OptiX OSN 7500 Intelligent Optical Switching System V100R009 Routine Maintenance Issue 01 Date 2009-08-14 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
66
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

OptiX OSN 7500 Intelligent Optical Switching System

V100R009

Routine Maintenance

Issue 01

Date 2009-08-14

Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Page 2: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For anyassistance, please contact our local office or company headquarters.

Huawei Technologies Co., Ltd.Address: Huawei Industrial Base

Bantian, LonggangShenzhen 518129People's Republic of China

Website: http://www.huawei.com

Email: [email protected]

Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent of Huawei Technologies Co., Ltd. Trademarks and Permissions

and other Huawei trademarks are the property of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders. NoticeThe information in this document is subject to change without notice. Every effort has been made in thepreparation of this document to ensure accuracy of the contents, but the statements, information, andrecommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Page 3: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Contents

About This Document.....................................................................................................................1

1 Overview of Routine Maintenance.........................................................................................1-11.1 Safety Operation Guide...................................................................................................................................1-2

1.1.1 Safety Labels..........................................................................................................................................1-21.1.2 Using Fibers with Safety........................................................................................................................1-31.1.3 ESD........................................................................................................................................................1-51.1.4 Laser.......................................................................................................................................................1-61.1.5 Short Circuit...........................................................................................................................................1-81.1.6 Operations on the Equipment with Power On........................................................................................1-81.1.7 Precautions of Using the T2000.............................................................................................................1-8

1.2 Purpose of Routine Maintenance..................................................................................................................1-101.3 Routine Maintenance Items and Periods.......................................................................................................1-101.4 Tools Required for Routine Maintenance.....................................................................................................1-11

2 Guide for Routine Maintenance in the Center and Record Table...................................2-12.1 Checking the Status of the NE and Boards.....................................................................................................2-32.2 Browsing Network-Wide Alarms....................................................................................................................2-42.3 Browsing Abnormal Events............................................................................................................................2-62.4 Browsing the Current Performance Events.....................................................................................................2-7

2.4.1 Browsing the Current SDH Performance Events...................................................................................2-82.4.2 Browsing the Current Performance Events at the Ethernet Port............................................................2-92.4.3 Browsing the Current Performance Events at the ATM Port...............................................................2-102.4.4 Browsing the Current VPI&VCI Performance Events at the ATM Port.............................................2-11

2.5 Browsing the History Performance Events...................................................................................................2-132.5.1 Browsing the History SDH Performance Events.................................................................................2-132.5.2 Browsing the History Performance Events at the Ethernet Port..........................................................2-152.5.3 Browsing the History Performance Events at the ATM Port...............................................................2-162.5.4 Browsing the History VPI&VCI Performance Events at the ATM Port.............................................2-17

2.6 Viewing the Timeslot Allocation Diagram...................................................................................................2-192.7 Querying Board Version Information...........................................................................................................2-202.8 Checking the Optical Power..........................................................................................................................2-212.9 Checking the Temperature............................................................................................................................2-222.10 Verifying the MSP Switching.....................................................................................................................2-23

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance Contents

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

i

Page 4: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

2.11 Backing up the Database of the T2000.......................................................................................................2-242.12 Backing up Data of the ASON NE..............................................................................................................2-262.13 Maintenance Record Table..........................................................................................................................2-27

3 Guide for On-Site Routine Maintenance and Record Table.............................................3-13.1 Cleaning the Air Filter.....................................................................................................................................3-23.2 Maintenance Record Table..............................................................................................................................3-3

4 Guide for Routine Maintenance of the Spare Parts and Record Table...........................4-14.1 Testing the Spare Parts....................................................................................................................................4-24.2 Maintenance Record Table..............................................................................................................................4-3

A Glossary.....................................................................................................................................A-1

B Acronyms and Abbreviations.................................................................................................B-1

ContentsOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

ii Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 5: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Figures

Figure 1-1 Slanting optical interface....................................................................................................................1-4Figure 1-2 Level optical interface........................................................................................................................1-5Figure 1-3 Wearing an ESD wrist strap (OptiX OSN 7500)................................................................................1-6Figure 3-1 Position of the air filter in the OptiX OSN 7500 subrack..................................................................3-3

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance Figures

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

iii

Page 6: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf
Page 7: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Tables

Table 1-1 Safety labels stuck on the equipment...................................................................................................1-2Table 1-2 Maintenance items and periods..........................................................................................................1-10Table 1-3 Tools required for the routine maintenance.......................................................................................1-11Table 2-1 Criteria for the check of bit error and pointer justification..................................................................2-8Table 2-2 Operation criteria for the current performance events at the ATM port............................................2-11Table 2-3 Operation criteria for the current VPI&VCI performance events at the ATM port...........................2-12Table 2-4 Main SDH history performance events and the check criteria...........................................................2-14Table 2-5 Operation criteria for the history performance events at the ATM port............................................2-17Table 2-6 Operation criteria for the history VPI&VCI performance events at the ATM port...........................2-18Table 2-7 Requirements on the environment where the board runs...................................................................2-22Table 2-8 Operation criteria for the MSP switching..........................................................................................2-24

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance Tables

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

v

Page 8: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf
Page 9: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

About This Document

PurposeThis document describes each routine maintenance item for the OptiX OSN equipment in thefollowing terms:

l Maintenance purpose

l Maintenance period

l Maintenance standard

l Maintenance procedure

This document provides guidelines on the routine maintenance of the OptiX OSN equipment.

Related VersionsThe following table lists the product versions related to this document.

Product Name Version

OptiX OSN 7500 V100R009

OptiX iManager T2000 V200R008C00

Intended AudienceThis document is intended for:

l On-site maintenance engineer

l Network monitoring engineer

l System maintenance engineer

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance About This Document

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1

Page 10: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

OrganizationThis document is organized as follows.

Chapter Description

1 Overview of RoutineMaintenance

Describes the precautions, purpose, items, and tools requiredfor the routine maintenance.

2 Guide for RoutineMaintenance in the Centerand Record Table

Describes the operation procedure for each maintenance itemin the NM center.

3 Guide for On-SiteRoutine Maintenance andRecord Table

Describes how to clean the air filter on site.

4 Guide for RoutineMaintenance of the SpareParts and Record Table

Describes how to test spare parts.

A Glossary Lists the terms in the document.

B Acronyms andAbbreviations

Lists the acronyms and abbreviations in the document.

Conventions

Symbol ConventionsThe symbols that may be found in this document are defined as follows.

Symbol Description

DANGERIndicates a hazard with a high level of risk, which if notavoided, will result in death or serious injury.

WARNINGIndicates a hazard with a medium or low level of risk, whichif not avoided, could result in minor or moderate injury.

CAUTIONIndicates a potentially hazardous situation, which if notavoided, could result in equipment damage, data loss,performance degradation, or unexpected results.

TIP Indicates a tip that may help you solve a problem or savetime.

NOTE Provides additional information to emphasize orsupplement important points of the main text.

About This DocumentOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

2 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 11: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

General Conventions

The general conventions that may be found in this document are defined as follows.

Convention Description

Times New Roman Normal paragraphs are in Times New Roman.

Boldface Names of files, directories, folders, and users are in boldface. Forexample, log in as user root.

Italic Book titles are in italics.

Courier New Examples of information displayed on the screen are in Courier New.

Command Conventions

The command conventions that may be found in this document are defined as follows.

Convention Description

Boldface The keywords of a command line are in boldface.

Italic Command arguments are in italics.

[ ] Items (keywords or arguments) in square brackets [ ] are optional.

{ x | y | ... } Optional items are grouped in braces and separated by vertical bars.One item is selected.

[ x | y | ... ] Optional items are grouped in brackets and separated by vertical bars.One item is selected or no item is selected.

{ x | y | ... } * Optional items are grouped in braces and separated by vertical bars.A minimum of one item or a maximum of all items can be selected.

[ x | y | ... ]* Optional items are grouped in brackets and separated by vertical bars.Several items or no item can be selected.

GUI Conventions

The GUI conventions that may be found in this document are defined as follows.

Convention Description

Boldface Buttons, menus, parameters, tabs, windows, and dialog titles are inboldface. For example, click OK.

> Multi-level menus are in boldface and separated by the ">" signs. Forexample, choose File > Create > Folder .

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance About This Document

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

3

Page 12: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Keyboard OperationThe keyboard operations that may be found in this document are defined as follows.

Format Description

Key Press the key. For example, press Enter and press Tab.

Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt+A meansthe three keys should be pressed concurrently.

Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means the two keysshould be pressed in turn.

Mouse OperationsThe mouse operations that may be found in this document are defined as follows.

Action Description

Click Select and release the primary mouse button without moving the pointer.

Double-click Press the primary mouse button twice continuously and quickly withoutmoving the pointer.

Drag Press and hold the primary mouse button and move the pointer to a certainposition.

Update HistoryUpdates between document issues are cumulative. Therefore, the latest document issue containsall updates made in previous issues.

Updates in Issue 01 (2009-08-14) Based on Product Version V100R009This document is the first release of version V100R009.

About This DocumentOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

4 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 13: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

1 Overview of Routine Maintenance

About This Chapter

This topic describes the precautions, purpose, items and required tools for the routinemaintenance.

1.1 Safety Operation GuideThis section provides guidelines to safety operations during routine maintenance. The guidelinesconsist of the safety regulations for humans and the equipment. These guidelines must befollowed to avoid injuries to humans or damage to equipment.

1.2 Purpose of Routine MaintenanceThis section describes the purpose of routine maintenance.

1.3 Routine Maintenance Items and PeriodsThis section provides a detailed description of the maintenance items and maintenance periodsaccording to different maintenance owners and maintenance sites.

1.4 Tools Required for Routine MaintenanceThis section describes tools required for routine maintenance.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 1 Overview of Routine Maintenance

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1-1

Page 14: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

1.1 Safety Operation GuideThis section provides guidelines to safety operations during routine maintenance. The guidelinesconsist of the safety regulations for humans and the equipment. These guidelines must befollowed to avoid injuries to humans or damage to equipment.

1.1.1 Safety LabelsDuring the equipment maintenance, observe the precautions indicated by the warnings and safetysymbols to prevent damage to the human body or equipment.

1.1.2 Using Fibers with SafetyUse the fiber in a safe and correct manner, to ensure the normal operation of the equipment andprevent damage to the human body and equipment.

1.1.3 ESDESD can damage boards. Some measures such as proper grounding and wearing the ESD wriststrap should be taken to protect the equipment against ESD.

1.1.4 LaserWhen you install and maintain equipment, follow the safety precautions to prevent personalinjury or equipment damage.

1.1.5 Short CircuitWhen you install and maintain equipment, follow the operation rules when you use or place atool to prevent the short circuit caused by metallic objects such as tools.

1.1.6 Operations on the Equipment with Power OnWhen you operate on the equipment when it is powered on, ensure that you take the safetyprecautions to prevent personal injury or equipment damage.

1.1.7 Precautions of Using the T2000To use the T2000 correctly, you should observe the precautions of running, setting, and operatingthe T2000.

1.1.1 Safety LabelsDuring the equipment maintenance, observe the precautions indicated by the warnings and safetysymbols to prevent damage to the human body or equipment.

Table 1-1 lists the safety labels stuck to the equipment.

Table 1-1 Safety labels stuck on the equipment

Label Description

ESD Protection SymbolIndicates a caution that you need to wearan ESD wrist strap or glove to avoiddamage caused by electrostatic to boards.

1 Overview of Routine MaintenanceOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

1-2 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 15: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Label Description

CLASS 1LASER

PRODUCT

LASERRADIATION

DO NOT VIEW DIRECTLYWITH OPTICALINSTRUMENTS

CLASS 1M LASERPRODUCT

Laser Level SymbolIndicates a warning that laser beam maycause injuries to eyes or skin.

Subrack Grounding LabelIndicates the position of the groundingpoint.

ATTENTION 警告

CLEAN PERIODICALLY定期清洗

Regular Cleaning LabelIndicates a warning that you need toregularly clean the air filter.

严禁在风扇高速旋转时接触叶片

DON'T TOUCH THEFAN LEAVES BEFORETHEY SLOW DOWN !

Fan Warning LabelIndicates a warning that you cannot touchthe fan blade before the fan stops.

! APDReceiver

MAX:-9dBm

APD Alarm LabelIndicates the optical interface overloadthreshold is -9 dBm.

1.1.2 Using Fibers with SafetyUse the fiber in a safe and correct manner, to ensure the normal operation of the equipment andprevent damage to the human body and equipment.

DANGERThe laser beam at the optical interface board or from the fiber may cause injuries to eyes. Donot stare into the optical interface or fiber connector during installation and maintenance ofoptical interface boards or fibers.

Clean the Fiber Connectors and Optical Interfaces

Use the special cleaning tools and materials to clean the fiber connectors and optical interfaces.Some common tools and materials are listed as follows.

l Special cleaning solvent (Isoamylol is preferred, propyl alcohol is the next, alcohol andformalin are forbidden.)

l Non-woven lens tissue

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 1 Overview of Routine Maintenance

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1-3

Page 16: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

l Special compressed gas

l Cotton stick (medical cotton or long fiber cotton)

l Special cleaning roll, used with cleaning solvent listed in the first item

l Magnifier for optical connectors

For details on how to check and clean fibers, refer to "Inspecting and Cleaning the Fiber-OpticalConnectors" in the Supporting Task.

Replace FibersUse filter caps to cap the connectors of the fibers that are not used temporarily.

Connect FibersWhen the optical power is too high, use an attenuator to prevent damage to the optical interface.

l The slanting optical interface can be directly connected to an attenuator, which must beinserted in the IN port, not in the OUT port.

l The level optical interface cannot be directly connected to an attenuator, but can beconnected through the optical distribution frame (ODF).

Figure 1-1 and Figure 1-2 respectively show the slanting and level optical interfaces.

Figure 1-1 Slanting optical interface

Slantingoptical

interface

1 Overview of Routine MaintenanceOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

1-4 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 17: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Figure 1-2 Level optical interface

Leveloptical

interface

1.1.3 ESDESD can damage boards. Some measures such as proper grounding and wearing the ESD wriststrap should be taken to protect the equipment against ESD.

The general rules pertaining to ESD are as follows:

l Check that the equipment is securely grounded according to requirements.

l Always wear an ESD wrist strap during the operation.

l Before touching a device, a board or an integrated circuit (IC) chip, you must wear an ESDwrist strap, and properly ground the other end of the ESD wrist strap to prevent staticelectricity in the human body from damaging the static sensitive components. Ensure thatthe metallic portion of the ESD wrist strap is in contact with the skin and the other end isproperly connected to the grounding connector. If the ESD wrist strap is not available, wearthe antistatic gloves. For the method of how to wear an ESD wrist strap, refer to Figure1-3, , , , and .

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 1 Overview of Routine Maintenance

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1-5

Page 18: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Figure 1-3 Wearing an ESD wrist strap (OptiX OSN 7500)

l Check the validity and functionality of the wrist strap. Its resistance value ranges from 0.75

Mohm to 10 Mohm. If the validity period (usually two years) of the wrist strap expires, orthe resistance value fails to meet requirements, replace the ESD wrist strap.

l Avoid touching boards with your clothing, because the touching generates static electricitybeyond the protection scope of the wrist strap.

l Wear an ESD wrist strap or antistatic gloves and place the board on an antistatic pad whenreplacing board software or chips. Use antistatic tweezers or extraction tools to replacechips. Do not touch chips, circuits, or pins with bare hands.

l Keep all the boards and components that are to be installed in shielding bags. Place removedboards and components on an antistatic pad or other antistatic materials. Do not use non-antistatic materials such as white foams, common plastic bags, or paper bags to pack boardsor allow them to touch boards.

l Wear an ESD wrist strap when operating the ports of boards because they are also ESD-sensitive. Discharge the static electricity of cables and protective sleeves before connectingthem to the ports.

l Reserve some packing materials (such as antistatic boxes and bags) for board in the roomfor future use.

1.1.4 LaserWhen you install and maintain equipment, follow the safety precautions to prevent personalinjury or equipment damage.

The safety precautions of lasers consists of the following two parts:

l Personal injury

1 Overview of Routine MaintenanceOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

1-6 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 19: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

l Equipment damage

Personal Injury

DANGERThe laser beams from fibers or the optical interface on boards cause eye damage. Do not lookdirectly at the optical interfaces or fiber connectors during the installation and maintenance ofboards or fibers.

DANGERIn the case of an optical interface that is in use, use protective caps to cover the optical interfaceand the fiber connector when you remove the fiber from the optical interface to prevent eyedamage.

Equipment Damage

CAUTIONUse protective caps to cover idle optical interfaces and fiber connectors so that they do not gatherdust.

CAUTIONWhen performing a hardware loopback test on optical interfaces by using a fiber, add the opticalattenuator to prevent damage to the equipment because of the high power of the laser beam. Addthe optical attenuator at the receive optical interface on the board that supports opticalattenuators.

CAUTIONWhen you use the optical time domain reflectometer (OTDR), disconnect the fiber between theopposite station and the board to prevent damage to the receive optical module because of highoptical power.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 1 Overview of Routine Maintenance

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1-7

Page 20: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

CAUTIONExercise caution when you remove or insert the board that is connected with fibers.

1.1.5 Short CircuitWhen you install and maintain equipment, follow the operation rules when you use or place atool to prevent the short circuit caused by metallic objects such as tools.

CAUTIONDo not place tools, such as screwdrivers, on the air baffle.

CAUTIONEnsure that screws do not fall off into the subrack or chassis.

1.1.6 Operations on the Equipment with Power OnWhen you operate on the equipment when it is powered on, ensure that you take the safetyprecautions to prevent personal injury or equipment damage.

DANGERDo not install or disassemble the equipment when it is powered on.

DANGERDo not install or remove the power cables of the equipment when it is powered on.

1.1.7 Precautions of Using the T2000To use the T2000 correctly, you should observe the precautions of running, setting, and operatingthe T2000.

Precautions of Running the T2000To ensure that the T2000 runs properly, be aware of the following precautions:l To ensure that the working power of the T2000 computer is stable, use the uninterrupted

power supply (UPS).

1 Overview of Routine MaintenanceOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

1-8 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 21: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

l Install the T2000 software in the file path that contains only English characters.

l A T2000 license file is an authorized file and must be kept properly. Do not make anychange to the license file. Otherwise, the license becomes invalid.

l On the UNIX platform, log in to the operating system on which the T2000 server is installedas user t2000.

l On the Windows platform, log in to the operating system as the user that is used during theT2000 installation. Do not change the login user of Windows.

Precautions of Setting the T2000 Computer

When you set the computer where the T2000 server or client resides, be aware of the followingprecautions:

l Do not modify the system time when the T2000 is running. Set the system time when youinstall the T2000.

– If the system time of the server need be modified, log out of the T2000 server and thenmodify the system time. After the modification, restart the T2000 server.

– If the system time of the client need be modified, log out of the T2000 client and thenmodify the system time. After the modification, restart the T2000 client.

l Do not modify the name and IP address of the computer where the T2000 server is installed,unless required. Otherwise, the communication between the T2000 server and the NE mayfail.

Precautions of Operating the T2000

When you operate the T2000, be aware of the following precautions:

l When the T2000 is running, ensure that the data on the T2000 is consistent with the dataon the NE.

– When the data configuration on an NE is complete and the NE runs properly, use theupload or synchronization function to keep the data consistency between the T2000 andthe NE.

– When the NE data stored on the NE is incorrect and the NE data stored on the T2000is correct, use the download or restoration function to keep the data consistency betweenthe T2000 and the NE.

l To change the configuration data, observe the following rules:

– Before you change the configuration data, upload the NE data to keep the NE dataconsistency between the T2000 and the NE.

– Before you change the configuration data, back up the NE database and the T2000database, so that the data can be restored in the case of an operation failure.

– After you change the configuration data, back up the NE database and the T2000database, so that the data can be restored in the case of an NE anomaly.

l Before you set parameters, query the latest data from the NE.

l Exercise caution when you perform a risky operation. Usually, on the T2000, a prompt isdisplayed indicating the risk before a risky operation is performed.

l Periodically back up the MO data to minimize the loss caused by system anomalies.

– Back up the MO data of the T2000 monthly.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 1 Overview of Routine Maintenance

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1-9

Page 22: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

– When the service configuration data is changed, immediately back up the MO data ofthe T2000.

l Periodically clear outdated backup data to ensure that there is sufficient disk space for newbackup data.

l For a T2000 that is accessed by multiple clients, you are recommended to use only oneclient for configuration and the other clients for monitoring.

1.2 Purpose of Routine MaintenanceThis section describes the purpose of routine maintenance.

l Check the current state of the equipment to determine the working condition of theequipment and to locate a fault in time.

l Check the protection schemes of the equipment to make sure that services can be protectedin case of a fault.

l Clean the air filter of the equipment to keep the equipment in a good running state.

1.3 Routine Maintenance Items and PeriodsThis section provides a detailed description of the maintenance items and maintenance periodsaccording to different maintenance owners and maintenance sites.

Table 1-2 lists the maintenance items and periods.

Table 1-2 Maintenance items and periods

MaintenanceOwner

MaintenanceSite

Maintenance Item MaintenancePeriod

Networkadministrator

center Checking the status of the NE andboards

Daily

Browsing network-wide alarms Daily

Browsing abnormal events Daily

Browsing the current performanceevents

Daily

Browsing the history performanceevents

Daily

Viewing the timeslot allocationdiagram

Daily

Querying board versioninformation

Daily

Checking the optical power Daily

Checking the temperature Daily

Verifying the MSP switching Quarterly

1 Overview of Routine MaintenanceOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

1-10 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 23: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

MaintenanceOwner

MaintenanceSite

Maintenance Item MaintenancePeriod

Backing up the database of theT2000

Monthly

Backing up data of the ASON NE Every twoweeks

Fieldmaintenanceengineer

Equipment site Cleaning the air filter Every twomonths

Maintenanceengineer

Parts inventory Testing the spare parts Yearly

1.4 Tools Required for Routine MaintenanceThis section describes tools required for routine maintenance.

Table 1-3 lists the tools required for the maintenance.

Table 1-3 Tools required for the routine maintenance

Tools Usage

T2000 The T2000 is used for routine maintenance of the equipment, and databackup at both the NE and the T2000 sides.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 1 Overview of Routine Maintenance

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

1-11

Page 24: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf
Page 25: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

2 Guide for Routine Maintenance in theCenter and Record Table

About This Chapter

This topic describes the operation procedures for each maintenance item at the center.

2.1 Checking the Status of the NE and BoardsRegularly check the status of the NE and boards on the NE. In this way, the anomalies can bedetected and then handled in time.

2.2 Browsing Network-Wide AlarmsRegularly browse alarms to detect and rectify faults in time.

2.3 Browsing Abnormal EventsRegularly browse the performance events of an NE to check the running status of the equipment.In this case, possible hazards can be prevented in time.

2.4 Browsing the Current Performance EventsBrowse the current performance events to check the current running state of the equipment.Hence, the latent hazards can be cleared in time.

2.5 Browsing the History Performance EventsBrowse the history performance events to check the long-term running state of the equipment.Hence, the latent hazards can be cleared in time.

2.6 Viewing the Timeslot Allocation DiagramTo check the timeslots used for the protection subnet and to ensure normal allocation, view thetimeslot allocation diagram.

2.7 Querying Board Version InformationYou can query the board version mapping information in the board information report and boardmanufacturing information report.

2.8 Checking the Optical PowerIf the mean launched optical power and the received optical power at the optical interface areexcessively high or low, the services are affected due to bit errors or damage to the opticalcomponents. To prevent this, you need to check the optical power periodically.

2.9 Checking the Temperature

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-1

Page 26: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Maintain the environment of the equipment room in a periodic manner to ensure that theequipment works in an environment of proper temperature and humidity. This task is performedto reduce the possibility of equipment faults and to prolong the life span of the equipment.

2.10 Verifying the MSP SwitchingThe multiplex section protection (MSP) exercise switching can be performed to check whetherthe MSP protocol is normal. The exercise switching does not affect services.

2.11 Backing up the Database of the T2000Back up the database of the T2000. In this way, when the T2000 is upgraded or replaced, youcan directly read the data from the backup database instead of uploading the data from the NEside. This section describes how to back up the T2000 database.

2.12 Backing up Data of the ASON NEAfter you back up the ASON NE data, you can restore the NE data through the T2000 to preventservice loss if the database of the ASON NE is lost.

2.13 Maintenance Record TableRecord the maintenance operations by using the following table.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-2 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 27: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

2.1 Checking the Status of the NE and BoardsRegularly check the status of the NE and boards on the NE. In this way, the anomalies can bedetected and then handled in time.

Prerequisitel The T2000 must be started at the NM center.

l The NE data must be configured and the data must be uploaded to the T2000.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance Period

Daily

Tools, Equipment and Materials

T2000

Operation Criteria

The NE icon and boards icon should be displayed in green on the T2000, and their workingstatus is normal.

Procedure

Step 1 Click the shortcut icon in the T2000 Main Topology to click Legend. Then, the descriptionof NE status is displayed.

Step 2 Check the NE status in the T2000 Main Topology. Normally, The NE icon should be displayedin green and its working status is normal. If not, handle the problem with reference tothe following and the Troubleshooting manual.

l If the NE icon is grey and is present above the NE icon, it indicates that thecommunication between the T2000 and NE is interrupted.

l If the NE icon is red , it indicates that the highest severity level of the alarms generatedon the NE is critical.

l If the NE icon is orange , it indicates that the highest severity level of the alarmsgenerated on the NE is major.

l If the NE icon is yellow , it indicates that the highest severity level of the alarmsgenerated on the NE is minor.

l If the NE icon is slight-blue , it indicates that the highest severity level of the alarmsgenerated on the NE is warning.

l If is present above the NE icon, it indicates that the T2000 and the NE are inconsistentwith respect to the NE configuration data. In this case, upload the NE configuration data byreferring to the OptiX iManager T2000 Online Help.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-3

Page 28: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Step 3 Double-click the NE icon. The NE status displayed in the upper left portion of the NE slot layoutshould be Running Status. If the NE status is Status Unknown, it indicates that the NE failsto communicate with the T2000, or that the NE status cannot be detected because of a fault onthe equipment. Handle the problem with reference to Troubleshooting manual.

Step 4 Click the shortcut icon in the NE slot layout to display the description of board status.

Step 5 Query the working state of the board. The board icon should be white . If the board iconis of any other colors, take the following guidelines to handle the anomaly.

l If the board icon is slight-green , it indicates that the physical board is in position butthe logical board is not added on the T2000. Right-click the board, and choose Add PhysicalBoard from the shortcut menu.

l If the board icon is dark-green , it indicates that the board is fixed and cannot beremoved or managed.

l If the board icon is blue , it indicates that the board is in the running state but not inposition. In this case, the physical board is not in position but the logical board is added onthe T2000. Check the board on site to ensure that the board is installed and the board is inproper contact with the backplane.

l If the board icon is grey , it indicates that the board is in the installation state and isrunning abnormally. In this case, check whether the configuration data of the board is corrector whether the board becomes faulty.

l If the board icon is slight-grey , it indicates that no board is available in the slot.

l If is displayed in the lower right portion of the board icon, it indicates that the board isin the protection state. If the original working board is in the protection state, troubleshootthe board.

l If is displayed in the lower left portion of the board icon, it indicates that loopback is setto the board. Determine whether to release the loopback on the board as required.

----End

2.2 Browsing Network-Wide AlarmsRegularly browse alarms to detect and rectify faults in time.

Prerequisitel The T2000 must be started at the NM center.

l The NE data must be configured and the data must be uploaded to the T2000.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-4 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 29: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Operation CriteriaUse the T2000 to query the network-wide alarms. No new alarms exist.

NOTE

New alarms are the alarms generated during the query intervals.

Procedure

Step 1 Click in the upper right portion of the Main Topology of the T2000 to display theCurrent Alarms-[All Current Alarms]-Critical interface. You can browse the current criticalalarms.

NOTE

When the indicator is surrounded by a square frame , it indicates that there are critical alarmsto be acknowledged.

When the indicator is surrounded by a square frame and the square frame flashes, it indicates that there arenew critical alarms to be acknowledged.

The number in the middle of the indicator indicates the number of current network-wide uncleared criticalalarms. Keep the interface open when alarms are monitored.

Step 2 Select the new cleared alarms and check the alarm causes. Check whether these alarms indicateany probable faults by referring to the Alarms and Performance Events Reference andTroubleshooting.

Step 3 Select all the alarms and right-click Acknowledge. The cleared alarms disappear and are storedas history alarms.

NOTE

To query the history alarms, choose Fault > Browse History Alarm .

Step 4 Select the new uncleared alarms and then check the alarm causes. Handle the faults withreference to Troubleshooting manual.

Step 5 Click in the upper right portion of the Main Topology of the T2000 to browse the currentmajor alarm, and follow Step 2 to Step 4 to check and handle the new major alarms.

NOTE

When the indicator is surrounded by a square frame , it indicates that there are major alarmsto be acknowledged.

When the indicator is surrounded by a square frame and the square frame flashes, it indicates that there arenew major alarms to be acknowledged.

The number in the middle of the indicator indicates the number of current network-wide uncleared majoralarms. Keep the interface open when alarms are monitored.

Step 6 Click in the upper right portion of the Main Topology of the T2000 to browse the currentminor alarm, and follow Step 2 to Step 4 to check and handle the new minor alarms.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-5

Page 30: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

NOTE

When the indicator is surrounded by a square frame , it indicates that there are minor alarms tobe acknowledged.When the indicator is surrounded by a square frame and the square frame flashes, it indicates that there arenew minor alarms to be acknowledged.The number in the middle of the indicator indicates the number of current network-wide uncleared minoralarms. Keep the interface open when alarms are monitored.

----End

2.3 Browsing Abnormal EventsRegularly browse the performance events of an NE to check the running status of the equipment.In this case, possible hazards can be prevented in time.

Prerequisitel The T2000 must be started at the NM center.

l The NE data must be configured and the data must be uploaded to the T2000.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

Operation CriteriaNone

ProcedureStep 1 Choose Fault > Browse Event from the Main Menu of the T2000 to display the Events window

and filter dialog box.NOTE

If you previously set the startup template for browsing performance events (set the filter conditions), theFilter dialog box is not displayed. Instead, the performance events matching the startup template are directlydisplayed. For details on how to create a startup template, refer to the OptiX iManager T2000 Online Help.

Step 2 Optional: Click Copy from Template in the lower left corner in the Basic Settings tab orEvent Source tab to import the event browse template previously set. For details on how tocreate an event browse template by setting filter conditions, refer to the OptiX iManager T2000Online Help.

NOTE

The default event browse template covers all abnormal performance events and all NEs.

Step 3 Set the filter conditions for browsing performance events in the Basic Settings tab of theFilter dialog box.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-6 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 31: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

1. Optional: Select the Event Name check box and click . In the displayed SelectEvent dialog box that is displayed, select the performance events to be browsed, and thenclick OK.

2. In the Basic Settings tab of the Filter dialog box, set Severity, Type, and GeneratedTime for performance events.

3. Optional: Select the Remarks contain check box and enter the remarks made previouslyfor specific performance events in the text box behind the Remarks contain to filter theperformance events.

Step 4 In the Event Source tab of the Filter dialog box, select the NEs whose performance events areto be browsed.

1. Set the mode for selecting NEs in the Select Mode group box.

2. Adopt either of the following modes to select NEs whose performance events are to bebrowsed.

l Enter the key words of the NE name or NE type in the text box below Object name(By object) or Type (By type). (Fuzzy match is supported. For multiple conditions,separate them with a space.) Then, click Find. The matched NE names or NE types aredisplayed in the Navigation Tree.

l Select the NE name or NE type in the Object Navigation Tree (By object) or TypeNavigation Tree (By type).

Step 5 Click OK. The matched performance events, if there is any, are displayed in the Events window.

Step 6 For abnormal events, see Alarms and Performance Events Reference and Troubleshooting.

Step 7 Optional: Click Print or Save As to output the performance event data.

----End

2.4 Browsing the Current Performance EventsBrowse the current performance events to check the current running state of the equipment.Hence, the latent hazards can be cleared in time.

2.4.1 Browsing the Current SDH Performance EventsBrowse the current SDH performance events to check the current running state of the equipment,such as launched optical power, received optical power and temperature. Hence, the latenthazards can be cleared in time.

2.4.2 Browsing the Current Performance Events at the Ethernet PortBrowse the current performance events at the Ethernet port to check the running status of theEthernet board of the equipment. In this case, possible hazards can be prevented in time.

2.4.3 Browsing the Current Performance Events at the ATM PortBrowse the current performance events at the ATM port to check the running status of the ATMport. In this case, possible hazards can be prevented in time.

2.4.4 Browsing the Current VPI&VCI Performance Events at the ATM PortBrowse the current VPI&VCI performance events at the ATM port to check the running statusof the ATM port. In this case, possible hazards can be prevented in time.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-7

Page 32: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

2.4.1 Browsing the Current SDH Performance EventsBrowse the current SDH performance events to check the current running state of the equipment,such as launched optical power, received optical power and temperature. Hence, the latenthazards can be cleared in time.

Prerequisitel The T2000 must be started at the center.

l The equipment must work in the normal state, and the NE must be configured with theSDH data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the SDHperformance events. If the performance monitoring function is disabled, refer to the OptiXiManager T2000 Online Help to enable the performance monitoring function.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools and InstrumentsT2000

CriteriaUse the T2000 to browse the performance. The query covers the bit error and pointer justificationperformance, which should be in line with Table 2-1.

Table 2-1 Criteria for the check of bit error and pointer justification

Performance Type Criteria

Bit error RSBBE 0

MSBBE 0

HPBBE 0

LPBBE 0

Pointer justification AUPJCHIGH 0

AUPJCLOW 0

TUPJCHIGH 0

TUPJCLOW 0

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-8 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 33: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Procedure

Step 1 On the T2000, choose Performance > Browse SDH Performance from the Main Menu. Clickthe Current Performance Data option button.

Step 2 Select 15-Minute or 24-Hour for the Monitor Period field.

Step 3 In the left pane, select one or more NEs and boards, and click .

NOTEIf the target NE belongs to a subnet, first expand the subnet and then select the target NE.

Step 4 Click the Gauge tab, and choose Select All for the performance event type.

Step 5 Click Query to check if the performance value is normal.

Step 6 Click the Count option button. Select bit error or pointer justification performance event, andselect Display Zero Data for the Display Options.

Step 7 Click Query to check the performance value for bit error and pointer justification. Check if theperformance value is in line with Table 2-1.

NOTE

If not, refer to the "Troubleshooting Bit Errors" or "Troubleshooting Pointer Justification" section in theTroubleshooting.

----End

2.4.2 Browsing the Current Performance Events at the Ethernet PortBrowse the current performance events at the Ethernet port to check the running status of theEthernet board of the equipment. In this case, possible hazards can be prevented in time.

Prerequisitel The T2000 must be started at the NM center.

l The equipment must work in the normal state, and the NE must be configured with theEthernet data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the Ethernetperformance events. If the performance monitoring function is disabled, refer to the OptiXiManager T2000 Online Help to enable the performance monitoring function.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance Period

Daily

Tools, Equipment and Materials

T2000

Operation Criteria

None

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-9

Page 34: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Procedure

Step 1 On the T2000, right-click the NE icon in Main Topology and choose NE Explorer.

NOTEIf the NE to be queried belongs to a subnet, expand the subnet and then select the NE.

Step 2 Select the Ethernet board and choose Performance > RMON Performance from the FunctionTree.

Step 3 Click the Statistics Group tab.

Step 4 Select the Ethernet port whose performance events need to be queried. Set the QueryConditions and Display Mode according to the requirements.

NOTEIf the Query Conditions is set to Graphics, it is recommended that the maximum number of performanceevents that you can select at one time is 10.

Step 5 Click Start and wait for some time (10 to 15 minutes is recommended). Then, click Stop toquery the Ethernet performance events during this period.

NOTE

If performance statistics should be made again, click Resetting begins.

----End

2.4.3 Browsing the Current Performance Events at the ATM PortBrowse the current performance events at the ATM port to check the running status of the ATMport. In this case, possible hazards can be prevented in time.

Prerequisitel The T2000 must be started at the NM center.

l The equipment must work in the normal state, and the NE must be configured with theATM data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the ATMperformance events. If the performance monitoring function is disabled, refer to the OptiXiManager T2000 Online Help to enable the performance monitoring function.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance Period

Daily

Tools, Equipment and Materials

T2000

Operation Criteria

Table 2-2 lists the operation criteria for the current performance events at the ATM port.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-10 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 35: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Table 2-2 Operation criteria for the current performance events at the ATM port

Performance Event Standard

ATM_INGCELL The count of received cells is the same as theexpected value.

ATM_EGCELL The count of transmitted cells is the same as theexpected value.

ATM_CORRECTED_HCSERR The count of received corrected HCS error cells is0.

ATM_UNCORRECTED_HCSERR The count of received uncorrected HCS error cellsis 0.

ATM_RECV_CELL The count of received cells is the same as theexpected value.

ATM_RECV_IDLECELL The count of received idle cells is the same as theexpected value.

ATM_TRAN_CELL The count of transmitted cells is the same as theexpected value.

For the details on the handling method of performance events, refer to the Performance EventReferences of the equipment.

Procedure

Step 1 On the T2000, right-click the NE icon in the Main Topology and choose NE Explorer.

Step 2 Select the ATM board and choose Performance > ATM Performance Event MonitorStatus from the Function Tree.

Step 3 Select the related port from the list. Enable or disable the monitor period mode. Click Apply todisplay the Operation Result dialog box. Then, click Close.

Step 4 Choose Performance > ATM Performance Real-Time Monitor > Port PerformanceData from the Function Tree.

Step 5 Select the related port from Monitored Object.

Step 6 Select Monitor Period, Monitor Interval(s), and Display Number of Data Column.

Step 7 Click Reset & Start. After a period of time (10 to 15 minutes is recommended), click Stop.Browse and check the performance events at the ATM port during this period.

----End

2.4.4 Browsing the Current VPI&VCI Performance Events at theATM Port

Browse the current VPI&VCI performance events at the ATM port to check the running statusof the ATM port. In this case, possible hazards can be prevented in time.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-11

Page 36: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Prerequisitel The T2000 must be started at the NM center.

l The equipment must work in the normal state, and the NE must be configured with theATM data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the VPI&VCIperformance events at the ATM port. If the performance monitoring function is disabled,refer to the OptiX iManager T2000 Online Help to enable the performance monitoringfunction.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

Operation CriteriaTable 2-3 lists the operation criteria for the current VPI&VCI performance events at the ATMport.

Table 2-3 Operation criteria for the current VPI&VCI performance events at the ATM port

Performance Event Standard

ATM_CORRECTED_HCSERR The count of the received corrected HCS errorcells is 0.

ATM_UNCORRECTED_HCSERR The count of the received uncorrected HCS errorcells is 0.

ATM_RECV_CELL The count of the received cells is the same as theexpected value.

ATM_RECV_IDLECELL The count of the received idle cells is the same asthe expected value.

ATM_TRAN_CELL The count of the transmitted cells is the same asthe expected value.

For the details on the handling method of performance events, refer to the Performance EventReferences of the equipment.

Procedure

Step 1 On the T2000, right-click the NE icon in the Main Topology and choose NE Explorer.

Step 2 Select the ATM board and choose Performance > ATM Performance Event MonitorStatus from the Function Tree.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-12 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 37: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Step 3 Select the related port from the list. Enable or disable the monitor period mode. Click Apply todisplay the Operation Result dialog box. Then, click Close.

Step 4 Choose Performance > ATM Performance Real-Time Monitor > VPI&VCI PerformanceData from the Function Tree.

Step 5 Select the related port from Monitored Object.

Step 6 Select Monitor Period, VPI-VCI, Monitor Interval(s), and Display Number of DataColumn.

Step 7 Click Reset & Start. After a period of time (10 to 15 minutes is recommended), click Stop.Browse the VPI&VCI performance events at the ATM port and ensure that the performanceevents are normal.

----End

2.5 Browsing the History Performance EventsBrowse the history performance events to check the long-term running state of the equipment.Hence, the latent hazards can be cleared in time.

2.5.1 Browsing the History SDH Performance EventsBrowse the history SDH performance events to check the long-term running state of theequipment. Hence, the latent hazards can be cleared in time.

2.5.2 Browsing the History Performance Events at the Ethernet PortBrowse the history performance events to check the long-term running status of the Ethernetboard of the equipment. In this case, possible hazards can be prevented in time.

2.5.3 Browsing the History Performance Events at the ATM PortBrowse the history ATM performance events to check the long-term running status of the ATMport. In this case, possible hazards can be prevented in time.

2.5.4 Browsing the History VPI&VCI Performance Events at the ATM PortBrowse the history VPI&VCI performance events to check the long-term running status of theATM port of the equipment. In this case, possible hazards can be prevented in time.

2.5.1 Browsing the History SDH Performance EventsBrowse the history SDH performance events to check the long-term running state of theequipment. Hence, the latent hazards can be cleared in time.

Prerequisitel The T2000 must be started at the center.

l The equipment must work in the normal state, and the NE must be configured with theSDH data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the history SDHperformance events. If the performance monitoring function is disabled, refer to the OptiXiManager T2000 Online Help to enable the performance monitoring function.

l You must be an NM user with "NE monitor" authority or higher.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-13

Page 38: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

CriteriaTable 2-4 lists the main SDH history performance events and the check criteria.

Table 2-4 Main SDH history performance events and the check criteria

Performance Event 15-MinuteHighestThreshold

15-MinuteLowestThreshold

24-HourThreshold

AUPJCHIGH 1500 0 30000

AUPJCLOW 1500 0 30000

RSBBE 1500 300 15000

MSBBE 1500 300 15000

HPBBE 1500 300 15000

OSPITMPMAX 0 0 0

OSPITMPMIN 0 0 0

OSPITMPCUR 0 0 0

HPUAS 20 0 50

MSUAS 20 0 50

RSUAS 20 0 50

TLBMAX 0 0 0

TLBMIN 0 0 0

NOTE

l When an NE detects that a certain performance value reaches or exceeds the 15-minute or 24-hourthreshold, the NE reports a performance threshold crossing alarm.

For details on how to handle the performance events, refer to the Performance EventsReference.

Procedure

Step 1 On the T2000, choose Performance > Browse SDH Performance from the Main Menu. Clickthe History Performance Data option button.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-14 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 39: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Step 2 Select 15-Minute or 24-Hour for the Monitor Period field.

Step 3 Select one or more NEs and boards from the left pane and click .

NOTEIf the target NE belongs to a subnet, first expand the subnet and then select the target NE.

Step 4 Click From to set the time range.

Step 5 Select the Gauge option button and the performance event type.

Step 6 Select Data Source and click Query.

NOTE

If the history performance data is browsed for the first time, select Query from NE and Save toDatabase for the data source. Hence, for the next query, you can select Query from T2000 to browse thehistory performance data.

Step 7 Select the Count option button and the performance event type.

Step 8 Select Data Source and click Query.

----End

2.5.2 Browsing the History Performance Events at the Ethernet PortBrowse the history performance events to check the long-term running status of the Ethernetboard of the equipment. In this case, possible hazards can be prevented in time.

Prerequisitel The T2000 must be started at the NM center.

l The equipment must work in the normal state, and the NE must be configured with theEthernet data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the historyEthernet performance events. If the performance monitoring function is disabled, refer tothe OptiX iManager T2000 Online Help to enable the performance monitoring function.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

Operation CriteriaNone

Procedure

Step 1 On the T2000, right-click the NE icon in Main Topology and choose NE Explorer.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-15

Page 40: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

NOTEIf the NE to be queried belongs to a subnet, expand the subnet and then select the NE.

Step 2 Select the Ethernet board and choose Performance > RMON Performance from the FunctionTree.

Step 3 Click the History Control Group tab, and set the History Table Type, Sampling Period,Number of Items, and Monitor Status correctly. Click Query. A Operation Result isdisplayed to indicate that the operation is successful. Click Close.

NOTE

After History Table Type is set to Custom Period, you can set Sampling Period.

Step 4 Click the History Group tab.

Step 5 Select the Ethernet port whose performance events are to be browsed, and specify PerformanceEvents, History Table Type, and Display Mode. Specify Start Item and End Item in QueryConditions according to the requirements.

Step 6 Click Query to query the history performance events of the Ethernet port.

Step 7 In the Operation Result dialog box that is displayed, click Close.

----End

2.5.3 Browsing the History Performance Events at the ATM PortBrowse the history ATM performance events to check the long-term running status of the ATMport. In this case, possible hazards can be prevented in time.

Prerequisitel The T2000 must be started at the NM center.

l The equipment must work in the normal state, and the NE must be configured with theATM data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the history ATMperformance events at the ATM port. If the performance monitoring function is disabled,refer to the OptiX iManager T2000 Online Help to enable the ATM performance monitoringfunction.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance Period

Daily

Tools, Equipment and Materials

T2000

Operation Criteria

Table 2-5 lists the operation criteria for the history performance events at the ATM port.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-16 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 41: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Table 2-5 Operation criteria for the history performance events at the ATM port

Performance Event Standard

ATM_INGCELL The count of received cells is the same as theexpected value.

ATM_EGCELL The count of transmitted cells is the same as theexpected value.

ATM_CORRECTED_HCSERR The count of received corrected HCS error cells is0.

ATM_UNCORRECTED_HCSERR The count of received uncorrected HCS error cellsis 0.

ATM_RECV_CELL The count of received cells is the same as theexpected value.

ATM_RECV_IDLECELL The count of received idle cells is the same as theexpected value.

ATM_TRAN_CELL The count of transmitted cells is the same as theexpected value.

For the details on the handling method of performance events, refer to the Performance EventReferences of the equipment.

ProcedureStep 1 On the T2000, right-click the NE icon in the Main Topology and choose NE Explorer.

Step 2 Select the ATM board and choose Performance > ATM Performance Event MonitorStatus from the Function Tree.

Step 3 Select the related port from the list. Enable or disable the monitor period mode. Click Apply todisplay the Operation Result dialog box. Then, click Close.

Step 4 Choose Performance > ATM History Performance > Port Performance Data from theFunction Tree.

Step 5 Select the related port from Monitored Object.

Step 6 Choose Query Period and set the time range.

Step 7 Click Query, in the Operation Result dialog box that is displayed, click Close. Browse thehistory performance events and ensure that the history performance events at the ATM port arenormal.

----End

2.5.4 Browsing the History VPI&VCI Performance Events at theATM Port

Browse the history VPI&VCI performance events to check the long-term running status of theATM port of the equipment. In this case, possible hazards can be prevented in time.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-17

Page 42: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Prerequisitel The T2000 must be started at the NM center.

l The equipment must work in the normal state, and the NE must be configured with theATM data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the historyVPI&VCI performance events at the ATM port. If the performance monitoring function isdisabled, refer to the OptiX iManager T2000 Online Help to enable the ATM performancemonitoring function.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

Operation CriteriaTable 2-6 lists the operation criteria for the history VPI&VCI performance events at the ATMport.

Table 2-6 Operation criteria for the history VPI&VCI performance events at the ATM port

Performance Event Standard

ATM_CORRECTED_HCSERR The count of the received corrected HCS errorcells is 0.

ATM_UNCORRECTED_HCSERR The count of the received uncorrected HCS errorcells is 0.

ATM_RECV_CELL The count of the received cells is the same as theexpected value.

ATM_RECV_IDLECELL The count of the received idle cells is the same asthe expected value.

ATM_TRAN_CELL The count of the transmitted cells is the same asthe expected value.

For the details on the handling method of performance events, refer to the Performance EventReferences of the equipment.

Procedure

Step 1 On the T2000, right-click the NE icon in the Main Topology and choose NE Explorer.

Step 2 Select the corresponding ATM board and choose Performance > ATM Performance EventMonitor Status from the Function Tree.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-18 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 43: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Step 3 Select the related port from the list. Enable or disable the monitor period mode. Click Apply todisplay the Operation Result dialog box. Then, click Close.

Step 4 Choose Performance > ATM History Performance > VPI&VCI Performance Data fromthe Function Tree.

Step 5 Select the related port from Monitored Object.

Step 6 Choose Query Period and set the time range.

Step 7 Click Query, in the Operation Result dialog box that is displayed, click Close. Browse thehistory VPI&VCI performance events and ensure that the history VPI&VCI performance eventsat the ATM port are normal.

----End

2.6 Viewing the Timeslot Allocation DiagramTo check the timeslots used for the protection subnet and to ensure normal allocation, view thetimeslot allocation diagram.

Prerequisitel The T2000 must be started at the center.

l A protection subnet must be present.

l You must be a T2000 user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

CriteriaNone

Background InformationThe T2000 exports the timeslot assignment diagram in SVG format. To view or print thediagram, install the SVG Viewer. In the Windows operating system, refer to \client\SVG\PC\pcreadme.txt to install the SVG Viewer. In the UNIX operating system, refer to /client/SVG/Unix/unixreadme.txt.

ProcedureStep 1 Choose Inventory > Timeslot Allocation Diagram from the Main Menu. Then, the Generate

Timeslot Allocation Diagram dialog box is displayed.

Step 2 Select a protection subnet in the Generate Timeslot Allocation Diagram dialog box. ClickStart. The T2000 generates the timeslot allocation diagram of this protection subnet and saveit in the client\report directory.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-19

Page 44: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

NOTE

On UNIX, the timeslot allocation diagram that the T2000 automatically creates is saved in the client/report directory.

Step 3 Navigate to the client\report directory, double-click the SVG file to view the timeslot allocationdiagram.

TIP

If there are more than three NEs in a protection subnet, hold the Alt key and move the mouse simultaneouslyto view all the NEs in the timeslot allocation diagram.

----End

2.7 Querying Board Version InformationYou can query the board version mapping information in the board information report and boardmanufacturing information report.

Prerequisitel The T2000 must be started at the center.

l The board software must support the query of board version information.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

CriteriaThe BIOS, NE software, board software, logic, and PCB of a board should match the NE softwarewith regard to the version.

Procedure

Step 1 Query the board software version. For details, see "Querying the Board Information Report" inthe Supporting Task of this product. The query results are as follows:l The software version of the SCC board is the NE software version.

l The software version of each board is the board software version.

NOTE

The board software version must match the NE software version.

Step 2 Query the hardware version and logical version of the board. For details, see "Querying theBoard Manufacturer Information Report" in the Supporting Task of this product.

If the board name displayed (Board: NE Name - Slot ID - Board Name) on the T2000 isinconsistent with the board name displayed in the Board Type field, it indicates that the current

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-20 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 45: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

working board enables the board version replacement function. If the board names are consistent,it indicates that the board version replacement function is enabled for the current working board.

NOTE

In the case of board version replacement, the new board may not have certain functions that the old boardhas. Hence, ensure that the new board has all the functions that the old board has before using the boardversion replacement function.

Step 3 Optional: Click Print to print the report or click Save As to export the report.

----End

2.8 Checking the Optical PowerIf the mean launched optical power and the received optical power at the optical interface areexcessively high or low, the services are affected due to bit errors or damage to the opticalcomponents. To prevent this, you need to check the optical power periodically.

Prerequisitel The T2000 must be started at the center.

l The NE data must be configured, and the data must be uploaded to the T2000.

l The label of the board to be queried must be recorded. The label is used to determine thetype of the optical interface module.

l The function to monitor performance must be enabled. If the function to monitorperformance is not started, see the OptiX iManager T2000 Online Help to start the function.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance Period

Daily

Tools, Equipment and Materials

T2000

Criteria

See "Specifications of the Optical Interface" in Technical Specifications or in the engineeringdocument. Ensure that the input optical power and output power are within the normal rangespecified in the specifications and they do not cross the reference upper working threshold andreference lower working threshold.

Procedure

Step 1 See "Querying the Optical Power" in the Supporting Task of this product to query the opticalpower of the optical interface board. Query Input Power(dBm), Output Power(dBm),Reference Working Lower Threshold(dBm), and Reference Working Upper Threshold(dBm) of each optical interface of the optical interface board.l 5 dB less than the overload of the optical interface

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-21

Page 46: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

l 3 dB larger than the receiver sensitivity of the optical interface

Step 2 See "Specifications of the Optical Interface" in Technical Specifications or in the engineeringdocument. Ensure that the input optical power and output power are within the normal rangespecified in the specifications and not cross the Reference Working Lower Threshold(dBm) andReference Working Upper Threshold(dBm).

Step 3 If the requirements for the specifications are not met, see "Checking Optical Power" in theTroubleshooting to take corresponding measures.

----End

2.9 Checking the TemperatureMaintain the environment of the equipment room in a periodic manner to ensure that theequipment works in an environment of proper temperature and humidity. This task is performedto reduce the possibility of equipment faults and to prolong the life span of the equipment.

Prerequisitel The T2000 must be started at the NM center.

l The equipment must work in the normal state, and the NE must be configured with theSDH data and the data must be uploaded to the T2000.

l The performance monitoring function must be enabled before you browse the SDHperformance events. If the performance monitoring function is disabled, see the OptiXiManager T2000 Help to enable the performance monitoring function.

l You must be an NM user with "NE monitor" authority or higher.

Maintenance PeriodDaily

Tools, Equipment and MaterialsT2000

Operation CriteriaProper temperature and humidity should be maintained inside the equipment room for thetransmission equipment to work normally continuously, as shown in Table 2-7.

Table 2-7 Requirements on the environment where the board runs

Long-term/Short-term Temperature Humidity

Long-term operatingcondition

0°C to 45°C 10% to 90%

Short-term operatingcondition

-5°C to 55°C 5% to 95%

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-22 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 47: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Procedure

Step 1 Check the temperature of the board.1. On the T2000, choose Performance > Browse SDH Performance from the Main Menu.

Click the Current Performance Data option button.2. Select 15-Minute or 24-Hour for the Monitor Period field.

3. In the left pane, select one or more NEs and boards, and click .4. Click the Gauge tab, and choose Working Temperature for the performance event type.

Choose Display Current Value in the Display Options pane.5. Click Query and then click Close in the Operation Result dialog box. Confirm that the

temperature is within the normal range.

NOTEIf the temperature is beyond the normal range, see the Troubleshooting of the product to handle thecase.

Step 2 Check the temperature of the equipment room. This task is performed by the on-site maintenancepersonnel.1. Record the values that the thermometer and hygroscope in the equipment room read. The

normal value range is shown in Table 2-7.2. Ensure that the cabinet, equipment surface and interior, table top, and ground surface are

tidy and clean. No dust can be easily observed.

----End

2.10 Verifying the MSP SwitchingThe multiplex section protection (MSP) exercise switching can be performed to check whetherthe MSP protocol is normal. The exercise switching does not affect services.

Prerequisitel The T2000 must be started at the NM center.

l The equipment must be in normal communication with the T2000. The network must beconfigured with the MSP. No APS_INDI alarm occurs on the NE that is configured withthe MSP.

l You must be an NM user with "NE operator" authority or higher.

Maintenance Period

Quarterly

Tools, Equipment and Materials

T2000

Operation Criteria

Table 2-8 shows the excise ring switching in the East on the T2000.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-23

Page 48: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Table 2-8 Operation criteria for the MSP switching

Item Before theRingSwitching

Performing theRing Switching

After Clearingthe RingSwitching

Target node East Status Idle Exercise - Ring Idle

West Status Idle Idle Idle

Nodesconnected tothe target node

East Status Idle Idle Idle

West Status Idle Exercise - Ring Idle

Other nodes East Status Idle Pass - Through Idle

West Status Idle Pass - Through Idle

Procedure

Step 1 Choose Service > SDH Protection Subnet > SDH Protection Subnet Maintenance from theMain Menu on the T2000.

Step 2 In the SDH Protection Subnet Common Attributes window, select the MSP protection subnet.Then click Query. In normal cases, East Status and West Status of each node should be set toIdle, and Protocol Controller should be set to Protocol Started.

Step 3 Select a node and choose East > Exercise - Ring. The Protection Attributes dialog box isdisplayed. Then click Yes.

Step 4 In the Operation Result dialog box that is displayed, click Close. At this time, the status ofnodes should be as follows:l East Status of the selected node is Exercise - Ring and West Status is Idle.

l East Status of the node that is connected to East of the selected node is Idle and WestStatus is Exercise - Ring.

l East Status and West Status of other nodes are Pass - Through.

Step 5 Right-click the node selected in Step 3. Choose East > Clear All from the shortcut menu. ClickYes in the displayed dialog box. Then the Operation Result dialog box is displayed to indicatethat the operation is successful. Click Close. The directions of all the NEs should be Idle.

----End

2.11 Backing up the Database of the T2000Back up the database of the T2000. In this way, when the T2000 is upgraded or replaced, youcan directly read the data from the backup database instead of uploading the data from the NEside. This section describes how to back up the T2000 database.

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-24 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 49: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Prerequisitel On the UNIX platform, the current user should have the authority to write the Sybase

database. The T2000DBServer must be started.

l On the Windows platform, the current user must have the authority of administrator of theoperating system. The MS SQL server database must be started.

Maintenance Period

Monthly

Tools, Equipment and Materials

T2000

CAUTIONWhen use the backup database to restore the data for the upgrade or replacement of the T2000,confirm that the format of the backup database is not modified. Otherwise, the backup databaseis damaged and the upgrade or replacement then fails.

Procedure

Step 1 Start Database Management Tool.

l On the UNIX platform, right-click the CDE desktop and choose Tool > Terminal to displaya terminal window. Run the T2000DM.sh in the /T2000/server/database directory.

l On the Windows platform, display the Resource Manager window. Run the T2000DM.exein the C:\T2000\server\database directory.

NOTE

The previous example shows the default path where the T2000 is installed. The actual path may varywith the actual situations. It is subject to the actual path.

Step 2 Select T2000DBServer from the left Database Server List.

Step 3 In the displayed dialog box, enter the password of the user (sa).

NOTEThe password for the sa user is the password entered when the T2000 is installed. By default, the passwordis null.

Step 4 Click Backup Database to display a dialog box.

Step 5 Specify the directory where the backup database files are to be stored.

Step 6 Click Backup to start the backup of the T2000 database. Click Close after the backup iscomplete.

----End

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-25

Page 50: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

2.12 Backing up Data of the ASON NEAfter you back up the ASON NE data, you can restore the NE data through the T2000 to preventservice loss if the database of the ASON NE is lost.

Prerequisitel The NE data must be configured and the NE must run normally.

l You must be an NM user with "NE operator" authority or higher.

l The ASON features must be enabled on the NE.

Maintenance Period

Every two weeks

Tools, Equipment and Materials

T2000

Procedure

Step 1 Choose NE Software Management > Device Operation from the Main Menu on the T2000to enter Data Center.

Step 2 Click in the Device Operation Object Tree, and choose the type of the NE to be backedup.

NOTE

You can click to select the subnet that the NE to be backed up belongs to.

Step 3 Select one or more NEs to be backed up from Device View. Right-click the selected NE or NEsand choose Backup from the shortcut menu. Then, the Backup dialog box is displayed.

TIP

If there are multiple equipment, click Search on the Search tab. In the Search Device(s) dialog box thatis displayed, set Resource Type and Search Mode. Enter the keyword for searching in the Find Whatdialog box according to Search Mode.

Step 4 Select the path for backing up data in Backup To.l If you need to back up the data to the server, choose NMS Server.

l If you need to back up the data to the client, choose NMS Client. Click . In the Backupto client dialog box that is displayed, select the directory to back up the data and click OK.

– NOTE

To back up the data to the client, you need to start the FTP, SFTP, and TFTP protocols.

Step 5 Click Start to start the backup. The backup progress is displayed in Operation Status.

----End

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-26 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 51: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

2.13 Maintenance Record TableRecord the maintenance operations by using the following table.

Maintenance Item Maintenance Status Remarks Maintainer

Checking the status of the NEand boards

□Normal □Abnormal

Browsing network-wide alarms □Normal □Abnormal

Browsing abnormal events □Normal □Abnormal

Browsing the currentperformance events

□Normal □Abnormal

Browsing the historyperformance events

□Normal □Abnormal

Viewing the timeslot allocationdiagram

□Normal □Abnormal

Querying Board VersionInformation

□Normal □Abnormal

Checking the optical power □Normal □Abnormal

Checking the temperature □Normal □Abnormal

Verifying the MSP switching □Normal □Abnormal

Backing up the T2000 Database □Normal □Abnormal

Backing up data of the ASONNE

□Normal □Abnormal

Problems and their solution:

Pending problems:

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2 Guide for Routine Maintenance in the Center and RecordTable

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

2-27

Page 52: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Maintenance Item Maintenance Status Remarks Maintainer

Verification:

Date:

2 Guide for Routine Maintenance in the Center and RecordTable

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

2-28 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 53: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

3 Guide for On-Site Routine Maintenance andRecord Table

About This Chapter

This topic describes the items and methods for on-site routine maintenance.

3.1 Cleaning the Air FilterThe air filter is cleaned to ensure fine heat dissipation of the equipment. This section describeshow to clean the air filter.

3.2 Maintenance Record TableRecord the maintenance operations by using the following table.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 3 Guide for On-Site Routine Maintenance and Record Table

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

3-1

Page 54: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

3.1 Cleaning the Air FilterThe air filter is cleaned to ensure fine heat dissipation of the equipment. This section describeshow to clean the air filter.

Prerequisite

None

Maintenance Period

The maintenance period is adjustable according to the cleanness of the equipment room

l According to the environment defined in ETSI EN 300 019-2-3 class 3.1, the air filtershould be cleaned each three months.

l According to the environment defined in ETSI EN 300 019-2-3 class 3.2, the air filtershould be cleaned each month.

NOTE

During cable layout, do not block the air inlet (at the lower part of the cabinet) and the air outlet (at theupper part of the subrack and the top part of the cabinet). In addition, do not place any items on the top ofthe subrack to ensure the ventilation.

Tools, Equipment and Materials

None

Criteria

None

PrecautionsNOTE

Ensure that the air paths are not blocked. Ensure that the air intake vent (at the bottom of the cabinet) orair exhaust vent (at the top of the subrack and the top of the cabinet) are not blocked when you route thecables and fibers. Do not place any foreign items on the subrack that may block the air exhaut vent.

Procedure

Step 1 Draw out the air filter of the subrack. Reference Information shows where the air filter locatesin the subrack.

Step 2 Cleaning the Air Filter:

l OptiX OSN 2500, OptiX OSN 3500, OptiX OSN 3500 II, and OptiX OSN 7500: remove thesponge on the air filter and wash it with water. Then, have it blown to dry in a ventilate place.

l OptiX OSN 1500: clean the air filter and have it blown to dry in a ventilate place.

Step 3 After the cleaning:

3 Guide for On-Site Routine Maintenance and Record TableOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

3-2 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 55: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

l OptiX OSN 2500, OptiX OSN 3500, OptiX OSN 3500 II, and OptiX OSN 7500: stick thesponge back to the air filter. Push the air filter gently along the slide rail at the bottom of thesubrack.

l OptiX OSN 1500: push the air filter gently along the slide rail at the right of the subrack.

----End

Reference InformationFigure 3-1, , , , , and show where the air filter locates in the subrack.

Figure 3-1 Position of the air filter in the OptiX OSN 7500 subrack

Subrack

Fan tray assembly

Air filter

Insert

Remove

3.2 Maintenance Record TableRecord the maintenance operations by using the following table.

Maintenance Item MaintenanceCondition

Remarks Maintainer

Cleaning the air filter □Normal □Abnormal

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance 3 Guide for On-Site Routine Maintenance and Record Table

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

3-3

Page 56: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

Maintenance Item MaintenanceCondition

Remarks Maintainer

Problems and their solution:

Pending problems:

Verification:

Date:

3 Guide for On-Site Routine Maintenance and Record TableOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

3-4 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 57: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

4 Guide for Routine Maintenance of the SpareParts and Record Table

About This Chapter

This topic describes the items and methods for routine maintenance of the inventory center.

4.1 Testing the Spare PartsThe spare parts should be maintained so that they are ready to be used. Thus, the time taken toreplace the parts then can be effectively decreased.

4.2 Maintenance Record TableRecord the maintenance operations by using the following table.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

4 Guide for Routine Maintenance of the Spare Parts andRecord Table

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

4-1

Page 58: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

4.1 Testing the Spare PartsThe spare parts should be maintained so that they are ready to be used. Thus, the time taken toreplace the parts then can be effectively decreased.

PrerequisiteImportant boards must be available in the inventory center.

Maintenance PeriodYearly

Tools, Equipment and MaterialsT2000

CriteriaThe spare boards and the boards that are used on the network should be the same in BIOS version,SCC software version, board software version, and logic version.

NOTE

A portion of the boards of different PCB versions are mutually compatible. If the PCB versions of the spareparts are different from those of the running boards, consult local Huawei technical support engineers.

Procedure

Step 1 See "Querying the Board Information Report" in the Supporting Task of this product to querythe board information report and record the software version of each board, including thefollowing:l Version of the SCC board, that is, NE software version

l Version of the software of each board, that is, board software version

Step 2 See "Querying the Board Manufacturer Information Report" in the Supporting Task of thisproduct to query the board manufacturing information report and record the bar codes of theboards, types of the optical interfaces, and information of optical modules.

Step 3 Test the spare parts to ensure they are ready for use.

----End

Reference InformationFollow the listed principles to maintain the spare parts.

l Principle for check of spare parts:– Check the version and quality of spare parts periodically.

– The spare boards and the boards used in the network should be the same in BIOS version,SCC software version, board software version, and logic version.

4 Guide for Routine Maintenance of the Spare Parts andRecord Table

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

4-2 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 59: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

– When the network is to be upgraded, provide the parts in time and upgrade the versionof the running parts.

NOTE

If the board belongs to the multiple ID board, see "Board Version Replacement" for board compatibilityand replacement.

l Principle for storage of parts:– The spare parts must be stored in line with regulations and be kept for exclusive use.

– The spare parts must be stored in shielding bag and no friction should be caused amongthem. These bags with parts inside should be kept in special antistatic cupboard andaway from sundries.

– Wear an antistatic glove to touch the spare parts.

– The inbound/outbound information must be recorded and timely refreshed. Hence, theparts can be supplemented accordingly.

4.2 Maintenance Record TableRecord the maintenance operations by using the following table.

Maintenance Item MaintenanceCondition

Remarks Maintainer

Testing the Spare Parts □Normal □Abnormal

Problems and their solution:

Pending problems:

Verification:

Date:

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance

4 Guide for Routine Maintenance of the Spare Parts andRecord Table

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

4-3

Page 60: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf
Page 61: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

A Glossary

B

Backup A method to save the data to prevent damage to the original data.

Bit Error An error to some bits in the digital code stream after receiving,generation. Bit errors accompany the damage to the transmittedinformation.

C

Client A terminal (computer or workstation) that sends signaling to the serverand displays the result on the user interface.

ConfigurationData

A command file for an NE which defines the configuration of the NEhardware. With the file, the NE can coordinate with other NEs in theentire network. Configuration data is the key factor for the normalrunning of the entire network.

CurrentPerformance Data

Performance data stored in the current register. An NE provides twotypes registers for each performance parameter of the performancemonitoring entity. The registers are 15-minute register and 24-hourregister, which are used to accumulate the performance data within thecurrent monitoring period.

E

Ethernet A data line level protocol that consists of the two bottom layers of theOSI model. Several physical media, such as twisted pairs and co-axialcables, can be used for the Ethernet broadcast network topology. TheEthernet uses the CSMA/CD and TCP/IP to detect conflict.

Exercise RingSwitching

An operation to exercise the ring protection switching for specificchannels by issuing commands. The bridging and switching is notactually performed. Commands are issued and the response result ischecked. However, services are not affected.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance A Glossary

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

A-1

Page 62: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

ExerciseSwitching

An operation to check if the protection switching protocol functionsnormally. The protection switching is not really performed.

F

Fault A failure to implement the function while the specified operations areperformed. A fault does not involve the failure caused by preventivemaintenance, insufficiency of external resources and intentionalsettings.

H

HistoryPerformance Data

The performance data that is stored in the history register or that is auto-reported and stored in the T2000.

L

Laser A component that generates directional optical waves of narrowwavelengths. The laser light has better coherence than ordinary light.The fiber system takes the semi-conductor laser as the light source.

Loopback A process to locate the fault by looping back the optical interface,electrical interface or the path. There are three loopback modes: non-loopback, outloop and inloop.

M

Main Topology A basic component of man-machine interface for the T2000. The maintopology displays the networking details and the basic informationabout NEs, alarms of subnets, communication status.

Mean LaunchedOptical Power

Mean optical power at S reference point that coupled into fibers whenonly pseudo-random codes are transmitted.

MPLS A versatile solution to address the problems faced by present-daynetworks—speed, scalability, quality-of-service (QoS) management,and traffic engineering.

N

NE Network element that contains hardware and the software running onthe hardware. Generally, one network element should contain one SCCboard at least, which manages and monitors the entire network element.The NE software runs on the SCC board.

A GlossaryOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

A-2 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)

Page 63: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

NE Explorer A main operation interface of the T2000. An expandable object tree(function tree) is absent at the left-down pane of the interface. The usercan fast locate the operation object from the object tree and then performconfiguration, management and maintenance accordingly.

O

Optical Interface A component that connects several transmit or receive units.

Output OpticalPower

A parameter that indicates the optical power of the output signals.

P

Pass-Through To transmit the received service to the next station without processing.

Protection Subnet A network-level concept for the T2000 rather than a pure MS ring orpath protection ring in the NES or RMS+ network management system.A protection subnet consists of NEs and fiber connections. Sufficientresources are available to create a subnet on the condition that NEs arecreated, configured and fiber connections among NEs are correctlyestablished.

U

Upload An operation to report some or all configuration data of an NE to theT2000. The configuration data then covers the configuration data storedat the T2000 side.

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance A Glossary

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

A-3

Page 64: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf
Page 65: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

B Acronyms and Abbreviations

A

ATM Asynchronous Transfer Mode

I

IP Internet Protocol

M

MPLS MultiProtocol Label Switching

MSP Multiplex Section Protection

O

ODF Optical Distribution Frame

S

SDH Synchronous Digital Hierarchy

U

UPS Uninterruptible Power Supply

V

VCI Virtual Channel Identifier

VPI Virtual Path Identifier

OptiX OSN 7500 Intelligent Optical Switching SystemRoutine Maintenance B Acronyms and Abbreviations

Issue 01 (2009-08-14) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

B-1

Page 66: 81939887-OptiX-OSN-7500-Routine-BSNL.pdf

B Acronyms and AbbreviationsOptiX OSN 7500 Intelligent Optical Switching System

Routine Maintenance

B-2 Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.

Issue 01 (2009-08-14)