Slide 1Advance
When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature indicator bars as shown above
In order to reset the display, depress the “ACTIVATE CONTROLS” or “ALARM OFF” pad above.
Select a program below
Thermistor Alarm
Service Mode
Sabbath Mode
Forced Defrost
In order to adjust the temperature settings you must first activate the control panel
Using the cursor, depress the “Activate Controls” pad above
With the panel active you can see what the settings are adjusted to. In this example the unit is set to 5 bars, which is the default setting from the factory.
In order to adjust the settings you must depress the FRZ TEMP button
Using the cursor, depress the “FRZ TEMP” pad above
The unit is set at approximately 15°F. 1 Bars are illuminated.
This is the minimum setting –warmest temperature
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 13°F. 2 Bars are illuminated.
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 11°F. 3 Bars are illuminated.
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 10°F. 4 Bars are illuminated.
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 09°F. 5 Bars are illuminated.
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 08°F. 6 Bars are illuminated.
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 07°F. 7 Bars are illuminated.
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 05°F. 8 Bars are illuminated.
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
The unit is set at approximately 03°F. 9 Bars are illuminated.
This is the maximum setting – coldest temperature
Using the cursor, depress the “HIGHER TEMP” to raise the temperature or “LOWER TEMP” to lower the temp.
Main page
Showroom mode allows electronic controls and interior lights to function independently of the refrigeration system
To place the unit into Showroom mode, press the “Activate Controls” pad to activate the panel.
Using the cursor, depress “Activate Controls” from the panel above.
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
HIGHER TEMP
ALARM OFF
Continue
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
HIGHER TEMP
ALARM OFF
After 3 seconds you will hear 3 “Beeps” and the Blue LED shown above (3rd from right) will illuminate
After 3 seconds you will hear 3 “Beeps” and the Blue LED shown above (3rd from right) will illuminate
You have now engaged “Showroom Mode”
To exit the Showroom mode, depress the “Exit Showroom Button” below or to exit, depress “Main Page.
Exit Showroom mode
Main page
To exit the Display Mode you must first activate the control panel.
Depress the “ACTIVATE CONTROLS” pad above
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
HIGHER TEMP
ALARM OFF
Continue
Continue
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
HIGHER TEMP
ALARM OFF
After 3 seconds you will hear 3 “Beeps” and the Blue LED shown above will extinguish
After 3 seconds you will hear 3 “Beeps” and the Blue LED shown above will extinguish
You have now disengaged “Showroom Mode”
To enter the Showroom mode, depress the “Enter Showroom Button” below or to exit, depress “Main Page.
Enter Showroom mode
Main page
Sabbath mode is used to disable interior lights and alarms for observance of the Sabbath
To place the unit into Sabbath mode, press the “Activate Controls” pad to activate the panel.
Using the cursor, depress “Activate Controls” from the panel above.
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
DISPLAY OFF
Continue
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
DISPLAY OFF
After 3 seconds you will hear 3 “Beeps” to indicate you have entered Sabbath Mode.
All 3 Blue LED’s shown above will illuminate to indicate Sabbath Mode.
Disable Sabbath Mode
Main page
To disable the Sabbath Mode you must first activate the control panel.
Depress the “ACTIVATE CONTROLS” pad above
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
DISPLAY OFF
Continue
With the panel activated, simultaneously press and HOLD the following pads for 3 seconds:
ACTIVATE CONTROLS
DISPLAY OFF
After 3 seconds you will hear 3 “Beeps” to indicate you have disabled Sabbath Mode.
The display will return to normal operation
Enable Sabbath Mode
Main page
Max Freezer mode adjusts the freezer temperature to the coldest setting for 24 hours, at the end of which, the freezer temperature automatically returns to its previous setting
In order to activate, depress the “Activate Controls” above
With the panel active you can see what the settings are adjusted to. In this example the unit is set to 5 bars, which is the default setting from the factory.
Using the cursor, depress the “MAX FRZ” pad above
Main page
Main page
Max Freezer has been activated. All 9 bars are illuminated. The Blue indicator marked “MAX FRZ” is also activated in the display. In order to deactivate press the “MAX FRZ” pad again. When the indicator has extinguished you have returned to the normal cooling mode.
The High temperature alarm sounds and the High Temp indicator (Red) will show in the display if the freezer temperature is greater than 15° Fahrenheit (-9.5 °C) for two hours.
The FRZ TEMP indicator will flash on and off. The alarm will end when the temperature is brought back to a proper setting.
To deactivate the high temperature alarm, press the “Alarm OFF” pad
Main page
The Door Open alarm sounds and an indicator (Red) LED will blink in the display if the door is left open for three minutes or more. The delay time can be changed in Service Mode B.
To deactivate the door open alarm, press the “ALARM OFF” pad. Closing the door will also shut the alarm off.
Main page
Service Mode
To enter service modes A and B you will need to press a series of pads in a programmed sequence. This sequence includes hidden pads (Shown above as dotted white lines)
The pad on the left of the display is the “Hidden Button” while the pad on the right is the “MAX REF” button. Because this is an all freezer model the “MAX REF” button is not indicated on the panel though it is still present.
Continue
Hidden
Button
Within 6 seconds press the following sequence:
ACTIVATE CONTROLS --- HIDDEN BUTTON --- MAX REF --- MAX FRZ --- MAX REF --- MAX FRZ
Using the cursor, enter the code shown on the pads above. For a demonstration depress the Demo button below.
Demo
Hidden
Button
Within 6 seconds press the following sequence:
ACTIVATE CONTROLS --- HIDDEN BUTTON --- MAX REF --- MAX FRZ --- MAX REF --- MAX FRZ
Demonstration
Hidden
Button
Within 6 seconds press the following sequence:
ACTIVATE CONTROLS --- HIDDEN BUTTON --- MAX REF --- MAX FRZ --- MAX REF --- MAX FRZ
Demonstration
Hidden
Button
Within 6 seconds press the following sequence:
ACTIVATE CONTROLS --- HIDDEN BUTTON --- MAX REF --- MAX FRZ --- MAX REF --- MAX FRZ
Demonstration
Hidden
Button
Within 6 seconds press the following sequence:
ACTIVATE CONTROLS --- HIDDEN BUTTON --- MAX REF --- MAX FRZ --- MAX REF --- MAX FRZ
Demonstration
Hidden
Button
Within 6 seconds press the following sequence:
ACTIVATE CONTROLS --- HIDDEN BUTTON --- MAX REF --- MAX FRZ --- MAX REF --- MAX FRZ
Demonstration
Hidden
Button
MAX REF
When you have entered the Service Mode you begin in MODE A, which is indicated by the red LED to the right of the High Temp LED as shown above.
In Mode A you can read the thermistor temperature by the use of a binary coded decimal format. Mode A is also where you select intervals of defrost when the unit is set to conventional defrost (Assigned in MODE B)
Mode B is used for all other programmable modes. To understand how the thermistor is read, depress the Thermistor Demo button below.
To advance to SERVICE MODE B, depress the “ACTIVATE CONTROLS” pad above or select Thermistor Demo below
NOTE: Pressing and holding the ACTIVATE CONTROLS” pad for 3 seconds at any time will take you out of Service Mode!
Thermistor Demo
The code utilizes the first 8 temperature bars in the display shown above. Depending on the combination of lit LEDS you will be able to determine what the thermistor is reading in Fahrenheit. The 9th temperature bar will light is the temperature is a (-) minus temp.
Continue
The next 4 digits represent the 0’s column.
Beginning on the left side of the display, The first 4 digits represent the 10’s Column.
Add together all lit indicators 1 through 4 according to their value to obtain ten’s column digit
The first 4 bars have the following value:
1st bar = 8 2nd bar = 4 3rd bar = 2 4th bar = 1
In the example above, none of the first four bars are lit. This indicates that our temperature is less than 10°Farhrenheit
Continue
Add together all lit indicators 5 through 8 according to their value to obtain one’s column digit
The last 4 bars have the following value: 5th bar = 8 6th bar = 4 7th bar = 2 8th bar = 1
In the example above, the 5th Bar is lit (8) and the 8th bar is lit (1). Add these two numbers together: 8+1= 9. The thermistor is reading at 9°Farhrenheit
Repeat DEMO
You are in Service Mode A
To switch to Service Mode B depress the “ACTIVATE CONTROLS” pad above or hit continue below…
Thermistor Demo
You are now in Service Mode B.
In the display you will see the High Temp Indicator (RED) illuminated. This is the Service Mode B LED
In the display above there is also a Blue LED lit 2 spaces to the right of the Service Mode B LED. This indicates that the unit is programmed for adaptive defrost (Factory default). If it is not illuminated the unit is programmed for Manual defrost.
This will be covered later in the presentation
Depress the “ACTIVATE CONTROLS” pad to toggle back to Service Mode A or hit continue below…
Continue
Forced Defrost
By entering a keyed sequence on the control panel you can force the unit to advance into a defrost cycle. If the evaporator coil is iced or frosted over, or to simply check the defrost system
In order to advance to unit to a defrost cycle you must first depress the “ACTIVATE CONTROLS” pad above.
In Service Mode B the following functions can be adjusted:
Automatic Keyboard Functions
Door Alarm Delay
Forced Pull down
Select one of the programs above for a brief description and procedure instruction. Select “ACTIVATE CONTROLS” to toggle back to Service Mode A
Return to Main Menu
Simultaneously press and hold the “MAX FRZ” and the “DISPLAY OFF” pad for 3 seconds.
Simultaneously press and hold the “MAX FRZ” and the “DISPLAY OFF” pad for 3 seconds.
If the compressor was running it will shut off and the defrost heater should begin to heat as long as the defrost terminator is closed. This is a quick and easy test to see if the defrost terminator and heater are functioning properly.
Main page
Door Alarm Delay
The Door alarm delay can be adjusted to a set time as to when it will sound when the door is open. The default setting is 3 minutes which is represented by the temperature indicator bars.
In order to adjust the delay time depress the “ALARM OFF” pad above
Return to Service Mode
Door Alarm Delay
The Door alarm delay can be adjusted to a set time as to when it will sound when the door is open. The default setting is 3 minutes. The temperature bars represent 1 minute intervals and can be adjusted to a minimum of 1 minute up to a maximum of 9 minutes.
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the delay setting on the door alarm.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 1 minute (Minimum)
Using the “LOWER TEMP” button, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 2 minutes
Using the “LOWER TEMP” or “HIGHER TEMP” buttons, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 3 minutes
Using the “LOWER TEMP” or “HIGHER TEMP” buttons, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 4 minutes
Using the “LOWER TEMP” or “HIGHER TEMP” buttons, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 5 minutes
Using the “LOWER TEMP” or “HIGHER TEMP” buttons, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 6 minutes
Using the “LOWER TEMP” or “HIGHER TEMP” buttons, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 7 minutes
Using the “LOWER TEMP” or “HIGHER TEMP” buttons, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 8 minutes
Using the “LOWER TEMP” or “HIGHER TEMP” buttons, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Door Alarm Delay
The Door alarm is set to 9 minutes (Maximum)
Using the “HIGHER TEMP” button, adjust the delay setting on the door alarm.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run duration can be adjusted to a set time as to how long the unit will run at its lowest temperature.
The default setting is 10 hours. Minimum run time is 2 hours and maximum is 18 hours.
In order to adjust the Max Freeze Run Duration Time, depress the “MAX FRZ” pad above
Return to Service Mode
Max Freeze Run Time Duration
The Max Freeze run time can be adjusted as to how log the unit will run at its coldest setting. The default setting is the 5th bar or 10 hours or Max Freeze Run Time.
Each temperature bar represents 2 hour increments and can be adjusted to a minimum of 2 hours (1st bar) up to a maximum of 18 hours (9th bar).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the run time duration.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 1st bar (2 Hours).
Using the “LOWER TEMP” button, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 2nd bar (4 Hours).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 3rd bar (6 Hours).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 4th bar (8 Hours).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 5th bar (10 Hours).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 6th bar (12 Hours).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 7th bar (14 Hours).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 8th bar (16 Hours).
Using the “HIGHER TEMP” or “LOWER TEMP” buttons, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B
Max Freeze Run Time Duration
The Max Freeze Run Time is set to the 9th bar (18 Hours).
Using the “HIGHER TEMP” button, adjust the Max Freeze duration time.
Once the desired setting has been selected, press and hold the “ACTIVATE CONTROLS” pad for 3 seconds. You will hear 3 tones to confirm selection.
Depress “Activate Controls” to return to Service Mode B