A R C H I T E C T U R A L D E T A I L F I L E REV.3/05 24-1 Narroline ® Gliding Patio Door Contents Narroline ® Gliding Patio Door Basic Unit Details ......................................................... 24-2 Options / Accessories Ramped Sill Insert - Interior and Exterior ................ 24-4 Andersen ® Grilles.................................................... 24-5 Anchoring Methods ....................................................... 24-6 Joining Details .............................................................. 24-7 Suggested Product Applications .................................... 24-8 • 20/10 year limited warranty, fully transferable, non-prorated • Dual pane insulating glass, with Low-E or Low-E Sun available as an upgrade • White, Sandtone or Terratone ® color low maintenance exteriors • Smooth, easy operation • Narrow profiles for larger glass area • Natural pine interiors
10
Embed
200 Series Narroline Gliding Patio Doors - Architectural ... · for Professionals, in Andersen Window Studio® software, and by visiting andersenwindows.com. Combination designs should
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
A R C H I T E C T U R A L D E T A I L F I L ER E V . 3 / 0 5 24-1
N a r r o l i n e® G l i d i n g P a t i o D o o r
Contents
Narroline® Gliding Patio Door
Basic Unit Details ......................................................... 24-2
Options / Accessories
Ramped Sill Insert - Interior and Exterior ................ 24-4
Patio door unit is secured in opening using threaded fasteners through the jamb (the installation flange itself cannot support the door).
Installation flange
4-9/
16"
(116
)
Exterior sheathing
Fastener belowand above lock
Threaded masonryfastener below and above lock
Installationflange removed
Installation flangein reverse position.
Fastener belowand above lock
4-3/
16"
(106
)
A R C H I T E C T U R A L D E T A I L F I L ER E V . 3 / 0 5 24-7
N a r r o l i n e® G l i d i n g P a t i o D o o r
Andersen® Joining MaterialsScale 3" = 1'-0" (1:4)
Joining Details
2" Support Mullion
2-1/2"(64)
Andersen®Joining block
4-1/2" (114)1-5/16"
(33)
Elliptical Unit
Narroline® Patio Door Unit
Unit
Dim
ensi
on
3/8"(10) 6-3/4"
(171)
Unit
Dim
ensi
on
Over
all R
ough
Ope
ning
Hei
ght
Over
all U
nit D
imen
sion
Hei
ght
OptionalAndersen® wood casing
Optional Andersen® trim strip
Andersen®arch casing
Structureby others
Optional Andersen®2" support mullionwood filler
Optional Andersen®2" support mulliontrim strip setin continuous bead of sealant each side
2" (51)
2" (51)1-3/4" (44) 1-3/8" (35)
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
Andersen® LVL Reinforced Mullion
1-3/8" (35)1-3/8" (35)
3/4" (19)
3/4" (19)
OptionalAndersen®reinforced LVL joining strip
OptionalAndersen®wood casing
Trim strip setin continuous bead of sealant each side
Non-Reinforced Transom
A R C H I T E C T U R A L D E T A I L F I L E R E V . 3 / 0 524-8
N a r r o l i n e® G l i d i n g P a t i o D o o r
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionBrick Veneer / 2 x 6 Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including
the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the
perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation
flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L ER E V . 3 / 0 5 24-9
N a r r o l i n e® G l i d i n g P a t i o D o o r
Wall Types
Suggested Product Applications
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionStucco / Concrete Masonr y Unit (CMU) Inset Door
3/8"(10)
Unit
Dim
.W
idth
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Optional Andersen®
insectscreen
Optional Andersen®
auxiliarycasing
Optional Andersen®
oak or maple threshold
Head
Jamb
Sill
3/8"(10)
Unit
Dim
.W
idth
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1-3/16" (30)
Installationflange at head and jambs
Optional Andersen®
insect screen
Optional Andersen®
auxiliary casing
Optional Andersen®
oak or maplethreshold
Head
Jamb
Sill
Scale 1-1/2" = 1'-0" (1:8)
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the
perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E R E V . 3 / 0 524-10
N a r r o l i n e® G l i d i n g P a t i o D o o r
Scale 1-1/2" = 1'-0" (1:8)
Vertical SectionExisting Masonr y Wall
Vertical SectionExisting Stud Wall
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
3/8"(10)
Unit
Dim
.W
idth
OptionalAndersen®
insect screen
OptionalAndersen®
oak or maplethreshold
OptionalAndersen® vinyl trim board
OptionalAndersen®
rigid vinyl3/4" (19) "h" channel
Existing frame wall
Installationflange at headand jambs
OptionalAndersen®
metal sill support
Head
Jamb
Sill
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
3/8"(10)
Unit
Dim
.W
idth
OptionalAndersen®
vinyl trimboard
Optional Andersen®
rigid vinyl3/4" (19) "h" channel
Installationflange at headand jambs
OptionalAndersen®
insect screen
OptionalAndersen® oak or maplethreshold
Head
Jamb
Sill
Wall Types
Suggested Product Applications
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the
perimeter of the window.