Page 1: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

INTERNAL

www.huawei.com

Huawei OptiX OSN Equipment Command Line Introduction

Page 2: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 2HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

This course assumes that you know the following:

Fundamentals of communication networks

SDH principle and networking

Hardware of Huawei OptiX OSN equipment

Page 3: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 3HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Tips

This course explains Chapter 1 and Chapter 2 in

the OptiX OSN 1500/2500/3500/7500/9500 Co

mmand Line Introduction.

This course focuses on Chapter 2 “Command Li

ne Configuration File” in the OptiX OSN

1500/2500/3500/7500/9500 Command Line Intr

oduction.

Page 4: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 4HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

References

OptiX OSN 1500/2500/3500 Intelligent Optical Tr

ansmission System Hardware Description

OptiX OSN 7500 Intelligent Optical Switching Sy

stem Hardware Description

OptiX OSN 9500 Intelligent Optical Switching Sy

stem Hardware Description

OptiX NG-SDH Command Line Introduction

Page 5: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 5HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

After completing this presentation, you should be able to:

Maintain and commission the equipment by using command lines.

Develop and issue a command line batch file for NE configuration.

Run common commands.

Page 6: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 6HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Chapter 1 Overview of Command LinesChapter 1 Overview of Command Lines

Chapter 2 Developing a Batch File

Chapter 3 Common Commands

Page 7: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 7HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Here, a command line is a man-machine command issued to Huawei OptiX equipment.

Like the T2000, a command line helps greatly to deploy and maintain Huawei OptiX equipment.

Features:

- Easy

- Powerful

What is a command line?What is a command line?

Page 8: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 8HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Application of command line versions Application of command line versions

Version Application

V3.0 Equipment of earlier versions

V4.0

OptiX 155/622, OptiX OSN 2500

OptiX 155H, OptiX 155/622H (V200)

OptiX Metro 3000

V5.0OptiX Metro 100/200/500/1050, OptiX 155/622H (V300), OptiX 10GV2, OptiX

NG-SDH, OptiX OSN 9500

NavigatorCmdtermCmdclient

Types of command line software Types of command line software

Page 9: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 9HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Runs on Windows 98/2000/XP OS.

Inputs and outputs command lines and issues a batch file.

Loads NE software and board software.

Records inputs and outputs automatically.

Download the Navigator at http://support.huawei.com.

Location:Software > Version Software > Optical Network Product Line > Optical

Network Tools > Navigator

The Navigator of any version between V5.6 and V6.2 is recommended.

NavigatorNavigator

Page 10: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 10HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Navigator functionsNavigator functions

Inputs and outputs command lines.

Issues a batch file.

Upgrades software of the SCC and other boards.

Saves results automatically.Navigator window

Page 11: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 11HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Runs on the UNIX OS.Inputs and outputs command lines and issues a batch file.Does not load NE software or board software.The cmdterm is self-contained in the T2000. By default, the cmdterm is in

the path \T2000\server\Tool\.

CmdtermCmdterm

%cmdterm

Page 12: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 12HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Self-contained software of the T2000

Based on the T2000 server

Placed in the path \T2000\cmdclient\ by default

Applicable to remote maintenance

CmdclientCmdclient

Page 13: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 13HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Cmdclient windowCmdclient window

Input a command here.

Page 14: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 14HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Start the T2000.

Choose System > Security Management.

The Remote Maintenance User Management window is displayed.

Set the remote maintenance access license.

− Enable the remote maintenance user, remote.

− Set the password, operation rights, and validity period.

Run the cmdclient.exe in the \T2000\cmdclient\ path and log in to the cmdclient.

Compared with the Navigator and cmdterm, the cmdclient has the following features:

− Is under the control of the T2000 server.

− Can create and edit a remote maintenance report.

− Cannot download software of the SCC and other boards.

Running the cRunning the cmdclientmdclient

Lenovo User
界面元素,待确认。
Lenovo User
界面元素,待确认
Lenovo User
界面内容,待确认
Lenovo User
界面内容,待确认
Page 15: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 15HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Format of a command line of version VFormat of a command line of version V5.05.0

[#neid]:command[:[para_block:] ... [:para_block]]

neid: ID of the NE to run the command command: command words para_block: parameter block. Each parameter block has one or more assignments.

Page 16: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 16HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

Syntax rules of a command lineSyntax rules of a command line

Start of command: ":" (colon)

End of command: ";" (semicolon)

Parameter block separator: ":" (colon)

Parameter separator: "," (comma)

AND: "&"

To: "&&"

Shielding: "//"

Page 17: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 17HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Overview of Command Lines

:module-operation-operation object:parameter block,…;

Module• cfg: a configuration command• alm: an alarm command• per: a performance monitoring

command• sm: a security management

command• cm: a communication

management command• dbms: a database

management system command

• sys: a system command

Operation• get: to query an object• add: to add an object• set: to set an object• del: to delete an object• reset: to reset an object

Example: alm-get-curdata:0,0;

Command formatCommand format

Page 18: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 18HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Command Line Know-How

To query the format of a command, add /? next to the command words.

For example, :alm-get-curdata/?

To query all command words available for the current NE, run the following command:

:help

To retrieve data by keywords, run a command in the following format:

For example, :cfg or :cfg-get

Useful operationsUseful operations

Page 19: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 19HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Chapter 1 Overview of Command Lines

Chapter 2 Developing a Batch FileChapter 2 Developing a Batch File

Chapter 3 Common Commands

Page 20: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 20HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File Format

1. #1:login:"szhw","nesoft"; //The user name must be szhw.2. :per-set-endtime:15m,1990@0@0@0@0@0;

:per-set-endtime:24h,1990@0@0@0@0@0;3. :cfg-init-all;4. :cfg-set-devicetype:OptiXOsn3500,standard; //case-sensitive

:cfg-set-nename:64,"OSN 3500 example";

5. :cfg-add-board:9&10,ssn1gxcsa:1&2,ssn1pq1:16&15,ssn1sep;:cfg-add-board:17&18,ssn1nscc:8&11,ssn2sl64;:cfg-add-board:19&20,ssn1d75s:33,ssn1eu04:35,ssn1tsb4;//To add interface boards

6. //Clock configuration:cfg-set-synclass:9,3,0x0801,0x0b01,0xf101;

Page 21: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 21HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File Format7. //Orderwire configuration

:cfg-set-telnum:37,1,101; //To set an addressing call number

:cfg-set-meetnum:37,999; //To set a conference call number

:cfg-set-reqtime:37,5; //To set call-waiting time

:cfg-set-lineused:37,8,1,used; //To set the optical interface for the order wire service

:cfg-set-meetlineused:37,8,1,used; //To set the optical interface for the conference call

8. //Service configuration

:cfg-add-xc:0,15,1,1,0,8,1,1,0,vc4;

:cfg-add-xc:0,8,1,1,0,15,1,1,0,vc4;

:cfg-add-xc:0,2,1&&32,0,0,8,1,2,1&&32,vc12;

:cfg-add-xc:0,8,1,2,1&&32,2,1&&32,0,0,vc12;

9. :cfg-verify;

Page 22: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 22HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

In V5.0, the command line software rejects the user and returns

NSERR_SM_LOGIN_ALREADY when szhw already logs in to the NE.

To forcedly log in, run the following command:

#1:lognew:"szhw","nesoft";

NOTE

1. To log in to an NE

#1:login:"szhw","nesoft";

Page 23: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 23HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File2. To end performance monitoring

:per-set-endtime:15m,1990@0@0@0@0@0;

:per-set-endtime:24h,1990@0@0@0@0@0;

Function:

These commands end performance monitoring and ensure that configuration rate and data are properly sent to an NE.

Parameter description: 15m: Performance monitoring at the period of 15 minutes 24h: Performance monitoring at the period of 24 hours 1990@0@0@0@0@0: End time of performance monitoring. End performance monit

oring as required. To end performance monitoring immediately, set the end time to 19

90@0@0@0@0@0.

Page 24: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 24HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

To initialize an NE

:cfg-init-all;

Function:This command initializes an NE to clear all original data from the NE. In this way, the original data does not affect the coming configurations.Initialize the NE before you configure an NE.

3.

Page 25: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 25HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

To set NE parameters

:cfg-set-devicetype:OptiXOsn3500,standard; //case-senstive

:cfg-set-nename:64,“OSN 3500 example”; //The assignment 64 indicates

the length of the NE name.

:cfg-set-nepositon:“1109 room”; //This command is optional.

4.

Page 26: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 26HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

To add boards

:cfg-add-board:9&10,ssn1gxcsa:1&2&3,ssn1pq1;

:cfg-add-board:15&16,ssn1sep:8&11,ssn2sl64;

:cfg-add-board:19&&22,ssn1d75s:33,ssn1eu04:35,ssn1tsb4;

5.

Notes:1. Enter proper slot numbers and board names. 2. Precede a board name with ssn1 or ssn2 to indicate whether the board is in

series N1 or N2. For example, ssn1gxcsa. For details, see the board number.

Page 27: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 27HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File Precautions:

The following boards need to be added:

- Line boards

- Tributary boards

- SCC

- Ethernet boards

- Interface boards

- Optical amplifier boards

The active SCC is created by default and cannot be deleted. The standby SCC can be manually added or deleted.

An interface board can be added only when its mapping processing board is added.

A logically added board is in one of the following states:

- Adding

- Active

- Deleting

A board is successfully added or deleted only when the addition or deletion is successfully verified.

By default, the PIU, FAN, and AUX/SAP boards are automatically added rather than manually installed.

The CXL1/4/16 boards create logical functional units by logical slot.

Page 28: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 28HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

To set clock parameters:cfg-set-synclass:Bid,SyncNum,Sync1,Sync2,…;

For example,

:cfg-set-synclass:9,4,0xf001,0x0801,0x0b01,0xf101;

Parameter Description

BidID of the cross-connect clock board

Value range: 9 or 10

SyncNum Number of clock sources

Sync1/Sync2 Number of a clock source

6.

Page 29: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 29HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch FileFor example,

:cfg-set-synclass:9,4,0xf001,0x0801,0x0b01,0xf101;

There are four clock sources. Each clock source is numbered in double-byte hexadecimal.

- The more significant byte indicates the ID of a line board (0x01–0x11).

- The less significant byte indicates the number of an optical interface. The optical interfaces

are numbered from 1 on. The clock sources are numbered as follows:

- External clock source 1 is numbered 0xf001.

- External clock source 2 is numbered 0xf002.

- The internal clock source is numbered 0xf101.

Notes: Ensure that each line board indicated by the more significant byte is already installed. End the clock source priority table with the internal clock source.

Page 30: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 30HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

To set orderwire parameters

:cfg-set-telnum:37,1,101; //To set an addressing call number:cfg-set-meetnum:37,999; //To set a conference call number:cfg-set-tellen:37,3; //To set the length of a telephone number:cfg-set-reqtime:37,5; //To set call-waiting time:cfg-set-lineused:37,8,1,used; //To set the optical interface for the order wire service:cfg-set-meetlineused:37,8,1,used; //To set the optical interface for the conference call

Notes:1. Ensure that each board indicated by the commands is already installed.2. Set the optical interface for the addressing call and that for the

conference call separately.3. Keep the optical interface for the conference call from a loop.

7.

Page 31: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 31HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

To add service connections

:cfg-add-xc:0,15,1,1,0,8,1,1,0,vc4;

:cfg-add-xc:0,8,1,1,0,15,1,1,0,vc4;

:cfg-add-xc:0,2,1&&32,0,0,8,1,2,1&&32,vc12;

:cfg-add-xc:0,8,1,2,1&&32,2,1&&32,0,0,vc12;

8.

NOTE1. Add bidirectional service connections in pairs.2. Precede each command with comments.3. In the case of a service terminated at the local site — “//local site

– peer site”4. In the case of a pass-through service — “//source site – sink site

pass through”

To add a VC4 service connection, which runs from VC4 1 on optical interface 1 of slot 15 (source) to VC4 1 on optical interface 1 of slot 8 (sink)

Page 32: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 32HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Batch File

9. To verify and issue configurations

:cfg-verify;

Function:This command enables the SCC to verify configurations and physical situations. If the verification succeeds, the SCC saves the configurations and notifies the other boards about starting by the configurations. Without the command, the SCC does not issue the configurations to the other boards.

Page 33: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 33HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

To query the state of an NE and to check whether it runs properly

:cfg-get-nestate;

Function:This command checks whether configurations are successfully issued. If the NE is in the running state, the configurations are successfully issued. If the NE is in the installing state, the configurations fail to be delivered.

Batch File

10.

Page 34: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 34HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

To back up the NE database, that is, NE configurations manually

:dbms-copy-all:drdb,fdb0;

:dbms-copy-all:drdb,fdb1;

Function:

These commands prevent fdb0 and fdb1 from being lost due to restart.

Batch File

11.

Page 35: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 35HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Question

Explain the following statements:#1:lognew:"szhw","nesoft";:per-set-endtime:15m,1990@0@0@0@0@0;:per-set-endtime:24h,1990@0@0@0@0@0;:cfg-init-all;:cfg-set-devicetype:OptiXOsn3500,standard;:cfg-set-nename:64,"NE1";:cfg-add-board:9&10,ssn1gxcsa:1,ssn1sep1:7,ssn1sl16:17&18,ssn1nscc;:cfg-set-synclass:9,1,0xf101;:cfg-set-telnum:37,1,101; :cfg-set-meetnum:37,999; :cfg-set-reqtime:37,5;:cfg-set-lineused:37,7,1,used; :cfg-set-meetlineused:37,7,1,used; :cfg-add-xc:0,7,1,1,0,1,1,1,0,vc4;:cfg-add-xc:0,1,1,1,0,7,1,1,0,vc4;:cfg-verify;

Page 36: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 36HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Chapter 1 Overview of Command Lines

Chapter 2 Developing a Batch File

Chapter 3 Common CommandsChapter 3 Common Commands

Page 37: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 37HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

The add commands adds data.The set command sets data. The get command queries data.The del command deletes data.

Example::cfg-get-nestate;//To query the state of an NEAfter verification, an NE must be in the running state rather than in the installing state.

:cfg-get-xc:0,0;//To query all current cross-connections

:cfg-get-xc:0,5; //To query all cross-connections terminated at slot 5

Configuration queryConfiguration query

Page 38: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 38HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

:cfg-get-devicetype//To query the type of an NE

:date(:set-date:2000-2-13)//To query the date of an NE

:time(:set-time:13*00*11)//To query the time of an NE

:cfg-get-phybd//To query the physical board information

:cfg-get-bdversion:Bid//To query the version of a board

:cfg-get-bdverinfo:Bid//To query the version information of a board

Other queriesOther queries

Page 39: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 39HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

Alarm queryAlarm query

To query a current alarm

alm-get-curdata:para1,para2;

Parameter description:

para1: ID of a board. To query all boards, set this parameter to 0. para2: ID of an event. To query all events, set this parameter to 0.

Example::alm-get-curdata:0,0;//To query all current alarms reported by all boards

:alm-get-curdata:11,0;//To query all current alarms reported by board 11.

Page 40: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 40HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

To query a history alarm

:alm-get-hisdata:para1,para2;

Parameter description: para1: ID of a board. To query all boards, set this parameter to 0. para2: ID of an event. To query all events, set this parameter to 0.

Example:

:alm-get-hisdata:0,0;//To query all history alarms reported by all boards

Alarm queryAlarm query

Page 41: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 41HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

:set-date:2002-1-1;

//To set the date of an NE

:set-time:12*00*00;

//To set the time of an NE

:per-set-monevent:0,0,0,0,perall,15m,enable;

//To set a performance event to monitor

Performance monitoringPerformance monitoring

Page 42: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 42HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

:per-set-autorep:0,0,0,0,perall,15m(24h),disable; //To disable reporting a performance event automatically

:per-set-starttime:15m,2005@1@2@3@4@5;

//To set the start time of the performance monitoring at the period of 15 minutes performance

:per-set-starttime:24h,2005@1@2@3@4@5; //To set the start time of the performance monitoring at the period of 24 hours

Performance monitoringPerformance monitoring

Page 43: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 43HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

:login:"zhang","pass_word";

//To log in to an NE as zhang

:lognew:"zhang","pass_word";

//To forcedly log in to an NE as zhang

:sm-add-user:"user1","my_pass","every",enable;

//To add a user

User managementUser management

Page 44: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 44HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

:sm-get-alluser;

//To query all users

:sm-get-curuser;//To query the current user

:logout;

//To log out of an NE

User managementUser management

Page 45: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 45HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

:cm-set-lanautoecc:open;//To automatically extend an ECC

:cm-get-eccroute;//To query an ECC route

:cm-get-chanerror;//To query an ECC error

:cm-get-bdinfo;//To query ECC status on an optical interface of an optical interface board

:cm-get-fiberport:bid,portnum;//To query the state of an optical interface in an optical interface board, including DCC rate

ECC commandECC command

Page 46: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 46HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Common Commands

:cfg-reset-board:Bid, resetmode

Parameter description: Bid: ID of a board resetmode: Mode of reset

- Hard, a cold reset- Soft, a warm reset

NOTE A cold reset is thorough but interrupts services. A warm reset protects services from interruption but is not thorough.

Board resetBoard reset

:reset;

NE resetNE reset

Query about NE software versionQuery about NE software version:sys-get-nesoftver;//To query the software version of an NE

Page 47: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Page 47HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Questions

What does a command line configuration file consist of?

In addition to the configuration commands, what commands are commonly used?

Page 48: 35344695 Huawei OptiX OSN Equipment Command Line Introduction 20080628 A

Thanks!

www.huawei.com