7/23/2019 4. Haz Area Lighting
1/44
Product Description Area Page
Series Classification No.
Incandescent
AEV Incandescent Zone 1 5-2
AEVA-EOLA Obstruction Marker Zone 1 5-6
T100A Small Bulkhead Luminaire Zone 1 5-7
Fluorescent
eLLK92 Ceiling Mount Lighting Fixtures Zone 1 5-8
eLLM92 Pole Mount Lighting Fixtures Zone 1 5-11
eLL92 Emergency Lighting Fixtures Zone 1 5-13
AEVF Exd Fluorescent Luminaires Zone 1and Zone 21&22 5-15
NDFA Exn/DIP Heavy Duty Fluorescent Zone 2and Zone 21&22 5-16
nLLK Exn/DIP Fluorescent Lighting Fixtures Zone 2and Zone 21&22 5-18
H.I.D.
AEVBH Large Bulkhead Luminaire Zone 1
and Zone 21&22 5-20
EVM Hazard Gard HID Lighting Fixtures Zone 1Integral Ballast Factory Sealed and Zone 21&22 5-21
EVME Exde Hazard Gard HID Lighting Fixtures Zone 1Integral Ballast and Zone 21&22 5-26
NVMV Champ HID Exn / DIP Zone 2Lighting Fixtures and Zone 21&22 5-34
Floodlights
NFMV Exn Floodlight Luminaire Zone 2and Zone 21&22 5-39
Beacons
FSFB301 Flashing Beacon Zone 1
and Zone 21&22 5-42FRFB301 Rotating Beacon Zone 1
and Zone 21&22 5-43
5-1Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Hazardous Area Lighting
7/23/2019 4. Haz Area Lighting
2/44
5-2Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
AEV
Incandescent
Lighting Fixtures
Application:AEV incandescent lighting fixtures are
used:
In locations which are hazardousdue to the presence of flammable
vapours or gases and where
dampness or corrosion are present
In petroleum refineries, chemicaland petrochemical plants and other
process industry facilities where
similar hazards exist
As pendant, ceiling, wall bracket orbulkhead fixtures indoors for general
area or room lighting, or outdoors for
"spot" lighting
Features:
Factory sealed - no external sealneeded
Easy to assemble and relamp Shock absorbing receptacle
Gasket seals out dirt and liquids
Positive locking of globe holder Inner reflector eliminates upwardspill light
Light weight, corrosion resistant,copper-free aluminium
Standard Materials:
Body and guard ........ Copper freealuminium
Glass ..... configurated glass, heatand impact resistant
Standard Finish: Body and guard ....................Greypolyurethane
Size Ranges:
20mm through 40mm hubs
Capacity Ranges:
100W to 300W incandescent 160Wself ballasted mercury vapour
25W SL fluorescent lamp
Options:
Reflectors Exit Sign AEVX ........ SeeAccessories on page 5-4
Temperature Classification to AS2480Incandescent Self-Ballasted Mercury SL FluorescentLamp Size T Rating Lamp Size T Rating Lamp Size T Rating100W T5 160W T4 18W T6150W T5 25W T6
200W T5300W T4
Compliances:
AS2380 Electrical equipment forexplosive atmospheres - Flameproof
enclosure
AS1939 - Degrees of Protection IP66 Certificate of Compliance No. Ex 491
Flameproof, Exd, IIC, IP66
Zone 1
7/23/2019 4. Haz Area Lighting
3/44
5-3Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Max. Lamp Hub WallSize Style Size Pendant Ceiling Bracket Bulkhead
With- 20mm AEVA211 AEVCX211 AEVBX211 AEVJ211150W Incandescent Guard 25mm AEVA221 AEVCX221 AEVBX221 AEVJ221
SL 18W Fluorescent Without- 20mm AEVA210 AEVCX210 AEVBX210 AEVJX210Guard 25mm AEVA220 AEVCX220 AEVBX220 AEVJX220
With - 20mm AEVA311 AEVCX311 AEVBX311 AEVJ311300W Incandescent Guard 25mm AEVA321 AEVCX321 AEVBX321 AEVJ321
SL25W Fluorescent Without- 20mm AEVA310 AEVCX310 AEVBX310 AEVJ310
160W S/B M/V Guard 25mm AEVA320 AEVCX320 AEVBX320 AEVJ320Notes:1: Ratings are for lamp base up mounting2: AEVBX and AEVJ fixtures take 30 angle reflectors only
Dimensions:20mm 25mm
Max. Lamp Size Type A B C D E F F150W AEVA 184 322 298Incandescent AEVCX 184 347 324 16 20SL18 Fluorescent AEVBX 184 390 368 318 16 20
AEVJ 184 359 337 244 238
300W AEVA 216 375 343Incandescent AEVCX 216 397 368 16 20SL25 Fluorescent AEVBX 216 441 413 333 16 20160W S/B M/V AEVJ 216 413 384 267 260Notes:1: Ratings are for lamp base up mounting2: When angle reflectors are used, dimension "b" should be changed as follows: add 70mm to AEVA, AEVBX and AEVCX fixtures.
Add 76mm to AEVJ fixtures.3. Remove reflector for application with SL25W lamp
Ordering Information:
7/23/2019 4. Haz Area Lighting
4/44
5-4Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Replacement Parts & Accessories
Receptacles, Guards, Glass &Holder Assemblies
Glass &Lamp Holder
Fixture Receptacle Guards AssembliesSize Cat. No. Cat. No. Cat. No.
100W-150W EV60 EV505 EV78
200W-300W EV60 EV502 EV7202
Exit Sign CoverCat. No. AEVXA3584
Reflectors
Material: Dome and 30 angle ... white fibreglass reinforcedpolyester (Krydon)
High bay ... etched Alzak aluminium with natural finish
Max. Lamp Size Style Diam. Cat. No.
150W incandescent} Dome 300mm RD6318W fluorescent 30Angle 300mm RA63
300W incandescent Dome 400mm RD72
25W fluorescent } 30 Angle 400mm RA72250W S/B M/V High Bay 370mm EV2912
Photometric Data
Fixture with glass,
30 angle reflectorwithout guard
Lamp : 200W
TotalLumens Eff%
WithGuard 2090 55.0WithoutGuard 2481 65.3
Measurements taken from A-A' plane
High Bay
Lamp Receptacles
30 Angle Guards
DomeGlass and holder assemblies
7/23/2019 4. Haz Area Lighting
5/44
5-5Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Photometric Data
Fixture with glass andwith or without guard
Lamp Data: 100W through 300WNote: All data provided is for 200W incandescent lamp.Use following candlepower / lumens multipliers for other lamp sizes: 100W 0.44; 150W 0.72; 300W 1.57
Example: Zonallumens for 200Wlamp without guardfor 20-30 is 218.Zonal lumens for150W lamp for 20-
30 is 218 x 0.72=157
Example: Zonallumens for 200Wlamp without guardfor 20-30 is 366.Zonal lumens for
150W lamp for 20-30 is 366 x 0.72=263
Coefficient of UtilisationEffective Floor Cavity Reflectance 20%
% Reflectance Room Cavity RatioEff.Ceil. Wall 1 2 3 4 5
50 .706 .601 .521 .457 .40380 30 .659 .537 .451 .382 .330
10 .618 .483 .395 .326 .275
50 .671 .572 .497 .435 .38470 30 .629 .513 .432 .367 .316
10 .590 .465 .380 .314 .265
50 .605 .515 .449 .393 .34950 30 .571 .468 .395 .336 .291
10 .541 .426 .351 .292 .247
50 .545 .464 .404 .355 .31630 30 .519 .426 .361 .308 .266
10 .494 .392 .324 .269 .229
50 .491 .416 .363 .319 .28410 30 .469 .385 .327 .280 .244
10 .449 .358 .296 .247 .210% Reflectance Room Cavity Ratio
Eff.Ceil. Wall 6 7 8 9 1050 .362 .324 .291 .265 .234
80 30 .290 .254 .224 .200 .17010 .238 .207 .177 .155 .129
50 .345 .310 .279 .254 .22370 30 .278 .244 .216 .192 .165
10 .228 .199 .171 .151. .126
50 .313 .282 .254 .232 .20550 30 .256 .224 .200 .178 .153
10 .214 .185 .160 .141 .117
50 .284 .255 .232 .212 .18730 30 .236 .208 .183 .164 .140
10 .198 .171 .149 .131 .107
50 .257 .233 .210 .192 .17010 30 .215 .191 .168 .151 .128
10 .183 .158 .138 .121 .099
Coefficient of UtilisationEffective Floor Cavity Reflectance 20%
% Reflectance Room Cavity RatioEff.Ceil. Wall 1 2 3 4 5
50 .700 .618 .547 .485 .43280 30 .672 .576 .497 .428 .373
10 .648 .540 .457 .385 .330
50 .685 .606 .538 .476 .42370 30 .659 .566 .490 .424 .369
10 .636 .535 .453 .382 .328
50 .655 .583 .519 .459 .41050 30 .635 .550 .478 .414 .362
10 .617 .520 .445 .378 .325
50 .629 .561 .501 .444 .39730 30 .613 .534 .466 .405 .254
10 .597 .509 .437 .373 .321
50 .607 .541 .484 .430 .38510 30 .593 .518 .455 .395 .348
10 .580 .498 .430 .367 .317% Reflectance Room Cavity Ratio
Eff.Ceil. Wall 6 7 8 9 1050 .389 .350 .316 .289 .252
80 30 .331 .294 .261 .234 .19710 .290 .255 .221 .196 .162
50 .383 .345 .312 .285 .24870 30 .328 .328 .259 .232 .197
10 .287 .252 .220 .196 .162
50 .370 .335 .302 .277 .24250 30 .322 .284 .254 .228 .194
10 .285 .250 .219 .195 .161
50 .360 .324 .294 .270 .23530 30 .316 .281 .249 .224 .191
10 .283 .247 .217 .193 .159
50 .349 .317 .286 .262 .23010 30 .310 .277 .246 .221 .188
10 .279 .245 .216 .191 .158
Fixture with glass, domereflector and with or without guard
7/23/2019 4. Haz Area Lighting
6/44
5-6Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
AEV-EOLA
Obstruction Marker
Application:AEV incandescent lighting fixtures are
used:
To aid aircraft navigation inhazardous locations
To mark towers and processcolumns in petroleum refineries or
chemical process plants
To indicate the presence of drilling
rigs or other industrial facilities
Features:
Easy to assemble and re-lamp Lightweight, corrosion resistant,copper free aluminium
Red fresnel prismatic lens ensureshigh visibility and avoids glare (other
colours also available upon request)
Available in single or double units,pipe or base mount versions
1 x M20 entry (other entries
available upon request)
Standard Materials:
Body and guard - Copper freealuminium
External Lens - Configurated glass,heat treated and impact resistant
Internal Lens - Coloured glass withfresnel configuration
Standard Finish:
Body and guard - Greypolyurethane
Size Ranges: 150W (max) 240/250VIncandescent
Compliances:
AS2380 Electrical equipment forexplosive atmospheres - Flameproof
enclosure
AS1939 - Degrees of ProtectionIP66
Certificate of Compliance No.Ex 491
Flameproof, Exd, IIC, IP66
Zone 1
TypeOrder
Code
Entry
Size
Incandescent
Lamp
Lamp
Holder
Single Unit
Pipe MountAEVA-EOLA1* 1 x M20 150W Max E27
Double Unit
Pipe MountAEVA-EOLA2* 1 x M20 150W Max E27
Single
Base MountAEVCX-EOLA1* 4 x M20 150W Max E27
Ordering Information
Dimensions:
7/23/2019 4. Haz Area Lighting
7/44
5-7Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
T100A Small
Bulkhead
Luminaire
Application:
For use in hazardous areas wherespace is limited and local lighting is
required
In areas where low mounting heightrequires a fixture with a low profile
For wall mounting in confinedspaces such as inspection pits
For mounting in pre-cast recesses
Features:
Cast aluminium body with flatimpact resistant glass, cast guard and
mounting feet
The lamp housing is separate fromthe terminal housing which allows
direct connection to circuit wiring
without the use of high temperature
cable.The terminal housing is
accessible by means of an inspection
cover
Internal LPF control gear forfluorescent and HID lamps
Three 25mm entries, 1 on eachside and 1 in the end
Reduced maintenance costs whenused with long life HID light sources
Standard Materials:
Body and guard........ Copper freealuminium
Lens...Heat resistant borrosilicateglass
Standard Finish:
Natural
Compliances:
AS2380 Electrical equipment forexplosive atmospheres - Flameproof
enclosure
AS1939 - Degrees of ProtectionIP66
Certificate of Compliance No.Ex618
Electrical Rating:
Incandescent .....................100W
Mercury vapour ................... 50W High pressure sodium ......... 35W Fluorescent (SL type lamp) ..18W Fluorescent (PL) type lamp) . 9W All types .................... 240V/50Hz
Ordering Information:Lamp Size & Type Cat. No. Temperature Rating
100W Incandescent T100A T3
18W SL type fluorescent T18-SL T6
9W PL type fluorescent T09-PL T6
Dimensions:
Flameproof, Exd, IIB, IP66
Zone 1
Hazardous
5Area
Lighting
7/23/2019 4. Haz Area Lighting
8/44
5-8Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Compliances:
EN50014, EN50019, EN50018,Electrical apparatus for potentially
explosive atmospheres, General
Requirements, Increased Safety e,
Flameproof Enclosure d
EN60529 Specification for degreesof protection provided by enclosures
(IP Code) IP66
PTB ATEX 96 2144 SAA Aus Ex 3558X
Ordering Information:Type Lamps Rated Power Temp. Catalogue
Current Factor Class No.
eLLK92018/18 2 x 18W 0.18A 0.95 T4 1 2265 875 111eLLK92036 1 x 36W 0.18A 0.95 T4 1 2263 875 103
eLLK92036/36 2 x 36W 0.34A 0.95 T4 1 2266 875 111
eLLK92058 1 x 58W 0.27A 0.95 T4 1 2264 875 111
eLLK92058/58 2 x 58W 0.53A 0.95 T4 1 2267 875 111
Bi Pin Fluorescent Lamp
eLLK92 Series
Fluorescent
Lighting Fixtures
Application:
Suitable for use in areas wherehazardous liquids, gases or vapours
are present during normal operation
Suitable for arduous conditions orextreme environments
Ideal for walkways, bridges,tunnels, security lighting, roadways
and process plants where reliable
lighting is required for safe operation
Low profile for use in areas wherevery low mounting heights or other
space restrictions exist
Features:
Incorporates CEAG designedelectronic ballasts which are suitable
for use with bi-pin (to IEC 81)
fluorescent lamps
Electronic ballast provides highluminous efficiency, lower energy
consumption and longer service life
of the lamps
Central locking system operatedby standard SW13 hex socket key
enables fixture to be opened from
single point on fixture housing
Diffuser fastened by 10, 20 and 24latch points respectively on 18W,
36W, and 58W fixtures
Diffuser hinges from either sideand is also designed to act as a
convenient lamp support when open
to simplify lamp replacement
Automatic disconnect switchensures the isolation of all exposedcomponents when the fixture is
opened
Lamp operation on twin lampfixtures is independent so that failure
of one does not affect the other
Large internal terminal compartmentwith twist locking knob on the cover
enables ready wiring access
Supplied as standard with 2 x M20metal entries at each end, complete
with through wiring facility
Wide voltage range
Standard Materials:
Housing .... Glass-mat reinforcedpolyester
Diffuser ........... Polycarbonate
Electrical Ratings:
Operating VoltageAC 110 to 254 V 10% 47 - 63HZ
DC 110 to 230 V 10%
Lamp configurations2 x 18W, 1 x 36W, 2 x 36W,
1 x 58W, 2 x 58W
Bi-pin 26mm diameter
Terminals ...... L1, L2, L3, L, N, PE6mm2 maximum, 1 wire per terminal
Ambient Temperature Range .....-25 C to +50 C
Options:
Alternate entry sizes available,consult factory for details
Increased Safety, Exde, IIC, IP66
Zone 1
7/23/2019 4. Haz Area Lighting
9/44
5-9Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
eLLK92058 & eLLK92058/58
Dimensions:
eLLk92018/18
Mounting Accessories:
Eye bolt A2Cat No. 2 2480 002 000
Hex Screw S4Cat No. 2 2480 054 000
Ceiling Mount D2Cat No. 2 2480 102 000
Note: Supplied as sets of two
eLLK92036 & eLLK92036/36
Pipe Clamp
Type Pipe Diameter Height H Cat No:
R12 38-42mm 85mm 2 2480 462 000
R22 47-50mm 95mm 2 2480 472 000
R32 58-62mm 105mm 2 2480 482 000
Dimensions
& Mounting Accessories
7/23/2019 4. Haz Area Lighting
10/44
5-10Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Rated luminous flux of lamps 2 x 18 W = 2,700 ImLight efficiency in operation:2 x 18 W = 78%Illumination data acc. to LiTG B 30
1 x 36 W Fixture
Rated luminous flux of lamps 1 x 36 W = 3,350 lmLight efficiency in operation:1 x 36 W = 86%Illumination data acc. to LiTG B 30
Rated luminous flux of lamps 2 x 36 W = 6,700 lmLight efficiency in operation:2 x 36 W = 78%Illumination data acc. to LiTG B 30
2 x 36 W Fixture
1 x 58 W Fixture
Rated luminous flux of lamps 1 x 58 W = 5,200 lm
Light efficiency in operation:1 x 58 W = 81%Illumination data acc. to LiTG B 30
Rated luminous flux of lamps 2 x 58 W = 10,400 lm
Light efficiency in operation:2 x 58 W = 72%Illumination data acc. to LiTG B 30
2 x 58 W Fixture
Photometric Data
2 x 18 W Fixture
7/23/2019 4. Haz Area Lighting
11/44
5-11Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Ordering Information:Type Lamps Rated Power Temp. Catalogue
Current Factor Class No.
eLLM92018/18 2 x 18W 0.18A 0.95 T4 1 2268 875 101
eLLM92036/36 2 x 36W 0.34A 0.95 T4 1 2269 875 101
eLLM92 Series
Fluorescent Pole
Lighting Fixtures
Application:
Suitable for use in areas wherehazardous liquids, gases or vapours
are present during normal operation
Suitable for arduous conditions orextreme environments
Ideal for walkways, bridges,security lighting, roadways and
process plants where reliable
lighting is required for safe operation
To provide overhead lighting frompole end mount position
Features:
Incorporates CEAG designedelectronic ballasts which are suitable
for use with bi-pin (to IEC 81)
fluorescent lamps
Electronic ballast provides highluminous efficiency, lower energy
consumption and longer service life
of the lamps
Integral pole mounting sleeverecessed into housing for 44mmpipe (1 1/4 nominal bore)
Large terminal compartmentreadily accessible and located
beneath pole mount
Central locking system operatedby standard SW13 hex socket key
enables fixture to be opened from
one point on housing
Diffuser fastened by 10, 20 and 24latch points respectively on 18W,
36W and 58W fixtures
Diffuser hinges from either sideand is also designed to act as aconvenient lamp support when open
to simply lamp replacement
Automatic disconnect switchensures the isolation of all exposed
components when the fixture is
opened
Lamp operation on twin lampfixtures is independent so that failure
of one does not affect the other
Supplied with 25mm cable glandfor 8-17mm cable
Wide voltage rangeStandard Materials:
Housing ....Glass-mat reinforcedpolyester
Diffuser .......... Polycarbonate
Electrical Ratings:
Operating VoltageAC 110 to 254 V 10% 47 - 63HZ
DC 110 to 230 V 10%
Lamp configurations........2 x 18W, 2 x 36W
Bi-pin 26mm diameter
Terminals ...... L1, N, PE, 2 x 6mm21 wire per terminal
Ambient Temperature Range .....-25 C to +50 C
Options:
Accessory kit for single endedthrough wiring comprising adaptor
with 2 x M25 cable glands...........
.................Cat No. 2 2218 602 000
Bi Pin Fluorescent Lamp
Compliances:
EN50014, EN50019, EN50018,Electrical apparatus for potentially
explosive atmospheres, General
Requirements, Increased Safety e,
Flameproof Enclosure d
EN60529 Specification for degrees
of protection provided by enclosures
(IP Code) IP66
PTB96 ATEX 2144 SAA Aus Ex 3558X
Increased Safety, Exde, IIC, IP66/67
Zone 1
7/23/2019 4. Haz Area Lighting
12/44
5-12Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
2 x 18 W Fixture
Rated luminous flux of lamps 2 x 18 W = 2,700 Im
Light efficiency in operation:2 x 18 W = 6,700 ImIllumination data acc. to LiTG B 30
Rated luminous flux of lamps 2 x 36 W = 6,700 lm
Light efficiency in operation:2 x 36 W = 78%Illumination data acc. to LiTG B 30
2 x 36 W Fixture
Dimensions & Photometric Data
Photometric Data:
eLLM Pole Mount
Dimensions:
Wall Mount Bracket W26Cat No. 2 2485 027 000
Mounting Accessories:
Standard Through wiringoption
Internal View ofTerminal Compartment
7/23/2019 4. Haz Area Lighting
13/44
5-13Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Standard Materials: Housing .... Glass-mat reinforcedpolyester
Diffuser ......... Polycarbonate
Electrical Ratings: Operating VoltageAC 220 to 254 V 10% 47 - 63HZ
Lamp configurations2 x 18W, 2 x 36WBi-pin 26mm diameter
Terminals ...... L1, L2, L3, L, N, PE6mm2 maximum, 1 wire per terminal Ambient Temperature Range .....
-5 C to +50 C
Emergency operation single lampfor 1.5 hour or 3 hour, set by internalwire terminal link
eLLK92036/36NiB
Emergency
Lighting Fixtures
Bi Pin Fluorescent Lamp
Application: Suitable for use in areas wherehazardous liquids, gases or vapoursare present during normal operation
Suitable for arduous conditions orextreme environments
In applications where lighting mustbe maintained under emergencyconditions to ensure safe evacuationof personnel
Ideal for walkways, bridges, tunnels,roadways and process plants where
reliable lighting is required for safeoperation
Features: Incorporates CEAG designedelectronic ballasts which are suitablefor use with bi-pin (to IEC 81)fluorescent lamps
Electronic ballast provides highluminous efficiency, lower energyconsumption and longer service life ofthe lamps
Intelligent microelectronic controllermonitors battery charge cycleeliminating overcharge and ni-clad
memory effect, extending battery life Battery charge level indicated bygreen LED display
Indicates when an operatingduration test is necessary at six monthintervals as required by safetyregulations
Indication provided after durationtest if a malfunction is apparent
Battery set can be safely replacedwithin hazardous environment
Emergency operation can be set for1.5 or 3 hour duration
Central locking system operated bystandard SW13 hex socket key
enables fixture to be opened from onepoint of housing
Diffuser fastened by 10 and 20 latchpoints respectively on 18W and 36Wfixtures
Diffuser hinges from either side andis also designed to act as aconvenient lamp support when opento simplify lamp replacement
Automatic disconnect switchensures the isolation of all exposedcomponents when the fixture isopened
Lamp configuration on twin lampfixtures is dependent so that failure of
one does not affect the other Incorporates inhibit function set byinternal wire terminal link to disableemergency operation for when poweris intentionally removed. Link can alsobe wired as external switch, for up to10 fixtures per switch
Ordering Information:Ceiling Mounted Emergency Fittings
Type Lamps Rated Power Temp. Catalogue
Current Factor Class No.eLLK92018/18NiB 2 x 18W 0.23A 0.95 ind T4 1 2260 879 111eLLK92036/36NiB 2 x 36W 0.4A 0.95 ind T4 1 2261 879 111
Pole Mounted Emergency FittingType Lamps Rated Power Temp. Catalogue
Current Factor Class No.eLLM92018/18NiB 2 x 18W 0.23A 0.95 ind T4 1 2273 879 101
Compliances: EN50014, EN50019, EN50018, EN50028,EN50020 Electrical apparatus forpotentially explosive atmospheres,General Requirements, IncreasedSafety e, Flameproof Enclosure d,Encapsulation m, Intrinsic Safety i
EN60529 Specification for degreesof protection provided by enclosures(IP Code) IP66
PTB96 ATEX2144
SAA AUS Ex 3558X
Increased Safety, Exdem ib, IIC, IP66
Zone 1
Hazardous
5Area
Lighting
7/23/2019 4. Haz Area Lighting
14/44
5-14Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Features, Dimensions
& Photometric Data
eLLk92018/18 Ni Ceiling Mount - Emergency
eLLK92036/36 Ni Ceiling Mount - Emergency
eLLM92018/18 Ni Pole Mount - Emergency
Dimensions:
Photometric Data:
Emergency Operation:Apply the following luminous flux factors when determiningperformance under emergency single lamp operation:
18 W = approx. 1.5 h 90% / 3.0 h 45%36 W = approx. 1.5 h 45% / 3.0 h 25%Rated luminous flux of lamps:1 x 18 W = 1,350 Im1 x 36 W = 3,350 lm
Charge status indicatedby green LED display
Microelectronic controllermonitors charge cycle,eliminating over charge and
Ni-cad memory effect
Flashing red LED indicateswhen an operating durationtest is necessary at sixmonth intervals as requiredby safety regulations
Battery set is replaceablewithin hazardous area
Red LED continues to
flash after duration test ifa malfunction is apparent
Battery temperature ismonitored during chargecycleOperation:
Status of the battery charge cycle is indicated by aseries of five green Light Emitting Diodes (LED), eachof which represents 20% of battery capacity.The levelof charge attained is indicated by the leading greenLED which flashes.The charge cycle is complete whenall five green LEDs are on.
Emergency operation commences on mains failureor when the main supply is switched off. Duringemergency operation the remaining battery capacity isindicated by the number of LEDs which are on.
The red LED begins flashing after six months fromthe last successful emergency duration test, or whenduring battery discharge a defective power supply or
fluorescent lamp is detected.The red LED will continueto flash until a successful duration test is completed.
Mounting Accessories: Refer to pages 5-9 and 5-12
7/23/2019 4. Haz Area Lighting
15/44
5-15Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
AEVF Series
Explosionproof
FluorescentLighting Fixture
Application:AEVF Luminaires are used to illuminateareas where hazardous liquids, fumes
or gases are present. Areas such as:
Spray Booths Drum Filling Areas Process Plants Combustible dusts present
Features: Luminaire has been designed toutilise the latest technology of compact
fluorescent lamps
Cast aluminium body with screwthreaded construction
Integral control gear in fullyaccessible compartment
Stainless steel guard and reflector Mounting feet facilitate mounting oneither wall or ceiling
Ease of installation Reduced initial cost
Reduced maintenance cost
Can be supplied with specialEmergency Exit sign
Can be supplied with externalEmergency Battery Pack for 2 hoursstandby lighting
Standard Materials:
Body ......... copper free aluminium Stainless steel guard and reflector
Standard Finish:
Grey polyurethane
Electrical Rating: 240V 50Hz Twin and single lamps PL18, PL24,PL36. 18, 24 and 36W respectively
Compliances:
AS2380 Electrical equipment forexplosive atmospheres - Flameproof
enclosure
AS2236 Electrical equipment forexplosive atmospheres - Dust excluding
Ignition proof
AS1939 Degrees of Protection IP66 Certificate of Compliance No. Ex933X
Options:
Emergency Exit Sign ........... NCE Emergency Lighting Battery Pack....................................................NC
Pole Mount ..............................PM
Utilisation factors: UF (F) SHR NOM = 1.75Roomreflectance Room Index
C W F .60 .75 .801.00 1.251.50 2.002.50 3.00 4.00 5.00.70 .50 .20 .22 N/A .24 .26 .29 .31 .35 .37 .38 .40 .42
.30 .19 N/A .21 .23 .26 .28 .32 .34 .36 .38 .40
.10 .14 N/A .17 .20 .23 .26 .29 .32 .34 .36 .38.50 .50 .20 .14 N/A .23 .25 .28 .30 .33 .35 .36 .38 .39
.30 .18 N/A .20 .22 .25 .27 .30 .32 .34 .36 .38
.10 .15 N/A .17 .19 .22 .25 .28 .30 .32 .35 .36.30 .50 .20 .20 N/A .22 .24 .26 .28 .31 .32 .34 .36 .37
.30 .15 N/A .18 .21 .24 .26 .29 .31 .32 .34 .35
.10 .13 N/A .16 .19 .22 .24 .27 .29 .31 .33 .34.00 .00 .00 .13 N/A .16 .17 .20 .22 .25 .26 .28 .30 .31Rating: Photometrically tested without ceiling board.Multiply values by service corrections factors.Calculated in accordance with CIBS Technical Memorandum No. 5 1980.
Ordering Information:Cat. No. No. & Size of Lamps Entries Temp Rating
AEVF118 1 x 18W 2 x 25mm T5AEVF136 1 x 36W 2 x 25mm T5AEVF218 2 x 18W 2 x 25mm T5AEVF236 2 x 36W 2 x 25mm T5
Dimensions: (mm)
Flameproof, Exd, IIB, IP66
Zone 1
Combustible DustZone 21 & 22
Hazardous
5Area
Lighting
7/23/2019 4. Haz Area Lighting
16/44
5-16Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Application: For use in locations where aconcentration of flammable gases orvapours may occur as the result ofan abnormal situation
Suitable for DIP locations such asgrain handling facilities or otherareas where hazardous dusts fibres& flyings are present and may
become suspended in theatmosphere or settle on equipmentor ledges
Ideal for walkways, bridges,tunnels, security lighting, roadwaysand process plants where reliablelighting is required for safe operation
For arduous conditions or extremeenvironments
Low profile for use in areas wherevery low mounting heights or otherspace restrictions make installationdifficult
Features: Three different mountingarrangements available:Ceiling mountPipe mountHanger mount
Corrosion resistant FRP housingmakes it ideal for installations inareas where corrosive and / or wetconditions exist during normal plantoperation
Noryl clips secure prismaticdiffuser to the body to ensurereliable sealing while still allowing
ease of relamping and maintenance A reliable seal between body anddiffuser is provided by a closed cellnon aging rubber gasket
Prismatic Diffuser eliminates glarewithout diminishing the amount ofilluminance
Reflector / gear tray is suspendedon hangers for ease of installationand maintenance
Standard Materials: Body ......... Grey FRP (Fibreglassreinforced polyester)
Prismatic Diffuser .......... Mouldedpolycarbonate Gasket ........... Polyurethane foam Quick Release Clips .......... Noryl Cable entry ........................Brass
Standard Finishes: Body .....................................Grey Prismatic Diffuser ................ Clear
Options:(Refer to ordering information)
Through wiring ...... Terminal block
at each end of the fixture internallywired (4mm2) to facilitate ease ofconnection
Hanger Mounting ...... Eye Boltsallow for suspension of the fixture byeither chain or steel cable
Pipe Mounting ..Brackets to allowsuspension from a pipe stanchion orwall bracket
Emergency Lighting Pack .....integral power pack to give 2 hoursstandby lighting in the event of apower supply failure
Non standard voltages
Stainless Steel quick-release clips Other entries available uponrequest
Electrical Ratings: 240 V, 50 Hz standard. Othervoltages and frequencies on request
18W, and 36W Temperature rating....
Exn - T3, DIP - T5
Compliances: Australian Standard 2238 ElectricalEquipment for explosiveatmospheres ............. Non-sparkingapparatus.Type of Protection n.Certificate of Compliance Ex1153x
Australian Standard 2236 ElectricalEquipment for explosiveatmospheres ........... Dust-excludingignitionproof enclosure. Certificate ofCompliance Ex1149DIP
Australian Standard 1939 Degreesof Protection of electrical equipmentIP66
Robustdiffuser clips
Brass entry
NDFA
Heavy Duty
FluorescentLighting Fixtures
Non-Sparking, Exn, IIC, IP66/67
Zone 2
Combustible DustZone 21 & 22
7/23/2019 4. Haz Area Lighting
17/44
5-17Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Ordering Information
Mounting Accessories :Lighting fixtures supplied completewith ceiling mount brackets. Order pipeclamps and eye bolts separately ifrequired. Two required per fixture.
Eye boltCat No. EBM6SS
Ceiling Mount Bracket
Pipe Clamp
Pipe Diameter Height H Cat No:
38-42mm 85mm UN8-43
47-50mm 95mm UN8-51
58-62mm 105mm UN8-63
Dimensions:
Lamp A BSize mm mm18W 660 55036W 1275 800
Photometric Data:
C0 C90 cd/klm
Typical luminous flux of lamps1 x 18 W = 1,350 Im, 2 x 18 W = 2,700 Im1 x 36 W = 3,350 lm, 2 x 36 W = 6,700 lm
N D F A 1M 236 8 D M N S EProduct Identifier -
NDFA
Entry Size1M- M202M- M251N - 1/2" NPT2N - 3/4" NPT
Wattage118 - 1x18218 - 2x18
136 - 1x36236 - 2x6
Cable Entries0 - No through entryT - Through entriesS - Single through entries
(2 entries on one side)D - Double through entries
(2 entries on one side)
Types of EntryP - PlasticM - Metal
Securing Clips0 - Plastic
S - Stainless SteelExit Sign
0 - NoneE - Exit Sign
Voltage &Frequency
1 - 110V / 60Hz2 - 120V / 60Hz3 - 220V / 50Hz4 - 220V / 60Hz5 - 230V / 50Hz6 - 240V / 50Hz8 - ElectronicBallast - 220-245V /
47-63Hz
Emergency0 - StandardN - Emergency
7/23/2019 4. Haz Area Lighting
18/44
5-18Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Application: For use in locations where aconcentration of flammable gases orvapours may occur as the result ofan abnormal situation
Suitable for DIP locations such asgrain handling facilities or otherareas where hazardous dusts fibres& flyings are present and may
become suspended in theatmosphere or settle on equipmentor ledges
Ideal for walkways, bridges,tunnels, security lighting, roadwaysand process plants where reliablelighting is required for safe operation
For arduous conditions or extremeenvironments
Low profile for use in areas wherevery low mounting heights or otherspace restrictions make installationdifficult
Features: Electronic ballast provides highluminous efficiency, lower energyconsumption and longer service lifeof the lamps
Emergency operation can be setfor 2 hour duration
Central locking system operatedby standard SW13 hex socket keyenables fixture to be opened fromone point of housing
Diffuser fastened by 10 and 20latch points respectively on 18Wand 36W fixtures
Diffuser hinges from either sideand is also designed to act as aconvenient lamp support when opento simplify lamp replacement
Standard Materials: Body ......... Grey FRP (Fibreglassreinforced polyester)
Diffuser .... Mouldedpolycarbonate
Gasket ........... Polyurethane foam Cable entry ........................Brass
Standard Finishes: Body .....................................Grey
Prismatic Diffuser ................ Clear
Options:(Refer to ordering information)
Through wiring ...... Terminal blockat each end of the fixture internallywired (4mm2) to facilitate ease ofconnection
Hanger Mounting ...... Eye Boltsallow for suspension of the fixture byeither chain or steel cable
Pipe Mounting ..Brackets to allowsuspension from a pipe stanchion orwall bracket
Emergency Lighting Pack .....integral power pack to give 2 hoursstandby lighting in the event of apower supply failure
Other entries available uponrequest
Electrical Ratings: 240 V, 50 Hz standard. Othervoltages and frequencies on request
18W, and 36W Temperature rating.
- Exn - T4
Compliances: Australian Standard 2238 ElectricalEquipment for explosive atmospheres............. Non-sparking apparatus.Type of Protection n.
Certificate of Compliance- Aus Ex 3723- PTB 98 ATEX 2208 (excluding Emergency Luminaires)
Australian Standard 1939 Degreesof Protection of electrical equipmentIP66
nLLK
Heavy Duty
FluorescentLighting Fixtures
Non-Sparking, Exn, IIC, IP66/67
Zone 2
Combustible DustZone 21 & 22
7/23/2019 4. Haz Area Lighting
19/44
5-19Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Standard Fixtures
nLLK98018/18 2 x 18W T4 Electronic 13465218021nLLK98036 1 x 36W T4 Electronic 13465136021
nLLK98036/36 2 x 36W T4 Electronic 13465236021nLLK98058 1 x 58W T4 Electronic 13465158021nLLK98058/58 2 x 58W T4 Electronic 13465258021
Emergency Fixtures
nLLK98018/18N 2 x 18W T4 Electronic nLLK1M2188DMN00nLLK98036N 1 x 36W T4 Electronic nLLK1M1368DMN00nLLK98036/36N 2 x 36W T4 Electronic nLLK1M2368DMN00
Type. Lamps Temp Classat 400C
Circuit
Accessories
Type Catalogue No.
Galvanised Eyebolt A2 2 2480 002 000Stainless Steel Ceiling Bracket D92 2 2480 092 000
Pipe Clamps 43mm UN8-43SPPipe Clamps 51mm UN8-51P
Options
Type Catalogue No.
Diffuser c/w EXIT Sign Add E to Cat. No.
Dimensions
Ordering Information
Ordering Information
& Dimensions
CatalogueNo.
7/23/2019 4. Haz Area Lighting
20/44
5-20Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Ordering Information:Cat. No. Lamp Lamp Entry Temperature
Size Type Size RatingAEVBH 22201 200W Incandescent 25mm T3AEVBH 42051 50W HPS 25mm T4AEVBH 42071 70W HPS 25mm T4AEVBH 42101 100W HPS 25mm T4AEVBH 42151 150W HPS 25mm T3
AEVBH 52021 2 x 11W PL Fluorescent 25mm T6AEVBH 82051 50W Mercury Vapour 25mm T3AEVBH 82081 80W Mercury Vapour 25mm T3AEVBH 82101 100W Mercury Vapour 25mm T3AEVBH 82121 125W Mercury Vapour 25mm T3AEVBH 82171 175W Mercury Vapour 25mm T3AEVBH 92171 175W Metal Halide 25mm T3
AEVBH
Large Bulkhead
Luminaire
Application: The AEVBH bulkhead luminaire issuitable for use with HID, fluorescentand incandescent light sources inZone 1 and Zone 21 & 22 hazardouslocations
Ideal for areas with low headroom ormounting height where it allows theuse of energy efficient HID lightsources
For wall mounting in inspection pitsand similar wall mounting applicationwhere the adjustable reflector allowsthe light to be directed
Features: Low profile (180mm) enables it to bemounted in tight spots
Adjustable reflector allows directionof light in specific directions
Available with a variety of lightsources including energy efficientHPS
Reduced maintenance costs whenused with long-life HID light sources
Standard Materials: Body and dome cover ................................... Copper free aluminium
Diffuser ............................................ Heat and impact resistant glass
Guard ........... Stainless steel wire Reflector .............. Stainless steel
Standard Finish: Grey polyurethane
Electrical Rating: 240V 50Hz
200W incandescent 175W mercury vapour 150W high pressure sodium 2 x 11W fluorescent 175W metal halide
Option: Pipe mounting............ Add suffix J Corro free powder polyester finish.....................Information on request
Compliances: AS2380 - Electrical equipment forexplosive atmospheres - Flameproof
enclosure AS2236 - Electrical equipment forexplosive atmospheres - Dustexcluding ignition proof
AS1939 - Degrees of ProtectionIP66
Certificate of Compliance No. Ex647
Dimensions:
Flameproof, Exd, IIC, IP66
Zone 1
Combustible DustZone 21 & 22
7/23/2019 4. Haz Area Lighting
21/44
5-21Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
EVM Hazard Gard
H.I.D. Lighting Fixtures
Integral BallastFactory SealedApplication:EVM Hazard Gard lighting fixturesare used in
Hazardous areas, both indoorsand outdoors where long lamp lifeand low maintenance costs aredesired
Heavy process industries havingenvironments where flammable orexplosive vapours or gases, or
where combustible dusts arepresent
Features: Fixture is factory wired; power isfed through "wireless" connectionblock which serves as a mechanicalseal between entry and ballastcompartment. The result is fast,easy installation with improvedreliability and safety, enabling costeffective installation andmaintenance
Dome and angle reflectors madeof Krydon - will not rust, corrode,
dent, chip or peel High bay Alzak aluminumreflectors are available for mountingheights above 6m.
Uniform attractive appearance inall wattages and mounting styles
Configurated glass reduces glareimproving light distribution
Certified for operation in elevatedambient temperatures of up to 50
oC
Wide range of light sources tomeet specific lighting needs - 80,100, 125, 175, 250 & 400W mercuryvapour (MV); 175, 250 & 400Wmetal halide (MH); 70, 100, 150,
250W, 400W high pressure sodium(HPS)
Four mounting types to suit alllighting layout ... pendant, ceiling,wall bracket, and stanchion
Integral ballasts ... separateballasts are not required
Lowest installed cost
Standard Materials: Mounting modules, cover, ballasthousing, guard, globe ring - copperfree aluminium
Glass ................. Heat and impactresistant, configurated glass
Lamp socket .......... porcelain withstainless steel screw shell Reflectors ... dome and angle .......fibreglass reinforced polyester(Krydon); High Bay, Alzakaluminium
External Hardware stainless steel
Standard Finishes:
Copper free aluminium ........ Grey
polyurethane
Krydon .................... natural white Alzak ............... natural aluminium
Options(Refer to ordering Information)
For Group IIC applications Fuse .......... To protect ballast andcapacitors against line surges
May be ordered with or withoutguard
Instant restrike ballast - enables ahot HPS lamp to immediatelyrestrike after momentary loss of arc
due to voltage fluctuation or powerloss. Available for use with 50-150WLX HPS only
Flameproof, Exd, IIB or IIC, IP66
Zone 1
Combustible DustZone 21 & 22
Electrical Ratings: 240 VAC 50Hz 70 to 400 Watts Alternate operating voltagesavailable, see ordering information
Entry Sizes: 20, 25mm hubs on ceiling, pendantand wall mounted, 1 1/4BSP on Stanchion Mount
Alternate entries available, seeordering information
Compliances: AS2380 Electrical equipment forexplosive atmospheres - Flameproofenclosure
AS2236 - Electrical equipment forexplosive atmospheres. Dust
excluding ignition proof AS1939 - Degrees of ProtectionIP66
Certificate of Compliance No. Ex434
Hazardous
5Area
Lighting
7/23/2019 4. Haz Area Lighting
22/44
5-22Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
E V M A H 1 M 40 B 6 0 0 0 0
Product IdentifierEVMA- Pendant MountEVMB- Wall Mount
EVMC- Ceiling MountEVMJ - Stanchion Mount
Lamp TypeS - HPSH - MVM - MH
Entry Size1 - 20mm / 1/2"
2 - 25mm / 3/4"3 - 32mm / 1"4 - 1 1/4 "
Entry ThreadM - MetricN - 25mm / 3/4"B - BPS
Wattage07 - 70W08 - 80W10 - 100W12 - 125W
15 - 150W17 - 175W25 - 250W40 - 400W
Voltage& Frequency
2 - 120V/60Hz3 - 220V/50Hz4 - 220V/60Hz5 - 230V/50Hz
6 - 240V/50Hz
Special OptionsO - StandardS - Fuse
Special Options0 - Standard1 - Special
Instant Restrike0 - NoneI - IR
Options0 - Standard1 - Offshore Paint
Gas GroupB - Group IIBC - Group IIC
Ordering Information
7/23/2019 4. Haz Area Lighting
23/44
5-23Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Pendant Wall Bracket Ceiling StanchionEntry With Guard With Guard WIth Guard With Guard
Watts Size Cat.No. Cat.No. Cat.No. Cat.No.
Mercury Vapour - High Power Factor
80 20mm EVMA81M08B60000 EVMB81M08B60000 EVMC81M08B6000025mm EVMA82M08B60000 EVMB82M08B60000 EVMC82M08B600001 1/4" BSP EVMJ84B08B60000
100 20mm EVMA82M10B60000 EVMB81M10B60000 EVMC81M10B6000025mm EVMA82M10B60000 EVMB82M10B60000 EVMC82M10B600001 1/4" BSP EVMJ84B10B60000
125 20mm EVMA81M12B60000 EVMB81M12B60000 EVMC81M12B6000025mm EVMA82M12B60000 EVMB82M12B60000 EVMC82M12B600001 1/4" BSP EVMJ84B12B60000
175 20mm EVMA81M17B60000 EVMB81M17B60000 EVMC81M17B6000025mm EVMA82M017B6000 EVMB82M17B60000 EVMC82M17B600001 1/4" BSP EVMJ84B17B60000
250 20mm EVMA81M25B60000 EVMB81M25B60000 EVMC81M25B6000025mm EVMA82M25B60000 EVMB82M25B60000 EVMC82M25B600001 1/4" BSP EVMJ84B25B60000
400 20mm EVMA81M40B60000 EVMB81M40B60000 EVMC81M40B6000025mm EVMA82M40B60000 EVMB82M40B60000 EVMC82M40B600001 1/4" BSP EVMJ84B40B60000
High Pressure Sodium - High Power Factor
70 20mm EVMA41M07B60000 EVMB41M07B60000 EVMC41M07B6000025mm EVMA42M07B60000 EVMB42M07B60000 EVMC42M07B600001 1/4" BSP EVMJ44B07B60000
100 20mm EVMA41M10B60000 EVMB41M10B60000 EVMC41M10B6000025mm EVMA42M10B60000 EVMB42M10B60000 EVMC42M10B600001 1/4" BSP EVMJ44B10B60000
150 20mm EVMA41M15B60000 EVMB41M15B60000 EVMC41M15B6000025mm EVMA42M15B60000 EVMB42M15B60000 EVMC42M15B600001 1/4" BSP EVMJ44B15B60000
250 20mm EVMA41M25B60000 EVMB41M25B60000 EVMC41M25B6000025mm EVMA42M25B60000 EVMB42M25B60000 EVMC42M25B600001 1/4" BSP EVMJ44B25B60000
400 20mm EVMA41M40B60000 EVMB41M40B60000 EVMC41M40B60000
25mm EVMA42M40B60000 EVMB42M40B60000 EVMC42M40B600001 1/4" BSP EVMJ44B40B60000
Metal Halide - High Power Factor Ballast
175 20mm EVMA91M17B60000 EVMB91M17B60000 EVMC91M17B6000025mm EVMA92M17B60000 EVMB92M17B60000 EVMC92M17B600001 1/4" BSP EVMJ94B17B60000
250 20mm EVMA91M25B60000 EVMB91M25B60000 EVMC91M25B6000025mm EVMA92M25B60000 EVMB92M25B60000 EVMC92M25B600001 1/4" BSP EVMJ94B25B60000
400 20mm EVMA91M40B60000 EVMB91M40B60000 EVMC91M40B6000025mm EVMA92M40B60000 EVMB92M40B60000 EVMC92M40B600001 1/4" BSP EVMJ94B40B60000
Fixtures are supplied as standard suitable for 240/50 hz operation.For other voltages please specify required voltage. Ceiling and bracket mounts have 4 hubs;3 are plugged
Ordering Information
7/23/2019 4. Haz Area Lighting
24/44
5-24Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
30 Angle ReflectorCat.No. RA739
Dome ReflectorCat.No. RD739
LampReceptacleCat. No. EV62All sizes
Glass AssemblyWatts Cat. No.Up to 175 EV7302250/400 EV7404
Ceiling MountEntry Cat. No.20mm EV1625mm EV26
GuardWatts Cat. No.Up to 175 EV503250/400 EV5140
Wall MountEntry Cat. No.20mm EV16 + EV8725mm EV26 + EV87
Pendant MountEntry Cat. No.20mm EVMP225mm EVMP3
Stanchion MountEntry Cat. No.1 1/4" BSP EVMJ4
Temperature Classification:
40oc AmbientPower Mercury High Pressure MetalRating (W) Vapour (MV) Sodium (HPS) Halide (MH)70 - T6 -80 T6 - -
100 T4 T4 -125 T4 - -150 - T4 -175 T3 - T4250 T3 T3 T3400 T3 T3 T3
50oc AmbientPower Mercury High Pressure MetalRating (W) Vapour (MV) Sodium (HPS) Halide (MH)70 - T6 -80 T6 - -100 T4 T4 -125 T4 - -150 - T4 -175 T3 - T4250 T3 T3 T3400 T3 T3 T3
High Bay ReflectorCat.No. EV3912
Accessories
7/23/2019 4. Haz Area Lighting
25/44
5-25Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
80, 100, 125, 175, MV70, 100, 150W HPS 250W & 400W
175 MH MV, HPS, MH All
Type A B C D E
EVMA 553 610 499 564 618
EVMBX 635 693 581 646 697
EVMCX 553 610 499 564 618
EVMJ 543 594 573
Accessories
Pendant Mount
Ceiling Mount
Wall Mount
Stanchion Mount
7/23/2019 4. Haz Area Lighting
26/44
5-26Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
EVME Hazard Gard
H.I.D. Lighting Fixtures
Integral Ballast
Application:EVME Hazard Gard lighting fixturesare used in
Hazardous areas, both indoorsand outdoors where long lamp lifeand low maintenance costs are
desired
Heavy process industryenvironments where flammable or
explosive vapours or gases, orcombustible dusts are present
Features:
Indirect cable entry into aseparate Exe termination enclosure
ensures ease of installation
Dome and angle reflectors madeof Krydon - will not rust, corrode,
dent, chip or peel
High bay Alzak aluminiumreflectors are available for mountingheights above 6m
Uniform attractive appearance in
all wattages and mounting styles
Configurated glass reduces glareimproving light distribution
Certified for operation in elevatedambient temperatures of up to 50
oC
Wide range of light sources tomeet specific lighting needs - 80,
100, 125, 175, 250 & 400W mercury
vapour (MV); 175, 250 & 400Wmetal halide (MH); 70, 100, 150,
250W, 400W high pressure sodium(HPS)
Standard ceiling mount luminaires
can be adapted for wall, pendant orstanchion mount by using brackets
(order brackets seperatetly)
Integral ballasts ... separateballasts are not required
Lowest installed cost
Standard Materials:
Mounting modules, cover, ballasthousing, guard, globe ring - copper
free aluminium
Glass ................. Heat and impactresistant, configurated glass
Lamp socket .......... porcelain with
stainless steel screw shell
Reflectors ... dome and angle .......fibreglass reinforced polyester
(Krydon); High Bay, Alzak
aluminium
External Hardware stainless steel
Standard Finishes:
Copper free aluminium ........ Greypolyurethane
Krydon .................... natural white Alzak ............... natural aluminium
Options(Refer to ordering Information)
For Group IIC applications Fuse .......... To protect ballast andcapacitors against line surges
Instant restrike ballast - enables ahot HPS lamp to immediately
restrike after momentary loss of arcdue to voltage fluctuation or power
loss. Available for use with 50-150W
LX HPS only
Alternate entries available -please consult factory
Electrical Ratings:
240 VAC 50Hz 70 to 400 Watts Alternate operating voltagesavailable, see ordering information
Entry Sizes:
20, 25mm hubs on ceiling, pendantand wall mounted, 1 1/4
BSP on Stanchion Mount
Alternate entries available, seeordering information
Compliances:
EN50014EN50018EN50019
EN60529
EN60598
AS/NZS: 60079.0.2000AS/NZS: 60079.1.2000AS/NZS: 60079.7.2002
Certificate of Compliance No.PTB ATEX1056
Aus EX Pending
Ambient Temperature-50
0
to 550
C
Flameproof, Exde, IIB or IIC, IP66
Zone 1
Combustible DustZone 21 & 22
7/23/2019 4. Haz Area Lighting
27/44
5-27Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
E V M E H 1 M 40 B 6 0 0 0 0
Ordering Information
Product Identifiers
Lamp TypeS - HPSH - MVM - MH
Entry Size1 - 20mm / 1/2"
2 - 25mm / 3/4"3 - 32mm / 1"4 - 1 1/4 "
Entry ThreadM - MetricN - 25mm / 3/4"B - BPS
Wattage07 - 70W08 - 80W10 - 100W12 - 125W
15 - 150W17 - 175W25 - 250W40 - 400W
Voltage& Frequency
2 - 120V/60Hz3 - 220V/50Hz4 - 220V/60Hz5 - 230V/50Hz
6 - 240V/50Hz
Special OptionsO - StandardS - Fuse
Special Options0 - Standard1 - Special
Instant Restrike0 - NoneI - IR
Options0 - Standard1 - Offshore Paint
Gas GroupB - Group IIBC - Group IIC
7/23/2019 4. Haz Area Lighting
28/44
5-28Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Ordering Information
Mercury Vapour (M/V)
Wattage T Rating Cat No.
80W T6 EVMEH1M08B60000100W T5 EVMEH1M10B60000125W T4 EVMEH1M12B60000175W T4 EVMEH1M17B60000250W T3 EVMEH1M25B60000400W T3 EVMEH1M40B60000
High Pressure Sodium (HPS)
Wattage T Rating Cat No.
70W T6 EVMES1M07B60000100W T4 EVMES1M10B60000150W T4 EVMES1M15B60000250W T3 EVMES1M25B60000400W T3 EVMES1M40B60000
High Metal Halide (MH)
Wattage T Rating Cat No.
70W T6 EVMEM1M07B60000100W T4 EVMEM1M10B60000150W T4 EVMEM1M15B60000175W T4 EVMEM1M17B60000250W T3 EVMEM1M25B60000400W T3 EVMEM1M40B60000
* Please refer to table for other possible configurations
Mounting Brackets (order seperately)Pendant Mount Cat No.
M20 EVMEPM1M25 EVMEPM21/2" NPT Clearance Hole EVMEPN13/4" NPT Clearance Hole EVMEPN2
Wall Mount Cat No.
M20 Thread EVMEWM1M25 Thread EVMEWM2
Stanchion Mount Cat No.
2" Slipfitter Pipe EVMEJ1 1/4" BSP Thread EVMEJB41 1/2" NPT Thread EVMEJN5
7/23/2019 4. Haz Area Lighting
29/44
5-29Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Accessories
Stanchion BracketCat No. EVMEJ
Wall BracketCat No. EVMEW
30 Angle ReflectorCat.No. RA739
Dome ReflectorCat.No. RD739
High Bay ReflectorCat.No. EV3912
Glass AssemblyWatts Cat. No.
Up to 175 EV7302250/400 EV7404
GuardWatts Cat. No.Up to 175 EV503250/400 EV5140
Lamp HolderWatts Cat. No.
Up to 125 EVMVS62600-SA150 to 400 EVMVS12850-SA
Pendant BracketCat No. EVMEP
7/23/2019 4. Haz Area Lighting
30/44
5-30Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Dimensions
Pendant Mount
Ceiling Mount
Wall Mount
Stanchion Mount
7/23/2019 4. Haz Area Lighting
31/44
5-31Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Fixture With Globe, Dome Reflectorand Without Guard
NOTE: Photometric data was developed using a 100 wattdiffuse mercury vapour lamp (4200 lumens). For otherdiffuse lamps, use the following conversion factors(multipliers): 175W MV - 2.05; 70W MH - 1.33;100W MH - 1.85; 175W MH - 3.3.Multipliers are for use with candela curve only.Luminaire Spacing ratio is 1.30.
Coefficient of UtilisationEffective Floor Cavity Reflectance 20%
% Reflectance Room Cavity RatioEff.Ceil. Wall 1 2 3 4 5
50 .694 .584 .503 .439 .38680 30 .644 .516 .428 .361 .31110 .600 .459 .369 .302 .253
50 .660 .556 .479 .418 .36870 30 .615 .493 .410 .347 .297
10 .572 .441 .355 .291 .244
50 .596 .501 .432 .377 .33450 30 .559 .450 .375 .317 .274
10 .526 .405 .328 .270 .227
50 .538 .451 .389 .339 .30230 30 .509 .410 .342 .290 .250
10 .481 .373 .302 .249 .210
50 .485 .405 .349 .305 .27110 30 .461 .371 .310 .263 .223
10 .439 .341 .277 .228 .1930 0 .410 .313 .251 .204 .171
% Reflectance Room Cavity RatioEff.Ceil. Wall 6 7 8 9 10
50 .347 .312 .282 .259 .23080 30 .273 .241 .214 .192 .166
10 .220 .192 .165 .147 .125
50 .331 .298 .270 .248 .22070 30 .262 .231 .206 .185 .162
10 .211 .184 .160 .143 .121
50 .300 .272 .246 .227 .20350 30 .241 .212 .190 .172 .150
10 .197 .171 .149 .134 .113
50 .272 .245 .225 .207 .18530 30 .222 .196 .175 .158 .138
10 .183 .158 .139 .124 .105
50 .246 .224 .203 .188 .16910 30 .202 .180 .160 .146 .127
10 .168 .147 .129 .115 .096
0 0 .148 .128 .111 .099 .082
NOTE: Photometric data was developed using a 100 wattdiffuse mercury vapour lamp (4200 lumens). For otherdiffuse lamps, use the following conversion factors(multipliers): 175W MV - 2.05; 70W MH - 1.33;100W MH - 1.85; 175W MH - 3.3.Multipliers are for use with candela curve only.Luminaire spacing ratio is 1.25.
Lamp: 100W mercury vapour - (MV)Total bare lamp lumens: 4200
Coefficient of UtilisationEffective Floor Cavity Reflectance 20%
% Reflectance Room Cavity RatioEff.Ceil. Wall 1 2 3 4 5
50 .715 .637 .570 .509 .45880 30 .688 .596 .521 .455 .401
10 .655 .562 .483 .413 .359
50 .699 .624 .560 .500 .44870 30 .675 .586 .514 .450 .396
10 .652 .556 .478 .410 .356
50 .668 .598 .539 .481 .43450 30 .648 .568 .500 .438 .388
10 .631 .540 .468 .404 .353
50 .640 .576 .519 .465 .42030 30 .624 .550 .487 .428 .379
10 .609 .527 .459 .398 .348
50 .615 .554 .502 .450 .40710 30 .602 .553 .474 .418 .372
10 .589 .514 .450 .391 .3430 0 .575 .500 .436 .377 .329
% Reflectance Room Cavity RatioEff.Ceil. Wall 6 7 8 9 10
50 .414 .375 .340 .313 .27580 30 .358 .319 .286 .259 .222
10 .318 .282 .247 .222 .187
50 .407 .369 .335 .308 .27170 30 .354 .315 .283 .256 .222
10 .315 .278 .246 .221 .187
50 .394 .358 .325 .229 .26450 30 .347 .309 .278 .252 .217
10 .312 .275 .244 .219 .185
50 .383 .346 .316 .292 .25730 30 .340 .304 .273 .248 .214
10 .308 .272 .242 .217 .183
50 .371 .338 .307 .284 .25110 30 .333 .299 .268 .244 .210
10 .304 .269 .240 .215 .181
0 0 .292 .257 .227 .204 .170
Lamp: 100W mercury vapour - (MV)Total bare lamp lumens: 4200
Fixture With Globeand Without Guard
Hazardous
5Area
Lighting
7/23/2019 4. Haz Area Lighting
32/44
5-32Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Isolux Chart: Fixture With Globe and300 Angle Reflector, Without Guard
Illumination in footcandles on work plane 3m below lightcentre. Multiply by factor shown to convert to other
mounting heightsHeight (m) Factor Height (m) Factor
1.8 2.78 2.7 1.232.1 2.04 3.3 0.832.4 1.56 3.7 0.70
Fixture With Globeand Without Guard
Lamp: 150W high pressure sodium (HPS)
Total bare lamp lumens: 16,000
Coefficient of UtilisationEffective Floor Cavity Reflectance 20%
% Reflectance Room Cavity RatioEff.Ceil. Wall 1 2 3 4 5
50 .695 .579 .494 .410 .38280 30 .644 .509 .417 .326 .305
10 .599 .450 .356 .262 .246
50 .659 .549 .469 .387 .36370 30 .613 .484 .397 .311 .291
10 .570 .431 .341 .251 .236
50 .592 .491 .419 .344 .23750 30 .555 .439 .360 .279 .265
10 .522 .393 .312 .229 .218
50 .531 .438 .373 .304 .29230 30 .502 .396 .325 .250 .240
10 .474 .358 .284 .207 .200
50 .476 .390 .331 .267 .26010 30 .451 .355 .291 .222 .217
10 .429 .325 .257 .184 .1810 0 .399 .295 .230 .159 .159
% Reflectance Room Cavity RatioEff.Ceil. Wall 6 7 8 9 10
50 .342 .306 .278 .265 .23380 30 .266 .234 .209 .198 .168
10 .212 .184 .160 .153 .127
50 .324 .292 .265 .253 .22270 30 .254 .223 .201 .191 .163
10 .202 .176 .155 .149 .123
50 .292 .263 .240 .231 .20350 30 .232 .203 .184 .177 .150
10 .187 .162 .143 .139 .114
50 .262 .236 .218 .210 .18530 30 .211 .186 .167 .162 .138
10 .172 .148 .132 .129 .105
50 .234 .213 .195 .191 .16710 30 .190 .169 .152 .149 .125
10 .156 .135 .121 .118 .096
0 0 0 .135 .116 .103 .081
NOTE: Photometric data was developed using a 150 wattclear high pressure sodium lamp (16,000 lumens). Forother clear lamps, use the following conversion factors(multipliers): 50W HPS - .25; 70W HPS - .40;100W HPS - .59.Multipliers are for use with candela curve only.Luminaire spacing ratio is 0.80.
Lamp: 100W diffuse mercury vapour (MV)
Total bare lamp lumens: 4,200
NOTE: Photometric data was developed using a 100 wattdiffuse mercury vapour lamp (4200 lumens). For otherdiffuse lamps, use the following conversion factors(multipliers): 175W MV - 2.05; 70W MH - 1.33;100W MH - 1.85; 175W MH - 3.3.
7/23/2019 4. Haz Area Lighting
33/44
5-33Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Lamp: 150W high pressure sodium - (HPS)Total bare lamp lumens: 16,000
Fixture With Globe, Hi-Bay Reflectorand Without Guard
Fixture With Globe, Dome Reflectorand Without Guard
Coefficient of UtilisationEffective Floor Cavity Reflectance 20%
% Reflectance Room Cavity RatioEff.Ceil. Wall 1 2 3 4 5
50 .716 .637 .568 .507 .45580 30 .689 .596 .519 .452 .39810 .666 .561 .480 .410 .355
50 .700 .624 .559 .498 .44670 30 .675 .585 .512 .447 .393
10 .653 .555 .476 .407 .353
50 .668 .598 .538 .479 .43250 30 .648 .567 .498 .435 .385
10 .631 .539 .466 .400 .349
50 .640 .575 .518 .463 .41730 30 .625 .549 .485 .425 .376
10 .610 .526 .457 .394 .344
50 .615 .554 .500 .447 .40410 30 .602 .532 .472 .415 .369
10 .590 .513 .448 .388 .3390 0 .575 .498 .434 .373 .326
% Reflectance Room Cavity RatioEff.Ceil. Wall 6 7 8 9 10
50 .413 .373 .339 .312 .27580 30 .355 .318 .285 .258 .222
10 .316 .280 .246 .221 .187
50 .405 .368 .334 .308 .27170 30 .352 .314 .283 .256 .222
10 .312 .277 .245 .221 .187
50 .392 .356 .324 .299 .26450 30 .345 .307 .277 .252 .217
10 .309 .274 .243 .219 .185
50 .380 .345 .316 .291 .257
30 30 .338 .303 .272 .247 .21410 .306 .270 .241 .217 .183
50 .369 .337 .307 .283 .25110 30 .331 .298 .267 .244 .210
10 .301 .267 .238 .215 .181
0 0 .292 .257 .227 .204 .170
NOTE: Photometric data was developed using a 150 wattclear high pressure sodium lamp (16000 lumens). For otherclear lamps, use the following conversion factors(multipliers): 50W HPS - .25; 70W HPS - .40;100W HPS - .59.Multipliers are for use with candela curve only.Luminaire spacing ratio is 1.00.
Coefficient of UtilisationEffective Floor Cavity Reflectance 20%
% Reflectance Room Cavity RatioEff.Ceil. Wall 1 2 3 4 5
50 .688 .618 .573 .531 .49480 30 .651 .592 .542 .495 .455
10 .636 .569 .517 .468 .427
50 .655 .608 .566 .525 .48770 30 .639 .583 .536 .491 .452
10 .525 .564 .513 .464 .425
50 .629 .587 .550 .511 .47650 30 .616 .568 .525 .482 .446
10 .606 .550 .505 .459 .422
50 .606 .569 .535 .498 .46630 30 .597 .554 .514 .474 .438
10 .588 .539 .497 .454 .418
50 .586 .533 .522 .487 .45710 30 .578 .539 .504 .466 .433
10 .570 .528 .489 .449 .4130 0 .560 .517 .479 .439 .404
% Reflectance Room Cavity RatioEff.Ceil. Wall 6 7 8 9 10
50 .460 .427 .396 .369 .32880 30 .420 .388 .358 .330 .288
10 .394 .361 .330 .303 .262
50 .455 .423 .392 .366 .32570 30 .418 .385 .356 .328 .288
10 .391 .359 .329 .303 .262
50 .444 .414 .385 .360 .32050 30 .412 .380 .352 .325 .285
10 .388 .357 .328 .301 .261
50 .436 .406 .379 .354 .315
30 30 .407 .377 .348 .322 .28210 .385 .354 .326 .300 .259
50 .428 .400 .373 .348 .31110 30 .402 .373 .345 .319 .280
10 .382 .352 .324 .298 .258
0 .373 .343 .315 .290 .249
NOTE: Photometric data was developed using a 150 wattclear high pressure sodium lamp (16000 lumens). Forother clear lamps, use the following conversion factors(multipliers): 50W HPS - .25; 70W HPS - .40;100W HPS - .59.Multipliers are for use with candela curve only.Luminaire spacing ratio is 1.00.
Lamp: 150Whigh pressure sodium - (HPS)
Total bare lamp lumens: 16,000
7/23/2019 4. Haz Area Lighting
34/44
5-34Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Electrical Rating:
240V 50Hz 70 to 400W P.F. 0.9
Compliances: AS2380 Electrical equipment forexplosive atmospheres - Non-Sparking Equipment, & DustExcluding Ignition Proof
AS 1939 ...Degrees of protectionIP66
EN50021:1999 Certificate of Compliance No.
- Ex426
- PTB00 ATEX 2215
Dimensions: See Pages 6-8 to 6-9
Photometric Data: See Pages 6-10 to 6-13
Accessories: See Page 5-38
NVMV Champ
HID Lighting Fixtures
Integral Ballast
Application: Used in locations where aconcentration of hazardous gasesliquids or vapours may occur forshort periods of time at infrequentintervals
Used in hazardous locations wherecombustible dusts, fibres or flyingsmay be present
Used where maintenance access
is difficult and extended periodsbetween relamping is required
Ideal for processing plants, wasteand sewage treatment facilitiessecurity lighting, roadways, garages& other heavy industrial applications
Used where space is limited andhigh levels of lighting are required
Features:All Units:
Several mounting arrangements:PendantCeiling for flush to surface mountingWall bracket-through feedStanchion - 25 angle
Integral long-life ballast Choice of light source - mercuryvapour (MV), high pressure sodium(HPS) or metal halide
Operating ambient temperaturebetween minus 45C and 55
Attractive gray polyurethane paintfinish
Configured glass and prismaticrefractors reduce glare and improvelight distribution
Recessed hubs Restricted breathing design givesimproved T Rating allowing use ofhigher lumen output fixtures
Special Exn terminals to ensurepositive connection to circuit wiring
Standard Materials: Ballast housings and mountings -copper free aluminium(less than 0.4 of 1%)
Guards - copper free aluminium orstainless steel wire
Exterior hardware - stainless steel Globes - configurated glass
Reflectors - dome or angle whiteKrydon fibreglass - reinforcedpolyester material
Reflector lens assy - Alzakaluminium reflector, tempered glasslens
Ceiling mount with dome reflector
Non-Sparking, ExnR, IIC, IP66
Zone 2
Combustible DustZone 21 & 22
Standard Finishes:
Aluminium ballast housings,
mountings and aluminium guards............ grey polyurethane paint
Stainless steel wire guards............................ natural
Reflectors .......................... natural
Options:(Refer to ordering information)
Corro-free powder polyestercoating, information available onrequest
Quartz auxiliary lamp to providelight during the period required forHID lamps to restrike followingresumption of power after a powerfailure - Large body fixtures only
Instant restrike ballast - enables ahot HPS lamp to immediately restrikeafter a momentary loss of arc due tovoltage fluctuation or power outage. Ithas no effect on the warm-up periodof cold lamps. Available for use with50-150W HPS LX only
Large body for improved T Ratingon 250 Watt fixtures
For application subject to extremethermal shock, Tuff-skin coated G34and G251 glasses are available
Non-standard supply voltage andfrequency, consult factory Fuse - to protect against abnormalline conditions and provide additionalcircuit protection
Other entries available upon request
7/23/2019 4. Haz Area Lighting
35/44
5-35Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Ordering Information
NVMV S 1 M C 40 6 P I 0 0
Product GroupNVMV- Champ
Lamp TypeS - HPSH - MVM - MH
Entry Size1 - 20mm / 1/2"
2 - 25mm / 3/4"3 - 32mm / 1"4 - 1 1/4"5 - 1 1/2"
Entry ThreadM - MetricN - NPTB - BSP
Mounting
C - CeilingW - WallJ - Stanchion
Voltage& Frequency
2 - 120V / 60Hz3 - 220V / 50Hz4 - 220V / 60Hz5 - 230V / 50Hz
6 - 240V / 50Hz
Special Options0 - StandardS - Fuse
Guard0 - Without GuardP - GuardR - RD4A
Instant Restrike0 - None / Small BodyI - IRL - Large Body
Options0 - Standard1 - Offshore PaintR - Red Body
Wattage07 - 70W08 - 80W10 - 100W12 - 125W15 - 150W17 - 175W25 - 250W40 - 400W
Hazardous
5Area
Lighting
7/23/2019 4. Haz Area Lighting
36/44
5-36Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Ordering Information
Mercury Vapour (M/V) 240V/50Hz*High power factor reactor ballast (.9)
Entry Lamp With Glass and Guard With Reflector Lens Assy.Size Watts Cat. No. Cat. No.
Ceiling/Pendant Mount20mm 80 NVMVH1MC086P000 -25mm 80 NVMVH2MC086P000 -20mm 100 NVMVH1MC106P000 -25mm 100 NVMVH2MC106P000 -20mm 125 NVMVH1MC126P000 -25mm 125 NVMVH2MC126P000 -20mm 175 NVMVH1MC176P00025mm 175 NVMVH2MC176P00020mm 250 NVMVH1MC256P000 NVMVH1MC256RL0025mm 250 NVMVH2MC256P000 NVMVH2MC256RL0020mm 400 NVMVH1MC406PL00 NVMVH1MC406RL0025mm 400 NVMVH2MC406PL00 NVMVH2MC406RL00
Wall Mount20mm 80 NVMVH1MW086P000 -25mm 80 NVMVH2MW086P000 -20mm 100 NVMVH1MW106P000 -25mm 100 NVMVH2MW106P000 -20mm 125 NVMVH1MW126P000 -25mm 125 NVMVH2MW126P000 -20mm 175 NVMVH1MW176P000 -25mm 175 NVMVH1MW176P000 -20mm 250 NVMVH1MW256P000 NVMVH1MW256RL0025mm 250 NVMVH2MW256P000 NVMVH2MW256RL0020mm 400 NVMVH1MW406PL00 NVMVH1MW406RL0025mm 400 NVMVH2MW406PL00 NVMVH2MW406RL00
Stanchion Mount1 1/4" BSP 80 NVMVH4BJ086P000 -1 1/4" BSP 100 NVMVH4BJ106P000 -1 1/4" BSP 125 NVMVH4BJ126P000 -1 1/4" BSP 175 NVMVH4BJ176P000 -1 1/4" BSP 250 NVMVH4BJ256P000 -1 1/4" BSP 400 NVMVH4BJ406PL00 -
Large body ceiling mount withRD4A reflector lens assembly
7/23/2019 4. Haz Area Lighting
37/44
5-37Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Ordering Information
High Pressure Sodium (HPS) 240V/50Hz*High power factor reactor ballast (.9) with solid state ignitor
With Glass With ReflectorEntry Lamp And Guard & Lens Assy.Size Watts Cat. No. Cat. No.Ceiling / Pendant Mount20mm 70 NVMVS1MC076P000 -25mm 70 NVMVS2MC076P000 -20mm 100 NVMVS1MC106P000 -25mm 100 NVMVS1MC106P000 -20mm 150 NVMVS1MC156P000 -25mm 150 NVMVS2MC156P000 -20mm 250 NVMVS1MC256P000 NVMVS1MC256RL00
25mm 250 NHMVS2MC256P000 NVMVS2MC256RL0020mm 400 NVMVS1MC406PL00 NVMVS1MC406RL0025mm 400 NVMVS2MC406PL00 NVMVS2MC406RL00Wall Mount20mm 70 NVMVS1MW076P000 -25mm 70 NVMVS2MW076P000 -20mm 100 NVMVS1MW106P000 -25mm 100 NVMVS2MW106P000 -20mm 150 NVMVS1MW156P000 -25mm 150 NVMVS2MW156P000 -20mm 250 NVMVS1MW256P000 NVMVS1MW256RL0025mm 250 NVMVS2MW256P000 NVMVS2MW256RL0020mm 400 NVMVS1MW406PL00 NVMVS1MW406RL0025mm 400 NVMVS2MW406PL00 NVMVS2MW406RL00
Stanchion Mount1 1/4" BSP 70 NVMVS4BJ076P000 -1 1/4" BSP 100 NVMVS4BJ106P000 -1 1/4" BSP 150 NVMVS4BJ156P000 -1 1/4" BSP 250 NVMVS4BJ256P000 NVMVS4BJ256RL001 1/4" BSP 400 NVMVS4BJ406PL00 NVMVS4BJ406RL00
Metal Halide (MH)High power factor reactor ballast (.9) with solid state ignitor
Ceiling / Pendant Mount20mm 175 NVMVM1MC176P000 -
25mm 175 NVMVM2MC176P000 -20mm 250 NVMVM2MC256P000 NVMVM1MC256RL0025mm 250 NVMVM2MC256P000 NVMVM1MC256RL0020mm 400 NVMVM2MC406PL00 NVMVM1MC406RL0025mm 400 NVMVM2MC406PL00 NVMVM1MC406RL00Wall Mount20mm 175 NVMVM1MW176P000 -25mm 175 NVMVM1MW176P000 -20mm 250 NVMVM1MW256P000 NVMVM1MW256RL0025mm 250 NVMVM1MW256P000 NVMVM1MW256RL0020mm 400 NVMVM1MW406PL00 NVMVM1MW406RL0025mm 400 NVMVM1MW406PL00 NVMVM1MW406RL00Stanchion Mount1 1/4" BSP 175 NVMVM4BJ176P000 -
1 1/4" BSP 250 NVMVM4BJ176P000 NVMVM4BJ256RL001 1/4" BSP 400 NVMVM4BJ176PL00 NVMVM4BJ406RL00
Please refer to page 5-30 for other configurations
7/23/2019 4. Haz Area Lighting
38/44
5-38Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Accessories
GLASSES
ConfiguredLamp Fixture GlassSize Cat. No. Type70-250W G34 Heat
(No Guard) Resistant
G251 Heat(With Guard) Resistant
400W G303 HeatResistant
REFLECTORSLampSize Cat. No. Type
70-250W RD70 DomeRA70 30 Angle
400W RD739 Dome(Large Body) RA739 30 Angle
REFLECTOR/LENSLampSize Cat. No.400W RD4A
GUARDSLamp Suits Glass Guard.Size Cat No. Cat No.70-250W G251 P22250W (Large Body) G303 P33400W G303 P33
Temperature Classification:
Power Mercury High Pressure Metal
Rating (W) Vapour (MV) Sodium (HPS) Halide (MH)G34 G303 G251 G34 G303 G251 G34 G303 G251
70 - - T5 T5 - -
80 T4 T4 - - - -
100 T4 T4 T4 T3 - -
125 T4 T3 - - - -
150 - - T4 T3 - -
175 (small body) T3 T3 - - T3 T3
175 (large body) T4
250 (small body) T3 T2 T3 T2 T3 T2
250 (large body) T3 T3 T3
400 T2 T3 T2
400 (using sealed T3 T4 T3
reflector/glass RD4A)
Note: Light fixtures up to 250W use small body.
400W fixtures use large body
250W can be supplied in large body to give improved T rating - Please refer to table o
7/23/2019 4. Haz Area Lighting
39/44
5-39Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
NFMV
Industrial
FloodlightLuminaires
Application:NFMV floodlights are suitable for use in:
Outdoor locations such as thosefound in process plants,manufacturing plants, loading andstorage areas, petrochemical, wasteror sewerage treatment plants
Features: Enclosed and gasketed forwet locations Choice of HID light sourcesincluding HPS; 70, 100, 150,250, & 400 MV; 175, 250 &400 MH;175, 250 & 400
Versatile yoke mountingbracket simplifies installation
Slipfitter adaptoravailable for 2 pole topmounting
Door frame is hingedand has captivefastening screws forease of relamping
Silicone rubbergaskets are standard,ensuring long life andreliable environmentalsealing even underadverse conditions
Die cast aluminiumexterior components areepoxy powder coated forsuperior corrosion resistance
Corrosion resistant stainlesssteel external hardware
Standard Materials: Housing and door frame............................die cast aluminium
Lens ... tempered heat and impactresistant glass Gasket .............. extruded silicone Exterior hardware .......... stainlesssteel
Standard Finishes: Grey epoxy powder coated
Electrical Rating: 240 50Hz 70 to 400 watts Other voltages and frequenciesavailable on request
Compliances: AS2380.9 Exn AS 2236... 1994 DIP EN50021 Certificate of Compliance No.
- Aus Ex 3562- PTB 00 Atex 2214
Ordering Information:Cat No.
Mercury Vapour
NFMVH1MY4060000 T3 400W MV
NFMVH1MY2560000 T3 250W MV
NFMVH1MY1760000 T4 175W MV
High Pressure Sodium
NFMVS1MY4060000 T3 400W HPS
NFMVS1MY2560000 T4 250W HPS
NFMVS1MY1560000 T5 150W HPS
NFMVS1MY1060000 T5 100W HPS
NFMVS1MY0760000 T6 70W HPS
Metal Halide
NFMVM1MY4060000 T3 400W MH
NFMVM1MY2560000 T4 250W MH
NFMVM1MY1760000 T4 175W MH
Mounting Accessory
Slipfitter
SFA6 - M20
SFA6 / 2M - M25
NFMV showing SFA6
slipfitter adaptor and gland
(order separately)
Non-Sparking, Exn R, IIC, IP66
Zone 2
Combustible DustZone 21 & 22
7/23/2019 4. Haz Area Lighting
40/44
5-40Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
NFMV S 1 M Y 40 6 0 0 0 0
Product GroupNFMV - Floodlight
Lamp TypeS - HPSH - MVM - MH
Entry Size1 - 20mm / 1/2"2 - 25mm / 3/4"
3 - 32mm / 1"4 - 1 1/4"5 - 1 1/2"
Entry ThreadM - MetricN - NPTB - BSP
Mounting
C - CeilingW - WallJ - Stanchion
Voltage& Frequency
1 - 110V / 60Hz2 - 120V / 60Hz3 - 220V / 50Hz4 - 220V / 60Hz
5 - 230V / 50Hz6 - 240V / 50Hz7 - 227V / 60Hz
Special Options0 - StandardS - Fused
0 - NFMV
Instant Restrike0 - NoneI - IR
Options0 - Standard1 - Offshore PaintR - Red Body
Wattage07 - 70W08 - 80W10 - 100W12 - 125W15 - 150W17 - 175W25 - 250W40 - 400W
Ordering Information
7/23/2019 4. Haz Area Lighting
41/44
5-41Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Dimensions (mm)
Lamp: 400W high pressure sodium (HPS)Total bare lamp lumens:50,000
For 150 watt HPS, multiply lux by 0.32. For 250 watthigh pressure sodium, multiply lux values by 0.6
Lamp: 400W metal halide (M / H)Total bare lamp lumens: 34,000
For 250 watt clear metal halide,multiply lux values by 0.6
175
530
45065
390
120
2Holes15
20mm Entry
430
660
MountingDe
tails
Isolux Values at Various Mounting Heights(Lux values for both charts)
MountingHeight A B C D E
5m 86.0 43.0 21.52 8.61 4.30
6m 18.42 24.75 11.84 5.38 2.47
7m 31.20 15.06 7.53 3.23 1.51
9m 21.52 10.76 5.38 2.15 1.08
11m 16.14 7.53 4.30 1.61 0.75
12m 11.84 6.46 3.23 1.18 0.65
RatioofD
istanceto
Mountin
gHeight
Ratio of Distance to Mounting Feet Ratio of Distance to Mounting Feet
Fixtures located at 00, 00
Aiming angle at 450
Fixture aiming angle 300 past verticalthrough 600 before vertical
00 = 2.9 300 = 2.5 450 = 2.5
EPA Data - Aiming Angle
10
Photometric Data
& Dimensions
RatioofD
istanceto
Mountin
gHeight
7/23/2019 4. Haz Area Lighting
42/44
5-42Crouse-Hinds
Hazardous
5Area
Lighting
May 2003 Copyright 2003 Cooper Industries, Inc
Application:The FSFB flashing beacon can beused as:
as an obstruction marker as a visual alarm signal in areas which may be hazardousdue to the presence of flammableliquids, gases or vapours,and dusts
Features: Solid state beacon means no movingparts to wear out or fail Flametight threaded joints O-ring gaskets for weatherproofing Lightweight, copper free aluminiumprincipal parts
Easy to assemble
Standard Materials: Body ..... Copper free cast aluminium Dome ................. Heat and impactresistant glass
Beacon ......Solid state strobe light
Standard Finish:
Grey polyurethaneOptions: Cast aluminium guard.........................Cat. No.EV505
Special paint or protective finishes.............................. specify
Other colours: Clear, Green, Blue,Amber. Add C, G, B or A to Cat. No.when ordering
Pendant entry ..... specify size &thread form
Compliances:
AS2480 Electrical equipment forexplosive atmospheres - Flameproofenclosure
AS2236 - Electrical equipment forexplosive atmospheres. Dust excludingIgnition - proof
AS1939 - Degrees of ProtectionIP65
Certificate of Compliance No. Ex491
Ordering Information: FSFB201 / Voltage / ColourExample FSFB20124R = 24 Volt red
Technical Data:
Supply 24V DC240V AC
Flash Rate 60 FPM Light Output 2.25 Joules per flash Conduit Entries 2 x 20mm
(1 Plugged)
FSFB 301
Flashing
Beacon
Dimensions:
Flameproof, Exd, IIC, IP66
Zone 1
Combustible DustZone 21 & 22
7/23/2019 4. Haz Area Lighting
43/44
5-43Crouse-Hinds
May 2003 Copyright 2003 Cooper Industries, Inc
Hazardous
5Area
Lighting
Application:The FRFB rotating beacon can beused as:
as an obstruction marker as a visual alarm signal in areas which may be hazardousdue to the presence of flammableliquids, gases or vapours, and dusts
Features: Flametight threaded joints O-ring gaskets for weatherproofing Lightweight, copper free aluminiumprincipal parts
Easy to assemble
Standard Materials: Body .. Copper free cast aluminium Dome ................. Heat and impactresistant glass - red
Beacon ..........................Lamp size70 W quartz Halogen / 24V DC55W quartz Halogen / 12V DC25W incandescent / 240V ACAdd 12, 24 or 240 to Cat. No. when
orderingStandard Finish: Grey polyurethane
Options: Cast aluminium guard.........................Cat. No. EV505
Special paint or protective finishes.............................. specify
Other dome colours: Clear, Green,Blue, Amber. Add C, G, B or A to Cat.No. when ordering
Pendant entry ..... specify size &thread form
Compliances: AS2480 - Electrical equipment forexplosive atmospheres - Flameproofenclosure
AS2236 - Electrical equipment forexplosive atmospheres. Dust excludingIgnition - proof AS1939 - Degrees of Protection IP65 Certificate of Compliance No. Ex491
Technical Data: Supply 12/24V DC
240V 50HZ AC
Flash Rate 150 RPM Conduit Entries 2 x 20mm(1 Plugged)
Ordering Information: FRFB301 / Voltage / ColourExample FRFB30124R = 24 Volt red
FRFB 301
Rotating
Beacon
Dimensions:
Flameproof, Exd, IIC, IP66
Zone 1
Combustible DustZone 21 & 22
7/23/2019 4. Haz Area Lighting
44/44
5-44Crouse-Hinds
Hazardous
5Area
Lighting