    SOFTWARE VERSION 2.00

    DIGITAL COMMUNICATOR RESET:Installer lock must be unlocked.

    (Address 049: enter any value other than 147)Power down reset(1) Remove the auxiliary power* (12 volts).(2) Connect a jumper between "reset jumper" pins.

    (3) Connect the auxiliary power* (12 volts).(4) Wait 5 seconds.

    (5) Remove jumper.

    * Refer to the wiring diagram on the last page.

    Factory default installer code will be reinstated. Values entered at addresses 008-043, 086-094 and 300-547, will beerased ([2ND] [2ND]). Programmed values of all other addresses do not change.

    HEXA PROGRAMMING:All digits from 0 to F are valid. Values are programmed into memory locations from address 000 to 043 and from address300 to 547.

    1) Press [ENTER] + installer code.2) [ENTER] will flash (programming mode).

    3) Enter 3 digit memory address.4) Current value will be displayed on keypad.5) Enter 2 digit data.6) Go to step 3 for next address.To exit programming mode, press [CLEAR].

    STREAMLINED SECTION PROGRAMMINGCan be used to program sections 00 to 72. (addresses 000 to 043 and 300 to 547)Press [ENTER], installer code, and [7]. ([2ND] and [ENTER] keys alternately flash.)Enter a 2-digit section number, followed by 8 digits to program that section (confirmation beep). Data will be saved

    automatically and the software advances to the next programming section. To exit programming mode press [CLEAR].

    INSTALLER CODE: (reset code 707070) (addresses 000, 001, 002) SECTION 00Full access to programming and can be used to modify installer code. Use only numeric keys from [1] to [10] to programthe installer code (key [10] = 0)

    PANEL ANSWER OPTIONS: (address 003) SECTION 00First digit disables Answering Machine Override (key [2ND] or key [1]), or determines period of time between first andsecond call (see table below). Second digit determines number of rings required before panel will answer. If [2ND][2ND] isentered, panel will not answer. (Default value is [2ND] [8].)

    1

    708EPE-0

    KEYPAD TROUBLE DISPLAYKey "ON" =

    [7] Communicator report failure[8] Timer loss*[10] Telephone line failure[12] Serial cable not connected

    *To clear timer loss trouble, see Key Access Programming[MEM].Press [CLEAR] to clear troubles.

    Dialer circuit is patent pending.

    ANSWERING MACHINE OVERRIDE

    [2ND] or [1] = disabled [5] = 40 seconds[2] = 16 seconds [6] = 48 seconds[3] = 24 seconds [7] = 56 seconds[4] = 32 seconds [8] to [F] = 60 seconds

    HEXA DISPLAYValue of

    2ND digit = 10(8 + 2 = 10)

    Value of

    1ST digit = 3(2 + 1 = 3)VALUE = "3A"

    No display = SKIP (empty) No light = 0

    10 = [0] = [A]

    If key is lit = 8 = 4 = 2 = 1

    If key is lit = 8 = 4 = 2 = 1

  • 8/14/2019 708 manual.pdf

    2/13

    TELEPHONE AND ACCOUNT NUMBERS: (reset empty )

    If only one central station phone number is used, program the same number for telephone number 1 and 2.[10] = the number "0" [BYP] = switch from pulse to tone while dialing[11] = * [MEM] = pause 4 seconds[12] = # [TRBL] = end of number

    COMPUTER TELEPHONE NUMBER: (View at addresses 008 to 015.)Streamline Streamline

    section section

    02__ / __ / __ / __ / __ / __ / __ / __ 03__ / __ / __ / __ / __ / __ / __ / __1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    CENTRAL STATION TELEPHONE NUMBER 1: (View at addresses 016 to 023.)Streamline Streamline

    section section

    04__ / __ / __ / __ / __ / __ / __ / __ 05__ / __ / __ / __ / __ / __ / __ / __1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    CENTRAL STATION TELEPHONE NUMBER 2: (View at addresses 024 to 031.)Streamline Streamline

    section section

    06__ / __ / __ / __ / __ / __ / __ / __ 07__ / __ / __ / __ / __ / __ / __ / __1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    ACCOUNT "A" AND "B": (View at addresses 032 to 035.)Streamline

    section

    08___ / ___ / ___ / ___ ___ / ___ / ___ / ___1 2 3 4 5 6 7 8

    A B

    If only one account number is required, the same number must be entered for both account "A" and "B".

    For 3 digit account num-bers enter "skip" ([2ND])as first digit.

    Press [TRBL] to end phone

    number if less than 16digits are programmed.

    Press [TRBL] to end phonenumber if less than 16digits are programmed.

    Press [TRBL] to end phonenumber if less than 16digits are programmed.

    2

    PG708

  • 8/14/2019 708 manual.pdf

    3/13

    DECIMAL PROGRAMMING3 Digit Decimal Value ProgrammingUsed to program addresses 044 to 049. Values entered must contain 3 digits between 000 and 255. ([10] = 0)

    Decimal value programming:1) Press [ENTER] + installer code. ([ENTER] key will flash)2) Enter 3 digit address (044 to 049).3) Current value will be displayed on keypad.

    4) Enter 3 digit DECIMAL value.

    5) Repeat from step 2 onward for next address.

    To exit programming mode press [CLEAR].

    044:___/___/___ (days) Auto test report every ? days (between 001 and 255) (000 = disabled)

    045:___/___/___ (hours) Auto test report (between 000 and 023)

    046:___/___/___ (minutes) Auto test report (between 000 and 059)

    047:___/___/___ ( x 15mSec.) Zone speed (factory default 600mSec.)

    048:___/___/___ PGM timer setting (001 to 127 for seconds and 129 to 255 for minutes) (factory default 5 seconds)

    049:___/___/___ Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 + 128 = 133)Installer code lock (147 = locked, 000 = unlocked)

    COMMUNICATOR FORMATS

    Key[2ND] = ADEMCO slow (1400Hz, 1900Hz, 10bps) [6] = RADIONICS with PARITY (1400Hz, 40bps)

    [1] = (1400Hz, 1800Hz, 10bps) [7] = RADIONICS with PARITY (2300Hz, 40bps)

    [2] = SILENT KNIGHT fast (1400Hz, 1900Hz, 20bps) [8] = ADEMCO express[3] = SESCOA (2300Hz, 1800Hz, 20bps) [9] = ADEMCO contact ID (programmable codes)[4] = RADIONICS (40bps with 1400Hz handshake) [10] = ADEMCO contact ID (all codes)[5] = RADIONICS (40bps with 2300Hz handshake) [TRBL] = DTMF - no handshake (personal dialing)

    3

    PG708

  • 8/14/2019 708 manual.pdf

    4/134

    PG708

    Programmable Output (PGM) Types (Address 039 1st digit)

    Regular N.O. Solid state switch conducts to negative (50mA*) upon an event or events, and returns to to its original state

    (N.O.) once the conditions that triggered it have terminated.

    Regular N.C. Solid state switch opens circuits from ground upon an event or events and returns to its original state (N.C.once the conditions that triggered it have terminated.

    Timed N.O. Solid state switch conducts to negative (50mA*) upon an event or events and remains activated for the

    amount of time programmed at address 048.

    Timed N.C. Solid state switch opens circuits from ground upon an event(s) and remains activated for the amount o

    time programmed at address 048.

    "or" logic Causes the programmable output command to occur when one or more selected events from a specified

    group of events take place (example: key [1] or [2] is pressed on keypad.)

    "and" logic Causes the programmable output command to occur when all selected events from a specified group o

    events take place (example: key [1] and key [2] are pressed.)

    "equal" logic Causes the programmable output command to occur when all events from a specified group of events take

    place (example: key [1] and [2] are pressed but [3], [4], [5], [6], [2ND] and [TRBL] are not pressed.)

    *UL tested for 30mA only.

    PROGRAMMABLE CONTACT ID EVENT CODES

    All addresses from 300 to 547 (sections 11 to 72) programmed with values other than [2ND] [2ND] will report the contactID codes corresponding to the values programmed. Values to be programmed should be selected from this table.

    CID REPORTING CODE PROG. VALUE CID REPORTING CODE PROG. VALUE100: AUXILIARY ALARM [2ND] / [1] 300: SYSTEM TROUBLE [2] / [2]

    110: FIRE ALARM [2ND] / [2] 301: AC LOSS [2] / [3]

    111: FIRE SMOKE [2ND] / [3] 302: LOW SYSTEM BATTERY [2] / [4]

    112: COMBUSTION [2ND] / [4] 305: SYSTEM RESET [2] / [5]

    113: WATER FLOW [2ND] / [5] 306: PROGRAM CHANGED [2] / [6]

    114: HEAT [2ND] / [6] 309: BATTERY TEST FAIL [2] / [7]115: PULLSTATION [2ND] / [7] 320: SOUNDER/RELAY TROUBLE [2] / [8]116: DUCT [2ND] / [8] 321: BELL 1 TROUBLE [2] / [9]117: FLAME [2ND] / [9] 323: ALARM RELAY TROUBLE [2] / [10]

    118: NEAR ALARM [2ND] / [10] 350: COMMUNICATION TROUBLE [2] / [11]

    120: PANIC ALARM [2ND] / [11] 351: TELCO 1 FAULT [2] / [12]

    121: DURESS [2ND] / [12] 354: FAIL TO COMMUNICATE [2] / [BYP]

    122: SILENT PANIC [2ND] / [BYP] 370: PROTECTION LOOP TROUBLE [2] / [MEM]

    123: AUDIBLE PANIC [2ND] / [MEM] 371: PROTECTION LOOP OPEN [2] / [TRBL]

    130: BURGLARY [2ND] / [TRBL] 372: PROTECTION LOOP SHORT [3] / [2ND]

    131: PERIMETER BURG. [1] / [2ND] 373: FIRE LOOP TROUBLE [3] / [1]132: INTERIOR BURG. [1] / [1] 382: SENSOR TROUBLE [3] / [2]133: 24HR BURGLARY [1] / [2] 383: SENSOR TAMPER [3] / [3]136: BURGLARY OUTDOOR [1] / [3] 400: OPEN/CLOSE [3] / [4]

    137: BURGLARY TAMPER [1] / [4] 401: OPEN/CLOSE BY USER # [3] / [5]

    138: BURGLARY NEAR ALARM [1] / [5] 402: GROUP O PEN/CLOSE [3] / [6]

    140: GENERAL ALARM [1] / [6] 403: AUTOMATIC OPENING/CLOSING [3] / [7]

    150: 24 HOUR AUX [1] / [7] 404: LATE TO OPEN/CLOSE [3] / [8]

    151: GAS DETECTED [1] / [8] 407: REMOTE ARM DOWNLOAD [3] / [9]152: REFRIGERATION [1] / [9] 410: REMOTE ACCESS [3] / [10]

    153: LOSS OF HEAT [1] / [10] 541: OPEN/CLOSE - STAY MODE [3] / [11]154: WATER LEAKAGE [1] / [11] 570: BYPASS [3] / [12]155: FOIL BREAK ALARM [1] / [12] 572: 24 HOUR ZONE BYPASS [3] / [BYP]156: DAY TROUBLE ALARM [1] / [BYP] 573: BURGLARY BYPASS # [3] / [MEM]

    157: LOW GAS LEVEL [1] / [MEM] 574: GROUP BYPASS [3] / [TRBL]

    158: HIGH TEMPERATURE [1] / [TRBL] 601: MANUAL TEST [4] / [2ND]

    159: LOW TEMPERATURE [2] / [2ND] 602: PERIODIC TEST [4] / [1]

    161: LOSS AIR FLOW [2] / [1] 625: TIME/DATE RESET [4] / [2]

  • 8/14/2019 708 manual.pdf

    5/13

    FEATURE SELECT PROGRAMMINGAddresses 086-094. ON/OFF status of the key lights determines feature selection.In programming mode, enter 3 digit memory address (086 to 094). To sabe entries, press [ENTER].To exit programming mode press [CLEAR]. Reset = OFF for addresses 086 to 094.

    5

    PG708

  • 8/14/2019 708 manual.pdf

    6/13

    REPORTING CODES: (reset code = empty" [2ND] [2ND])All digits from [1] to [F] are valid. Enter [2ND] (skip) = digit will not be reported except for contact I.D. programmable codes.

    For single digit reporting enter "skip" ([2ND]) as first digit.

    If CONTACT I.D. format (all codes) is selected, addresses 300 to 547 (sections 11 to 72) do not have to be programmed.(Select Contact I.D (all codes) - key [10] for both central station numbers at section 09 - address 038.)

    6

    PG708

  • 8/14/2019 708 manual.pdf

    7/137

    PG708

  • 8/14/2019 708 manual.pdf

    8/138

    PG708

  • 8/14/2019 708 manual.pdf

    9/139

    PG708

  • 8/14/2019 708 manual.pdf

    10/1310

    KEY ACCESS PROGRAMMINGPrograms features quickly, without entering addresses or section numbers.

    To activate key access programming, press [ENTER], followed by installer. Press the key corresponding to the desiredfeature. Press [ENTER] or [CLEAR] to exit.

    key

    [MEM] "Digital communicator time" and clear trouble 8Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes.

    [BYP] Test reportReporting is enabled at address 086 keys [4], [5]. A value must be entered at address 532, and both telephoneand account numbers must be programmed.

    [TRBL] Call Espload via telephoneCommunicator and PC ID numbers (addresses 001-004) and PC download phone number (addresses 008-015)must be programmed.

    [AWAY] Answer EsploadThis feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in "modem

    setup" section, and communicator phone number programmed (works also without ADP-1).

    [STAY] Cancel communication attemptsStops all communication until next reportable event

    [7] Streamlined value entry

    Note: When communicating with Espload, it is impossible to enter programming mode.

    PG708

  • 8/14/2019 708 manual.pdf

    11/13

  • 8/14/2019 708 manual.pdf

    12/13

    FCC WARNINGS ESPRIT 708IMPORTANT INFORMATION

    This equipment complies with Part 68 of the FCC rules. Inside the cover of this equipment is a label that contains, among other

    information, the FCC registration number of this equipment.

    NOTIFICATION TO TELEPHONE COMPANY

    Upon request, customer shall notify telephone company of particular line to which the connection will be made, and provide the FCC

    registration number and the ringer equivalence of the protective circuit.

    FCC REGISTRATION NUMBER:5A7CAN-22633 - AL - ERINGER EQUIVALENCE NUMBER: 0.1B

    USOC JACK: RJ31X (USA), CA31A (CANADA)

    TELEPHONE CONNECTION REQUIREMENTS

    Except for telephone company-provided ringers, all connections to telephone network shall be made through standard plugs and

    telephone company-provided jacks, or equivalent, in such a manner as to allow for easy, immediate disconnection of terminal

    equipment. Standard jacks shall be so arranged that, if plug connected thereto is withdrawn, no interference to operation of equipment

    at customer's premises which remains connected to telephone network shall occur by reason of such withdrawal.

    INCIDENCE OF HARM

    Should terminal equipment/protective circuitry cause harm to telephone network, telephone company shall, where practicable, notify

    customer that temporary disconnection of service may be required; however, where prior notice is not practicable, the telephone

    company may temporarily discontinue service if action is deemed reasonable in circumstances. In case of temporary discontinuance,

    telephone company shall promptly notify customer and will be given opportunity to correct the situation.

    CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES

    The telephone company may make changes in its communication facilities, equipment operations or procedures, where such actionsare reasonably required and proper in its business. Should any such changes render customer's terminal equipment incompatible with

    the telephone company facilities, the customer shall be given adequate notice to effect the modifications to maintain uninterrupted

    service.

    GENERAL

    This equipment shall not be used on coin telephone lines. Connection to party line service is subject to state tariffs.

    RINGER EQUIVALENCE NUMBER (REN)The REN is useful to determine the quantity of devices that you may connect to your telephone line and still have all of those devices

    ring when your telephone number is called. In most, but not all areas, sum of the REN's of all devices connected to one line should not

    exceed five (5.0). To be certain of the number of devices that you may connect to your line, you may want to contact your local

    telephone company.

    EQUIPMENT MAINTENANCE FACILITY

    If you experience trouble with this telephone equipment, please contact facility indicated below for information on obtaining service orrepairs. The telephone company may ask that you disconnect this equipment from network until problem is corrected or until you are

    sure that the equipment is not malfunctioning.

    U.S. POINT OF CONTACT:Wackenhut International Inc.

    10446 N.W. 31 terrace

    Miami, Florida

    33172 USA 1-305-994-8167

    FCC PART 15, WARNINGS INFORMATION TO USERThis equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of FCC rules.

    These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment

    generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause

    harmful interference to radio communications.

    However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmfu

    interference to equipment intermittently, the user is encouraged to try to correct the interference by one or more of the following

    measures: (1) reorient or relocate the receiving antenna; (2) increase the separation between the equipment and receiver; (3) connect

    the equipment to an outlet on a circuit other than the one to which the receiver is connected, or (4) consult the dealer or an

    experienced radio/tv technician for assistance.

    CAUTION: Changes or modifications not expressly approved by PARADOX SECURITY SYSTEMS could void the user'sauthority to operate the equipment.

    NOTE: The FCC/IC sticker included with this module must be placed on the metal box in which the module is installed.

  • 8/14/2019 708 manual.pdf

    13/13

    ATTACHMENT LIMITATION NOTICE ESPRIT 708The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications

    network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's

    satisfaction.

    Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local

    telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should

    be aware that compliance with the above conditions may not prevent degradation of service in some situations.

    Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs

    or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause torequest the user to disconnect the equipment.

    Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal

    metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

    CAUTION

    Users should not attempt to make such connections themselves, but should contact the appropriate electrical inspection authority, or

    electrician, as appropriate.

    The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop

    which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only

    to the requirement that the total of the Load Numbers of all of the devices does not exceed 100. The Load Number of this unit is 33.

    Industry Canada certification is only applicable to installation of devices which include transformers approved by the Canadian

    Standards Association (CSA).

    NOTE: The FCC/IC sticker included with this module must be placed on the metal box in which the module is installed.

    RESTRICTIONS CONCERNANT LE RACCORDEMENT DE MATRIEL

    L'tiquette dIndustrie Canada identifie le matriel homologu. Cette tiquette certifie que le matriel est conforme certaines normes

    de protection, d'exploitation et de scurit des rseaux de tlcommunications. Le Ministre n'assure toutefois pas que le matrie

    fonctionnera la satisfaction de l'utilisateur.

    Avant d'instal ler ce matriel, l'utilisateur doit s'assur qu'il est permis de le raccorder aux installations de l'entreprise locale de

    tlcommunication. Le matriel doit galement tre install en suivant une mthode accepte de raccordement. L'abonn ne doit pas

    oublier qu'il est possible que la conformit aux conditions nonces ci-dessus n'empchent pas la dgradation du service dans

    certaines situations.

    Les rparations de matriel homologu doivent tre effectues par un centre d'entretien canadien autoris dsign par le fournisseur.

    La compagnie de tlcommunications peut demander l'utilisateur de dbrancher un appareil la suite de rparations ou de

    modifications effectus par l'utilisateur ou cause dun mauvais fonctionnement.

    Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise la terre de la source d'energie lectrique, des lignes

    tlphoniques et des canalisations d'eau mtalliques, s'il y en a, sont raccords ensemble. Cette prcaution est particulirement

    importante dans les rgions rurales.

    AVERTISSEMENT

    L'utilisateur ne doit pas tenter de faire ces raccordements lui-mme; il doit avoit recours une service d'inspection des installations

    lectriques, ou un lectricien, selon le cas.

    "L'indice de charge (IC) assign chaque dispositif indique, pour viter toute surcharge, le pourcentage de la charge totale qui peut

    tre raccorde un circuit tlphonique boucl utilis par ce dispositif. La terminaison du circuit boucl peut tre constitue de

    n'importe quelle combinaison de dispositifs, pourvu que la somme des indices de charge de l'ensemble des dispositifs ne dpasse pas

    100." L'indice de charge de ce produit est 33.

    La certification d'Industrie Canada s'applique seulement aux installations d'appareils utilisant un transformateur approuv par

    l'Association Canadienne de Normalisation (CSA).

    NOTE: Ltiquette FCC/IC incluse avec ce module doit tre colle sur la bote de mtal dans laquelle le module est install.