

2317415 EXTERNAL AL 15

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 15.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 491 (1095)

7415 EXTERNAL AL 15

Page 492: Alarm

492 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 493: Alarm

2327416 EXTERNAL AL 16

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 16.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 493 (1095)

7416 EXTERNAL AL 16

Page 494: Alarm

494 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 495: Alarm

2337417 EXTERNAL AL 17

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 17.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 495 (1095)

7417 EXTERNAL AL 17

Page 496: Alarm

496 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 497: Alarm

2347418 EXTERNAL AL 18

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 18.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 497 (1095)

7418 EXTERNAL AL 18

Page 498: Alarm

498 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 499: Alarm

2357419 EXTERNAL AL 19

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 19.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 499 (1095)

7419 EXTERNAL AL 19

Page 500: Alarm

500 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 501: Alarm

2367420 EXTERNAL AL 20

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 20.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 501 (1095)

7420 EXTERNAL AL 20

Page 502: Alarm

502 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 503: Alarm

2377421 EXTERNAL AL 21

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 21.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 503 (1095)

7421 EXTERNAL AL 21

Page 504: Alarm

504 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 505: Alarm

2387422 EXTERNAL AL 22

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 22.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 505 (1095)

7422 EXTERNAL AL 22

Page 506: Alarm

506 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 507: Alarm

2397423 EXTERNAL AL 23

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 23.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 507 (1095)

7423 EXTERNAL AL 23

Page 508: Alarm

508 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 509: Alarm

2407424 EXTERNAL AL 24

Meaning

This is an external user-defined alarm.

For instructions on how to define the alarm for Nokia MetroSite BTS,

Nokia UltraSite BTS, or Nokia Flexi EDGE BTS, see "Adding an external

input and output text (Nokia MetroSite, Nokia UltraSite, and Nokia

Flexi EDGE only)".

For other site types, you should define the alarm in a HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 24.

For more information on this alarm in case of Nokia Flexi EDGE BTS, see

"Trouble Management of Nokia Flexi EDGE BTS" in Nokia Flexi EDGE BTS

Product Documentation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 509 (1095)

7424 EXTERNAL AL 24

Page 510: Alarm

510 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 511: Alarm

2417425 EXTERNAL AL 25

Meaning

This is an external user-defined alarm. The alarm is defined by

the user in an HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as an external

alarm no. 25.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 511 (1095)

7425 EXTERNAL AL 25

Page 512: Alarm

512 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 513: Alarm

2427426 EXTERNAL AL 26

Meaning

This is an external user-defined alarm. The alarm is defined

by the user in an HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 26.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 513 (1095)

7426 EXTERNAL AL 26

Page 514: Alarm

514 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 515: Alarm

2437427 EXTERNAL AL 27

Meaning

This is an external user-defined alarm. The alarm is defined by the

user in an HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 27.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 515 (1095)

7427 EXTERNAL AL 27

Page 516: Alarm

516 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 517: Alarm

2447428 EXTERNAL AL 28

Meaning

This is an external user-defined alarm. The alarm is defined by

the user in an HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 28.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 517 (1095)

7428 EXTERNAL AL 28

Page 518: Alarm

518 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 519: Alarm

2457429 EXTERNAL AL 29

Meaning

This is an external user-defined alarm. The alarm is defined by the

user in an HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 29.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 519 (1095)

7429 EXTERNAL AL 29

Page 520: Alarm

520 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 521: Alarm

2467430 EXTERNAL AL 30

Meaning

This is an external user-defined alarm. The alarm is defined by the

user in an HW database.

Supplementary information fields

Instructions

The operation depends on what kind of alarm is used as external

alarm no. 30.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 521 (1095)

7430 EXTERNAL AL 30

Page 522: Alarm

522 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 523: Alarm

2477500 BCF/ : CABINET TEMPERATUREALARM

Meaning

The temperature in the outdoor cabinet is too high.

The temperature in the All Climate (Street Level) Outdoor Cabinet is

too high or too low.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the external damages and air paths of the cabinet and heat

exchanger/air conditioner. Check alarm cabling to temperature sensors.

If the alarm cabling is in order and air paths are clean, the heat

exchanger/air conditioner is faulty. Repair/change the heat

exchanger/air conditioner.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 523 (1095)

7500 BCF/ : CABINET TEMPERATURE ALARM

Page 524: Alarm

524 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 525: Alarm

2487501 BCF/ CABINET DOOR OPEN

Meaning

The door of the outdoor cabinet is open.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the cabinet door. If it is closed, check the door switch. If the

switch is OK, the alarm circuit to the EACB is faulty.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 525 (1095)

7501 BCF/ CABINET DOOR OPEN

Page 526: Alarm

526 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 527: Alarm

2497502 BCF/ : CABINET TEMPERATURECONTROL SYSTEM FAILURE

Meaning

A fault in the heat exchanger or in the air conditioner depending

on which one is used in the cabinet.

This alarm does not affect the provided service.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

With GSM Street Level Outdoor Cabinet

Check the external damages and air paths of the cabinet.

Check the fuse in the front panel of the HECA. If the fuse is in

order, one or both fans are out of order. If the fans are working,

the cabling of the alarm circuit or the measurement sensor

are out of order.

With GSM Roof Top Cabinets

DCS Mini Outdoor Cabinet

DCS Remote Head Cabinet

Check the external damages and air paths of the cabinet.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 527 (1095)

7502 BCF/ : CABINET TEMPERATURE CONTROL SYSTEMFAILURE

Page 528: Alarm

Check the power supply and alarm cabling to the heat

exchanger/air conditioner. Check the power supply to the heat

exchanger/air conditioner. If power supply and the cabling is

in order, the heat exchanger/air conditioner is faulty. Change

the heat exchanger/air conditioner.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

528 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 529: Alarm

2507503 FAULT IN DBUS INTERFACE OFTRX

Meaning

The TRX processor is not able to communicate with the D-bus.

This is a fatal alarm. The TRX is blocked.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 529 (1095)

7503 FAULT IN DBUS INTERFACE OF TRX

Page 530: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

530 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 531: Alarm

2517504 FAULT IN ABIS INTERFACE OF TRX

Meaning

A fault in the CHDSP-BSIA loop. The contents and/or size of the looped

TRAU frame are incorrect.

This is a fatal alarm. The loop test is re-executed, and if it fails,

the TRX is blocked.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 531 (1095)

7504 FAULT IN ABIS INTERFACE OF TRX

Page 532: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

532 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 533: Alarm

2527505 FAULT IN TRX CONTROLLER

Meaning

The main processor of the TRX is not able to operate properly.

This is a fatal alarm. The TRX is blocked.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 533 (1095)

7505 FAULT IN TRX CONTROLLER

Page 534: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

534 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 535: Alarm

2537506 FAULT IN TRX SERVICEINTERFACE

Meaning

A failure in the loop test of the RS-232 service interface.

The TRX is unable to communicate with the service interface.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 535 (1095)

7506 FAULT IN TRX SERVICE INTERFACE

Page 536: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

536 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 537: Alarm

2547507 INTERNAL COMMUNICATIONFAILURE IN TRX

Meaning

The RF modules of the TRX are not available.

This is a fatal alarm. The RF module is not able to report

any alarms and the status of the RF module is unknown.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 537 (1095)

7507 INTERNAL COMMUNICATION FAILURE IN TRX

Page 538: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

538 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 539: Alarm

2557508 RADIO TIMESLOT FAILURE IN TRX

Meaning

An error situation has been detected in some EQDSP of the TRX.

All EQDSP timeslot faults are indicated with this alarm.

This is a fatal alarm.

EQDSP

The equalizer digital signal processors (EQDSP) are in charge of

the equalization functions within the TRX receiver. The equalization

functions include DC-offset cancellation, receiver signal level

calculation, timing advance calculation,frequency error compensation

and detection and diversity combining.

TRX

The TRX has four main tasks. It is the radio interface of the base

station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 539 (1095)

7508 RADIO TIMESLOT FAILURE IN TRX

Page 540: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

540 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 541: Alarm

2567509 RADIO TIMESLOT FAILURE IN TRX

Meaning

An error situation has been detected in some CHDSP of the TRX.

All CHDSP timeslot alarms are mapped to this alarm.

This is a fatal alarm.

CHDSP

The digital signal processor for the channel coding and decoding

(CHDSP) is in charge of the coding, decoding, encryption and

decryption of the traffic between the Abis and radio interfaces.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 541 (1095)

7509 RADIO TIMESLOT FAILURE IN TRX

Page 542: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

542 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 543: Alarm

2577510 ABIS TESTLOOP FAILURE IN TRX

Meaning

A fault has been detected in the TRX - TRU loop test.

If alarms 7516 and 7517 are also active, the TRX is probably faulty.

Otherwise the TRU is probably faulty.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Checked whether the TRX has also issued also alarms 7516 and 7517.

If not, then the TRU is probably faulty. If both alarms are on, then

the TRX is faulty. Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 543 (1095)

7510 ABIS TESTLOOP FAILURE IN TRX

Page 544: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

544 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 545: Alarm

2587511 RADIO TESTLOOP FAILURE IN TRX

Meaning

A fault in the TRX loop test.

This is a non-fatal/fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 545 (1095)

7511 RADIO TESTLOOP FAILURE IN TRX

Page 546: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

546 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 547: Alarm

2597512 FRAME CLOCK INTERFACEFAILURE

Meaning

The TRX FCLK clock is broken.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 547 (1095)

7512 FRAME CLOCK INTERFACE FAILURE

Page 548: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

548 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 549: Alarm

2607513 FRAME CLOCK IS MISSING IN TRX

Meaning

The TRX has detected a failure in the FCLK.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 549 (1095)

7513 FRAME CLOCK IS MISSING IN TRX

Page 550: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

550 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 551: Alarm

2617514 13 MHZ CLOCK IS MISSING IN TRX

Meaning

The TRX has detected a failure in the 13 MHz clock.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 551 (1095)

7514 13 MHZ CLOCK IS MISSING IN TRX

Page 552: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

552 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 553: Alarm

2627515 FAILURE IN CONNECTION TOFREQUENCY HOPPING

Meaning

The DSP is unable to send data to the F-bus.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 553 (1095)

7515 FAILURE IN CONNECTION TO FREQUENCY HOPPING

Page 554: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

554 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 555: Alarm

2637516 DATA TRANSFER FAILURE INFREQUENCY HOPPING DETECTED BYTRX

Meaning

The DSP has received corrupted data from the F-bus.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 555 (1095)

7516 DATA TRANSFER FAILURE IN FREQUENCY HOPPINGDETECTED BY TRX

Page 556: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

556 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 557: Alarm

2647517 FAILURE IN LOCAL TEST DATA INFREQUENCY HOPPING

Meaning

An error in the F-bus looped data.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 557 (1095)

7517 FAILURE IN LOCAL TEST DATA IN FREQUENCY HOPPING

Page 558: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

558 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 559: Alarm

2657518 FAILURE IN REMOTE TEST DATAIN FREQUENCY HOPPING

Meaning

The TRX has detected an error in the looped data on the F-bus.

The sender of the alarm is remote the TRX (the hopping algorithm

may be illegal).

This is an informative notification.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Reset and reinitialise the BCF.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 559 (1095)

7518 FAILURE IN REMOTE TEST DATA IN FREQUENCYHOPPING

Page 560: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

560 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 561: Alarm

2667519 FAULT IN POWER CONTROLMEMORY

Meaning

The TRX flash memory checksum power control invalid. The stored

power control values are corrupted.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 561 (1095)

7519 FAULT IN POWER CONTROL MEMORY

Page 562: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

562 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 563: Alarm

2677520 FAULT IN WATCH-DOG OF TRX

Meaning

The watchdog is unable to reset the TRX.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the setting of the watch-dog jumpper on the board.

If the watch-dog is enabled then replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 563 (1095)

7520 FAULT IN WATCH-DOG OF TRX

Page 564: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

564 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 565: Alarm

2687521 TRX TEMPERATURE INCREASED

Meaning

The temperature inside the TRX unit is higher than 60 C.

Cooling is necessary.

This is an informative notification.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 565 (1095)

7521 TRX TEMPERATURE INCREASED

Page 566: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

566 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 567: Alarm

2697522 TRX TEMPERATURE HIGH

Meaning

The temperature inside the TRX is higher than 75 C.The TRX is running

too hot. Either the outside temperature has increased and the fans

cannot compensate it or the TRX is broken.

This alarm is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 567 (1095)

7522 TRX TEMPERATURE HIGH

Page 568: Alarm

Instructions

Check the fan units in the same cabinet and the air-conditioning at

the cell site. To reduce the thermal radiation, lower the transmission

level of the alarming TRX. If the temperature returns to normal, this

alarm disappears. If the temperature keeps increasing, the TRX issues

a fatal alarm, after which it must be blocked off.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

568 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 569: Alarm

2707523 TRX TEMPERATUREDANGEROUSLY HIGH

Meaning

The temperature inside the TRX unit is higher than 80 C.

The TX power must be switched off to prevent damage to the

components.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 569 (1095)

7523 TRX TEMPERATURE DANGEROUSLY HIGH

Page 570: Alarm

Instructions

The TRX starts functioning normally when the temperature has gone down.

Check the cabinet fans and the air-conditioning at the cell site. If the

temperature of the TRX is normal and this alarm is still on, change

the the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

570 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 571: Alarm

2717524 TX FREQUENCY TUNER OUT OFORDER

Meaning

One of the TX phase lock synthesisers (PLL1 or PLL2) is out of order.

In the case of the PrimeSite base station, this alarm is non-fatal if

the hopping mode is non-hopping, otherwise this alarm is fatal.

In other base stations the TRX is still operative if the mode is

non-hopping mode or baseband-hopping mode. If the other synthesiser

is not locked either, this alarm is fatal and the TRX must be blocked.

In the case of synthesiser-hopping mode, this alarm is always fatal.

This is a non-fatal/fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 571 (1095)

7524 TX FREQUENCY TUNER OUT OF ORDER

Page 572: Alarm

Instructions

The synthesiser which is intended to be used in the

synthesiser-hopping case is not working properly. Either

the reference clock is disturbed, or the TRX is broken.

Check the corresponding clocks and their cables. If the

clocks and cables are in order, change the TRX.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

572 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 573: Alarm

2727525 TX MAIN FREQUENCY TUNER OUTOF ORDER

Meaning

The TRX reference frequency synthesizer is not locked.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 573 (1095)

7525 TX MAIN FREQUENCY TUNER OUT OF ORDER

Page 574: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

574 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 575: Alarm

2737526 RX FREQUENCY TUNER OUT OFORDER

Meaning

One of the RX phase lock synthesizers is out of order.

In the case of the PrimeSite base station, this alarm is non-fatal if

the hopping mode is non-hopping, otherwise this alarm is fatal.

In other base stations the TRX is still operative if the mode is

non-hopping mode or baseband-hopping mode. If the other synthesizer

is not locked either, this alarm is fatal and the TRX must be blocked.

In the case of synthesizer hopping mode, this alarm is always fatal.

This is a non-fatal/fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 575 (1095)

7526 RX FREQUENCY TUNER OUT OF ORDER

Page 576: Alarm

Instructions

Either the reference clock is disturbed, or the TRX is broken.

Check the corresponding clocks and their cables. If the clocks

and cables are in order, change the TRX.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

576 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 577: Alarm

2747527 RX MAIN FREQUENCY TUNER OUTOF ORDER

Meaning

The RX reference frequency synthesizer is not locked (PLL3).

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 577 (1095)

7527 RX MAIN FREQUENCY TUNER OUT OF ORDER

Page 578: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

578 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 579: Alarm

2757528 TEST LOOP TUNING OUT OFORDER

Meaning

The TRX loop synthesizer is not locked and may be faulty.

This alarm is non fatal.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 579 (1095)

7528 TEST LOOP TUNING OUT OF ORDER

Page 580: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

580 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 581: Alarm

2767529 RECEIVER FAULT

Meaning

This alarm indicates a failure in one of the RX module synthesisers.

The main receiver branch or the diversity synthesiser is out of order.

The unit is operational if one of the receivers still operates.

(This also depends on the antenna configuration, namely whether

diversity is connected or not.)

This is a non-fatal/fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 581 (1095)

7529 RECEIVER FAULT

Page 582: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

582 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 583: Alarm

2777530 TX OUTPUT POWER LEVELDECREASED

Meaning

The TX power level has decreased from the given value because

of an HW-fault in the RFU.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 583 (1095)

7530 TX OUTPUT POWER LEVEL DECREASED

Page 584: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

584 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 585: Alarm

2787531 TX OUTPUT POWER LOST

Meaning

This alarm is generated by the TRX software if the measurement

of the transmitter power indicates a power-off although the transmission

should be active.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 585 (1095)

7531 TX OUTPUT POWER LOST

Page 586: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

586 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 587: Alarm

2797532 TRANSMITTER OUT OF CONTROL

Meaning

This alarm is generated by the TRX software if the measurement of

the transmitter power indicates power-on although the transmission

should be off.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 587 (1095)

7532 TRANSMITTER OUT OF CONTROL

Page 588: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

588 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 589: Alarm

2807533 TX ANTENNA OR COMBINERCONNECTION FAULTY

Meaning

This alarm indicates that the SWR level in the TRX TX interface

is too high. It is caused by the cabling or the combiner fault.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the cabling and combiner first. If everything is in order

then replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 589 (1095)

7533 TX ANTENNA OR COMBINER CONNECTION FAULTY

Page 590: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

590 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 591: Alarm

2817535 RECEIVING FAULT IN BASEBANDMODULE

Meaning

If diversity is used, both EQDSP receiving paths are faulty.

If diversity is not used, the only path is faulty.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 591 (1095)

7535 RECEIVING FAULT IN BASEBAND MODULE

Page 592: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

592 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 593: Alarm

2827536 FAILURE IN MAIN RECEIVING PATHOF BASEBAND MODULE

Meaning

The normal EQDSP receiving path is faulty.

NOTE: This alarm can occur only when diversity is used. Otherwise

alarm 7535 is issued.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 593 (1095)

7536 FAILURE IN MAIN RECEIVING PATH OF BASEBANDMODULE

Page 594: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

594 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 595: Alarm

2837537 FAILURE IN DIVERSITY RECEIVINGPATH OF BASEBAND MODULE

Meaning

The EQDSP diversity path is faulty.

NOTE: This alarm can occur only when diversity is used.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 595 (1095)

7537 FAILURE IN DIVERSITY RECEIVING PATH OF BASEBANDMODULE

Page 596: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

596 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 597: Alarm

2847538 SIGNALLING ERROR IN ABISINTERFACE

Meaning

A failure at the TRX in the telecommunication signalling message

transfer.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the telecom signalling. If everyting is

in order and this alarm is still active replace the TRX unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 597 (1095)

7538 SIGNALLING ERROR IN ABIS INTERFACE

Page 598: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

598 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 599: Alarm

2857539 SIGNALLING ERROR IN DBUS

Meaning

A failure at the TRX in the internal D-bus message transfer.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 599 (1095)

7539 SIGNALLING ERROR IN DBUS

Page 600: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

600 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 601: Alarm

2867540 AIR INTERFACE DUMB

Meaning

The BCCH TRX has reported that the TS 0 is not working.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 601 (1095)

7540 AIR INTERFACE DUMB

Page 602: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

602 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 603: Alarm

2877541 PART OF AIR TIME SLOTS DUMB

Meaning

The CH/EQ DSP or the CH/EQ DSPs are not working.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 603 (1095)

7541 PART OF AIR TIME SLOTS DUMB

Page 604: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

604 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 605: Alarm

2887542 LAPD LINK OFF

Meaning

The LAPD link is released.

This is an informative notification.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 605 (1095)

7542 LAPD LINK OFF

Page 606: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

606 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 607: Alarm

2897543 FRAME NUMBER DISCREPANCY

Meaning

The TRX has noticed a difference in frame numbers.

This is non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 607 (1095)

7543 FRAME NUMBER DISCREPANCY

Page 608: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

608 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 609: Alarm

2907544 CONFIGURATION FAILURE IN ABISAND DBUS INTERFACE OF TRX

Meaning

The DBIA ASIC is faulty in the TRX.

This is a fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit if the system does not cancel the alarm

within 30 seconds.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 609 (1095)

7544 CONFIGURATION FAILURE IN ABIS AND DBUS INTERFACEOF TRX

Page 610: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

610 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 611: Alarm

2917545 SAVING OPERATION IN TRXSUCCEEDED

Meaning

A successful burn operation in the flash memory has taken place

in the TRX.

This is an informative notification.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 611 (1095)

7545 SAVING OPERATION IN TRX SUCCEEDED

Page 612: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

612 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 613: Alarm

2927546 SAVING OPERATION IN TRXFAILED

Meaning

A failure in the burn operation in the flash memory in the TRX.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 613 (1095)

7546 SAVING OPERATION IN TRX FAILED

Page 614: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

614 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 615: Alarm

2937547 INTERNAL SIGNALLING FAILURE

Meaning

This alarm indicates a programming failure error in the SW.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 615 (1095)

7547 INTERNAL SIGNALLING FAILURE

Page 616: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

616 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 617: Alarm

2947548 DATA TRANSFER FAILURE ONTRANSCODER CONNECTION

Meaning

The TRAU bursts from the transcoder are erroneous.

This is an informative notification.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 617 (1095)

7548 DATA TRANSFER FAILURE ON TRANSCODERCONNECTION

Page 618: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

618 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 619: Alarm

2957549 INTERNAL DATA TRANSFERFAILURE

Meaning

A communication error between the I960 and the DSP.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 619 (1095)

7549 INTERNAL DATA TRANSFER FAILURE

Page 620: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

620 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 621: Alarm

2967550 FAILURE IN LOOP TEST OF SITETEST MONITOR

Meaning

A fault in the BSIA-CHDSP-CUBA-RFU-STM-RFU-EQDSP-CHDSP-BSIA

loop test. The BER values are too high, compared to the limit values.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 621 (1095)

7550 FAILURE IN LOOP TEST OF SITE TEST MONITOR

Page 622: Alarm

Instructions

Check if the TRX loop fails, too. If so, the fault is in the TRX.

If the internal TRX loop is in order, the fault is in the STM or

the antenna coupling devices (RTC, RMU or corresponding devices).

If the failure is in several sectors, then the fault is in the STM.

Replace the faulty unit. (A fault in the STM is not fatal.)

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

622 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 623: Alarm

2977551 FAILURE IN RX-ANTENNASUPERVISION TEST LOOP

Meaning

A fault in the loop test of the RX antenna supervision, in which

the STM loop test is performed twice with different values.

This is a non-fatal alarm.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 623 (1095)

7551 FAILURE IN RX-ANTENNA SUPERVISION TEST LOOP

Page 624: Alarm

Instructions

Check if the STM loop and the TRX loop fail too. Then follow the

instructions in the corresponding alarms (7937 and 7918). If the

loops are in order, the fault can be in the alarm limits. Check

the configuration file in the BCF.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

624 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 625: Alarm

2987552 FAULT IN TRX NON-VOLATILEMEMORY

Meaning

The backup version of the TRX software is invalid. The check sum of

the flash memory code is invalid, and the stored code is corrupted.

This is a non-fatal alarm. The BCF loads the software to the TRX.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 625 (1095)

7552 FAULT IN TRX NON-VOLATILE MEMORY

Page 626: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

626 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 627: Alarm

2997553 MEMORY FAULT IN DBUSINTERFACE OF TRX

Meaning

A memory test failure. The TRX processor is not able to communicate

with the D-bus.

This is a fatal alarm. TRX is blocked.

TRX

The TRX has four main tasks. It is the radio interface of the GSM (DCS)

base station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic between the

Abis interface and the radio interface. It also performs all baseband

operations for traffic data, for example, encryption, decryption,

coding, decoding and demodulation and combining the two branches in

the case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 627 (1095)

7553 MEMORY FAULT IN DBUS INTERFACE OF TRX

Page 628: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

628 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 629: Alarm

3007560 E-CELL ADJUSTMENT FAILED

Meaning

BCF sends the e-cell adjustment request to all TRXs and waits for

ACK or NACK. The BCF waits for the response for 10 seconds.

After receiving ACK, the BCF continues normally by sending the

dynamic configuration to TRXs.

If NACK is received or timer is expired, the configuration of that

TRX is stopped and this alarm is sent to the BSC and MMI after

the configuration.

E-CELL

Dynamic cell radius extension. Based on a solution with one BCCH

and two TRXs.

Different TRXs serve normal area and extended area. The TRX which

serves the normal area is normally configured with BCCH/SDCCH and TCHs.

The timing of receiver of the TRX which serves the extended area (E-TRX)

has been delayed so that it can serve an area beyond 35 kilometres.

BCF

The Base Control Function (BCF) unit is responsible for the operation

and maintenance of the BTS. The main functions of the BCF are:

loading of the BTS operational file packets from the BSC to the BTS,

initialising the BTS, continuous supervision of the BTS equipment,

reporting faults to the BSC and testing and operating functions.

The BCF is also the source of main clock pulses of the BTS.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 629 (1095)

7560 E-CELL ADJUSTMENT FAILED

Page 630: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

630 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 631: Alarm

3017590 ANTENNA PERFORMANCEDEGRADED

Meaning

The standing wave ratio of the antenna exceeds the lower alarm level.

The antenna adjustment is unbalanced. Calls can still be maintained.

BTS antennas

The BTS has two similar antennas. Both antennas have the receiving

and transmitting function.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check antenna connectors, cables and antenna elements.

External conditions can affect the antenna performance. The performance

may be improved by cleaning the antennas.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 631 (1095)

7590 ANTENNA PERFORMANCE DEGRADED

Page 632: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

632 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 633: Alarm

3027591 ANTENNA FAULTY

Meaning

The standing wave ratio of the antenna exceeds the higher alarm level.

The antenna adjustment is unbalanced.

If one of the antennas is faulty, the BTS automatically disables the

downlink and uplink diversity. The BTS uses the working antenna and

the faulty antenna is no longer used. Calls can still be maintained.

If both antennas are faulty, calls cannot be maintained.

BTS antennas

The BTS has two similar antennas. Both antennas have the receiving

and transmitting function.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty antenna or antennas.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 633 (1095)

7591 ANTENNA FAULTY

Page 634: Alarm

Cancelling

Cancel the alarm with an MML command after correcting the fault

as presented in the INSTRUCTIONS.

To cancel the alarm, unlock the alarming TRX by choosing the

lock/unlock command.

634 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 635: Alarm

3037592 LOW NOISE AMPLIFIERS OUT OFORDER

Meaning

Both of the low noise amplifiers are faulty. The BTS does not work and

calls are not available.

Low noise amplifier

The low noise amplifiers are located in the duplex filter. They amplify

the signals received from the antennas.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the BTS.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 635 (1095)

7592 LOW NOISE AMPLIFIERS OUT OF ORDER

Page 636: Alarm

636 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 637: Alarm

3047593 FAULT IN LOW NOISE AMPLIFIER

Meaning

One or both of the low noise amplifiers are faulty.

The fatality of the alarm depends on whether one or both of the low

noise amplifiers is faulty.

If one of the low noise amplifiers is out of order, RX diversity is

disabled. The BTS RF receiving capability is reduced. Calls are still

available.

If both of the low noise amplifiers are out of order, the BTS does not

function. Calls are not available.

Low noise amplifier

The low noise amplifiers are located in the duplex filter. They amplify

the received signals from antennas.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the BTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 637 (1095)

7593 FAULT IN LOW NOISE AMPLIFIER

Page 638: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

638 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 639: Alarm

3057594 ANTENNA TESTLOOP FAILURE

Meaning

The antenna testloop fails. The antenna is faulty if the alarm 7591

is active.

The antenna testloop does not operate correctly if external antennas are

used and the attenuation between antennas is greater than specified.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the BTS has internal antennas and the alarm 7591 is active, replace

the faulty antenna.

If external antennas are used, check the attenuation between the

antennas. The antenna testloop does not operate correctly if the

attenuation between antennas is greater than specified (see

BTS Customer Documents). In that case no actions are needed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 639 (1095)

7594 ANTENNA TESTLOOP FAILURE

Page 640: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

640 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 641: Alarm

3067600 BCF FAULTY

Meaning

Critical fault (or faults) has occurred in the base station.

This alarm blocks the base station.

The fault reason can be read from the supplementary text

field of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason: Base station synchronisation failed.

Instructions:

1. Check the synchronisation cabling.

2. If the cabling is OK, replace the master TRX (TRX-1).

3. Reset the BCF.

Fault reason: Power unit is probably broken.

Instructions:

1. If the power supply unit LED is green, check the TRXs and

replace the faulty TRX. TRX connectors are probably broken.

2. If the power supply unit LED is red,

replace the power supply unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 641 (1095)

7600 BCF FAULTY

Page 642: Alarm

Fault reason: Oven oscillator is broken.

Instructions:

1. Replace the VIFA unit.

Fault reason: Temperature inside the TRX is dangerously high.

Instructions:

1. Check whether the following alarm is active:

7621 INTOLERABLE CONDITIONS ON SITE

and follow the instructions given for the alarm.

2. Even if alarm 7621 is not active, and there is only one

TRX in the cabinet, follow the instructions given for alarm 7621.

3. If alarm 7621 is not active and the cabinet has more than one TRX,

replace the master TRX.

Note: An alarm is activated when the TRX unit internal

temperature exceeds +85 C.

Other fault reasons

Instructions:

1. Check whether either of the following alarms is active:

7606 TRX FAULTY

7603 BTS FAULTY

and follow the instructions given for the active alarm(s).

INSITE:

Fault reason: Temperature inside the BTS is too high.

Instructions:

1. Ensure that the environment of the base station

site meets the conditions specified for Nokia InSite Base Station.

If necessary, move the base station to a different location.

2. Reset the BCF.

3. If the alarm reappears after the recovery actions above,

replace the BTS.

Fault reason: The TX output power is out of limits (over maximum or under

minimum).

Instructions:

1. Reset the BCF.

2. If the alarm reappears, replace the BTS.

Other fault reasons

Instructions:

1. Reset the BCF.

2. If the alarm reappears, replace the BTS.

ULTRASITE:

Fault reason: Oven oscillator is broken.

Instructions:

1. Replace the BOI.

Fault reason: Base station synchronisation failed.

Instructions:

1. Check that the synchronisation source is up and alive.

2. Check that the transmission settings are OK.

642 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 643: Alarm

3. Check the synchronisation cabling.

4. If the cabling is OK, replace the BOI.

Other fault reasons

Instructions:

1. Check whether either of the following alarms is active:

7606 TRX FAULTY

7603 BTS FAULTY

and follow the instructions given for the active alarm(s).

FLEXI EDGE:

Fault reason: Critical Transmission Licence is missing at the BSC.

Instructions:

Check for Transmission licence related transmission alarms:

- for alarm 8273, activate the feature "Flexi EDGE Abis over IP/

Ethernet" in the BSC RNW database

- for alarm 8274, activate the feature "Flexi EDGE Additional 2 E1/T1"

or increase the feature capacity in the BSC RNW database

or alternatively, remove terminated Abis traffic or Abis mapping until

the number of the licensed 2 E1/T1 interfaces is equal to or greater

than the number of the interfaces or the Abis mapping bundles carrying

the local terminated Abis traffic. Only the 2 E1/T1 interfaces are

licence free.

Fault reason: Air i/f reference clock 26 MHz not available.

Description: ESMA System module detected that its Oven Controlled 26 MHz

Oscillator is broken.

Instructions:

1. Issue a HW reset to ESMA from (remote) BTS Manager.

Note: This site's bypass transmission will be cut for 1-2 minutes.

2. Replace ESMA.

Fault reason: ESEA System Extension module reported HW failure

Description: ESMA System module detected that a hardware failure has

occurred in the ESEA System Extension module.

Instructions:

1. Issue HW reset to ESEA from BTS Manager.

2. If fault persists, replace ESEA and reset the BCF.

Fault reason: ESMA System module has lost connection to ESEA System

Extension module

Description: ESEA System Extension module does not respond to polling

command from ESMA System module.

Instructions:

1. Check the power distribution to ESEA.

2. Check that the bus cable is correctly mated between ESMA and

ESEA.

3. Replace ESEA.

4. Replace ESMA.

Fault reason: ESEA System Extension module SW upgrade failed

Description: ESMA System module detected that SW download to ESEA

System Extension module failed at startup.

Instructions:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 643 (1095)

7600 BCF FAULTY

Page 644: Alarm

1. Issue a HW reset to ESEA.

2. Issue a HW reset to ESMA.

3. If alarm persists, replace ESEA.

4. Replace ESMA.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

In UltraSite Base Station the alarm has to be cancelled manually

if baseband hopping is used.

In Flexi EDGE Base Station, if the fault reason "ESEA System

Extension module SW upgrade failed" occurs, you must cancel the

alarm manually.

644 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 645: Alarm

3077601 BCF OPERATION DEGRADED

Meaning

A major fault (or faults) has occurred in the base station.

Check the fault reason from the supplementary text field of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason: Cabinet I2C bus is jammed.

Instructions:

1. Switch the site power off and on.

2. Check the fan unit, the power supply unit and the TRXs.

If necessary, replace the faulty units(s).

3. If the fault reappears, replace the cabinet. The units

inside the cabinet can be reused in the new cabinet.

Fault reason: Difference between PCM and base station frequency reference.

Instructions:

1. Check the cabling

2. If the cabling is OK, replace the master TRX.

Fault reason: Incompatible unit presence has been detected in the BTS.

Instructions:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 645 (1095)

7601 BCF OPERATION DEGRADED

Page 646: Alarm

1. Replace the high power or EDGE TRX(s) with normal type TRX(s)

and reset the BCF.

2. Or, replace the normal type FAN and power supply with

high power or EDGE units.

Now EDGE and high power TRXs are supported.

Other fault reasons

Instructions:

1. Check whether one or several of the following alarms are active:

7606 TRX FAULTY

7603 BTS FAULTY

7607 TRX OPERATION DEGRADED

7604 BTS OPERATION DEGRADED

and follow the instructions given for the active alarm(s).

INSITE:

Fault reason: AC is off and the battery voltage is too low or battery

is being charged.

Instructions:

1. Check the mains supply.

2. Check the power supply unit and replace if necessary.

3. If the alarm reappears after the recovery actions above,

replace the BTS.

Fault reason: Difference between the PCM and BTS frequency reference.

Instructions:

1. Check the synchronisation settings of the transmission interface.

2. If the settings are OK, check the transmission chain.

3. If the alarm stays active or reappears after the recovery actions

above, reset the BCF.

4. If the alarm reappears after the BCF reset, replace the BTS.

Fault reason: Flash operation failed.

Instructions:

1. Reset the BCF.

2. If the alarm reappears, replace the BTS.

Fault reason: The TX output power has dropped at least 3 dB.

Instructions:

1. No immediate actions required.

2. If the alarm stays active or reappears frequently, replace the BTS.

Fault reason: Oven oscillator control is close to its margins. The oven

might be outdated.

Instructions:

1. Check the synchronisation settings of the transmission interface.

2. If the settings are OK, check the transmission chain.

3. If the alarm stays active or reappears after the recovery actions

above, reset the BCF.

4. If the alarm reappears after the BCF reset, replace the BTS.

ULTRASITE:

Fault reason: Power unit output voltage fault.

Instructions:

646 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 647: Alarm

1. Replace all faulty power units.

Fault reason: Power unit input voltage fault.

Instructions:

1. Ensure that the input voltage is correct.

2. Replace all faulty power units.

Fault reason: No connection to power unit.

Instructions:

1. Replace all faulty power units.

Fault reason: Power unit temperature is dangerously high.

Instructions:

1. Ensure that the ambient temperature of the base station is within

specified limits.

2. Check the cabinet fans.

3. Replace the faulty power unit(s).

Note: An alarm is activated when the PWSX internal

temperature exceeds +85 C.

Fault reason: Transmission unit temperature is dangerously high.

Instructions:

1. Ensure that the ambient temperature of the base

station is within specified limits.

2. Check the cabinet fans.

3. Replace the faulty transmission unit.

Note: An alarm is activated when the transmission

unit internal temperature exceeds +85 C.

Fault reason: Difference between PCM and base station frequency

reference.

Instructions:

1. Check the network synchronisation between the BSC and

the base station

2. Check the transmission synchronisation settings

on the transmission card.

3. Check the transmission cabling at the site.

4. Replace the BOI.

Note: After corrective actions, it may take several

hours to adjust the clock and the alarm to disappear.

Fault reason: Flash operation failed in BOI or TRX.

Instructions:

1. Replace the BOI.

Fault reason: BOI detected that the site support is dumb.

Instructions:

1. Check the SISU cabinet and the connection.

Other fault reasons

Instructions:

1. Check whether one or several of the following alarms are active:

7606 TRX FAULTY

7603 BTS FAULTY

7607 TRX OPERATION DEGRADED

7604 BTS OPERATION DEGRADED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 647 (1095)

7601 BCF OPERATION DEGRADED

Page 648: Alarm

7602 BCF NOTIFICATION

and follow the instructions given for the active alarm(s).

Flexi EDGE:

Fault reason: Difference between PCM and BTS frequency reference.

Description: There is over 5 Hz difference to the 2MHz reference clock

due to Abis link instability.

Instructions:

1. Check that Synchronisation priority list has correct Rx clock

sources.

2. Check the Abis link quality (G.826 performance statistics via BTS

Manager/NetAct). Check the alarm history for 8xxx alarms reported

and resolve any link problems occurred.

3. Check the network synchonisation between the BSC and the base

station.

4. If alarm is active at multiple sites, check the quality of

synchronisation for the whole BSS.

Fault reason: ESMA System module has lost connection to FSEx External

Alarm (EAC) module.

Description: FSEx External Alarm (EAC) module does not respond to poll

message of the ESMA System module.

Instructions:

1. Check that FSEx is set to Active Mode by connecting pins 3-4 of

X1103 jumper.

2. Check that the cabling is correctly mated between ESMA and FSEx.

3. Replace FSEx.

4. Replace ESMA.

Fault reason: ESMA System module cooling fan(s) report no rotation.

Description: One or more fans of the ESMA System module are not rotating.

There is a danger of overheating.

Instructions:

1. Check that the fan unit cable is correctly mated to ESMA.

2. Check that there are no obstacles preventing the fan(s) from

rotating.

3. Clean the fan unit of dust and/or dirt.

4. Replace the fan unit.

5. Replace ESMA.

Fault reason: Commissioning failed due to BCF ID mismatch between

commissioning file and BSC.

Description: Incorrect BCF ID between the BSC and the Commissioning

File (SCF).

Instructions:

1. Check the transmission path of the traffic allocated to the site

against the network plan.

2. Using the (remote) BTS Manager, recommission the BTS with correct

BCF ID.

Fault reason: ESMA System module FLASH memory writing error.

Description: Memory write failure occurred at SW download and is not

valid, previously active SW is taken into use.

Instructions:

1. Issue a HW reset to ESMA from (remote) BTS Manager.

2. Attempt the SW download again.

648 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 649: Alarm

3. If this alarm persists, replace ESMA.

Fault reason: All external Q1 devices fail to respond.

Description: None of the configured Q1 devices in the Q1 bus are

responding to a polling command.

Instructions:

1. Check that Q1 addresses and baud rate match between the Q1 devices

and BSC.

2. If FIFA is used and BTS is polling Q1 equipment, check that Q1

switch towards the Q1 bus is closed with FlexiHub Manager.

3. Check that the Q1 cables are correctly mated between the ESMA and

Q1 devices.

4. Replace ESMA.

Fault reason: Commissioning file climate control profile mismatch, no fans

detected.

Description: Climate control profile indicates an installed fan unit but

it is missing from the actual configuration. There is a danger of

overheating.

Instructions:

1. If none of the modules at the site require fan units, change the

fan profile to "No Fans" in the SCF and re-commission the site.

2. Check that the fan unit cable is correctly mated to ESMA.

3. Replace the fan unit.

4. Replace the ESMA.

Fault reason: Module power cable connections are incorrectly configured.

Description: One or more of the internal power cable connections does not

match power cabling rules. Intelligent shutdown feature may not operate

correctly.

Instructions:

1. Check the internal power and bus cabling against the product

documentation set.

2. Issue a BCF reset.

Fault reason: ESEA System Extension Module fan(s) out of order

Description: ESEA System Extension module detected reduced speed or no

rotation of fan(s) against commanded speed.

Instructions:

1. Check that the fan unit cable is correctly mated to ESEA.

2. Check that there are no obstacles preventing the fan(s) from

rotating.

3. Clean the fan unit of dust and/or dirt.

4. Replace the fan unit.

5. Replace ESEA.

Cancelling

This is a start/cancel type alarm.

For the fault reasons "Incompatible unit presence has been detected in

the BTS," "ESMA System module FLASH memory writing error", or "Module

power cable connections are incorrectly configured", alarm is cancelled

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 649 (1095)

7601 BCF OPERATION DEGRADED

Page 650: Alarm

manually (BCF reset).

For other fault reasons alarm is cancelled automatically.

650 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 651: Alarm

3087602 BCF NOTIFICATION

Meaning

A minor fault (or faults) has occurred in the base station.

The fault reason can be read from the supplementary text field of the

alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See Alarm Structure

Instructions

METROSITE:

Fault reason: BSS synchronisation failed.

Instructions:

1. Check the clock cabling between the external clock source

and the BCF.

Fault reason: External synchronisation signals disabled

Instructions:

1. Check the clock cabling between the LMU and the BCF.

2. Check that the GPS signal cable is connected to the LMU.

Fault reason: Temperature inside the TRX is high.

Instructions:

1. Check whether the following alarm is active for fan unit:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 651 (1095)

7602 BCF NOTIFICATION

Page 652: Alarm

7605 BTS NOTIFICATION

and follow the instructions given for the alarm.

2. Even if there are no active alarms for the fan unit, check that no

foreign objects obstruct the airflow.

3. If alarm 7605 is not active, ensure that the

ambient temperature of the base station is within acceptable

limits.

Note: An alarm is activated when the TRX unit internal temperature

exceeds +80C.

Fault reason: Temperature inside the TRX is low.

Instructions:

1. Ensure that the ambient temperature is within acceptable limits.

also check the fan unit.

Note: An alarm is activated when the TRX's internal temperature

is below -10C.

Fault reason: Fan unit is broken.

Instructions:

1. Check whether the fan unit is installed.

2. When there is a fan unit installed, check if something has jammed

the fan unit and remove the jamming object. Otherwise replace the

fan unit.

ULTRASITE:

Fault reason: Power unit temperature is low.

Instructions:

1. Ensure that the ambient temperature of the base station is

within specified limits.

2. Check that the heater is working properly if equipped.

3. Replace the PWSx.

Note: An alarm is activated when the PWSx internal

temperature is below -10C.

Fault reason: Transmission unit temperature is low.

Instructions:

1. Ensure that the ambient temperature of the base

station is within specified limits.

2. Check that the heater is working properly if equipped.

3. Replace the transmission unit.

Note: An alarm is activated when the transmission

unit's internal temperature is below -10C.

Fault reason: Power unit has lost connection to temperature sensor.

Instructions:

1. If another slot in the cabinet is empty, move the

power unit into the empty slot.

2. The temperature sensor is probably broken.

Temperature changes cannot be measured.

Replace the power unit.

Fault reason: Transmission unit has lost connection to temperature sensor.

Instructions:

1. Temperature sensor is probably broken.

Temperature changes cannot be measured.

652 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 653: Alarm

Replace the transmission unit.

Fault reason: BOI detected that connection to transmission unit is lost.

Instructions:

1. Open the Nokia BTS Manager and check the active alarms.

If this base station or other base stations beyond it

otherwise operate properly, there is no need for

an immediate repair. However, the transmission alarms for

the faulty unit are not reported to the BSC nor the

Nokia BTS Manager.

2. Reset the faulty transmission unit.

Note: Resetting the unit affects the traffic routed through it.

3. If the alarm reappears after the transmission unit

reset, switch the cabinet power off and on.

4. If the alarm reappears after the recovery actions

above, replace the faulty transmission plug-in unit.

Fault reason: Cooling fan is broken.

Instructions:

1. If something has jammed the cooling fan unit,

remove the jamming object.

2. Check which fan is giving the alarm from the

supplementary information (rack/shelf/slot).

3. If the TSxx fan is alarming:

. Remove the TSxx in front of the fan. If the fan

starts working, the removed TSxx is broken.

. If the fan still does not rotate after the first

TSxx was removed, reinsert it and remove

the second TSxx. If the fan starts rotating,

the second TSxx is broken.

. If the fan does not work after the TSxx

removal test, the fan is broken and must be

replaced.

4. For other fan alarms, replace the corresponding fan unit.

5. Otherwise, replace the BOI.

Note: This alarm is related to fans located in the back

of the cabinet.

Fault reason: Cabinet fan is broken.

Instructions:

1. Check that the fan cable is connected to the door switch box.

2. If something has jammed the cabinet fan unit, remove the

jamming object. Otherwise, replace the fan unit.

3. Replace the door switch box.

4. Otherwise, replace the BOI.

Note: This alarm is related to door fan.

Fault reason: Cooling fan speed has reduced from the set speed.

Instructions:

1. If the fan is dirty, clean the fan unit.

2. If something has jammed the cooling fan unit, remove the

jamming object. Otherwise, replace the fan unit.

Note: This alarm is related to fans located in the

back of the cabinet.

Fault reason: Cabinet fan speed has reduced from the set speed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 653 (1095)

7602 BCF NOTIFICATION

Page 654: Alarm

Instructions:

1. If the fan is dirty, clean the fan unit.

2. If something has jammed the cabinet fan unit,

remove the jamming object. Otherwise, replace the fan unit.

Note: This alarm is related to door fan.

Fault reason: Heater is broken.

Instructions:

1. Check that the heater cable is connected to the door switch box.

2. Check that the AC power supply is OK by measuring AC from

the cabinet connection box (the heater always requires AC power).

3. Replace the faulty heater, or the heater is not installed

although it is defined in the configuration file,

therefore an alarm is issued. Install the heater.

Fault reason: Power unit output voltage fault.

Instructions:

1. Replace the faulty power unit.

The cabinet has more than one power supply

unit. The other power units are still functioning.

Fault reason: Power unit input voltage fault.

Instructions:

1. Ensure that the input voltage is correct.

2. Replace the faulty power unit. The cabinet has more than one

power supply unit. The other power units are still functioning.

Fault reason: No connection to power unit.

Instructions:

1. Check if the power unit is switched off.

2. If the power unit is on, replace the faulty power unit.

The cabinet has more than one power supply unit.

The other power units are still functioning.

Fault reason: Common rack PWS I2C bus is jammed.

Instructions:

1. Give a one-minute power reset to the whole BTS cabinet.

2. Check the power unit(s) and power backplane connectors,

and replace if faulty.

Fault reason: Common rack EAC I2C bus is jammed.

Instructions:

1. Give a one-minute power reset to the whole BTS cabinet.

2. Reset the BCF.

3. If the cabling between the BOI and the Interface board on the

top side of the cabinet is OK, replace the Interface board.

4. Replace the BOI.

5. Replace the common backplane.

Fault reason: Mismatch between BSC/MMI configuration file

and the actual configuration.

Instructions:

1. Check that all units are installed and working OK.

2. Check that the actual base station configuration,

HW configuration file and BSC configuration match.

Make necessary corrections.

654 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 655: Alarm

Fault reason: BSS synchronisation failed.

Instructions:

1. Check the clock cabling between the external clock source

and the BCF.

Fault reason: External synchronisation signals disabled

Instructions:

1. Check that the master clock source is OK.

2. Check the clock cabling between the LMU and the BCF.

3. Check that the GPS signal cable is connected to the LMU.

Other fault reasons

Instructions:

See the Alarm Descriptions document included in the BTS SW release

binder of the alarming base station type.

Flexi EDGE:

Fault reason: External synchronisation signals disabled.

Description: LMU has operated without GPS signal over specified time and

is turning its FCLK output off.

Instructions:

1. Check the GPS antenna fix status is OK with LMUManager. Adjust the

GPS antenna so that satellites become visible.

2. Check that the GPS cable is correctly mated to LMU.

3. Check that the latest LMU SW is being used. Download newer SW if

necessary.

4. Replace LMU.

Fault reason: BSS synchronisation failed.

Description: ESMA System module has lost synchronisation signal at

synchronisation input (SIN) port.

Instructions:

1. If LMU provides the synchronisation, check if alarm 8202 is active

and resolve it.

2. If another BTS is the synchronisation master, check if that it is up

and alive.

3. Check that the synchronisation cabling is correctly mated between the

units. If LMU is used, check also Q1 cabling and power supply to the

LMU unit.

4. Replace ESMA.

Fault reason: ESMA System module cooling fan speed has deviated from the set

speed.

Description: There is more than 20% deviation in fan speed between commanded

and actual value.

Instructions:

1. Check that nothing obstructs the fan(s) from rotating.

2. Clean the fan unit of dust and/or dirt.

3. Replace the fan unit. Note: If "Temperature high/dangerously high"

and/or 7621 alarm(s) are also active, perform these actions as soon

as possible.

Fault reason: ESMA System module temperature high.

Description: ESMA System module has detected that its internal temperature

has exceeded +90C/+194F.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 655 (1095)

7602 BCF NOTIFICATION

Page 656: Alarm

Instructions:

1. Ensure that the ambient temperature of the base station is below

+50C/+122F.

2. Check if any fan alarms are also active. If active, refer to fan

alarm instructions to resolve.

3. Replace the ESMA.

Fault reason: ECxx RTC module connected to wrong port.

Description: ECxx RTC module is not connected to port 1/2/3 of ESMA

System module.

Instructions:

1. Connect ECxx to ESMA port 1,2 or 3 and issue a BCF reset.

Fault reason: EXxx TRX module connected to wrong port.

Description: EXxx TRX Module is not connected to ESEA System Extension

module.

Instructions:

1. Connect EXxx module to ESEA.

Fault reason: ESEA System Extension module connected to wrong port.

Description: ESEA System Extension module is not connected to port 6 of

ESMA System Module.

Instructions:

1. Connect ESEA to port 6 of ESMA, and issue a BCF reset.

Fault reason: Unknown module connected to Esxx System (Extension) module.

Description: ESMA System module does not recognise the module connected to

this port. SW release incompatibility with the connected HW.

Instructions:

1. Check the HW \ SW compatibility from the SW release binder.

a. If the module is compatible with the current SW running in the BTS,

replace the module.

b. If the module is not compatible with the current SW running in the

BTS, check which SW version supports the module. Upgrade the BTS SW

to the version that supports the module.

2. Remove the unknown module

Fault reason: ESEA System Extension module temperature high.

Description: Internal temperature of ESEA System Extension module has

exceeded +90C/+194F.

Instructions:

1. Ensure that the ambient temperature of the base station is below

+50C/+122F.

2. If the fault persists, replace ESEA.

Fault reason: ESMA System module unable to read internal temperature

sensors.

Description: There is no temperature measurement in the ESMA System

module. All temperature sensors inside the module are broken. Fans are

rotating at maximum speed.

Instructions:

1. Replace the ESMA.

Note: If fan alarm(s) are active at ESMA, perform this action

as soon as possible.

Fault reason: ESEA System Extension module connected to wrong port

656 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 657: Alarm

Description: ESEA System Extension module is not connected to port 6

of ESMA System Module.

Instructions:

1. Connect ESEA to port 6 of ESMA, and issue a BCF reset.

Fault reason: ESEA System Extension module temperature high

Description: Internal temperature of ESEA System Extension module has

exceeded +85C/+185F.

Instructions:

1. Ensure that the ambient temperature of the base station is below

+50C/+122F.

2. Check if fan alarm is also active. If active, refer to fan alarm

instructions to resolve.

3. Replace ESEA.

Fault reason: EOCA Optical module connected to wrong port

Description: EOCA Optical module is not connected to ESMA System

Extension module.

Instructions:

1. Connect Local and Remote EOCA to ESEA.

Cancelling

This is a start/cancel type alarm. Alarm is cancelled automatically.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 657 (1095)

7602 BCF NOTIFICATION

Page 658: Alarm

658 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 659: Alarm

3097603 BTS FAULTY

Meaning

A critical fault (or faults) has occurred in a unit (or units) that

belong to the sector indicated in the alarm.

This alarm blocks the alarming sector.

Check the fault reason from the supplementary text field of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

METROSITE, ULTRASITE and Flexi EDGE:

All fault reasons

Instructions:

1. Check whether either of the following alarm is active:

7606 TRX FAULTY

7607 TRX OPERATION DEGRADED

and follow the instructions given for the active alarm(s).

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 659 (1095)

7603 BTS FAULTY

Page 660: Alarm

Cancelling

This is a start/cancel type alarm. The alarm is cancelled automatically.

In UltraSite base stations alarm has to be cancelled

manually if baseband hopping is used.

660 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 661: Alarm

3107604 BTS OPERATION DEGRADED

Meaning

Major fault (or faults) has occurred in a unit (or units) that

belong to the sector indicated in the alarm.

The fault reason can be read from the supplementary text field

of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Other fault reasons

Instructions:

1. Check whether either of the following alarms is active:

7606 TRX FAULTY

7607 TRX OPERATION DEGRADED

and follow the instructions given for the active alarm(s).

ULTRASITE:

Fault reason: Remote tune combiner temperature is dangerously high.

Instructions:

1. Ensure that the ambient temperature of the base station is within

specified limits.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 661 (1095)

7604 BTS OPERATION DEGRADED

Page 662: Alarm

2. Check the cabinet fans.

3. Replace the RTxx.

Note: An alarm is activated when the RTxx unit

internal temperature exceeds +70C.

Fault reason: Remote tune combiner temperature is low.

Instructions:

1. Ensure that the ambient temperature of the base station is within

specified limits.

2. Check that the heater is working properly if equipped.

3. Replace the RTxx.

Note: An alarm is activated when the RTxx unit

internal temperature is below -10C.

Fault reason: Rx levels differ too much between main and diversity antennas.

Instructions:

1. Check the RSSI measurements by BTS Manager.

2. Check and measure the antenna lines.

3. Check the BTS RF cables and connections.

4. Replace the combiner unit.

Check that the RXDL parameter at the BSC is set to a

reasonable value, taking into account the site conditions

in order to prevent unnecessary alarms.

5. Replace the TSxx unit.

Other fault reasons

Instructions:

1. Check whether either of the following alarms is active:

7606 TRX FAULTY

7607 TRX OPERATION DEGRADED

and follow the instructions given for the active alarm(s).

Flexi EDGE:

Other fault reasons

Instructions:

1. Check whether either of the following alarms is active:

7606 TRX FAULTY

7607 TRX OPERATION DEGRADED

and follow the instructions given for the active alarm(s).

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

662 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 663: Alarm

3117605 BTS NOTIFICATION

Meaning

A minor fault (or faults) has occurred in a unit (or units) that

belong to the sector indicated in the alarm.

Check the fault reason from the supplementary text field of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason: Fan unit operation degraded

Instructions:

1. If something has jammed the fan unit, remove the jamming object.

Otherwise replace the fan unit.

ULTRASITE:

Fault reason: Remote tune combiner flash checksum is invalid

and the code is corrupted.

Instructions:

1. Reset the sector.

2. If the fault reappears, replace the RTxx.

Fault reason: Cavity stepper motor cannot tune the remote tune combiner.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 663 (1095)

7605 BTS NOTIFICATION

Page 664: Alarm

Instructions:

1. Reset the sector.

2. If the fault reappears, replace the RTxx.

Fault reason: Remote tune combiner has lost connection to

temperature sensor.

Instructions:

1. Reset the sector.

2. Replace the RTxx.

Flexi EDGE:

Fault reason: ECxx RTC module cooling fan speed has deviated from the set

speed.

Description: There is more than 20% deviation in fan speed between

commanded and actual value.

Instructions:

1. Check that nothing obstructs the fan(s) from rotating.

2. Clean the fan unit of dust and/or dirt.

3. Replace the fan unit. Note: If "Temperature high/dangerously high"

and/or 7621 alarm(s) are also active, perform these actions as soon

as possible.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

664 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 665: Alarm

3127606 TRX FAULTY

Meaning

Critical fault has occurred in a TRX.

This alarm blocks the TRX.

The fault reason can be read from the supplementary text field

of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason: Failure detected during TRX configuring.

Instructions:

1. Either the TRX is faulty or its frequency band is different

from the one that was configured into BSC. Replace the TRX

with a functional TRX or with another TRX with correct

frequency band.

2. Incompatible TRX power type in BB hopping sector.

Mixture of High and Low Power TRXs is used in a BB hopping

enabled sector. Replace the incompatible TRX power type.

Fault reason: Antenna connection is faulty.

Instructions:

1. Check the antenna and cabling. If the antenna and cabling

are faulty, correct the problem and run TRX test to cancel

the alarm.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 665 (1095)

7606 TRX FAULTY

Page 666: Alarm

2. If the antenna and cabling are OK, TRX is faulty.

Replace the faulty TRX.

Fault reason: TRX test result antenna connection faulty.

Instructions:

1. Check the antenna and cabling. If the antenna and cabling

are faulty, correct the problem and run TRX test again to

cancel the alarm.

2. If the antenna and cabling are OK, TRX is faulty. Replace

the faulty TRX.

Fault reason: External frame clock synchronisation failed.

Instructions:

1. Check the cable connected to the VIFA unit.

2. If the cabling is OK, check the slave cabinet's master TRX.

3. If the slave cabinet's master TRX is faulty, replace it.

Fault reason: External frame clock is missing.

Instructions:

1. Check the cable connected to the VIFA unit.

2. If the cabling is OK, check the slave cabinet's master TRX.

3. If the slave cabinet's master TRX is faulty, replace it.

Fault reason: External frame number synchronisation failed.

Instructions:

1. Check the cable connected to the VIFA unit.

2. If the cabling is OK, check the slave cabinet's master TRX.

3. If the slave cabinet's master TRX is faulty, replace it.

Fault reason: FBUS HW failure.

Instructions:

1. Reset the sector.

2. Replace the TRX units one by one.

Fault reason: IDD main/auxiliary TRX frequency band mismatch.

Instructions:

1. Check the IDD configuration (TRX frequency band)

from the BTS Manager.

2. Ensure that the frequency bands of the IDD TRX units are

correct.

Fault reason: Non EDGE TRX device type used accidentally in IDD mode.

Instructions:

1. Check the IDD configuration (TRX unit type) from the BTS

Manager.

2. Ensure that the unit types of the IDD TRX units are correct.

Fault reason: Non EDGE TRX device type used accidentally in EDGE

capable mode.

Instructions:

1. Replace Non EDGE TRX with EDGE TRX (STIRC sector enabled).

Other fault reasons:

Instructions:

1. Replace the faulty TRX.

666 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 667: Alarm

ULTRASITE:

Fault reason: Non EDGE TRX device type used accidentally in EDGE

capable mode.

Instructions:

1. For STIRC enabled sector, replace Non EDGE TRX (BB2A plus non

EDGE RFU (TSxA)) with EDGE TRX or hybrid TRX. Note that hybrid

TRX is EDGE baseband (BB2E\F) plus Non EDGE RFU (TSxA).

Fault reason: Antenna connection is faulty.

Instructions:

1. Check the TSxx TX cable. Replace if faulty and reset TRX to

cancel the alarm.

2. If the TX cable is OK, the TSxx is faulty. Replace the TSxx.

Note: An alarm reports only if the PMAX value is 0 or 2 (two

highest power levels). If a sector configured with RTxx is

reset, while the antenna cable is disconnected, and if there

is no traffic in the current TRX, Alarm 7606 TRX FAULTY with a

fault reason 'Tuning carrier is not detected in remote tune

combiner' is issued.

Fault reason: Fault in VSWR antenna monitoring.

Instructions:

1. Check the antenna line and Bias-T cabling. Reset the sector.

2. Check all RF cabling between the TSxx's TX output connector

and top of the cabinet (including WCDx and DVxx or RTxx units).

3. Replace the Bias-T.

4. Replace TSxx.

Fault reason: Fault in the chain between power unit and MHA.

Instructions:

1. Check the voltage supply chain between

the PWSx unit(s) and the MHA.

2. Replace the PWSx.

3. Replace the Bias-T.

4. Replace the MHA.

Fault reason: Failure detected during TRX configuring.

Instructions:

1. Check whether the TSxx/DVxx/RTxx frequency is compatible with

the BSC network parameters.

2. Reset the TRX/sector.

3. Replace the TSxx.

Fault reason: BOI detected that connection to TRX is lost.

Instructions:

1. Check the BTS configuration and install the BB2x if it is

missing.

2. Replace the BB2x. Reset the TRX/sector.

Note: This alarm refers to the connection between BOIA and BB2x.

Do not replace TSxx in this case.

Fault reason: Failure in 26 MHz clock input.

Instructions:

1. If all TRXs indicate this fault, replace the BOI.

2. If only one TRX indicates this fault, replace the BB2x.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 667 (1095)

7606 TRX FAULTY

Page 668: Alarm

Fault reason: BOI or TRX has detected a failure in the incoming

frame clock signal.

Instructions:

1. If all TRXs indicate this fault, replace the BOI.

2. If only one TRX indicates this fault, replace the BB2x.

Fault reason: Interface problems between O&M and DSP SW.

Instructions:

1. Reset the TRX/sector.

2. If the fault reappears, replace the BB2x.

Fault reason: Failure in internal DSP monitoring loop.

Instructions:

1. Reset the TRX/sector.

2. If the fault reappears, replace the BB2x.

Fault reason: The synthesizer in remote tune combiner is faulty.

Instructions:

1. Replace the RTxx that is connected to the alarming TRX.

Fault reason: The controller is out of order in remote tune combiner.

Instructions:

1. Replace the RTxx that is connected to the alarming TRX.

Fault reason: The tuning of a cavity has failed in remote tune

combiner.

Instructions:

1. Reset the TRX.

2. If the TSxx is faulty, replace it.

3. Check the RTxx cabling.

4. If cabling is OK, replace the RTxx connected to the alarming

TRX.

Fault reason: Cavity reset has failed, cavity is not available in

remote tune combiner.

Instructions:

1. Reset the sector.

2. If the fault reappears, replace the RTxx connected to

the alarming TRX.

Fault reason: Tuning carrier is not detected in remote tune combiner.

Instructions:

1. Check that the TRX LAPD link is working.

2. Check the RTxx cabling.

3. If cabling is OK, replace the faulty TSxx.

4. If the fault reappears, replace the RTxx

connected to the alarming TSxx.

Fault reason: LNA main branch in remote tune combiner is faulty.

Instructions:

1. The LNA main branch is faulty.

Replace the RTxx connected to the alarming TRX.

Fault reason: LNA diversity branch in remote tune combiner is faulty.

Instructions:

668 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 669: Alarm

1. The LNA diversity branch is faulty.

Replace the RTxx connected to the alarming TRX.

Fault reason: The reflected power of remote tune combiner is too

high.

Instructions:

1. Check the antenna connection to the RTxx.

2. If the antenna connection is OK, replace the RTxx.

Fault reason: Software downloading to remote tune combiner failed.

Instructions:

1. Check the cabling from the RTxx to the backplane.

2. Reset the sector.

3. If the fault reappears, replace the RTxx.

Fault reason: Remote tune combiner initialisation failed.

Instructions:

1. Check the cabling from the RTxx to the backplane.

2. Reset the sector.

3. If the fault reappears, replace the RTxx.

Fault reason: No connection to remote tune combiner.

Instructions:

1. Check the cabling from the RTxx to the backplane.

2. If the connection is OK, replace the RTxx.

Fault reason: 1st branch LNA in dual variable gain duplex unit is

faulty.

Instructions:

1. Replace the DVxx.

Fault reason: 2nd branch LNA in dual variable gain duplex unit is

faulty.

Instructions:

1. Replace the DVxx.

Fault reason: BB2x temperature is dangerously high.

Instructions:

1. Ensure that the ambient temperature of the base station is

within specified limits.

2. Check the cabinet fans.

3. Replace the BB2x.

Note: An alarm is activated when the BB2x internal

temperature exceeds +70°C.

Fault reason: TSxx temperature is dangerously high.

Instructions:

1. Ensure that the ambient temperature of the base station is

within specified limits.

2. If air filters are used, check that they are not clogged.

3. If outdoor cabinet is used, check the door fan.

4. Check the cabinet fans.

5. Replace the TSxx.

Note: An alarm is activated when the TSxx internal

temperature exceeds +85°C.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 669 (1095)

7606 TRX FAULTY

Page 670: Alarm

Fault reason: There is disturbance in the serial DL bus or bus is

broken.

Instructions:

1. Reset the TRX/sector.

2. Check that the BB2x-TSxx HW configuration is valid.

3. Swap the unit with another working (non-alarming) TSxx unit

in the cabinet.

4. If the new TSxx raises the same alarm, check the

backplane connectors. If alarms follow the original TSxx,

replace the unit.

Fault reason: No data is received from DIBA

Asic traffic channels to CHDSP.

Instructions:

1. Replace the BB2x.

Fault reason: IDD main/auxiliary TRX frequency band mismatch.

Instructions:

1. Check the IDD configuration (TSxx frequency band)

from the HW Configurator.

2. Ensure that the frequency bands of the IDD TSxx units are

correct.

Fault reason: Non EDGE TRX device type used accidentally in IDD mode.

Instructions:

1. Check the IDD configuration (TSxx unit type)

from the HW Configurator.

2. Ensure that the unit types of the IDD TSxx units are correct

(EDGE-capable unit, TSxB).

Fault reason: TRX is stuck in waiting for system information state.

Instructions:

1. Reset the TRX/sector.

Note: Do not replace the TSxx unit.

Fault reason: FBUS HW failure.

Instructions:

1. Reset the sector.

2. Replace the BB2x units one by one.

Fault reason: The transmitter output of TRX is overdriven.

Instructions:

1. Replace the TSxx.

Fault reason: The transmitter output power has dropped at least 3 dB.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Fault reason: The transmitter output power is too low.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Fault reason: Fault in RF module transmitter interface.

Instructions:

670 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 671: Alarm

1. Replace the TSxx.

Fault reason: Fault in RF module receiver interface.

Instructions:

1. Replace the TSxx.

Fault reason: RF module initialization has failed.

Instructions:

1. Replace the TSxx.

Fault reason: Internal DSP and RF module communication failure in

TRX.

Instructions:

1. Reset the sector.

2. Replace the BB2x.

3. If the fault still exists, replace the TSxx.

Fault reason: The RF transmitter synthesizer is not locked.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Fault reason: The RF transmitter frequency hopping

synthesizer 1 is not locked.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Fault reason: The RF transmitter frequency hopping

synthesizer 2 is not locked.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Fault reason: The RF receiver synthesizer is not locked.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Fault reason: The RF receiver frequency hopping

synthesizer 1 is not locked.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Fault reason: The RF receiver frequency hopping

synthesizer 2 is not locked.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Other fault reasons

Instructions:

See the Alarm Descriptions document included in the BTS SW release

binder of the alarming base station type.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 671 (1095)

7606 TRX FAULTY

Page 672: Alarm

FLEXI EDGE:

Fault reason: Hardware incompatibility detected during EXxx TRX

module configuring.

Description: Frequency band/channel or BTS configuration mismatch

between the BTS units and BSC configuration.

Instructions:

1. Check that the EXxx, ECxx/ERxx module is of correct frequency

(sub-)band as configured in the BSC.

2. Check that RF hopping is not used when ECxx is installed.

3. Modify BSC parameters against the actual configuration at the

site.

4. Replace EXxx or ERxx/ECxx.

Fault reason: EXxx TRX module has no combiner ERxx DDU or ECxx RTC

module present.

Description: There is no ERxx DDU module or ECxx RTC module detected

for the sector at start up.

Instructions:

1. Depending on the desired configuration:

a. Connect/check ER_A cable between Erxx and EXxx for the

associated sector and issue a sector reset. OR

b. Connect/check bus cable between ECxx and ESMA and issue a

sector reset.

2. Replace ERxx/ECxx.

3. Replace EXxx.

Fault reason: EXxx TRX module incoming frame clock FCLK missing.

Description: EXxx TRX module has detected that the Frame Clock coming

from the ESMA System module is missing. FCLK is generated by ESMA

System module which is distributed to EXxx TRX modules either

directly

or via ESEA.

Instructions:

1. Check the bus cable chain from ESMA to EXxx.

Caution

If bus cables are looped back to the same module, ongoing calls

may be dropped or a module may freeze until the loop is removed.

Do not loop bus cables back to the same module.

2. Replace EXxx.

3. Replace ESEA if alarming TRX is connected to it.

4. Replace ESMA.

Fault reason: EXxx TRX module failed to synchronize to incoming frame

clock FCLK.

Description: EXxx TRX module has detected that it cannot synchronise

to the Frame Clock. FCLK is generated by ESMA System module which is

distributed to EXxx TRX modules either directly or via ESEA.

1. Check the bus cable chain from ESMA to EXxx. Issue a HW Reset

to EXxx.

Caution

If bus cables are looped back to the same module, ongoing calls

may be dropped or a module may freeze until the loop is removed.

Do not loop bus cables back to the same module.

2. Replace EXxx.

3. Replace ESMA.

4. Replace ESEA.

672 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 673: Alarm

Fault reason: EXxx TRX module incoming 6.5 MHz reference clock

missing.

Description: EXxx TRX module has detected that the 6.5 MHz reference

clock coming from the ESMA System module is missing. The 6.5 MHz

reference is generated by ESMA System module which is distributed to

EXxx TRX modules either directly or via ESEA.

Instructions:

1. Check the bus cable chain from ESMA to EXxx.

Caution

If bus cables are looped back to the same module, ongoing calls

may be dropped or a module may freeze until the loop is removed.

Do not loop bus cables back to the same module.

2. Replace EXxx.

3. Replace ESEA if alarming TRX is connected to it.

4. Replace ESMA.

Fault reason: EXxx TRX module temperature dangerously high.

Description: EXxx TRX module has detected that its internal

temperature has exceeded +95C/+203F.

Instructions:

1. Ensure that the ambient temperature of the base station

is below +50C/+122F

2. Check if any fan alarms are also active. If active, refer

to fan alarm instructions to resolve.

3. Replace the EXxx.

Fault reason: Internal failure occurred during EXxx TRX module

configuring.

Description: There was no internal response or timeout occurred

during EXxx

TRX module configuration.

Instructions:

1. Reset the EXxx to allow unit reconfiguration.

2. If alarm persists, replace EXxx.

Fault reason: ERxx DDU module SW activation fails.

Description: ERxx DDU module did not activate inactive SW and

therefore it is running with current active package.

1. Issue a HW reset to EXxx.

2. If alarm reappears after ERxx SW download, replace ERxx.

Fault reason:

ERxx DDU module not supported.

Description: Connected module is either of wrong network type or

device type.

Instructions:

1. Check that the connected ERxx is of correct frequency band in

respect to the used EXxx.

2. Check that ERxx is connected to EXxx.

3. Replace ERxx.

Fault reason: ERxx DDU module reported HW failure.

Description: At startup ERxx DDU module reported internal HW failure.

Instructions:

1. Replace ERxx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 673 (1095)

7606 TRX FAULTY

Page 674: Alarm

Fault reason: ESMA System module has lost connection to EXxx TRX

module.

Description: EXxx TRX or ECxx RTC module does not respond to polling

command from ESMA System module. EXxx TRX module can be connected to

ESMA either directly or via ESEA System Extension module.

Instructions:

DTRX Case:

1. Check the bus cable chain from ESMA to EXxx.

Caution

If bus cables are looped back to the same module, ongoing calls

may be dropped or a module may freeze until the loop is removed.

Do not loop bus cables back to the same module.

2. If the EXxx LED is off, replace the power cable.

3. Replace EXxx.

4. Replace ESEA if alarming TRX is connected to it.

5. Replace ESMA.

RTC Case:

1. Check the bus cable chain from ESMA to ECxx.

Caution

If bus cables are looped back to the same module, ongoing calls

may be dropped or a module may freeze until the loop is removed.

Do not loop bus cables back to the same module.

2. If the ECxx LED is off, replace the power cable.

3. Replace ECxx.

4. Replace ESMA.

Fault reason: EXxx TRX module has lost connection to ERxx DDU module.

Description: ERxx DDU module is not responding to poll command from

EXxx TRX module.

Instructions:

1. Check that the ER_A cable is correctly mated between EXxx

and ERxx.

2. Replace ERxx.

3. Replace EXxx.

Fault reason: Internal failure occurred during ERxx DDU module

configuring.

Description: ERxx DDU module configuration (Gain or Bias-T) failed.

Instructions:

1. Reset the EXxx to allow ERxx unit reconfiguration.

2. If the alarm reappears, replace ERxx.

Fault reason: EXxx TRX module has missing transmission time slot

allocation.

Description: TRXsig and/or TCH allocation for EXxx TRX module is

missing the Abis allocation.

Instructions:

1. Check that BTS configuration and Abis time slot allocation

matches between the SCF, installed units and the BSC.

2. Add missing time slot allocation to the SCF/BTS by appending

the commissioning file.

Fault reason: EXxx TRX module SW download from ESMA System module

failed.

674 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 675: Alarm

Description: ESMA System Module detected that SW download to EXxx TRX

module has failed repeatedly at TRX startup. EXxx TRX module can be

connected to ESMA either directly or via ESEA System Extension

module.

Instructions:

1. Check the bus cable chain from ESMA to EXxx.

Caution

If bus cables are looped back to the same module, ongoing calls

may be dropped or a module may freeze until the loop is removed.

Do not loop bus cables back to the same module.

2. Replace EXxx.

Fault reason: ECxx RTC module internal HW failure.

Description: At startup ECxx RTC module reported internal HW failure.

Instructions:

1. Replace ECxx.

Fault reason: ECxx RTC module SW download from ESMA System module

failed.

Description: ESMA System Module detected that SW download to ECxx RTC

module has failed at startup.

Instructions:

1. Issue a HW reset to ESMA.

2. If alarm persists, replace ECxx.

3. Replace ESMA.

Fault reason: EXxx TRX module failed to synchronize to incoming frame

clock FCLK.

Description: ECxx RTC module has detected that the Frame Clock coming

from the ESMA System module is missing.

Instructions:

1. Issue a HW reset to ESMA.

2. Check that the bus cable is correctly mated between the ECxx

and ESMA.

Caution

If bus cables are looped back to the same module, ongoing calls

may be dropped or a module may freeze until the loop is removed.

Do not loop bus cables back to the same module.

3. Check whether other ECxx modules have the same alarm, replace

ESMA.

4. Replace ECxx.

Fault reason: ECxx RTC module received insufficient Tx power.

Description: ECxx RTC module detected insufficient power during

cavity tuning. RTC is unable to perform cavity tuning.

Instructions:

1. Issue a sector lock/unlock to allow ECxx RTC module

reconfiguration.

2. Check that the Tx cabling between EXxx and ECxx is correctly

mated. Check also the condition of cables.

3. If all the EXxx connected to the ECxx have raised this alarm,

replace ECxx.

4. Replace EXxx.

5. Replace ECxx.

Fault reason: EXxx TRX module Tx hopping synthesizer 1 fails to lock.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 675 (1095)

7606 TRX FAULTY

Page 676: Alarm

Description: Tx hopping synthesizer 1 in EXxx TRX module was unable

to (maintain) lock to the given channel.

Instructions:

1. Reset TRX/Sector.

2. Replace EXxx.

Fault reason: EXxx TRX module Tx hopping synthesizer 2 fails to lock.

Description: Tx hopping synthesizer 2 in EXxx TRX module was unable

to (maintain) lock to the given channel.

Instructions:

1. Reset TRX/Sector.

2. Replace EXxx.

Fault reason: EXxx TRX module Rx hopping synthesizer 1 fails to lock.

Description: Rx hopping synthesizer 1 in EXxx TRX module was unable

to (maintain) lock to the given channel.

Instructions:

1. Reset TRX/Sector.

2. Replace EXxx.

Fault reason: EXxx TRX module Rx hopping synthesizer 2 fails to lock.

Description: Rx hopping synthesizer 2 in EXxx TRX module was unable

to (maintain) lock to the given channel.

Instructions:

1. Reset TRX/Sector.

2. Replace EXxx.

Fault reason: EXxx TRX module Rx fixed frequency synthesizer fails to

lock.

Description: Rx fixed frequency synthesizer in EXxx TRX module was

unable to (maintain) lock to the given channel.

Instructions:

1. Reset TRX/Sector.

2. Replace EXxx.

Fault reason: EXxx TRX module Tx power is less than minimum at DPC.

Description: Tx output power is less than +14.5dBm at Digital Power

Control circuit block in EXxx TRX module.

Instructions:

1. Replace EXxx.

Fault reason: EXxx TRX module Tx power overdriven at DPC.

Description: Tx output power is over 2 dB higher than expected at

Digital Power Control circuit block in EXxx TRX module.

1. Replace EXxx.

Fault reason: EXxx TRX module detected no connection to ERxx DDU via

RF cable autodetection.

Description: RF cable autodetection failed due to no Tx or Rx

connectivity from EXxx TRX module to ERxx DDU module. All Rx

measurement report values for a TRX object were below connectivity

threshold.

Instructions:

1. Check that the Tx and Rx cables between EXxx, EWxx and ERxx or

ECxx are correctly mated and the connectors and cables are not

damaged. Issue a sector reset to restart RF cable

676 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 677: Alarm

autodetection.

2. Replace EXxx.

Fault reason: EXxx TRX module detected no Rx signal during RF cable

autodetection.

Description: RF cable autodetection failed due to no Rx connectivity

from EXxx TRX module to ECxx RTC module. All Rx measurement report

values for a TRX object were below connectivity threshold. When this

alarm is active, BTS Manager does not display any RF cabling.

Instructions:

1. Check that the Rx cables between EXxx and ECxx are correctly

mated with defined torque and the connectors are not damaged.

Issue a sector reset to restart RF cable autodetection.

2. Check that ECxx and EXxx are of same frequency band.

3. If all the EXxx connected to the ECxx have raised this alarm,

replace ECxx.

4. Replace EXxx.

Fault reason: Two or more ERxx DDU modules detected in 2- or 4- way

combined sector.

Description: RF cable autodetection detected that current combining

method does not allow more than one ERxx DDU module in a sector.

Instructions:

1. Check that the Tx cabling from EXxx and EWxx modules in one

sector are connected to the same ERxx module.

2. Remove extra ERxx from the sector.

Fault reason: ERxx DDU module has detected no Tx power at TxA input.

Description: There is no Tx power detected at TxA input of ERxx DDU

module.

Instructions:

1. Check the whole Tx cabling chain between EXxx, EWxx (upon

usage) and ERxx that they are correctly mated between the

units.

2. Check that the cables are not damaged or bent too sharply.

3. Replace EXxx.

4. Replace ECxx.

5. Replace EWxx.

Fault reason: ERxx DDU module has detected no Tx power at TxB input.

Description: There is no Tx power detected at TxB input of ERxx DDU

module.

Instructions:

1. Check the whole Tx cabling chain between EXxx, EWxx (upon

usage) and ERxx that they are correctly mated between the

units.

2. Check that the cables are not damaged or bent too sharply.

3. Replace EXxx.

4. Replace ECxx.

5. Replace EWxx.

Fault reason: ERxx DDU module has detected VSWR above major limit at

antenna A.

Description: User definable major alarm threshold for VSWR

measurement has been exceeded. The default value is 3.1.

Instructions:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 677 (1095)

7606 TRX FAULTY

Page 678: Alarm

1. Check the condition of the feeder and jumper cable, their

connectors, sockets and connector seals starting from BTS end

and proceed towards the antenna end. Replace damaged feeder

cable.

2. If MHA is used, check that it is of correct (sub) band.

3. With external test equipment, measure the Return loss/VSWR of

the antenna line. Perform step 1 again, if the measurement

result is higher than expected.

4. Revise the VSWR alarm threshold by appending the commissioning.

5. Replace ERxx.

Fault reason: ERxx DDU module has detected VSWR above major limit at

antenna B.

Description: User definable major alarm threshold for VSWR

measurement has been exceeded. The default value is 3.1.

Instructions:

1. Check the condition of the feeder and jumper cable, their

connectors, sockets and connector seals starting from BTS end

and proceed towards the antenna end. Replace damaged feeder

cable.

2. If MHA is used, check that it is of correct (sub) band.

3. With external test equipment, measure the Return loss/VSWR of

the antenna line. Perform step 1 again, if the measurement

result is higher than expected.

4. Revise the VSWR alarm threshold by appending the commissioning.

5. Replace ERxx.

Fault reason: ECxx RTC module has lost Tx power from all inputs.

Description: No Tx power detected from any of the TRXs connected to

ECxx RTC module. Note: This alarm might take up to one hour to appear

after RTC module is reset.

Instructions:

1. Issue a sector reset and run a TRX test for each TRX.

2. Check the Tx cabling from all the TRXs and issue a sector

reset. Run a TRX test for each TRX.

3. If the alarm persists, replace ECxx.

Fault reason: ECxx RTC module has detected VSWR above major limit at

antenna.

Description: User definable major alarm threshold for VSWR

measurement has been exceeded. The default value is 3.1.

Instructions:

1. Check the condition of the feeder and jumper cable, their

connectors, sockets and connector seals starting from BTS end

and proceed towards the antenna end. Replace damaged feeder

cable.

2. If MHA is used, check that is of correct (sub)band.

3. With external test equipment, measure the Return loss/VSWR of

the antenna line. Perform step 1 again, if the measurement

result is higher than expected.

4. Revise the VSWR alarm threshold by appending the commissioning.

5. Replace ECxx.

Fault reason: Main Rx LNA amplifier chain is broken in ECxx RTC

module.

Description: Both low noise amplifiers in a balanced stage have

678 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 679: Alarm

failed for the main branch of the ECxx RTC module. The diversity

branch is either not configured or it is broken.

Instructions:

1. Replace ECxx.

Fault reason: ECxx RTC module has detected that MHA on ANT A is

broken.

Description: Measured current consumption of Mast Head Amplifier has

either exceeded the upper limit or dropped below the lower limit. MHA

bypass is not configured/equipped. The upper and lower limits are

user definable during commissioning.

Instructions:

1. Check that the current min/max limits and MHA settings

correspond to the actual configuration.

2. Check the antenna line for any damage affecting the current

supply to the MHA.

3. Replace MHA.

4. Replace ECxx.

Fault reason: ECxx RTC module has detected that MHA on ANT B is

broken.

Description: Measured current consumption of Mast Head Amplifier has

either exceeded the upper limit or dropped below the lower limit. MHA

bypass is not configured/equipped. The upper and lower limits are

user definable during commissioning.

Instructions:

1. Check that the current min/max limits and MHA settings

correspond to the actual configuration.

2. Check the antenna line for any damage affecting the current

supply to the MHA.

3. Replace MHA.

4. Replace ECxx.

Fault reason: ECxx RTC module has detected no Tx power during RF cable

autodetection.

Description: RF cable autodetection failed due to no Tx connectivity

from EXxx TRX module to ECxx RTC module.

Instructions:

1. Check that the Tx and Rx cables between EXxx and ECxx are

correctly mated and the connectors and cables are not damaged.

Issue a sector reset from EM to restart RF cable autodetection.

2. Check that ECxx and EXxx are of same frequency band.

3. Check that bus cable and internal power cable is correctly

mated between ECxx and ESMA.

4. If all the EXxx connected to the ECxx have raised this alarm,

replace ECxx.

5. Replace EXxx.

6. Replace ECxx.

Fault reason: XEOCA Optical module detected extreme temperature

Description: EOCA Optical module has detected that its internal

temperature has exceeded +90C/+194F.

Instructions:

1. Ensure that the ambient temperature of the base station is

below +50C/+122F.

2. Check if any fan alarm is also active. If active, refer to fan

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 679 (1095)

7606 TRX FAULTY

Page 680: Alarm

alarm instructions to resolve.

3. Replace the alarming EOCA.

Fault reason: XEOCA optical module reported incoming clock failure

Description: Incoming clock errors or optical link failures either in

Local or Remote EOCA Optical module.

Instructions:

1. If on Local EOCA

1.1 Check the bus cable, the connectors or replace the cable

between ESxx and Local EOCA.

1.2 Check optical transceiver plug-in unit of Local EOCA.

1.3 Replace Local EOCA.

1.4 Check optical transceiver plug-in unit of Remote EOCA.

1.5 Replace Remote EOCA.

1.6 Check the optical cable and its connector(s) and replace

cable in case faulty.

2. If on Remote EOCA

2.1 Check optical transceiver plug-in unit of Local EOCA.

2.2 Replace Local EOCA.

2.3 Check optical transceiver plug-in unit of Remote EOCA.

2.4 Replace Remote EOCA.

2.5 Check the optical cable and its connector(s) and replace

cable in case faulty.

Fault reason: XEOCA Optical module reported HW failure

Description: ESMA System module detected that hardware failure has

occurred in EOCA Optical module at startup.

Instructions:

1. If on Local EOCA

1.1 Replace Local EOCA.

2. If on Remote EOCA

2.1 Replace Remote EOCA.

Cancelling

METROSITE and ULTRASITE:

This is a start/cancel type alarm.

For the fault reasons :

"Antenna connection faulty." and

"TRX test result antenna connection faulty."

alarm is cancelled automatically (object reset) or manually

(TRX test).

For the fault reason :

"Fault in VSWR antenna monitoring."

alarm is cancelled manually (sector reset).

For other fault reasons alarm is cancelled automatically.

In UltraSite base stations the alarm has to be

cancelled manually if baseband hopping is used.

Flexi EDGE:

If the fault reason "Internal failure occurred during EXxx TRX module

configuring" occurs, the alarm is TRX unlock/lock type. You have to

cancel the alarm manually.

680 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 681: Alarm

If the fault reason is one of the following:

- "ERxx DDU module has detected no Tx power at TxA input"

- "ERxx DDU module has detected no Tx power at TxB input"

- "ECxx RTC module has detected VSWR above major limit at antenna"

the alarm is Sector unlock/lock type and you have to cancel the alarm

manually.

If the fault reason is one of the following:

- "EXxx TRX module has no combiner ERxx DDU or ECxx RTC module

present"

- "EXxx TRX module failed to synchronize to incoming frame clock

FCLK"

- "ERxx DDU module SW activation fails."

- "ERxx DDU module not supported"

- "ERxx DDU module reported HW failure."

- "Internal failure occurred during ERxx DDU module configuring"

- "EXxx TRX module Tx hopping synthesizer 1 fails to lock"

- "EXxx TRX module Tx hopping synthesizer 2 fails to lock"

- "EXxx TRX module Rx hopping synthesizer 1 fails to lock"

- "EXxx TRX module Rx fixed frequency synthesizer fails to lock"

- "EXxx TRX module Tx power is less than minimum at DPC"

- "EXxx TRX module Tx power overdriven at DPC"

- "EXxx TRX module detected no connection to ERxx DDU via RF cable

autodetection"

- "EXxx TRX module detected no Rx signal during RF cable

autodetection"

- "Two or more ERxx DDU modules detected in 2- or 4- way combined

sector"

- "ERxx DDU module has detected VSWR above major limit at antenna A"

- "ERxx DDU module has detected VSWR above major limit at antenna B"

- "ECxx RTC module has lost Tx power from all inputs"

- "Main Rx LNA amplifier chain is broken in ECxx RTC module"

- "ECxx RTC module has detected that MHA on ANT A is broken"

- "ECxx RTC module has detected that MHA on ANT B is broken"

- "ECxx RTC module has detected no Tx power during RF cable

autodetection"

- "XEOCA optical module reported incoming clock failure"

- "XEOCA Optical module reported HW failure",

you have to cancel the alarm manually.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 681 (1095)

7606 TRX FAULTY

Page 682: Alarm

682 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 683: Alarm

3137607 TRX OPERATION DEGRADED

Meaning

Critical fault has occurred in a TRX.

The fault reason can be read from the supplementary text field

of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason: Diversity branch FBUS HW failure.

Instructions:

1. Reset the IDD main TRX.

Note: This alarm is related to auxiliary TRX. This alarm

may appear when the IDD auxiliary TRX is reset.

Fault reason: IDD main/auxiliary TRX frequency band mismatch.

Instructions:

1. Check the IDD configuration (TRX frequency band)

from the BTS Manager.

2. Ensure that the frequency band of the IDD TRX units is correct.

3. Replace the IDD auxiliary TRX with one of the same

frequency as the IDD main TRX unit.

Note: The TRX units used for an IDD pair must be of the

same type.

Fault reason: Mismatch between BSC/MMI configuration and/or IDD TRX.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 683 (1095)

7607 TRX OPERATION DEGRADED

Page 684: Alarm

Instructions:

1. Delete the IDD auxiliary TRX from the BSC configuration.

2. Reset the IDD main TRX.

Note: This alarm is related to auxiliary TRX. IDD

auxiliary TRXs are not to be defined at the BSC.

Fault reason: Non EDGE TRX device type used accidentally in IDD mode.

Instructions:

1. Check the IDD configuration of the BCF.

2. Check the configuration of the TRX.

3. Replace the IDD auxiliary TRX with an EDGE capable unit.

Note: This alarm is related to auxiliary TRX. IDD TRXs

must be EDGE capable.

Other fault reasons

Instructions:

See the Alarm Descriptions document included in the BTS SW

release binder of the alarming base station type.

ULTRASITE:

Fault reason: Flash operation failed in BOI or TRX.

Instructions:

1. Replace the BB2x.

Fault reason: The remote tune combiner controller is faulty.

Instructions:

1. Replace the RTxx.

Fault reason: The reflected power of remote tune combiner is too high.

Instructions:

1. Check the antenna connection to the remote tune combiner.

2. If the antenna connection is OK, replace the remote tune combiner.

Diversity branch is still working and calls are getting through.

Fault reason: LNA main branch in remote tune combiner is faulty.

Instructions:

1. Replace the RTxx.

Diversity branch is still working and calls are

getting through.

Fault reason: LNA diversity branch in remote tune combiner is faulty.

Instructions:

1. Replace the RTxx.

Main branch is still working and calls are

getting through.

Fault reason: The synthesizer in remote tune combiner is faulty.

Instructions:

1. Replace the RTxx.

Diversity branch is still working and calls are

getting through.

Fault reason: The controller is out of order in remote tune combiner.

Instructions:

1. Replace the RTxx.

Diversity branch is still working and calls are

684 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 685: Alarm

getting through.

Fault reason: Performance of the main branch LNA in remote tune

combiner is degraded.

Instructions:

1. Replace the RTxx.

Diversity branch is still working and calls are

getting through.

Fault reason: Performance of the main diversity LNA in remote tune

combiner is degraded.

Instructions:

1. Replace the RTxx.

Main branch is still working and calls are

getting through.

Fault reason: 1st branch LNA in dual variable gain duplex unit

is faulty.

Instructions:

1. Replace the DVxx.

2nd branch is still working and calls are getting through.

Fault reason: 2nd branch LNA in dual variable gain duplex unit

is faulty.

Instructions:

1. Replace the DVxx.

1st branch is still working and calls are getting through.

Fault reason: Performance of the 1st branch LNA in dual

variable gain duplex unit is degraded.

Instructions:

1. Replace the DVxx.

2nd branch is still working and calls are getting through.

Fault reason: Performance of the 2nd branch LNA in dual

variable gain duplex unit is degraded.

Instructions:

1. Replace the DVxx.

1st branch is still working and calls are getting through.

Fault reason : No connection to dual variable gain duplex unit.

Instructions:

1. Check the BTS configuration and install the DVxx if it

is missing from the configuration.

2. Check the cable connection between the backplane

and the DVxx unit.

3. Replace the DVxx.

Fault reason : Fault in the chain between power unit and MHA.

Instructions:

1. Check the voltage supply chain between the PWSx

unit(s) and the MHA.

2. Replace the PWSx.

3. Replace the Bias-T.

4. Replace the MHA.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 685 (1095)

7607 TRX OPERATION DEGRADED

Page 686: Alarm

Fault reason: Fault in the chain between power unit and

high gain MNxx with bypass

Instructions:

1. Check the Antenna Properties in the HW configuration file.

2. Check the antenna cabling.

3. Check the Bias-T and the cabling between the Bias-T

and the Interface board on the top side of the cabinet.

4. Check the interface board.

5. Check the PWSx unit.

6. Replace the MNxx.

Fault reason: Fault in VSWR antenna monitoring.

Instructions:

1. Check the antenna line and the Bias-T cabling. Reset the sector.

2. Check all RF cabling between the TSxx's TX output connector

and top of the cabinet (including WCDx and DVxx or RTxx units).

3. Replace the Bias-T.

4. Replace the TSxx.

Note: Diversity RX branch is still working and calls are

getting through.

Fault reason: TRX is unable to implement EDGE services.

Instructions:

1. Check the configuration of TRXs.

2. Upgrade the TSxx/BB2x units to EDGE capability.

Fault reason: IDD main/auxiliary TRX frequency band mismatch.

Instructions:

1. Check the IDD configuration (TSxx frequency band) from the

HW Configurator.

2. Ensure that the frequency band of the IDD TSxx units is correct.

3. Replace the IDD auxiliary TSxx with one of the same frequency

as the IDD main TSxx unit.

Note: The TSxx units used for an IDD pair must be of

the same type.

Fault reason: Mismatch between BSC/MMI configuration and/or IDD TRX.

Instructions:

1. Delete the IDD auxiliary TRX from the BSC configuration.

2. Reset the IDD main TRX.

Note: This alarm is related to auxiliary TRX. IDD

auxiliary TRXs are not to be defined at the BSC.

Fault reason: Non EDGE TRX device type used accidentally in IDD mode.

Instructions:

1. Check the IDD configuration of the BCF.

2. Check the configuration of the TRX.

3. Replace the IDD auxiliary TSxx with an EDGE capable unit.

Note: This alarm is related to auxiliary TRX. IDD TRXs

must be EDGE capable.

Fault reason: Diversity branch runtime loop failure between

CHDSP and EQDSP via Fbus.

Instructions:

1. Reset the TRX (lock/unlock).

2. If the alarm reappears, reset the IDD main TRX.

686 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 687: Alarm

3. Replace the BB2E unit.

Note: This alarm is related to auxiliary TRX. This alarm

may appear when the IDD auxiliary TRX is reset.

Fault reason: Diversity branch FBUS HW failure.

Instructions:

1. Reset the IDD main TRX.

2. Replace the BB2E/F unit.

Note: This alarm is related to auxiliary TRX. This alarm

may appear when the IDD auxiliary TRX is reset.

Fault reason: The transmitter output power has dropped at least 3 dB.

Instructions:

1. Reset the TRX/sector.

2. Replace the TSxx.

Note: This is the last partly working TRX in the sector,

service has degraded.

Other fault reasons :

Instructions:

See the Alarm Descriptions document included in the BTS SW

release binder of the alarming base station type.

Flexi EDGE:

Fault reason: Path A of Rx LNA amplifier chain is broken in ERxx DDU

module.

Description: Both low noise amplifiers in a balanced stage have failed

for Path A of ERxx DDU module. If diversity is used, Path B is still

working.

Instructions:

1. Replace ERxx.

Fault reason: Path B of Rx LNA amplifier chain is broken in ERxx DDU

module.

Description: Both low noise amplifiers in a balanced stage have failed

for Path B of ERxx DDU module. If diversity is used, Path A is still

working.

Instructions:

1. Replace ERxx.

Fault reason: Path A of Rx LNA amplifier chain is broken in ECxx RTC

module.

Description: Both low noise amplifiers in a balanced stage have failed

for main branch of ECxx RTC module. If diversity is used, the diversity

branch is still working.

Instructions:

1. Replace ECxx.

Fault reason: Path B of Rx LNA amplifier chain is broken in ECxx RTC

module.

Description: Both low noise amplifiers in a balanced stage have failed

for diversity branch of ECxx RTC module. The main branch is still

working.

Instructions:

1. Replace ECxx.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 687 (1095)

7607 TRX OPERATION DEGRADED

Page 688: Alarm

Fault reason: ERxx DDU module has detected that MHA on its antenna A

is broken.

Description: Measured current consumption of Mast Head Amplifier has

either exceeded the upper limit or dropped below the lower limit. MHA

bypass is not configured/equipped. The upper and lower limits are user

definable during commissioning.

Instructions:

1. Check that the current min/max limits and MHA settings correspond

to the actual configuration.

2. Check the antenna line for any damage affecting the current supply

to the MHA.

3. Replace MHA.

4. Replace ERxx.

Fault reason: ERxx DDU module has detected that MHA on its antenna B is

broken.

Description: Measured current consumption of Mast Head Amplifier has

either exceeded the upper limit or dropped below the lower limit. MHA

bypass is not configured/equipped. The upper and lower limits are user

definable during commissioning.

Instructions:

1. Check that the current min/max limits and MHA settings correspond

to the actual configuration.

2. Check the antenna line for any damage affecting the current supply

to the MHA.

3. Replace MHA.

4. Replace ERxx.

Fault reason: ECxx RTC module has detected that MHA on its antenna A is

broken.

Description: Measured current consumption of Mast Head Amplifier has

either exceeded the upper limit or dropped below the lower limit. MHA

bypass is not configured/equipped. The upper and lower limits are user

definable during commissioning. If diversity is used, diversity antenna

is still working.

Instructions:

1. Check that the current min/max limits and MHA settings correspond

to the actual configuration.

2. Check the antenna line for any damage affecting the current

supply to the MHA.

3. Replace MHA.

4. Replace ECxx.

Fault reason: ECxx RTC module has detected that MHA on its antenna B is

broken.

Description: Measured current consumption of Mast Head Amplifier has

either exceeded the upper limit or dropped below the lower limit. MHA

bypass is not configured/equipped. The upper and lower limits are user

definable during commissioning. Main antenna is still working.

Instructions:

1. Check that the current min/max limits and MHA settings correspond

to the actual configuration.

2. Check the antenna line for any damage affecting the current supply

to the MHA.

3. Replace MHA.

4. Replace ECxx.

688 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 689: Alarm

Fault reason: Frequency band mismatch between commissioning file and

detected hardware.

Description: Mismatch between User specified Receiver Band in MHA

information and actual network type of ECxx RTC module / ERxx DDU

module.

Instructions:

1. Modify MHA information of antenna settings in the Site

Commissioning file according to the actual HW configuration.

2. Replace the ECxx/ERxx module to correspond to the MHA information

of antenna settings in the Site Commissioning file.

Fault reason: EXxx TRX module cooling fan(s) report no rotation.

Description: One or more fans of the EXxx TRX module are not rotating.

There is a danger of overheating.

Instructions:

1. Check that the fan unit cable is correctly mated to EXxx.

2. Check that there are no obstacles preventing the fan(s) from

rotating.

3. Clean the fan unit of dust and/or dirt.

4. Replace the fan unit.

5. Replace EXxx.

Fault reason: One amplifier stage of Rx LNA Path A is broken in ERxx

DDU module.

Description: One of the two low noise amplifiers in balanced stage

failed in Path A of ERxx DDU module.

Instructions:

1. Replace ERxx.

Fault reason: One amplifier stage of Rx LNA Path B is broken in ERxx

DDU module. Description: One of the two low noise amplifiers in balanced

stage failed in Path B of ERxx DDU module.

1. Replace ERxx.

Fault reason: Current used by MHA is out of range for ERxx DDU module

(antenna A bypassed).

Description: Measured current consumption of Mast Head Amplifier has

exceeded min or max threshold indicating broken amplifier. MHA is using its

bypass circuit and antenna feeder cable loss is not compensated.

Instructions:

1. Check that the current min/max limits and MHA settings correspond to

the actual configuration.

2. Check the antenna line for any damage affecting the current supply

to the MHA.

3. Replace MHA.

4. Replace ERxx.

Fault reason: Current used by MHA is out of range for ERxx DDU module

(antenna B bypassed).

Description: Measured current consumption of Mast Head Amplifier has

exceeded min or max threshold indicating broken amplifier. MHA is using

its bypass circuit and antenna feeder cable loss is not compensated.

Instructions:

1. Check that the current min/max limits and MHA settings correspond

to the actual configuration.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 689 (1095)

7607 TRX OPERATION DEGRADED

Page 690: Alarm

2. Check the antenna line for any damage affecting the current supply

to the MHA.

3. Replace MHA.

4. Replace ERxx.

Fault reason: ERxx DDU module SW upgrade failed.

Description: SW upgrade is aborted due to negative acknowledgement from

ERxx DDU module during sw download.

Instructions:

1. Issue a HW reset to ESMA.

2. If the alarm persists, replace ERxx.

Fault reason: ECxx RTC module cavity tuning synthesizer faulty.

Description: Tuning is only predicted. The cavities are not fine tuned.

ECxx RTC module tries to fine tune the cavities periodically. After

successful fine tuning the alarm is cancelled.

Instructions:

1. Issue a sector lock/unlock to allow ECxx reconfiguration.

2. Replace ECxx.

Fault reason: Current used by MHA is out of range for ECxx RTC module

(antenna B bypassed).

Description: Measured current consumption of Mast Head Amplifier has

exceeded min or max threshold indicating broken amplifier. MHA is using

its bypass circuit and antenna feeder cable loss is not compensated.

Instructions:

1. Check that the current min/max limits and MHA settings correspond

to the actual configuration.

2. Check the antenna line for any damage affecting the current supply

to the MHA.

3. Replace MHA.

4. Replace ECxx.

Fault reason: One amplifier stage of Rx LNA Path A is broken in ECxx RTC

module.

Description: One of the two low noise amplifiers in balanced stage failed

in Path A of ECxx RTC module.

Instructions:

1. Replace ECxx.

Fault reason: One amplifier stage of Rx LNA Path B is broken in ECxx RTC

module.

Description: One of the two low noise amplifiers in balanced stage failed

in Path B of ECxx RTC module.

Instructions:

1. Replace ECxx.

Fault reason: Commissioning file climate control profile mismatch, no fans

detected.

Description: Climate control profile indicates an installed fan unit but

it is missing from the actual configuration. There is a danger of

overheating.

Instructions:

1. If none of the modules at the site require fan units, change the

fan profile to "No Fans" in the SCF and recommission the site.

2. Check that the fan unit cable is correctly mated to EXxx.

690 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 691: Alarm

3. Replace the fan unit.

4. Replace the EXxx.

Fault reason: Current used by MHA is out of range for ECxx RTC module

(antenna A bypassed).

Description: Measured current consumption of Mast Head Amplifier has

exceeded min or max threshold indicating broken amplifier. MHA is using

its bypass circuit and antenna feeder cable loss is not compensated.

Instructions:

1. Check that the current min/max limits and MHA settings correspond

to the actual configuration.

2. Check the antenna line for any damage affecting the current supply

to the MHA.

3. Replace MHA.

4. Replace ECxx.

Fault reason: EXxx TRX module Tx power is at least 3dB less than expected

at DPC.

Description: Tx output power is over 3 dB lower than expected at Digital

Power Control circuit block in EXxx TRX module.

Instructions:

1. Reset TRX/Sector.

2. Replace EXxx.

Fault reason: EXxx TRX module detected only one Rx signal during RF cable

autodetection.

Description: RF cable autodetection found Rx signal missing from the

sector where Rx diversity is being used.

Instructions:

1. Check that the Rx cabling between EXxx and ERxx are correctly

mated. Check the condition of cables and connectors. Issue a sector

reset.

2. Recommission the site with manual cabling, if Rx diversity is not to

be used.

3. Replace ERxx.

4. Replace EXxx.

Fault reason: RF cable autodetection found mixed (bypass/2-/4-way) Tx

combining in a sector.

Description: During RF cable autodetection, Tx combining is found to be

imbalanced. The Rx measurement value differences between any of the two

carriers in the sector is more than 2.5 dB.

Instructions:

1. Check that the ERxx has equal number of EWxx modules in both Tx

paths in 2-/4-way combined configuration. Issue a sector reset.

2. Check that the Tx cabling is correctly mated between units. Check

the condition of cables and connectors. Issue a sector reset.

3. Replace EWxx.

4. Replace EXxx.

5. Replace ERxx.

Fault reason: RSSI detected Rx signal difference exceeding threshold.

Description: The difference limit of Received Signal Strength Indicator

measurement has exceeded between the main and diversity antennas.

Instructions:

1. Check RSSI results with BTS Manager which antenna appears to have

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 691 (1095)

7607 TRX OPERATION DEGRADED

Page 692: Alarm

abnormal values. If abnormal values are lower than values from

other antennas, it indicates a disconnected or faulty cable in the

loop or a faulty LNA. If abnormal values are higher than values

from other antennas, it indicates interference coming outside of

the BTS or a faulty cable/module.

2. Check the RF cables and connections.

3. Check that the RXDL parameter at the BSC is set to a reasonable

value, taking into account the site condition in order to prevent

unnecessary alarms.

4. Check and measure the antenna lines.

5. Check the antenna alignment.

6. Replace ERxx.

7. Replace EXxx.

Fault reason: TRX objects of an EXxx TRX module are illegally split

between 2 sectors.

Description: TRX objects of one EXxx module are split into two different

sectors when Rx diversity is in use.

Instructions:

1. Revise the RF cabling according to the actual configuration

required (SCF/BSC). Issue a BCF reset to allow restart of RF cable

autodetection.

2. If the target is to split TRX objects across sectors, perform

recommissioning and manually specify the cabling including the

split.

Fault reason: ERxx DDU module has detected VSWR above minor limit at

antenna A.

Description: User definable minor alarm treshold for VSWR measurement has

been exceeded. The default value is 2.1.

Instructions:

1. Check the condition of the feeder and jumper cable, their

connectors, sockets and connector seals starting from BTS end and

proceed towards the antenna end. Replace damaged feeder cable.

2. If MHA is used, check that it is of correct (sub)band.

3. With external test equipment, measure the Return loss/VSWR of the

antenna line. Perform step 1 again, if the measurement result is

higher than expected.

4. Revise the VSWR alarm threshold by appending the commissioning.

5. Replace ERxx.

Fault reason: ERxx DDU module has detected VSWR above minor limit at

antenna B.

Description: User definable minor alarm threshold for VSWR measurement

has been exceeded. The default value is 2.1.

Instructions:

1. Check the condition of the feeder and jumper cable, their

connectors, sockets and connector seals starting from BTS end and

proceed towards the antenna end. Replace damaged feeder cable.

2. If MHA is used, check that it is of correct (sub)band.

3. With external test equipment, measure the Return loss/VSWR of the

antenna line. Perform step 1 again, if the measurement result is

higher than expected.

4. Revise the VSWR alarm threshold by appending the commissioning.

5. Replace ERxx.

692 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 693: Alarm

Fault reason: ECxx RTC module has detected VSWR above minor limit at

antenna.

Description: User definable minor alarm threshold for VSWR measurement

has been exceeded. The default value is 2.1.

Instructions:

1. Check the condition of the feeder and jumper cable, their

connectors, sockets and connector seals starting from BTS end and

proceed towards the antenna end. Replace damaged feeder cable.

2. If MHA is used, check that it is of correct (sub)band.

3. With external test equipment, measure the Return loss/VSWR of the

antenna line. Perform step 1 again, if the measurement result is

higher than expected.

4. Revise the VSWR alarm threshold by appending the commissioning.

5. Replace ECxx.

Fault reason: ECxx RTC module temperature dangerously high.

Description: ECxx RTC module has detected that its internal temperature has

exceeded +65C/+149F.

Instructions:

1. Ensure that the ambient temperature of the base station is below

+50C/+122F.

2. Check if any fan alarms are also active. If active, refer to fan

alarm instructions to resolve.

3. Replace the ECxx.

Fault reason: ECxx RTC module cooling fan(s) report no rotation.

Description: One or more fans of the ECxx RTC module are not rotating. There

is a danger of overheating.

Instructions:

1. Check that the fan unit cable is correctly mated to ECxx.

2. Check that there are no obstacles preventing the fan(s) from

rotating.

3. Clean the fan unit of dust and/or dirt.

4. Replace the fan unit.

5. Replace ECxx.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

The following exceptions apply to Flexi EDGE:

The cancellation of the following alarms is conditional:

- "ERxx DDU module has detected that MHA on its antenna A is broken"

- "ERxx DDU module has detected that MHA on its antenna B is broken"

- "ECxx RTC module has detected that MHA on its antenna A is broken"

- "ECxx RTC module has detected that MHA on its antenna B is broken"

The above-mentioned alarms are cancelled automatically if the current

consuption returns back within defined limites and has not exceeded 1A

at any point. If the current consuption exceeded 1A because Bias-T

supply is switched off to prevent damage, you have to cancel the alarm

manually. The alarm is cancelled via Sector lock/unlock.

If the fault reason "Commissioning file climate control profile

mismatch, no fans detected" occurs, the alarm is cancelled

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 693 (1095)

7607 TRX OPERATION DEGRADED

Page 694: Alarm

automatically only if the Site is commissioned with "no fans climate

control profile". Otherwise you have to cancel the alarm manually.

If any of the following fault reasons occur, you have to cancel the

alarm manually:

- "Current used by MHA is out of range for ERxx DDU module (antenna A

bypassed)"

- "Current used by MHA is out of range for ERxx DDU module (antenna B

bypassed)"

- "ERxx DDU module SW upgrade failed. SW upgrade is aborted due to

negative acknowledgement from ERxx DDU module during sw download"

- "Current used by MHA is out of range for ECxx RTC module (antenna B

bypassed)"

- "Current used by MHA is out of range for ECxx RTC module (antenna A

bypassed)"

- "EXxx TRX module Tx power is at least 3dB less than expected at DPC"

- "EXxx TRX module detected only one Rx signal during RF cable

autodetection"

- "RF cable autodetection found mixed (bypass/2-/4-way) Tx combining in

a sector

694 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 695: Alarm

3147608 TRX NOTIFICATION

Meaning

Minor fault has occurred in a TRX.

The fault reason can be read from the supplementary text field

of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

ULTRASITE:

Fault reason : TSxx internal I 2 C bus is jammed.

Instructions:

1. Reset the TRX.

2. If the fault reappears, replace the TSxx.

Fault reason : Impossible to execute TRX loop.

Instructions:

1. Reset the TRX.

2. If the fault reappears, replace the TSxx.

Fault reason : BB2 temperature is low.

Instructions:

1. Check the ambient temperature.

2. Check that the heater is working properly if equipped.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 695 (1095)

7608 TRX NOTIFICATION

Page 696: Alarm

3. If the temperature is OK, replace the BB2x.

Note: An alarm is activated when the BB2x unit internal

temperature is below -10C.

Fault reason : TSxx temperature is low.

Instructions:

1. Check the ambient temperature.

2. Check that the heater is working properly if equipped.

3. If the temperature is OK, replace the TSxx.

Note: An alarm is activated when the TSxx unit internal

temperature is below -10C.

Fault reason : BB2 has lost connection to temperature sensor.

Instructions:

1. Reset the TRX/sector.

2. Temperature sensor is probably broken.

Temperature changes cannot be measured. Replace the BB2x.

Fault reason : TSxx has lost connection to temperature sensor.

Instructions:

1. Reset the TRX/sector.

2. Temperature sensor is probably broken.

Temperature changes cannot be measured. Replace the TSxx.

Flexi EDGE:

Fault reason: EXxx TRX module temperature high.

Description: EXxx TRX module has detected that its internal temperature

has exceeded +90C/+194F.

Instructions:

1. Ensure that the ambient temperature of the base station is below

+50C/+122F.

2. Check if any fan alarms are also active. If active, refer to fan

alarm instructions to resolve.

3. Replace the EXxx.

Fault reason: ERxx DDU module SW upgrade impossible, unknown

manufacturer.

Description: EXxx TRX module cannot identify connected ERxx DDU

module. SW release incompatibility with connected HW.

Instructions:

1. Download and activate the latest release of the BTS SW to

ESMA System Module.

2. Replace ERxx.

Fault reason: EXxx TRX module cooling fan speed has deviated from the

set speed.

Description: There is more than 20% deviation in fan speed between

commanded and actual value.

Instructions:

1. Check that nothing obstructs the fan(s) from rotating.

2. Clean the fan unit of dust and/or dirt.

3. Replace the fan unit. Note: If "Temperature high/dangerously

high" and/or 7621 alarm(s) are also active, perform these actions

as soon as possible.

Fault reason: ERxx DDU module loop synthesizer fails to lock.

696 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 697: Alarm

Description: The RF loop synthesizer in ERxx DDU module has not achieved

phase lock state after several attempts.

Instructions:

1. Replace ERxx.

Fault reason: ECxx RTC module incoming frame clock FCLK lost during

runtime.

Description: RTC module has detected that the Frame Clock coming from

the ESMA System module is missing. Air3 loop services are unavailable.

Instructions:

1. Reset the BCF to allow ECxx to attempt resynchronisation to

incoming FCLK.

2. Replace ECxx.

3. If alarm is raised for all ECxx modules connected to ESMA, replace

ESMA.

Fault reason: EXxx TRX module unable to read internal temperature

sensors.

Description: There is no temperature measurement in the EXxx TRX module.

All temperature sensors inside the module are broken. Fans are rotating

at maximum speed.

Instructions:

1. Replace the EXxx. Note: If fan alarm(s) are active at EXxx,

perform this action as soon as possible.

Fault reason: ECxx RTC module loop synthesizer fails to lock.

Description: The RF loop synthesizer in ECxx RTC module has not achieved

phase lock state after several attempts.

Instructions:

1. Replace ECxx.

Fault reason: ESMA System module has lost connection to XEOCA Optical

module

Description: EOCA Optical module is not responding to ESMA System module.

Instructions:

1. If on Local EOCA

1.1 Check the bus cable, cable connectors between ESxx and Local

EOCA.

1.2 Replace Local EOCA.

2. If on Remote EOCA

2.1 Replace Remote EOCA.

Fault reason: XEOCA Optical module detected over current on its output

power port(s)

Description: Over current occured on the output power port(s) of Remote

EOCA

Optical module. Affected EXxx TRX module(s) are powered down.

Instructions:

1. Check the power cable between Remote EOCA and EXxx.

2. Replace EXxx.

3. Replace Remote EOCA.

Fault reason: Temperature inside XEOCA exceeds specified temperature

range

Description: Internal temperature of EOCA Optical module has exceeded

+85C/+185F.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 697 (1095)

7608 TRX NOTIFICATION

Page 698: Alarm

Instructions:

1. Ensure that the ambient temperature of the base station is below

+50C/+122F.

2. Check if fan alarm is also active. If active, refer to fan alarm

instructions to resolve.

3. Replace the alarming EOCA.

Fault reason: XEOCA Optical module detected temperature sensor problem

Description: There is no temperature measurement in the EOCA Optical

module. All temperature sensors inside the module are broken. Fan is

rotating at maximum speed.

Instructions:

1. Replace the alarming EOCA.

Note: If EOCA fan alarm is active, perform this action as soon

as possible.

Fault reason: XEOCA Optical module detected cooling fan speed degradation

Description: EOCA Optical module detected reduced or no rotation of fan

against commanded speed.

Instructions:

1. Check that nothing obstructs the fan from rotating.

2. Clean the fan unit of dust and/or dirt.

3. Replace the fan unit.

4. Replace the alarming EOCA.

Note: If temperature alarms are also active, perform these actions

as soon as possible.

Cancelling

This is a start/cancel type alarm. Alarm is cancelled automatically.

Flexi EDGE:

If the fault reason "ERxx DDU module SW upgrade impossible, unknown

manufacturer" occurs, you must cancel the alarm manually.

698 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 699: Alarm

3157609 TRE FAULTY

Meaning

Critical fault (or faults) that affects the transmission unit has

occurred.

This alarm blocks the transmission unit object.

The fault reason can be read from the supplementary text field

of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason : Master TRX detected that connection to transmission

unit is lost.

Instructions:

1. If the alarm is seen at the BSC, the transmission unit is not

working properly. However, if the base station otherwise operates

properly, there is no need for immediate repair. The transmission

alarms are not reported to the BSC.

2. If the alarm is seen on Nokia BTS Manager only, the transmission

unit is not operating. Reset the BCF.

3. If the alarm reappears after BCF reset, switch the cabinet power

off and on.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 699 (1095)

7609 TRE FAULTY

Page 700: Alarm

4. If the alarm reappears after the recovery actions above, replace

the faulty transmission plug-in unit.

ULTRASITE:

Fault reason : BOI detected that connection to transmission unit is lost.

Instructions:

1. If the base station otherwise operates properly, there is no need

for an immediate repair. However, the transmission alarms for

the node are not reported to the BSC nor the Nokia BTS Manager.

2. Reset BCF.

3. If the alarm reappears after the BCF reset, switch the cabinet

power off and on.

4. If the alarm reappears after the recovery actions above, replace

the faulty transmission plug-in unit located in slot 1.

Note: Replacing the unit blocks the base station

and cuts off the traffic routed through it.

Cancelling

This is a start/cancel type alarm. Alarm is cancelled automatically

or manually.

700 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 701: Alarm

3167612 SITE POWERING FAULTY

Meaning

(i) The site power system has a critical hardware failure. If the

failure is not corrected, it may cause additional damage to the

site power system and/or it causes the power supply to the

hardware reliant on it to be disrupted or fail.

(ii) Critical site power system parameter(s) are out of limits. If they

are not corrected, this causes damage to the site power system

and/or causes the power supply to the hardware reliant on it

to be disrupted or fail.

(iii) The mains supply to the site power system has failed and the

back-up batteries are now almost discharged. If mains power is not

restored quickly it causes the power supply to the hardware reliant

on the site power system to be disrupted or fail.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure.

Instructions

Fault reason : CCUA PSM alarm 1.

Instructions:

1. Use the PSM Manager software to check active SISU alarms and

follow the instructions given in the SISU operating manual.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 701 (1095)

7612 SITE POWERING FAULTY

Page 702: Alarm

Flexi EDGE:

Fault reason: Battery backup Alarm 1.

Description: Critical alarm is activated in external site support

equipment.

Instructions:

1. Connect to the external site support equipment to find the alarming

unit and resolve the fault.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

702 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 703: Alarm

3177613 SITE POWERING OPERATIONDEGRADED

Meaning

(i) The site power system has a major hardware failure which degrades

the performance of the site power system.

(ii) Major site power system parameters are out of limits which degrades

the performance of the site power system.

(iii) The mains supply to the site power system has failed. Note that

this condition may be alternatively indicated by the "Mains

Breakdown With Battery Backup" alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more ingormation, see Alarm Structure.

Instructions

Fault reason : CCUA PSM alarm 2.

Instructions:

1. Use the PSM Manager software to check active SISU alarms and follow

the instructions given in the SISU operating manual.

Flexi EDGE:

Fault reason: Battery backup Alarm 2.

Description: Major alarm is activated in external site support equipment.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 703 (1095)

7613 SITE POWERING OPERATION DEGRADED

Page 704: Alarm

Instructions:

1. Connect to the external site support equipment to find the alarming

unit and resolve the fault.

Fault reason: PSF Battery backup maintenance alarm.

Description: Alarm of severity major is activated in FPxx Power module.

Instructions:

1. Ensure that the ambient temperature of the base station is below

+50C/+122F.

2. Check that nothing obstructs the fan(s) from rotating.

3. Clean the fan unit of dust and/or dirt.

4. Check that power consumption of the BTS is lower than nominal

output power provided by FPMA.

5. Replace the alarming submodule.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

704 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 705: Alarm

3187614 SITE POWERING NOTIFICATION

Meaning

(i) The site power system has a minor hardware failure which may degrade

the performance of the site power system under some conditions.

(ii) Minor site power system parameters are out of limits which may

degrade the performance of the site power system under some

conditions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure.

Instructions

Fault reason : CCUA PSM alarm 3.

Instructions:

1. Use the PSM Manager software to check active SISU alarms and follow

the instructions given in the SISU operating manual.

Flexi EDGE:

Fault reason: Battery backup Alarm 3.

Description: Minor alarm is activated in external site support equipment.

Instructions:

1. Connect to the external site support equipment to find the alarming

unit and resolve the fault.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 705 (1095)

7614 SITE POWERING NOTIFICATION

Page 706: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

706 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 707: Alarm

3197615 RTS IS IN TEST USE

Meaning

Internal O&M software is testing time slots during the TRX loop test.

The TRX and the time slot tested are reported to the BSC. The

time slot cannot be used for call functions during the test.

Flexi EDGE:

Radio TS is in test use. Radio Time Slot(s) of EXxx TRX module are

undergoing a TRX (loop) test started from (remote) BTS Manager.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

Cancelling

This is a start/cancel type alarm. The alarm is cancelled automatically

once the test is completed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 707 (1095)

7615 RTS IS IN TEST USE

Page 708: Alarm

708 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 709: Alarm

3207616 OSCILLATOR ADJUSTINGTEMPORARILY INTERRUPTED

Meaning

The Abis frequency is too high or too low, or it fluctuates so much

that the master clock tune is unreliable and tends to oscillate too

much. Another reason for this alarm can be that the oven adjustment

scenario has tuned the oven too near the edge. When the tune is

stopped, the master clock can go by itself out of specification and

therefore calls may drop after several hours or days.

This is a non-fatal alarm but it indicates decreased traffic capacity

in the base station.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason : Oven oscillator adjustment function interrupted.

Instructions:

1. Check the Abis connection.

2. If the Abis connection is OK, replace the faulty VIFA unit.

ULTRASITE:

Fault reason : Oven oscillator adjustment function interrupted.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 709 (1095)

7616 OSCILLATOR ADJUSTING TEMPORARILY INTERRUPTED

Page 710: Alarm

Instructions:

1. Check that the Abis synchronisation is correct.

NOTE: The alarm is an indication that the BTS DAC

control value is less than 204 steps away from either

control range end limit (0 or 4095).

The adjusting of the BTS clock still continues. The alarm

is automatically cancelled when the control value is more

than 204 steps away from the control range end limits.

Flexi EDGE:

Fault reason: Clock tuning DAC word reaching min/max limit.

Description: Oven oscillator DAC word is within 5% of the min/max

limit. Alarm is activated if the DAC word is between 0-204 or

3891-4095. This alarm can be activated due to incorrect synchronisation

settings in transmission network.

Instructions:

1. Check the Abis synchronisation that there are valid Rx clock

sources available.

a. If the reference clock is ok, tune the ESMA clock to the

correct frequency.

b. If the reference clock is not ok, check the alarm history for

8xxx alarms for the possible reason for the incorrect reference

clock. Follow the instructions on 8xxx alarms. After correcting

the reference clock tune ESMA clock to the correct frequency.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

710 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 711: Alarm

3217617 SEVERAL CALLS DROPPED DUETO PROBLEM WITH TRANSCODER

Meaning

There is an error with the connection between the base station and

the transcoder.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure

Instructions

METROSITE:

Fault reason : There is an error with the connection between the BTS

and the transcoder.

Instructions:

1. Check the transmission path between the base station

and the transcoder.

ULTRASITE:

Fault reason : There is an error with the connection between the BTS

and the transcoder.

Instructions:

1. Check the transmission path between the base station

and the transcoder.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 711 (1095)

7617 SEVERAL CALLS DROPPED DUE TO PROBLEM WITHTRANSCODER

Page 712: Alarm

Cancelling

This is a start/cancel type alarm. Alarm is cancelled automatically

or manually.

712 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 713: Alarm

3227620 INCOMING POWER LOST

Meaning

The base station power supply unit has lost its main power.

NOTE: When this alarm is active, it will not be sent to Nokia BTS

Manager. However, alarm cancelling can be seen on Nokia BTS Manager.

NOTE: If the power loss is very short and power is on again within

1500 ms, the alarm is cancelled automatically and no actions are

required.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

1. Check the main supply.

2. If the main supply is OK, replace the power supply unit.

Cancelling

This is a start/cancel type alarm. The alarm is cancelled automatically.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 713 (1095)

7620 INCOMING POWER LOST

Page 714: Alarm

714 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 715: Alarm

3237621 INTOLERABLE CONDITIONS ONSITE

Meaning

The environmental conditions of the base station are intolerable.

Check the fault reason from the supplementary text field of the alarm.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Fault reason: Temperature inside the TRX is dangerously high

Instructions:

1. Check that the fan unit is operating.

2. If the fan unit is OK, ensure that the environment of the

base station site meets the conditions specified for

Nokia MetroSite BTS.

Note: An alarm is activated when the TRX unit

internal temperature exceeds +85C.

Flexi EDGE:

Fault reason: Base Station ambient temperature outside operating

range.

Description: Ambient temperature of the Base Station is either

below -35C/-31F or over +50C/+122F.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 715 (1095)

7621 INTOLERABLE CONDITIONS ON SITE

Page 716: Alarm

Instructions:

1. Ensure that the ambient temperature at the site is within

the limits (between -35...+50C/-31...+122F).

2. If the fault persists, replace ESMA.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

716 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 717: Alarm

3247622 CABINET OPEN

Meaning

The cabinet door is open or the cabinet cover has been removed.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

METROSITE:

Fault reason: Cabinet cover is open.

Instructions:

1. If the cover is attached, ensure it is secured properly.

If there is no cover, attach it during normal service operations.

ULTRASITE:

Fault reason: Cabinet door is open.

Instructions:

1. Ensure the cabinet door is properly closed and secured.

2. Check that the door switch is fitted properly in the cabinet

and that all related cabling is OK.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 717 (1095)

7622 CABINET OPEN

Page 718: Alarm

Cancelling

This is a start/cancel type alarm. Alarm is cancelled automatically.

718 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 719: Alarm

3257700 BTS OMU INITIALIZATION

Meaning

The OMU of the BTS has been started up.

Supplementary information fields

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 719 (1095)

7700 BTS OMU INITIALIZATION

Page 720: Alarm

720 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 721: Alarm

3267701 BCF INITIALIZATION

Meaning

The BCF has been started up.

Supplementary information fields

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 721 (1095)

7701 BCF INITIALIZATION

Page 722: Alarm

722 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 723: Alarm

3277702 BCF INITIALIZATION DUE TO BSSRESET

Meaning

The alarm is a BCF-specific notification of the start-up

of the BSS.

Supplementary information fields

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 723 (1095)

7702 BCF INITIALIZATION DUE TO BSS RESET

Page 724: Alarm

724 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 725: Alarm

3287704 PCM FAILURE

Meaning

The alarm concerns a PCM containing BCF links.

The radio network objects whose LAPD links are part of this

particular PCM are not functioning. Significance of this alarm

depends on the number and nature of LAPD links connected to this PCM.

Supplementary information fields

Instructions

Alarm 7704 is BCF-specific (the bcf_id is provided).

It is used by the RNW recovery part of the BSS system.

This alarm (and cancel) will cause radio network recovery

actions concerning objects connected through the faulty

PCM (ET). Alarm 7704 does not occur alone. There are always

some other alarms active at the same time.

FOR EXAMPLE:

PCM cable is disconnected from the ET. Alarms 7767, 2900, 2915,

7706 and 7704 are generated.

Alarm 7704 causes state change of corresponding TRX(s) to

BL-RSL and state change of corresponding LAPD links to

UA-AD RN RECOV.

In order to find out the cause or effects of this alarm,

check the following:

1. Check corresponding (ET<->PCM) active alarms (for

example 2915,2900)?

a) MML command AHO

b) See instructions for those alarms

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 725 (1095)

7704 PCM FAILURE

Page 726: Alarm

2. For further information observe the effects (RNW) of alarm 7704

with the MML commands

a) EEI

- which RNW objects are not usable?

b) EOL

- which alarms are directed at the specific BCF?

c) DTI

- what are the working states of OMUSIG and TRXSIG?

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

Exception: If this alarm is active when the corresponding

ET is changed to state SE-NH, cancel the alarm manually.

726 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 727: Alarm

3297705 LAPD FAILURE

Meaning

The alarm concerns the LAPD link of the TRX.

Supplementary information fields

Instructions

Check the LAPD link of the TRX.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 727 (1095)

7705 LAPD FAILURE

Page 728: Alarm

728 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 729: Alarm

3307706 BTS O&M LINK FAILURE

Meaning

The O&M link of the base station is not in operating state.

This prevents the O&M functions of the base station.

Supplementary information fields

Instructions

Check the O&M link of the base station. If the interruption in

the functioning has been long, the base station must be restarted

due to possible missing BTS alarms.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 729 (1095)

7706 BTS O&M LINK FAILURE

Page 730: Alarm

730 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 731: Alarm

3317708 TRX RESTARTED

Meaning

The alarm indicates the start-up of the TRX.

Supplementary information fields

Instructions

The alarm requires no actions.

Cancelling

No cancelling.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 731 (1095)

7708 TRX RESTARTED

Page 732: Alarm

732 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 733: Alarm

3327709 UNDEFINED BTS ALARM NUMBER

Meaning

The BTS has sent an alarm that is not defined in the BSC. This alarm

does not affect the RNW recovery system actions for the accused

object i.e. the recovery for the accused object is executed as it

would if the alarm was defined.

Supplementary information fields

1 the BTS alarm system of BSC does not have definition for this alarm

number

2-15 if the undefined alarm has additional information, it is placed

here. The additional information is cut after 14 bytes

Instructions

Correct the base station part indicated by the alarm.

Contact the local Nokia Customer Service Center.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 733 (1095)

7709 UNDEFINED BTS ALARM NUMBER

Page 734: Alarm

734 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 735: Alarm

3337710 OBJECT ADMINISTRATIVE STATECHANGED

Meaning

The administrative state of an object has been changed.

The additional information field displays the old and new state.

Supplementary information fields

Instructions

The alarm requires no actions.

Cancelling

No cancelling.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 735 (1095)

7710 OBJECT ADMINISTRATIVE STATE CHANGED

Page 736: Alarm

736 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 737: Alarm

3347711 WORKING FULL RATE TCH RATIOBELOW THRESHOLD

Meaning

The radio network configuration and failure management has

detected that the ratio between the number of full rate traffic

channels in the cell in normal working state (UNLOCKED-WORKING) and

the number of unlocked full rate traffic channels in the cell is

below the defined threshold.

Only one alarm per cell is possible. Object of the alarm is the BTS

which has the BCCH timeslot.

Supplementary information fields

1 N = normal TRX

E = extended range TRX

Instructions

Check why full rate channels in the cell in normal working state

(UNLOCKED-WORKING) or unlocked full rate channels in the cell are

out of use.

If the reason is a faulty TRX, correct the fault.

This will increase the number of channels

in normal working state, and the alarm is removed automatically.

The BSC-specific threshold value of the alarm can be changed

with the MMI command EEQ.

The new threshold value takes effect when the ratio

of the channels changes, for example, when

the administrative state of the TRX is changed, or when

the TRX's operative state changes.

The following formula is used in calculating the ratio:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 737 (1095)

7711 WORKING FULL RATE TCH RATIO BELOW THRESHOLD

Page 738: Alarm

( number of WO and BL-SHD full rate and dual rate traffic

channels / number of all full rate and dual rate traffic

channels excluding those in BL-USR state ) * 100

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

738 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 739: Alarm

3357712 WORKING SDCCH CHANNELRATIO BELOW THRESHOLD

Meaning

The radio network configuration and failure management

has detected that the ratio between the number of SDCCH

channels in the cell in normal working state (UNLOCKED-WORKING)

and the number of traffic channels in the cell in normal working state

(UNLOCKED-WORKING) is below the defined threshold.

Only one alarm per cell is possible. Object of the alarm is the BTS

which has the BCCH timeslot.

Supplementary information fields

1 N = normal TRX

E = extended range TRX

Instructions

Check why SDCCH channels in the cell in normal working state

(UNLOCKED-WORKING) or traffic channels (full and half rate)

in the cell in normal working state

(UNLOCKED-WORKING) are out of use. If the reason is a

faulty TRX, correct the fault. This increases the number of

SDCCH channels in normal working state, and the alarm is

removed automatically.

The BSC-specific threshold value of the alarm can be changed

with the MMI command EEQ.

The new threshold value takes effect as soon as the ratio of

the channels changes, for example, when the administrative

state of the TRX is changed, or when the TRX's operative

state changes.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 739 (1095)

7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD

Page 740: Alarm

The following formula is used in calculating the ratio:

( number of WO and BL-SHD SDCCH channels / number

of WO and BL-SHD traffic channels ) * 100

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

740 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 741: Alarm

3367713 SOFTWARE BACKGROUNDDOWNLOAD TO BCF FAILS

Meaning

The background download of the BCF software build has failed.

The additional information field is divided into the following

text-format subfields which are filled in order to identify the alarm:

PACK_STAT

status to which the attachment whose background download failed

was made. The values can be NW,BU or FB

FAULT_PHASE

phase of the background download in which the download error

took place. The values can be QUEUING, DOWNLOADING or

SAVING TO FLASH

DX_ERROR

DX 200 error code indicating the cause of the error.

This field is filled if the error took place in the QUEUING or

DOWNLOADING phase

NACK_REASON

BTS NACK cause code, if the error took place in storing the

software build to the flash memory

Supplementary information fields

Instructions

To download the software build to the BCF as a background operation,

detach the attachment and then make the attachment again

when the cause of the interruption has been removed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 741 (1095)

7713 SOFTWARE BACKGROUND DOWNLOAD TO BCF FAILS

Page 742: Alarm

Cancelling

Cancel the alarm with the MML command EOR.

742 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 743: Alarm

3377714 BCF REMOTE MMI CONNECTIONIS IN USE

Meaning

The BCF remote MMI connection is in use.

The additional information field is divided into the following

text-format subfields which are filled in order to identify the alarm:

CONNECTION_TYPE

type of the created connection. The values are:

OWN BSC, OTHER DX200 NE and NetAct

SYSTEM_ID

system identification of the system that made the external

connection (DW)

Supplementary information fields

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the remote MMI connection of the BCF in question is released.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 743 (1095)

7714 BCF REMOTE MMI CONNECTION IS IN USE

Page 744: Alarm

744 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 745: Alarm

3387715 CONTINUOUS RESTARTS OF BCF/TRX

Meaning

The O&M unit of the BCF or TRX is caught in a circle of resets

(the BCF has received at least 3 resets within

30 minutes). If the alarm 7767 (BCCH missing) is also set,

the circle of resets concerns the whole BCF site.

Supplementary information fields

Instructions

Find out why the BCF or TRX is receiving the resets.

Correct the error that causes the resets.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when 15 minutes have passed after the last reset of the BCF.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 745 (1095)

7715 CONTINUOUS RESTARTS OF BCF/TRX

Page 746: Alarm

746 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 747: Alarm

3397716 ACTIVE BCF HW DATABASEDIFFERENCE

Meaning

The HW database in the base station differs

from the active HW database allocated to the BCF in question

in the management system of the BSC's HW databases.

Supplementary information fields

Instructions

Activate a new HW database for the BCF from the BSC, or upload

the current database from the BCF and activate it in the BSC.

Cancelling

Cancel the alarm with the MML command EOR after taking the steps

described in the INSTRUCTIONS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 747 (1095)

7716 ACTIVE BCF HW DATABASE DIFFERENCE

Page 748: Alarm

748 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 749: Alarm

3407717 WORKING HALF RATE TCH RATIOBELOW THRESHOLD

Meaning

The radio network configuration and failure management

has detected that the ratio between the number of half rate

traffic channels in the cell in normal working state

(UNLOCKED-WORKING) and the number of unlocked half rate

traffic channels in the cell is below the defined threshold.

Only one alarm per cell is possible. Object of the alarm is the

BTS which has the BCCH timeslot.

Supplementary information fields

1 N = normal TRX

E = extended range TRX

Instructions

Check why half rate traffic channels in the cell in normal working state

(UNLOCKED-WORKING) or unlocked half rate traffic channels in the cell

are out of use.

If the reason is a faulty TRX, correct the fault.

This increases the number of channels in normal working state,

and the alarm is removed automatically.

The BSC-specific threshold value of the alarm can be changed

with the MMI command EEQ.

The new threshold value takes effect as soon as the ratio of

the channels changes, for example, when the administrative

state of the TRX is changed, or the TRX's operative state

changes.

The following formula is used in calculating the ratio:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 749 (1095)

7717 WORKING HALF RATE TCH RATIO BELOW THRESHOLD

Page 750: Alarm

( number of WO and BL-SHD half rate and dual rate traffic

channels in the cell/ number of all half rate and dual rate traffic

channels in the cell excluding those in BL-USR state ) * 100

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

750 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 751: Alarm

3417718 TRX NOT HOPPING DUE TO FAULT

Meaning

Because of a TRX reset the alarms of the TRX object are removed

from the active alarms of the BSC, but the TRX has remained

blocked and is not baseband hopping.

The situation can also result from a BCSU restart.

Supplementary information fields

Instructions

Set the BTS in LOCKED state (MMI command EQS) and after that,

set the BTS in UNLOCKED state (MMI command EQS). This causes

the hopping to be configured again, and the system tries to

bring the TRX found faulty back to use.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 751 (1095)

7718 TRX NOT HOPPING DUE TO FAULT

Page 752: Alarm

752 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 753: Alarm

3427719 TRX INITIALISATION

Meaning

The TRX is being initialised.

Supplementary information fields

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the initialisation of the TRX is finished.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 753 (1095)

7719 TRX INITIALISATION

Page 754: Alarm

754 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 755: Alarm

3437720 SDCCH ACTIVATION FAILURE

Meaning

Activating the control channel has failed a number of times.

Supplementary information fields

1 subtime slot identifier of the radio time slot

Instructions

The disturbance may be temporary, in which case no actions

are needed.

If the disturbance recurs repeatedly in the same base station,

find out the reason for the disturbance.

Cancelling

No cancelling.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 755 (1095)

7720 SDCCH ACTIVATION FAILURE

Page 756: Alarm

756 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 757: Alarm

3447721 COMMUNICATION FAILURE WITHBCF

Meaning

Time supervision has expired or the BCF has sent a

negative acknowledgement to the BSC, thereby cancelling

the ongoing message transfer sequence.

Supplementary information fields

1 reason for the failure (DX error code)

general error message of the system. See General Error Messages of

System for error code explanations.

Instructions

Correct the possible transmission failure in the Abis interface,

or correct the fault indicated by another active alarm in the BCF.

Cancelling

No cancelling.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 757 (1095)

7721 COMMUNICATION FAILURE WITH BCF

Page 758: Alarm

758 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 759: Alarm

3457722 ERROR IN BSS RADIO NETWORKDATABASE UPDATE

Meaning

The recovery or configuration management system of the BSS radio network

has failed to update the BSS Radio Network Configuration Database

(BSDATA)according to the changes in background parameters or the fault

situation affecting the radio network.

Moreover, the correct radio network configuration or the operational

state has not been updated to the BSC's call control program

blocks. Calls may be blocked in the cell in question.

If changes in background parameters are involved, also incoming and

outgoing handovers may fail.

Supplementary information fields

1 type of error

01 error in updating the operational state of the radio network

02 error in updating configuration of the radio network

object (BCF/BTS/TRX)

03 error in updating the frequency hopping parameters

04 error in updating the background parameters

05 error in updating the GPRS related parameters of BTS sent by PCU

2 task in which the error occurred

01 failure in the TSL

02 cancelling of the TSL failure

03 failure in the TRX

04 cancelling of the TRX failure

05 cell-specific failure

06 cancelling of the cell-specific failure

07 BTS-site-specific failure

08 cancelling of the BTS-site-specific failure

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 759 (1095)

7722 ERROR IN BSS RADIO NETWORK DATABASE UPDATE

Page 760: Alarm

09 restart of the BCSU

0A restart of the BTS site

0B correction request for the TRX configuration from

the call control

0C BTS/TRX unlock given by means of an MML command

0E battery backup recovery of the BTS site

0F testing of the TSL

14 restart of the TRX

15 blocking due to background parameter update

16 deblocking due to background parameter update

17 updating background parameter changes

18 hot reset

19 restart of the MCMU

20 blocking due to RNW plan activation

21 deblocking due to RNW plan activation

22 updating GPRS related parameters in BTS sent by the PCU

23 blocking due to RNW plan activation

24 deblocking due to RNW plan activation

25 updating the GPRS related parameters in BTS sent by PCU

26 updating plan parameter changes

27 Dual TRX manual power down

3 general error message of the system. See General Error Messages of

System for error code explanations

Instructions

1. Use the MML command DBS to check if the operational state of the

BSDATA is normal. If it is not, check whether the database system has

set alarms and act according to their instructions to recover from the

fault.

2. Check the value of the supplementary information

field 2 (interrupted task).

Interrupted task values:

03H, 04H or 17H:

Check radio network parameters of the cell. Radio network recovery

function may have changed some TRX's parameters before failure but

some TRX may have old parameters. Delete the TRX and then re-create

it with the correct parameters. Then change the BTS first to LOCKED

state and then to UNLOCKED state to ensure parameters updating to

BTS site.

If interrupted task is not any of the values above , check the value

of the supplementary information field 1 (error type).

Error type values:

01H or 03H:

Change the TRX first to LOCKED state and then to UNLOCKED state.

The radio network database should now be updated correctly. (MML

command ERS). If the update still fails, delete and

760 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 761: Alarm

re-create the BTS.

02H:

Delete the related radio network object (TRX, BTS, BCF) and then

re-create it with the correct parameters. The radio network database

should now be updated correctly.

04H:

Make the necessary radio network parameter changes manually with MML

commands EQS, ERS, EQE, EQP, EAM, ERM, ERY.

05H:

GPRS is disabled and enabled back to segment by GENA parameter.

Cancelling

Cancel the alarm with an MML command EOR after correcting the fault

as described in the INSTRUCTIONS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 761 (1095)

7722 ERROR IN BSS RADIO NETWORK DATABASE UPDATE

Page 762: Alarm

762 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 763: Alarm

3467723 FAILURE IN SENDING SYSTEMINFORMATION TO BTS SITE

Meaning

A failure has occurred in sending the system information

to the BTS site after the recovery measures or configuration changes

of the BSS radio network. The TRX in question or the whole cell

may be unable to transmit traffic.

Supplementary information fields

1 task in which the error occurred

03 failure in the TRX

04 cancelling of the TRX failure

06 cancelling of a cell-specific failure

09 restart of the BCSU

0A restart of the BTS site

0B a correction request of the TRX configuration from the call

control

0C BTS/TRX Unlock command given by means of an MML command

0D configuration change done by means of an MML command

0E battery backup recovery of the BTS site

10 spontaneous restart of the TRX or a change in the state of

the Gb interface

12 sending of periodic system information

13 updating of access classes

14 restart of the TRX

15 blocking due to background parameter update

16 deblocking due to background parameter update

17 updating background parameter changes

18 system HOT restart

23 blocking due to RNW plan activation

24 deblocking due to RNW plan activation

26 updating plan parameter changes

27 Dual TRX manual power down

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 763 (1095)

7723 FAILURE IN SENDING SYSTEM INFORMATION TO BTSSITE

Page 764: Alarm

2 general error message of the system. You can check its meaning

with a command of the service terminal extension MRS or in the

General Error Messages of System

Instructions

If the value of the supplementary information field 1 (Interrupted task)

is 12 or 13, cancel the alarm (MML command EOR).

If the value is other than 12 or 13, set the TRX into LOCKED state

and then to UNLOCKED state with the MML command ERS.

If the alarm is still active, check other alarms and error codes.

If one of them indicates a LAPD link failure, BCSU reset, BTS failure

or a disturbance in the radio network database, act according to the

instructions of the alarm in question.

If the alarm is still active, set the TRX into LOCKED state and then to

UNLOCKED state with the MML command ERS.

If none of the previous measures were effective, set the BCF in question

first into LOCKED state and then into UNLOCKED state with the

MML command EFS.

NOTE! All calls in that BCF will then be released.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

764 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 765: Alarm

3477724 CONFLICT BETWEEN BSS RADIONETWORK DATABASE AND CALLCONTROL

Meaning

The fault recovery or configuration management system of the BSS

radio network has updated the BSS Radio Network Configuration Database

(BSDATA) according to the changes in background parameters or the

fault situation in the radio network.

However, the update of the operational state of the radio

network or the update of the reconfiguration of the radio

network to the BSC's call control program block failed.

Due to the failed update, there is a conflict in radio network data

between the radio network database and the call

control program. Because of this, calls may be blocked in

the cell in question.

If changes in background parameters are involved, also the incoming

and outgoing handovers may fail.

Supplementary information fields

1 type of the error

01 error in updating the operational state of the radio network

02 error in updating the TRX configuration

03 error in updating the frequency hopping parameters

04 error in updating the background parameters

2 task in which the error occurred

01 failure in the TSL

02 cancelling of the TSL failure

03 failure in the TRX

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 765 (1095)

7724 CONFLICT BETWEEN BSS RADIO NETWORK DATABASEAND CALL CONTROL

Page 766: Alarm

04 cancelling of the TRX failure

05 cell-specific failure

06 cancelling of a cell-specific failure

07 a BTS-site-specific failure

08 cancelling of a BTS-site-specific failure

09 restart of the BCSU

0A restart of the BTS site

0B correction request of the TRX configuration from

the call control

0C BTS/TRX Unlock command given by means of an MML command

0D object modified by MML

0E battery backup recovery of the BTS site

0F testing of the TSL

14 restart of the TRX

15 blocking due to background parameter update

16 deblocking due to background parameter update

17 updating background parameter changes

18 system HOT restart

23 blocking due to RNW plan activation

24 deblocking due to RNW plan activation

26 updating plan parameter changes

27 Dual TRX manual power down

3 family identity of the application process whose update failed

1B3 Radio Connection Supervisor Program Block

1B4 Radio Resource Management Program Block

1BF Abis-interface Program Block

1EB Cell Broadcast Service Handling Program Block

434 Process in the PCU plug-in unit

4 general error message of the system. You can check its meaning

with a command of the service terminal extension MRS or in

General Error Messages of System

Instructions

Check the value of the supplementary information field 1 (error type).

Error type values:

01H or 04H:

If the value of field 2 (interrupted task) 15H, 17H, 23H or 26H,

cancel the alarm and make the database changes to the cell manually.

Check the adjacencies of the cell and update the data if needed. (MML

commands EOR, EQA, EQE, EAM, EAO, ERM, ERY).

If the value of field 2 is not 15H, 17H, 23H or 26H, cancel the alarm.

Then change the object in question to LOCKED state and then back to

UNLOCKED. The call control software receives thus the updated data.

(MML commands EOR, ERS, EQS).

02H:

If the value of field 3 (conflicting family) is 1B3H, cancel the

766 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 767: Alarm

alarm. Then change the parameter LEV of the TRX in question to a

different value and then back to the original value. TRX parameters

are thus updated to call control. (MML commands EOR, ERM).

If the value of the field 3 (conflicting family) is 434H, change

GPRS from enabled to disabled and back to enabled. If this does

not help, lock and unlock the BTS. Check also the state of

the PCU plug-in unit.

If the value of field 3 is not 1B3H or 434H, delete the TRX

in question and then re-create it with the correct parameters.

The call control software thus receives the correct data.

(MML commands ERD, ERC).

03H:

Set the BTS in question to LOCKED state. Set the HOPP parameter

value of the BTS to N (No Hopping) and then back to the original

value. The hopping parameters are thus updated to call control.

Finally, set the BTS to UNLOCKED state. (MML commands EQS, EQE).

If none of the previous measures were effective, set the BCF in

question first into LOCKED state and then into UNLOCKED state with the

MML command EFS. NOTE! All calls in that BCF will then be released.

If the alarm has not been cancelled yet, cancel the alarm

with the MML command EOR.

Cancelling

Cancel the alarm with an MML command after correcting the fault as

presented in the INSTRUCTIONS. See Alarm Administration.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 767 (1095)

7724 CONFLICT BETWEEN BSS RADIO NETWORK DATABASEAND CALL CONTROL

Page 768: Alarm

768 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 769: Alarm

3487725 TRAFFIC CHANNEL ACTIVATIONFAILURE

Meaning

The system has blocked the radio time slot because the call

control has failed a number of times in the activation of

a radio channel.

Supplementary information fields

1 Type of the channel whose TCH activation failed.

The channel type can be "TCH", "SDCCH", "Packet Data TCH"

or "DTM TCH".

The number value "0" indicates "TCH", "1" indicates "SDCCH",

"2" indicates "PDTCH" (Packet Data Traffic TCH) and "6" indicates

"DTM TCH" (Circuit switched TCH of DTM connection).

Instructions

if the failure type is "PDTCH", the alarm is cancelled automatically

by the system, when no more failure indications are observed

if the channel type is "TCH", "SDCCH" or "DTM TCH", cancel the alarm

with the MML command EOR. Deblock the radio time slot by first aligning

the TRX in question with the command ERS and then removing the alignment

of the TRX

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 769 (1095)

7725 TRAFFIC CHANNEL ACTIVATION FAILURE

Page 770: Alarm

Cancelling

If the channel type is "TCH", "SDCCH" or "DTM TCH", cancel the alarm

with a command before taking the steps described in the INSTRUCTIONS,

if the alarm has not been cancelled before. See instructions on base

transceiver station alarms handling.

770 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 771: Alarm

3497726 CELL IN MINIMUMCONFIGURATION

Meaning

The cell has been set to the minimum configuration due to

a failure in clock setting or clock synchronisation. Only the

BCCH-TRX is functioning.

This means that the number of working traffic channels in the cell has

decreased because only one TRX is functioning and others are in

BL-CLK state.

This is the result of the fact that several TRXs cannot work in a

non-synchronised mode in the same cell and so just one TRX is left

to WO state.

Synchronised handovers may be unsuccessful if cell is in minimum

configuration because TRXs are commanded to internal clock mode.

BTS_ID in the alarm is the BTS which has the BCCH timeslot.

Supplementary information fields

Instructions

1. Check alarms on clock synchronisation that are active in the

cell.

2. Before correcting the fault, set the BCF into LOCKED state with

the MML command EFS.

3. Correct the fault according to the instructions of the alarms

on clock synchronisation that are currently active in the cell.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 771 (1095)

7726 CELL IN MINIMUM CONFIGURATION

Page 772: Alarm

4. After correcting the fault, set the BCF into UNLOCKED state with

the MML command EFS. This resets the clocks. NOTE! All calls in the

cell are released.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the BCF or BTS is set to LOCKED state.

772 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 773: Alarm

3507727 TRAFFIC CHANNEL NUMBERDECREASED

Meaning

Some traffic channels have been lost in the configuration because of a

TRX or TCH swap made by the radio network recovery. The loss is possible

in the following situations:

The faulty control channel (BCCH, SDCCH, ERACH) TRX does not support

half rate channels and the control channel functionality is swapped to

a TRX that has half rate or dual rate channels in its configuration.

In this case, the number of traffic channels may decrease.

The traffic channels transferred to the faulty control channel TRX have

to be classified as NOTUSED, because the subslots for the sign parameter

of the faulty control channel TRX indicate that the time slots in

question have no Abis allocation.

If the BCSU resources run out during the TRX recovery of the TRX or TCH

swap, the traffic channels are also changed to NOTUSED channels. The

system changes the channel type from CH7 downwards.

The number of channels is observed for each BTS separately.

Supplementary information fields

1 The number of TCHH channels that were lost in the cell

configuration

2 The number of TCHD channels that were lost in the cell

configuration

3 The number of TCHF channels that were lost in the cell

configuration

4 The number of EGTCH channels that were lost in the cell

configuration

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 773 (1095)

7727 TRAFFIC CHANNEL NUMBER DECREASED

Page 774: Alarm

5 The number of LRTCH channels that were lost in the cell

configuration

Instructions

Find out why the faulty TRX is out of use by checking other alarms

affecting the TRX in question, and act according to their

instructions.

When the TRX is in working order again, return the channel

configuration back to the original. For more information, see

instructions on radio network administration.

Cancelling

The system can cancel this alarm automatically when the original TCH

count is returned. An example of this kind of situation is when the

TRX fault is cancelled and the BCCH TRX is swapped back to original

BCCH TRX.

This alarm is cancelled when the BTS's configuration is changed.

The creation/deletion of some TRX or RTSL type modification cancels

this alarm. The activation of a new RNW configuration (including

TRX creation/deletion or RTSL type modification) via plan also cancels

this alarm.

This alarm can be cancelled with the MML command EOR after taking the

steps described in the Instructions. For more information, see Base

Transceiver Station Alarms Handling, Command Reference Manual.

774 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 775: Alarm

3517728 OBJECT OUT OF USE BECAUSEOF ERROR IN BTS INTERNALDIAGNOSTICS

Meaning

Fault recovery has received a diagnostic block request from the BTS.

If the objects that the request applies to were in the WO state, fault

recovery has blocked them.

The BTS has not stopped internal runtime diagnostics automatically.

You can check the operational state of the object with the MML command

EEI. The operational state of the object under runtime diagnostics

is BL-DGN. Alarm is set when the operational state of the object is

BL-DGN. When the object is TRX, the operational state can also be

BL-RSL.

Supplementary information fields

Instructions

Lock and unlock the object with the following MML command: EFS for the

BCF, EQS for the BTS, or ERS for the TRX.

If the object stays blocked, it is faulty and other alarms specify

the fault.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 775 (1095)

7728 OBJECT OUT OF USE BECAUSE OF ERROR IN BTSINTERNAL DIAGNOSTICS

Page 776: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

776 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 777: Alarm

3527729 RADIO NETWORK RECOVERYFAILED

Meaning

The BSC radio network fault recovery failed. The cause of the failure

is one of the following:

- reading the radio network configuration data failed

- the BCF-specific recovery buffer in the alarm system is full

- re-sending a fault has been attempted the maximum number of times

- the recovery system sent a DX error code in its acknowledgement

- recovery was interrupted because of a system restart.

The result may be a cell which does not transmit traffic because

radio network recovery has not received the fault, or a cell whose

capacity is out of use although it is not faulty, or a recovery

action which could not be terminated.

Supplementary information fields

1 PCM identifier

2 DCS identifier as a hexadecimal

3 number of the recovery action being processed

4 identifier of the alarm system's filtering buffer

5 general error message of the system. See General Error Messages of

System for error code explanations.

Instructions

1. Check the supplementary information field 4 (buffer id). If the

value is FF, go to step 5. If the value is not FF, perform steps 2-4.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 777 (1095)

7729 RADIO NETWORK RECOVERY FAILED

Page 778: Alarm

2. Use the MML command EOL to check active alarms. Use the MML command

EOH to check the state of the alarm object (BCF) in the alarm history.

Check the state in the latest alarm directed to the BCF in question,

excluding this alarm.

3. Use the MML command EEI to check object states in the radio network

database.

The object state is wrong in the database, if

- alarm object state is DISABLED but WO in the database or if

- the object has no active alarms but its state is BL in the database.

4. Use the MML command EFS to lock the object which is in the wrong state

in the database and then unlock it with the same command. This updates

the correct object state in the radio network database.

5. Examine the alarm printout to find out the alarm object. If the object

is a radio network database object, perform step 6. If the object is

partly unknown (bcf id known), perform steps 7-8.

6. Lock and then unlock the alarm object. Use the MML command EFS for a

BCF, EQS for a BTS and ERS for a TRX.

7. Use the MML command EEI to check if the object has been created. If it

has not, create it. See instructions on BSS Integration

8. If the TRX id is 255 and the BTS type is Nokia Talk-family or Nokia

PrimeSite, check the logical IDs according to instructions in

BTS documentation.

Cancelling

Cancel the alarm with the MML command EOR after correcting the fault

as presented in the INSTRUCTIONS.

778 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 779: Alarm

3537730 CONFIGURATION OF BCF FAILED

Meaning

Configuring the radio network object from the BSC failed. The object is

not transmitting traffic.

Supplementary information fields

1 general error message of the system. You can check its meaning

with a command of the service terminal extension MRS or in the

General Error Messages of System, Supplementary References

255 UNSUCCESSFUL_EC

other malfunction between the BSC and the BTS

10675 OML_FAILURE_EC

configuring the BCF failed because of the O&M link state

11152 NBR_OF_FUS_NOT_CONSISTENT_EC

number of frame units is not consistent with the BTS

database

11153 BTS_DATABASE_DOES_NOT_EXIST_EC

BTS database does not exist

11154 NBR_OF_CUS_NOT_CONSISTENT_EC

number of carrier units is not consistent with the BTS

database

11155 DB_CREATED_BY_OLD_MMI_VERS_EC

database was created with an old MMI version

11156 INVALID_OBJ_TYPE_IN_MSG_EC

message contains an invalid object type

11157 RESP_FROM_BTS_TIMEOUT_EC

BTS has not responded within time supervision

11160 CONF_COMPL_TIMEOUT_EC

configuration was not completed within time supervision

11165 GUP_ACK_TIMEOUT_EC

radio network configuration management system is temporarily

out of resources

11251 ILLEGAL_BTS_SITE_TYPE_EC

requested operation is not supported by the defined site type

11365 ILLEGAL_DB_FORMAT_EC

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 779 (1095)

7730 CONFIGURATION OF BCF FAILED

Page 780: Alarm

BTS does not support the database format

11371 INV_CELL_CONFIG_EC

cell configuration is not compatible with the current

hardware

11372 INV_HOPPING_MODE_EC

hopping mode is invalid due to the restrictions of the

hardware

11478 NBR_OF_TRX_EC

number of TRXs in the configuration message is not consistent

with the BTS

12240 FATAL_SYNCH_FAIL_EC

Synchronisation settings of BCF in BSC's database are invalid

due to the restrictions of the hardware of BTS

12892 STATE_CHANGED_NOT_RECEIVED_EC

BSC has not received the BTS_STATE_CHANGED message because

the TRX configuration failed

13443 REALTIME_UPD_OML_FAIL_EC

updating the current time failed because of an O&M link fault

14951 REALTIME_UPD_OML_BUSY_EC

updating the current time failed because of a busy O&M link

14969 TRX_NOT_EDGE_CAPABLE_EC

GPRS enabled TRX is not EDGE capable, when EGPRS or CS3&CS4 is

enabled in the BTS

15839 CLOCK_REQ_WAITING_TIME_OUT_EC

BSC has not received an ack message from the BTS to

the BTS_CLOCK_REQ message

15844 EGPRS_BTS_TRXS_NOT_IN_DAP_EC

GPRS enabled TRX is not attached to Dynamic Abis Pool,

when EGPRS is enabled in the BTS

15953 BCCH_GTRX_NOT_EDGE_CAPABLE_EC

GPRS enabled BCCH TRX is not EDGE capable, when EGPRS or

CS3&CS4 is enabled in the BTS

15973 BCCH_EDGE_GTRX_NOT_IN_DAP_EC

GPRS enabled BCCH TRX is not attached to Dynamic Abis Pool,

when EGPRS is enabled in the BTS

15954 PBCCH_SYNC_LOST_EC

Abis synchronisation for PBCCH/PCCCH channel is failed

16368 CS3_CS4_BTS_GTRXS_NOT_IN_DAP_EC

GPRS enabled TRX is not attached to Dynamic Abis Pool,

when CS3&CS4 is enabled in the BTS

16369 BCCH_CS3_CS4_GTRX_NOT_IN_DAP_EC

GPRS enabled BCCH TRX is not attached to Dynamic Abis Pool,

when CS3&CS4 is enabled in the BTS

17088 TRXS_IN_GPRS_BTS_NOT_EDGE_EC

TRX does not have EDGE capable HW. When Extended Cell GPRS

parameter is enabled in the cell (EXGENA=Y), then all TRXs

in the BTS, which has GPRS Enabled TRX (GTRX=Y), must have

EDGE capable HW

Instructions

Correct the fault indicated in the supplementary information field.

If the error code in the supplementary information field is

11165 or 255, lock and then unlock the BCF with the MML command EFS.

780 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 781: Alarm

If the error code is 10675 and background parameters are being activated,

you must make the necessary radio network parameter modifications

manually for the BCF in question after the activation. After that,

lock and unlock the BCF with the MML command EFS.

If the error code is 11251, make sure that the site type definition in

the BSC corresponds to the actual BTS site type. After that, lock and

unlock the BCF with the MML command EFS.

If the error code is 13443 or 14951, the current time and date in the BSC

can be updated for the BTS by locking and unlocking the BCF.

If the error code is 12240 or 15839, make sure that BSC's and

synchronisation settings and hardware of the BTS are compatible.

After that, lock and unlock the BCF with the MML command EFS.

If the error code is 14969, lock the TRX, make the GPRS enabled TRX EDGE

capable in the BTS. *

After that unlock the TRX with the MML command ERS.

If the error code is 15844 or 16368, lock the GPRS enabled EDGE TRX(s)

and attach it to Dynamic Abis Pool (DAP) in the BTS. *

After that unlock the TRX with the MML command ERS.

If the error code is 15953, make GPRS enabled BCCH TRX EDGE capable. *

After that lock and unlock the TRX with the MML command ERS.

If the error code is 15973 or 16369, make sure that GPRS enabled BCCH TRX

is attached to Dynamic Abis Pool (DAP). *

After that lock and unlock the TRX with the MML command ERS.

* = If the error code is 14969, 15844, 16368, 15953, 15973 or 16369

and all TRXs do not have EDGE HW and they have been added to DAP

in the BTS, then the following conditions must also be taken into

account to make sure that the TRX recovery works correctly in

the EGPRS or CS3&CS4 enabled BTS:

- If a BCCH TRX is EDGE-capable, it has been added to EDAP, and it

has the GTRX parameter set to Y, all EDGE-capable unlocked TRXs

that have GTRX set to Y should be added to DAP and marked with

the preferred BCCH mark (PREF=Y).

- If a BCCH TRX is non-EDGE-capable and has the parameter GTRX set to

N, all the non-EDGE-capable unlocked TRXs that have GTRX set to

N should be marked with the preferred BCCH mark (PREF=Y).

1. Check whether the TRXs in the BTS have been configured correctly,

that is, whether the recommendation above has been followed.

2. a) If the configuration of the TRXs is not in order in the BTS,

1#. lock the BTS (EQS),

2#. lock the required TRX(s) (ERS),

3#. re-configure the TRX(s) (EQM),

4#. unlock the TRX(s) (ERS),

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 781 (1095)

7730 CONFIGURATION OF BCF FAILED

Page 782: Alarm

5#. unlock the BTS (EQS).

2. b) If TRX configuration is in order in the BTS,

lock & unlock the BTS (MML command EQS).

If the error code is 17088, make sure that the TRX's HW is EDGE capable.

Lock the TRX and make the TRX HW EDGE capable or take the extended

(E)GPRS out of use from the BTS. The Extended (E)GPRS of the BTS can

be disabled out of use with the MML command EQV.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

782 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 783: Alarm

3547731 BCF SW PACKAGE MAY BEDIFFERENTAS DEFINED AS A DEFAULTIN BSC

Meaning

BCF default software build (package) has not been solved. Software

download request has been sent to BCF with MF name filled as

********.***. SW build in the BCF may be different than the one

defined as a default build in the BSC.

Supplementary information fields

1 general error message of the system. You can check its meaning

in the General Error Messages of System

Instructions

Check the default software build defined for the BCF:

ZEWO:<bcf_id>:;

Check the OMU state in the BSC:

ZUSI:OMU;

If the OMU is in the WO-EX state restart the BCF:

ZEFR;

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 783 (1095)

7731 BCF SW PACKAGE MAY BE DIFFERENT AS DEFINED AS ADEFAULT IN BSC

Page 784: Alarm

784 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 785: Alarm

3557732 TEMPORARY ORIGINATING STMTEST CALL FAILURE

Meaning

An originating test call has failed due to lack of resources

during scheduled testing.

Supplementary information fields

1 BCF number of the main test object. The number indicates

the BCF where the STM used in the test is located

2 BTS number of the main test object

3 BCCH channel frequency number. Channel number indicates

the BCCH frequency of the test object

4 reason for failure (DX error code). If the value is

11477 (SIGNALLING BETWEEN THE STM AND THE NETWORK FAILED),

fields 5-8 may have additional information on the failure.

The fields are filled if the data is available at the base

station

5 reason for rejection in the failed call. If the value is 255,

it is not valid

6 reason for release in the failed call. If the value is 255,

it is not valid

7 cause of the alarm in the failed call. If the value is 255,

it is not valid

8 signalling stage in the failed call. If the value is 255,

it is not valid

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 785 (1095)

7732 TEMPORARY ORIGINATING STM TEST CALL FAILURE

Page 786: Alarm

Instructions

See field 4 for the DX error code. If the value is 11477 (2CD5h),

check the values in field 5-8 for more information.

See instructions on Radio Network Testing.

If the DX error code in field 4 is other than the above-mentioned,

see General Error Messages of System.

Cancelling

No cancelling.

786 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 787: Alarm

3567733 COMMUNICATION FAILURE WITHTRX

Meaning

Time supervision has expired or the TRX has sent a negative

acknowledgement to the BSC which has interrupted the ongoing message

exchange scenario.

The TRX O&M link may not be working and therefore, the ongoing

recovery action has been interrupted. The TRX functionality is not

reliable.

Supplementary information fields

1 general error message of system. See General Error Messages of

System for error code explanations.

Instructions

Correct the possible transmission fault in the Abis interface or

check with the MML command EOL if other active alarms concern the

TRX in question. If there is another active alarm, act according to its

instructions.

Check the TRX O&M link state with the MML command DTI. When the O&M link

is working, lock and unlock the TRX with the MML command ERS.

Cancelling

Cancel the alarm with the MML command EOR after correcting the fault

as presented in the INSTRUCTIONS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 787 (1095)

7733 COMMUNICATION FAILURE WITH TRX

Page 788: Alarm

788 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 789: Alarm

3577734 BCCH IS NOT AT PREFERREDBCCH TRX

Meaning

The BTS has at least one TRX defined as the preferred BCCH TRX but

the BCCH channel is not on such a TRX so the BCCH coverage may

have decreased.

This alarm is not set if the BCCH MISSING alarm is active.

Supplementary information fields

Instructions

This alarm usually results from a fault affecting the BTS's preferred

BCCH TRX. Check the radio network configuration with the MML command

EEI or the transceiver parameters with the MML command ERO.

Check active alarms with the MML command EOL and find out the

reason for the preferred BCCH TRX fault based on other alarms affecting

the BTS in question. Act according to the instructions of the other

active alarms. Check that the system moves the BCCH to the preferred

BCCH TRX and cancels this alarm.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected and the BCCH has been moved back

to the preferred BCCH TRX.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 789 (1095)

7734 BCCH IS NOT AT PREFERRED BCCH TRX

Page 790: Alarm

790 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 791: Alarm

3587735 TRX TEST FAILED

Meaning

The TRX test has failed. The test outcome is concluded by comparing the

test results to the threshold values. The traffic capacity is likely to

be decreased.

Supplementary information fields

1 number of the radio time slot used for the test

0...7

2 transmitted power

range 0...50 dBm

3 standing wave ratio

range 10...100. The actual SWR is 0.1 * the given value.

Value 255 (hex 0xFF) indicates that SWR is not measured

4 bit error rate value of the diversity branch 1

The value is BCD coded and the decimal point is after the fourth

byte: XXXX.XXXX

00000 ... 1000000

5 measured RX sensitivity value of the diversity branch 1

Indicates the absolute value of the signal level.

range (-)85...(-)118 dBm

0 (the receiver sensitivity is less than can be measured)

254 (could not be measured)

255 (sensitivity is better than minumum TXLEV)

6 bit error rate value of the diversity branch 2

The value is BCD coded and the decimal point is after the fourth

byte: XXXX.XXXX

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 791 (1095)

7735 TRX TEST FAILED

Page 792: Alarm

00000 ... 1000000

7 measured RX sensitivity value of the diversity branch 2

Indicates the absolute value of the signal level.

range (-)85...(-)118 dBm

0 (the receiver sensitivity is less than can be measured)

254 (could not be measured)

255 (sensitivity is better than minimum TXLEV)

Instructions

1. Use the MML command UCV to check that the threshold values of

result parameters are reasonable

ZUCV:TRP,CURRENT;

Change THE threshold values if they are not reasonable.

2. If the previous action fails to remove the fault, contact your

local Nokia Customer Service Center.

Cancelling

Do not cancel the alarm. The system cancels the alarm when the TRX

test (either single or scheduled) for the Nokia Metrosite or

Nokia UltraSite base station is successful in the TRX and

the diversity that generated the alarm.

The test succeeds when the threshold values set for the result

parameters are not exceeded.

792 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 793: Alarm

3597736 ABIS LOOP TEST FAILED

Meaning

The Abis Loop test has failed. The quality of the transmission path has

been decreased substantially. The Abis transmission is probably faulty.

The alarm is set if even one of the tested subtimeslots exceeds the

threshold value.

Supplementary information fields

1 state of the Abis transmission concerning to radio timeslot 0

00 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

2 state of the Abis transmission concerning to radio timeslot 1

01 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

3 state of the Abis transmission concerning to radio timeslot 2

02 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

4 state of the Abis transmission concerning to radio timeslot 3

03 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

5 state of the Abis transmission concerning to radio timeslot 4

04 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

6 state of the Abis transmission concerning to radio timeslot 5

05 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

7 state of the Abis transmission concerning to radio timeslot 6

06 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 793 (1095)

7736 ABIS LOOP TEST FAILED

Page 794: Alarm

8 state of the Abis transmission concerning to radio timeslot 7

07 means that RTSL was tested and the result of testing is 'FAILED'

FF means that the field is not significant

Instructions

1. Check the physical Abis transmission path and the cross-connection

equipment.

2. If required, reconfigure the TRX. See instructions on Radio Network

Administration, Primary Rate Access D-Channel Data Handling

and Primary Rate Access D-Channel State Handling.

2. The Abis Loop Test is not possible if baseband hopping is used.

Use the MML command EQO to see whether baseband hopping is used

and, if necessary, turn it off with the MML command EQE.

3. Execute the Abis Loop test to the whole TRX with the MML command UBK.

Cancelling

Do not cancel the alarm. The system cancels the alarm when the Abis

loop test has been executed successfully to the TRX or the RTSL that

has generated the alarm.

If the alarm is set for the TRX, the RTSL specific cancel cannot cancel

the TRX specific alarm. The TRX specific alarm can be cancelled only

when testing is requested to whole the TRX (every RTSLs are tested in

the same test request).

The test succeeds when the threshold values for the test result

parameters (BER/FER) are not exceeded. The user cannot change the

threshold parameters.

794 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 795: Alarm

3607737 INCONSISTENT DATA IN RADIORESOURCE MANAGEMENT STATEFILES

Meaning

BSC's radio resource management state files are faulty and as a result,

the BTS's traffic capacity may have decreased. The system

has attempted to return the state files back to normal by means of

an automatic procedure.

Supplementary information fields

1 estimate on BTS's traffic capacity after the restoration

0 test alarm, normal traffic capacity

1 traffic capacity has been returned to normal

2 traffic capacity has decreased

3 traffic capacity has substantially decreased

2 number of SDCCH channels working

3 number of full rate TCHs working

4 number of half rate TCHs working

5 number of blocked radio time slots

6 number of radio time slots removed from service

7 detector

C channel search algorithm

8 execution phase at which the fault was detected

9 total count of errors detected in state files

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 795 (1095)

7737 INCONSISTENT DATA IN RADIO RESOURCEMANAGEMENT STATE FILES

Page 796: Alarm

Instructions

Use the service terminal log extension LOGUTI command ZGSC

to output the log file of both the WO-MCMU and the SP-MCMU and save

the data.

You can monitor the BTS traffic capacity by using the BSC's

statistics measurements, radio network supervision function and

the E00HAN service terminal extension (Radio Resource Data Monitoring).

If the cell's traffic capacity has decreased due to a fault, delete

the BTS and create it again in the BSC.

Cancelling

Cancel the alarm with the EOR command after correcting the fault

as presented in the INSTRUCTIONS.

796 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 797: Alarm

3617738 BTS WITH NO TRANSACTIONS

Meaning

The BTS has had no successfully terminated calls or SDCCH transactions

during the supervision period.

The alarm is used for supervising the BTS traffic capacity.

Supplementary information fields

1 reason for the alarm

1 = no successful SDCCH seizures

2 = no successful TCH seizures

3 = no successful SDCCH nor TCH seizures

Instructions

Cancelling

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 797 (1095)

7738 BTS WITH NO TRANSACTIONS

Page 798: Alarm

798 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 799: Alarm

3627739 ORIGINATING STM TEST CALLFAILED

Meaning

An originating test call has failed during scheduled testing.

Supplementary information fields

1 BCF number of the main test object. The number indicates

the BCF where the STM used in the test is located

2 BTS number of the main test object

3 BCCH channel frequency number. Channel number indicates

the BCCH frequency of the test object

4 reason for failure (DX error code). If the value is

11477 (SIGNALLING BETWEEN THE STM AND THE NETWORK FAILED),

fields 5-8 may have additional information on the failure.

The fields are filled if the data is available at the base

station

5 reason for rejection in the failed call. If the value is 255,

it is not valid

6 reason for release in the failed call. If the value is 255,

it is not valid

7 cause of the alarm in the failed call. If the value is 255,

it is not valid

8 signalling stage in the failed call. If the value is 255,

it is not valid

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 799 (1095)

7739 ORIGINATING STM TEST CALL FAILED

Page 800: Alarm

Instructions

See field 4 for the DX error code. If the value is 11477 (2CD5h),

check the values in field 5-8 for more information.

See instructions on radio network testing.

If the DX error code in field 4 is other than the above-mentioned,

see General Error Messages of System.

Cancelling

Do not cancel the alarm. The system cancels the alarm when an

originating call through the base station succeeds.

800 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 801: Alarm

3637740 BEATING BTS ALARM

Meaning

The same radio network alarm has changed its alarm state (start/cancel/

disturbance/notice) 20 times consecutively, always during informing

or cancelling delay, and has thus been filtered by the alarm system.

The same radio network object is the object of both this alarm and

the beating alarm that caused this alarm.

Supplementary information fields

1 the alarm number of the beating BTS alarm

2-15 if the beating alarm has any additional information, it is

indicated here. Additional information is cut after 14

bytes and it is represented in hexadecimal format.

Instructions

Correct the fault that caused the original beating alarm. You can

find the number of that alarm in Supplementary information field 1.

Cancelling

Cancel the alarm with an MML command after correcting the fault as

presented in INSTRUCTIONS. See Alarm Administration.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 801 (1095)

7740 BEATING BTS ALARM

Page 802: Alarm

802 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 803: Alarm

3647741 MEAN HOLDING TIME ABOVEDEFINED THRESHOLD

Meaning

The mean holding time on the channel specified exceeds the

operator-defined threshold during the measurement period.

The alarm is used to supervise the functioning of the traffic and

signalling channels. It reveals unreleased calls.

Supplementary information fields

1 subchannel identification

00 - 01: TCH/H subchannel

F0 : TCH/F subchannel

C0 - C7: SDCCH subchannel

2 mean holding time on the channel in minutes

3 number of seizures on the channel during the measurement period

4 shortest seizure on the channel during the measurement period

in seconds

Instructions

Take E00 service terminal extension into use in the working MCMU

with the following command:

ZLE:<char>,E00_BXSX

Note that you need to check which MCMU is in the working state with the

command ZUSI:COMP;

Use the E00 service terminal extension command S to find out whether

the channel seizure that caused the alarm is a real call or an

unreleased channel.

Give the following command to the working MCMU unit:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 803 (1095)

7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD

Page 804: Alarm

Z<char>S:<BTS_id>,0,B,20;

Note that the parameter BTS_ID is given in hexadecimal format.

RRMPRB states are on CH STA column:

0=DISC 10=IDLE 20=BUSY FF=CBCH

ABIPRB states are on the last column of the output row:

0 = blocked

1 = free

2 = signalling

3 = conversation

4 = not in use

5 = CBCH

Compare the channel state in RRM and ABI to determine whether

the channel is unused but unreleased.

In the case of an unreleased channel, if it is a traffic channel,

restore the channel by first locking it out of use and then unlocking

it (TCH lock/unlock). Use the MML command ERS and give the TRX and

the channel as parameters.

ZERS:<BTS>,<TRX>,<CH>:L; lock

ZERS:<BTS>,<TRX>,<CH>:U; unlock

If it is a signalling channel, restore the channel by locking and then

unlocking the whole TRX (TRX lock/unlock). Use the MML command ERS

and give the TRX as a parameter.

Check that the parameters affecting the alarm are reasonable.

MML command EEO outputs the radio network supervision parameter values,

EEN command modifies the parameter values.

Parameters, with their default values, affecting the alarm:

ZEEN:MAXHTT= maximum mean holding time for TCH (120 min)

MAXHTS= maximum mean holding time for SDCCH (30 min)

PRDMHT= length of TCH supervision measurement (240 min)

PRDMHS= length of SDCCH supervision measurement (60 min)

Cancelling

If the alarm does not require user actions, you can cancel it with

the MML command EOR.

The system cancels the alarm when you lock and unlock the object in

question, or, if the alarm requires no user actions, the system cancels

the alarm at the end of the measurement period during which the channel

that caused the alarm is allocated/ released normally.

804 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 805: Alarm

3657742 BCF MAINTENANCE MODE

Meaning

The BCF has been set in maintenance mode. Alarm handling in the object

is limited.

Supplementary information fields

Instructions

Restart the BCF when you set the maintenance parameters back to their

original states or as soon as possible afterwards, as alarm handling

is limited during maintenance. The BCF restart is performed

automatically when the BCF is changed from maintenance mode to

normal mode, if the user has entered the parameter concerning restart.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the BCF maintenance mode parameters have been changed to:

RECOVERY = ON

PRINTING = ON

OMC_UPDATE = ON

BLOCKED = UNBLOCKED

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 805 (1095)

7742 BCF MAINTENANCE MODE

Page 806: Alarm

806 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 807: Alarm

3667743 MEAN HOLDING TIME BELOWDEFINED THRESHOLD

Meaning

Mean holding time on a channel is below the operator-defined minimum

during the measurement period. The alarm is used to supervise the

functioning of traffic channels and to detect the possible faulty

channels.

Supplementary information fields

1 indicates if the mean holding time is below the defined threshold

in time slot 0

00: above threshold (no alarm)

01: below threshold (alarm)

2 indicates if the mean holding time is below the defined threshold

in time slot 1

00: above threshold (no alarm)

01: below threshold (alarm)

3 indicates if the mean holding time is below the defined threshold

in time slot 2

00: above threshold (no alarm)

01: below threshold (alarm)

4 indicates if the mean holding time is below the defined threshold

in time slot 3

00: above threshold (no alarm)

01: below threshold (alarm)

5 indicates if the mean holding time is below the defined threshold

in time slot 4

00: above threshold (no alarm)

01: below threshold (alarm)

6 indicates if the mean holding time is below the defined threshold

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 807 (1095)

7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD

Page 808: Alarm

in time slot 5

00: above threshold (no alarm)

01: below threshold (alarm)

7 indicates if the mean holding time is below the defined threshold

in time slot 6

00: above threshold (no alarm)

01: below threshold (alarm)

8 indicates if the mean holding time is below the defined threshold

in time slot 7

00: above threshold (no alarm)

01: below threshold (alarm)

9 identifies the time slot where the mean holding time is shortest

10 identifies the subchannel in the time slot with the shortest mean

holding time

00: TCH/H subchannel 0

01: TCH/H subchannel 1

02: TCH/F subchannel

11 shortest mean holding time in seconds during the measurement period

(TCH)

Instructions

Find out the reason for the fault by examining the release causes in

channel release messages. Restore the channel by first locking it

out of use and then unlocking it with the MML command ERS.

ZERS:<BTS>,<TRX>,<CH>:L; lock

ZERS:<BTS>,<TRX>,<CH>:U; unlock

Check that the parameters affecting the alarm are reasonable.

The MML command EEO outputs the radio network supervision parameter

values and the EEN command modifies the parameter values.

Parameters, with their default values, affecting the alarm:

ZEEN:MINHTT = minimum mean holding time for a TCH (10 s)

PRDMHT = length of TCH supervision measurement (120 min)

CS = channel seizure threshold value (10)

Cancelling

If the alarm requires no user actions, you can cancel it with the

MML command EOR.

808 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 809: Alarm

The system cancels the alarm automatically in connection with the

user's locking and unlocking commands, or, if the situation is solved

without user actions, after the current measurement period.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 809 (1095)

7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD

Page 810: Alarm

810 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 811: Alarm

3677744 EXCESSIVE TCH INTERFERENCE

Meaning

During the supervision period, the TCH time slot has suffered

excessive interference in idle mode that is equal to or higher than

the operator-defined alarm threshold percentage. That is, the

interference in the time slot has lasted longer than is acceptable.

The interference level classified as excessive is defined by the

operator. The alarm is used to supervise the BTS traffic capacity.

Supplementary information fields

1-8 the percentage (per each TRX time slot) that the channel has

spent in excessive interference during the supervision period.

The number is a hexadecimal, 0 - 64 %.

If the time slot is not a TCH time slot, the value is 0

9 the threshold level of excessive interference. The values are

0, 1, 2, 3 and 4

10 the TCH channel's alarm threshold percentage of the time spent

in excessive interference, 1 - 100 %. The alarm is generated if

at least one TRX time slot reaches the threshold

Instructions

Measure the interference level on the traffic channel in question.

Check that the parameters affecting the alarm are reasonable.

MML command EEO outputs the radio network supervision parameter values,

EEN command modifies the parameter values.

Parameters, with their default values, affecting the alarm:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 811 (1095)

7744 EXCESSIVE TCH INTERFERENCE

Page 812: Alarm

ZEEN:HIFSHR= TCH interference level threshold value (50 %)

HIFLVL= excessive interference level threshold value (4)

PRDHIF= TCH interference supervision measurement (120 min)

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

812 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 813: Alarm

3687745 CHANNEL FAILURE RATE ABOVEDEFINED THRESHOLD

Meaning

The rate of calls terminating in failure on a channel is above the

threshold value set by the operator. The alarm is used to supervise

the functioning of traffic and signaling channels, and to detect

the possible faulty channels.

Supplementary information fields

1 indicates if the alarm is on the TCH or on the SDCCH channel

01: TCH

02: SDCCH

2 indicates if the channel failure rate is above the defined

threshold in time slot 0

00: belove threshold (no alarm)

01: above threshold (alarm)

3 indicates if the channel failure rate is above the defined

threshold in time slot 1

00: belove threshold (no alarm)

01: above threshold (alarm)

4 indicates if the channel failure rate is above the defined

threshold in time slot 2

00: belove threshold (no alarm)

01: above threshold (alarm)

5 indicates if the channel failure rate is above the defined

threshold in time slot 3

00: belove threshold (no alarm)

01: above threshold (alarm)

6 indicates if the channel failure rate is above the defined

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 813 (1095)

7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD

Page 814: Alarm

threshold in time slot 4

00: belove threshold (no alarm)

01: above threshold (alarm)

7 indicates if the channel failure rate is above the defined

threshold in time slot 5

00: belove threshold (no alarm)

01: above threshold (alarm)

8 indicates if the channel failure rate is above the defined

threshold in time slot 6

00: belove threshold (no alarm)

01: above threshold (alarm)

9 indicates if the channel failure rate is above the defined

threshold in time slot 7

00: belove threshold (no alarm)

01: above threshold (alarm)

10 time slot with the highest failure rate

11 subchannel identification TCH:

00: TCH/H -subchannel 0

01: TCH/H -subchannel 1

02: TCH/F -subchannel

subchannel identification SDCCH:

00 - 07: SDCCH -subchannel 0 - 7

12 proportion of TCH or SDCCH subchannel releases due to failure

in all channel releases on a given channel during the measurement

period

Instructions

Find out the reason for the alarm on the basis of the release causes

in channel release messages. Restore the channel by first locking it

out of use and then unlocking it with the MML command ERS.

ZERS:<BTS>,<TRX>,<CH>:L; lock

ZERS:<BTS>,<TRX>,<CH>:U; unlock

Check that the parameters affecting the alarm are reasonable.

MML command EEO outputs the radio network supervision parameter values,

EEN command modifies the parameter values.

Parameters, with their default values, affecting the alarm:

ZEEN:TCHFR = TCH failure rate (20 %)

SCHFR = SDCCH failure rate (80 %)

PRDCFR = length of supervision period (60 min)

CS = channel seizure threshold value (10)

814 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 815: Alarm

SMBNT = supervision start time (08-00)

EMBNT = supervision end time (18-00)

Cancelling

If the alarm requires no user actions, you can cancel it with the

MML command EOR.

The system cancels the alarm automatically in connection with the

user's locking and unlocking commands, or, if the situation is solved

without user actions, after the current measurement period.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 815 (1095)

7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD

Page 816: Alarm

816 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 817: Alarm

3697746 CH CONGESTION IN CELL ABOVEDEFINED THRESHOLD

Meaning

The percentage of rejected channel seizure requests due to congestion

as opposed to all channel seizure requests in the base station is

above the operator-defined alarm threshold. In the segment environment

this alarm describes the congestion situation of the whole cell although

it is only given to the BCCH BTS.

The alarm is used to supervise the traffic capacity of the base

station.

Supplementary information fields

1 object of congestion

01 SDCCH

02 TCH

03 extended cell SDCCH

04 extended cell TCH

2 the time (hours, minutes) when congestion was last observed during

the measurement period

3 number of channel seizure requests during the measurement period

4 percentage of rejected SDCCH or TCH (depending on the

congestion object) seizure requests due to congestion in all

channel seizure requests during the measurement period. The

TCH percentage includes all half rate, full rate and rate

recommendation channel seizure requests

5 percentage of rejected half rate channel seizure requests due

to congestion in all seizure requests during the measurement period;

only significant, if the congestion object is a TCH

6 percentage of rejected full rate channel seizure requests due

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 817 (1095)

7746 CH CONGESTION IN CELL ABOVE DEFINED THRESHOLD

Page 818: Alarm

to congestion in all seizure requests during the measurement period;

only significant, if the congestion object is a TCH

7 this new field is significant only if the congestion object is a TCH.

The new field is a percentage value and indicates how big a portion

of the refused TCH requests (field refused_calls_percentage) have

been refused due to lack of traffic handling capacity in the BCSUs.

Instructions

Increase the network capacity if necessary.

Check that the parameters affecting the alarm are reasonable.

MML command EEO outputs the radio network supervision parameter values,

EEN command modifies the parameter values.

Parameters, with their default values, affecting the alarm:

ZEEN: CSR: channel seizure request threshold value (10)

CNGS: SDCCH congestion threshold value (20 %)

CNGT: TCH congestion threshold value (20 %)

PRDCNG: length of congestion supervision period (120 min)

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

818 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 819: Alarm

3707747 RX SENSITIVITY MEASUREMENTTEST FAILED

Meaning

A scheduled RX sensitivity measurement test failed. A test fails when

one of the threshold values for errors in the result parameters is

exceeded.

Supplementary information fields

1 number of the radio time slot used for the test

0...7

2 calculated RX sensitivity value

(-)90 ... (-)110 dBm

0 = sensitivity is less than with the test

equipment can be measured

255 = sensitivity is better than with the test

equipment can be measured

3 measured RX sensitivity value

(-)85 ... (-)110 dBm

0 = sensitivity is less than with the test

equipment can be measured

255 = sensitivity is better than with the test

equipment can be measured

4 bit error rate value.

The value is BCD coded and the decimal point is after the fourth

byte: XXXX.XXXX

00000 ... 1000000

5 bit error rate value in second class bits.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 819 (1095)

7747 RX SENSITIVITY MEASUREMENT TEST FAILED

Page 820: Alarm

The value is BCD coded and the decimal point is after the fourth

byte: XXXX.XXXX

00000 ... 1000000

Instructions

1. Check that the threshold values of result parameters are reasonable.

2. Check whether frequency hopping is on in the BTS being

tested. If it is, cancel frequency hopping and run the RX

sensitivity measurement test for all TRXs in the BTS.

3. If frequency hopping is not on in the BTS being tested,

run the RX sensitivity measurement single test for the TRX

that generated the alarm.

Cancelling

Do not cancel the alarm. The system cancels the alarm when the RX

sensitivity measurement test (either single or scheduled) is

successful in the TRX that generated the alarm.

The test succeeds when the threshold values set for the result

parameters are not exceeded.

820 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 821: Alarm

3717748 BCF BACKGROUND DATA SWAPTIMER EXPIRED

Meaning

Background loading of the radio network plan failed in the BCF that

generated the alarm. This is because the BCF has continually been

reserved for configuration or recovery actions. Due to a failure in

background loading, the radio network data is now contradictory.

Supplementary information fields

Instructions

The changes that were supposed to be made in the background

loading of radio network data must be done manually.

Use the MML commands EQE, EQA, ERM, ERY and EAM to

make the changes to all the BTSs and their TRXs as well as to

the outgoing adjacencies of the BCF that generated the alarm.

Cancelling

Cancel the alarm with the MML command EOR after taking the steps

described in the Instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 821 (1095)

7748 BCF BACKGROUND DATA SWAP TIMER EXPIRED

Page 822: Alarm

822 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 823: Alarm

3727749 E-RACH MISSING

Meaning

The extended cell coverage of the cell has been lost. The ERACH ETRX is

faulty and the BTS cannot find a TRX that could be reconfigured.

The alarm is also set if the BCCH TRX is faulty and the ERACH ETRX

is reconfigured as the BCCH TRX. Only one alarm per cell is possible.

The object of the alarm is the BTS with the BCCH timeslot.

Supplementary information fields

Instructions

The alarm usually results from an error situation, detected by the

BTS or the BSC, that affects the BTS. Find out the reason for the

ERACH failure on the basis of other alarms affecting the BTS.

Correct the fault and check that the system cancels the alarms

affecting the faulty resource. Check also that the system restores

the ERACH to normal working state.

If needed, restart the faulty TRX, BTS or BCF ,for example with the BSC's

MML commands (lock/unlock). When the resource is restarted,

the system cancels the alarms of the resource. It sets the

alarms of the resource again if the fault situation continues.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 823 (1095)

7749 E-RACH MISSING

Page 824: Alarm

824 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 825: Alarm

3737751 TEST TIME SLOT RELEASE FAILED

Meaning

Releasing the channel reserved for testing failed.

The time slot in question is not available for traffic.

Supplementary information fields

1 general error message of system. See General Error Messages of System

for error code explanations.

Instructions

Release the channel by locking and unlocking the TRX with the

MML command ERS:

ZERS:<BTS>,<TRX>:L; lock

ZERS:<BTS>,<TRX>:U; unlock

Cancelling

Cancel the alarm with the MML command EOR after correcting the

fault as presented in the INSTRUCTIONS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 825 (1095)

7751 TEST TIME SLOT RELEASE FAILED

Page 826: Alarm

826 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 827: Alarm

3747752 TRX TEST FAILED

Meaning

A scheduled or a single TRX test failed. The test fails when an

error rate value of the result parameter is exceeded.

The TRX's traffic capacity has probably decreased.

Supplementary information fields

1 number of the diversity branch tested

1 = diversity branch 1

2 = diversity branch 2

2 identifier of radio time slot tested

0 .. 7

3 bit error ratio.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

4 bit error ratio for 2nd class bits.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

5 number of the invalid CU

1 ... 16

6 result of the first LNA (Low Noise Amplifier) PATH.

The result may be:

0 = not used

1 = good

2 = radio problem

3 = transmission error

7 result of the second LNA (Low Noise Amplifier) PATH.

The result may be:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 827 (1095)

7752 TRX TEST FAILED

Page 828: Alarm

0 = not used

1 = good

2 = radio problem

3 = transmission error

8 result of the test equipment.

The result may be:

0 = not used

1 = good

2 = radio problem

3 = transmission error

Instructions

1. Check that the threshold values of result parameters are reasonable.

See instructions on scheduled radio network test handling.

2. Check if the base station to be tested has frequency hopping on.

If it does, set it off. See instructions on base transceiver station

handling in BSC. After that, execute the TRX test to all

the TRXs in the BTS.

3. Execute a single TRX test to the alarming TRX.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the TRX test (single or scheduled) is successful in the

previously faulty TRX and diversity. The test is successful when the

result parameter threshold values are not exceeded.

828 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 829: Alarm

3757753 TRX LOOP TEST FAILED

Meaning

A scheduled or a single TRX loop test failed. The test fails when an

error rate value of the result parameter is exceeded.

The TRX's traffic capacity has probably decreased.

Supplementary information fields

1 number of the diversity branch tested

1 = diversity branch 1

2 = diversity branch 2

2 identifier of radio time slot tested

0 .. 7

3 bit error ratio.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

4 bit error ratio for 2nd class bits.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

5 frame error ratio.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

6 RX quality parameter. The value is BCD coded

0 .. 7.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 829 (1095)

7753 TRX LOOP TEST FAILED

Page 830: Alarm

Instructions

1. Check that the threshold values of result parameters are reasonable.

2. Check if the base station to be tested has frequency hopping on.

If it does, set it off. See instructions on Base Transceiver Station

Handling in BSC.

After that, execute the TRX test to all

the TRXs in the BTS.

3. Execute a single TRX test to the alarming TRX.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the TRX loop test (single or scheduled) is successful in the

previously faulty TRX and diversity. The test is successful when the

result parameter threshold values are not exceeded.

830 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 831: Alarm

3767754 ANTENNA LOOP TEST FAILED

Meaning

A scheduled or a single antenna loop test failed. The test fails when

an error rate value of the result parameter is exceeded.

The TRX's traffic capacity has probably decreased.

Supplementary information fields

1 number of the diversity branch tested

1 = diversity branch 1

2 = diversity branch 2

2 identifier of radio time slot tested

0 .. 7

3 bit error ratio.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

4 bit error ratio for 2nd class bits.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

5 frame error ratio.

The value is BCD coded and a decimal point is after the

fourth digit: XXXX.XXXX

00000000 .. 01000000

6 RX quality parameter. The value is BCD coded

0 .. 7.

7 standing-wave ratio.

The value is between 10 .. 100 in the alarm. The real SWR

is 0.1 * incoming value

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 831 (1095)

7754 ANTENNA LOOP TEST FAILED

Page 832: Alarm

Instructions

1. Check that the threshold values of result parameters are reasonable.

2. Check if the base station to be tested has frequency hopping on.

If it does, set it to off. See Base Transceiver Station Handling in

BSC. After that, execute the TRX test to all the TRXs in the BTS.

3. Execute a single antenna loop test to the alarming TRX.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the TRX loop test (single or scheduled) is successful in the

previously faulty TRX and diversity. The test is successful when the

result parameter threshold values are not exceeded.

832 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 833: Alarm

3777755 PHASE 1 BTS IS TRIED TO BEDEFINED AS DUAL BAND BTS

Meaning

Dual band definition in the database is faulty, because the phase 1

BTS does not support the Dual Band feature.

Supplementary information fields

Instructions

Remove the dual band definition in the cell in question with the

MML command EQF.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 833 (1095)

7755 PHASE 1 BTS IS TRIED TO BE DEFINED AS DUAL BANDBTS

Page 834: Alarm

834 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 835: Alarm

3787756 BLOCKED BECAUSE WAITINGFOR ABIS AUTOCONFIGURATION

Meaning

The operator has unlocked a site (BCF) or a transceiver (TRX) that is

waiting for Abis autoconfiguration.

The BCF or TRX in question cannot carry traffic before the BSC has

allocated the Abis circuits for signalling and traffic channels,

i.e. the autoconfiguration has been completed.

Supplementary information fields

Instructions

1. Check that the Abis autoconfiguration pool has been created.

If not, create the pool.

Abis autoconfiguration pool interrogation and creation:

- MML command ESO (interrogation)

- MML command ESC (creation)

2. Start autoconfiguration on the BTS site for the whole BCF or an

extension TRX.

Cancelling

The system cancels the alarm when the Abis autoconfiguration has been

completed or the operator locks the TRX/BCF.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 835 (1095)

7756 BLOCKED BECAUSE WAITING FOR ABISAUTOCONFIGURATION

Page 836: Alarm

836 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 837: Alarm

3797757 ABIS AUTOCONFIGURATIONFAILED

Meaning

The operator has started the Abis autoconfiguration but it has failed.

Supplementary information fields

1 information on why the autoconfiguration has failed

The pool is not found

The BSC's C-number is wrong

The BCF has not been created in the BSC

The BCF is not waiting for autoconfiguration

The TRX is not waiting for autoconfiguration

The TRX has already been autoconfigured

There are no TRXs to autoconfigure

Links cannot be combined

Allocation cannot be optimised

There is no room for circuits in the pool

The BCF cannot be reserved for autoconfiguration

Modifying the OMUSIG has failed

Activating the OMUSIG has failed

Modifying the TRXSIG has failed

Activating the TRXSIG has failed

The traffic channel allocation has failed

The message from the BTS is missing

The BTS has interrupted the scenario

Instructions

For more information, see the computer log of the MCMU (Marker and

Cellular Management Unit) and act according to the more specific error

data (i.e. link number, trx_id, bcf_id, incorrect BSC's C-number,

pool_id, incorrect access channel id).

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 837 (1095)

7757 ABIS AUTOCONFIGURATION FAILED

Page 838: Alarm

After you have found the reason for the error and corrected it, try

the Abis autoconfiguration again.

1. Check that the Abis autoconfiguration pool has been created.

If not, create the pool.

Abis autoconfiguration pool interrogation and creation:

- MML command ESO (interrogation)

- MML command ESC (creation)

2. Start the Abis autoconfiguration on the BTS site for the whole BCF

or an extension TRX.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the autoconfiguration has been completed.

838 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 839: Alarm

3807758 ABIS AUTOCONFIGURATIONCOMPLETED

Meaning

The operator has started the Abis autoconfiguration and the operation

has been completed successfully.

Supplementary information fields

1 status of the commission tests

0000 SUCCESS_EC

All tests passed

34AC ACM_BTS_TEST_FAILURE_EC

Some test(s) failed

34AB ACM_BTS_PARTLY_TESTED_EC

Not all tested

Instructions

1. Check Supplementary information field 1 to make sure that all the

tests have been executed successfully.

2. If the testing has failed, the TRX or Abis Loop test should be run

again.

TRX test and Abis Loop test:

- MML command UBS (TRX test)

- MML command UBK (Abis loop test)

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 839 (1095)

7758 ABIS AUTOCONFIGURATION COMPLETED

Page 840: Alarm

Cancelling

No cancelling.

840 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 841: Alarm

3817759 BTS SYNCHRONIZATION SETTINGFAILED

Meaning

The setting of BTS synchronization has failed. BTS synchronization

may be lost. In the synchronized BSS the LMU equipment is used as a

synchronization source for BTS.

This alarm may affect the provided services.

Supplementary information fields

1 type of Location Measurement Unit the fault is associated with

2 identification of Location Measurement Unit the fault is associated

with

Instructions

Restart BCF by locking and unlocking it with the MML command EFS to

cause new frame number offset setting to BCF.

When the BCF is restarted the system cancels all alarms affecting the

BCF, and, if necessary, sets them again.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 841 (1095)

7759 BTS SYNCHRONIZATION SETTING FAILED

Page 842: Alarm

842 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 843: Alarm

3827763 ACCESS CLASS BARRED

Meaning

This alarm indicates the operator the starting and ending moments of

access class control involving access class 12, 13, or 14.

Supplementary information fields

1 MS class not allowed to access the cell

Instructions

The alarm is set when the user has blocked access class 12, 13, or 14

for the BTS. The alarm is cancelled when the user reopens the access

class.

Note that if all three access classes 12, 13, and 14 are blocked for

the BTS, the alarm is set three times for same BTS.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the access class restriction has been removed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 843 (1095)

7763 ACCESS CLASS BARRED

Page 844: Alarm

844 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 845: Alarm

3837764 DFCA USE PREVENTED DUEANOTHER BSC UNCONTROLLEDINTERFERENCE

Meaning

The interference that a BTS is experiencing from a remote cell behind

a broken inter-BSC connection has become significant. This prevents

the use of the DFCA algorithm in the BTS.

Supplementary information fields

1 signaling Point Code that has become unreachable

2 number of remote neighbour cells that can cause excessive

interference

3 the lowest C/I value among the lost neighbour cells meaning the

worst possible interference

Instructions

The alarm requires no actions from the user.

The BSC takes automatic actions to reconfigure the BTS to unsynchronized

random frequency hopping operation.

Cancelling

Do not cancel the alarm.

The system cancels the alarm automatically when the fault has been

corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 845 (1095)

7764 DFCA USE PREVENTED DUE ANOTHER BSCUNCONTROLLED INTERFERENCE

Page 846: Alarm

846 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 847: Alarm

3847765 DFCA NEIGHBOUR CELLCONFLICT

Meaning

The BSC has noticed that a DFCA cell has a neighbour cell with the same

BCCH frequency or that a DFCA cell has two neighbour cells which have the

same BCCH and BSIC combination.

Supplementary information fields

1 1 = modified BCCH of the serving cell is conflicting with the BCCH

of an interfering cell

2 = modified BCCH of an interfering cell is conflicting with the

BCCH of the serving cell

3 = BCCH-BSIC conflict between two interfering cells at the

relation initiation

4 = BCCH-BSIC conflict between two interfering cells at the

cell information change

2 BCCH carrier frequency number that has been used too frequently

3 with alarm types 1 and 2, NCC_1 is the NCC of the serving cell,

with alarm types 3 and 4, NCC_1 is the conflicting NCC

4 with alarm types 1 and 2, BCC_1 is the BCC

of the serving cell,

with alarm types 3 and 4, BCC_1 is the conflicting BCC

5 with alarm types 1 and 2, NCC_2 is the NCC of the

neighbouring cell, with alarm types 3 and 4, NCC_2 has no meaning

6 with alarm types 1 and 2, BCC_2 is the BCC of the

neighbouring cell, with alarm types 2 and 3, BCC_2 has no meaning

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 847 (1095)

7765 DFCA NEIGHBOUR CELL CONFLICT

Page 848: Alarm

7 signalling Point Code for a BSC involved in the conflict

8 signalling Point Code for a BSC involved in the conflict

Instructions

Find the cells with the indicated BCCH_ARFCN, NCC, and

BCC values from the BSCs.

In alarms of type 1 or 2, change the BCCH_ARFCN for one of

the involved cells. Update also the relevant adjacent

cell parameters based on the BCCH_ARFCN change.

In alarms of type 3 or 4, change the BCCH_ARFCN, NCC, or BCC

for one of the involved cells. Update also the relevant adjacent

cell parameters based on the BCCH_ARFCN change.

Cancelling

Do not cancel the alarm.

The system cancels the alarm automatically when the fault has been

corrected.

848 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 849: Alarm

3857767 BCCH MISSING

Meaning

The base station system has become faulty and the BSC recovery has

not been able re-configure a working BCCH to the BTS.

The system also sets this alarm if the BTS in question is in the

normal working state but no BCCH-TRX has been configured to the BTS

or if the BCCH-TRX of the BTS is locked by the user.

The base station cannot transmit traffic without a working BCCH.

Supplementary information fields

Instructions

This alarm is usually a result of a fault situation in the BTS

detected by the BTS or the BSC. Use the MML command EOL to list other

alarms affecting the BTS and act according to their instructions.

Check that the system cancels the alarms (including this alarm)

affecting the faulty unit. This returns the BCCH-TRX to the WO state.

If the system does not cancel this alarm, lock and unlock the faulty

object (BCF/BTS/TRX) with the EFS/EQS/ERS MML command. This causes

the object to restart. The system then cancels all alarms affecting

the unit, and if necessary, sets them again. In such a case, correct

the fault according to the instructions in the active alarms

affecting the unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 849 (1095)

7767 BCCH MISSING

Page 850: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when a working BCCH-TRX has been configured for the BTS.

850 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 851: Alarm

3867768 INCONSISTENT DATA IN DFCARADIO RESOURCE STATE FILES

Meaning

BSC's radio resource management state files are faulty.These files

concern interfering and interfered neighbour cells that are examined

in the Dynamic Frequency and Channel Allocation feature are faulty.

As a result, the efficiency of the DFCA algorithm in the cell may have

decreased. The system has attempted to return the state files back to

normal by means of an automatic procedure.

Supplementary information fields

1 segment object that the BTS of the alarm belongs to

2 interfering or interfered neighbour segment whose radio resource

state data was found to be contradictory

1..248 segment in the serving BSC

249..1488 segment in a neighbouring BSC

3 detecting instance of the radio resource manager

C channel search algorithm

4 execution phase at which the fault was detected

5 number of neighbour segment channel records for which the

information on the used frequency has been corrected

6 number of neighbour segment channel records that have been cleared

due to an illegal pointer to the DFCA radio resource table

7 number of neighbour segment channel records that have been cleared

due to a pointer to an empty DFCA radio resource table record

8 number of neighbour segment channel records that have been cleared

due to a pointer to a wrong DFCA radio resource table record

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 851 (1095)

7768 INCONSISTENT DATA IN DFCA RADIO RESOURCE STATEFILES

Page 852: Alarm

9 total number of times the radio resource manager has come across

an error in the DFCA state files

Instructions

Use the service terminal log extension LOGUTI command ZGSC

to output the log file of both the WO-MCMU and the SP-MCMU and save

the data.

Make a problem report and attach the saved information to it.

You can monitor the BTS traffic capacity by using the BSC's performance

monitoring statistics, the radio network supervision function and

the E00HAN service terminal extension (Radio Resource Data Monitoring).

Cancelling

Cancel the alarm with the EOR command after performing the actions

presented in the OPERATING INSTRUCTIONS.

852 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 853: Alarm

3877769 FAILURE IN UPDATING CELLSPECIFIC PARAMETERS TO PCU

Meaning

A failure has occurred in updating the cell specific parameters to the

PCU.

Supplementary information fields

1 the task in which the error occurred

03 failure in the TRX

04 cancelling of the TRX failure

06 cancelling of a cell-specific failure

09 restart of the PCU/BCSU

0A restart of the BTS site

0B a correction request of the TRX configuration from the call

control

0C BTS/TRX Unlock command given by means of an MML command

0D configuration change which is delivered to the PCU

and done by an MML command

0E battery backup recovery of the BTS site

14 restart of the TRX

15 blocking due to background parameter update

16 deblocking due to background parameter update

17 update of PCU background parameter changes which

are delivered to the PCU

18 hot reset

19 restart of the MCMU

22 plan activation

23 blocking due to RNW plan activation

24 deblocking due to RNW plan activation

26 updating plan parameter changes

27 Dual TRX manual power down

2 family identity of the application process whose update failed

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 853 (1095)

7769 FAILURE IN UPDATING CELL SPECIFIC PARAMETERS TOPCU

Page 854: Alarm

434 PCU process in BSC in the PCU plug-in unit

663 Network Reselection Handling Actor in the PCU plug-in unit

3 a general error message of the system. You can check its meaning

with a command of the service terminal extension MRS or in

General Error Messages of System

Instructions

Change the value of the parameter GENA of the cell in question to N

and then back to the original value.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

854 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 855: Alarm

3887770 AUTOMATIC UNLOCK OF BCFFAILED

Meaning

Failure in BCF unlock by system.

Supplementary information fields

1 Reason for the failure (DX error code)

General error message of the system. You can check its

meaning with a command of the service terminal extension MRS

or in the General Error Messages of System, Supplementary

References

Instructions

Correct the possible failure which is indicated by the failure reason.

Unlock the BCF manually.

Cancelling

No cancelling.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 855 (1095)

7770 AUTOMATIC UNLOCK OF BCF FAILED

Page 856: Alarm

856 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 857: Alarm

3897787 SYNCHRONISATION IS MISSING

Meaning

The synchronisation of the chain or a BCF in the chain is lost.

The synchronisation status of the chain or the BCF is set to

unsynchronised by the system.

In a synchronised BSS the LMU equipment is used as a synchronisation

source for the BCFs in the chain. If the synchronisation of the clock

chain is lost, the alarm affects the master clock BCF of the chain.

If the synchronisation of a slave BCF in the chain is lost, then the alarm

affects only to the slave BCF. This alarm may affect the provided services.

Supplementary information fields

1 identifies the BCF in the chain, the synchronisation of which

is lost. If BCF_ID is same as the id of the master clock of

the chain, the synchronisation of the all BCFs in the chain

is lost.

2 identifies the first BCF in the chain after the LMU. The chain

is identified by the id of the master clock BCF.

Instructions

This alarm is usually a result of a fault situation in the BTS

detected by the BTS or BSC. Use the MML command EOL to list other

alarms affecting the BCF in the chain and act according to their

instructions.

Check that the system cancels the alarms (including this alarm)

which affect the faulty unit.

The alarm indicates that the LMU cannot feed the clock signal to all

BCFs or to some BCF(s) in the chain. The synchronisation status of

the BCF(s) in the chain is not lmu synchronised any more.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 857 (1095)

7787 SYNCHRONISATION IS MISSING

Page 858: Alarm

Check that the system cancels the alarms (including this alarm),

which affects to the faulty unit. This returns the synch status to

synchronised mode.

If the system does not cancel this alarm, lock and unlock the faulty

object (BCF) with the EFS MML command. This causes

a restart of the object. If the object to be unlocked is a master clock

BCF, then the unlock causes that all unlocked BCFs in the chain will

be restarted. Then the system cancels all alarms, which affect the

unit, and if necessary, sets them again. In such a case, correct the

fault according to the instructions in the active alarms which

affect to the unit.

When the BCF is restarted the system cancels all alarms which affect

the BCF and, if necessary, sets them again.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically, when

the fault has been corrected.

858 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 859: Alarm

3907789 NO (E)GPRS TRANSACTIONS INBTS

Meaning

No succesful (E)GPRS transactions have occured within the supervision period

Supplementary information fields

1 Criteria used to detect the (E)GPRS Inactivity.

0 = Alarm disabled

1 = No Successful UL TBFs only

2 = No Successful DL TBFs only

3 = No Successful UL nor DL TBFs

Instructions

Find out the reason for the loss of BTS traffic capacity and bring

the BTS back to use.

Check that the parameters in connection with the alarm are reasonable.

MML commands EQO and EEO outputs the radio network parameter values,

EQV command modifies bts parameter values.

EQO command outputs bts parameters.

EEJ command modifies bsc parameter values.

EEO command outputs bsc parameters.

Parameters, with their default values, affecting the alarm:

ZEQV: EAW = (E)GPRS inactivity alarm weekdays (0)

EAS = (E)GPRS inactivity alarm start time (08-00)

EAE = (E)GPRS inactivity alarm end time (18-00)

ZEEJ: EGIC = (E)GPRS inactivity criteria (0)

IEPH = Number of TBF allocation attemps required per hour (10)

SPL = Supervision period length (60 min)

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 859 (1095)

7789 NO (E)GPRS TRANSACTIONS IN BTS

Page 860: Alarm

Cancelling

The system cancels the (E)GPRS Inactivity Alarm when (E)GPRS traffic

occurs again in the BTS, where the alarm was previously raised.

The user can also cancel the alarm with the EEJ command (criteria = disabled)

860 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 861: Alarm

3917801 MMI CONNECTED TO BASESTATION

Meaning

The MMI-PC is connected to the front-panel connector of the

BCF unit.

This alarm does not affect normal operation.

MMI

The man-machine interface (MMI) is a software used in the PC.

It can be connected to the BCF and it enables doing several

local operations to the BCF.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 861 (1095)

7801 MMI CONNECTED TO BASE STATION

Page 862: Alarm

ADDITIONAL INFORMATION

Fault reason: Local MMI connected

Description: Local BTS Manager is connected to the BTS

Fault reason: Remote MMI connected

Description: Remote BTS Manager is connected to the BTS

via NetAct

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the BTS Manager is disconnected.

862 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 863: Alarm

3927802 LOCALLY LOADED SW SAVED TOBASE STATION

Meaning

This informative alarm is sent to the BSC after locally downloaded

SW has been saved to the flash memory successfully.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 863 (1095)

7802 LOCALLY LOADED SW SAVED TO BASE STATION

Page 864: Alarm

Instructions

The alarm requires no actions.

Cancelling

No cancelling.

864 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 865: Alarm

3937803 LOCAL CONFIGURATION SAVEDTO BASE STATION

Meaning

This informative alarm is sent to the BSC after a change in

the configuration (new HW database) has been saved to the flash

memory successfully.

HW database

The HW database is a file that describes the BCF environment

and default settings.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 865 (1095)

7803 LOCAL CONFIGURATION SAVED TO BASE STATION

Page 866: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

Cancelling

No cancelling.

866 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 867: Alarm

3947804 UNIT TEMPERATURE INCREASED

Meaning

The temperature inside the BCF unit is higher than 60 C.

The cooling fans have been activated.

This is a non-fatal alarm of the BTS.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 867 (1095)

7804 UNIT TEMPERATURE INCREASED

Page 868: Alarm

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

868 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 869: Alarm

3957805 UNIT TEMPERATURE HIGH

Meaning

The temperature inside the BCF unit is higher than 75 C.

The cooling fans have been activated.

This is a non-fatal alarm of the BTS.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 869 (1095)

7805 UNIT TEMPERATURE HIGH

Page 870: Alarm

Instructions

Check the fan units in the same cabinet and the air-conditioning at

the cell site.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

870 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 871: Alarm

3967806 UNIT TEMPERATUREDANGEROUSLY HIGH

Meaning

The temperature inside the BCFA unit is higher than 85 C.

The BTS is switched off to prevent damage to the components.

This is a fatal alarm of the BTS.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 871 (1095)

7806 UNIT TEMPERATURE DANGEROUSLY HIGH

Page 872: Alarm

Instructions

The BCF starts functioning normally when the temperature has gone down.

Check the cabinet fans and the air-conditioning at the cell site.

If the temperature of the BCF is normal and this alarm is still on,

change the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

872 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 873: Alarm

3977807 FAULT IN MMI-INTERFACE OFBASE STATION

Meaning

An MMI UART loop failure. The MMI UART is unable to send data

or to loop sent data.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 873 (1095)

7807 FAULT IN MMI-INTERFACE OF BASE STATION

Page 874: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

874 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 875: Alarm

3987808 FAULT IN Q1-INTERFACE OF BCF

Meaning

A Q1-bus testloop failure. The Q1 UART is unable to send data

or to loop sent data. The control of the units connected to the

Q1 bus is out of order.

If this alarm occurs during Supervisory operation it indicates

that either the Q1-bus UART has become faulty or that a

Q1 connected device is faulty and has jammed the Q1-bus

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 875 (1095)

7808 FAULT IN Q1-INTERFACE OF BCF

Page 876: Alarm

Instructions

This is either an equipment failure at the BCF unit or a faulty Q1

device jamming the Q1-bus.

Try removing Q1 devices one by one. Try replacing TRUx unit.

Retry the looptest by resetting the BCF. If alarms continue to occur,

replace the BCF unit.

Cancelling

The alarm is automatically cancelled by the BSC when the BCF is reset,

or when a faulty Q1 device is remove from the Q1-bus.

876 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 877: Alarm

3997809 FAULT IN DBUS DETECTED BYBCF

Meaning

The BCF does not receive anything from any slave plug-in unit

during the slave poll sequence. The BCF can not control the

plug-in units of the BTS connected to the D-bus, or receive

anything from these plug-in units.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 877 (1095)

7809 FAULT IN DBUS DETECTED BY BCF

Page 878: Alarm

Instructions

Check the D-bus. Replace the BCF unit if the cabling is

done properly.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

878 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 879: Alarm

4007810 FAULT IN WATCH-DOG OF BCF

Meaning

The watchdog cannot reset the BCF.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the setting of the watchdog jumper on the board.

If the watchdog is enabled then replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 879 (1095)

7810 FAULT IN WATCH-DOG OF BCF

Page 880: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

880 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 881: Alarm

4017811 FAULT IN EXTERNAL DIGITALALARM LINE

Meaning

A digital alarm input line failure. The alarm status of this

line is unreliable.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 881 (1095)

7811 FAULT IN EXTERNAL DIGITAL ALARM LINE

Page 882: Alarm

Instructions

First check the cabling of the alarm line. If there are other

alarm lines available, use another line or replace the BCF unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

882 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 883: Alarm

4027812 FAULT IN BCF NON-VOLATILEMEMORY

Meaning

The check sum calculated over a memory block in the flash memory

is invalid, or the stored check sum is corrupted. The code in the

inspected block is probably corrupted.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 883 (1095)

7812 FAULT IN BCF NON-VOLATILE MEMORY

Page 884: Alarm

Instructions

Retry SW downloading to the BCF and saving to the flash memory.

If the alarm is still active replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

884 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 885: Alarm

4037813 MEMORY FAULT IN DBUSINTERFACE OF BCF

Meaning

The BCF is not able to control the units connected to the D-bus.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

(Data failure at BCF -> DBRAM -> DBIA -> DBRAM -> BCF looptest. )

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 885 (1095)

7813 MEMORY FAULT IN DBUS INTERFACE OF BCF

Page 886: Alarm

Instructions

Reset the BCF to retry the loop test. If several tests fail,

replace the BCF.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

886 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 887: Alarm

4047815 FAULT IN BCF NON-VOLATILEMEMORY PROGRAMMING VOLTAGE

Meaning

The programming operation of the flash memory was unsuccessful

due to an illegal program voltage.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 887 (1095)

7815 FAULT IN BCF NON-VOLATILE MEMORY PROGRAMMINGVOLTAGE

Page 888: Alarm

Instructions

The BCF unit is able to operate with old software. If a new

software is required the faulty unit must be replaced before

software downloading.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

888 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 889: Alarm

4057816 NON-VOLATILE MEMORYPROGRAMMING ABORTED IN BCF

Meaning

The operation of the flash memory was unsuccessful due to

an improper command sequence.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 889 (1095)

7816 NON-VOLATILE MEMORY PROGRAMMING ABORTED INBCF

Page 890: Alarm

Instructions

Try to erase memory and reload the BTS software again. If the

operation fails, replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

890 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 891: Alarm

4067817 MASTER CLOCK OVENOSCILLATOR WARMING UP

Meaning

The oven oscillator is in the warm-up condition. The clocks

are not distributed while this alarm is on. The warming of

the oven oscillator normally takes about five minutes.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 891 (1095)

7817 MASTER CLOCK OVEN OSCILLATOR WARMING UP

Page 892: Alarm

Instructions

This alarm is not sent to the BSC or MMI. It is only seen locally

at the front panel display of the BCF-unit. Wait until the MCLG

oscillator is ready. If the alarm remains after 10 minutes replace

the BCF unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

892 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 893: Alarm

4077818 FAULT IN MASTER CLOCK OVENOSCILLATOR

Meaning

The oven oscillator is faulty.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 893 (1095)

7818 FAULT IN MASTER CLOCK OVEN OSCILLATOR

Page 894: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

894 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 895: Alarm

4087820 2.048 MHZ PCM CLOCK IS MISSING

Meaning

The 2.048M PCMA/PCMB clock signal is missing.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 895 (1095)

7820 2.048 MHZ PCM CLOCK IS MISSING

Page 896: Alarm

896 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 897: Alarm

4097821 FRAME CLOCK IS MISSING FROMMASTER CLOCK GENERATOR

Meaning

The frame clock output signal is missing from the master clock

generator of the BCF.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 897 (1095)

7821 FRAME CLOCK IS MISSING FROM MASTER CLOCKGENERATOR

Page 898: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

898 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 899: Alarm

4107822 TIMESLOT CLOCK IS MISSINGFROM MASTER CLOCK GENERATOR

Meaning

The time slot clock output signal is missing from the master clock

generator.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 899 (1095)

7822 TIMESLOT CLOCK IS MISSING FROM MASTER CLOCKGENERATOR

Page 900: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

900 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 901: Alarm

4117823 2 MHZ REFERENCE CLOCK ISMISSING FROM MASTER CLOCKGENERATOR

Meaning

The 2MHz reference clock for the RF unit is missing.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 901 (1095)

7823 2 MHZ REFERENCE CLOCK IS MISSING FROM MASTERCLOCK GENERATOR

Page 902: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

902 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 903: Alarm

4127824 13 MHZ SOURCE CLOCK MISSINGFROM DIV.MASTER CLOCKOSCILLATOR

Meaning

A missing clock pulse has been detected in the redundant 13MHz

clock pulse input. This alarm is relevant only if the redundant

clock generator (BCF unit) is installed.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 903 (1095)

7824 13 MHZ SOURCE CLOCK MISSING FROM DIV.MASTERCLOCK OSCILLATOR

Page 904: Alarm

Instructions

If the redundant clock generator is installed and this alarm

exists replace the redundant BCF unit:

- Replace the redundant BCF unit.

- Wait until the redundant source clock reaches the operating

temperature and the alarm code 7817 is removed from the front

panel display of the redundant BCF unit.

- restart the primary BCF unit

If the alarm still exists replace the primary BCF unit.

If the redundant clock generator is not installed remove the redundant

BCF unit setting in the HW database file.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

904 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 905: Alarm

4137825 13 MHZ SOURCE CLOCK MISSINGFROM MASTER CLOCK OSCILLATOR

Meaning

A missing pulse detected in the 13MHz input. If the redundant BCF unit

has been installed, this alarm is not important.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 905 (1095)

7825 13 MHZ SOURCE CLOCK MISSING FROM MASTER CLOCKOSCILLATOR

Page 906: Alarm

Instructions

Replace the BCF unit. If the redundant BCF is installed, then the

BTS is able to operate normally by using the redundant clock pulse

source.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

906 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 907: Alarm

4147826 13 MHZ CLOCK MISSING FROMMASTER CLOCK GENERATOR

Meaning

A missing pulse detected in the 13MHz output.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 907 (1095)

7826 13 MHZ CLOCK MISSING FROM MASTER CLOCKGENERATOR

Page 908: Alarm

Instructions

Replace the BCF unit. If the redundant BCF is installed, then the

BTS is able to operate by using the redundant clock pulse source.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

908 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 909: Alarm

4157828 ERROR IN FRAME NUMBER INMASTER CLOCK GENERATOR

Meaning

A missing frame number signal output from the MCLG. The TRX units

generate frame numbers automatically if the frame clock pulse is

still available.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 909 (1095)

7828 ERROR IN FRAME NUMBER IN MASTER CLOCKGENERATOR

Page 910: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

910 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 911: Alarm

4167829 FAULT IN ABIS AND DBUSINTERFACE OF BCF

Meaning

The BCF unit is not able to control other BTS units connected to

the D-bus. There is an operational failure in the D-bus interface

This alarm affects the provided services.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 911 (1095)

7829 FAULT IN ABIS AND DBUS INTERFACE OF BCF

Page 912: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

912 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 913: Alarm

4177830 FREQUENCY HOPPING OUT OFORDER

Meaning

The initialisation of the frequency hopping processor has failed.

The BTS is unable to provide service.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 913 (1095)

7830 FREQUENCY HOPPING OUT OF ORDER

Page 914: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

914 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 915: Alarm

4187831 ERROR IN BOOT SOFTWAREDOWNLOADING IN FREQUENCYHOPPING

Meaning

Frequency hopping is not available, because the memory test of the

frequency hopping processor failed.

The BTS is unable to provide service.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 915 (1095)

7831 ERROR IN BOOT SOFTWARE DOWNLOADING INFREQUENCY HOPPING

Page 916: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

916 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 917: Alarm

4197832 TEST FAILED IN INTERNALMEMORY OF FREQUENCY HOPPING

Meaning

The frequency hopping controller has executed a self-test on the

internal memory. A failure has been detected in the self-test.

Frequency hopping is not available.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 917 (1095)

7832 TEST FAILED IN INTERNAL MEMORY OF FREQUENCYHOPPING

Page 918: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

918 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 919: Alarm

4207833 FAILURE IN FREQUENCYHOPPING BUS

Meaning

A data failure in the frequency hopping self-test. Frequency hopping

is not available.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 919 (1095)

7833 FAILURE IN FREQUENCY HOPPING BUS

Page 920: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

920 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 921: Alarm

4217834 FREQUENCY HOPPINGPROCESSOR RESET

Meaning

The frequency hopping processor has stopped. Frequency hopping

is not available.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 921 (1095)

7834 FREQUENCY HOPPING PROCESSOR RESET

Page 922: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

922 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 923: Alarm

4227835 DATA ERROR IN FREQUENCYHOPPING BUS

Meaning

The frequency hopping processor does not receive appropriate frame

numbers from the frame number generator. From now on, the processor

generates frame numbers by itself (clocked by the frame clock).

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 923 (1095)

7835 DATA ERROR IN FREQUENCY HOPPING BUS

Page 924: Alarm

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

924 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 925: Alarm

4237836 TEST FAILED IN EXTERNALMEMORY OF FREQUENCY HOPPING

Meaning

The frequency hopping controller has executed a self-test on

the external memory. A failure has been detected in the self-test.

Frequency hopping is not available.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See Alarm Structure

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 925 (1095)

7836 TEST FAILED IN EXTERNAL MEMORY OF FREQUENCYHOPPING

Page 926: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

926 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 927: Alarm

4247838 13 MHZ SOURCE CLOCKADJUSTMENT REACHING THE LIMITVALUE

Meaning

The BCF controls the frequency of the 13 MHz oven oscillator

within a certain range. The control adjustment has reached a certain

limit (not the maximum value but near it). The control value must

be within the range 5 % ... 95 %, otherwise an alarm is activated.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 927 (1095)

7838 13 MHZ SOURCE CLOCK ADJUSTMENT REACHING THELIMIT VALUE

Page 928: Alarm

Instructions

To avoid problem in the synchronization of this base station

check the quality of the incoming PCM signal and if the PCM signal

is in order replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

928 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 929: Alarm

4257839 DIFFERENCE IN FREQUENCIESBETWEEN PCM AND BTS MASTERCLOCK

Meaning

The BCFA SW compares the 13 MHz frequencey and the PCM reference.

There is a sudden step between the frequencies. The BCF uses the

internal 13 MHz oven frequency instead of the external PCM reference.

The PCM line is usually more unreliable.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 929 (1095)

7839 DIFFERENCE IN FREQUENCIES BETWEEN PCM AND BTSMASTER CLOCK

Page 930: Alarm

Instructions

The alarm requires no actions.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

930 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 931: Alarm

4267840 SW DOWNLOAD TO UNIT FAILED

Meaning

The software download from BCF unit to some other unit of the base

station has failed. The reason for the failure is either an incorrect

software build (package), a transmission failure between units, or

an error in the memory operations of the faulty unit.

The complete base station software builds are downloaded

from the BSC and stored in the non-volatile memory of the BCF unit.

If a unit has downloadable software, the software of the

unit is downloaded from the non-volatile memory of the BCF to the

non-volatile memory of the unit.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initializing the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 931 (1095)

7840 SW DOWNLOAD TO UNIT FAILED

Page 932: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the validity of the downloaded software. If the software is valid

and the connection between the BCF and the unit is in order, reload

the BTS software from the BSC. If this alarm is still active after

reloading, replace the unit.

The faulty unit can be detected by examining the alarm's diagnostic

info field.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

932 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 933: Alarm

4277841 INITIALIZATION OF THE UNITFAILED

Meaning

The BCF unit has failed to initialise some unit of the base station.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initializing the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 933 (1095)

7841 INITIALIZATION OF THE UNIT FAILED

Page 934: Alarm

Instructions

The faulty unit can be detected by examining the alarm's diagnostic

info field. If the diagnostic info field points to equipment which

is not installed in the BTS, check the contents of the HW database.

If the diagnostic info points to equipment which is installed in the

BTS and if the alarm does not disappear automatically, change the

faulty unit.

Use BCF/BTS/TRX lock/unlock or BCF/BTS/TRX reset commands to restart

initialisation.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

934 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 935: Alarm

4287842 NO BCCH TRANSMISSIONACTIVATED

Meaning

The carrier of the broadcast control channel (BCCH) has not been

detected by the combiner.

This alarm affects the provided service. If this alarm is active in

the current BCCH TRX, the cell which the alarming object belongs to

is without BCCH carrier and cannot transmit any traffic.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the TRXs and the combiner of this BTS.

Check also the cables between units. Replace the faulty unit or

correct the fault in cabling. If no faulty units were found and the

cabling between units is in order, replace the unit reported faulty

in the alarm printout.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 935 (1095)

7842 NO BCCH TRANSMISSION ACTIVATED

Page 936: Alarm

Cancelling

To cancel the alarm, give the BLOCK/UNBLOCK command at the cell site

from the OMU-MMI terminal, or the TRX/BTS lock/unlock command remotely

from the BSC-MML terminal.

936 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 937: Alarm

4297850 EXTERNAL FRAME CLOCK ISMISSING

Meaning

The clock oscillator of the BTS generating the master clock is faulty

or the clock interface of the slave BTS is faulty.

If the external frame clock is missing, then the BTS uses its internal

clock signals for synchronisation. Calls can still be maintained.

Cell or site synchronisation

The BTS generating the master clock controls the synchronisation of

the other BTSs on the cell or site.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

This alarm can be caused by a clock alarm in the BTS generating

the master clock. First check the active clock alarms of the BTS

generating the master clock. If the BTS generating the master clock

has no active clock alarms, then check the connection of the extension

clock cable of the slave BTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 937 (1095)

7850 EXTERNAL FRAME CLOCK IS MISSING

Page 938: Alarm

If the extension clock cable is fastened correctly to the slave BTS

and this alarm still remains active, then replace the slave BTS.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

938 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 939: Alarm

4307851 EXTERNAL FRAME NUMBER ISMISSING

Meaning

The clock oscillator of the BTS generating the master clock is faulty

or the clock interface of the slave BTS is faulty.

If the external frame number is missing, then the BTS uses its internal

clock signals for synchronisation. Calls can still be maintained.

Cell or site synchronisation

The BTS generating the master clock controls the synchronisation of

the other BTSs on the cell or site.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

This alarm can be caused by a clock alarm in the BTS generating the

master clock. First check the active clock alarms of the BTS generating

the master clock. If the BTS generating the master clock has no active

clock alarms, then check the connection of the extension clock cable of

the slave BTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 939 (1095)

7851 EXTERNAL FRAME NUMBER IS MISSING

Page 940: Alarm

If the extension clock cable is fastened correctly to the slave BTS

and this alarm still remains active, then replace the slave BTS.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

940 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 941: Alarm

4317852 BTS HEATER FAILURE

Meaning

The BTS heater is faulty.

BTS heater

The heater maintains the BTS-internal temperature on a sufficient

level for operation.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the BTS.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 941 (1095)

7852 BTS HEATER FAILURE

Page 942: Alarm

942 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 943: Alarm

4327853 TEMPERATURE DANGEROUSLYHIGH

Meaning

The temperature inside the BTS is dangerously high. The BTS is

automatically switched off to prevent damages to components.

Calls are not available.

The BTS restarts after the temperature inside the BTS has decreased

sufficiently.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The temperature of the BTS operating environment must be within the

specified limits (See BTS Customer Documents).

The BTS may be dirty or faulty.

If the temperature of the BTS returns to normal, this alarm disappears.

Replace the BTS if this alarm does not disappear and the temperature of

the BTS operating environment is not within the specified limits.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 943 (1095)

7853 TEMPERATURE DANGEROUSLY HIGH

Page 944: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

944 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 945: Alarm

4337854 TEMPERATURE INCREASED

Meaning

Temperature inside the BTS has risen to first temperature alarm level.

Either the ambient temperature has increased too high or the BTS may

have a problem.

Calls are still available.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The alarm requires no actions.

If the temperature of the BTS returns to normal level,

this alarm disappears. If the temperature keeps increasing, the BTS

issues a fatal alarm.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 945 (1095)

7854 TEMPERATURE INCREASED

Page 946: Alarm

946 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 947: Alarm

4347860 NO CONNECTION TOTRANSMISSION UNIT

Meaning

The transmission unit (TRU) or a redundant TRU 2 does not respond to

the poll command from the BCFA unit on the Q1 bus. Connection to the

TRU is broken or unit is not inserted.

This alarm can affect the provided service of the BTS or of the

transmission network. The current status of the transmission unit is

not known and obviously the commands to the TRU do not reach the TRU.

Transmission unit (TRU) is the PCM equipment of the BTS.It connects

the BTS to the transmission network. The TRU or its redundant unit

carries all speech, data and signalling traffic of the BTS towards

the BSC or other BTSs.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The unit which does not respond can be detected by examining

the alarm's diagnostic info field. If the supplementary information

fields point to equipment which is not installed to the BTS, check

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 947 (1095)

7860 NO CONNECTION TO TRANSMISSION UNIT

Page 948: Alarm

the contents of the HW database. If the diagnostic info points to a

unit which is installed to the BTS, check the parameters of the unit.

If the parameters are in order replace the TRU unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

948 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 949: Alarm

4357861 SERVICE TERMINAL CONNECTEDTO ABIS TRANSMISSION EQUIPMENT

Meaning

The service terminal is connected to the TRUx front panel connector.

This disconnects the BTS Q1 bus and thus blocks the alarms from the

TRUx and the RRxx.

This alarm affects to provided services.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see instructions on Alarm Structure.

Instructions

The remote connection is disconnected until service terminal is removed

from Q1 bus.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 949 (1095)

7861 SERVICE TERMINAL CONNECTED TO ABISTRANSMISSION EQUIPMENT

Page 950: Alarm

950 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 951: Alarm

4367868 FAULT IN MAIN RX BRANCH OFREDUNDANT TRX SWITCH

Meaning

A receiver amplifier failure in the FTS's redundant TRX main branch.

The main branch in the redundant TRX is broken.

If diversity is not connected, the whole redundant TRX is out of use.

If diversity is connected, the diversity branch replaces the

main branch.

FTS

The Floating Transceiver Switch (FTS) is used to switch the redundant

transceiver to replace the broken BCCH transceiver. It is similar to

a relay that connects the new TRX to the same antenna that the broken

TRX had been using.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty TRX or the FTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 951 (1095)

7868 FAULT IN MAIN RX BRANCH OF REDUNDANT TRX SWITCH

Page 952: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

952 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 953: Alarm

4377870 CABINET DOOR OPEN

Meaning

The cabinet door is open.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Close the cabinet door.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 953 (1095)

7870 CABINET DOOR OPEN

Page 954: Alarm

954 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 955: Alarm

4387872 CABINET TEMPERATURE TOOHIGH

Meaning

The cooling system of the BTS is not able to maintain the appropriate

temperature level in a cabinet. Temperature in the cabinet is above

the range of the operating temperature.

The heat exchanger control unit (HCU) is an air-conditioning device

for keeping the temperature of the BTS cabinet within the operational

limits.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See instructions on Alarm Structure

Instructions

Check the ventilation of the cabinet and check the operation of the

HCU. If a HCU malfunction is detected then replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 955 (1095)

7872 CABINET TEMPERATURE TOO HIGH

Page 956: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

956 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 957: Alarm

4397873 CABINET TEMPERATURE TOOLOW

Meaning

The heating system of the BTS is not able to maintain appropriate

temperature level in the cabinet. Temperature in the cabinet is

below the range of the operating temperature.

The heat exchanger control unit (HCU) is an air-conditioning device

for keeping the temperature of the BTS cabinet within the operational

limits.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the heater in the cabinet and check the

operation of the HCU. Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 957 (1095)

7873 CABINET TEMPERATURE TOO LOW

Page 958: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

958 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 959: Alarm

4407874 TEMPERATURE CONTROLLINGDEVICE FAULTY

Meaning

The heat control unit (HCU) is fatally faulty due to a HW failure

in unit.

This alarm does not affect the provided services of the base station.

The HCU is an air-conditioning device for keeping the temperature

of the BTS cabinet within the operational limits.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the Heat Controlling Unit (HCU) and change the

unit when needed.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 959 (1095)

7874 TEMPERATURE CONTROLLING DEVICE FAULTY

Page 960: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

960 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 961: Alarm

4417875 EXTERNAL BTSSYNCHRONISATION SOURCE ISMISSING

Meaning

BTS has detected that the external clock signals from a master BTS or LMU are

missing.

This situation will cause an immediate system outage.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure.

Instructions

Instructions:

1. Check the synchronisation cabling.

2. Check the synchronisation source (Master BCF or Location Measurement

Unit (LMU)).

3. If 1. & 2. above are OK, replace the BCFB.

4. Restart BCF.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 961 (1095)

7875 EXTERNAL BTS SYNCHRONISATION SOURCE IS MISSING

Page 962: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

962 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 963: Alarm

4427876 LMU: EXTERNALSYNCHRONISATION SIGNALSDISABLED

Meaning

The Location Measurement Unit (LMU) has reported that the clock

synchronisation signals to the BTS are about to be disabled.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see Alarm Structure.

Instructions

The alarm 7876 will be preceded by the Location Management Unit (LMU)

raising alarm 8048, indicating the Global Positioning System (GPS)

signal lock has been lost. Check that the GPS Antenna is connected to

the LMU and that the GPS Antenna has a clear view of the sky.

On raising alarm 7876, the BSS Site Synchronisastion recovery actions

will automatically be made by the BTS / BSC.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 963 (1095)

7876 LMU: EXTERNAL SYNCHRONISATION SIGNALS DISABLED

Page 964: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically when

the fault has been corrected.

964 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 965: Alarm

4437878 SERIAL LINK FAULTY IN FREQ.HOPPING PROCESSOR

Meaning

A fault was detected in the serial input/output line of the frequency

hopping processor in the BCFA unit during the self-test of the processor.

The alarm affects the provided services of the cell site because

the BCF unit is faulty.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising of the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 965 (1095)

7878 SERIAL LINK FAULTY IN FREQ. HOPPING PROCESSOR

Page 966: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

966 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 967: Alarm

4447879 SW DOWNLOADING TO FREQ.HOPPING PROCESSOR FAILED

Meaning

The software downloading to the frequency hopping processor

in the BCFA unit has failed. The BTS is unable to provide service.

This alarm affects the provided services if frequency hopping

is used.

BCF

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising of the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 967 (1095)

7879 SW DOWNLOADING TO FREQ.HOPPING PROCESSORFAILED

Page 968: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

968 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 969: Alarm

4457880 CONFIGURATION FAILURE INFREQ. HOPPING PROCESSOR

Meaning

The frequency hopping processor has noticed that the parameters

received for the frequency hopping are not correct.

This alarm affects the provided services if the frequency hopping

is used.

The frequence hoping processor handles the hopping sequences of the

hopping BTS. This processor is placed in the BCF unit.

The base control function (BCF) unit is responsible for the

operation and maintenance of the BTS. The main functions of

the BCF are: loading of the BTS operational file packets from

the BSC to the BTS, initialising of the BTS, continuous supervision

of the BTS equipment, reporting faults to the BSC and testing

and operating functions.

The BCF is also the source of main clock pulses of the BTS.

The BCF also controls the frequency hopping operations of the

BTS. The connection of the BTS's user interface is at the front

panel of the BCF unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 969 (1095)

7880 CONFIGURATION FAILURE IN FREQ. HOPPINGPROCESSOR

Page 970: Alarm

Instructions

Check the hopping parameters used.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

970 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 971: Alarm

4467882 SMOKE DETECTED IN CABINET

Meaning

Smoke is detected in the BTS cabinet.

This alarm may indicate an urgent situation on the cell site.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check immediately the source of the smoke.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 971 (1095)

7882 SMOKE DETECTED IN CABINET

Page 972: Alarm

972 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 973: Alarm

4477890 FAULT IN COOLING FAN

Meaning

One of the fan units in the cooling fan chain fails to operate.

The BTS units are still able to operate, but temperatures may rise

too much.

CFU

The cooling fan unit (CFU) is the cooler of the BTS unit.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 973 (1095)

7890 FAULT IN COOLING FAN

Page 974: Alarm

974 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 975: Alarm

4487891 SITE TEST MONITOR OUT OFORDER

Meaning

A failure in the STM hardware. The BTS radio frequency loop tests are

not available.

STM

The site test and measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 975 (1095)

7891 SITE TEST MONITOR OUT OF ORDER

Page 976: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

976 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 977: Alarm

4497892 SITE TEST MONITOR CAN NOTFIND BCCH CARRIER

Meaning

The test unit is not able to find the BCCH channel of the BTS. There

may be a failure in the BCCH transmitter, or the STM is out of order.

STM

The site test and measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check if the BCCH transmitter is active. There should be no 'Forward

power too low' nor 'No BCCH transmission activated' alarm active at

the combiner.

If the BCCH transmitter is active, replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 977 (1095)

7892 SITE TEST MONITOR CAN NOT FIND BCCH CARRIER

Page 978: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

978 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 979: Alarm

4507893 FAULT IN DBUS INTERFACE OFSITE TEST MONITOR

Meaning

The interface to the control bus is unreliable. The BCF unit is not

able to control the STM via the D-bus.

STM

The site test and measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 979 (1095)

7893 FAULT IN DBUS INTERFACE OF SITE TEST MONITOR

Page 980: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

980 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 981: Alarm

4517894 FAULT IN INTERNAL BUS OF SITETEST MONITOR

Meaning

The STM uses the internal measurement and control bus to execute

radio frequency tests. A fault has been detected in this internal bus.

STM

The site test and measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 981 (1095)

7894 FAULT IN INTERNAL BUS OF SITE TEST MONITOR

Page 982: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

982 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 983: Alarm

4527895 FAULT IN MEMORY OF SITE TESTMONITOR

Meaning

The STM automatically executes some self-tests to ensure proper

operation. A failure has been detected in the STM memory tests.

The STM is not able to operate anymore.

STM

The site test and measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 983 (1095)

7895 FAULT IN MEMORY OF SITE TEST MONITOR

Page 984: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

984 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 985: Alarm

4537896 FAULT IN DBUS INTERFACE OFSITE TEST MONITOR

Meaning

The interface to the control bus is unreliable (BSIA-ASIC failure).

The BCF unit is not able to control the STM via the D-bus.

STM

The site test mnd Measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 985 (1095)

7896 FAULT IN DBUS INTERFACE OF SITE TEST MONITOR

Page 986: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

986 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 987: Alarm

4547897 FAULT IN NON-VOLATILE MEMORYOF SITE TEST MONITOR

Meaning

The STM automatically executes some self-tests to ensure proper

operation. A failure has been detected in the tests of the STM's

non-volatile (flash) memory. The STM is able to operate in spite

of this alarm.

STM

The site test and measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 987 (1095)

7897 FAULT IN NON-VOLATILE MEMORY OF SITE TESTMONITOR

Page 988: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

988 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 989: Alarm

4557898 SIM-CARD OF SITE TEST MONITORDOES NOT WORK

Meaning

The STM automatically executes some self-tests to ensure proper

operation. A failure has been detected in the SIM card tests.

The STM is not able to operate if the SIM card is not installed

or if it is broken.

STM

The site test mnd Measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the SIM card.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 989 (1095)

7898 SIM-CARD OF SITE TEST MONITOR DOES NOT WORK

Page 990: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

990 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 991: Alarm

4567899 MEMORY FAULT IN DBUSINTERFACE OF SITE TEST MONITOR

Meaning

The interface to the control bus is unreliable. The BCF unit is not

able to control the STM via the D-bus. The STM is not available anymore.

STM

The site test and measurement unit (STM) enables radio interface testing

of the BTS. It has many functions similar to a ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio interface.

A fatal failure in the STM does not affect the normal operation of the

BTS site, but several BTS tests may be excluded, if a fatal failure of

the STM has been detected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 991 (1095)

7899 MEMORY FAULT IN DBUS INTERFACE OF SITE TESTMONITOR

Page 992: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

992 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 993: Alarm

4577900 NO CONNECTION TO TRX

Meaning

The TRX unit does not response to the poll command from the BCFA unit

on the D-bus. Connection to the TRX unit is broken or the unit is not

available.

This alarm affects the provided services of the TRX.

The TRX has four main tasks. It is the air interface of the base

station, it handles the signalling between the base station

controller and the mobile station and it relays all traffic

between the A-bis-interface and the air interface. It also performs

all baseband operations for traffic data, for example encryption,

decryption, coding, decoding and demodulation, and combining the two

branches in case of antenna diversity.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The unit which does not respond can be detected by examining

the alarm's supplementary information field. If the supplementary

info field points to equipment which is not installed to the BTS,

check the contents of the HW database. If the diagnostic info points

to equipment which is installed to the BTS, change the unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 993 (1095)

7900 NO CONNECTION TO TRX

Page 994: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

994 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 995: Alarm

4587905 SITE TEST MONITOR NOTOPERATING

Meaning

Selftest of the site test monitor (STM) has detected a failure

in the operation of the STM unit.

A fatal failure in the STM does not affect the normal operation of the

BTS site. This alarm affect the tests of the BTS.

The site test monitor unit (STM) enables radio interface testing

of the BTS. It has many functions similar to an ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio

interface.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 995 (1095)

7905 SITE TEST MONITOR NOT OPERATING

Page 996: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

996 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 997: Alarm

4597906 FAILURE IN RF COUPLING OF SITETEST MONITOR

Meaning

The selftest of the site test monitor (STM) has detected a failure

in the operation of the STM RF coupling module.

A fatal failure in the STM does not affect the normal operation of

the BTS site. This alarm affects the tests of the BTS.

The site test monitor unit (STM) enables radio interface testing

of the BTS. It has many functions similar to an ordinary mobile

phone. Additionally, there are measurement functions for the BTS

radio interface.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 997 (1095)

7906 FAILURE IN RF COUPLING OF SITE TEST MONITOR

Page 998: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

998 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 999: Alarm

4607907 +7 V POWER SUPPLY FAULTY INSITE TEST MONITOR UNIT

Meaning

The selftest of the site test monitor (STM) has detected a failure

in the operation of the +6 V power supply.

A fatal failure in the STM does not affect the normal operation of the

BTS site. This alarm affects the tests of the BTS.

The site test monitor unit (STM) enables radio interface testing

of the BTS. It has many functions similar to an ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio

interface.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 999 (1095)

7907 +7 V POWER SUPPLY FAULTY IN SITE TEST MONITORUNIT

Page 1000: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1000 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1001: Alarm

4617908 +12 V POWER SUPPLY FAULTY INSITE TEST MONITOR UNIT

Meaning

The selftest of the site test monitor (STM) has detected a failure

in the operation of the +12 V power supply.

A fatal failure in the STM does not affect the normal operation of the

BTS site. This alarm affects the tests of the BTS.

The site test monitor unit (STM) enables radio interface testing

of the BTS. It has many functions similar to an ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio

interface.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1001 (1095)

7908 +12 V POWER SUPPLY FAULTY IN SITE TEST MONITORUNIT

Page 1002: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1002 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1003: Alarm

4627909 -12 V POWER SUPPLY FAULTY INSITE TEST MONITOR UNIT

Meaning

The selftest of the site test monitor (STM) has detected a failure

in the operation of the -12 V power supply.

A fatal failure in the STM does not affect the normal operation of the

BTS site. This alarm affects the tests of the BTS.

The site test monitor unit (STM) enables radio interface testing

of the BTS. It has many functions similar to an ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio

interface.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the STM unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1003 (1095)

7909 -12 V POWER SUPPLY FAULTY IN SITE TEST MONITORUNIT

Page 1004: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1004 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1005: Alarm

4637937 UNIT TEMPERATUREDANGEROUSLY HIGH

Meaning

The temperature inside the AFE unit is higher than 100 C.

Calls going via the transmitter and connected to this AFE are not

availabe.

AFE

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The BTS sector must be switched off to prevent damage to the

components. Wait until the combiner has cooled down. Check the

cooling systems and the ventilation of the cabinet.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1005 (1095)

7937 UNIT TEMPERATURE DANGEROUSLY HIGH

Page 1006: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1006 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1007: Alarm

4647939 FORWARD POWER TOO LOW ATTX ANTENNA

Meaning

There is no transmission power at the TX antenna connection of

the AFE unit.The missing power indicates a failure at the non-BCCH

transmission and the amount of the channels for the signalling and

traffic is reduced in this BTS sector.

AFE

Transmitting

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Receiving

The antenna filter unit (AFE) filters and amplifies the signal

received from the receiving antenna. The amplified output signals

are connected to the receivers of the BTS. Each AFE contains two

low noice amplifiers (LNA), one for the main and one for the

diversity receiving path. One LNA contains two different amplifier

branches. The LNA is out of order if both of those amplifier

branches are faulty

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1007 (1095)

7939 FORWARD POWER TOO LOW AT TX ANTENNA

Page 1008: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

This alarm is reported as result of the AFE supervision test.

Check the TRX transmitters and the cabling between the transmitter

and the AFE unit. If both are in order the AFE unit is faulty.

Replace the faulty unit. The error is fixed after the AFE

supervision test is passed without this alarm.

Cancelling

To cancel this alarm, lock and unlock the BTS from the BSC or

run the AFE supervision test again without errors from the MMI.

1008 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1009: Alarm

4657941 TX ANTENNA PERFORMANCEDEGRADED

Meaning

The standing wave ratio of the TX-antenna is above the adjustable

lower alarm level. The antenna adjustment is unbalanced. Calls can

still be maintained. This alarm can also be caused by snow and ice

on the antenna.

AFE

Transmitting

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Receiving

The antenna filter unit (AFE) filters and amplifies the signal

received from the receiving antenna. The amplified output signals

are connected to the receivers of the BTS. Each AFE contains two

low noice amplifiers (LNA), one for the main and one for the

diversity receiving path. One LNA contains two different amplifier

branches. The LNA is out of order if both of those amplifier

branches are faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1009 (1095)

7941 TX ANTENNA PERFORMANCE DEGRADED

Page 1010: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the AFE unit, antenna, and cabling

between the AFE unit and antenna. Replace the faulty unit.

The alarm level is adjustable in the HW database.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1010 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1011: Alarm

4667942 TX ANTENNA FAULTY

Meaning

The standing-wave ratio of the TX antenna is above the higher alarm

level. The antenna adjustment is badly unbalanced. Calls can not be

maintained. This alarm can also be caused by an antenna failure.

If there is no other AFE unit in the same BTS sector calls can not

be maintained through this BTS sector.

AFE

Transmitting

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Receiving

The antenna filter unit (AFE) filters and amplifies the signal

received from the receiving antenna. The amplified output signals

are connected to the receivers of the BTS. Each AFE contains two

low noice amplifiers (LNA), one for the main and one for the

diversity receiving path. One LNA contains two different amplifier

branches. The LNA is out of order if both of those amplifier

branches are faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1011 (1095)

7942 TX ANTENNA FAULTY

Page 1012: Alarm

Instructions

Check the operation of the AFE unit, antenna, and cabling

between the AFE unit and antenna. Replace the faulty unit.

The alarm level is adjustable in the HW database.

Cancelling

To cancel the alarm, use the BTS reset command from the MMI or the

lock/unlock command from the BSC MML terminal.

1012 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1013: Alarm

4677943 FAULT IN MAIN BRANCH LNA OFANTENNA FILTER UNIT

Meaning

One of the parallel amplifiers is broken in the low noise amplifier

(LNA) of the main receiving path in the AFE. The BTS RF receiving

capability is reduced.

In a configuration of the one AFE unit per sector this alarm affects

the whole BTS sector. If two AFEs is used per sector this alarm

affects only part of the BTS sector.

AFE

Transmitting

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Receiving

The antenna filter unit (AFE) filters and amplifies the signal

received from the receiving antenna. The amplified output signals

are connected to the receivers of the BTS. Each AFE contains two

low noice amplifiers (LNA), one for the main and one for the

diversity receiving path. One LNA contains two different amplifier

branches. The LNA is out of order if both of those amplifier

branches are faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1013 (1095)

7943 FAULT IN MAIN BRANCH LNA OF ANTENNA FILTER UNIT

Page 1014: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the unit unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1014 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1015: Alarm

4687944 MAIN BRANCH LNA OUT OFORDER IN ANTENNA FILTER UNIT

Meaning

Both amplifier branches are broken in the low noise amplifier (LNA)

of the main receiving path in the AFE. The main RX does not work

in those TRXs which are connected to the main receiving path of

this AFE unit.In a configuration of the one AFE per sector the whole

BTS sector is without main path receiving but in a configuration

of the two AFE unit per sector only part of sector is without

main path receiving.

AFE

Transmitting

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Receiving

The antenna filter unit (AFE) filters and amplifies the signal

received from the receiving antenna. The amplified output signals

are connected to the receivers of the BTS. Each AFU contains two

low noise amplifiers (LNA), one for the main and one for diversity

receiving path. One LNA contains two different amplifier branches.

The LNA is out of order if both of those amplifier branches are

faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1015 (1095)

7944 MAIN BRANCH LNA OUT OF ORDER IN ANTENNA FILTERUNIT

Page 1016: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1016 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1017: Alarm

4697945 FAULT IN DIVERSITY BRANCH LNAOF ANTENNA FILTER UNIT

Meaning

One of the parallel amplifiers is broken in the low noise

amplifier (LNA) of the diversity receiving path in the AFE.

The BTS RF receiving capability is reduced.

In a configuration of the one AFE unit per sector this alarm affects

the whole BTS sector. If two AFEs is used per sector this alarm

affects only part of the BTS sector.

AFE

Transmitting

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Receiving

The antenna filter unit (AFE) filters and amplifies the signal

received from the receiving antenna. The amplified output signals

are connected to the receivers of the BTS. Each AFE contains two

low noise amplifiers (LNA), one for the main and one for diversity

receiving path. One LNA contains two different amplifier branches.

The LNA is out of order if both of those amplifier branches are

faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1017 (1095)

7945 FAULT IN DIVERSITY BRANCH LNA OF ANTENNA FILTERUNIT

Page 1018: Alarm

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1018 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1019: Alarm

4707946 DIVERSITY BRANCH LNA OUT OFORDER IN ANTENNA FILTER UNIT

Meaning

Both amplifier branches are broken in the low noise amplifier (LNA)

of the diversity receiving path in the AFE. The diversity RX does not

work in those TRXs which are connected to the diversity receiving

path of this AFE unit.In a configuration of the one AFE per sector

the whole BTS sector is without diversity path receiving but in a

configuration of the two AFE unit per sector only part of sector

is without diversity path receiving.

AFE

Transmitting

The antenna filter unit (AFE) combines one or two transmitters to

one single transmitting antenna. The AFE also filters transmitter

signals to reach better signal quality.

Receiving

The antenna filter unit (AFE) filters and amplifies the signal

received from the receiving antenna. The amplified output signals

are connected to the receivers of the BTS. Each AFE contains two

low noise amplifiers (LNA), one for the main and one for diversity

receiving path. One LNA contains two different amplifier branches.

The LNA is out of order if both of those amplifier branches are

faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1019 (1095)

7946 DIVERSITY BRANCH LNA OUT OF ORDER IN ANTENNAFILTER UNIT

Page 1020: Alarm

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1020 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1021: Alarm

4717947 MAIN BRANCH MAST HEADPREAMPLIFIER OUT OF ORDER

Meaning

A failure in the mast head preamplifier (MHP). The amplifier has been

automatically passed by the MHP, and the receiving sensitivity has been

decreased by several dBs due to cable losses.

MHP

The mast head preamplifier (MHP) amplifies the received signal. This

amplification compensates the receiver cable losses.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the MHP.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1021 (1095)

7947 MAIN BRANCH MAST HEAD PREAMPLIFIER OUT OFORDER

Page 1022: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1022 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1023: Alarm

4727948 DIVERSITY BRANCH MAST HEADPREAMPLIFIER OUT OF ORDER

Meaning

A failure in the receiver amplifier of the diversity mast head

preamplifier (MHP). The amplifier has been automatically passed

by the MHP, and the receiving sensitivity has been decreased by

several dBs due to cable losses.

MHP

The mast head preamplifier (MHP) amplifies the received signal. This

amplification compensates the receiver cable losses.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the MHP.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1023 (1095)

7948 DIVERSITY BRANCH MAST HEAD PREAMPLIFIER OUT OFORDER

Page 1024: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1024 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1025: Alarm

4737949 DIFFERENCE IN RX LEVELS OFMAIN AND DIVERSITY ANTENNA / TRX

Meaning

Difference of Rx signal strength between main and diversity

antennas is higher than the limit value (default 10 dB).

The BCF or OMU receives the limit value in BTS_CONF_DATA

message from the BSC. If the BSC does not send the value,

10 dB is used as a default value.

The Rx antenna monitoring is supported in Nokia 2nd generation,

Nokia Talk Family (all configurations with diversity) and

Nokia PrimeSite base stations.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

You cancel the alarm if the calculated Rx signal strength

difference between main and diversity antennas is at least

2 dB less than the limit value.

For Talk-family the subunit number has the following meaning

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1025 (1095)

7949 DIFFERENCE IN RX LEVELS OF MAIN AND DIVERSITYANTENNA / TRX

Page 1026: Alarm

1 Antenna Fault difference

2 TRX Branch difference

3 RX Relative difference

Cancelling

Do not cancel the alarm. The system cancels the alarm

automatically when the fault has been corrected.

1026 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1027: Alarm

4747950 NO CONNECTION TO REMOTETUNE COMBINER

Meaning

The remote tune combiner (RTC) does not response to the poll command

from the BCFA unit on the D-Bus. Connection to the RTC is broken or

the unit is not inserted.

This alarm affects the provided service. The BTS of the BCF

is not working.

The remote tune combiner unit (RTC) combines the signals of

several transmitters to one single transmitting antenna. The RTC

supplies lower signal losses compared to a non-tunable antenna

filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The unit which does not respond can be detected by examining

the alarm's supplementary information field. If the supplementary

info field points to equipment which is not installed to the BTS,

check the contents of the HW database. If the diagnostic info points

to equipment which is installed to the BTS, change the unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1027 (1095)

7950 NO CONNECTION TO REMOTE TUNE COMBINER

Page 1028: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1028 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1029: Alarm

4757952 TUNING FAILED IN CAVITY OFREMOTE TUNE COMBINER

Meaning

The tuning of a certain cavity has failed. This may happen in the

initial tuning operation of the RTC (the RTC never reaches the

appropriate RF-channel). Another possibility is that for some reason

the RTC looses the tuned channel. The alarm is activated in both of

these cases. Calls going via the transmittter and connected to this

cavity are not availabe.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter (AFU).

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If the BCCH transmitter is connected to this combiner cavity,

reconfigure the BTS so that the BCCH is connected to a cavity

that is able to work.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1029 (1095)

7952 TUNING FAILED IN CAVITY OF REMOTE TUNE COMBINER

Page 1030: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1030 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1031: Alarm

4767953 TX ANTENNA PERFORMANCEDEGRADED

Meaning

The standing-wave ratio of the TX antenna is above the adjustable

lower alarm level. The antenna adjustment is unbalanced. Calls can

still be maintained. This alarm can also be caused by snow and ice

on the antenna.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the combiner and the cabling between

the combiner and antenna and replace the faulty unit if needed.

If everything is in order check the antenna. The alarm level is

adjustable in the HW database.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1031 (1095)

7953 TX ANTENNA PERFORMANCE DEGRADED

Page 1032: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1032 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1033: Alarm

4777954 TX ANTENNA FAULTY

Meaning

The standing-wave ratio of the TX antenna is above the higher alarm

level. The antenna adjustment is unbalanced. Calls cannot be maintained.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the combiner and the cabling between

the combiner and antenna and replace the faulty unit if needed.

If everything is in order check the antenna. The alarm level is

adjustable in the HW database.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1033 (1095)

7954 TX ANTENNA FAULTY

Page 1034: Alarm

Cancelling

To cancel this alarm, use the BTS reset command from the MMI or the

or BTS lock/unlock command from the BSC MML terminal.

1034 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1035: Alarm

4787955 SYNTHESIZER OUT OF ORDER INREMOTE TUNE COMBINER

Meaning

The internal tuning synthesiser of the RTC is out of order. All

transmitters has been switched off, and calls are not available via

this combiner.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1035 (1095)

7955 SYNTHESIZER OUT OF ORDER IN REMOTE TUNECOMBINER

Page 1036: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1036 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1037: Alarm

4797956 CONTROLLER OUT OF ORDER INREMOTE TUNE COMBINER

Meaning

The internal controller RTC is out of order. All transmitters

are switched off and calls are not available via this combiner.

RTC

The remotely tunable combiner unit (RTC) combines several

transmitters to one single transmitting antenna. The RTC enables

lower signal losses compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1037 (1095)

7956 CONTROLLER OUT OF ORDER IN REMOTE TUNECOMBINER

Page 1038: Alarm

Cancelling

Cancel the alarm with the EOR command after correcting

the fault as presented in INSTRUCTIONS.

1038 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1039: Alarm

4807957 FAULT IN +5V POWER SUPPLY OFREMOTE TUNE COMBINER

Meaning

The +5V power supply of the RTC has changed its voltage level

by >6% (includes complete failure). Calls are not available via

this combiner.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the power supplies and the power cabling of the BTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1039 (1095)

7957 FAULT IN +5V POWER SUPPLY OF REMOTE TUNECOMBINER

Page 1040: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1040 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1041: Alarm

4817958 FAULT IN +12V POWER SUPPLY OFREMOTE TUNE COMBINER

Meaning

The +12V power supply of the RTC has changed its voltage level

by >6% (includes complete failure). Calls are not available via

this combiner.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the power supplies and the power cabling of the BTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1041 (1095)

7958 FAULT IN +12V POWER SUPPLY OF REMOTE TUNECOMBINER

Page 1042: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1042 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1043: Alarm

4827959 FAULT IN -12V POWER SUPPLY OFREMOTE TUNE COMBINER

Meaning

The -12V power supply of the RTC has changed its voltage level

by >6% (includes complete failure). Calls are not available via

this combiner.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the power supplies and the power cabling of the BTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1043 (1095)

7959 FAULT IN -12V POWER SUPPLY OF REMOTE TUNECOMBINER

Page 1044: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1044 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1045: Alarm

4837960 FAULT IN +26V POWER SUPPLY OFREMOTE TUNE COMBINER

Meaning

The +26V power supply of the RTC has changed its voltage level

by >13% (includes complete failure). Calls are not available via

this combiner.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the power supplies and the power cabling of the BTS.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1045 (1095)

7960 FAULT IN +26V POWER SUPPLY OF REMOTE TUNECOMBINER

Page 1046: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1046 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1047: Alarm

4847961 TUNING CARRIER NOT PRESENTIN REMOTE TUNE COMBINER

Meaning

The tuning command has been sent to the RTC, but all necessary

transmitters are not sending the RF at the appropriate power level

(level 8) or not at all.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the TRXs and the cabling between the TRXs and

the combiner. If everything is in order the combiner is faulty.

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1047 (1095)

7961 TUNING CARRIER NOT PRESENT IN REMOTE TUNECOMBINER

Page 1048: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1048 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1049: Alarm

4857962 PERIODICAL CAVITY TEST FAILED,CAVITY NOT AVAILABLE

Meaning

The RTC executes a self-test for unused cavities periodically. This test

is done to make sure that the step motor of the cavity is not stuck.

The alarm indicates that motor is not able to do tuning operations.

This RTC cavity is not available, but calls are available via other

cavities.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the RTC if the faulty cavity is used.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1049 (1095)

7962 PERIODICAL CAVITY TEST FAILED, CAVITY NOTAVAILABLE

Page 1050: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1050 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1051: Alarm

4867963 CAVITY RESET FAILED, CAVITYNOT AVAILABLE

Meaning

The reset command has been sent to the RTC cavity, but the RTC is

not able to run the cavity into the reset position. This cavity is

unavailable, and the TRX must not be connected to it.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

If there is free cavity in the RTC connect the TRX of the faulty cavity

to this free cavity. If there is no free cavity in the RTC

replace the RTC.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1051 (1095)

7963 CAVITY RESET FAILED, CAVITY NOT AVAILABLE

Page 1052: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1052 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1053: Alarm

4877964 FAULT IN NON-VOLATILE MEMORYOF REMOTE TUNE COMBINER

Meaning

The RTC automatically executes some self-tests in order to ensure

proper operation. A failure has been detected in the tests of the

RTC's non-volatile (flash) memory. The RTC is able to operate in

spite of this alarm.

RTC

The remotely tunable combiner unit (RTC) combines several

transmitters to one single transmitting antenna. The RTC enables

lower signal losses compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1053 (1095)

7964 FAULT IN NON-VOLATILE MEMORY OF REMOTE TUNECOMBINER

Page 1054: Alarm

Cancelling

Cancel the alarm with the EOR command after correcting

the fault as presented in INSTRUCTIONS.

1054 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1055: Alarm

4887965 MEMORY FAULT IN DBUSINTERFACE OF REMOTE TUNECOMBINER

Meaning

The RTC automatically executes some self-tests in order to ensure

proper operation. A failure has been detected in the tests of the

RTC's dual-port ram memory. The BCF unit is not able to control

the operation of the RTC and tuning of the RTC is impossible.

RTC

The remotely tunable combiner unit (RTC) combines several

transmitters to one single transmitting antenna. The RTC enables

lower signal losses compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1055 (1095)

7965 MEMORY FAULT IN DBUS INTERFACE OF REMOTE TUNECOMBINER

Page 1056: Alarm

Cancelling

Cancel the alarm with the EOR command after correcting

the fault as presented in INSTRUCTIONS.

1056 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1057: Alarm

4897966 FAULT IN DBUS INTERFACE OFREMOTE TUNE COMBINER

Meaning

The RTC automatically executes some self-tests in order to ensure

proper operation. A failure has been detected in the tests of the

RTC/D-bus. The BCF unit is not able to control the operation of

the RTC, and tuning of the RTC is impossible.

RTC

The remotely tunable combiner unit (RTC) combines several

transmitters to one single transmitting antenna. The RTC enables

lower signal losses compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1057 (1095)

7966 FAULT IN DBUS INTERFACE OF REMOTE TUNECOMBINER

Page 1058: Alarm

Cancelling

Cancel the alarm with the EOR command after correcting

the fault as presented in INSTRUCTIONS.

1058 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1059: Alarm

4907967 FAULT IN MEMORY OF REMOTETUNE COMBINER

Meaning

The RTC automatically executes some self-tests in order to ensure

proper operation. A failure has been detected in the tests of the

RTC's memory.

The RTC unit is not able to operate, and calls are not available via

this RTC.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1059 (1095)

7967 FAULT IN MEMORY OF REMOTE TUNE COMBINER

Page 1060: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1060 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1061: Alarm

4917968 CONTROLLER FAULTY IN REMOTETUNE COMBINER

Meaning

The RTC automatically executes some self-tests in order to ensure

proper operation. A failure has been detected in the self-tests of

the RTC. The unit is still able to operate via the redundant

DA converter. If both of the DA converters are broken, the RTC sends

the fatal alarm 7956.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1061 (1095)

7968 CONTROLLER FAULTY IN REMOTE TUNE COMBINER

Page 1062: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1062 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1063: Alarm

4927969 FORWARD POWER TOO LOW ATTX ANTENNA

Meaning

The RTC automatically executes some self-tests to ensure proper

operation. A failure has been detected in the self-tests of the RTC.

There is no transmission power at the TX antenna connection. There

should always be power at this point if the BCCH transmission is

activated. Missing power indicates a failure at the BCCH transmission.

RTC

The remotely tunable combiner unit (RTC) combines several transmitters

to one single transmitting antenna. The RTC enables lower signal losses

compared to the non-tunable antenna filter.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the operation of the transmitter and see that the cabling

is done properly. If the transmitter and cables are in order and the

BCCH transmission is activated then replace the RTC.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1063 (1095)

7969 FORWARD POWER TOO LOW AT TX ANTENNA

Page 1064: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1064 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1065: Alarm

4937970 FAULT IN MAIN BRANCH LNA OFRECEIVER MULTICOUPLER

Meaning

One of the parallel amplifiers is broken in the low noise amplifier

(LNA) of the main receiving path in the RMU. The RX performance is

degraded in the whole BTS sector. The BTS RF receiving capability

is reduced.

RMU

The receiver multicoupler unit (RMU) filters and amplifies the signal

received from the antenna. Four amplified output signals are connected

to the base station receivers. Additionally, there is one output to the

RMX (receiver multicoupler extension unit) that is used in large

configurations (more than 4 TRX in one cell). All outputs are doubled

for diversity purposes.

Each RMU contains two low noise amplifiers (LNA), one for the main

and one for diversity receiving path. One LNA contains two parallel

amplifier branches. The LNA is out of order if both of those amplifier

branches are faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1065 (1095)

7970 FAULT IN MAIN BRANCH LNA OF RECEIVERMULTICOUPLER

Page 1066: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1066 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1067: Alarm

4947971 FAULT IN DIVERSITY BRANCH LNAOF RECEIVER MULTICOUPLER

Meaning

One of the parallel amplifiers is broken in the low noise amplifier

(LNA) of the diversity receiving path in the RMU. The RX performance

is degraded in the whole BTS sector. The BTS RF receiving capability

is reduced.

RMU

The receiver multicoupler unit (RMU) filters and amplifies the signal

received from the antenna. Four amplified output signals are connected

to the base station receivers. Additionally, there is one output to the

RMX (receiver multicoupler extension unit) that is used in large

configurations (more than 4 TRX in one cell). All outputs are doubled

for diversity purposes.

Each RMU contains two low noise amplifiers (LNA), one for the main

and one for diversity receiving path. One LNA contains two parallel

amplifier branches. The LNA is out of order if both of those amplifier

branches are faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1067 (1095)

7971 FAULT IN DIVERSITY BRANCH LNA OF RECEIVERMULTICOUPLER

Page 1068: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1068 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1069: Alarm

4957972 MAIN BRANCH LNA OUT OFORDER IN RECEIVER MULTICOUPLER

Meaning

Both of the parallel amplifiers are broken in the low noise amplifier

(LNA) of the main receiving path in the RMU. The main RX does not work

in the whole BTS sector.

RMU

The receiver multicoupler unit (RMU) filters and amplifies the signal

received from the antenna. Four amplified output signals are connected

to the base station receivers. Additionally, there is one output to the

RMX (receiver multicoupler extension unit) that is used in large

configurations (more than 4 TRX in one cell). All outputs are doubled

for diversity purposes.

Each RMU contains two low noise amplifiers (LNA), one for the main

and one for diversity receiving path. One LNA contains two parallel

amplifier branches. The LNA is out of order if both of those amplifier

branches are faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1069 (1095)

7972 MAIN BRANCH LNA OUT OF ORDER IN RECEIVERMULTICOUPLER

Page 1070: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1070 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1071: Alarm

4967973 DIVERSITY BRANCH LNA OUT OFORDER IN RECEIVER MULTICOUPLER

Meaning

Both of the parallel amplifiers are broken in the low noise amplifier

(LNA) of the diversity receiving path in the RMU. The diversity RX

does not work in the whole BTS sector.

RMU

The receiver multicoupler unit (RMU) filters and amplifies the signal

received from the antenna. Four amplified output signals are connected

to the base station receivers. Additionally, there is one output to the

RMX (receiver multicoupler extension unit) that is used in large

configurations (more than 4 TRX in one cell). All outputs are doubled

for diversity purposes.

Each RMU contains two low noise amplifiers (LNA), one for the main

and one for diversity receiving path. One LNA contains two parallel

amplifier branches. The LNA is out of order if both of those amplifier

branches are faulty.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1071 (1095)

7973 DIVERSITY BRANCH LNA OUT OF ORDER IN RECEIVERMULTICOUPLER

Page 1072: Alarm

Instructions

Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1072 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1073: Alarm

4977974 BOOSTER TEMPERATURE TOOHIGH

Meaning

The temperature of the booster unit is too high.

Booster

The basic principle in the booster configuration is to locate a high

power amplifier in the BTS to boost downlink transmission.

In practice, the booster will replace the 2nd TRX in the BTS cabinet.

The booster configurations can be used with existing Nokia Talk-family

base stations in GSM 900, GSM 1800 and GSM 1900 networks in all cases

where cable loss compensation is needed.

When the alarm is activated, the BTS stops the TX transmission

of the TRX connected to the booster until the fault has been

corrected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see instructions on Alarm Structure

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1073 (1095)

7974 BOOSTER TEMPERATURE TOO HIGH

Page 1074: Alarm

Instructions

The booster starts functioning normally when the temperature has gone

down. Check the cabinet fans and the air conditioning at the cell site.

If the temperature of the booster is normal and this alarm is still

on, replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1074 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1075: Alarm

4987975 BOOSTER TX CONNECTIONFAULTY

Meaning

The SWR level in the booster is too high. The cabling or the combiner

is faulty.

Booster

The basic principle in the booster configuration is to locate a high

power amplifier in the BTS to boost downlink transmission.

In practice, the booster will replace the 2nd TRX in the BTS cabinet.

The booster configurations can be used with existing Nokia Talk-family

base stations in GSM 900, GSM 1800 and GSM 1900 networks in all cases

where cable loss compensation is needed.

When the alarm is activated, the BTS stops the TX transmission

of the TRX connected to the booster until the fault has been

corrected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see instructions on Alarm Structure

Instructions

The alarm requires no actions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1075 (1095)

7975 BOOSTER TX CONNECTION FAULTY

Page 1076: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

1076 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1077: Alarm

4997976 BOOSTER GAIN LEVEL TOO LOW

Meaning

The gain level in the booster is too low.

Booster

The basic principle in the booster configuration is to locate a high

power amplifier in the BTS to boost downlink transmission.

In practice, the booster will replace the 2nd TRX in the BTS cabinet.

The booster configurations can be used with existing Nokia Talk-family

base stations in GSM 900, GSM 1800 and GSM 1900 networks in all cases

where cable loss compensation is needed.

When the alarm is activated, the BTS stops the TX transmission

of the TRX connected to the booster until the fault has been

corrected.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

For more information, see instructions on Alarm Structure

Instructions

The alarm requires no actions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1077 (1095)

7976 BOOSTER GAIN LEVEL TOO LOW

Page 1078: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault situation is over.

1078 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1079: Alarm

5007980 NO CONNECTION TO SITE TESTMONITOR UNIT

Meaning

The site test monitor unit does not response to the poll command

from the BCFA unit on the D-Bus. Connection to the STM is broken or

the unit is not inserted.

A fatal failure in the STM does not affect the normal operation of the

BTS site. This alarm affects the tests of the BTS.

The site test monitor unit (STM) enables radio interface testing

of the BTS. It has many functions similar to an ordinary mobile phone.

Additionally, there are measurement functions for the BTS radio

interface.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

The unit which does not respond can be detected by examining

the alarm's diagnostic info field. If the diagnostic info field

points to equipment which is not installed to the BTS, check

the contents of the HW database. If the diagnostic info points

to equipment which is installed to the BTS, change the unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1079 (1095)

7980 NO CONNECTION TO SITE TEST MONITOR UNIT

Page 1080: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1080 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1081: Alarm

5017981 NO CONNECTION TO RADIORELAY

Meaning

The radio relay unit (RR) or some other transmission equipment(TE)

does not response to the poll command from the BCFA unit on the Q1 bus.

The connection to the RR/TE is broken or the unit is not inserted.

This alarm can affect the provided service of the BTS or transmission

network. The current status of the tranmission unit is not known and

obviously the commands to the RR do not reach unit.

RR

The radio relay (RR) is an 18 - 38 GHz micro wave radio unit. RR units

are used, as a part of the transmission network, to carry GSM speech,

data, and signalling in transmission network between BTS and BSC

network elements.

TE

The transmission equipment is a unspecified transmission device

which is connected to the base station via Q1 bus.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1081 (1095)

7981 NO CONNECTION TO RADIO RELAY

Page 1082: Alarm

Instructions

The unit which does not respond can be detected by examining

the alarm's diagnostic info field. If the diagnostic info field

points to equipment which is not installed to the BTS, check

the contents of the HW database. If the diagnostic info points

to equipment which is installed to the BTS, change the unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1082 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1083: Alarm

5027990 MAINS BREAKDOWN WITHOUTBATTERY BACK-UP

Meaning

The power supply unit or the common supply unit has lost its mains power

(or the overvoltage protection or the heat protection is activated).

Power Supply Unit

The power supply unit is the source of all voltages required in the

BTS units.

Common Supply Unit

The common supply unit is a power supply unit for the common units of

the base station. The sommon supply unit can be duplicated so that

the common units are unaffected by single power supply failure.

The power supply unit number 1 can be replaced by the common supply

units (one or two common supply units).

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1083 (1095)

7990 MAINS BREAKDOWN WITHOUT BATTERY BACK-UP

Page 1084: Alarm

Instructions

Check the mains voltage. If the mains voltage is in order, replace

the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

Exception:

If this alarm is reported from the common supply unit 1, cancelling

is not reported. Reset the site with a command after replacing the

common supply unit.

1084 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1085: Alarm

5037991 POWER SUPPLY FAULT

Meaning

There has been a failure in the output power from the PSUx.

This could be due to no mains power.

Power Supply Unit:

The power supply unit is the source of all voltages required

in the BTS units.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the mains power. If it is in order, replace the faulty

unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm

automatically when the fault has been corrected.

Exception:

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1085 (1095)

7991 POWER SUPPLY FAULT

Page 1086: Alarm

If this alarm is reported from the common supply unit 1 then

the cancel is not reported. Reset the site with a command after

replacing the common supply unit.

1086 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1087: Alarm

5047995 MAINS BREAKDOWN WITHBATTERY BACK-UP

Meaning

The mains power is lost in a site equipped with a battery backup

(or the overvoltage protection or the heat protection is activated).

Battery Back Up unit

The battery backup unit loads accumulators and controls the voltage

supply when the mains power is not available.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the mains supply.

If the mains supply is OK, check the EAC/Q1 cabling between the BTS

and IBBU/SISU. Repair the SISU/IBBU.

Flexi EDGE:

Description: One or more AC phases of the mains supply are faulty

and site is operating on battery backup.

Instructions:

1. Check the mains supply coming to the site support equipment.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1087 (1095)

7995 MAINS BREAKDOWN WITH BATTERY BACK-UP

Page 1088: Alarm

2. If the mains supply is ok, Check the EAC cabling between

ESMA and the site support equipment.

3. Repair the site support equipment.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1088 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1089: Alarm

5057996 BACK-UP BATTERY VOLTAGELOW

Meaning

The backup battery is almost empty. The voltage of the battery

is below the specified alarm limit.

Battery Back Up Unit

The battery backup unit loads accumulators and controls the voltage

supply when the mains power is not available.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the mains voltage. If the mains voltage is in order, check

the operation of the battery back up. Replace the faulty unit.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1089 (1095)

7996 BACK-UP BATTERY VOLTAGE LOW

Page 1090: Alarm

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

1090 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1091: Alarm

5067997 BATTERY CHARGER FAILURE

Meaning

The battery back up unit fails to charge the battery. Note that if

all chargers alarm simultaneously, a fuse has probably burnt or

the battery back up discharging protection is activated.

Battery Back Up Unit

The battery backup unit loads accumulators and controls the voltage

supply when the mains power is not available.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the mains voltage. If the mains voltage is in order, check

the operation of the battery back up. Replace the faulty unit.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1091 (1095)

7997 BATTERY CHARGER FAILURE

Page 1092: Alarm

1092 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1093: Alarm

5077998 BBUE INVERTER OVERLOAD

Meaning

During a mains breakdown or during a battery backup test

the inverter has been overloaded. If the mains power is missing

the BBUE can not supply power to the BTS. In case of battery backup

test the test is interrupted.

Battery Back Up Unit

The battery backup unit loads accumulators and controls the voltage

supply when the mains power is not available.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Check the load of the BBUE and reduce load.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1093 (1095)

7998 BBUE INVERTER OVERLOAD

Page 1094: Alarm

1094 (1095) # Nokia Siemens Networks DN9813099Issue 22-0 en

07/03/2008

Base Station Alarms (7000-7999)

Page 1095: Alarm

5087999 BATTERY FAILURE

Meaning

The output voltage of the battery module is too low during a battery test.

The battery test is done once a month by the BBUE unit.

Battery Back Up Unit

The battery backup unit loads accumulators and controls the voltage

supply when the mains power is not available.

Supplementary information fields

1-6 XX XX XX XX XX XX

1 2 3 4 5 6

1) rack (cabinet) number 4) type of unit

2) shelf number 5) unit number

3) slot 6) subunit number

See alarm instructions.

Instructions

Replace the battery.

Cancelling

Do not cancel the alarm. The system cancels the alarm automatically

when the fault has been corrected.

DN9813099Issue 22-0 en07/03/2008

# Nokia Siemens Networks 1095 (1095)

7999 BATTERY FAILURE